xref: /titanic_52/usr/src/cmd/fm/dicts/DISK.po (revision 724365f7556fc4201fdb11766ebc6bd918523130)
1*724365f7Ssethg#
2*724365f7Ssethg# Copyright 2006 Sun Microsystems, Inc.  All rights reserved.
3*724365f7Ssethg# Use is subject to license terms.
4*724365f7Ssethg#
5*724365f7Ssethg# CDDL HEADER START
6*724365f7Ssethg#
7*724365f7Ssethg# The contents of this file are subject to the terms of the
8*724365f7Ssethg# Common Development and Distribution License (the "License").
9*724365f7Ssethg# You may not use this file except in compliance with the License.
10*724365f7Ssethg#
11*724365f7Ssethg# You can obtain a copy of the license at usr/src/OPENSOLARIS.LICENSE
12*724365f7Ssethg# or http://www.opensolaris.org/os/licensing.
13*724365f7Ssethg# See the License for the specific language governing permissions
14*724365f7Ssethg# and limitations under the License.
15*724365f7Ssethg#
16*724365f7Ssethg# When distributing Covered Code, include this CDDL HEADER in each
17*724365f7Ssethg# file and include the License file at usr/src/OPENSOLARIS.LICENSE.
18*724365f7Ssethg# If applicable, add the following below this CDDL HEADER, with the
19*724365f7Ssethg# fields enclosed by brackets "[]" replaced with your own identifying
20*724365f7Ssethg# information: Portions Copyright [yyyy] [name of copyright owner]
21*724365f7Ssethg#
22*724365f7Ssethg# CDDL HEADER END
23*724365f7Ssethg#
24*724365f7Ssethg#ident	"%Z%%M%	%I%	%E% SMI"
25*724365f7Ssethg#
26*724365f7Ssethg# DO NOT EDIT -- this file is generated by the Event Registry.
27*724365f7Ssethg#
28*724365f7Ssethg#
29*724365f7Ssethg# code: DISK-8000-0X
30*724365f7Ssethg# keys: fault.io.disk.predictive-failure
31*724365f7Ssethg#
32*724365f7Ssethgmsgid "DISK-8000-0X.type"
33*724365f7Ssethgmsgstr "Fault"
34*724365f7Ssethgmsgid "DISK-8000-0X.severity"
35*724365f7Ssethgmsgstr "Major"
36*724365f7Ssethgmsgid "DISK-8000-0X.description"
37*724365f7Ssethgmsgstr "SMART health-monitoring firmware reported that a disk\nfailure is imminent.\n  Refer to %s for more information."
38*724365f7Ssethgmsgid "DISK-8000-0X.response"
39*724365f7Ssethgmsgstr "None.\n"
40*724365f7Ssethgmsgid "DISK-8000-0X.impact"
41*724365f7Ssethgmsgstr "It is likely that the continued operation of\nthis disk will result in data loss.\n"
42*724365f7Ssethgmsgid "DISK-8000-0X.action"
43*724365f7Ssethgmsgstr "Schedule a repair procedure to replace the affected disk.\nUse fmdump -v -u <EVENT_ID> to identify the disk.\n"
44*724365f7Ssethg#
45*724365f7Ssethg# code: DISK-8000-12
46*724365f7Ssethg# keys: fault.io.disk.over-temperature
47*724365f7Ssethg#
48*724365f7Ssethgmsgid "DISK-8000-12.type"
49*724365f7Ssethgmsgstr "Fault"
50*724365f7Ssethgmsgid "DISK-8000-12.severity"
51*724365f7Ssethgmsgstr "Major"
52*724365f7Ssethgmsgid "DISK-8000-12.description"
53*724365f7Ssethgmsgstr "A disk's temperature exceeded the limits established by\nits manufacturer.\n  Refer to %s for more information."
54*724365f7Ssethgmsgid "DISK-8000-12.response"
55*724365f7Ssethgmsgstr "None.\n"
56*724365f7Ssethgmsgid "DISK-8000-12.impact"
57*724365f7Ssethgmsgstr "Performance degradation is likely and continued disk operation\nbeyond the temperature threshold can result in disk\ndamage and potential data loss.\n"
58*724365f7Ssethgmsgid "DISK-8000-12.action"
59*724365f7Ssethgmsgstr "Ensure that the system is properly cooled, that all fans are\nfunctional, and that there are no obstructions of airflow to the affected\ndisk.\n"
60*724365f7Ssethg#
61*724365f7Ssethg# code: DISK-8000-2J
62*724365f7Ssethg# keys: fault.io.disk.self-test-failure
63*724365f7Ssethg#
64*724365f7Ssethgmsgid "DISK-8000-2J.type"
65*724365f7Ssethgmsgstr "Fault"
66*724365f7Ssethgmsgid "DISK-8000-2J.severity"
67*724365f7Ssethgmsgstr "Critical"
68*724365f7Ssethgmsgid "DISK-8000-2J.description"
69*724365f7Ssethgmsgstr "One or more disk self tests failed.\n  Refer to %s for more information."
70*724365f7Ssethgmsgid "DISK-8000-2J.response"
71*724365f7Ssethgmsgstr "None.\n"
72*724365f7Ssethgmsgid "DISK-8000-2J.impact"
73*724365f7Ssethgmsgstr "The disk has failed.\n"
74*724365f7Ssethgmsgid "DISK-8000-2J.action"
75*724365f7Ssethgmsgstr "Schedule a repair procedure to replace the affected disk.\nUse fmdump -v -u <EVENT_ID> to identify the disk.\n"