xref: /titanic_52/usr/src/cmd/fm/dicts/DISK.po (revision 9e1c849eae563842996c64c805047e840c75fc79)
1724365f7Ssethg#
2*9e1c849eSDavid Zhang - Sun Microsystems - Beijing China# Copyright 2008 Sun Microsystems, Inc.  All rights reserved.
3724365f7Ssethg# Use is subject to license terms.
4724365f7Ssethg#
5724365f7Ssethg# CDDL HEADER START
6724365f7Ssethg#
7724365f7Ssethg# The contents of this file are subject to the terms of the
8724365f7Ssethg# Common Development and Distribution License (the "License").
9724365f7Ssethg# You may not use this file except in compliance with the License.
10724365f7Ssethg#
11724365f7Ssethg# You can obtain a copy of the license at usr/src/OPENSOLARIS.LICENSE
12724365f7Ssethg# or http://www.opensolaris.org/os/licensing.
13724365f7Ssethg# See the License for the specific language governing permissions
14724365f7Ssethg# and limitations under the License.
15724365f7Ssethg#
16724365f7Ssethg# When distributing Covered Code, include this CDDL HEADER in each
17724365f7Ssethg# file and include the License file at usr/src/OPENSOLARIS.LICENSE.
18724365f7Ssethg# If applicable, add the following below this CDDL HEADER, with the
19724365f7Ssethg# fields enclosed by brackets "[]" replaced with your own identifying
20724365f7Ssethg# information: Portions Copyright [yyyy] [name of copyright owner]
21724365f7Ssethg#
22724365f7Ssethg# CDDL HEADER END
23724365f7Ssethg#
24724365f7Ssethg#
25724365f7Ssethg# DO NOT EDIT -- this file is generated by the Event Registry.
26724365f7Ssethg#
27724365f7Ssethg#
28724365f7Ssethg# code: DISK-8000-0X
29724365f7Ssethg# keys: fault.io.disk.predictive-failure
30724365f7Ssethg#
31724365f7Ssethgmsgid "DISK-8000-0X.type"
32724365f7Ssethgmsgstr "Fault"
33724365f7Ssethgmsgid "DISK-8000-0X.severity"
34724365f7Ssethgmsgstr "Major"
35724365f7Ssethgmsgid "DISK-8000-0X.description"
36724365f7Ssethgmsgstr "SMART health-monitoring firmware reported that a disk\nfailure is imminent.\n  Refer to %s for more information."
37724365f7Ssethgmsgid "DISK-8000-0X.response"
38724365f7Ssethgmsgstr "None.\n"
39724365f7Ssethgmsgid "DISK-8000-0X.impact"
40724365f7Ssethgmsgstr "It is likely that the continued operation of\nthis disk will result in data loss.\n"
41724365f7Ssethgmsgid "DISK-8000-0X.action"
42724365f7Ssethgmsgstr "Schedule a repair procedure to replace the affected disk.\nUse fmdump -v -u <EVENT_ID> to identify the disk.\n"
43724365f7Ssethg#
44724365f7Ssethg# code: DISK-8000-12
45724365f7Ssethg# keys: fault.io.disk.over-temperature
46724365f7Ssethg#
47724365f7Ssethgmsgid "DISK-8000-12.type"
48724365f7Ssethgmsgstr "Fault"
49724365f7Ssethgmsgid "DISK-8000-12.severity"
50724365f7Ssethgmsgstr "Major"
51724365f7Ssethgmsgid "DISK-8000-12.description"
52724365f7Ssethgmsgstr "A disk's temperature exceeded the limits established by\nits manufacturer.\n  Refer to %s for more information."
53724365f7Ssethgmsgid "DISK-8000-12.response"
54724365f7Ssethgmsgstr "None.\n"
55724365f7Ssethgmsgid "DISK-8000-12.impact"
56724365f7Ssethgmsgstr "Performance degradation is likely and continued disk operation\nbeyond the temperature threshold can result in disk\ndamage and potential data loss.\n"
57724365f7Ssethgmsgid "DISK-8000-12.action"
58724365f7Ssethgmsgstr "Ensure that the system is properly cooled, that all fans are\nfunctional, and that there are no obstructions of airflow to the affected\ndisk.\n"
59724365f7Ssethg#
60724365f7Ssethg# code: DISK-8000-2J
61724365f7Ssethg# keys: fault.io.disk.self-test-failure
62724365f7Ssethg#
63724365f7Ssethgmsgid "DISK-8000-2J.type"
64724365f7Ssethgmsgstr "Fault"
65724365f7Ssethgmsgid "DISK-8000-2J.severity"
66724365f7Ssethgmsgstr "Critical"
67724365f7Ssethgmsgid "DISK-8000-2J.description"
68724365f7Ssethgmsgstr "One or more disk self tests failed.\n  Refer to %s for more information."
69724365f7Ssethgmsgid "DISK-8000-2J.response"
70724365f7Ssethgmsgstr "None.\n"
71724365f7Ssethgmsgid "DISK-8000-2J.impact"
72724365f7Ssethgmsgstr "The disk has failed.\n"
73724365f7Ssethgmsgid "DISK-8000-2J.action"
74724365f7Ssethgmsgstr "Schedule a repair procedure to replace the affected disk.\nUse fmdump -v -u <EVENT_ID> to identify the disk.\n"
75*9e1c849eSDavid Zhang - Sun Microsystems - Beijing China#
76*9e1c849eSDavid Zhang - Sun Microsystems - Beijing China# code: DISK-8000-3E
77*9e1c849eSDavid Zhang - Sun Microsystems - Beijing China# keys: fault.io.scsi.cmd.disk.dev.rqs.derr
78*9e1c849eSDavid Zhang - Sun Microsystems - Beijing China#
79*9e1c849eSDavid Zhang - Sun Microsystems - Beijing Chinamsgid "DISK-8000-3E.type"
80*9e1c849eSDavid Zhang - Sun Microsystems - Beijing Chinamsgstr "Fault"
81*9e1c849eSDavid Zhang - Sun Microsystems - Beijing Chinamsgid "DISK-8000-3E.severity"
82*9e1c849eSDavid Zhang - Sun Microsystems - Beijing Chinamsgstr "Critical"
83*9e1c849eSDavid Zhang - Sun Microsystems - Beijing Chinamsgid "DISK-8000-3E.description"
84*9e1c849eSDavid Zhang - Sun Microsystems - Beijing Chinamsgstr "A non-recoverable hardware failure was detected by the device while performing a command.\n  Refer to %s for more information."
85*9e1c849eSDavid Zhang - Sun Microsystems - Beijing Chinamsgid "DISK-8000-3E.response"
86*9e1c849eSDavid Zhang - Sun Microsystems - Beijing Chinamsgstr "The device may be offlined or degraded.\n"
87*9e1c849eSDavid Zhang - Sun Microsystems - Beijing Chinamsgid "DISK-8000-3E.impact"
88*9e1c849eSDavid Zhang - Sun Microsystems - Beijing Chinamsgstr "The device has failed. The service may have been lost or degraded.\n"
89*9e1c849eSDavid Zhang - Sun Microsystems - Beijing Chinamsgid "DISK-8000-3E.action"
90*9e1c849eSDavid Zhang - Sun Microsystems - Beijing Chinamsgstr "Ensure that the latest drivers and patches are installed. Schedule a repair procedure to replace the affected\ndevice. Use 'fmadm faulty' to find the affected disk.\n"
91*9e1c849eSDavid Zhang - Sun Microsystems - Beijing China#
92*9e1c849eSDavid Zhang - Sun Microsystems - Beijing China# code: DISK-8000-4Q
93*9e1c849eSDavid Zhang - Sun Microsystems - Beijing China# keys: fault.io.scsi.cmd.disk.dev.rqs.merr
94*9e1c849eSDavid Zhang - Sun Microsystems - Beijing China#
95*9e1c849eSDavid Zhang - Sun Microsystems - Beijing Chinamsgid "DISK-8000-4Q.type"
96*9e1c849eSDavid Zhang - Sun Microsystems - Beijing Chinamsgstr "Fault"
97*9e1c849eSDavid Zhang - Sun Microsystems - Beijing Chinamsgid "DISK-8000-4Q.severity"
98*9e1c849eSDavid Zhang - Sun Microsystems - Beijing Chinamsgstr "Critical"
99*9e1c849eSDavid Zhang - Sun Microsystems - Beijing Chinamsgid "DISK-8000-4Q.description"
100*9e1c849eSDavid Zhang - Sun Microsystems - Beijing Chinamsgstr "The command was terminated with a non-recovered error condition that may have been caused by a flaw in the media or an error in the recorded data. \n  Refer to %s for more information."
101*9e1c849eSDavid Zhang - Sun Microsystems - Beijing Chinamsgid "DISK-8000-4Q.response"
102*9e1c849eSDavid Zhang - Sun Microsystems - Beijing Chinamsgstr "The device may be offlined or degraded.\n"
103*9e1c849eSDavid Zhang - Sun Microsystems - Beijing Chinamsgid "DISK-8000-4Q.impact"
104*9e1c849eSDavid Zhang - Sun Microsystems - Beijing Chinamsgstr "It is likely that continued operation will result in data corruption, which may eventually cause the loss of service or the service degradation.\n"
105*9e1c849eSDavid Zhang - Sun Microsystems - Beijing Chinamsgid "DISK-8000-4Q.action"
106*9e1c849eSDavid Zhang - Sun Microsystems - Beijing Chinamsgstr "Schedule a repair procedure to replace the affected device. Use 'fmadm faulty' to find the affected disk.\n"
107