1724365f7Ssethg# 2*9e1c849eSDavid Zhang - Sun Microsystems - Beijing China# Copyright 2008 Sun Microsystems, Inc. All rights reserved. 3724365f7Ssethg# Use is subject to license terms. 4724365f7Ssethg# 5724365f7Ssethg# CDDL HEADER START 6724365f7Ssethg# 7724365f7Ssethg# The contents of this file are subject to the terms of the 8724365f7Ssethg# Common Development and Distribution License (the "License"). 9724365f7Ssethg# You may not use this file except in compliance with the License. 10724365f7Ssethg# 11724365f7Ssethg# You can obtain a copy of the license at usr/src/OPENSOLARIS.LICENSE 12724365f7Ssethg# or http://www.opensolaris.org/os/licensing. 13724365f7Ssethg# See the License for the specific language governing permissions 14724365f7Ssethg# and limitations under the License. 15724365f7Ssethg# 16724365f7Ssethg# When distributing Covered Code, include this CDDL HEADER in each 17724365f7Ssethg# file and include the License file at usr/src/OPENSOLARIS.LICENSE. 18724365f7Ssethg# If applicable, add the following below this CDDL HEADER, with the 19724365f7Ssethg# fields enclosed by brackets "[]" replaced with your own identifying 20724365f7Ssethg# information: Portions Copyright [yyyy] [name of copyright owner] 21724365f7Ssethg# 22724365f7Ssethg# CDDL HEADER END 23724365f7Ssethg# 24724365f7Ssethg# 25724365f7Ssethg# DO NOT EDIT -- this file is generated by the Event Registry. 26724365f7Ssethg# 27724365f7Ssethg# 28724365f7Ssethg# code: DISK-8000-0X 29724365f7Ssethg# keys: fault.io.disk.predictive-failure 30724365f7Ssethg# 31724365f7Ssethgmsgid "DISK-8000-0X.type" 32724365f7Ssethgmsgstr "Fault" 33724365f7Ssethgmsgid "DISK-8000-0X.severity" 34724365f7Ssethgmsgstr "Major" 35724365f7Ssethgmsgid "DISK-8000-0X.description" 36724365f7Ssethgmsgstr "SMART health-monitoring firmware reported that a disk\nfailure is imminent.\n Refer to %s for more information." 37724365f7Ssethgmsgid "DISK-8000-0X.response" 38724365f7Ssethgmsgstr "None.\n" 39724365f7Ssethgmsgid "DISK-8000-0X.impact" 40724365f7Ssethgmsgstr "It is likely that the continued operation of\nthis disk will result in data loss.\n" 41724365f7Ssethgmsgid "DISK-8000-0X.action" 42724365f7Ssethgmsgstr "Schedule a repair procedure to replace the affected disk.\nUse fmdump -v -u <EVENT_ID> to identify the disk.\n" 43724365f7Ssethg# 44724365f7Ssethg# code: DISK-8000-12 45724365f7Ssethg# keys: fault.io.disk.over-temperature 46724365f7Ssethg# 47724365f7Ssethgmsgid "DISK-8000-12.type" 48724365f7Ssethgmsgstr "Fault" 49724365f7Ssethgmsgid "DISK-8000-12.severity" 50724365f7Ssethgmsgstr "Major" 51724365f7Ssethgmsgid "DISK-8000-12.description" 52724365f7Ssethgmsgstr "A disk's temperature exceeded the limits established by\nits manufacturer.\n Refer to %s for more information." 53724365f7Ssethgmsgid "DISK-8000-12.response" 54724365f7Ssethgmsgstr "None.\n" 55724365f7Ssethgmsgid "DISK-8000-12.impact" 56724365f7Ssethgmsgstr "Performance degradation is likely and continued disk operation\nbeyond the temperature threshold can result in disk\ndamage and potential data loss.\n" 57724365f7Ssethgmsgid "DISK-8000-12.action" 58724365f7Ssethgmsgstr "Ensure that the system is properly cooled, that all fans are\nfunctional, and that there are no obstructions of airflow to the affected\ndisk.\n" 59724365f7Ssethg# 60724365f7Ssethg# code: DISK-8000-2J 61724365f7Ssethg# keys: fault.io.disk.self-test-failure 62724365f7Ssethg# 63724365f7Ssethgmsgid "DISK-8000-2J.type" 64724365f7Ssethgmsgstr "Fault" 65724365f7Ssethgmsgid "DISK-8000-2J.severity" 66724365f7Ssethgmsgstr "Critical" 67724365f7Ssethgmsgid "DISK-8000-2J.description" 68724365f7Ssethgmsgstr "One or more disk self tests failed.\n Refer to %s for more information." 69724365f7Ssethgmsgid "DISK-8000-2J.response" 70724365f7Ssethgmsgstr "None.\n" 71724365f7Ssethgmsgid "DISK-8000-2J.impact" 72724365f7Ssethgmsgstr "The disk has failed.\n" 73724365f7Ssethgmsgid "DISK-8000-2J.action" 74724365f7Ssethgmsgstr "Schedule a repair procedure to replace the affected disk.\nUse fmdump -v -u <EVENT_ID> to identify the disk.\n" 75*9e1c849eSDavid Zhang - Sun Microsystems - Beijing China# 76*9e1c849eSDavid Zhang - Sun Microsystems - Beijing China# code: DISK-8000-3E 77*9e1c849eSDavid Zhang - Sun Microsystems - Beijing China# keys: fault.io.scsi.cmd.disk.dev.rqs.derr 78*9e1c849eSDavid Zhang - Sun Microsystems - Beijing China# 79*9e1c849eSDavid Zhang - Sun Microsystems - Beijing Chinamsgid "DISK-8000-3E.type" 80*9e1c849eSDavid Zhang - Sun Microsystems - Beijing Chinamsgstr "Fault" 81*9e1c849eSDavid Zhang - Sun Microsystems - Beijing Chinamsgid "DISK-8000-3E.severity" 82*9e1c849eSDavid Zhang - Sun Microsystems - Beijing Chinamsgstr "Critical" 83*9e1c849eSDavid Zhang - Sun Microsystems - Beijing Chinamsgid "DISK-8000-3E.description" 84*9e1c849eSDavid Zhang - Sun Microsystems - Beijing Chinamsgstr "A non-recoverable hardware failure was detected by the device while performing a command.\n Refer to %s for more information." 85*9e1c849eSDavid Zhang - Sun Microsystems - Beijing Chinamsgid "DISK-8000-3E.response" 86*9e1c849eSDavid Zhang - Sun Microsystems - Beijing Chinamsgstr "The device may be offlined or degraded.\n" 87*9e1c849eSDavid Zhang - Sun Microsystems - Beijing Chinamsgid "DISK-8000-3E.impact" 88*9e1c849eSDavid Zhang - Sun Microsystems - Beijing Chinamsgstr "The device has failed. The service may have been lost or degraded.\n" 89*9e1c849eSDavid Zhang - Sun Microsystems - Beijing Chinamsgid "DISK-8000-3E.action" 90*9e1c849eSDavid Zhang - Sun Microsystems - Beijing Chinamsgstr "Ensure that the latest drivers and patches are installed. Schedule a repair procedure to replace the affected\ndevice. Use 'fmadm faulty' to find the affected disk.\n" 91*9e1c849eSDavid Zhang - Sun Microsystems - Beijing China# 92*9e1c849eSDavid Zhang - Sun Microsystems - Beijing China# code: DISK-8000-4Q 93*9e1c849eSDavid Zhang - Sun Microsystems - Beijing China# keys: fault.io.scsi.cmd.disk.dev.rqs.merr 94*9e1c849eSDavid Zhang - Sun Microsystems - Beijing China# 95*9e1c849eSDavid Zhang - Sun Microsystems - Beijing Chinamsgid "DISK-8000-4Q.type" 96*9e1c849eSDavid Zhang - Sun Microsystems - Beijing Chinamsgstr "Fault" 97*9e1c849eSDavid Zhang - Sun Microsystems - Beijing Chinamsgid "DISK-8000-4Q.severity" 98*9e1c849eSDavid Zhang - Sun Microsystems - Beijing Chinamsgstr "Critical" 99*9e1c849eSDavid Zhang - Sun Microsystems - Beijing Chinamsgid "DISK-8000-4Q.description" 100*9e1c849eSDavid Zhang - Sun Microsystems - Beijing Chinamsgstr "The command was terminated with a non-recovered error condition that may have been caused by a flaw in the media or an error in the recorded data. \n Refer to %s for more information." 101*9e1c849eSDavid Zhang - Sun Microsystems - Beijing Chinamsgid "DISK-8000-4Q.response" 102*9e1c849eSDavid Zhang - Sun Microsystems - Beijing Chinamsgstr "The device may be offlined or degraded.\n" 103*9e1c849eSDavid Zhang - Sun Microsystems - Beijing Chinamsgid "DISK-8000-4Q.impact" 104*9e1c849eSDavid Zhang - Sun Microsystems - Beijing Chinamsgstr "It is likely that continued operation will result in data corruption, which may eventually cause the loss of service or the service degradation.\n" 105*9e1c849eSDavid Zhang - Sun Microsystems - Beijing Chinamsgid "DISK-8000-4Q.action" 106*9e1c849eSDavid Zhang - Sun Microsystems - Beijing Chinamsgstr "Schedule a repair procedure to replace the affected device. Use 'fmadm faulty' to find the affected disk.\n" 107