xref: /titanic_51/usr/src/man/man1m/fcinfo.1m (revision a1f661d2d1b9c9526143179014bbdd3949a90abe)
te
Copyright (c) 2009, Sun Microsystems, Inc. All Rights Reserved
The contents of this file are subject to the terms of the Common Development and Distribution License (the "License"). You may not use this file except in compliance with the License. You can obtain a copy of the license at usr/src/OPENSOLARIS.LICENSE or http://www.opensolaris.org/os/licensing.
See the License for the specific language governing permissions and limitations under the License. When distributing Covered Code, include this CDDL HEADER in each file and include the License file at usr/src/OPENSOLARIS.LICENSE. If applicable, add the following below this CDDL HEADER, with
the fields enclosed by brackets "[]" replaced with your own identifying information: Portions Copyright [yyyy] [name of copyright owner]
FCINFO 1M "Jul 26, 2009"
NAME
fcinfo, fcadm - Fibre Channel HBA Port Command Line Interface
SYNOPSIS

fcinfo hba-port [-lite] [HBA_port_WWN]...

fcadm hba-port [-lite] [HBA_port_WWN]...

fcinfo remote-port [-ls] [-p HBA_port_WWN]
 [REMOTE_port_WWN]...

fcadm remote-port [-ls] [-p HBA_port_WWN]
 [REMOTE_port_WWN]...

fcinfo logical-unit | lu [-v] [OS device_path]

fcadm logical-unit | lu [-v] [OS device_path]

fcadm create-npiv-port -p Virtual_Port_WWN [-n Virtual_Node_WWN]
 PhysicalPort_port_WWN

fcadm delete-npiv-port -p Virtual_Port_WWN [-n Virtual_Node_WWN]
 PhysicalPort_port_WWN

fcadm create-fcoe-port [-tf] -p Port_WWN [-n Node_WWN]
 MAC_Interface

fcadm delete-fcoe-port MAC_Interface

fcadm list-fcoe-ports MAC_Interface

fcadm force-lip Port_WWN

fcinfo [-V]

fcadm [-V]

fcinfo [-?]

fcadm [-?]
DESCRIPTION

fcinfo and fcadm are command line interfaces that collect administrative information on fibre channel host bus adapter (HBA) ports on a host. They also collect data on any fibre channel targets that might be connected to those ports in a Storage Area Network (SAN).

A port can be either in initiator mode or target mode. The same FC attribute information and remote port information are applied to both the initiator and the target modes port except that SCSI-related operations described below do not apply for the target mode port.

"SUBCOMMANDS"

The following subcommands are supported by both fcinfo and fcadm: hba-port

Lists information for the HBA port referenced by the specified HBA_port_WWN. If HBA_port_WWN is not specified, all initiator mode and target mode fibre channel HBA ports on the host will be listed.

remote-port

Lists the remote-port information for those remote ports that are specified. If no REMOTE_port_WWN is specified, all remote ports that are visible through HBA_port_WWN are listed.

logical-unit | lu

Lists the logical unit referenced by the specified device_path. If device_path is not specified, all fibre channel logical units will be listed. This subcommand applies only to the initiator mode.

The following subcommands, which administer N_Port ID Virtualization (NPIV) HBA ports, are supported only by fcadm: create-npiv-port

Create an NPIV virtual port on the specified adapter.

delete-npiv-port

Delete an NPIV virtual port. This delete only ports create by fcadm.

The following subcommands, which administer Fibre Channel over Ethernet (FCoE) ports, are supported only by fcadm: create-fcoe-port

Creates a FCoE port associated with the given MAC interface and the given Port_WWN/Node_WWN. If -p or -n is not specified, the Port WWN or Node WWN will be generated automatically. If the specified MAC interface does not support multiple unicast address, no FCoE port will be created and you receive a message indicating that you can add an -f option to force enabling promiscuous mode on the specified MAC interface to enable FCoE.

delete-fcoe-port

Deletes the FCoE port associated with the specified MAC interface.

list-fcoe-ports

List information of FCoE ports.

force-lip

Force the link to reinitialize. When issuing this subcommand on the target port side, causes a reset of the target port. When issuing it from the host port side, resets the host port. When an FC switch is connected, other FC ports in the SAN will get a RSCN (Remote State Change Notification). Furthermore, other initiators will always rediscover the port after this, and the FC login session will be established or reused. Also, I/Os will be continued. This command is disruptive to I/Os, but it is not destructive, as it does not cause any data loss.

OPTIONS

The following options are supported: -e, --fcoe

Lists the information for all FCoE ports.

-f, --fcoe-promiscuous

Used with create-fcoe-port to create an FCoE port on a MAC interface associated with a NIC that does not support multiple unicast address. Promiscuous mode will be enabled for the specified MAC interface.

-l, --linkstat

Lists the link error statistics information for the port referenced by the specified HBA_port_WWN or REMOTE_port_WWN.

-n HBA_node_WWN, --node HBA_node_WWN

When used with NPIV options, specify a virtual node WWN. If used with create-npiv-port, it can be omitted, and a random based WWN will be used. It is mandatory for delete-npiv-port. When used with create-fcoe-port subcommand, specify the node WWN for the FCoE port. It can be omitted, in which case a WWN will be generated based on the MAC address of the specified MAC interface.

-p HBA_port_WWN, --port HBA_port_WWN

Retrieve remote port information from the HBA_port_WWN of the local HBA port on the host. When used with the remote-port subcommand, the -p option is mandatory. When used with NPIV options, specify a virtual port WWN. If used with create-npiv-port, it can be omitted, and a random based WWN will be used. It is mandatory for delete-npiv-port. When used with create-fcoe-port subcommand, specify the port WWN for the FCoE port. It can be omitted, in which case a WWN will be generated based on the MAC address of the specified MAC interface.

-s, --scsi-target

Lists the SCSI target information for all remote ports the user has asked for. The -p, --port option must always be specified and must be a valid HBA port on the host. This HBA port will be used as the initiator for which to retrieve the SCSI level target information. Note that this will only function on remote port fibre channel World-Wide Names that support an FC4 type of SCSI. This option applies only to an initiator mode port.

-t [HBA_node_WWN], -target [HBA_node_WWN]

Lists the information for the port with the target mode referenced by the specified HBA_node_WWN or all target mode ports discovered in the host. When used with create-fcoe-port, create a FCoE target mode port.

-v, --verbose

When used with the logical-unit subcommand, the -v displays additional information for the logical unit, including SCSI vendor and product information and device type as well as the FC World-Wide names for the local and remote fibre channel ports to which this device is attached.

-V, --version

Displays the version information.

-?, --help

Displays the usage information.

EXAMPLES

Example 1 Listing All HBA Ports

The following command lists all initiator mode fibre channel HBA ports on the host:

# fcinfo hba-port

HBA Port WWN: 210000e08b074cb5
 Port Mode: Initiator
 OS Device Name: /dev/cfg/c1
 Manufacturer: QLogic Corp.
 Model: 375-3108-xx
 Firmware Version: 3.3.116
 FCode/BIOS Version: 1.13.08
 Serial Number: not available
 Driver Name: qlc
 Driver Version: 20070212-2.19
 Type: N-port
 State: online
 Supported Speeds: 1Gb 2Gb
 Current Speed: 2Gb
 Node WWN: 200000e08b074cb5
NPIV Port List:
 Virtual Port 1:
 Port WWN: 200000e08b074cb1
 Node WWN: 200000e08b074cb3
HBA Port WWN: 210100e08b274cb5
 Port Mode: Initiator
 OS Device Name: /dev/cfg/c2
 Manufacturer: QLogic Corp.
 Model: 375-3108-xx
 Firmware Version: 3.3.116
 FCode/BIOS Version: 1.13.08
 Serial Number: not available
 Driver Name: qlc
 Driver Version: 20070212-2.19
 Type: N-port
 State: online
 Supported Speeds: 1Gb 2Gb
 Current Speed: 2Gb
 Node WWN: 200100e08b274cb5
HBA Port WWN: 210000e08b072ab5
 Port Mode: Initiator
 OS Device Name: /dev/cfg/c3
 Manufacturer: QLogic Corp.
 Firmware Version: 3.3.116
 FCode/BIOS Version: 1.13.08
 Model: 375-3108-xx
 Serial Number: not available
 Driver Name: qlc
 Driver Version: 20070212-2.19
 Type: L-port
 State: online
 Supported Speeds: 1Gb 2Gb
 Current Speed: 2Gb
 Node WWN: 200000e08b072ab5
HBA Port WWN: 210100e08b272ab5
 Port Mode: Initiator
 OS Device Name: /dev/cfg/c4
 Manufacturer: QLogic Corp.
 Model: 375-3108-xx
 Firmware Version: 3.3.116
 FCode/BIOS Version: 1.13.08
 Serial Number: 0402F00-0549112808
 Driver Name: qlc
 Driver Version: 20070212-2.19
 Type: N-port
 State: online
 Supported Speeds: 1Gb 2Gb
 Current Speed: 2Gb
 Node WWN: 200100e08b272ab5

Example 2 Listing Target Mode HBA Ports

The following command lists all target mode fibre channel HBA ports on the host:

# fcinfo hba-port -t
 HBA Port WWN: 210100e08bb09221
 Port Mode: Target
 Port ID: 10700
 OS Device Name: Not Applicable
 Manufacturer: QLogic Corp.
 Model: d30ac7e0
 Firmware Version: 4.0.109
 FCode/BIOS Version: N/A
 Type: F-port
 State: online
 Supported Speeds: not established
 Current Speed: 2Gb
 Node WWN: 200100e08bb09221
 HBA Port WWN: 210000e08b909221
 Port Mode: Target
 Port ID: 10900
 OS Device Name: Not Applicable
 Manufacturer: QLogic Corp.
 Model: d37ad1e0
 Firmware Version: 4.0.109
 FCode/BIOS Version: N/A
 Type: F-port
 State: online
 Supported Speeds: not established
 Current Speed: 2Gb
 Node WWN: 200000e08b909221
 HBA Port WWN: 200000144fc2d508
 Port Mode: Target
 Port ID: 9a0025
 OS Device Name: Not Applicable
 Manufacturer: Sun Microsystems, Inc.
 Model: FCoE Virtual FC HBA
 Firmware Version: N/A
 FCode/BIOS Version: N/A
 Serial Number: N/A
 Driver Name: COMSTAR FCOET
 Driver Version: 1.0
 Type: F-port
 State: online
 Supported Speeds: 1Gb 10Gb
 Current Speed: 10Gb
 Node WWN: 100000144fc2d508
 HBA Port WWN: 200000144fc2d509
 Port Mode: Target
 Port ID: 9a0023
 OS Device Name: Not Applicable
 Manufacturer: Sun Microsystems, Inc.
 Model: FCoE Virtual FC HBA
 Firmware Version: N/A
 FCode/BIOS Version: N/A
 Serial Number: N/A
 Driver Name: COMSTAR FCOET
 Driver Version: 1.0
 Type: F-port
 State: online
 Supported Speeds: 1Gb 10Gb
 Current Speed: 10Gb
 Node WWN: 100000144fc2d509

Example 3 Listing HBA Ports and Link Statistics

The following command lists information for the HBA ports and the link statistics for those ports:

# fcinfo hba-port -l 210000e08b074cb5 210100e08b274cb5

HBA Port WWN: 210000e08b074cb5
 Port Mode: Initiator
 OS Device Name: /dev/cfg/c1
 Manufacturer: QLogic Corp.
 Model: 375-3108-xx
 Firmware Version: 3.3.116
 FCode/BIOS Version: 1.13.08
 Serial Number: 0402F00-0549112808
 Driver Name: qlc
 Driver Version: 20070212-2.19
 Type: N-port
 State: online
 Supported Speeds: 1Gb 2Gb
 Current Speed: 2Gb
 Node WWN: 200000e08b074cb5
 Link Error Statistics:
 Link Failure Count: 0
 Loss of Sync Count: 0
 Loss of Signal Count: 0
 Primitive Seq Protocol Error Count: 0
 Invalid Tx Word Count: 0
 Invalid CRC Count: 0
HBA Port WWN: 210100e08b274cb5
 Port Mode: Initiator
 OS Device Name: /dev/cfg/c2
 Manufacturer: QLogic Corp.
 Model: 375-3108-xx
 Firmware Version: 3.3.116
 FCode/BIOS Version: 1.13.08
 Serial Number: 0402F00-0549112808
 Driver Name: qlc
 Driver Version: 20070212-2.19
 Type: N-port
 State: online
 Supported Speeds: 1Gb 2Gb
 Current Speed: 2Gb
 Node WWN: 200100e08b274cb5
 Link Error Statistics:
 Link Failure Count: 0
 Loss of Sync Count: 0
 Loss of Signal Count: 0
 Primitive Seq Protocol Error Count: 0
 Invalid Tx Word Count: 0
 Invalid CRC Count: 0

Example 4 Listing All Remote Ports

The following command lists all remote ports that are visible through the given HBA port:

# fcinfo remote-port -p 210100e08b274cb5

Remote Port WWN: 50020f230000b4af
 Active FC4 Types: SCSI
 SCSI Target: yes
 Port Symbolic Name: unknown
 Node WWN: 50020f200000b4af
Remote Port WWN: 210000e08b07daa6
 Active FC4 Types: SCSI
 SCSI Target: no
 Port Symbolic Name: unknown
 Node WWN: 200000e08b07daa6
Remote Port WWN: 20030003ba27c788
 Active FC4 Types: SCSI
 SCSI Target: yes
 Port Symbolic Name: unknown
 Node WWN: 10000003ba27c788
Remote Port WWN: 210000e08b096a60
 Active FC4 Types: SCSI,IP
 SCSI Target: no
 Port Symbolic Name: unknown
 Node WWN: 200000e08b096a60

Example 5 Listing Remote Ports and Link Statistics

The following command lists information for the remote ports and the link statistics for those ports:

# fcinfo remote-port -l -p 210100e08b272ab5

Remote Port WWN: 210100e08b296a60
 Active FC4 Types: SCSI,IP
 SCSI Target: no
 Port Symbolic Name: unknown
 Node WWN: 200100e08b296a60
 Link Error Statistics:
 Link Failure Count: 0
 Loss of Sync Count: 0
 Loss of Signal Count: 0
 Primitive Seq Protocol Error Count: 0
 Invalid Tx Word Count: 0
 Invalid CRC Count: 0
Remote Port WWN: 20030003ba27d56d
 Active FC4 Types: SCSI
 SCSI Target: yes
 Port Symbolic Name: unknown
 Node WWN: 10000003ba27d56d
 Link Error Statistics:
 Link Failure Count: 0
 Loss of Sync Count: 4765165
 Loss of Signal Count: 4765165
 Primitive Seq Protocol Error Count: 0
 Invalid Tx Word Count: 0
 Invalid CRC Count: 0
Remote Port WWN: 210100e08b27f7a6
 Active FC4 Types: SCSI
 SCSI Target: no
 Port Symbolic Name: unknown
 Node WWN: 200100e08b27f7a6
 Link Error Statistics:
 Link Failure Count: 0
 Loss of Sync Count: 0
 Loss of Signal Count: 0
 Primitive Seq Protocol Error Count: 0
 Invalid Tx Word Count: 0
 Invalid CRC Count: 0
Remote Port WWN: 50020f230000b897
 Active FC4 Types: SCSI
 SCSI Target: yes
 Port Symbolic Name: unknown
 Node WWN: 50020f200000b897
 Link Error Statistics:
 Link Failure Count: 0
 Loss of Sync Count: 7
 Loss of Signal Count: 7
 Primitive Seq Protocol Error Count: 0
 Invalid Tx Word Count: 0
 Invalid CRC Count: 0
Remote Port WWN: 210100e08b27daa6
 Active FC4 Types: SCSI
 SCSI Target: no
 Port Symbolic Name: unknown
 Node WWN: 200100e08b27daa6
 Link Error Statistics:
 Link Failure Count: 0
 Loss of Sync Count: 0
 Loss of Signal Count: 0
 Primitive Seq Protocol Error Count: 0
 Invalid Tx Word Count: 0
 Invalid CRC Count: 0
Remote Port WWN: 210000e08b074cb5
 Active FC4 Types: SCSI,IP
 SCSI Target: no
 Port Symbolic Name: unknown
 Node WWN: 200000e08b074cb5
 Link Error Statistics:
 Link Failure Count: 0
 Loss of Sync Count: 0
 Loss of Signal Count: 0
 Primitive Seq Protocol Error Count: 0
 Invalid Tx Word Count: 0
 Invalid CRC Count: 0
Remote Port WWN: 210100e08b296060
 Active FC4 Types: SCSI
 SCSI Target: no
 Port Symbolic Name: unknown
 Node WWN: 200100e08b296060
 Link Error Statistics:
 Link Failure Count: 0
 Loss of Sync Count: 0
 Loss of Signal Count: 0
 Primitive Seq Protocol Error Count: 0
 Invalid Tx Word Count: 0
 Invalid CRC Count: 0

Example 6 Listing All SCSI Targets and Link Statistics

The following command lists all remote ports as well as the link statistics and scsi-target information:

# fcinfo remote-port -sl -p 210100e08b272ab5

Remote Port WWN: 210100e08b296a60
 Active FC4 Types: SCSI,IP
 SCSI Target: no
 Port Symbolic Name: unknown
 Node WWN: 200100e08b296a60
 Link Error Statistics:
 Link Failure Count: 0
 Loss of Sync Count: 0
 Loss of Signal Count: 0
 Primitive Seq Protocol Error Count: 0
 Invalid Tx Word Count: 0
 Invalid CRC Count: 0
Remote Port WWN: 20030003ba27d56d
 Active FC4 Types: SCSI
 SCSI Target: yes
 Port Symbolic Name: unknown
 Node WWN: 10000003ba27d56d
 Link Error Statistics:
 Link Failure Count: 0
 Loss of Sync Count: 4765165
 Loss of Signal Count: 4765165
 Primitive Seq Protocol Error Count: 0
 Invalid Tx Word Count: 0
 Invalid CRC Count: 0
 LUN: 0
 Vendor: SUN
 Product: T4
 OS Device Name: /dev/rdsk/c4t20030003BA27D56Dd0s2
 LUN: 1
 Vendor: SUN
 Product: T4
 OS Device Name: /dev/rdsk/c4t20030003BA27D56Dd1s2
Remote Port WWN: 210100e08b27f7a6
 Active FC4 Types: SCSI
 SCSI Target: no
 Port Symbolic Name: unknown
 Node WWN: 200100e08b27f7a6
 Link Error Statistics:
 Link Failure Count: 0
 Loss of Sync Count: 0
 Loss of Signal Count: 0
 Primitive Seq Protocol Error Count: 0
 Invalid Tx Word Count: 0
 Invalid CRC Count: 0
Remote Port WWN: 50020f230000b897
 Active FC4 Types: SCSI
 SCSI Target: yes
 Port Symbolic Name: unknown
 Node WWN: 50020f200000b897
 Link Error Statistics:
 Link Failure Count: 0
 Loss of Sync Count: 7
 Loss of Signal Count: 7
 Primitive Seq Protocol Error Count: 0
 Invalid Tx Word Count: 0
 Invalid CRC Count: 0
 LUN: 0
 Vendor: SUN
 Product: T300
 OS Device Name: Unknown
 LUN: 1
 Vendor: SUN
 Product: T300
 OS Device Name: /dev/rdsk/c4t50020F230000B897d1s2
 LUN: 2
 Vendor: SUN
 Product: T300
 OS Device Name: /dev/rdsk/c4t50020F230000B897d2s2
 LUN: 3
 Vendor: SUN
 Product: T300
 OS Device Name: /dev/rdsk/c4t50020F230000B897d3s2
 LUN: 4
 Vendor: SUN
 Product: T300
 OS Device Name: /dev/rdsk/c4t50020F230000B897d4s2
 LUN: 5
 Vendor: SUN
 Product: T300
 OS Device Name: /dev/rdsk/c4t50020F230000B897d5s2
 LUN: 6
 Vendor: SUN
 Product: T300
 OS Device Name: /dev/rdsk/c4t50020F230000B897d6s2
 LUN: 7
 Vendor: SUN
 Product: T300
 OS Device Name: /dev/rdsk/c4t50020F230000B897d7s2
 LUN: 8
 Vendor: SUN
 Product: T300
 OS Device Name: /dev/rdsk/c4t50020F230000B897d8s2
 LUN: 9
 Vendor: SUN
 Product: T300
 OS Device Name: /dev/rdsk/c4t50020F230000B897d9s2
 LUN: 10
 Vendor: SUN
 Product: T300
 OS Device Name: /dev/rdsk/c4t50020F230000B897d10s2
 LUN: 11
 Vendor: SUN
 Product: T300
 OS Device Name: /dev/rdsk/c4t50020F230000B897d11s2
 LUN: 12
 Vendor: SUN
 Product: T300
 OS Device Name: /dev/rdsk/c4t50020F230000B897d12s2
 LUN: 13
 Vendor: SUN
 Product: T300
 OS Device Name: /dev/rdsk/c4t50020F230000B897d13s2
 LUN: 14
 Vendor: SUN
 Product: T300
 OS Device Name: /dev/rdsk/c4t50020F230000B897d14s2
 LUN: 15
 Vendor: SUN
 Product: T300
 OS Device Name: /dev/rdsk/c4t50020F230000B897d15s2
Remote Port WWN: 210100e08b27daa6
 Active FC4 Types: SCSI
 SCSI Target: no
 Port Symbolic Name: unknown
 Node WWN: 200100e08b27daa6
 Link Error Statistics:
 Link Failure Count: 0
 Loss of Sync Count: 0
 Loss of Signal Count: 0
 Primitive Seq Protocol Error Count: 0
 Invalid Tx Word Count: 0
 Invalid CRC Count: 0
Remote Port WWN: 210000e08b074cb5
 Active FC4 Types: SCSI,IP
 SCSI Target: no
 Port Symbolic Name: unknown
 Node WWN: 200000e08b074cb5
 Link Error Statistics:
 Link Failure Count: 0
 Loss of Sync Count: 0
 Loss of Signal Count: 0
 Primitive Seq Protocol Error Count: 0
 Invalid Tx Word Count: 0
 Invalid CRC Count: 0
Remote Port WWN: 210100e08b296060
 Active FC4 Types: SCSI
 SCSI Target: no
 Port Symbolic Name: unknown
 Node WWN: 200100e08b296060
 Link Error Statistics:
 Link Failure Count: 0
 Loss of Sync Count: 0
 Loss of Signal Count: 0
 Primitive Seq Protocol Error Count: 0
 Invalid Tx Word Count: 0
 Invalid CRC Count: 0

Example 7 Listing SCSI Target Information

The following command lists all remote ports as well as the scsi-target information:

# fcinfo remote-port -s -p 210100e08b272ab5

Remote Port WWN: 210100e08b296a60
 Active FC4 Types: SCSI,IP
 SCSI Target: no
 Port Symbolic Name: unknown
 Node WWN: 200100e08b296060
Remote Port WWN: 20030003ba27d56d
 Active FC4 Types: SCSI
 SCSI Target: yes
 Port Symbolic Name: unknown
 Node WWN: 10000003ba27d56d
 LUN: 0
 Vendor: SUN
 Product: T4
 OS Device Name: /dev/rdsk/c4t20030003BA27D56Dd0s2
 LUN: 1
 Vendor: SUN
 Product: T4
 OS Device Name: /dev/rdsk/c4t20030003BA27D56Dd1s2
Remote Port WWN: 210100e08b27f7a6
 Active FC4 Types: SCSI
 SCSI Target: no
 Port Symbolic Name: unknown
 Node WWN: 200100e08b27f7a6
Remote Port WWN: 50020f230000b897
 Active FC4 Types: SCSI
 SCSI Target: yes
 Port Symbolic Name: unknown
 Node WWN: 50020f200000b897
 LUN: 0
 Vendor: SUN
 Product: T300
 OS Device Name: Unknown
 LUN: 1
 Vendor: SUN
 Product: T300
 OS Device Name: /dev/rdsk/c4t50020F230000B897d1s2
 LUN: 2
 Vendor: SUN
 Product: T300
 OS Device Name: /dev/rdsk/c4t50020F230000B897d2s2
 LUN: 3
 Vendor: SUN
 Product: T300
 OS Device Name: /dev/rdsk/c4t50020F230000B897d3s2
 LUN: 4
 Vendor: SUN
 Product: T300
 OS Device Name: /dev/rdsk/c4t50020F230000B897d4s2
 LUN: 5
 Vendor: SUN
 Product: T300
 OS Device Name: /dev/rdsk/c4t50020F230000B897d5s2
 LUN: 6
 Vendor: SUN
 Product: T300
 OS Device Name: /dev/rdsk/c4t50020F230000B897d6s2
 LUN: 7
 Vendor: SUN
 Product: T300
 OS Device Name: /dev/rdsk/c4t50020F230000B897d7s2
 LUN: 8
 Vendor: SUN
 Product: T300
 OS Device Name: /dev/rdsk/c4t50020F230000B897d8s2
 LUN: 9
 Vendor: SUN
 Product: T300
 OS Device Name: /dev/rdsk/c4t50020F230000B897d9s2
 LUN: 10
 Vendor: SUN
 Product: T300
 OS Device Name: /dev/rdsk/c4t50020F230000B897d10s2
 LUN: 11
 Vendor: SUN
 Product: T300
 OS Device Name: /dev/rdsk/c4t50020F230000B897d11s2
 LUN: 12
 Vendor: SUN
 Product: T300
 OS Device Name: /dev/rdsk/c4t50020F230000B897d12s2
 LUN: 13
 Vendor: SUN
 Product: T300
 OS Device Name: /dev/rdsk/c4t50020F230000B897d13s2
 LUN: 14
 Vendor: SUN
 Product: T300
 OS Device Name: /dev/rdsk/c4t50020F230000B897d14s2
 LUN: 15
 Vendor: SUN
 Product: T300
 OS Device Name: /dev/rdsk/c4t50020F230000B897d15s2
Remote Port WWN: 210100e08b27daa6
 Active FC4 Types: SCSI
 SCSI Target: no
 Port Symbolic Name: unknown
 Node WWN: 200100e08b27daa6
Remote Port WWN: 210000e08b074cb5
 Active FC4 Types: SCSI,IP
 SCSI Target: no
 Port Symbolic Name: unknown
 Node WWN: 200000e08b074cb5
Remote Port WWN: 210100e08b296060
 Active FC4 Types: SCSI
 SCSI Target: no
 Port Symbolic Name: unknown
 Node WWN: 200100e08b296060

Example 8 Listing the Logical Unit

The following command lists the logical unit:

# fcinfo logical-unit

/dev/rdsk/c0t600C0FF0000000000036223AE73EB705d0s2
/dev/rdsk/c0t600C0FF00000000000362272539E5B03d0s2
/dev/rmt/0n

Example 9 Displaying Additional Information for the Logical Unit

The following command displays additional information about the logical unit using the -v option for device /dev/rmt/On:

# fcinfo lu -v /dev/rmt/On

 OS Device Name: /dev/rmt/0n
 HBA Port WWN: 210000e07c030b91
 Remote Port WWN: 21010003b7830a6
 LUN: 0
 Vendor: STK
 Product: 9940A
 Device Type: Tape device

The following command displays additional information about the logical unit using the -v option for device /dev/rdsk/c0t600C0FF0000000000036223AE73EB705d0s2

# fcinfo logical-unit -v \e
 /dev/rdsk/c0t600C0FF0000000000036223AE73EB705d0s2

 OS Device Name: /dev/rdsk/c0t600C0FF0000000000036223AE73EB705d0s2
 HBA Port WWN: 210100e08b27a8a1
 Remote Port WWN: 256000c0ffc03622
 LUN: 0
 Remote Port WWN: 216000c0ff803622
 LUN: 0
 HBA Port WWN: 210000e08b07a8a1
 Remote Port WWN: 256000c0ffc03622
 LUN: 0
 Remote Port WWN: 216000c0ff803622
 LUN: 0
 Vendor: SUN
 Product: StorEdge 3510
 Device Type: Disk device

Example 10 Adding an NIPV Port

The following command adds an NPIV port to the HBA with a port name:

210000e08b170f1c

The NPIV port has a port name of 2000000000000001 and a node name of 2100000000000001.

# fcadm create-npiv-port -p 2000000000000001 -n 2100000000000001 \e
210000e08b170f1c

Created NPIV Port:
 HBA Port WWN: 2000000000000001
 Node WWN: 2100000000000001
 Physical HBA Port WWN: 210000e08b170f1c

Example 11 Adding an NIPV Port with Random WWN

The following command adds an NPIV port to the HBA with a randomly assigned port name of 210000e08b170f1c.

# fcadm create-npiv-port 210000e08b170f1c

Created NPIV Port:
 HBA Port WWN: 2038295824942801
 Node WWN: 2100392849248001
 Physical HBA Port WWN: 210000e08b170f1c

Example 12 Deleting an NIPV Port

The following command deletes an NPIV port.

# fcadm delete-npiv-port -p 2000000000000001 -w 2100000000000001 \e
210000e08b170f1c

Example 13 Creating an FCoE Target Port

The following command creates an FCoE port associated with the MAC interface nxge0.

# fcadm create-fcoe-port -t nxge0

Example 14 Deleting an FCoE Port

The following command deletes the FCoE port associated with the MAC interface nxge0.

# fcadm delete-fcoe-port -t nxge0

Example 15 Listing Information for an FCoE Port

The following command lists information for FCoE ports.

# fcadm list-fcoe-ports
HBA Port WWN: 200000144fc2d508
 Port Type: Target
 MAC Name: nxge0
 MTU Size: 9194
 MAC Factory Address: 00144fc2d508
 MAC Current Address: 00144fc2d508
HBA Port WWN: 200000144fc2d509
 Port Type: Target
 MAC Name: nxge1
 MTU Size: 9194
 MAC Factory Address: 00144fc2d509
 MAC Current Address: 00144fc2d509

Example 16 Reinitializing the Link of an FC Port

The following command forces the link connected with the port 200000144fc2d508 to reinitialize.

# fcadm force-lip 200000144fc2d508
ATTRIBUTES

See attributes(5) for descriptions of the following attributes:

ATTRIBUTE TYPE ATTRIBUTE VALUE
Interface Stability Committed
SEE ALSO

attributes(5)

ERROR MESSAGES

Errors that can occur in addition to the errors normally associated with system administration commands:

HBA_port_WWN: not found

Remote_port_WWN: not found

HBA_port_WWN: NPIV not supported on this HBA