1*724365f7Ssethg# 2*724365f7Ssethg# Copyright 2006 Sun Microsystems, Inc. All rights reserved. 3*724365f7Ssethg# Use is subject to license terms. 4*724365f7Ssethg# 5*724365f7Ssethg# CDDL HEADER START 6*724365f7Ssethg# 7*724365f7Ssethg# The contents of this file are subject to the terms of the 8*724365f7Ssethg# Common Development and Distribution License (the "License"). 9*724365f7Ssethg# You may not use this file except in compliance with the License. 10*724365f7Ssethg# 11*724365f7Ssethg# You can obtain a copy of the license at usr/src/OPENSOLARIS.LICENSE 12*724365f7Ssethg# or http://www.opensolaris.org/os/licensing. 13*724365f7Ssethg# See the License for the specific language governing permissions 14*724365f7Ssethg# and limitations under the License. 15*724365f7Ssethg# 16*724365f7Ssethg# When distributing Covered Code, include this CDDL HEADER in each 17*724365f7Ssethg# file and include the License file at usr/src/OPENSOLARIS.LICENSE. 18*724365f7Ssethg# If applicable, add the following below this CDDL HEADER, with the 19*724365f7Ssethg# fields enclosed by brackets "[]" replaced with your own identifying 20*724365f7Ssethg# information: Portions Copyright [yyyy] [name of copyright owner] 21*724365f7Ssethg# 22*724365f7Ssethg# CDDL HEADER END 23*724365f7Ssethg# 24*724365f7Ssethg#ident "%Z%%M% %I% %E% SMI" 25*724365f7Ssethg# 26*724365f7Ssethg# DO NOT EDIT -- this file is generated by the Event Registry. 27*724365f7Ssethg# 28*724365f7Ssethg# 29*724365f7Ssethg# code: DISK-8000-0X 30*724365f7Ssethg# keys: fault.io.disk.predictive-failure 31*724365f7Ssethg# 32*724365f7Ssethgmsgid "DISK-8000-0X.type" 33*724365f7Ssethgmsgstr "Fault" 34*724365f7Ssethgmsgid "DISK-8000-0X.severity" 35*724365f7Ssethgmsgstr "Major" 36*724365f7Ssethgmsgid "DISK-8000-0X.description" 37*724365f7Ssethgmsgstr "SMART health-monitoring firmware reported that a disk\nfailure is imminent.\n Refer to %s for more information." 38*724365f7Ssethgmsgid "DISK-8000-0X.response" 39*724365f7Ssethgmsgstr "None.\n" 40*724365f7Ssethgmsgid "DISK-8000-0X.impact" 41*724365f7Ssethgmsgstr "It is likely that the continued operation of\nthis disk will result in data loss.\n" 42*724365f7Ssethgmsgid "DISK-8000-0X.action" 43*724365f7Ssethgmsgstr "Schedule a repair procedure to replace the affected disk.\nUse fmdump -v -u <EVENT_ID> to identify the disk.\n" 44*724365f7Ssethg# 45*724365f7Ssethg# code: DISK-8000-12 46*724365f7Ssethg# keys: fault.io.disk.over-temperature 47*724365f7Ssethg# 48*724365f7Ssethgmsgid "DISK-8000-12.type" 49*724365f7Ssethgmsgstr "Fault" 50*724365f7Ssethgmsgid "DISK-8000-12.severity" 51*724365f7Ssethgmsgstr "Major" 52*724365f7Ssethgmsgid "DISK-8000-12.description" 53*724365f7Ssethgmsgstr "A disk's temperature exceeded the limits established by\nits manufacturer.\n Refer to %s for more information." 54*724365f7Ssethgmsgid "DISK-8000-12.response" 55*724365f7Ssethgmsgstr "None.\n" 56*724365f7Ssethgmsgid "DISK-8000-12.impact" 57*724365f7Ssethgmsgstr "Performance degradation is likely and continued disk operation\nbeyond the temperature threshold can result in disk\ndamage and potential data loss.\n" 58*724365f7Ssethgmsgid "DISK-8000-12.action" 59*724365f7Ssethgmsgstr "Ensure that the system is properly cooled, that all fans are\nfunctional, and that there are no obstructions of airflow to the affected\ndisk.\n" 60*724365f7Ssethg# 61*724365f7Ssethg# code: DISK-8000-2J 62*724365f7Ssethg# keys: fault.io.disk.self-test-failure 63*724365f7Ssethg# 64*724365f7Ssethgmsgid "DISK-8000-2J.type" 65*724365f7Ssethgmsgstr "Fault" 66*724365f7Ssethgmsgid "DISK-8000-2J.severity" 67*724365f7Ssethgmsgstr "Critical" 68*724365f7Ssethgmsgid "DISK-8000-2J.description" 69*724365f7Ssethgmsgstr "One or more disk self tests failed.\n Refer to %s for more information." 70*724365f7Ssethgmsgid "DISK-8000-2J.response" 71*724365f7Ssethgmsgstr "None.\n" 72*724365f7Ssethgmsgid "DISK-8000-2J.impact" 73*724365f7Ssethgmsgstr "The disk has failed.\n" 74*724365f7Ssethgmsgid "DISK-8000-2J.action" 75*724365f7Ssethgmsgstr "Schedule a repair procedure to replace the affected disk.\nUse fmdump -v -u <EVENT_ID> to identify the disk.\n" 76