17c478bd9Sstevel@tonic-gate# 2*f6e214c7SGavin Maltby# Copyright (c) 2010, Oracle and/or its affiliates. All rights reserved. 37c478bd9Sstevel@tonic-gate# 47c478bd9Sstevel@tonic-gate# CDDL HEADER START 57c478bd9Sstevel@tonic-gate# 67c478bd9Sstevel@tonic-gate# The contents of this file are subject to the terms of the 79dd0f810Scindi# Common Development and Distribution License (the "License"). 89dd0f810Scindi# You may not use this file except in compliance with the License. 97c478bd9Sstevel@tonic-gate# 107c478bd9Sstevel@tonic-gate# You can obtain a copy of the license at usr/src/OPENSOLARIS.LICENSE 117c478bd9Sstevel@tonic-gate# or http://www.opensolaris.org/os/licensing. 127c478bd9Sstevel@tonic-gate# See the License for the specific language governing permissions 137c478bd9Sstevel@tonic-gate# and limitations under the License. 147c478bd9Sstevel@tonic-gate# 157c478bd9Sstevel@tonic-gate# When distributing Covered Code, include this CDDL HEADER in each 167c478bd9Sstevel@tonic-gate# file and include the License file at usr/src/OPENSOLARIS.LICENSE. 177c478bd9Sstevel@tonic-gate# If applicable, add the following below this CDDL HEADER, with the 187c478bd9Sstevel@tonic-gate# fields enclosed by brackets "[]" replaced with your own identifying 197c478bd9Sstevel@tonic-gate# information: Portions Copyright [yyyy] [name of copyright owner] 207c478bd9Sstevel@tonic-gate# 217c478bd9Sstevel@tonic-gate# CDDL HEADER END 227c478bd9Sstevel@tonic-gate# 23*f6e214c7SGavin Maltby 249dd0f810Scindi# DO NOT EDIT -- this file is generated by the Event Registry. 259dd0f810Scindi# 269dd0f810Scindi# 277c478bd9Sstevel@tonic-gate# code: SUNOS-8000-0G 287c478bd9Sstevel@tonic-gate# keys: ereport.sunos.unix.fm_panic 297c478bd9Sstevel@tonic-gate# 307c478bd9Sstevel@tonic-gatemsgid "SUNOS-8000-0G.type" 317c478bd9Sstevel@tonic-gatemsgstr "Error" 327c478bd9Sstevel@tonic-gatemsgid "SUNOS-8000-0G.severity" 337c478bd9Sstevel@tonic-gatemsgstr "Major" 347c478bd9Sstevel@tonic-gatemsgid "SUNOS-8000-0G.description" 357c478bd9Sstevel@tonic-gatemsgstr "Errors have been detected that require a reboot to ensure system integrity. Refer to %s for more information." 367c478bd9Sstevel@tonic-gatemsgid "SUNOS-8000-0G.response" 377c478bd9Sstevel@tonic-gatemsgstr "Solaris will attempt to save and diagnose the error telemetry" 387c478bd9Sstevel@tonic-gatemsgid "SUNOS-8000-0G.impact" 397c478bd9Sstevel@tonic-gatemsgstr "The system will sync files, save a crash dump if needed, and reboot" 407c478bd9Sstevel@tonic-gatemsgid "SUNOS-8000-0G.action" 417c478bd9Sstevel@tonic-gatemsgstr "Save the error summary below in case telemetry cannot be saved" 427c478bd9Sstevel@tonic-gate# 437c478bd9Sstevel@tonic-gate# code: SUNOS-8000-1L 447c478bd9Sstevel@tonic-gate# keys: defect.sunos.eft.undiagnosable_problem 457c478bd9Sstevel@tonic-gate# 467c478bd9Sstevel@tonic-gatemsgid "SUNOS-8000-1L.type" 477c478bd9Sstevel@tonic-gatemsgstr "Defect" 487c478bd9Sstevel@tonic-gatemsgid "SUNOS-8000-1L.severity" 497c478bd9Sstevel@tonic-gatemsgstr "Minor" 507c478bd9Sstevel@tonic-gatemsgid "SUNOS-8000-1L.description" 519dd0f810Scindimsgstr "The EFT Diagnosis Engine encountered telemetry for which it is unable to produce a diagnosis. Refer to %s for more information." 527c478bd9Sstevel@tonic-gatemsgid "SUNOS-8000-1L.response" 537c478bd9Sstevel@tonic-gatemsgstr "Error reports from the component will be logged for examination by Sun." 547c478bd9Sstevel@tonic-gatemsgid "SUNOS-8000-1L.impact" 557c478bd9Sstevel@tonic-gatemsgstr "Automated diagnosis and response for these events will not occur." 567c478bd9Sstevel@tonic-gatemsgid "SUNOS-8000-1L.action" 577c478bd9Sstevel@tonic-gatemsgstr "Run pkgchk -n SUNWfmd to ensure that fault management software is installed properly. Contact Sun for support." 587c478bd9Sstevel@tonic-gate# 597c478bd9Sstevel@tonic-gate# code: SUNOS-8000-20 609dd0f810Scindi# keys: defect.Deprecated defect.io.pci.driver fault.io.pci.bus fault.io.pci.device 617c478bd9Sstevel@tonic-gate# 627c478bd9Sstevel@tonic-gatemsgid "SUNOS-8000-20.type" 637c478bd9Sstevel@tonic-gatemsgstr "Fault" 647c478bd9Sstevel@tonic-gatemsgid "SUNOS-8000-20.severity" 657c478bd9Sstevel@tonic-gatemsgstr "Critical" 667c478bd9Sstevel@tonic-gatemsgid "SUNOS-8000-20.description" 679dd0f810Scindimsgstr "A problem was detected in the SUNOS subsystem or controlling software. Refer to %s for more information." 687c478bd9Sstevel@tonic-gatemsgid "SUNOS-8000-20.response" 697c478bd9Sstevel@tonic-gatemsgstr "One or more of device instances may be disabled" 707c478bd9Sstevel@tonic-gatemsgid "SUNOS-8000-20.impact" 717c478bd9Sstevel@tonic-gatemsgstr "Loss of services provided by the device instances associated with this fault" 727c478bd9Sstevel@tonic-gatemsgid "SUNOS-8000-20.action" 737c478bd9Sstevel@tonic-gatemsgstr "Ensure latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support." 747c478bd9Sstevel@tonic-gate# 757c478bd9Sstevel@tonic-gate# code: SUNOS-8000-3V 769dd0f810Scindi# keys: defect.Deprecated fault.io.pci.bus fault.io.pci.device 777c478bd9Sstevel@tonic-gate# 787c478bd9Sstevel@tonic-gatemsgid "SUNOS-8000-3V.type" 797c478bd9Sstevel@tonic-gatemsgstr "Fault" 807c478bd9Sstevel@tonic-gatemsgid "SUNOS-8000-3V.severity" 817c478bd9Sstevel@tonic-gatemsgstr "Critical" 827c478bd9Sstevel@tonic-gatemsgid "SUNOS-8000-3V.description" 839dd0f810Scindimsgstr "A problem was detected in the PCI subsystem. Refer to %s for more information." 847c478bd9Sstevel@tonic-gatemsgid "SUNOS-8000-3V.response" 857c478bd9Sstevel@tonic-gatemsgstr "One or more of device instances may be disabled" 867c478bd9Sstevel@tonic-gatemsgid "SUNOS-8000-3V.impact" 877c478bd9Sstevel@tonic-gatemsgstr "Loss of services provided by the device instances associated with this fault" 887c478bd9Sstevel@tonic-gatemsgid "SUNOS-8000-3V.action" 897c478bd9Sstevel@tonic-gatemsgstr "Schedule a repair procedure to replace the affected device. Use fmdump -v -u <EVENT_ID> to identify the device or contact Sun for support." 907c478bd9Sstevel@tonic-gate# 917c478bd9Sstevel@tonic-gate# code: SUNOS-8000-46 929dd0f810Scindi# keys: defect.Deprecated defect.io.pci.driver fault.io.pci.device 937c478bd9Sstevel@tonic-gate# 947c478bd9Sstevel@tonic-gatemsgid "SUNOS-8000-46.type" 957c478bd9Sstevel@tonic-gatemsgstr "Fault" 967c478bd9Sstevel@tonic-gatemsgid "SUNOS-8000-46.severity" 977c478bd9Sstevel@tonic-gatemsgstr "Critical" 987c478bd9Sstevel@tonic-gatemsgid "SUNOS-8000-46.description" 999dd0f810Scindimsgstr "A problem was detected in the PCI subsystem or controlling software. Refer to %s for more information." 1007c478bd9Sstevel@tonic-gatemsgid "SUNOS-8000-46.response" 1017c478bd9Sstevel@tonic-gatemsgstr "One or more of device instances may be disabled" 1027c478bd9Sstevel@tonic-gatemsgid "SUNOS-8000-46.impact" 1037c478bd9Sstevel@tonic-gatemsgstr "Loss of services provided by the device instances associated with this fault" 1047c478bd9Sstevel@tonic-gatemsgid "SUNOS-8000-46.action" 1057c478bd9Sstevel@tonic-gatemsgstr "Ensure latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support." 1067c478bd9Sstevel@tonic-gate# 1077c478bd9Sstevel@tonic-gate# code: SUNOS-8000-5T 1089dd0f810Scindi# keys: defect.Deprecated defect.io.pci.driver fault.io.pci.bus 1097c478bd9Sstevel@tonic-gate# 1107c478bd9Sstevel@tonic-gatemsgid "SUNOS-8000-5T.type" 1117c478bd9Sstevel@tonic-gatemsgstr "Fault" 1127c478bd9Sstevel@tonic-gatemsgid "SUNOS-8000-5T.severity" 1137c478bd9Sstevel@tonic-gatemsgstr "Critical" 1147c478bd9Sstevel@tonic-gatemsgid "SUNOS-8000-5T.description" 1159dd0f810Scindimsgstr "A problem was detected in the PCI subsystem or controlling software. Refer to %s for more information." 1167c478bd9Sstevel@tonic-gatemsgid "SUNOS-8000-5T.response" 1177c478bd9Sstevel@tonic-gatemsgstr "One or more of device instances may be disabled" 1187c478bd9Sstevel@tonic-gatemsgid "SUNOS-8000-5T.impact" 1197c478bd9Sstevel@tonic-gatemsgstr "Loss of services provided by the device instances associated with this fault" 1207c478bd9Sstevel@tonic-gatemsgid "SUNOS-8000-5T.action" 1217c478bd9Sstevel@tonic-gatemsgstr "Ensure latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support." 1227c478bd9Sstevel@tonic-gate# 1237c478bd9Sstevel@tonic-gate# code: SUNOS-8000-69 1249dd0f810Scindi# keys: defect.Deprecated fault.io.pci.device 1257c478bd9Sstevel@tonic-gate# 1267c478bd9Sstevel@tonic-gatemsgid "SUNOS-8000-69.type" 1277c478bd9Sstevel@tonic-gatemsgstr "Fault" 1287c478bd9Sstevel@tonic-gatemsgid "SUNOS-8000-69.severity" 1297c478bd9Sstevel@tonic-gatemsgstr "Critical" 1307c478bd9Sstevel@tonic-gatemsgid "SUNOS-8000-69.description" 1319dd0f810Scindimsgstr "A problem was detected for a PCI controller Refer to %s for more information." 1327c478bd9Sstevel@tonic-gatemsgid "SUNOS-8000-69.response" 1337c478bd9Sstevel@tonic-gatemsgstr "One or more of device instances may be disabled" 1347c478bd9Sstevel@tonic-gatemsgid "SUNOS-8000-69.impact" 1359dd0f810Scindimsgstr "Loss of services provided by the device instances associated with this fault." 1367c478bd9Sstevel@tonic-gatemsgid "SUNOS-8000-69.action" 1377c478bd9Sstevel@tonic-gatemsgstr "Schedule a repair procedure to replace the affected device. Use fmdump -v -u <EVENT_ID> to identify the device or contact Sun for support." 1387c478bd9Sstevel@tonic-gate# 1397c478bd9Sstevel@tonic-gate# code: SUNOS-8000-7N 1409dd0f810Scindi# keys: defect.Deprecated fault.io.pci.bus 1417c478bd9Sstevel@tonic-gate# 1427c478bd9Sstevel@tonic-gatemsgid "SUNOS-8000-7N.type" 1437c478bd9Sstevel@tonic-gatemsgstr "Fault" 1447c478bd9Sstevel@tonic-gatemsgid "SUNOS-8000-7N.severity" 1457c478bd9Sstevel@tonic-gatemsgstr "Critical" 1467c478bd9Sstevel@tonic-gatemsgid "SUNOS-8000-7N.description" 1479dd0f810Scindimsgstr "A problem was detected for a PCI bus Refer to %s for more information." 1487c478bd9Sstevel@tonic-gatemsgid "SUNOS-8000-7N.response" 1497c478bd9Sstevel@tonic-gatemsgstr "One or more of device instances may be disabled" 1507c478bd9Sstevel@tonic-gatemsgid "SUNOS-8000-7N.impact" 1519dd0f810Scindimsgstr "Loss of services provided by the device instances associated with this fault." 1527c478bd9Sstevel@tonic-gatemsgid "SUNOS-8000-7N.action" 1537c478bd9Sstevel@tonic-gatemsgstr "Schedule a repair procedure to replace the affected device. Use fmdump -v -u <EVENT_ID> to identify the device or contact Sun for support." 1547c478bd9Sstevel@tonic-gate# 1557c478bd9Sstevel@tonic-gate# code: SUNOS-8000-8W 1569dd0f810Scindi# keys: defect.Deprecated defect.io.pci.driver 1577c478bd9Sstevel@tonic-gate# 1587c478bd9Sstevel@tonic-gatemsgid "SUNOS-8000-8W.type" 1597c478bd9Sstevel@tonic-gatemsgstr "Fault" 1607c478bd9Sstevel@tonic-gatemsgid "SUNOS-8000-8W.severity" 1617c478bd9Sstevel@tonic-gatemsgstr "Critical" 1627c478bd9Sstevel@tonic-gatemsgid "SUNOS-8000-8W.description" 1639dd0f810Scindimsgstr "A problem was detected in the PCI controller software Refer to %s for more information." 1647c478bd9Sstevel@tonic-gatemsgid "SUNOS-8000-8W.response" 1657c478bd9Sstevel@tonic-gatemsgstr "One or more of device instances may be disabled" 1667c478bd9Sstevel@tonic-gatemsgid "SUNOS-8000-8W.impact" 1679dd0f810Scindimsgstr "Loss of services provided by the device instances associated with this fault." 1687c478bd9Sstevel@tonic-gatemsgid "SUNOS-8000-8W.action" 1697c478bd9Sstevel@tonic-gatemsgstr "Ensure latest drivers and patches are installed. Use fmdump -v -u <EVENT_ID> to identify the module/package, or contact Sun for support." 1709dd0f810Scindi# 1719dd0f810Scindi# code: SUNOS-8000-91 1729dd0f810Scindi# keys: defect.sunos.zones.upgrade 1739dd0f810Scindi# 1749dd0f810Scindimsgid "SUNOS-8000-91.type" 1759dd0f810Scindimsgstr "Defect" 1769dd0f810Scindimsgid "SUNOS-8000-91.severity" 1779dd0f810Scindimsgstr "Minor" 1789dd0f810Scindimsgid "SUNOS-8000-91.description" 1799dd0f810Scindimsgstr "\n The Solaris system or boot environment that is being upgraded\n has non-global zones installed. The current version of Live\n Upgrade cannot upgrade a boot environment that has non-global\n zones installed.\n Refer to %s for more information." 1809dd0f810Scindimsgid "SUNOS-8000-91.response" 1819dd0f810Scindimsgstr "The upgrade procedure has been terminated." 1829dd0f810Scindimsgid "SUNOS-8000-91.impact" 1839dd0f810Scindimsgstr "The Solaris system or boot environment is not upgraded." 1849dd0f810Scindimsgid "SUNOS-8000-91.action" 1859dd0f810Scindimsgstr "\n Evaluate each of the choices below and select the one that is\n best for your needs. Contact Sun for support.\n " 1869dd0f810Scindi# 1879dd0f810Scindi# code: SUNOS-8000-AK 1889dd0f810Scindi# keys: ereport.sunos.boot.upgrade.menu_lst 1899dd0f810Scindi# 1909dd0f810Scindimsgid "SUNOS-8000-AK.type" 1919dd0f810Scindimsgstr "Error" 1929dd0f810Scindimsgid "SUNOS-8000-AK.severity" 1939dd0f810Scindimsgstr "Critical" 1949dd0f810Scindimsgid "SUNOS-8000-AK.description" 1959dd0f810Scindimsgstr "Solaris OS could not automatically adjust\n/boot/grub/menu.lst\nto the new boot architecture\n Refer to %s for more information." 1969dd0f810Scindimsgid "SUNOS-8000-AK.response" 197*f6e214c7SGavin Maltbymsgstr "No automated response." 1989dd0f810Scindimsgid "SUNOS-8000-AK.impact" 199*f6e214c7SGavin Maltbymsgstr "Future reboots could fail until this problem is corrected." 2009dd0f810Scindimsgid "SUNOS-8000-AK.action" 201*f6e214c7SGavin Maltbymsgstr "Examine /boot/grub/menu.lst and revise as\ndescribed in Details." 2029dd0f810Scindi# 2039dd0f810Scindi# code: SUNOS-8000-CF 2049dd0f810Scindi# keys: ereport.sunos.boot.upgrade.menu_lst_bfu 2059dd0f810Scindi# 2069dd0f810Scindimsgid "SUNOS-8000-CF.type" 2079dd0f810Scindimsgstr "Error" 2089dd0f810Scindimsgid "SUNOS-8000-CF.severity" 2099dd0f810Scindimsgstr "Critical" 2109dd0f810Scindimsgid "SUNOS-8000-CF.description" 2119dd0f810Scindimsgstr "Solaris OS could not automatically adjust\n/boot/grub/menu.lst\nto the new boot architecture\n Refer to %s for more information." 2129dd0f810Scindimsgid "SUNOS-8000-CF.response" 213*f6e214c7SGavin Maltbymsgstr "No automated response." 2149dd0f810Scindimsgid "SUNOS-8000-CF.impact" 215*f6e214c7SGavin Maltbymsgstr "Future reboots could fail until this problem is corrected." 2169dd0f810Scindimsgid "SUNOS-8000-CF.action" 217*f6e214c7SGavin Maltbymsgstr "Examine /boot/grub/menu.lst and revise as\ndescribed in Details." 21832d4e834STarik Soydan# 21995efa359SEric Schrock# code: SUNOS-8000-DM 22095efa359SEric Schrock# keys: defect.sunos.smf.svc.maintenance 22195efa359SEric Schrock# 22295efa359SEric Schrockmsgid "SUNOS-8000-DM.type" 22395efa359SEric Schrockmsgstr "Defect" 22495efa359SEric Schrockmsgid "SUNOS-8000-DM.severity" 22595efa359SEric Schrockmsgstr "Major" 22695efa359SEric Schrockmsgid "SUNOS-8000-DM.description" 22795efa359SEric Schrockmsgstr "A service failed and could not be restarted. Refer to %s for more information." 22895efa359SEric Schrockmsgid "SUNOS-8000-DM.response" 22995efa359SEric Schrockmsgstr "The service has been placed into the maintenance state." 23095efa359SEric Schrockmsgid "SUNOS-8000-DM.impact" 23195efa359SEric Schrockmsgstr "The service is unavailable." 23295efa359SEric Schrockmsgid "SUNOS-8000-DM.action" 233705e9f42SStephen Hansonmsgstr "Run 'svcs -x' to determine why the service failed and the location of logfiles, if any." 23495efa359SEric Schrock# 23532d4e834STarik Soydan# code: SUNOS-8000-E8 236bbc3b4a5STarik Soydan# keys: defect.sunos.eft.undiag.checkpoint 23732d4e834STarik Soydan# 23832d4e834STarik Soydanmsgid "SUNOS-8000-E8.type" 23932d4e834STarik Soydanmsgstr "Defect" 24032d4e834STarik Soydanmsgid "SUNOS-8000-E8.severity" 241bbc3b4a5STarik Soydanmsgstr "Minor" 24232d4e834STarik Soydanmsgid "SUNOS-8000-E8.description" 2439cdb3868STarik Soydanmsgstr "The diagnosis engine encountered an error while resuming diagnosis. Refer to %s for more information." 24432d4e834STarik Soydanmsgid "SUNOS-8000-E8.response" 2459cdb3868STarik Soydanmsgstr "Error reports have been logged for examination by Sun." 24632d4e834STarik Soydanmsgid "SUNOS-8000-E8.impact" 2479cdb3868STarik Soydanmsgstr "Automated diagnosis and response for these events will not occur." 24832d4e834STarik Soydanmsgid "SUNOS-8000-E8.action" 2499cdb3868STarik Soydanmsgstr "Remove the diagnosis engine checkpoint file '/var/fm/fmd/ckpt/eft/eft', repair this defect, and restart the fault manager." 25032d4e834STarik Soydan# 25132d4e834STarik Soydan# code: SUNOS-8000-FU 252bbc3b4a5STarik Soydan# keys: defect.sunos.eft.undiag.fme 25332d4e834STarik Soydan# 25432d4e834STarik Soydanmsgid "SUNOS-8000-FU.type" 25532d4e834STarik Soydanmsgstr "Defect" 25632d4e834STarik Soydanmsgid "SUNOS-8000-FU.severity" 257bbc3b4a5STarik Soydanmsgstr "Major" 25832d4e834STarik Soydanmsgid "SUNOS-8000-FU.description" 2599cdb3868STarik Soydanmsgstr "The diagnosis engine encountered telemetry for which it was unable to perform a diagnosis. Refer to %s for more information." 26032d4e834STarik Soydanmsgid "SUNOS-8000-FU.response" 2619cdb3868STarik Soydanmsgstr "Error reports have been logged for examination by Sun." 26232d4e834STarik Soydanmsgid "SUNOS-8000-FU.impact" 2639cdb3868STarik Soydanmsgstr "Automated diagnosis and response for these events will not occur." 26432d4e834STarik Soydanmsgid "SUNOS-8000-FU.action" 2659cdb3868STarik Soydanmsgstr "Ensure that the latest Solaris Kernel and Predictive Self-Healing (PSH) patches are installed." 26632d4e834STarik Soydan# 26732d4e834STarik Soydan# code: SUNOS-8000-G7 268bbc3b4a5STarik Soydan# keys: defect.sunos.eft.undiag.limit 26932d4e834STarik Soydan# 27032d4e834STarik Soydanmsgid "SUNOS-8000-G7.type" 27132d4e834STarik Soydanmsgstr "Defect" 27232d4e834STarik Soydanmsgid "SUNOS-8000-G7.severity" 27332d4e834STarik Soydanmsgstr "Minor" 27432d4e834STarik Soydanmsgid "SUNOS-8000-G7.description" 2759cdb3868STarik Soydanmsgstr "The diagnosis engine hit a limit restriction and was unable to perform a diagnosis. Refer to %s for more information." 27632d4e834STarik Soydanmsgid "SUNOS-8000-G7.response" 2779cdb3868STarik Soydanmsgstr "Error reports have been logged for examination by Sun." 27832d4e834STarik Soydanmsgid "SUNOS-8000-G7.impact" 2799cdb3868STarik Soydanmsgstr "Automated diagnosis and response for these events will not occur." 28032d4e834STarik Soydanmsgid "SUNOS-8000-G7.action" 2819cdb3868STarik Soydanmsgstr "Check the diagnosis engine configuration file '/usr/lib/fm/fmd/plugins/eft.conf' and ensure that no limit restrictions are set, then repair this defect, and restart the fault manager." 282bbc3b4a5STarik Soydan# 283bbc3b4a5STarik Soydan# code: SUNOS-8000-HV 284bbc3b4a5STarik Soydan# keys: defect.sunos.eft.undiag.unknown 285bbc3b4a5STarik Soydan# 286bbc3b4a5STarik Soydanmsgid "SUNOS-8000-HV.type" 287bbc3b4a5STarik Soydanmsgstr "Defect" 288bbc3b4a5STarik Soydanmsgid "SUNOS-8000-HV.severity" 289bbc3b4a5STarik Soydanmsgstr "Minor" 290bbc3b4a5STarik Soydanmsgid "SUNOS-8000-HV.description" 2919cdb3868STarik Soydanmsgstr "The diagnosis engine encountered telemetry for which it was unable to perform a diagnosis. Refer to %s for more information." 292bbc3b4a5STarik Soydanmsgid "SUNOS-8000-HV.response" 2939cdb3868STarik Soydanmsgstr "Error reports have been logged for examination by Sun." 294bbc3b4a5STarik Soydanmsgid "SUNOS-8000-HV.impact" 2959cdb3868STarik Soydanmsgstr "Automated diagnosis and response for these events will not occur." 296bbc3b4a5STarik Soydanmsgid "SUNOS-8000-HV.action" 2979cdb3868STarik Soydanmsgstr "Ensure that the latest Solaris Kernel and Predictive Self-Healing (PSH) patches are installed." 298705e9f42SStephen Hanson# 299705e9f42SStephen Hanson# code: SUNOS-8000-J0 300705e9f42SStephen Hanson# keys: defect.sunos.eft.unexpected_telemetry fault.sunos.eft.unexpected_telemetry 301705e9f42SStephen Hanson# 302705e9f42SStephen Hansonmsgid "SUNOS-8000-J0.type" 303705e9f42SStephen Hansonmsgstr "Fault" 304705e9f42SStephen Hansonmsgid "SUNOS-8000-J0.severity" 305705e9f42SStephen Hansonmsgstr "Major" 306705e9f42SStephen Hansonmsgid "SUNOS-8000-J0.description" 307*f6e214c7SGavin Maltbymsgstr "The diagnosis engine encountered telemetry from the listed devices for which it was unable to perform a diagnosis - %.\n Refer to %s for more information. Refer to %s for more information." 308705e9f42SStephen Hansonmsgid "SUNOS-8000-J0.response" 309705e9f42SStephen Hansonmsgstr "Error reports have been logged for examination by Sun.\n" 310705e9f42SStephen Hansonmsgid "SUNOS-8000-J0.impact" 311705e9f42SStephen Hansonmsgstr "Automated diagnosis and response for these events will not occur.\n" 312705e9f42SStephen Hansonmsgid "SUNOS-8000-J0.action" 313705e9f42SStephen Hansonmsgstr "Ensure that the latest Solaris Kernel and Predictive Self-Healing (PSH) patches are installed.\n" 314*f6e214c7SGavin Maltby# 315*f6e214c7SGavin Maltby# code: SUNOS-8000-KL 316*f6e214c7SGavin Maltby# keys: defect.sunos.kernel.panic 317*f6e214c7SGavin Maltby# 318*f6e214c7SGavin Maltbymsgid "SUNOS-8000-KL.type" 319*f6e214c7SGavin Maltbymsgstr "Defect" 320*f6e214c7SGavin Maltbymsgid "SUNOS-8000-KL.severity" 321*f6e214c7SGavin Maltbymsgstr "Major" 322*f6e214c7SGavin Maltbymsgid "SUNOS-8000-KL.description" 323*f6e214c7SGavin Maltbymsgstr "The system has rebooted after a kernel panic. Refer to %s for more information." 324*f6e214c7SGavin Maltbymsgid "SUNOS-8000-KL.response" 325*f6e214c7SGavin Maltbymsgstr "The failed system image was dumped to the dump device. If savecore is enabled (see dumpadm(1M)) a copy of the dump will be written to the savecore directory %<fault-list[0].dump-dir>." 326*f6e214c7SGavin Maltbymsgid "SUNOS-8000-KL.impact" 327*f6e214c7SGavin Maltbymsgstr "There may be some performance impact while the panic is copied to the savecore directory. Disk space usage by panics can be substantial." 328*f6e214c7SGavin Maltbymsgid "SUNOS-8000-KL.action" 329*f6e214c7SGavin Maltbymsgstr "If savecore is not enabled then please take steps to preserve the crash image.\nUse 'fmdump -Vp -u %<uuid>' to view more panic detail. Please refer to the knowledge article for additional information." 330