xref: /titanic_51/usr/src/pkg/manifests/driver-storage-lsimega.mf (revision 005d3feb53a9a10272d4a24b03991575d6a9bcb3)
1#
2# CDDL HEADER START
3#
4# The contents of this file are subject to the terms of the
5# Common Development and Distribution License (the "License").
6# You may not use this file except in compliance with the License.
7#
8# You can obtain a copy of the license at usr/src/OPENSOLARIS.LICENSE
9# or http://www.opensolaris.org/os/licensing.
10# See the License for the specific language governing permissions
11# and limitations under the License.
12#
13# When distributing Covered Code, include this CDDL HEADER in each
14# file and include the License file at usr/src/OPENSOLARIS.LICENSE.
15# If applicable, add the following below this CDDL HEADER, with the
16# fields enclosed by brackets "[]" replaced with your own identifying
17# information: Portions Copyright [yyyy] [name of copyright owner]
18#
19# CDDL HEADER END
20#
21
22#
23# Copyright 2010 Sun Microsystems, Inc.  All rights reserved.
24# Use is subject to license terms.
25#
26
27#
28# This package will install successfully into any zone, global or
29# non-global.  The files, directories, links, and hardlinks, however,
30# will only be installed into the global zone.
31#
32<include hollow_zone_pkg>
33set name=pkg.fmri value=pkg:/driver/storage/lsimega@$(PKGVERS)
34set name=pkg.description value="LSI Hardware RAID HBA Driver"
35set name=pkg.summary value="LSI Hardware RAID HBA Driver"
36set name=info.classification value=org.opensolaris.category.2008:Drivers/Storage
37set name=variant.arch value=i386
38set name=variant.opensolaris.zone value=global value=nonglobal
39dir path=kernel group=sys
40dir path=kernel/drv group=sys
41dir path=kernel/drv/$(ARCH64) group=sys
42driver name=lsimega class=scsi \
43    alias=pci1000,1960 \
44    alias=pci1000,407 \
45    alias=pci1000,407.1000.532 \
46    alias=pci1000,408 \
47    alias=pci1000,408.1000.2 \
48    alias=pci1000,409 \
49    alias=pci1028,13
50file path=kernel/drv/$(ARCH64)/lsimega group=sys
51file path=kernel/drv/lsimega group=sys
52file path=kernel/drv/lsimega.conf group=sys reboot-needed=false
53legacy pkg=SUNWlsimega arch=$(ARCH) category=system \
54    desc="LSI Hardware RAID HBA Driver" \
55    hotline="Please contact your local service provider" \
56    name="LSI Hardware RAID HBA Driver" vendor="Sun Microsystems, Inc." \
57    version=11.11,REV=2009.11.11
58license cr_Sun license=cr_Sun
59license lic_OSBL license=lic_OSBL
60license lic_OSBL_preamble license=lic_OSBL_preamble
61