xref: /titanic_51/usr/src/cmd/fm/dicts/SUNOS.po (revision ee5416c9d7e449233197d5d20bc6b81e4ff091b2)
1#
2# Copyright 2006 Sun Microsystems, Inc.  All rights reserved.
3# Use is subject to license terms.
4#
5# CDDL HEADER START
6#
7# The contents of this file are subject to the terms of the
8# Common Development and Distribution License (the "License").
9# You may not use this file except in compliance with the License.
10#
11# You can obtain a copy of the license at usr/src/OPENSOLARIS.LICENSE
12# or http://www.opensolaris.org/os/licensing.
13# See the License for the specific language governing permissions
14# and limitations under the License.
15#
16# When distributing Covered Code, include this CDDL HEADER in each
17# file and include the License file at usr/src/OPENSOLARIS.LICENSE.
18# If applicable, add the following below this CDDL HEADER, with the
19# fields enclosed by brackets "[]" replaced with your own identifying
20# information: Portions Copyright [yyyy] [name of copyright owner]
21#
22# CDDL HEADER END
23#
24#ident	"%Z%%M%	%I%	%E% SMI"
25#
26# DO NOT EDIT -- this file is generated by the Event Registry.
27#
28#
29# code: SUNOS-8000-0G
30# keys: ereport.sunos.unix.fm_panic
31#
32msgid "SUNOS-8000-0G.type"
33msgstr "Error"
34msgid "SUNOS-8000-0G.severity"
35msgstr "Major"
36msgid "SUNOS-8000-0G.description"
37msgstr "Errors have been detected that require a reboot to ensure system integrity.  Refer to %s for more information."
38msgid "SUNOS-8000-0G.response"
39msgstr "Solaris will attempt to save and diagnose the error telemetry"
40msgid "SUNOS-8000-0G.impact"
41msgstr "The system will sync files, save a crash dump if needed, and reboot"
42msgid "SUNOS-8000-0G.action"
43msgstr "Save the error summary below in case telemetry cannot be saved"
44#
45# code: SUNOS-8000-1L
46# keys: defect.sunos.eft.undiagnosable_problem
47#
48msgid "SUNOS-8000-1L.type"
49msgstr "Defect"
50msgid "SUNOS-8000-1L.severity"
51msgstr "Minor"
52msgid "SUNOS-8000-1L.description"
53msgstr "The EFT Diagnosis Engine encountered telemetry for which it is unable to produce a diagnosis.  Refer to %s for more information."
54msgid "SUNOS-8000-1L.response"
55msgstr "Error reports from the component will be logged for examination by Sun."
56msgid "SUNOS-8000-1L.impact"
57msgstr "Automated diagnosis and response for these events will not occur."
58msgid "SUNOS-8000-1L.action"
59msgstr "Run pkgchk -n SUNWfmd to ensure that fault management software is installed properly. Contact Sun for support."
60#
61# code: SUNOS-8000-20
62# keys: defect.Deprecated defect.io.pci.driver fault.io.pci.bus fault.io.pci.device
63#
64msgid "SUNOS-8000-20.type"
65msgstr "Fault"
66msgid "SUNOS-8000-20.severity"
67msgstr "Critical"
68msgid "SUNOS-8000-20.description"
69msgstr "A problem was detected in the SUNOS subsystem or controlling software.  Refer to %s for more information."
70msgid "SUNOS-8000-20.response"
71msgstr "One or more of device instances may be disabled"
72msgid "SUNOS-8000-20.impact"
73msgstr "Loss of services provided by the device instances associated with this fault"
74msgid "SUNOS-8000-20.action"
75msgstr "Ensure latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
76#
77# code: SUNOS-8000-3V
78# keys: defect.Deprecated fault.io.pci.bus fault.io.pci.device
79#
80msgid "SUNOS-8000-3V.type"
81msgstr "Fault"
82msgid "SUNOS-8000-3V.severity"
83msgstr "Critical"
84msgid "SUNOS-8000-3V.description"
85msgstr "A problem was detected in the PCI subsystem.  Refer to %s for more information."
86msgid "SUNOS-8000-3V.response"
87msgstr "One or more of device instances may be disabled"
88msgid "SUNOS-8000-3V.impact"
89msgstr "Loss of services provided by the device instances associated with this fault"
90msgid "SUNOS-8000-3V.action"
91msgstr "Schedule a repair procedure to replace the affected device. Use fmdump -v -u <EVENT_ID> to identify the device or contact Sun for support."
92#
93# code: SUNOS-8000-46
94# keys: defect.Deprecated defect.io.pci.driver fault.io.pci.device
95#
96msgid "SUNOS-8000-46.type"
97msgstr "Fault"
98msgid "SUNOS-8000-46.severity"
99msgstr "Critical"
100msgid "SUNOS-8000-46.description"
101msgstr "A problem was detected in the PCI subsystem or controlling software.  Refer to %s for more information."
102msgid "SUNOS-8000-46.response"
103msgstr "One or more of device instances may be disabled"
104msgid "SUNOS-8000-46.impact"
105msgstr "Loss of services provided by the device instances associated with this fault"
106msgid "SUNOS-8000-46.action"
107msgstr "Ensure latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
108#
109# code: SUNOS-8000-5T
110# keys: defect.Deprecated defect.io.pci.driver fault.io.pci.bus
111#
112msgid "SUNOS-8000-5T.type"
113msgstr "Fault"
114msgid "SUNOS-8000-5T.severity"
115msgstr "Critical"
116msgid "SUNOS-8000-5T.description"
117msgstr "A problem was detected in the PCI subsystem or controlling software.  Refer to %s for more information."
118msgid "SUNOS-8000-5T.response"
119msgstr "One or more of device instances may be disabled"
120msgid "SUNOS-8000-5T.impact"
121msgstr "Loss of services provided by the device instances associated with this fault"
122msgid "SUNOS-8000-5T.action"
123msgstr "Ensure latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
124#
125# code: SUNOS-8000-69
126# keys: defect.Deprecated fault.io.pci.device
127#
128msgid "SUNOS-8000-69.type"
129msgstr "Fault"
130msgid "SUNOS-8000-69.severity"
131msgstr "Critical"
132msgid "SUNOS-8000-69.description"
133msgstr "A problem was detected for a PCI controller  Refer to %s for more information."
134msgid "SUNOS-8000-69.response"
135msgstr "One or more of device instances may be disabled"
136msgid "SUNOS-8000-69.impact"
137msgstr "Loss of services provided by the device instances associated with this fault."
138msgid "SUNOS-8000-69.action"
139msgstr "Schedule a repair procedure to replace the affected device. Use fmdump -v -u <EVENT_ID> to identify the device or contact Sun for support."
140#
141# code: SUNOS-8000-7N
142# keys: defect.Deprecated fault.io.pci.bus
143#
144msgid "SUNOS-8000-7N.type"
145msgstr "Fault"
146msgid "SUNOS-8000-7N.severity"
147msgstr "Critical"
148msgid "SUNOS-8000-7N.description"
149msgstr "A problem was detected for a PCI bus  Refer to %s for more information."
150msgid "SUNOS-8000-7N.response"
151msgstr "One or more of device instances may be disabled"
152msgid "SUNOS-8000-7N.impact"
153msgstr "Loss of services provided by the device instances associated with this fault."
154msgid "SUNOS-8000-7N.action"
155msgstr "Schedule a repair procedure to replace the affected device. Use fmdump -v -u <EVENT_ID> to identify the device or contact Sun for support."
156#
157# code: SUNOS-8000-8W
158# keys: defect.Deprecated defect.io.pci.driver
159#
160msgid "SUNOS-8000-8W.type"
161msgstr "Fault"
162msgid "SUNOS-8000-8W.severity"
163msgstr "Critical"
164msgid "SUNOS-8000-8W.description"
165msgstr "A problem was detected in the PCI controller software  Refer to %s for more information."
166msgid "SUNOS-8000-8W.response"
167msgstr "One or more of device instances may be disabled"
168msgid "SUNOS-8000-8W.impact"
169msgstr "Loss of services provided by the device instances associated with this fault."
170msgid "SUNOS-8000-8W.action"
171msgstr "Ensure latest drivers and patches are installed. Use fmdump -v -u <EVENT_ID> to identify the module/package, or contact Sun for support."
172#
173# code: SUNOS-8000-91
174# keys: defect.sunos.zones.upgrade
175#
176msgid "SUNOS-8000-91.type"
177msgstr "Defect"
178msgid "SUNOS-8000-91.severity"
179msgstr "Minor"
180msgid "SUNOS-8000-91.description"
181msgstr "\n	The Solaris system or boot environment that is being upgraded\n	has non-global zones installed.  The current version of Live\n	Upgrade cannot upgrade a boot environment that has non-global\n	zones installed.\n	  Refer to %s for more information."
182msgid "SUNOS-8000-91.response"
183msgstr "The upgrade procedure has been terminated."
184msgid "SUNOS-8000-91.impact"
185msgstr "The Solaris system or boot environment is not upgraded."
186msgid "SUNOS-8000-91.action"
187msgstr "\n	Evaluate each of the choices below and select the one that is\n	best for your needs.  Contact Sun for support.\n	"
188#
189# code: SUNOS-8000-AK
190# keys: ereport.sunos.boot.upgrade.menu_lst
191#
192msgid "SUNOS-8000-AK.type"
193msgstr "Error"
194msgid "SUNOS-8000-AK.severity"
195msgstr "Critical"
196msgid "SUNOS-8000-AK.description"
197msgstr "Solaris OS could not automatically adjust\n/boot/grub/menu.lst\nto the new boot architecture\n  Refer to %s for more information."
198msgid "SUNOS-8000-AK.response"
199msgstr "No automated response.\n"
200msgid "SUNOS-8000-AK.impact"
201msgstr "Future reboots could fail until this problem is corrected.\n"
202msgid "SUNOS-8000-AK.action"
203msgstr "Examine /boot/grub/menu.lst and revise as\ndescribed in Details.\n"
204#
205# code: SUNOS-8000-CF
206# keys: ereport.sunos.boot.upgrade.menu_lst_bfu
207#
208msgid "SUNOS-8000-CF.type"
209msgstr "Error"
210msgid "SUNOS-8000-CF.severity"
211msgstr "Critical"
212msgid "SUNOS-8000-CF.description"
213msgstr "Solaris OS could not automatically adjust\n/boot/grub/menu.lst\nto the new boot architecture\n  Refer to %s for more information."
214msgid "SUNOS-8000-CF.response"
215msgstr "No automated response.\n"
216msgid "SUNOS-8000-CF.impact"
217msgstr "Future reboots could fail until this problem is corrected.\n"
218msgid "SUNOS-8000-CF.action"
219msgstr "Examine /boot/grub/menu.lst and revise as\ndescribed in Details.\n"
220