xref: /titanic_51/usr/src/cmd/fm/dicts/SUN4V.po (revision f34a71784df3fbc5d1227a7b6201fd318ad1667e)
1#
2# Copyright 2009 Sun Microsystems, Inc.  All rights reserved.
3# Use is subject to license terms.
4#
5# CDDL HEADER START
6#
7# The contents of this file are subject to the terms of the
8# Common Development and Distribution License (the "License").
9# You may not use this file except in compliance with the License.
10#
11# You can obtain a copy of the license at usr/src/OPENSOLARIS.LICENSE
12# or http://www.opensolaris.org/os/licensing.
13# See the License for the specific language governing permissions
14# and limitations under the License.
15#
16# When distributing Covered Code, include this CDDL HEADER in each
17# file and include the License file at usr/src/OPENSOLARIS.LICENSE.
18# If applicable, add the following below this CDDL HEADER, with the
19# fields enclosed by brackets "[]" replaced with your own identifying
20# information: Portions Copyright [yyyy] [name of copyright owner]
21#
22# CDDL HEADER END
23#
24# DO NOT EDIT -- this file is generated by the Event Registry.
25#
26#
27# code: SUN4V-8000-1S
28# keys: fault.cpu.ultraSPARC-T1.ireg
29#
30msgid "SUN4V-8000-1S.type"
31msgstr "Fault"
32msgid "SUN4V-8000-1S.severity"
33msgstr "Minor"
34msgid "SUN4V-8000-1S.description"
35msgstr "The number of errors associated with this CPU has exceeded \n         acceptable levels.  Refer to %s for more information."
36msgid "SUN4V-8000-1S.response"
37msgstr "The fault manager will attempt to remove the affected CPU from service."
38msgid "SUN4V-8000-1S.impact"
39msgstr "System performance may be affected."
40msgid "SUN4V-8000-1S.action"
41msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>."
42#
43# code: SUN4V-8000-2A
44# keys: fault.cpu.ultraSPARC-T1.freg
45#
46msgid "SUN4V-8000-2A.type"
47msgstr "Fault"
48msgid "SUN4V-8000-2A.severity"
49msgstr "Major"
50msgid "SUN4V-8000-2A.description"
51msgstr "The number of errors associated with this CPU has exceeded \n         acceptable levels.  Refer to %s for more information."
52msgid "SUN4V-8000-2A.response"
53msgstr "None"
54msgid "SUN4V-8000-2A.impact"
55msgstr "System performance may be affected."
56msgid "SUN4V-8000-2A.action"
57msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>."
58#
59# code: SUN4V-8000-3P
60# keys: fault.cpu.ultraSPARC-T1.itlb
61#
62msgid "SUN4V-8000-3P.type"
63msgstr "Fault"
64msgid "SUN4V-8000-3P.severity"
65msgstr "Minor"
66msgid "SUN4V-8000-3P.description"
67msgstr "The number of errors associated with this CPU has exceeded \n         acceptable levels.  Refer to %s for more information."
68msgid "SUN4V-8000-3P.response"
69msgstr "The fault manager will attempt to remove the affected CPU from service."
70msgid "SUN4V-8000-3P.impact"
71msgstr "System performance may be affected.\n"
72msgid "SUN4V-8000-3P.action"
73msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>."
74#
75# code: SUN4V-8000-4D
76# keys: fault.cpu.ultraSPARC-T1.dtlb
77#
78msgid "SUN4V-8000-4D.type"
79msgstr "Fault"
80msgid "SUN4V-8000-4D.severity"
81msgstr "Minor"
82msgid "SUN4V-8000-4D.description"
83msgstr "The number of errors associated with this CPU has exceeded \n         acceptable levels.  Refer to %s for more information."
84msgid "SUN4V-8000-4D.response"
85msgstr "The fault manager will attempt to remove the affected CPU from service."
86msgid "SUN4V-8000-4D.impact"
87msgstr "System performance may be affected.\n"
88msgid "SUN4V-8000-4D.action"
89msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>."
90#
91# code: SUN4V-8000-5H
92# keys: fault.cpu.ultraSPARC-T1.icache
93#
94msgid "SUN4V-8000-5H.type"
95msgstr "Fault"
96msgid "SUN4V-8000-5H.severity"
97msgstr "Minor"
98msgid "SUN4V-8000-5H.description"
99msgstr "The number of errors associated with this CPU has exceeded \n         acceptable levels.  Refer to %s for more information."
100msgid "SUN4V-8000-5H.response"
101msgstr "The fault manager will attempt to remove the affected CPU from service."
102msgid "SUN4V-8000-5H.impact"
103msgstr "System performance may be affected.\n"
104msgid "SUN4V-8000-5H.action"
105msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>."
106#
107# code: SUN4V-8000-63
108# keys: fault.cpu.ultraSPARC-T1.dcache
109#
110msgid "SUN4V-8000-63.type"
111msgstr "Fault"
112msgid "SUN4V-8000-63.severity"
113msgstr "Minor"
114msgid "SUN4V-8000-63.description"
115msgstr "The number of errors associated with this CPU has exceeded \n         acceptable levels.  Refer to %s for more information."
116msgid "SUN4V-8000-63.response"
117msgstr "The fault manager will attempt to remove the affected CPU from service."
118msgid "SUN4V-8000-63.impact"
119msgstr "System performance may be affected.\n"
120msgid "SUN4V-8000-63.action"
121msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>."
122#
123# code: SUN4V-8000-7Y
124# keys: fault.cpu.ultraSPARC-T1.mau
125#
126msgid "SUN4V-8000-7Y.type"
127msgstr "Fault"
128msgid "SUN4V-8000-7Y.severity"
129msgstr "Major"
130msgid "SUN4V-8000-7Y.description"
131msgstr "The number of errors associated with this CPU has exceeded \n         acceptable levels.  Refer to %s for more information."
132msgid "SUN4V-8000-7Y.response"
133msgstr "None"
134msgid "SUN4V-8000-7Y.impact"
135msgstr "System performance may be affected.\n"
136msgid "SUN4V-8000-7Y.action"
137msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>."
138#
139# code: SUN4V-8000-8Q
140# keys: fault.cpu.ultraSPARC-T1.l2cachedata
141#
142msgid "SUN4V-8000-8Q.type"
143msgstr "Fault"
144msgid "SUN4V-8000-8Q.severity"
145msgstr "Critical"
146msgid "SUN4V-8000-8Q.description"
147msgstr "The number of errors associated with this CPU has exceeded \n         acceptable levels.  Refer to %s for more information."
148msgid "SUN4V-8000-8Q.response"
149msgstr "None"
150msgid "SUN4V-8000-8Q.impact"
151msgstr "System performance may be affected.\n"
152msgid "SUN4V-8000-8Q.action"
153msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>."
154#
155# code: SUN4V-8000-9C
156# keys: fault.cpu.ultraSPARC-T1.l2cachetag
157#
158msgid "SUN4V-8000-9C.type"
159msgstr "Fault"
160msgid "SUN4V-8000-9C.severity"
161msgstr "Critical"
162msgid "SUN4V-8000-9C.description"
163msgstr "The number of errors associated with this CPU has exceeded \n         acceptable levels.  Refer to %s for more information."
164msgid "SUN4V-8000-9C.response"
165msgstr "None"
166msgid "SUN4V-8000-9C.impact"
167msgstr "System performance may be affected.\n"
168msgid "SUN4V-8000-9C.action"
169msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>."
170#
171# code: SUN4V-8000-AR
172# keys: fault.cpu.ultraSPARC-T1.l2cachectl
173#
174msgid "SUN4V-8000-AR.type"
175msgstr "Fault"
176msgid "SUN4V-8000-AR.severity"
177msgstr "Critical"
178msgid "SUN4V-8000-AR.description"
179msgstr "The number of errors associated with this CPU has exceeded \n         acceptable levels.  Refer to %s for more information."
180msgid "SUN4V-8000-AR.response"
181msgstr "None"
182msgid "SUN4V-8000-AR.impact"
183msgstr "System performance may be affected.\n"
184msgid "SUN4V-8000-AR.action"
185msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>."
186#
187# code: SUN4V-8000-C4
188# keys: fault.memory.page
189#
190msgid "SUN4V-8000-C4.type"
191msgstr "Fault"
192msgid "SUN4V-8000-C4.severity"
193msgstr "Minor"
194msgid "SUN4V-8000-C4.description"
195msgstr "The number of errors associated with this memory module continues to exceed acceptable levels.  Refer to %s for more information."
196msgid "SUN4V-8000-C4.response"
197msgstr "An attempt will be made to remove this memory page from service."
198msgid "SUN4V-8000-C4.impact"
199msgstr "The performance of the system may be minimally impacted as a result of removing the memory page from operation."
200msgid "SUN4V-8000-C4.action"
201msgstr "No repair action is recommended at this time."
202#
203# code: SUN4V-8000-DX
204# keys: fault.memory.dimm
205#
206msgid "SUN4V-8000-DX.type"
207msgstr "Fault"
208msgid "SUN4V-8000-DX.severity"
209msgstr "Major"
210msgid "SUN4V-8000-DX.description"
211msgstr "The number of correctable errors associated with this memory module has exceeded acceptable levels.  Refer to %s for more information."
212msgid "SUN4V-8000-DX.response"
213msgstr "Pages of memory associated with this memory module have been removed from service, up to a limit which has now been reached."
214msgid "SUN4V-8000-DX.impact"
215msgstr "Total system memory capacity has been reduced."
216msgid "SUN4V-8000-DX.action"
217msgstr "Schedule a repair procedure to replace the affected memory module. Use 'fmadm faulty' to identify the memory module."
218#
219# code: SUN4V-8000-E2
220# keys: fault.memory.bank
221#
222msgid "SUN4V-8000-E2.type"
223msgstr "Fault"
224msgid "SUN4V-8000-E2.severity"
225msgstr "Critical"
226msgid "SUN4V-8000-E2.description"
227msgstr "The number of errors associated with this memory module has exceeded acceptable levels.  Refer to %s for more information."
228msgid "SUN4V-8000-E2.response"
229msgstr "Pages of memory associated with this memory module are being removed from service as errors are reported."
230msgid "SUN4V-8000-E2.impact"
231msgstr "Total system memory capacity will be reduced as pages are retired."
232msgid "SUN4V-8000-E2.action"
233msgstr "Schedule a repair procedure to replace the affected memory module. Use fmdump -v -u <EVENT_ID> to identify the module."
234#
235# code: SUN4V-8000-FJ
236# keys: fault.memory.link-c
237#
238msgid "SUN4V-8000-FJ.type"
239msgstr "Fault"
240msgid "SUN4V-8000-FJ.severity"
241msgstr "Major"
242msgid "SUN4V-8000-FJ.description"
243msgstr "A problem was detected in the interconnect between a memory DIMM module and\nits memory controller. \n  Refer to %s for more information."
244msgid "SUN4V-8000-FJ.response"
245msgstr "No automated response.\n"
246msgid "SUN4V-8000-FJ.impact"
247msgstr "System performance may be impacted.\n"
248msgid "SUN4V-8000-FJ.action"
249msgstr "At convenient time, try reseating the memory module(s).  If problem persists,\ncontact Sun to schedule part replacement.\n"
250#
251# code: SUN4V-8000-GE
252# keys: fault.cpu.ultraSPARC-T2.ireg
253#
254msgid "SUN4V-8000-GE.type"
255msgstr "Fault"
256msgid "SUN4V-8000-GE.severity"
257msgstr "Minor"
258msgid "SUN4V-8000-GE.description"
259msgstr "The number of integer register errors associated with this thread has exceeded acceptable levels.\n  Refer to %s for more information."
260msgid "SUN4V-8000-GE.response"
261msgstr "The fault manager will attempt to remove the affected thread\nfrom service.\n"
262msgid "SUN4V-8000-GE.impact"
263msgstr "System performance may be affected. \n"
264msgid "SUN4V-8000-GE.action"
265msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n"
266#
267# code: SUN4V-8000-HP
268# keys: fault.cpu.ultraSPARC-T2.freg
269#
270msgid "SUN4V-8000-HP.type"
271msgstr "Fault"
272msgid "SUN4V-8000-HP.severity"
273msgstr "Minor"
274msgid "SUN4V-8000-HP.description"
275msgstr "The number of floating register errors associated with this thread has exceeded acceptable levels.\n  Refer to %s for more information."
276msgid "SUN4V-8000-HP.response"
277msgstr "The fault manager will attempt to remove the affected thread\nfrom service.\n"
278msgid "SUN4V-8000-HP.impact"
279msgstr "System performance may be affected. \n"
280msgid "SUN4V-8000-HP.action"
281msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n"
282#
283# code: SUN4V-8000-JA
284# keys: fault.cpu.ultraSPARC-T2.misc_reg
285#
286msgid "SUN4V-8000-JA.type"
287msgstr "Fault"
288msgid "SUN4V-8000-JA.severity"
289msgstr "Minor"
290msgid "SUN4V-8000-JA.description"
291msgstr "The number of ancillary register errors associated with this thread has exceeded acceptable levels.\n  Refer to %s for more information."
292msgid "SUN4V-8000-JA.response"
293msgstr "The fault manager will attempt to remove the affected thread\nfrom service.\n"
294msgid "SUN4V-8000-JA.impact"
295msgstr "System performance may be affected. \n"
296msgid "SUN4V-8000-JA.action"
297msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n"
298#
299# code: SUN4V-8000-KS
300# keys: fault.cpu.ultraSPARC-T2.itlb
301#
302msgid "SUN4V-8000-KS.type"
303msgstr "Fault"
304msgid "SUN4V-8000-KS.severity"
305msgstr "Major"
306msgid "SUN4V-8000-KS.description"
307msgstr "The number of ITLB errors associated with this thread has exceeded acceptable levels.\n  Refer to %s for more information."
308msgid "SUN4V-8000-KS.response"
309msgstr "The fault manager will attempt to remove all threads associated with\nthis resource from service.\n"
310msgid "SUN4V-8000-KS.impact"
311msgstr "System performance is likely to be affected. \n"
312msgid "SUN4V-8000-KS.action"
313msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n"
314#
315# code: SUN4V-8000-L5
316# keys: fault.cpu.ultraSPARC-T2.dtlb
317#
318msgid "SUN4V-8000-L5.type"
319msgstr "Fault"
320msgid "SUN4V-8000-L5.severity"
321msgstr "Major"
322msgid "SUN4V-8000-L5.description"
323msgstr "The number of DTLB errors associated with this thread has exceeded acceptable levels.\n  Refer to %s for more information."
324msgid "SUN4V-8000-L5.response"
325msgstr "The fault manager will attempt to remove all threads associated with\nthis resource from service.\n"
326msgid "SUN4V-8000-L5.impact"
327msgstr "System performance is likely to be affected. \n"
328msgid "SUN4V-8000-L5.action"
329msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n"
330#
331# code: SUN4V-8000-MY
332# keys: fault.cpu.ultraSPARC-T2.icache
333#
334msgid "SUN4V-8000-MY.type"
335msgstr "Fault"
336msgid "SUN4V-8000-MY.severity"
337msgstr "Major"
338msgid "SUN4V-8000-MY.description"
339msgstr "The number of I-cache errors associated with this thread has exceeded acceptable levels.\n  Refer to %s for more information."
340msgid "SUN4V-8000-MY.response"
341msgstr "The fault manager will attempt to remove all threads associated with\nthis resource from service.\n"
342msgid "SUN4V-8000-MY.impact"
343msgstr "System performance is likely to be affected. \n"
344msgid "SUN4V-8000-MY.action"
345msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n"
346#
347# code: SUN4V-8000-N3
348# keys: fault.cpu.ultraSPARC-T2.dcache
349#
350msgid "SUN4V-8000-N3.type"
351msgstr "Fault"
352msgid "SUN4V-8000-N3.severity"
353msgstr "Major"
354msgid "SUN4V-8000-N3.description"
355msgstr "The number of D-cache errors associated with this thread has exceeded acceptable levels.\n  Refer to %s for more information."
356msgid "SUN4V-8000-N3.response"
357msgstr "The fault manager will attempt to remove all threads associated with\nthis resource from service.\n"
358msgid "SUN4V-8000-N3.impact"
359msgstr "System performance is likely to be affected. \n"
360msgid "SUN4V-8000-N3.action"
361msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n"
362#
363# code: SUN4V-8000-PH
364# keys: fault.cpu.ultraSPARC-T2.mau
365#
366msgid "SUN4V-8000-PH.type"
367msgstr "Fault"
368msgid "SUN4V-8000-PH.severity"
369msgstr "Major"
370msgid "SUN4V-8000-PH.description"
371msgstr "The number of modular arithmetic unit errors associated with this unit has exceeded acceptable levels.\n  Refer to %s for more information."
372msgid "SUN4V-8000-PH.response"
373msgstr "Cryptographic software will not use this modular arithmetic unit.\n"
374msgid "SUN4V-8000-PH.impact"
375msgstr "System performance is likely to be affected. \n"
376msgid "SUN4V-8000-PH.action"
377msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n"
378#
379# code: SUN4V-8000-QD
380# keys: fault.cpu.ultraSPARC-T2.l2data-c
381#
382msgid "SUN4V-8000-QD.type"
383msgstr "Fault"
384msgid "SUN4V-8000-QD.severity"
385msgstr "Critical"
386msgid "SUN4V-8000-QD.description"
387msgstr "The number of level 2 cache correctable data errors has exceeded acceptable levels.\n  Refer to %s for more information."
388msgid "SUN4V-8000-QD.response"
389msgstr "No automated response.\n"
390msgid "SUN4V-8000-QD.impact"
391msgstr "System performance is likely to be affected. \n"
392msgid "SUN4V-8000-QD.action"
393msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n"
394#
395# code: SUN4V-8000-R4
396# keys: fault.cpu.ultraSPARC-T2.l2cachetag
397#
398msgid "SUN4V-8000-R4.type"
399msgstr "Fault"
400msgid "SUN4V-8000-R4.severity"
401msgstr "Critical"
402msgid "SUN4V-8000-R4.description"
403msgstr "The number of level 2 cache tag errors has exceeded acceptable levels.\n  Refer to %s for more information."
404msgid "SUN4V-8000-R4.response"
405msgstr "No automated response.\n"
406msgid "SUN4V-8000-R4.impact"
407msgstr "System performance is likely to be affected. \n"
408msgid "SUN4V-8000-R4.action"
409msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n"
410#
411# code: SUN4V-8000-SR
412# keys: fault.cpu.ultraSPARC-T2.l2cachectl
413#
414msgid "SUN4V-8000-SR.type"
415msgstr "Fault"
416msgid "SUN4V-8000-SR.severity"
417msgstr "Critical"
418msgid "SUN4V-8000-SR.description"
419msgstr "The number of level 2 cache control errors has exceeded acceptable levels.\n  Refer to %s for more information."
420msgid "SUN4V-8000-SR.response"
421msgstr "No automated response.\n"
422msgid "SUN4V-8000-SR.impact"
423msgstr "System performance is likely to be affected. System may be unstable.\n"
424msgid "SUN4V-8000-SR.action"
425msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n"
426#
427# code: SUN4V-8000-TC
428# keys: fault.memory.link-u
429#
430msgid "SUN4V-8000-TC.type"
431msgstr "Fault"
432msgid "SUN4V-8000-TC.severity"
433msgstr "Critical"
434msgid "SUN4V-8000-TC.description"
435msgstr "A problem was detected in the interconnect between a memory DIMM module and\nits memory controller. \n  Refer to %s for more information."
436msgid "SUN4V-8000-TC.response"
437msgstr "No automated response.\n"
438msgid "SUN4V-8000-TC.impact"
439msgstr "System performance may be impacted.\n"
440msgid "SUN4V-8000-TC.action"
441msgstr "At convenient time, try reseating the memory module.  If problem persists,\ncontact Sun to schedule part replacement.\n"
442#
443# code: SUN4V-8000-UQ
444# keys: fault.cpu.ultraSPARC-T2.l2data-u
445#
446msgid "SUN4V-8000-UQ.type"
447msgstr "Fault"
448msgid "SUN4V-8000-UQ.severity"
449msgstr "Critical"
450msgid "SUN4V-8000-UQ.description"
451msgstr "The number of level 2 cache uncorrectable data errors has exceeded acceptable levels.\n  Refer to %s for more information."
452msgid "SUN4V-8000-UQ.response"
453msgstr "No automated response.\n"
454msgid "SUN4V-8000-UQ.impact"
455msgstr "System performance is likely to be affected. \n"
456msgid "SUN4V-8000-UQ.action"
457msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n"
458#
459# code: SUN4V-8000-VE
460# keys: fault.cpu.ultraSPARC-T1.l2data-c
461#
462msgid "SUN4V-8000-VE.type"
463msgstr "Fault"
464msgid "SUN4V-8000-VE.severity"
465msgstr "Critical"
466msgid "SUN4V-8000-VE.description"
467msgstr "The number of level 2 cache correctable data errors has exceeded acceptable levels.\n  Refer to %s for more information."
468msgid "SUN4V-8000-VE.response"
469msgstr "No automated response.\n"
470msgid "SUN4V-8000-VE.impact"
471msgstr "System performance is likely to be affected. \n"
472msgid "SUN4V-8000-VE.action"
473msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n"
474#
475# code: SUN4V-8000-WJ
476# keys: fault.cpu.ultraSPARC-T1.l2data-u
477#
478msgid "SUN4V-8000-WJ.type"
479msgstr "Fault"
480msgid "SUN4V-8000-WJ.severity"
481msgstr "Critical"
482msgid "SUN4V-8000-WJ.description"
483msgstr "The number of level 2 cache uncorrectable data errors has exceeded acceptable levels.\n  Refer to %s for more information."
484msgid "SUN4V-8000-WJ.response"
485msgstr "No automated response.\n"
486msgid "SUN4V-8000-WJ.impact"
487msgstr "System performance is likely to be affected. \n"
488msgid "SUN4V-8000-WJ.action"
489msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n"
490#
491# code: SUN4V-8000-X2
492# keys: fault.memory.datapath
493#
494msgid "SUN4V-8000-X2.type"
495msgstr "Fault"
496msgid "SUN4V-8000-X2.severity"
497msgstr "Major"
498msgid "SUN4V-8000-X2.description"
499msgstr "Errors have been detected on multiple memory modules, suggesting that a problem exists somewhere else in the system.\n  Refer to %s for more information."
500msgid "SUN4V-8000-X2.response"
501msgstr "Error reports from the affected components will be logged for examination by Sun.\n"
502msgid "SUN4V-8000-X2.impact"
503msgstr "System performance and stability may be affected. \n"
504msgid "SUN4V-8000-X2.action"
505msgstr "Contact your service provider for further diagnosis.\n"
506#
507# code: SUN4V-8000-YX
508# keys: fault.io.n2.ncu
509#
510msgid "SUN4V-8000-YX.type"
511msgstr "Fault"
512msgid "SUN4V-8000-YX.severity"
513msgstr "Critical"
514msgid "SUN4V-8000-YX.description"
515msgstr "A problem was detected in the NCU subsystem of the N2's SOC\n  Refer to %s for more information."
516msgid "SUN4V-8000-YX.response"
517msgstr "One or more device instances may be disabled\n"
518msgid "SUN4V-8000-YX.impact"
519msgstr "Loss of services provided by the device\ninstances associated with this fault\n"
520msgid "SUN4V-8000-YX.action"
521msgstr "Schedule a repair procedure to replace the affected\ndevice if necessary, or contact Sun for support.\n"
522#
523# code: SUN4V-8001-02
524# keys: fault.io.n2.dmu
525#
526msgid "SUN4V-8001-02.type"
527msgstr "Fault"
528msgid "SUN4V-8001-02.severity"
529msgstr "Critical"
530msgid "SUN4V-8001-02.description"
531msgstr "A problem was detected in the DMU subsystem of the N2's SOC\n  Refer to %s for more information."
532msgid "SUN4V-8001-02.response"
533msgstr "One or more device instances may be disabled\n"
534msgid "SUN4V-8001-02.impact"
535msgstr "Loss of services provided by the device\ninstances associated with this fault\n"
536msgid "SUN4V-8001-02.action"
537msgstr "Schedule a repair procedure to replace the affected\ndevice if necessary, or contact Sun for support.\n"
538#
539# code: SUN4V-8001-1X
540# keys: fault.io.n2.niu
541#
542msgid "SUN4V-8001-1X.type"
543msgstr "Fault"
544msgid "SUN4V-8001-1X.severity"
545msgstr "Critical"
546msgid "SUN4V-8001-1X.description"
547msgstr "A problem was detected in the NIU subsystem of the N2's SOC\n  Refer to %s for more information."
548msgid "SUN4V-8001-1X.response"
549msgstr "One or more device instances may be disabled\n"
550msgid "SUN4V-8001-1X.impact"
551msgstr "Loss of services provided by the device\ninstances associated with this fault\n"
552msgid "SUN4V-8001-1X.action"
553msgstr "Schedule a repair procedure to replace the affected\ndevice if necessary, or contact Sun for support.\n"
554#
555# code: SUN4V-8001-2E
556# keys: fault.io.n2.siu
557#
558msgid "SUN4V-8001-2E.type"
559msgstr "Fault"
560msgid "SUN4V-8001-2E.severity"
561msgstr "Critical"
562msgid "SUN4V-8001-2E.description"
563msgstr "A problem was detected in the SIU subsystem of the N2's SOC\n  Refer to %s for more information."
564msgid "SUN4V-8001-2E.response"
565msgstr "One or more device instances may be disabled\n"
566msgid "SUN4V-8001-2E.impact"
567msgstr "Loss of services provided by the device\ninstances associated with this fault\n"
568msgid "SUN4V-8001-2E.action"
569msgstr "Schedule a repair procedure to replace the affected\ndevice if necessary, or contact Sun for support.\n"
570#
571# code: SUN4V-8001-3J
572# keys: fault.io.n2.soc
573#
574msgid "SUN4V-8001-3J.type"
575msgstr "Fault"
576msgid "SUN4V-8001-3J.severity"
577msgstr "Critical"
578msgid "SUN4V-8001-3J.description"
579msgstr "A problem was detected in N2's SOC\n  Refer to %s for more information."
580msgid "SUN4V-8001-3J.response"
581msgstr "One or more device instances may be disabled\n"
582msgid "SUN4V-8001-3J.impact"
583msgstr "Loss of services provided by the device\ninstances associated with this fault\n"
584msgid "SUN4V-8001-3J.action"
585msgstr "Schedule a repair procedure to replace the affected\ndevice if necessary, or contact Sun for support.\n"
586#
587# code: SUN4V-8001-4C
588# keys: fault.io.n2.crossbar
589#
590msgid "SUN4V-8001-4C.type"
591msgstr "Fault"
592msgid "SUN4V-8001-4C.severity"
593msgstr "Critical"
594msgid "SUN4V-8001-4C.description"
595msgstr "A problem was detected in the crossbar of the N2's SOC\n  Refer to %s for more information."
596msgid "SUN4V-8001-4C.response"
597msgstr "One or more device instances may be disabled\n"
598msgid "SUN4V-8001-4C.impact"
599msgstr "Loss of services provided by the device\ninstances associated with this fault\n"
600msgid "SUN4V-8001-4C.action"
601msgstr "Schedule a repair procedure to replace the affected\ndevice if necessary, or contact Sun for support.\n"
602#
603# code: SUN4V-8001-5Q
604# keys: fault.io.fire.fw-epkt fault.io.fire.sw-epkt fault.io.fire.sw-fw-mismatch
605#
606msgid "SUN4V-8001-5Q.type"
607msgstr "Fault"
608msgid "SUN4V-8001-5Q.severity"
609msgstr "Critical"
610msgid "SUN4V-8001-5Q.description"
611msgstr "An uncorrectable problem was detected in the IO hostbridge in which a mismatch\nin the SW and FW prevents the error to be properly handled.\n  Refer to %s for more information."
612msgid "SUN4V-8001-5Q.response"
613msgstr "One or more device instances may be disabled\n"
614msgid "SUN4V-8001-5Q.impact"
615msgstr "Loss of services provided by the device\ninstances associated with this fault\n"
616msgid "SUN4V-8001-5Q.action"
617msgstr "Schedule a repair procedure to replace the affected\ndevice if necessary, or contact Sun for support.\n"
618#
619# code: SUN4V-8001-64
620# keys: fault.io.vf.ncx
621#
622msgid "SUN4V-8001-64.type"
623msgstr "Fault"
624msgid "SUN4V-8001-64.severity"
625msgstr "Critical"
626msgid "SUN4V-8001-64.description"
627msgstr "An uncorrectable problem was detected in the NCX subsystem.\n  Refer to %s for more information."
628msgid "SUN4V-8001-64.response"
629msgstr "One or more device instances may be disabled\n"
630msgid "SUN4V-8001-64.impact"
631msgstr "Loss of services provided by the device\ninstances associated with this fault\n"
632msgid "SUN4V-8001-64.action"
633msgstr "Schedule a repair procedure to replace the affected\ndevice if necessary, or contact Sun for support.\n"
634#
635# code: SUN4V-8001-7R
636# keys: fault.memory.link-f
637#
638msgid "SUN4V-8001-7R.type"
639msgstr "Fault"
640msgid "SUN4V-8001-7R.severity"
641msgstr "Major"
642msgid "SUN4V-8001-7R.description"
643msgstr "A problem was detected in the interconnect between a memory DIMM module and\nits memory controller.  A lane failover has taken place.\n  Refer to %s for more information."
644msgid "SUN4V-8001-7R.response"
645msgstr "No automated response.\n"
646msgid "SUN4V-8001-7R.impact"
647msgstr "System performance may be impacted.\n"
648msgid "SUN4V-8001-7R.action"
649msgstr "At convenient time, try reseating the memory module(s).  If problem persists,\ncontact Sun to schedule part replacement.\n"
650#
651# code: SUN4V-8001-8H
652# keys: fault.cpu.ultraSPARC-T2plus.ireg
653#
654msgid "SUN4V-8001-8H.type"
655msgstr "Fault"
656msgid "SUN4V-8001-8H.severity"
657msgstr "Minor"
658msgid "SUN4V-8001-8H.description"
659msgstr "The number of integer register errors associated with this thread has exceeded acceptable levels.\n  Refer to %s for more information."
660msgid "SUN4V-8001-8H.response"
661msgstr "The fault manager will attempt to remove the affected thread\nfrom service.\n"
662msgid "SUN4V-8001-8H.impact"
663msgstr "System performance may be affected. \n"
664msgid "SUN4V-8001-8H.action"
665msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n"
666#
667# code: SUN4V-8001-9D
668# keys: fault.cpu.ultraSPARC-T2plus.freg
669#
670msgid "SUN4V-8001-9D.type"
671msgstr "Fault"
672msgid "SUN4V-8001-9D.severity"
673msgstr "Minor"
674msgid "SUN4V-8001-9D.description"
675msgstr "The number of floating register errors associated with this thread has exceeded acceptable levels.\n  Refer to %s for more information."
676msgid "SUN4V-8001-9D.response"
677msgstr "The fault manager will attempt to remove the affected thread\nfrom service.\n"
678msgid "SUN4V-8001-9D.impact"
679msgstr "System performance may be affected. \n"
680msgid "SUN4V-8001-9D.action"
681msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n"
682#
683# code: SUN4V-8001-AY
684# keys: fault.cpu.ultraSPARC-T2plus.misc_reg
685#
686msgid "SUN4V-8001-AY.type"
687msgstr "Fault"
688msgid "SUN4V-8001-AY.severity"
689msgstr "Minor"
690msgid "SUN4V-8001-AY.description"
691msgstr "The number of ancillary register errors associated with this thread has exceeded acceptable levels.\n  Refer to %s for more information."
692msgid "SUN4V-8001-AY.response"
693msgstr "The fault manager will attempt to remove the affected thread\nfrom service.\n"
694msgid "SUN4V-8001-AY.impact"
695msgstr "System performance may be affected. \n"
696msgid "SUN4V-8001-AY.action"
697msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n"
698#
699# code: SUN4V-8001-C3
700# keys: fault.cpu.ultraSPARC-T2plus.itlb
701#
702msgid "SUN4V-8001-C3.type"
703msgstr "Fault"
704msgid "SUN4V-8001-C3.severity"
705msgstr "Major"
706msgid "SUN4V-8001-C3.description"
707msgstr "The number of ITLB errors associated with this thread has exceeded acceptable levels.\n  Refer to %s for more information."
708msgid "SUN4V-8001-C3.response"
709msgstr "The fault manager will attempt to remove all threads associated with\nthis resource from service.\n"
710msgid "SUN4V-8001-C3.impact"
711msgstr "System performance is likely to be affected. \n"
712msgid "SUN4V-8001-C3.action"
713msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n"
714#
715# code: SUN4V-8001-DS
716# keys: fault.cpu.ultraSPARC-T2plus.dtlb
717#
718msgid "SUN4V-8001-DS.type"
719msgstr "Fault"
720msgid "SUN4V-8001-DS.severity"
721msgstr "Major"
722msgid "SUN4V-8001-DS.description"
723msgstr "The number of DTLB errors associated with this thread has exceeded acceptable levels.\n  Refer to %s for more information."
724msgid "SUN4V-8001-DS.response"
725msgstr "The fault manager will attempt to remove all threads associated with\nthis resource from service.\n"
726msgid "SUN4V-8001-DS.impact"
727msgstr "System performance is likely to be affected. \n"
728msgid "SUN4V-8001-DS.action"
729msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n"
730#
731# code: SUN4V-8001-E5
732# keys: fault.cpu.ultraSPARC-T2plus.icache
733#
734msgid "SUN4V-8001-E5.type"
735msgstr "Fault"
736msgid "SUN4V-8001-E5.severity"
737msgstr "Major"
738msgid "SUN4V-8001-E5.description"
739msgstr "The number of I-cache errors associated with this thread has exceeded acceptable levels.\n  Refer to %s for more information."
740msgid "SUN4V-8001-E5.response"
741msgstr "The fault manager will attempt to remove all threads associated with\nthis resource from service.\n"
742msgid "SUN4V-8001-E5.impact"
743msgstr "System performance is likely to be affected. \n"
744msgid "SUN4V-8001-E5.action"
745msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n"
746#
747# code: SUN4V-8001-FP
748# keys: fault.cpu.ultraSPARC-T2plus.dcache
749#
750msgid "SUN4V-8001-FP.type"
751msgstr "Fault"
752msgid "SUN4V-8001-FP.severity"
753msgstr "Major"
754msgid "SUN4V-8001-FP.description"
755msgstr "The number of D-cache errors associated with this thread has exceeded acceptable levels.\n  Refer to %s for more information."
756msgid "SUN4V-8001-FP.response"
757msgstr "The fault manager will attempt to remove all threads associated with\nthis resource from service.\n"
758msgid "SUN4V-8001-FP.impact"
759msgstr "System performance is likely to be affected. \n"
760msgid "SUN4V-8001-FP.action"
761msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n"
762#
763# code: SUN4V-8001-GA
764# keys: fault.cpu.ultraSPARC-T2plus.mau
765#
766msgid "SUN4V-8001-GA.type"
767msgstr "Fault"
768msgid "SUN4V-8001-GA.severity"
769msgstr "Major"
770msgid "SUN4V-8001-GA.description"
771msgstr "The number of modular arithmetic unit errors associated with this thread has exceeded acceptable levels.\n  Refer to %s for more information."
772msgid "SUN4V-8001-GA.response"
773msgstr "Cryptographic software will not use this modular arithmetic unit.\n\n"
774msgid "SUN4V-8001-GA.impact"
775msgstr "System performance is likely to be affected. \n"
776msgid "SUN4V-8001-GA.action"
777msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n"
778#
779# code: SUN4V-8001-HJ
780# keys: fault.cpu.ultraSPARC-T2plus.l2data-c
781#
782msgid "SUN4V-8001-HJ.type"
783msgstr "Fault"
784msgid "SUN4V-8001-HJ.severity"
785msgstr "Critical"
786msgid "SUN4V-8001-HJ.description"
787msgstr "The number of level 2 cache correctable data errors has exceeded acceptable levels.\n  Refer to %s for more information."
788msgid "SUN4V-8001-HJ.response"
789msgstr "No automated response.\n"
790msgid "SUN4V-8001-HJ.impact"
791msgstr "System performance is likely to be affected. \n"
792msgid "SUN4V-8001-HJ.action"
793msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n"
794#
795# code: SUN4V-8001-JE
796# keys: fault.cpu.ultraSPARC-T2plus.l2cachetag
797#
798msgid "SUN4V-8001-JE.type"
799msgstr "Fault"
800msgid "SUN4V-8001-JE.severity"
801msgstr "Critical"
802msgid "SUN4V-8001-JE.description"
803msgstr "The number of level 2 cache tag errors has exceeded acceptable levels.\n  Refer to %s for more information."
804msgid "SUN4V-8001-JE.response"
805msgstr "No automated response.\n"
806msgid "SUN4V-8001-JE.impact"
807msgstr "System performance is likely to be affected. \n"
808msgid "SUN4V-8001-JE.action"
809msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n"
810#
811# code: SUN4V-8001-KX
812# keys: fault.cpu.ultraSPARC-T2plus.l2cachectl
813#
814msgid "SUN4V-8001-KX.type"
815msgstr "Fault"
816msgid "SUN4V-8001-KX.severity"
817msgstr "Critical"
818msgid "SUN4V-8001-KX.description"
819msgstr "The number of level 2 cache control errors has exceeded acceptable levels.\n  Refer to %s for more information."
820msgid "SUN4V-8001-KX.response"
821msgstr "No automated response.\n"
822msgid "SUN4V-8001-KX.impact"
823msgstr "System performance is likely to be affected. System may be unstable.\n"
824msgid "SUN4V-8001-KX.action"
825msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n"
826#
827# code: SUN4V-8001-L2
828# keys: fault.cpu.ultraSPARC-T2plus.l2data-u
829#
830msgid "SUN4V-8001-L2.type"
831msgstr "Fault"
832msgid "SUN4V-8001-L2.severity"
833msgstr "Critical"
834msgid "SUN4V-8001-L2.description"
835msgstr "The number of level 2 cache uncorrectable data errors has exceeded acceptable levels.\n  Refer to %s for more information."
836msgid "SUN4V-8001-L2.response"
837msgstr "No automated response.\n"
838msgid "SUN4V-8001-L2.impact"
839msgstr "System performance is likely to be affected. \n"
840msgid "SUN4V-8001-L2.action"
841msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n"
842#
843# code: SUN4V-8001-MR
844# keys: fault.cpu.ultraSPARC-T2plus.lfu-f
845#
846msgid "SUN4V-8001-MR.type"
847msgstr "Fault"
848msgid "SUN4V-8001-MR.severity"
849msgstr "Major"
850msgid "SUN4V-8001-MR.description"
851msgstr "A CPU chip's Link Framing Unit has stopped using a bad lane.\n  Refer to %s for more information."
852msgid "SUN4V-8001-MR.response"
853msgstr "No other automated response.\n"
854msgid "SUN4V-8001-MR.impact"
855msgstr "The system's capacity to correct transmission errors between CPU chips has been reduced.\n"
856msgid "SUN4V-8001-MR.action"
857msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n"
858#
859# code: SUN4V-8001-N4
860# keys: fault.cpu.ultraSPARC-T2plus.lfu-p
861#
862msgid "SUN4V-8001-N4.type"
863msgstr "Fault"
864msgid "SUN4V-8001-N4.severity"
865msgstr "Major"
866msgid "SUN4V-8001-N4.description"
867msgstr "A CPU chip's Link Framing Unit has encountered a protocol error.\n  Refer to %s for more information."
868msgid "SUN4V-8001-N4.response"
869msgstr "No automated response.\n"
870msgid "SUN4V-8001-N4.impact"
871msgstr "The system has most likely taken a fatal reset.\n"
872msgid "SUN4V-8001-N4.action"
873msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n"
874#
875# code: SUN4V-8001-PQ
876# keys: fault.cpu.ultraSPARC-T2plus.lfu-u
877#
878msgid "SUN4V-8001-PQ.type"
879msgstr "Fault"
880msgid "SUN4V-8001-PQ.severity"
881msgstr "Major"
882msgid "SUN4V-8001-PQ.description"
883msgstr "A CPU chip's Link Framing Unit has encountered an unrecoverable lane failure.\n  Refer to %s for more information."
884msgid "SUN4V-8001-PQ.response"
885msgstr "No automated response.\n"
886msgid "SUN4V-8001-PQ.impact"
887msgstr "The system's integrity is seriously compromised.\n"
888msgid "SUN4V-8001-PQ.action"
889msgstr "Do not rely on this system for mission-critical tasks.\nSchedule a repair procedure to replace the affected resource, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n"
890#
891# code: SUN4V-8001-QC
892# keys: fault.asic.ultraSPARC-T2plus.interconnect.opu-u
893#
894msgid "SUN4V-8001-QC.type"
895msgstr "Fault"
896msgid "SUN4V-8001-QC.severity"
897msgstr "Critical"
898msgid "SUN4V-8001-QC.description"
899msgstr "The ultraSPARC-T2plus Coherency Interconnect has detected a fatal\ninternal problem.\n  Refer to %s for more information."
900msgid "SUN4V-8001-QC.response"
901msgstr "No automated reponse.\n"
902msgid "SUN4V-8001-QC.impact"
903msgstr "The system's integrity is compromised.\n"
904msgid "SUN4V-8001-QC.action"
905msgstr "Schedule a repair procedure to replace the affected component, the identity\nof which can be determined by using fmdump -v -u <EVENT_ID>.\n"
906#
907# code: SUN4V-8001-R3
908# keys: fault.asic.ultraSPARC-T2plus.interconnect.opu-c
909#
910msgid "SUN4V-8001-R3.type"
911msgstr "Fault"
912msgid "SUN4V-8001-R3.severity"
913msgstr "Major"
914msgid "SUN4V-8001-R3.description"
915msgstr "The ultraSPARC-T2plus Coherency Interconnect has detected an internal problem.\n  Refer to %s for more information."
916msgid "SUN4V-8001-R3.response"
917msgstr "No automated reponse.\n"
918msgid "SUN4V-8001-R3.impact"
919msgstr "The system's integrity is compromised.\n"
920msgid "SUN4V-8001-R3.action"
921msgstr "Schedule a repair procedure to replace the affected component, the identity\nof which can be determined by using fmdump -v -u <EVENT_ID>.\n"
922#
923# code: SUN4V-8001-SY
924# keys: fault.cpu.ultraSPARC-T2plus.chip
925#
926msgid "SUN4V-8001-SY.type"
927msgstr "Fault"
928msgid "SUN4V-8001-SY.severity"
929msgstr "Critical"
930msgid "SUN4V-8001-SY.description"
931msgstr "An ultraSPARC-T2plus Interconnect has detected a fatal communication\nproblem with a CPU.\n  Refer to %s for more information."
932msgid "SUN4V-8001-SY.response"
933msgstr "No automated reponse.\n"
934msgid "SUN4V-8001-SY.impact"
935msgstr "The system's integrity is seriously compromised.\n"
936msgid "SUN4V-8001-SY.action"
937msgstr "Schedule a repair procedure to replace the affected component, the identity\nof which can be determined by using fmdump -v -u <EVENT_ID>.\n"
938#
939# code: SUN4V-8001-TD
940# keys: fault.asic.ultraSPARC-T2plus.interconnect.lfu-c fault.cpu.ultraSPARC-T2plus.chip
941#
942msgid "SUN4V-8001-TD.type"
943msgstr "Fault"
944msgid "SUN4V-8001-TD.severity"
945msgstr "Minor"
946msgid "SUN4V-8001-TD.description"
947msgstr "The number of CRC errors between an ultraSPARC-T2plus\nCoherency Interconnect and a CPU has exceeded acceptable levels.\n  Refer to %s for more information."
948msgid "SUN4V-8001-TD.response"
949msgstr "No automated reponse.\n"
950msgid "SUN4V-8001-TD.impact"
951msgstr "The system's integrity is seriously compromised.\n"
952msgid "SUN4V-8001-TD.action"
953msgstr "Schedule a repair procedure to replace the affected component, the identity\nof which can be determined by using fmdump -v -u <EVENT_ID>.\n"
954#
955# code: SUN4V-8001-UH
956# keys: fault.asic.ultraSPARC-T2plus.interconnect.lfu-f fault.cpu.ultraSPARC-T2plus.chip
957#
958msgid "SUN4V-8001-UH.type"
959msgstr "Fault"
960msgid "SUN4V-8001-UH.severity"
961msgstr "Major"
962msgid "SUN4V-8001-UH.description"
963msgstr "An ultraSPARC-T2plus Coherency Interconnect has detected a single-lane\nfailure communicating with a CPU.\n  Refer to %s for more information."
964msgid "SUN4V-8001-UH.response"
965msgstr "No automated reponse.\n"
966msgid "SUN4V-8001-UH.impact"
967msgstr "The system's performance may be impacted.\n"
968msgid "SUN4V-8001-UH.action"
969msgstr "Schedule a repair procedure to replace the affected component, the identity\nof which can be determined by using fmdump -v -u <EVENT_ID>.\n"
970#
971# code: SUN4V-8001-VA
972# keys: fault.asic.ultraSPARC-T2plus.interconnect.lfu-u fault.cpu.ultraSPARC-T2plus.chip
973#
974msgid "SUN4V-8001-VA.type"
975msgstr "Fault"
976msgid "SUN4V-8001-VA.severity"
977msgstr "Critical"
978msgid "SUN4V-8001-VA.description"
979msgstr "An ultraSPARC-T2plus Coherency Interconnect has detected a fatal\nfault commnicating with a CPU.\n  Refer to %s for more information."
980msgid "SUN4V-8001-VA.response"
981msgstr "No automated reponse.\n"
982msgid "SUN4V-8001-VA.impact"
983msgstr "The system's integrity is seriously compromised.\n"
984msgid "SUN4V-8001-VA.action"
985msgstr "Schedule a repair procedure to replace the affected component, the identity\nof which can be determined by using fmdump -v -u <EVENT_ID>.\n"
986#
987# code: SUN4V-8001-WP
988# keys: fault.asic.ultraSPARC-T2plus.interconnect.lfu-u
989#
990msgid "SUN4V-8001-WP.type"
991msgstr "Fault"
992msgid "SUN4V-8001-WP.severity"
993msgstr "Critical"
994msgid "SUN4V-8001-WP.description"
995msgstr "An ultraSPARC-T2plus Coherency Interconnect has detected a fatal internal\nfault and has automatically reset.\n  Refer to %s for more information."
996msgid "SUN4V-8001-WP.response"
997msgstr "No automated reponse.\n"
998msgid "SUN4V-8001-WP.impact"
999msgstr "The system's integrity is seriously compromised.\n"
1000msgid "SUN4V-8001-WP.action"
1001msgstr "Schedule a repair procedure to replace the affected component, the identity\nof which can be determined by using fmdump -v -u <EVENT_ID>.\n"
1002#
1003# code: SUN4V-8001-X5
1004# keys: fault.asic.ultraSPARC-T2plus.interconnect.gpd-u fault.cpu.ultraSPARC-T2plus.chip
1005#
1006msgid "SUN4V-8001-X5.type"
1007msgstr "Fault"
1008msgid "SUN4V-8001-X5.severity"
1009msgstr "Critical"
1010msgid "SUN4V-8001-X5.description"
1011msgstr "An ultraSPARC-T2plus Coherency Interconnect has detected a fatal communication\nfault with a CPU.\n  Refer to %s for more information."
1012msgid "SUN4V-8001-X5.response"
1013msgstr "No automated reponse.\n"
1014msgid "SUN4V-8001-X5.impact"
1015msgstr "The system's performance may be compromised.\n"
1016msgid "SUN4V-8001-X5.action"
1017msgstr "Schedule a repair procedure to replace the affected component, the identity\nof which can be determined by using fmdump -v -u <EVENT_ID>.\n"
1018#
1019# code: SUN4V-8001-YS
1020# keys: fault.asic.ultraSPARC-T2plus.interconnect.gpd-c fault.cpu.ultraSPARC-T2plus.chip
1021#
1022msgid "SUN4V-8001-YS.type"
1023msgstr "Fault"
1024msgid "SUN4V-8001-YS.severity"
1025msgstr "Major"
1026msgid "SUN4V-8001-YS.description"
1027msgstr "An ultraSPARC-T2plus Coherency Interconnect has detected a fault\ncommunicating with a CPU.\n  Refer to %s for more information."
1028msgid "SUN4V-8001-YS.response"
1029msgstr "No automated reponse.\n"
1030msgid "SUN4V-8001-YS.impact"
1031msgstr "The system's integrity may be seriously compromised.\n"
1032msgid "SUN4V-8001-YS.action"
1033msgstr "Schedule a repair procedure to replace the affected component, the identity\nof which can be determined by using fmdump -v -u <EVENT_ID>.\n"
1034#
1035# code: SUN4V-8002-0C
1036# keys: fault.asic.ultraSPARC-T2plus.interconnect.gpd-c
1037#
1038msgid "SUN4V-8002-0C.type"
1039msgstr "Fault"
1040msgid "SUN4V-8002-0C.severity"
1041msgstr "Major"
1042msgid "SUN4V-8002-0C.description"
1043msgstr "The ultraSPARC-T2plus Interconnect has detected a fault communicating\nwith the service processor.\n  Refer to %s for more information."
1044msgid "SUN4V-8002-0C.response"
1045msgstr "No automated reponse.\n"
1046msgid "SUN4V-8002-0C.impact"
1047msgstr "The system's performance may be impacted.\n"
1048msgid "SUN4V-8002-0C.action"
1049msgstr "Schedule a repair procedure to replace the affected component, the identity\nof which can be determined by using fmdump -v -u <EVENT_ID>.\n"
1050#
1051# code: SUN4V-8002-1Q
1052# keys: fault.asic.fpga fault.asic.ultraSPARC-T2plus.interconnect.gpd-c
1053#
1054msgid "SUN4V-8002-1Q.type"
1055msgstr "Fault"
1056msgid "SUN4V-8002-1Q.severity"
1057msgstr "Major"
1058msgid "SUN4V-8002-1Q.description"
1059msgstr "ultraSPARC-T2plus Coherency Interconnect detected a fault on the LPC bus.\n  Refer to %s for more information."
1060msgid "SUN4V-8002-1Q.response"
1061msgstr "No automated reponse.\n"
1062msgid "SUN4V-8002-1Q.impact"
1063msgstr "The system's performance may be impacted.\n"
1064msgid "SUN4V-8002-1Q.action"
1065msgstr "Schedule a repair procedure to replace the affected component, the identity\nof which can be determined by using fmdump -v -u <EVENT_ID>.\n"
1066#
1067# code: SUN4V-8002-24
1068# keys: fault.asic.ultraSPARC-T2plus.interconnect.asu
1069#
1070msgid "SUN4V-8002-24.type"
1071msgstr "Fault"
1072msgid "SUN4V-8002-24.severity"
1073msgstr "Critical"
1074msgid "SUN4V-8002-24.description"
1075msgstr "An ultraSPARC-T2plus Coherency Interconnect has detected a fatal fault.\n  Refer to %s for more information."
1076msgid "SUN4V-8002-24.response"
1077msgstr "No automated reponse.\n"
1078msgid "SUN4V-8002-24.impact"
1079msgstr "The system's integrity is seriously compromised.\n"
1080msgid "SUN4V-8002-24.action"
1081msgstr "Schedule a repair procedure to replace the affected component, the identity\nof which can be determined by using fmdump -v -u <EVENT_ID>.\n"
1082#
1083# code: SUN4V-8002-3R
1084# keys: fault.memory.dimm-page-retires-excessive
1085#
1086msgid "SUN4V-8002-3R.type"
1087msgstr "Fault"
1088msgid "SUN4V-8002-3R.severity"
1089msgstr "Major"
1090msgid "SUN4V-8002-3R.description"
1091msgstr "The number of correctable errors associated with this memory module has exceeded acceptable levels.\n  Refer to %s for more information."
1092msgid "SUN4V-8002-3R.response"
1093msgstr "Pages of memory associated with this memory module have been removed from service, up to a limit which has now been reached.\n"
1094msgid "SUN4V-8002-3R.impact"
1095msgstr "Total system memory capacity has been reduced.\n"
1096msgid "SUN4V-8002-3R.action"
1097msgstr "Schedule a repair procedure to replace the DIMM.  Use fmadm faulty to identify the DIMM to replace.\n"
1098#
1099# code: SUN4V-8002-42
1100# keys: fault.memory.dimm-ue-imminent
1101#
1102msgid "SUN4V-8002-42.type"
1103msgstr "Fault"
1104msgid "SUN4V-8002-42.severity"
1105msgstr "Critical"
1106msgid "SUN4V-8002-42.description"
1107msgstr "A pattern of correctable errors has been observed suggesting the potential exists that an uncorrectable error may occur.\n  Refer to %s for more information."
1108msgid "SUN4V-8002-42.response"
1109msgstr "None at this time.\n"
1110msgid "SUN4V-8002-42.impact"
1111msgstr "None at this time. However, the potential uncorrectable error warrants proactive service action to avoid any unplanned system outages.\n"
1112msgid "SUN4V-8002-42.action"
1113msgstr "Schedule a repair procedure to replace the DIMM. Use fmadm faulty to identify the DIMM to replace.\n"
1114#
1115# code: SUN4V-8002-5X
1116# keys: fault.memory.dram-ue-imminent
1117#
1118msgid "SUN4V-8002-5X.type"
1119msgstr "Fault"
1120msgid "SUN4V-8002-5X.severity"
1121msgstr "Critical"
1122msgid "SUN4V-8002-5X.description"
1123msgstr "A pattern of correctable errors has been observed suggesting the potential exists that an uncorrectable error may occur.\n  Refer to %s for more information."
1124msgid "SUN4V-8002-5X.response"
1125msgstr "None at this time.\n"
1126msgid "SUN4V-8002-5X.impact"
1127msgstr "None at this time. However, the potential uncorrectable error warrants proactive service action to avoid any unplanned system outages.\n"
1128msgid "SUN4V-8002-5X.action"
1129msgstr "Schedule a repair procedure to replace the DIMM. Use fmadm faulty to identify the DIMM to replace.\n"
1130#
1131# code: SUN4V-8002-6E
1132# keys: fault.cpu.generic-sparc.strand
1133#
1134msgid "SUN4V-8002-6E.type"
1135msgstr "Fault"
1136msgid "SUN4V-8002-6E.severity"
1137msgstr "Major"
1138msgid "SUN4V-8002-6E.description"
1139msgstr "The number of correctable errors associated with this strand has exceeded acceptable levels.\n  Refer to %s for more information."
1140msgid "SUN4V-8002-6E.response"
1141msgstr "The fault manager will attempt to remove the affected strand\nfrom service.\n"
1142msgid "SUN4V-8002-6E.impact"
1143msgstr "System performance may be affected. \n"
1144msgid "SUN4V-8002-6E.action"
1145msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using 'fmadm faulty'.\n"
1146#
1147# code: SUN4V-8002-7J
1148# keys: fault.cpu.generic-sparc.strand-nr
1149#
1150msgid "SUN4V-8002-7J.type"
1151msgstr "Fault"
1152msgid "SUN4V-8002-7J.severity"
1153msgstr "Major"
1154msgid "SUN4V-8002-7J.description"
1155msgstr "The number of correctable errors in internal memory associated with this strand have exceeded acceptable levels.\n  Refer to %s for more information."
1156msgid "SUN4V-8002-7J.response"
1157msgstr "The system may attempt to avoid using internal memory associated with this\nstrand.\n"
1158msgid "SUN4V-8002-7J.impact"
1159msgstr "System performance may be affected. \n"
1160msgid "SUN4V-8002-7J.action"
1161msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using 'fmadm faulty'.\n"
1162#
1163# code: SUN4V-8002-8S
1164# keys: fault.cpu.generic-sparc.strand-uc
1165#
1166msgid "SUN4V-8002-8S.type"
1167msgstr "Fault"
1168msgid "SUN4V-8002-8S.severity"
1169msgstr "Critical"
1170msgid "SUN4V-8002-8S.description"
1171msgstr "This strand has encountered an uncorrectable error.\n  Refer to %s for more information."
1172msgid "SUN4V-8002-8S.response"
1173msgstr "The fault manager will attempt to remove the affected strand\nfrom service.\n"
1174msgid "SUN4V-8002-8S.impact"
1175msgstr "System performance may be affected. \n"
1176msgid "SUN4V-8002-8S.action"
1177msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using 'fmadm faulty'.\n"
1178#
1179# code: SUN4V-8002-95
1180# keys: fault.cpu.generic-sparc.strand-uc-nr
1181#
1182msgid "SUN4V-8002-95.type"
1183msgstr "Fault"
1184msgid "SUN4V-8002-95.severity"
1185msgstr "Critical"
1186msgid "SUN4V-8002-95.description"
1187msgstr "Internal memory associated with this strand has encountered an uncorrectable error.\n  Refer to %s for more information."
1188msgid "SUN4V-8002-95.response"
1189msgstr "The system may attempt to avoid using internal memory associated with\nthis strand.\n"
1190msgid "SUN4V-8002-95.impact"
1191msgstr "System performance may be affected. \n"
1192msgid "SUN4V-8002-95.action"
1193msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using 'fmadm faulty'.\n"
1194#
1195# code: SUN4V-8002-AP
1196# keys: fault.cpu.generic-sparc.core
1197#
1198msgid "SUN4V-8002-AP.type"
1199msgstr "Fault"
1200msgid "SUN4V-8002-AP.severity"
1201msgstr "Major"
1202msgid "SUN4V-8002-AP.description"
1203msgstr "The number of correctable errors associated with this core has exceeded acceptable levels.\n  Refer to %s for more information."
1204msgid "SUN4V-8002-AP.response"
1205msgstr "The fault manager will attempt to remove all strands associated with\nthis resource from service.\n"
1206msgid "SUN4V-8002-AP.impact"
1207msgstr "System performance may be affected. \n"
1208msgid "SUN4V-8002-AP.action"
1209msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using 'fmadm faulty'.\n"
1210#
1211# code: SUN4V-8002-CA
1212# keys: fault.cpu.generic-sparc.core-nr
1213#
1214msgid "SUN4V-8002-CA.type"
1215msgstr "Fault"
1216msgid "SUN4V-8002-CA.severity"
1217msgstr "Major"
1218msgid "SUN4V-8002-CA.description"
1219msgstr "The number of correctable errors in internal memory associated with this core have exceeded acceptable levels.\n  Refer to %s for more information."
1220msgid "SUN4V-8002-CA.response"
1221msgstr "The system may attempt to avoid using internal memory associated with this\ncore.\n"
1222msgid "SUN4V-8002-CA.impact"
1223msgstr "System performance may be affected. \n"
1224msgid "SUN4V-8002-CA.action"
1225msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using 'fmadm faulty'.\n"
1226#
1227# code: SUN4V-8002-DH
1228# keys: fault.cpu.generic-sparc.core-uc
1229#
1230msgid "SUN4V-8002-DH.type"
1231msgstr "Fault"
1232msgid "SUN4V-8002-DH.severity"
1233msgstr "Critical"
1234msgid "SUN4V-8002-DH.description"
1235msgstr "This core has encountered an uncorrectable error.\n  Refer to %s for more information."
1236msgid "SUN4V-8002-DH.response"
1237msgstr "The fault manager will attempt to remove all strands associated with\nthis resource from service.\n"
1238msgid "SUN4V-8002-DH.impact"
1239msgstr "System performance may be affected. \n"
1240msgid "SUN4V-8002-DH.action"
1241msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using 'fmadm faulty'.\n"
1242#
1243# code: SUN4V-8002-ED
1244# keys: fault.cpu.generic-sparc.core-uc-nr
1245#
1246msgid "SUN4V-8002-ED.type"
1247msgstr "Fault"
1248msgid "SUN4V-8002-ED.severity"
1249msgstr "Critical"
1250msgid "SUN4V-8002-ED.description"
1251msgstr "An uncorrectable error has occurred in internal memory associated with this core.\n  Refer to %s for more information."
1252msgid "SUN4V-8002-ED.response"
1253msgstr "The system may attempt to avoid using internal memory associated with this\ncore.\n"
1254msgid "SUN4V-8002-ED.impact"
1255msgstr "System performance may be affected. \n"
1256msgid "SUN4V-8002-ED.action"
1257msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using 'fmadm faulty'.\n"
1258#
1259# code: SUN4V-8002-FY
1260# keys: fault.cpu.generic-sparc.chip
1261#
1262msgid "SUN4V-8002-FY.type"
1263msgstr "Fault"
1264msgid "SUN4V-8002-FY.severity"
1265msgstr "Critical"
1266msgid "SUN4V-8002-FY.description"
1267msgstr "The number of chip-level correctable errors has exceeded acceptable levels.\n  Refer to %s for more information."
1268msgid "SUN4V-8002-FY.response"
1269msgstr "No automated response.\n"
1270msgid "SUN4V-8002-FY.impact"
1271msgstr "System performance may be affected. \n"
1272msgid "SUN4V-8002-FY.action"
1273msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using 'fmadm faulty'.\n"
1274#
1275# code: SUN4V-8002-G3
1276# keys: fault.cpu.generic-sparc.chip-nr
1277#
1278msgid "SUN4V-8002-G3.type"
1279msgstr "Fault"
1280msgid "SUN4V-8002-G3.severity"
1281msgstr "Critical"
1282msgid "SUN4V-8002-G3.description"
1283msgstr "The number of correctable errors in internal memory associated with this chip have exceeded acceptable levels.\n  Refer to %s for more information."
1284msgid "SUN4V-8002-G3.response"
1285msgstr "The system may attempt to avoid using internal memory associated with this\nchip.\n"
1286msgid "SUN4V-8002-G3.impact"
1287msgstr "System performance may be affected. \n"
1288msgid "SUN4V-8002-G3.action"
1289msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using 'fmadm faulty'.\n"
1290#
1291# code: SUN4V-8002-HR
1292# keys: fault.cpu.generic-sparc.chip-uc
1293#
1294msgid "SUN4V-8002-HR.type"
1295msgstr "Fault"
1296msgid "SUN4V-8002-HR.severity"
1297msgstr "Critical"
1298msgid "SUN4V-8002-HR.description"
1299msgstr "This chip has encountered a chip-level uncorrectable error.\n  Refer to %s for more information."
1300msgid "SUN4V-8002-HR.response"
1301msgstr "The system will attempt to retire all strands in this chip.\n"
1302msgid "SUN4V-8002-HR.impact"
1303msgstr "System performance may be affected. \n"
1304msgid "SUN4V-8002-HR.action"
1305msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using 'fmadm faulty'.\n"
1306#
1307# code: SUN4V-8002-J4
1308# keys: fault.cpu.generic-sparc.chip-uc-nr
1309#
1310msgid "SUN4V-8002-J4.type"
1311msgstr "Fault"
1312msgid "SUN4V-8002-J4.severity"
1313msgstr "Critical"
1314msgid "SUN4V-8002-J4.description"
1315msgstr "Internal memory associated with this chip has encountered an uncorrectable\nerror.\n  Refer to %s for more information."
1316msgid "SUN4V-8002-J4.response"
1317msgstr "The system may attempt to avoid using internal memory associated with this\nchip.\n"
1318msgid "SUN4V-8002-J4.impact"
1319msgstr "System performance may be affected. \n"
1320msgid "SUN4V-8002-J4.action"
1321msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using 'fmadm faulty'.\n"
1322#
1323# code: SUN4V-8002-KQ
1324# keys: fault.cpu.generic-sparc.c2c
1325#
1326msgid "SUN4V-8002-KQ.type"
1327msgstr "Fault"
1328msgid "SUN4V-8002-KQ.severity"
1329msgstr "Major"
1330msgid "SUN4V-8002-KQ.description"
1331msgstr "The number of chip-to-chip recoverable errors has exceeded acceptable levels.\n  Refer to %s for more information."
1332msgid "SUN4V-8002-KQ.response"
1333msgstr "No automated response.\n"
1334msgid "SUN4V-8002-KQ.impact"
1335msgstr "System performance may be affected.\n"
1336msgid "SUN4V-8002-KQ.action"
1337msgstr "Schedule a repair procedure to replace the affected resource(s), the identity of which can be determined using 'fmadm faulty'.\n"
1338#
1339# code: SUN4V-8002-LC
1340# keys: fault.cpu.generic-sparc.c2c-failover
1341#
1342msgid "SUN4V-8002-LC.type"
1343msgstr "Fault"
1344msgid "SUN4V-8002-LC.severity"
1345msgstr "Major"
1346msgid "SUN4V-8002-LC.description"
1347msgstr "A CRC error has occurred in the interconnect between two CPU chips.\nWhile no data has been lost, a lane failover has taken place.\n  Refer to %s for more information."
1348msgid "SUN4V-8002-LC.response"
1349msgstr "The hardware has automatically reconfigured the link to isolate the\nfailing lane, and successful retransmission of the data has occurred.\n"
1350msgid "SUN4V-8002-LC.impact"
1351msgstr "The system's capacity to correct transmission errors between CPU chips\nhas been reduced.\n"
1352msgid "SUN4V-8002-LC.action"
1353msgstr "Schedule a repair procedure to replace the affected resource(s), the identity of which can be determined using 'fmadm faulty'.\n"
1354#
1355# code: SUN4V-8002-MJ
1356# keys: fault.cpu.generic-sparc.c2c-uc
1357#
1358msgid "SUN4V-8002-MJ.type"
1359msgstr "Fault"
1360msgid "SUN4V-8002-MJ.severity"
1361msgstr "Critical"
1362msgid "SUN4V-8002-MJ.description"
1363msgstr "A chip-to-chip unrecoverable CRC error has occurred.\n  Refer to %s for more information."
1364msgid "SUN4V-8002-MJ.response"
1365msgstr "The system has halted in order to prevent corruption of data.\nNo further automated response.\n"
1366msgid "SUN4V-8002-MJ.impact"
1367msgstr "The system halts and must be restarted.  The integrity of this system has\nbeen compromised.\n"
1368msgid "SUN4V-8002-MJ.action"
1369msgstr "Schedule a repair procedure to replace the affected resource(s), the identity of which can be determined using 'fmadm faulty'.\n"
1370#
1371# code: SUN4V-8002-NE
1372# keys: fault.memory.memlink
1373#
1374msgid "SUN4V-8002-NE.type"
1375msgstr "Fault"
1376msgid "SUN4V-8002-NE.severity"
1377msgstr "Major"
1378msgid "SUN4V-8002-NE.description"
1379msgstr "Recoverable CRC errors have occurred in the interconnect between a\nmemory buffer and its memory controller.  No data has been lost;\nhowever, the number of CRC errors associated with this memory buffer-controller\npair has exceeded acceptable levels.\n  Refer to %s for more information."
1380msgid "SUN4V-8002-NE.response"
1381msgstr "The system has recovered from the CRC errors.\n"
1382msgid "SUN4V-8002-NE.impact"
1383msgstr "System performance may be impacted by a slight reduction in effective\nmemory bandwidth.\n"
1384msgid "SUN4V-8002-NE.action"
1385msgstr "At a convenient time, schedule a repair procedure to replace the affected resource(s), the identity of which can be determined using 'fmadm faulty'.\n"
1386#
1387# code: SUN4V-8002-PX
1388# keys: fault.memory.memlink-failover
1389#
1390msgid "SUN4V-8002-PX.type"
1391msgstr "Fault"
1392msgid "SUN4V-8002-PX.severity"
1393msgstr "Major"
1394msgid "SUN4V-8002-PX.description"
1395msgstr "A CRC error has occurred in the interconnect between a memory buffer and\nits memory controller.  While no data has been lost, a lane failover\nhas taken place.\n  Refer to %s for more information."
1396msgid "SUN4V-8002-PX.response"
1397msgstr "The hardware has automatically reconfigured the link to isolate the\nfailing lane, and successful retransmission of the data has occurred.\n"
1398msgid "SUN4V-8002-PX.impact"
1399msgstr "The system's capacity to correct transmission errors between the memory\nDIMM and its memory controller has been reduced.\n"
1400msgid "SUN4V-8002-PX.action"
1401msgstr "At your earliest convenience, schedule a repair procedure to replace the\naffected resource(s), the identity of which can be determined using\n'fmadm faulty'.\n"
1402#
1403# code: SUN4V-8002-Q2
1404# keys: fault.memory.memlink-uc
1405#
1406msgid "SUN4V-8002-Q2.type"
1407msgstr "Fault"
1408msgid "SUN4V-8002-Q2.severity"
1409msgstr "Critical"
1410msgid "SUN4V-8002-Q2.description"
1411msgstr "A problem was detected in the interconnect between a memory buffer\nand its memory controller.\n  Refer to %s for more information."
1412msgid "SUN4V-8002-Q2.response"
1413msgstr "The system crashed to prevent data corruption.  Memory in the affected\npartition may have been deconfigured.  (Consult system-specific\ndocumentation to find out how to determine if memory has been\ndeconfigured.)\n"
1414msgid "SUN4V-8002-Q2.impact"
1415msgstr "If memory has been deconfigured, system performance may be impacted. \n"
1416msgid "SUN4V-8002-Q2.action"
1417msgstr "Schedule a repair procedure to replace the appropriate part(s), the identity of which can be determined using 'fmadm faulty'.\n"
1418#
1419# code: SUN4V-8002-RA
1420# keys: defect.fw.generic-sparc.addr-oob
1421#
1422msgid "SUN4V-8002-RA.type"
1423msgstr "Fault"
1424msgid "SUN4V-8002-RA.severity"
1425msgstr "Critical"
1426msgid "SUN4V-8002-RA.description"
1427msgstr "An address-out-of-bounds error has occurred.\n  Refer to %s for more information."
1428msgid "SUN4V-8002-RA.response"
1429msgstr "No automated response.\n"
1430msgid "SUN4V-8002-RA.impact"
1431msgstr "The system may have taken a fatal reset.\n"
1432msgid "SUN4V-8002-RA.action"
1433msgstr "Call your service provider to determine if your system requires a firmware upgrade.\n"
1434#
1435# code: SUN4V-8002-SP
1436# keys: defect.fw.generic-sparc.erpt-gen
1437#
1438msgid "SUN4V-8002-SP.type"
1439msgstr "Fault"
1440msgid "SUN4V-8002-SP.severity"
1441msgstr "Major"
1442msgid "SUN4V-8002-SP.description"
1443msgstr "The error report generator has received input data that is inconsistent or\nimproperly formatted.\n  Refer to %s for more information."
1444msgid "SUN4V-8002-SP.response"
1445msgstr "No automated response.\n"
1446msgid "SUN4V-8002-SP.impact"
1447msgstr "This error does not affect system operation.  The error which\ncould not be reported may have more serious impact which cannot be determined.\n"
1448msgid "SUN4V-8002-SP.action"
1449msgstr "Call your service provider to determine if your system requires a firmware\nupgrade.  Please retain the error log file.\n"
1450#
1451# code: SUN4V-8002-T5
1452# keys: fault.cpu.generic-sparc.bootbus
1453#
1454msgid "SUN4V-8002-T5.type"
1455msgstr "Fault"
1456msgid "SUN4V-8002-T5.severity"
1457msgstr "Critical"
1458msgid "SUN4V-8002-T5.description"
1459msgstr "A system boot bus error has occurred.\n  Refer to %s for more information."
1460msgid "SUN4V-8002-T5.response"
1461msgstr "No automated response.\n"
1462msgid "SUN4V-8002-T5.impact"
1463msgstr "The system's integrity is seriously compromised.  Processor chip(s)\nmay be unavailable.\n"
1464msgid "SUN4V-8002-T5.action"
1465msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using 'fmadm faulty'.\n"
1466