xref: /titanic_51/usr/src/cmd/fm/dicts/SUN4U.po (revision bdfc6d18da790deeec2e0eb09c625902defe2498)
1#
2# Copyright 2005 Sun Microsystems, Inc.  All rights reserved.
3# Use is subject to license terms.
4#
5# CDDL HEADER START
6#
7# The contents of this file are subject to the terms of the
8# Common Development and Distribution License, Version 1.0 only
9# (the "License").  You may not use this file except in compliance
10# with the License.
11#
12# You can obtain a copy of the license at usr/src/OPENSOLARIS.LICENSE
13# or http://www.opensolaris.org/os/licensing.
14# See the License for the specific language governing permissions
15# and limitations under the License.
16#
17# When distributing Covered Code, include this CDDL HEADER in each
18# file and include the License file at usr/src/OPENSOLARIS.LICENSE.
19# If applicable, add the following below this CDDL HEADER, with the
20# fields enclosed by brackets "[]" replaced with your own identifying
21# information: Portions Copyright [yyyy] [name of copyright owner]
22#
23# CDDL HEADER END
24#
25#ident	"%Z%%M%	%I%	%E% SMI"
26
27#
28# code: SUN4U-8000-1A
29# keys: fault.memory.page
30#
31msgid "SUN4U-8000-1A.type"
32msgstr "Fault"
33msgid "SUN4U-8000-1A.severity"
34msgstr "Minor"
35msgid "SUN4U-8000-1A.description"
36msgstr "The number of errors associated with this memory module continues to exceed acceptable levels.  Refer to %s for more information."
37msgid "SUN4U-8000-1A.response"
38msgstr "An attempt will be made to remove this memory page from service."
39msgid "SUN4U-8000-1A.impact"
40msgstr "The performance of the system may be minimally impacted as a result of removing the memory page from operation."
41msgid "SUN4U-8000-1A.action"
42msgstr "No repair action is recommended at this time."
43#
44# code: SUN4U-8000-2S
45# keys: fault.memory.dimm
46#
47msgid "SUN4U-8000-2S.type"
48msgstr "Fault"
49msgid "SUN4U-8000-2S.severity"
50msgstr "Minor"
51msgid "SUN4U-8000-2S.description"
52msgstr "The number of errors associated with this memory module has exceeded acceptable levels.  Refer to %s for more information."
53msgid "SUN4U-8000-2S.response"
54msgstr "Pages of memory associated with this memory module are being removed from service as errors are reported."
55msgid "SUN4U-8000-2S.impact"
56msgstr "Total system memory capacity will be reduced as pages are retired."
57msgid "SUN4U-8000-2S.action"
58msgstr "Schedule a repair procedure to replace the affected memory module.  Use fmdump -v -u <EVENT_ID> to identify the module."
59#
60# code: SUN4U-8000-35
61# keys: fault.memory.bank
62#
63msgid "SUN4U-8000-35.type"
64msgstr "Fault"
65msgid "SUN4U-8000-35.severity"
66msgstr "Minor"
67msgid "SUN4U-8000-35.description"
68msgstr "The number of errors associated with this memory module has exceeded acceptable levels.  Refer to %s for more information."
69msgid "SUN4U-8000-35.response"
70msgstr "Pages of memory associated with this memory module are being removed from service as errors are reported."
71msgid "SUN4U-8000-35.impact"
72msgstr "Total system memory capacity will be reduced as pages are retired."
73msgid "SUN4U-8000-35.action"
74msgstr "Schedule a repair procedure to replace the affected memory module.  Use fmdump -v -u <EVENT_ID> to identify the module."
75#
76# code: SUN4U-8000-4Y
77# keys: fault.cpu.ultraSPARC-III.dcache
78#
79msgid "SUN4U-8000-4Y.type"
80msgstr "Fault"
81msgid "SUN4U-8000-4Y.severity"
82msgstr "Major"
83msgid "SUN4U-8000-4Y.description"
84msgstr "The number of errors associated with this CPU has exceeded acceptable levels.  Refer to %s for more information."
85msgid "SUN4U-8000-4Y.response"
86msgstr "An attempt will be made to remove the affected CPU from service."
87msgid "SUN4U-8000-4Y.impact"
88msgstr "Performance of this system may be affected."
89msgid "SUN4U-8000-4Y.action"
90msgstr "Schedule a repair procedure to replace the affected CPU.  Use fmdump -v -u <EVENT_ID> to identify the CPU."
91#
92# code: SUN4U-8000-53
93# keys: fault.cpu.ultraSPARC-III.icache
94#
95msgid "SUN4U-8000-53.type"
96msgstr "Fault"
97msgid "SUN4U-8000-53.severity"
98msgstr "Major"
99msgid "SUN4U-8000-53.description"
100msgstr "The number of errors associated with this CPU has exceeded acceptable levels.  Refer to %s for more information."
101msgid "SUN4U-8000-53.response"
102msgstr "An attempt will be made to remove the affected CPU from service."
103msgid "SUN4U-8000-53.impact"
104msgstr "Performance of this system may be affected."
105msgid "SUN4U-8000-53.action"
106msgstr "Schedule a repair procedure to replace the affected CPU.  Use fmdump -v -u <EVENT_ID> to identify the CPU."
107#
108# code: SUN4U-8000-6H
109# keys: fault.cpu.ultraSPARC-III.l2cachedata
110#
111msgid "SUN4U-8000-6H.type"
112msgstr "Fault"
113msgid "SUN4U-8000-6H.severity"
114msgstr "Major"
115msgid "SUN4U-8000-6H.description"
116msgstr "The number of errors associated with this CPU has exceeded acceptable levels.  Refer to %s for more information."
117msgid "SUN4U-8000-6H.response"
118msgstr "An attempt will be made to remove the affected CPU from service."
119msgid "SUN4U-8000-6H.impact"
120msgstr "Performance of this system may be affected."
121msgid "SUN4U-8000-6H.action"
122msgstr "Schedule a repair procedure to replace the affected CPU.  Use fmdump -v -u <EVENT_ID> to identify the CPU."
123#
124# code: SUN4U-8000-7D
125# keys: fault.cpu.ultraSPARC-III.l2cachetag
126#
127msgid "SUN4U-8000-7D.type"
128msgstr "Fault"
129msgid "SUN4U-8000-7D.severity"
130msgstr "Major"
131msgid "SUN4U-8000-7D.description"
132msgstr "The number of errors associated with this CPU has exceeded acceptable levels.  Refer to %s for more information."
133msgid "SUN4U-8000-7D.response"
134msgstr "An attempt will be made to remove the affected CPU from service."
135msgid "SUN4U-8000-7D.impact"
136msgstr "Performance of this system may be affected."
137msgid "SUN4U-8000-7D.action"
138msgstr "Schedule a repair procedure to replace the affected CPU.  Use fmdump -v -u <EVENT_ID> to identify the CPU."
139#
140# code: SUN4U-8000-84
141# keys: fault.cpu.ultraSPARC-IIIi.dcache
142#
143msgid "SUN4U-8000-84.type"
144msgstr "Fault"
145msgid "SUN4U-8000-84.severity"
146msgstr "Major"
147msgid "SUN4U-8000-84.description"
148msgstr "The number of errors associated with this CPU has exceeded acceptable levels.  Refer to %s for more information."
149msgid "SUN4U-8000-84.response"
150msgstr "An attempt will be made to remove the affected CPU from service."
151msgid "SUN4U-8000-84.impact"
152msgstr "Performance of this system may be affected."
153msgid "SUN4U-8000-84.action"
154msgstr "Schedule a repair procedure to replace the affected CPU.  Use fmdump -v -u <EVENT_ID> to identify the CPU."
155#
156# code: SUN4U-8000-9R
157# keys: fault.cpu.ultraSPARC-IIIi.icache
158#
159msgid "SUN4U-8000-9R.type"
160msgstr "Fault"
161msgid "SUN4U-8000-9R.severity"
162msgstr "Major"
163msgid "SUN4U-8000-9R.description"
164msgstr "The number of errors associated with this CPU has exceeded acceptable levels.  Refer to %s for more information."
165msgid "SUN4U-8000-9R.response"
166msgstr "An attempt will be made to remove the affected CPU from service."
167msgid "SUN4U-8000-9R.impact"
168msgstr "Performance of this system may be affected."
169msgid "SUN4U-8000-9R.action"
170msgstr "Schedule a repair procedure to replace the affected CPU.  Use fmdump -v -u <EVENT_ID> to identify the CPU."
171#
172# code: SUN4U-8000-AC
173# keys: fault.cpu.ultraSPARC-IIIi.l2cachedata
174#
175msgid "SUN4U-8000-AC.type"
176msgstr "Fault"
177msgid "SUN4U-8000-AC.severity"
178msgstr "Major"
179msgid "SUN4U-8000-AC.description"
180msgstr "The number of errors associated with this CPU has exceeded acceptable levels.  Refer to %s for more information."
181msgid "SUN4U-8000-AC.response"
182msgstr "An attempt will be made to remove the affected CPU from service."
183msgid "SUN4U-8000-AC.impact"
184msgstr "Performance of this system may be affected."
185msgid "SUN4U-8000-AC.action"
186msgstr "Schedule a repair procedure to replace the affected CPU.  Use fmdump -v -u <EVENT_ID> to identify the CPU."
187#
188# code: SUN4U-8000-CQ
189# keys: fault.cpu.ultraSPARC-IIIi.l2cachetag
190#
191msgid "SUN4U-8000-CQ.type"
192msgstr "Fault"
193msgid "SUN4U-8000-CQ.severity"
194msgstr "Major"
195msgid "SUN4U-8000-CQ.description"
196msgstr "The number of errors associated with this CPU has exceeded acceptable levels.  Refer to %s for more information."
197msgid "SUN4U-8000-CQ.response"
198msgstr "An attempt will be made to remove the affected CPU from service."
199msgid "SUN4U-8000-CQ.impact"
200msgstr "Performance of this system may be affected."
201msgid "SUN4U-8000-CQ.action"
202msgstr "Schedule a repair procedure to replace the affected CPU.  Use fmdump -v -u <EVENT_ID> to identify the CPU."
203#
204# code: SUN4U-8000-DE
205# keys: fault.cpu.ultraSPARC-IIIplus.dcache
206#
207msgid "SUN4U-8000-DE.type"
208msgstr "Fault"
209msgid "SUN4U-8000-DE.severity"
210msgstr "Major"
211msgid "SUN4U-8000-DE.description"
212msgstr "The number of errors associated with this CPU has exceeded acceptable levels.  Refer to %s for more information."
213msgid "SUN4U-8000-DE.response"
214msgstr "An attempt will be made to remove the affected CPU from service."
215msgid "SUN4U-8000-DE.impact"
216msgstr "Performance of this system may be affected."
217msgid "SUN4U-8000-DE.action"
218msgstr "Schedule a repair procedure to replace the affected CPU.  Use fmdump -v -u <EVENT_ID> to identify the CPU."
219#
220# code: SUN4U-8000-EJ
221# keys: fault.cpu.ultraSPARC-IIIplus.icache
222#
223msgid "SUN4U-8000-EJ.type"
224msgstr "Fault"
225msgid "SUN4U-8000-EJ.severity"
226msgstr "Major"
227msgid "SUN4U-8000-EJ.description"
228msgstr "The number of errors associated with this CPU has exceeded acceptable levels.  Refer to %s for more information."
229msgid "SUN4U-8000-EJ.response"
230msgstr "An attempt will be made to remove the affected CPU from service."
231msgid "SUN4U-8000-EJ.impact"
232msgstr "Performance of this system may be affected."
233msgid "SUN4U-8000-EJ.action"
234msgstr "Schedule a repair procedure to replace the affected CPU.  Use fmdump -v -u <EVENT_ID> to identify the CPU."
235#
236# code: SUN4U-8000-F2
237# keys: fault.cpu.ultraSPARC-IIIplus.l2cachedata
238#
239msgid "SUN4U-8000-F2.type"
240msgstr "Fault"
241msgid "SUN4U-8000-F2.severity"
242msgstr "Major"
243msgid "SUN4U-8000-F2.description"
244msgstr "The number of errors associated with this CPU has exceeded acceptable levels.  Refer to %s for more information."
245msgid "SUN4U-8000-F2.response"
246msgstr "An attempt will be made to remove the affected CPU from service."
247msgid "SUN4U-8000-F2.impact"
248msgstr "Performance of this system may be affected."
249msgid "SUN4U-8000-F2.action"
250msgstr "Schedule a repair procedure to replace the affected CPU.  Use fmdump -v -u <EVENT_ID> to identify the CPU."
251#
252# code: SUN4U-8000-GX
253# keys: fault.cpu.ultraSPARC-IIIplus.l2cachetag
254#
255msgid "SUN4U-8000-GX.type"
256msgstr "Fault"
257msgid "SUN4U-8000-GX.severity"
258msgstr "Major"
259msgid "SUN4U-8000-GX.description"
260msgstr "The number of errors associated with this CPU has exceeded acceptable levels.  Refer to %s for more information."
261msgid "SUN4U-8000-GX.response"
262msgstr "An attempt will be made to remove the affected CPU from service."
263msgid "SUN4U-8000-GX.impact"
264msgstr "Performance of this system may be affected."
265msgid "SUN4U-8000-GX.action"
266msgstr "Schedule a repair procedure to replace the affected CPU.  Use fmdump -v -u <EVENT_ID> to identify the CPU."
267#
268# code: SUN4U-8000-H5
269# keys: fault.cpu.ultraSPARC-IV.dcache
270#
271msgid "SUN4U-8000-H5.type"
272msgstr "Fault"
273msgid "SUN4U-8000-H5.severity"
274msgstr "Major"
275msgid "SUN4U-8000-H5.description"
276msgstr "The number of errors associated with this CPU has exceeded acceptable levels.  Refer to %s for more information."
277msgid "SUN4U-8000-H5.response"
278msgstr "An attempt will be made to remove the affected CPU from service."
279msgid "SUN4U-8000-H5.impact"
280msgstr "Performance of this system may be affected."
281msgid "SUN4U-8000-H5.action"
282msgstr "Schedule a repair procedure to replace the affected CPU.  Use fmdump -v -u <EVENT_ID> to identify the CPU."
283#
284# code: SUN4U-8000-JS
285# keys: fault.cpu.ultraSPARC-IV.icache
286#
287msgid "SUN4U-8000-JS.type"
288msgstr "Fault"
289msgid "SUN4U-8000-JS.severity"
290msgstr "Major"
291msgid "SUN4U-8000-JS.description"
292msgstr "The number of errors associated with this CPU has exceeded acceptable levels.  Refer to %s for more information."
293msgid "SUN4U-8000-JS.response"
294msgstr "An attempt will be made to remove the affected CPU from service."
295msgid "SUN4U-8000-JS.impact"
296msgstr "Performance of this system may be affected."
297msgid "SUN4U-8000-JS.action"
298msgstr "Schedule a repair procedure to replace the affected CPU.  Use fmdump -v -u <EVENT_ID> to identify the CPU."
299#
300# code: SUN4U-8000-KA
301# keys: fault.cpu.ultraSPARC-IV.l2cachedata
302#
303msgid "SUN4U-8000-KA.type"
304msgstr "Fault"
305msgid "SUN4U-8000-KA.severity"
306msgstr "Major"
307msgid "SUN4U-8000-KA.description"
308msgstr "The number of errors associated with this CPU has exceeded acceptable levels.  Refer to %s for more information."
309msgid "SUN4U-8000-KA.response"
310msgstr "An attempt will be made to remove the affected CPU from service."
311msgid "SUN4U-8000-KA.impact"
312msgstr "Performance of this system may be affected."
313msgid "SUN4U-8000-KA.action"
314msgstr "Schedule a repair procedure to replace the affected CPU.  Use fmdump -v -u <EVENT_ID> to identify the CPU."
315#
316# code: SUN4U-8000-LP
317# keys: fault.cpu.ultraSPARC-IV.l2cachetag
318#
319msgid "SUN4U-8000-LP.type"
320msgstr "Fault"
321msgid "SUN4U-8000-LP.severity"
322msgstr "Major"
323msgid "SUN4U-8000-LP.description"
324msgstr "The number of errors associated with this CPU has exceeded acceptable levels.  Refer to %s for more information."
325msgid "SUN4U-8000-LP.response"
326msgstr "An attempt will be made to remove the affected CPU from service."
327msgid "SUN4U-8000-LP.impact"
328msgstr "Performance of this system may be affected."
329msgid "SUN4U-8000-LP.action"
330msgstr "Schedule a repair procedure to replace the affected CPU.  Use fmdump -v -u <EVENT_ID> to identify the CPU."
331#
332# code: SUN4U-8000-MD
333# keys: fault.cpu.ultraSPARC-III.fpu
334#
335msgid "SUN4U-8000-MD.type"
336msgstr "Fault"
337msgid "SUN4U-8000-MD.severity"
338msgstr "Major"
339msgid "SUN4U-8000-MD.description"
340msgstr "A fault has been detected in the FPU of this CPU.  Refer to %s for more information."
341msgid "SUN4U-8000-MD.response"
342msgstr "An attempt will be made to remove the affected CPU from service."
343msgid "SUN4U-8000-MD.impact"
344msgstr "Performance of this system may be affected."
345msgid "SUN4U-8000-MD.action"
346msgstr "Schedule a repair procedure to replace the affected CPU.  Use fmdump -v -u <EVENT_ID> to identify the CPU."
347#
348# code: SUN4U-8000-NH
349# keys: fault.cpu.ultraSPARC-IIIi.fpu
350#
351msgid "SUN4U-8000-NH.type"
352msgstr "Fault"
353msgid "SUN4U-8000-NH.severity"
354msgstr "Major"
355msgid "SUN4U-8000-NH.description"
356msgstr "A fault has been detected in the FPU of this CPU.  Refer to %s for more information."
357msgid "SUN4U-8000-NH.response"
358msgstr "An attempt will be made to remove the affected CPU from service."
359msgid "SUN4U-8000-NH.impact"
360msgstr "Performance of this system may be affected."
361msgid "SUN4U-8000-NH.action"
362msgstr "Schedule a repair procedure to replace the affected CPU.  Use fmdump -v -u <EVENT_ID> to identify the CPU."
363#
364# code: SUN4U-8000-P3
365# keys: fault.cpu.ultraSPARC-IIIplus.fpu
366#
367msgid "SUN4U-8000-P3.type"
368msgstr "Fault"
369msgid "SUN4U-8000-P3.severity"
370msgstr "Major"
371msgid "SUN4U-8000-P3.description"
372msgstr "A fault has been detected in the FPU of this CPU.  Refer to %s for more information."
373msgid "SUN4U-8000-P3.response"
374msgstr "An attempt will be made to remove the affected CPU from service."
375msgid "SUN4U-8000-P3.impact"
376msgstr "Performance of this system may be affected."
377msgid "SUN4U-8000-P3.action"
378msgstr "Schedule a repair procedure to replace the affected CPU.  Use fmdump -v -u <EVENT_ID> to identify the CPU."
379#
380# code: SUN4U-8000-QY
381# keys: fault.cpu.ultraSPARC-IV.fpu
382#
383msgid "SUN4U-8000-QY.type"
384msgstr "Fault"
385msgid "SUN4U-8000-QY.severity"
386msgstr "Major"
387msgid "SUN4U-8000-QY.description"
388msgstr "A fault has been detected in the FPU of this CPU.  Refer to %s for more information."
389msgid "SUN4U-8000-QY.response"
390msgstr "An attempt will be made to remove the affected CPU from service."
391msgid "SUN4U-8000-QY.impact"
392msgstr "Performance of this system may be affected."
393msgid "SUN4U-8000-QY.action"
394msgstr "Schedule a repair procedure to replace the affected CPU.  Use fmdump -v -u <EVENT_ID> to identify the CPU."
395#
396# code: SUN4U-8000-RQ
397# keys: fault.cpu.ultraSPARC-IVplus.fpu
398#
399msgid "SUN4U-8000-RQ.type"
400msgstr "Fault"
401msgid "SUN4U-8000-RQ.severity"
402msgstr "Major"
403msgid "SUN4U-8000-RQ.description"
404msgstr "A fault has been detected in the FPU of this CPU.  Refer to %s for more information."
405msgid "SUN4U-8000-RQ.response"
406msgstr "An attempt will be made to remove the affected CPU from service."
407msgid "SUN4U-8000-RQ.impact"
408msgstr "Performance of this system may be affected."
409msgid "SUN4U-8000-RQ.action"
410msgstr "Schedule a repair procedure to replace the affected CPU.  Use fmdump -v -u <EVENT_ID> to identify the CPU."
411#
412# code: SUN4U-8000-SC
413# keys: fault.cpu.ultraSPARC-IVplus.dcache
414#
415msgid "SUN4U-8000-SC.type"
416msgstr "Fault"
417msgid "SUN4U-8000-SC.severity"
418msgstr "Major"
419msgid "SUN4U-8000-SC.description"
420msgstr "The number of errors associated with this CPU has exceeded acceptable levels.  Refer to %s for more information."
421msgid "SUN4U-8000-SC.response"
422msgstr "An attempt will be made to remove the affected CPU from service."
423msgid "SUN4U-8000-SC.impact"
424msgstr "Performance of this system may be affected."
425msgid "SUN4U-8000-SC.action"
426msgstr "Schedule a repair procedure to replace the affected CPU.  Use fmdump -v -u <EVENT_ID> to identify the CPU."
427#
428# code: SUN4U-8000-TR
429# keys: fault.cpu.ultraSPARC-IVplus.icache
430#
431msgid "SUN4U-8000-TR.type"
432msgstr "Fault"
433msgid "SUN4U-8000-TR.severity"
434msgstr "Major"
435msgid "SUN4U-8000-TR.description"
436msgstr "The number of errors associated with this CPU has exceeded acceptable levels.  Refer to %s for more information."
437msgid "SUN4U-8000-TR.response"
438msgstr "An attempt will be made to remove the affected CPU from service."
439msgid "SUN4U-8000-TR.impact"
440msgstr "Performance of this system may be affected."
441msgid "SUN4U-8000-TR.action"
442msgstr "Schedule a repair procedure to replace the affected CPU.  Use fmdump -v -u <EVENT_ID> to identify the CPU."
443#
444# code: SUN4U-8000-U4
445# keys: fault.cpu.ultraSPARC-IVplus.pcache
446#
447msgid "SUN4U-8000-U4.type"
448msgstr "Fault"
449msgid "SUN4U-8000-U4.severity"
450msgstr "Major"
451msgid "SUN4U-8000-U4.description"
452msgstr "The number of errors associated with this CPU has exceeded acceptable levels.  Refer to %s for more information."
453msgid "SUN4U-8000-U4.response"
454msgstr "An attempt will be made to remove the affected CPU from service."
455msgid "SUN4U-8000-U4.impact"
456msgstr "Performance of this system may be affected."
457msgid "SUN4U-8000-U4.action"
458msgstr "Schedule a repair procedure to replace the affected CPU.  Use fmdump -v -u <EVENT_ID> to identify the CPU."
459#
460# code: SUN4U-8000-VX
461# keys: fault.cpu.ultraSPARC-IVplus.dtlb
462#
463msgid "SUN4U-8000-VX.type"
464msgstr "Fault"
465msgid "SUN4U-8000-VX.severity"
466msgstr "Major"
467msgid "SUN4U-8000-VX.description"
468msgstr "The number of errors associated with this CPU has exceeded acceptable levels.  Refer to %s for more information."
469msgid "SUN4U-8000-VX.response"
470msgstr "An attempt will be made to remove the affected CPU from service."
471msgid "SUN4U-8000-VX.impact"
472msgstr "Performance of this system may be affected."
473msgid "SUN4U-8000-VX.action"
474msgstr "Schedule a repair procedure to replace the affected CPU.  Use fmdump -v -u <EVENT_ID> to identify the CPU."
475#
476# code: SUN4U-8000-W2
477# keys: fault.cpu.ultraSPARC-IVplus.itlb
478#
479msgid "SUN4U-8000-W2.type"
480msgstr "Fault"
481msgid "SUN4U-8000-W2.severity"
482msgstr "Major"
483msgid "SUN4U-8000-W2.description"
484msgstr "The number of errors associated with this CPU has exceeded acceptable levels.  Refer to %s for more information."
485msgid "SUN4U-8000-W2.response"
486msgstr "An attempt will be made to remove the affected CPU from service."
487msgid "SUN4U-8000-W2.impact"
488msgstr "Performance of this system may be affected."
489msgid "SUN4U-8000-W2.action"
490msgstr "Schedule a repair procedure to replace the affected CPU.  Use fmdump -v -u <EVENT_ID> to identify the CPU."
491#
492# code: SUN4U-8000-XJ
493# keys: fault.cpu.ultraSPARC-IVplus.l2cachedata
494#
495msgid "SUN4U-8000-XJ.type"
496msgstr "Fault"
497msgid "SUN4U-8000-XJ.severity"
498msgstr "Major"
499msgid "SUN4U-8000-XJ.description"
500msgstr "The number of errors associated with this CPU has exceeded acceptable levels.  Refer to %s for more information."
501msgid "SUN4U-8000-XJ.response"
502msgstr "An attempt will be made to remove the affected CPU from service."
503msgid "SUN4U-8000-XJ.impact"
504msgstr "Performance of this system may be affected."
505msgid "SUN4U-8000-XJ.action"
506msgstr "Schedule a repair procedure to replace the affected CPU.  Use fmdump -v -u <EVENT_ID> to identify the CPU."
507#
508# code: SUN4U-8000-YE
509# keys: fault.cpu.ultraSPARC-IVplus.l2cachetag
510#
511msgid "SUN4U-8000-YE.type"
512msgstr "Fault"
513msgid "SUN4U-8000-YE.severity"
514msgstr "Major"
515msgid "SUN4U-8000-YE.description"
516msgstr "The number of errors associated with this CPU has exceeded acceptable levels.  Refer to %s for more information."
517msgid "SUN4U-8000-YE.response"
518msgstr "An attempt will be made to remove the affected CPU from service."
519msgid "SUN4U-8000-YE.impact"
520msgstr "Performance of this system may be affected."
521msgid "SUN4U-8000-YE.action"
522msgstr "Schedule a repair procedure to replace the affected CPU.  Use fmdump -v -u <EVENT_ID> to identify the CPU."
523#
524# code: SUN4U-8001-0J
525# keys: fault.cpu.ultraSPARC-IVplus.l3cachedata
526#
527msgid "SUN4U-8001-0J.type"
528msgstr "Fault"
529msgid "SUN4U-8001-0J.severity"
530msgstr "Major"
531msgid "SUN4U-8001-0J.description"
532msgstr "The number of errors associated with this CPU has exceeded acceptable levels.  Refer to %s for more information."
533msgid "SUN4U-8001-0J.response"
534msgstr "An attempt will be made to remove the affected CPU from service."
535msgid "SUN4U-8001-0J.impact"
536msgstr "Performance of this system may be affected."
537msgid "SUN4U-8001-0J.action"
538msgstr "Schedule a repair procedure to replace the affected CPU.  Use fmdump -v -u <EVENT_ID> to identify the CPU."
539#
540# code: SUN4U-8001-1E
541# keys: fault.cpu.ultraSPARC-IVplus.l3cachetag
542#
543msgid "SUN4U-8001-1E.type"
544msgstr "Fault"
545msgid "SUN4U-8001-1E.severity"
546msgstr "Major"
547msgid "SUN4U-8001-1E.description"
548msgstr "The number of errors associated with this CPU has exceeded acceptable levels.  Refer to %s for more information."
549msgid "SUN4U-8001-1E.response"
550msgstr "An attempt will be made to remove the affected CPU from service."
551msgid "SUN4U-8001-1E.impact"
552msgstr "Performance of this system may be affected."
553msgid "SUN4U-8001-1E.action"
554msgstr "Schedule a repair procedure to replace the affected CPU.  Use fmdump -v -u <EVENT_ID> to identify the CPU."
555#
556# code: SUN4U-8001-2X
557# keys: defect.ultraSPARC-II.memory.nodiag
558#
559msgid "SUN4U-8001-2X.type"
560msgstr "Defect"
561msgid "SUN4U-8001-2X.severity"
562msgstr "Minor"
563msgid "SUN4U-8001-2X.description"
564msgstr "The Solaris Fault Manager received an event from the IO subsystem for which automated diagnosis software is currently unavailable. Refer to %s for more information"
565msgid "SUN4U-8001-2X.response"
566msgstr "The error information has been saved for examination by Sun."
567msgid "SUN4U-8001-2X.impact"
568msgstr "The error log will need to be manually examined using fmdump(1M) in order to determine if any human response is required."
569msgid "SUN4U-8001-2X.action"
570msgstr "Use fmdump -ev -u <EVENT-ID> to view and record the undiagnosed errors."
571#
572# code: SUN4U-8001-32
573# keys: fault.memory.datapath
574#
575msgid "SUN4U-8001-32.type"
576msgstr "Fault"
577msgid "SUN4U-8001-32.severity"
578msgstr "Major"
579msgid "SUN4U-8001-32.description"
580msgstr "Errors have been detected on multiple memory modules, suggesting that a problem exists somewhere else in the system.  Refer to %s for more information."
581msgid "SUN4U-8001-32.response"
582msgstr "Error reports from the affected components will be logged for examination by Sun."
583msgid "SUN4U-8001-32.impact"
584msgstr "System performance and stability may be affected."
585msgid "SUN4U-8001-32.action"
586msgstr "Contact your service provider for further diagnosis."
587#
588# code: SUN4U-8001-4R
589# keys: fault.io.datapath
590#
591msgid "SUN4U-8001-4R.type"
592msgstr "Fault"
593msgid "SUN4U-8001-4R.severity"
594msgstr "Critical"
595msgid "SUN4U-8001-4R.description"
596msgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
597msgid "SUN4U-8001-4R.response"
598msgstr "One or more device instances may be disabled"
599msgid "SUN4U-8001-4R.impact"
600msgstr "Loss of services provided by the device instances associated with this fault"
601msgid "SUN4U-8001-4R.action"
602msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
603#
604# code: SUN4U-8001-54
605# keys: defect.io.pci.driver fault.io.datapath
606#
607msgid "SUN4U-8001-54.type"
608msgstr "Fault"
609msgid "SUN4U-8001-54.severity"
610msgstr "Critical"
611msgid "SUN4U-8001-54.description"
612msgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
613msgid "SUN4U-8001-54.response"
614msgstr "One or more device instances may be disabled"
615msgid "SUN4U-8001-54.impact"
616msgstr "Loss of services provided by the device instances associated with this fault"
617msgid "SUN4U-8001-54.action"
618msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
619#
620# code: SUN4U-8001-6Q
621# keys: fault.io.datapath fault.io.pci.bus
622#
623msgid "SUN4U-8001-6Q.type"
624msgstr "Fault"
625msgid "SUN4U-8001-6Q.severity"
626msgstr "Critical"
627msgid "SUN4U-8001-6Q.description"
628msgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
629msgid "SUN4U-8001-6Q.response"
630msgstr "One or more device instances may be disabled"
631msgid "SUN4U-8001-6Q.impact"
632msgstr "Loss of services provided by the device instances associated with this fault"
633msgid "SUN4U-8001-6Q.action"
634msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
635#
636# code: SUN4U-8001-7C
637# keys: defect.io.pci.driver fault.io.datapath fault.io.pci.bus
638#
639msgid "SUN4U-8001-7C.type"
640msgstr "Fault"
641msgid "SUN4U-8001-7C.severity"
642msgstr "Critical"
643msgid "SUN4U-8001-7C.description"
644msgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
645msgid "SUN4U-8001-7C.response"
646msgstr "One or more device instances may be disabled"
647msgid "SUN4U-8001-7C.impact"
648msgstr "Loss of services provided by the device instances associated with this fault"
649msgid "SUN4U-8001-7C.action"
650msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
651#
652# code: SUN4U-8001-83
653# keys: fault.io.datapath fault.io.pci.device
654#
655msgid "SUN4U-8001-83.type"
656msgstr "Fault"
657msgid "SUN4U-8001-83.severity"
658msgstr "Critical"
659msgid "SUN4U-8001-83.description"
660msgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
661msgid "SUN4U-8001-83.response"
662msgstr "One or more device instances may be disabled"
663msgid "SUN4U-8001-83.impact"
664msgstr "Loss of services provided by the device instances associated with this fault"
665msgid "SUN4U-8001-83.action"
666msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
667#
668# code: SUN4U-8001-9Y
669# keys: defect.io.pci.driver fault.io.datapath fault.io.pci.device
670#
671msgid "SUN4U-8001-9Y.type"
672msgstr "Fault"
673msgid "SUN4U-8001-9Y.severity"
674msgstr "Critical"
675msgid "SUN4U-8001-9Y.description"
676msgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
677msgid "SUN4U-8001-9Y.response"
678msgstr "One or more device instances may be disabled"
679msgid "SUN4U-8001-9Y.impact"
680msgstr "Loss of services provided by the device instances associated with this fault"
681msgid "SUN4U-8001-9Y.action"
682msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
683#
684# code: SUN4U-8001-AD
685# keys: fault.io.datapath fault.io.pci.bus fault.io.pci.device
686#
687msgid "SUN4U-8001-AD.type"
688msgstr "Fault"
689msgid "SUN4U-8001-AD.severity"
690msgstr "Critical"
691msgid "SUN4U-8001-AD.description"
692msgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
693msgid "SUN4U-8001-AD.response"
694msgstr "One or more device instances may be disabled"
695msgid "SUN4U-8001-AD.impact"
696msgstr "Loss of services provided by the device instances associated with this fault"
697msgid "SUN4U-8001-AD.action"
698msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
699#
700# code: SUN4U-8001-CH
701# keys: defect.io.pci.driver fault.io.datapath fault.io.pci.bus fault.io.pci.device
702#
703msgid "SUN4U-8001-CH.type"
704msgstr "Fault"
705msgid "SUN4U-8001-CH.severity"
706msgstr "Critical"
707msgid "SUN4U-8001-CH.description"
708msgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
709msgid "SUN4U-8001-CH.response"
710msgstr "One or more device instances may be disabled"
711msgid "SUN4U-8001-CH.impact"
712msgstr "Loss of services provided by the device instances associated with this fault"
713msgid "SUN4U-8001-CH.action"
714msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
715#
716# code: SUN4U-8001-DA
717# keys: fault.io.hbus
718#
719msgid "SUN4U-8001-DA.type"
720msgstr "Fault"
721msgid "SUN4U-8001-DA.severity"
722msgstr "Critical"
723msgid "SUN4U-8001-DA.description"
724msgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
725msgid "SUN4U-8001-DA.response"
726msgstr "One or more device instances may be disabled"
727msgid "SUN4U-8001-DA.impact"
728msgstr "Loss of services provided by the device instances associated with this fault"
729msgid "SUN4U-8001-DA.action"
730msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
731#
732# code: SUN4U-8001-EP
733# keys: defect.io.pci.driver fault.io.hbus
734#
735msgid "SUN4U-8001-EP.type"
736msgstr "Fault"
737msgid "SUN4U-8001-EP.severity"
738msgstr "Critical"
739msgid "SUN4U-8001-EP.description"
740msgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
741msgid "SUN4U-8001-EP.response"
742msgstr "One or more device instances may be disabled"
743msgid "SUN4U-8001-EP.impact"
744msgstr "Loss of services provided by the device instances associated with this fault"
745msgid "SUN4U-8001-EP.action"
746msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
747#
748# code: SUN4U-8001-F5
749# keys: fault.io.hbus fault.io.pci.bus
750#
751msgid "SUN4U-8001-F5.type"
752msgstr "Fault"
753msgid "SUN4U-8001-F5.severity"
754msgstr "Critical"
755msgid "SUN4U-8001-F5.description"
756msgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
757msgid "SUN4U-8001-F5.response"
758msgstr "One or more device instances may be disabled"
759msgid "SUN4U-8001-F5.impact"
760msgstr "Loss of services provided by the device instances associated with this fault"
761msgid "SUN4U-8001-F5.action"
762msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
763#
764# code: SUN4U-8001-GS
765# keys: defect.io.pci.driver fault.io.hbus fault.io.pci.bus
766#
767msgid "SUN4U-8001-GS.type"
768msgstr "Fault"
769msgid "SUN4U-8001-GS.severity"
770msgstr "Critical"
771msgid "SUN4U-8001-GS.description"
772msgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
773msgid "SUN4U-8001-GS.response"
774msgstr "One or more device instances may be disabled"
775msgid "SUN4U-8001-GS.impact"
776msgstr "Loss of services provided by the device instances associated with this fault"
777msgid "SUN4U-8001-GS.action"
778msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
779#
780# code: SUN4U-8001-H2
781# keys: fault.io.hbus fault.io.pci.device
782#
783msgid "SUN4U-8001-H2.type"
784msgstr "Fault"
785msgid "SUN4U-8001-H2.severity"
786msgstr "Critical"
787msgid "SUN4U-8001-H2.description"
788msgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
789msgid "SUN4U-8001-H2.response"
790msgstr "One or more device instances may be disabled"
791msgid "SUN4U-8001-H2.impact"
792msgstr "Loss of services provided by the device instances associated with this fault"
793msgid "SUN4U-8001-H2.action"
794msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
795#
796# code: SUN4U-8001-JX
797# keys: defect.io.pci.driver fault.io.hbus fault.io.pci.device
798#
799msgid "SUN4U-8001-JX.type"
800msgstr "Fault"
801msgid "SUN4U-8001-JX.severity"
802msgstr "Critical"
803msgid "SUN4U-8001-JX.description"
804msgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
805msgid "SUN4U-8001-JX.response"
806msgstr "One or more device instances may be disabled"
807msgid "SUN4U-8001-JX.impact"
808msgstr "Loss of services provided by the device instances associated with this fault"
809msgid "SUN4U-8001-JX.action"
810msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
811#
812# code: SUN4U-8001-KE
813# keys: fault.io.hbus fault.io.pci.bus fault.io.pci.device
814#
815msgid "SUN4U-8001-KE.type"
816msgstr "Fault"
817msgid "SUN4U-8001-KE.severity"
818msgstr "Critical"
819msgid "SUN4U-8001-KE.description"
820msgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
821msgid "SUN4U-8001-KE.response"
822msgstr "One or more device instances may be disabled"
823msgid "SUN4U-8001-KE.impact"
824msgstr "Loss of services provided by the device instances associated with this fault"
825msgid "SUN4U-8001-KE.action"
826msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
827#
828# code: SUN4U-8001-LJ
829# keys: defect.io.pci.driver fault.io.hbus fault.io.pci.bus fault.io.pci.device
830#
831msgid "SUN4U-8001-LJ.type"
832msgstr "Fault"
833msgid "SUN4U-8001-LJ.severity"
834msgstr "Critical"
835msgid "SUN4U-8001-LJ.description"
836msgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
837msgid "SUN4U-8001-LJ.response"
838msgstr "One or more device instances may be disabled"
839msgid "SUN4U-8001-LJ.impact"
840msgstr "Loss of services provided by the device instances associated with this fault"
841msgid "SUN4U-8001-LJ.action"
842msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
843#
844# code: SUN4U-8001-MC
845# keys: fault.io.datapath fault.io.hbus
846#
847msgid "SUN4U-8001-MC.type"
848msgstr "Fault"
849msgid "SUN4U-8001-MC.severity"
850msgstr "Critical"
851msgid "SUN4U-8001-MC.description"
852msgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
853msgid "SUN4U-8001-MC.response"
854msgstr "One or more device instances may be disabled"
855msgid "SUN4U-8001-MC.impact"
856msgstr "Loss of services provided by the device instances associated with this fault"
857msgid "SUN4U-8001-MC.action"
858msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
859#
860# code: SUN4U-8001-NQ
861# keys: defect.io.pci.driver fault.io.datapath fault.io.hbus
862#
863msgid "SUN4U-8001-NQ.type"
864msgstr "Fault"
865msgid "SUN4U-8001-NQ.severity"
866msgstr "Critical"
867msgid "SUN4U-8001-NQ.description"
868msgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
869msgid "SUN4U-8001-NQ.response"
870msgstr "One or more device instances may be disabled"
871msgid "SUN4U-8001-NQ.impact"
872msgstr "Loss of services provided by the device instances associated with this fault"
873msgid "SUN4U-8001-NQ.action"
874msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
875#
876# code: SUN4U-8001-P4
877# keys: fault.io.datapath fault.io.hbus fault.io.pci.bus
878#
879msgid "SUN4U-8001-P4.type"
880msgstr "Fault"
881msgid "SUN4U-8001-P4.severity"
882msgstr "Critical"
883msgid "SUN4U-8001-P4.description"
884msgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
885msgid "SUN4U-8001-P4.response"
886msgstr "One or more device instances may be disabled"
887msgid "SUN4U-8001-P4.impact"
888msgstr "Loss of services provided by the device instances associated with this fault"
889msgid "SUN4U-8001-P4.action"
890msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
891#
892# code: SUN4U-8001-QR
893# keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.pci.bus
894#
895msgid "SUN4U-8001-QR.type"
896msgstr "Fault"
897msgid "SUN4U-8001-QR.severity"
898msgstr "Critical"
899msgid "SUN4U-8001-QR.description"
900msgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
901msgid "SUN4U-8001-QR.response"
902msgstr "One or more device instances may be disabled"
903msgid "SUN4U-8001-QR.impact"
904msgstr "Loss of services provided by the device instances associated with this fault"
905msgid "SUN4U-8001-QR.action"
906msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
907#
908# code: SUN4U-8001-RH
909# keys: fault.io.datapath fault.io.hbus fault.io.pci.device
910#
911msgid "SUN4U-8001-RH.type"
912msgstr "Fault"
913msgid "SUN4U-8001-RH.severity"
914msgstr "Critical"
915msgid "SUN4U-8001-RH.description"
916msgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
917msgid "SUN4U-8001-RH.response"
918msgstr "One or more device instances may be disabled"
919msgid "SUN4U-8001-RH.impact"
920msgstr "Loss of services provided by the device instances associated with this fault"
921msgid "SUN4U-8001-RH.action"
922msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
923#
924# code: SUN4U-8001-SD
925# keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.pci.device
926#
927msgid "SUN4U-8001-SD.type"
928msgstr "Fault"
929msgid "SUN4U-8001-SD.severity"
930msgstr "Critical"
931msgid "SUN4U-8001-SD.description"
932msgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
933msgid "SUN4U-8001-SD.response"
934msgstr "One or more device instances may be disabled"
935msgid "SUN4U-8001-SD.impact"
936msgstr "Loss of services provided by the device instances associated with this fault"
937msgid "SUN4U-8001-SD.action"
938msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
939#
940# code: SUN4U-8001-TY
941# keys: fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.pci.device
942#
943msgid "SUN4U-8001-TY.type"
944msgstr "Fault"
945msgid "SUN4U-8001-TY.severity"
946msgstr "Critical"
947msgid "SUN4U-8001-TY.description"
948msgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
949msgid "SUN4U-8001-TY.response"
950msgstr "One or more device instances may be disabled"
951msgid "SUN4U-8001-TY.impact"
952msgstr "Loss of services provided by the device instances associated with this fault"
953msgid "SUN4U-8001-TY.action"
954msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
955#
956# code: SUN4U-8001-U3
957# keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.pci.device
958#
959msgid "SUN4U-8001-U3.type"
960msgstr "Fault"
961msgid "SUN4U-8001-U3.severity"
962msgstr "Critical"
963msgid "SUN4U-8001-U3.description"
964msgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
965msgid "SUN4U-8001-U3.response"
966msgstr "One or more device instances may be disabled"
967msgid "SUN4U-8001-U3.impact"
968msgstr "Loss of services provided by the device instances associated with this fault"
969msgid "SUN4U-8001-U3.action"
970msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
971#
972# code: SUN4U-8001-VS
973# keys: fault.io.schizo
974#
975msgid "SUN4U-8001-VS.type"
976msgstr "Fault"
977msgid "SUN4U-8001-VS.severity"
978msgstr "Critical"
979msgid "SUN4U-8001-VS.description"
980msgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
981msgid "SUN4U-8001-VS.response"
982msgstr "One or more device instances may be disabled"
983msgid "SUN4U-8001-VS.impact"
984msgstr "Loss of services provided by the device instances associated with this fault"
985msgid "SUN4U-8001-VS.action"
986msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
987#
988# code: SUN4U-8001-W5
989# keys: defect.io.pci.driver fault.io.schizo
990#
991msgid "SUN4U-8001-W5.type"
992msgstr "Fault"
993msgid "SUN4U-8001-W5.severity"
994msgstr "Critical"
995msgid "SUN4U-8001-W5.description"
996msgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
997msgid "SUN4U-8001-W5.response"
998msgstr "One or more device instances may be disabled"
999msgid "SUN4U-8001-W5.impact"
1000msgstr "Loss of services provided by the device instances associated with this fault"
1001msgid "SUN4U-8001-W5.action"
1002msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
1003#
1004# code: SUN4U-8001-XP
1005# keys: fault.io.pci.bus fault.io.schizo
1006#
1007msgid "SUN4U-8001-XP.type"
1008msgstr "Fault"
1009msgid "SUN4U-8001-XP.severity"
1010msgstr "Critical"
1011msgid "SUN4U-8001-XP.description"
1012msgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
1013msgid "SUN4U-8001-XP.response"
1014msgstr "One or more device instances may be disabled"
1015msgid "SUN4U-8001-XP.impact"
1016msgstr "Loss of services provided by the device instances associated with this fault"
1017msgid "SUN4U-8001-XP.action"
1018msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
1019#
1020# code: SUN4U-8001-YA
1021# keys: defect.io.pci.driver fault.io.pci.bus fault.io.schizo
1022#
1023msgid "SUN4U-8001-YA.type"
1024msgstr "Fault"
1025msgid "SUN4U-8001-YA.severity"
1026msgstr "Critical"
1027msgid "SUN4U-8001-YA.description"
1028msgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
1029msgid "SUN4U-8001-YA.response"
1030msgstr "One or more device instances may be disabled"
1031msgid "SUN4U-8001-YA.impact"
1032msgstr "Loss of services provided by the device instances associated with this fault"
1033msgid "SUN4U-8001-YA.action"
1034msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
1035#
1036# code: SUN4U-8002-0R
1037# keys: fault.io.pci.device fault.io.schizo
1038#
1039msgid "SUN4U-8002-0R.type"
1040msgstr "Fault"
1041msgid "SUN4U-8002-0R.severity"
1042msgstr "Critical"
1043msgid "SUN4U-8002-0R.description"
1044msgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
1045msgid "SUN4U-8002-0R.response"
1046msgstr "One or more device instances may be disabled"
1047msgid "SUN4U-8002-0R.impact"
1048msgstr "Loss of services provided by the device instances associated with this fault"
1049msgid "SUN4U-8002-0R.action"
1050msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
1051#
1052# code: SUN4U-8002-14
1053# keys: defect.io.pci.driver fault.io.pci.device fault.io.schizo
1054#
1055msgid "SUN4U-8002-14.type"
1056msgstr "Fault"
1057msgid "SUN4U-8002-14.severity"
1058msgstr "Critical"
1059msgid "SUN4U-8002-14.description"
1060msgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
1061msgid "SUN4U-8002-14.response"
1062msgstr "One or more device instances may be disabled"
1063msgid "SUN4U-8002-14.impact"
1064msgstr "Loss of services provided by the device instances associated with this fault"
1065msgid "SUN4U-8002-14.action"
1066msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
1067#
1068# code: SUN4U-8002-2Q
1069# keys: fault.io.pci.bus fault.io.pci.device fault.io.schizo
1070#
1071msgid "SUN4U-8002-2Q.type"
1072msgstr "Fault"
1073msgid "SUN4U-8002-2Q.severity"
1074msgstr "Critical"
1075msgid "SUN4U-8002-2Q.description"
1076msgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
1077msgid "SUN4U-8002-2Q.response"
1078msgstr "One or more device instances may be disabled"
1079msgid "SUN4U-8002-2Q.impact"
1080msgstr "Loss of services provided by the device instances associated with this fault"
1081msgid "SUN4U-8002-2Q.action"
1082msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
1083#
1084# code: SUN4U-8002-3C
1085# keys: defect.io.pci.driver fault.io.pci.bus fault.io.pci.device fault.io.schizo
1086#
1087msgid "SUN4U-8002-3C.type"
1088msgstr "Fault"
1089msgid "SUN4U-8002-3C.severity"
1090msgstr "Critical"
1091msgid "SUN4U-8002-3C.description"
1092msgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
1093msgid "SUN4U-8002-3C.response"
1094msgstr "One or more device instances may be disabled"
1095msgid "SUN4U-8002-3C.impact"
1096msgstr "Loss of services provided by the device instances associated with this fault"
1097msgid "SUN4U-8002-3C.action"
1098msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
1099#
1100# code: SUN4U-8002-4J
1101# keys: fault.io.datapath fault.io.schizo
1102#
1103msgid "SUN4U-8002-4J.type"
1104msgstr "Fault"
1105msgid "SUN4U-8002-4J.severity"
1106msgstr "Critical"
1107msgid "SUN4U-8002-4J.description"
1108msgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
1109msgid "SUN4U-8002-4J.response"
1110msgstr "One or more device instances may be disabled"
1111msgid "SUN4U-8002-4J.impact"
1112msgstr "Loss of services provided by the device instances associated with this fault"
1113msgid "SUN4U-8002-4J.action"
1114msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
1115#
1116# code: SUN4U-8002-5E
1117# keys: defect.io.pci.driver fault.io.datapath fault.io.schizo
1118#
1119msgid "SUN4U-8002-5E.type"
1120msgstr "Fault"
1121msgid "SUN4U-8002-5E.severity"
1122msgstr "Critical"
1123msgid "SUN4U-8002-5E.description"
1124msgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
1125msgid "SUN4U-8002-5E.response"
1126msgstr "One or more device instances may be disabled"
1127msgid "SUN4U-8002-5E.impact"
1128msgstr "Loss of services provided by the device instances associated with this fault"
1129msgid "SUN4U-8002-5E.action"
1130msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
1131#
1132# code: SUN4U-8002-6X
1133# keys: fault.io.datapath fault.io.pci.bus fault.io.schizo
1134#
1135msgid "SUN4U-8002-6X.type"
1136msgstr "Fault"
1137msgid "SUN4U-8002-6X.severity"
1138msgstr "Critical"
1139msgid "SUN4U-8002-6X.description"
1140msgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
1141msgid "SUN4U-8002-6X.response"
1142msgstr "One or more device instances may be disabled"
1143msgid "SUN4U-8002-6X.impact"
1144msgstr "Loss of services provided by the device instances associated with this fault"
1145msgid "SUN4U-8002-6X.action"
1146msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
1147#
1148# code: SUN4U-8002-72
1149# keys: defect.io.pci.driver fault.io.datapath fault.io.pci.bus fault.io.schizo
1150#
1151msgid "SUN4U-8002-72.type"
1152msgstr "Fault"
1153msgid "SUN4U-8002-72.severity"
1154msgstr "Critical"
1155msgid "SUN4U-8002-72.description"
1156msgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
1157msgid "SUN4U-8002-72.response"
1158msgstr "One or more device instances may be disabled"
1159msgid "SUN4U-8002-72.impact"
1160msgstr "Loss of services provided by the device instances associated with this fault"
1161msgid "SUN4U-8002-72.action"
1162msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
1163#
1164# code: SUN4U-8002-8A
1165# keys: fault.io.datapath fault.io.pci.device fault.io.schizo
1166#
1167msgid "SUN4U-8002-8A.type"
1168msgstr "Fault"
1169msgid "SUN4U-8002-8A.severity"
1170msgstr "Critical"
1171msgid "SUN4U-8002-8A.description"
1172msgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
1173msgid "SUN4U-8002-8A.response"
1174msgstr "One or more device instances may be disabled"
1175msgid "SUN4U-8002-8A.impact"
1176msgstr "Loss of services provided by the device instances associated with this fault"
1177msgid "SUN4U-8002-8A.action"
1178msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
1179#
1180# code: SUN4U-8002-9P
1181# keys: defect.io.pci.driver fault.io.datapath fault.io.pci.device fault.io.schizo
1182#
1183msgid "SUN4U-8002-9P.type"
1184msgstr "Fault"
1185msgid "SUN4U-8002-9P.severity"
1186msgstr "Critical"
1187msgid "SUN4U-8002-9P.description"
1188msgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
1189msgid "SUN4U-8002-9P.response"
1190msgstr "One or more device instances may be disabled"
1191msgid "SUN4U-8002-9P.impact"
1192msgstr "Loss of services provided by the device instances associated with this fault"
1193msgid "SUN4U-8002-9P.action"
1194msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
1195#
1196# code: SUN4U-8002-A5
1197# keys: fault.io.datapath fault.io.pci.bus fault.io.pci.device fault.io.schizo
1198#
1199msgid "SUN4U-8002-A5.type"
1200msgstr "Fault"
1201msgid "SUN4U-8002-A5.severity"
1202msgstr "Critical"
1203msgid "SUN4U-8002-A5.description"
1204msgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
1205msgid "SUN4U-8002-A5.response"
1206msgstr "One or more device instances may be disabled"
1207msgid "SUN4U-8002-A5.impact"
1208msgstr "Loss of services provided by the device instances associated with this fault"
1209msgid "SUN4U-8002-A5.action"
1210msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
1211#
1212# code: SUN4U-8002-CS
1213# keys: defect.io.pci.driver fault.io.datapath fault.io.pci.bus fault.io.pci.device fault.io.schizo
1214#
1215msgid "SUN4U-8002-CS.type"
1216msgstr "Fault"
1217msgid "SUN4U-8002-CS.severity"
1218msgstr "Critical"
1219msgid "SUN4U-8002-CS.description"
1220msgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
1221msgid "SUN4U-8002-CS.response"
1222msgstr "One or more device instances may be disabled"
1223msgid "SUN4U-8002-CS.impact"
1224msgstr "Loss of services provided by the device instances associated with this fault"
1225msgid "SUN4U-8002-CS.action"
1226msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
1227#
1228# code: SUN4U-8002-D3
1229# keys: fault.io.hbus fault.io.schizo
1230#
1231msgid "SUN4U-8002-D3.type"
1232msgstr "Fault"
1233msgid "SUN4U-8002-D3.severity"
1234msgstr "Critical"
1235msgid "SUN4U-8002-D3.description"
1236msgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
1237msgid "SUN4U-8002-D3.response"
1238msgstr "One or more device instances may be disabled"
1239msgid "SUN4U-8002-D3.impact"
1240msgstr "Loss of services provided by the device instances associated with this fault"
1241msgid "SUN4U-8002-D3.action"
1242msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
1243#
1244# code: SUN4U-8002-EY
1245# keys: defect.io.pci.driver fault.io.hbus fault.io.schizo
1246#
1247msgid "SUN4U-8002-EY.type"
1248msgstr "Fault"
1249msgid "SUN4U-8002-EY.severity"
1250msgstr "Critical"
1251msgid "SUN4U-8002-EY.description"
1252msgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
1253msgid "SUN4U-8002-EY.response"
1254msgstr "One or more device instances may be disabled"
1255msgid "SUN4U-8002-EY.impact"
1256msgstr "Loss of services provided by the device instances associated with this fault"
1257msgid "SUN4U-8002-EY.action"
1258msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
1259#
1260# code: SUN4U-8002-FD
1261# keys: fault.io.hbus fault.io.pci.bus fault.io.schizo
1262#
1263msgid "SUN4U-8002-FD.type"
1264msgstr "Fault"
1265msgid "SUN4U-8002-FD.severity"
1266msgstr "Critical"
1267msgid "SUN4U-8002-FD.description"
1268msgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
1269msgid "SUN4U-8002-FD.response"
1270msgstr "One or more device instances may be disabled"
1271msgid "SUN4U-8002-FD.impact"
1272msgstr "Loss of services provided by the device instances associated with this fault"
1273msgid "SUN4U-8002-FD.action"
1274msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
1275#
1276# code: SUN4U-8002-GH
1277# keys: defect.io.pci.driver fault.io.hbus fault.io.pci.bus fault.io.schizo
1278#
1279msgid "SUN4U-8002-GH.type"
1280msgstr "Fault"
1281msgid "SUN4U-8002-GH.severity"
1282msgstr "Critical"
1283msgid "SUN4U-8002-GH.description"
1284msgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
1285msgid "SUN4U-8002-GH.response"
1286msgstr "One or more device instances may be disabled"
1287msgid "SUN4U-8002-GH.impact"
1288msgstr "Loss of services provided by the device instances associated with this fault"
1289msgid "SUN4U-8002-GH.action"
1290msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
1291#
1292# code: SUN4U-8002-HC
1293# keys: fault.io.hbus fault.io.pci.device fault.io.schizo
1294#
1295msgid "SUN4U-8002-HC.type"
1296msgstr "Fault"
1297msgid "SUN4U-8002-HC.severity"
1298msgstr "Critical"
1299msgid "SUN4U-8002-HC.description"
1300msgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
1301msgid "SUN4U-8002-HC.response"
1302msgstr "One or more device instances may be disabled"
1303msgid "SUN4U-8002-HC.impact"
1304msgstr "Loss of services provided by the device instances associated with this fault"
1305msgid "SUN4U-8002-HC.action"
1306msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
1307#
1308# code: SUN4U-8002-JQ
1309# keys: defect.io.pci.driver fault.io.hbus fault.io.pci.device fault.io.schizo
1310#
1311msgid "SUN4U-8002-JQ.type"
1312msgstr "Fault"
1313msgid "SUN4U-8002-JQ.severity"
1314msgstr "Critical"
1315msgid "SUN4U-8002-JQ.description"
1316msgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
1317msgid "SUN4U-8002-JQ.response"
1318msgstr "One or more device instances may be disabled"
1319msgid "SUN4U-8002-JQ.impact"
1320msgstr "Loss of services provided by the device instances associated with this fault"
1321msgid "SUN4U-8002-JQ.action"
1322msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
1323#
1324# code: SUN4U-8002-K4
1325# keys: fault.io.hbus fault.io.pci.bus fault.io.pci.device fault.io.schizo
1326#
1327msgid "SUN4U-8002-K4.type"
1328msgstr "Fault"
1329msgid "SUN4U-8002-K4.severity"
1330msgstr "Critical"
1331msgid "SUN4U-8002-K4.description"
1332msgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
1333msgid "SUN4U-8002-K4.response"
1334msgstr "One or more device instances may be disabled"
1335msgid "SUN4U-8002-K4.impact"
1336msgstr "Loss of services provided by the device instances associated with this fault"
1337msgid "SUN4U-8002-K4.action"
1338msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
1339#
1340# code: SUN4U-8002-LR
1341# keys: defect.io.pci.driver fault.io.hbus fault.io.pci.bus fault.io.pci.device fault.io.schizo
1342#
1343msgid "SUN4U-8002-LR.type"
1344msgstr "Fault"
1345msgid "SUN4U-8002-LR.severity"
1346msgstr "Critical"
1347msgid "SUN4U-8002-LR.description"
1348msgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
1349msgid "SUN4U-8002-LR.response"
1350msgstr "One or more device instances may be disabled"
1351msgid "SUN4U-8002-LR.impact"
1352msgstr "Loss of services provided by the device instances associated with this fault"
1353msgid "SUN4U-8002-LR.action"
1354msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
1355#
1356# code: SUN4U-8002-M2
1357# keys: fault.io.datapath fault.io.hbus fault.io.schizo
1358#
1359msgid "SUN4U-8002-M2.type"
1360msgstr "Fault"
1361msgid "SUN4U-8002-M2.severity"
1362msgstr "Critical"
1363msgid "SUN4U-8002-M2.description"
1364msgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
1365msgid "SUN4U-8002-M2.response"
1366msgstr "One or more device instances may be disabled"
1367msgid "SUN4U-8002-M2.impact"
1368msgstr "Loss of services provided by the device instances associated with this fault"
1369msgid "SUN4U-8002-M2.action"
1370msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
1371#
1372# code: SUN4U-8002-NX
1373# keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.schizo
1374#
1375msgid "SUN4U-8002-NX.type"
1376msgstr "Fault"
1377msgid "SUN4U-8002-NX.severity"
1378msgstr "Critical"
1379msgid "SUN4U-8002-NX.description"
1380msgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
1381msgid "SUN4U-8002-NX.response"
1382msgstr "One or more device instances may be disabled"
1383msgid "SUN4U-8002-NX.impact"
1384msgstr "Loss of services provided by the device instances associated with this fault"
1385msgid "SUN4U-8002-NX.action"
1386msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
1387#
1388# code: SUN4U-8002-PE
1389# keys: fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.schizo
1390#
1391msgid "SUN4U-8002-PE.type"
1392msgstr "Fault"
1393msgid "SUN4U-8002-PE.severity"
1394msgstr "Critical"
1395msgid "SUN4U-8002-PE.description"
1396msgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
1397msgid "SUN4U-8002-PE.response"
1398msgstr "One or more device instances may be disabled"
1399msgid "SUN4U-8002-PE.impact"
1400msgstr "Loss of services provided by the device instances associated with this fault"
1401msgid "SUN4U-8002-PE.action"
1402msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
1403#
1404# code: SUN4U-8002-QJ
1405# keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.schizo
1406#
1407msgid "SUN4U-8002-QJ.type"
1408msgstr "Fault"
1409msgid "SUN4U-8002-QJ.severity"
1410msgstr "Critical"
1411msgid "SUN4U-8002-QJ.description"
1412msgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
1413msgid "SUN4U-8002-QJ.response"
1414msgstr "One or more device instances may be disabled"
1415msgid "SUN4U-8002-QJ.impact"
1416msgstr "Loss of services provided by the device instances associated with this fault"
1417msgid "SUN4U-8002-QJ.action"
1418msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
1419#
1420# code: SUN4U-8002-RS
1421# keys: fault.io.datapath fault.io.hbus fault.io.pci.device fault.io.schizo
1422#
1423msgid "SUN4U-8002-RS.type"
1424msgstr "Fault"
1425msgid "SUN4U-8002-RS.severity"
1426msgstr "Critical"
1427msgid "SUN4U-8002-RS.description"
1428msgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
1429msgid "SUN4U-8002-RS.response"
1430msgstr "One or more device instances may be disabled"
1431msgid "SUN4U-8002-RS.impact"
1432msgstr "Loss of services provided by the device instances associated with this fault"
1433msgid "SUN4U-8002-RS.action"
1434msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
1435#
1436# code: SUN4U-8002-S5
1437# keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.pci.device fault.io.schizo
1438#
1439msgid "SUN4U-8002-S5.type"
1440msgstr "Fault"
1441msgid "SUN4U-8002-S5.severity"
1442msgstr "Critical"
1443msgid "SUN4U-8002-S5.description"
1444msgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
1445msgid "SUN4U-8002-S5.response"
1446msgstr "One or more device instances may be disabled"
1447msgid "SUN4U-8002-S5.impact"
1448msgstr "Loss of services provided by the device instances associated with this fault"
1449msgid "SUN4U-8002-S5.action"
1450msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
1451#
1452# code: SUN4U-8002-TP
1453# keys: fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.pci.device fault.io.schizo
1454#
1455msgid "SUN4U-8002-TP.type"
1456msgstr "Fault"
1457msgid "SUN4U-8002-TP.severity"
1458msgstr "Critical"
1459msgid "SUN4U-8002-TP.description"
1460msgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
1461msgid "SUN4U-8002-TP.response"
1462msgstr "One or more device instances may be disabled"
1463msgid "SUN4U-8002-TP.impact"
1464msgstr "Loss of services provided by the device instances associated with this fault"
1465msgid "SUN4U-8002-TP.action"
1466msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
1467#
1468# code: SUN4U-8002-UA
1469# keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.pci.device fault.io.schizo
1470#
1471msgid "SUN4U-8002-UA.type"
1472msgstr "Fault"
1473msgid "SUN4U-8002-UA.severity"
1474msgstr "Critical"
1475msgid "SUN4U-8002-UA.description"
1476msgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
1477msgid "SUN4U-8002-UA.response"
1478msgstr "One or more device instances may be disabled"
1479msgid "SUN4U-8002-UA.impact"
1480msgstr "Loss of services provided by the device instances associated with this fault"
1481msgid "SUN4U-8002-UA.action"
1482msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
1483#
1484# code: SUN4U-8002-VH
1485# keys: fault.io.xmits
1486#
1487msgid "SUN4U-8002-VH.type"
1488msgstr "Fault"
1489msgid "SUN4U-8002-VH.severity"
1490msgstr "Critical"
1491msgid "SUN4U-8002-VH.description"
1492msgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
1493msgid "SUN4U-8002-VH.response"
1494msgstr "One or more device instances may be disabled"
1495msgid "SUN4U-8002-VH.impact"
1496msgstr "Loss of services provided by the device instances associated with this fault"
1497msgid "SUN4U-8002-VH.action"
1498msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
1499#
1500# code: SUN4U-8002-WD
1501# keys: defect.io.pci.driver fault.io.xmits
1502#
1503msgid "SUN4U-8002-WD.type"
1504msgstr "Fault"
1505msgid "SUN4U-8002-WD.severity"
1506msgstr "Critical"
1507msgid "SUN4U-8002-WD.description"
1508msgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
1509msgid "SUN4U-8002-WD.response"
1510msgstr "One or more device instances may be disabled"
1511msgid "SUN4U-8002-WD.impact"
1512msgstr "Loss of services provided by the device instances associated with this fault"
1513msgid "SUN4U-8002-WD.action"
1514msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
1515#
1516# code: SUN4U-8002-XY
1517# keys: fault.io.pci.bus fault.io.xmits
1518#
1519msgid "SUN4U-8002-XY.type"
1520msgstr "Fault"
1521msgid "SUN4U-8002-XY.severity"
1522msgstr "Critical"
1523msgid "SUN4U-8002-XY.description"
1524msgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
1525msgid "SUN4U-8002-XY.response"
1526msgstr "One or more device instances may be disabled"
1527msgid "SUN4U-8002-XY.impact"
1528msgstr "Loss of services provided by the device instances associated with this fault"
1529msgid "SUN4U-8002-XY.action"
1530msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
1531#
1532# code: SUN4U-8002-Y3
1533# keys: defect.io.pci.driver fault.io.pci.bus fault.io.xmits
1534#
1535msgid "SUN4U-8002-Y3.type"
1536msgstr "Fault"
1537msgid "SUN4U-8002-Y3.severity"
1538msgstr "Critical"
1539msgid "SUN4U-8002-Y3.description"
1540msgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
1541msgid "SUN4U-8002-Y3.response"
1542msgstr "One or more device instances may be disabled"
1543msgid "SUN4U-8002-Y3.impact"
1544msgstr "Loss of services provided by the device instances associated with this fault"
1545msgid "SUN4U-8002-Y3.action"
1546msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
1547#
1548# code: SUN4U-8003-0Y
1549# keys: fault.io.pci.device fault.io.xmits
1550#
1551msgid "SUN4U-8003-0Y.type"
1552msgstr "Fault"
1553msgid "SUN4U-8003-0Y.severity"
1554msgstr "Critical"
1555msgid "SUN4U-8003-0Y.description"
1556msgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
1557msgid "SUN4U-8003-0Y.response"
1558msgstr "One or more device instances may be disabled"
1559msgid "SUN4U-8003-0Y.impact"
1560msgstr "Loss of services provided by the device instances associated with this fault"
1561msgid "SUN4U-8003-0Y.action"
1562msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
1563#
1564# code: SUN4U-8003-13
1565# keys: defect.io.pci.driver fault.io.pci.device fault.io.xmits
1566#
1567msgid "SUN4U-8003-13.type"
1568msgstr "Fault"
1569msgid "SUN4U-8003-13.severity"
1570msgstr "Critical"
1571msgid "SUN4U-8003-13.description"
1572msgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
1573msgid "SUN4U-8003-13.response"
1574msgstr "One or more device instances may be disabled"
1575msgid "SUN4U-8003-13.impact"
1576msgstr "Loss of services provided by the device instances associated with this fault"
1577msgid "SUN4U-8003-13.action"
1578msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
1579#
1580# code: SUN4U-8003-2H
1581# keys: fault.io.pci.bus fault.io.pci.device fault.io.xmits
1582#
1583msgid "SUN4U-8003-2H.type"
1584msgstr "Fault"
1585msgid "SUN4U-8003-2H.severity"
1586msgstr "Critical"
1587msgid "SUN4U-8003-2H.description"
1588msgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
1589msgid "SUN4U-8003-2H.response"
1590msgstr "One or more device instances may be disabled"
1591msgid "SUN4U-8003-2H.impact"
1592msgstr "Loss of services provided by the device instances associated with this fault"
1593msgid "SUN4U-8003-2H.action"
1594msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
1595#
1596# code: SUN4U-8003-3D
1597# keys: defect.io.pci.driver fault.io.pci.bus fault.io.pci.device fault.io.xmits
1598#
1599msgid "SUN4U-8003-3D.type"
1600msgstr "Fault"
1601msgid "SUN4U-8003-3D.severity"
1602msgstr "Critical"
1603msgid "SUN4U-8003-3D.description"
1604msgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
1605msgid "SUN4U-8003-3D.response"
1606msgstr "One or more device instances may be disabled"
1607msgid "SUN4U-8003-3D.impact"
1608msgstr "Loss of services provided by the device instances associated with this fault"
1609msgid "SUN4U-8003-3D.action"
1610msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
1611#
1612# code: SUN4U-8003-4P
1613# keys: fault.io.datapath fault.io.xmits
1614#
1615msgid "SUN4U-8003-4P.type"
1616msgstr "Fault"
1617msgid "SUN4U-8003-4P.severity"
1618msgstr "Critical"
1619msgid "SUN4U-8003-4P.description"
1620msgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
1621msgid "SUN4U-8003-4P.response"
1622msgstr "One or more device instances may be disabled"
1623msgid "SUN4U-8003-4P.impact"
1624msgstr "Loss of services provided by the device instances associated with this fault"
1625msgid "SUN4U-8003-4P.action"
1626msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
1627#
1628# code: SUN4U-8003-5A
1629# keys: defect.io.pci.driver fault.io.datapath fault.io.xmits
1630#
1631msgid "SUN4U-8003-5A.type"
1632msgstr "Fault"
1633msgid "SUN4U-8003-5A.severity"
1634msgstr "Critical"
1635msgid "SUN4U-8003-5A.description"
1636msgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
1637msgid "SUN4U-8003-5A.response"
1638msgstr "One or more device instances may be disabled"
1639msgid "SUN4U-8003-5A.impact"
1640msgstr "Loss of services provided by the device instances associated with this fault"
1641msgid "SUN4U-8003-5A.action"
1642msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
1643#
1644# code: SUN4U-8003-6S
1645# keys: fault.io.datapath fault.io.pci.bus fault.io.xmits
1646#
1647msgid "SUN4U-8003-6S.type"
1648msgstr "Fault"
1649msgid "SUN4U-8003-6S.severity"
1650msgstr "Critical"
1651msgid "SUN4U-8003-6S.description"
1652msgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
1653msgid "SUN4U-8003-6S.response"
1654msgstr "One or more device instances may be disabled"
1655msgid "SUN4U-8003-6S.impact"
1656msgstr "Loss of services provided by the device instances associated with this fault"
1657msgid "SUN4U-8003-6S.action"
1658msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
1659#
1660# code: SUN4U-8003-75
1661# keys: defect.io.pci.driver fault.io.datapath fault.io.pci.bus fault.io.xmits
1662#
1663msgid "SUN4U-8003-75.type"
1664msgstr "Fault"
1665msgid "SUN4U-8003-75.severity"
1666msgstr "Critical"
1667msgid "SUN4U-8003-75.description"
1668msgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
1669msgid "SUN4U-8003-75.response"
1670msgstr "One or more device instances may be disabled"
1671msgid "SUN4U-8003-75.impact"
1672msgstr "Loss of services provided by the device instances associated with this fault"
1673msgid "SUN4U-8003-75.action"
1674msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
1675#
1676# code: SUN4U-8003-8E
1677# keys: fault.io.datapath fault.io.pci.device fault.io.xmits
1678#
1679msgid "SUN4U-8003-8E.type"
1680msgstr "Fault"
1681msgid "SUN4U-8003-8E.severity"
1682msgstr "Critical"
1683msgid "SUN4U-8003-8E.description"
1684msgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
1685msgid "SUN4U-8003-8E.response"
1686msgstr "One or more device instances may be disabled"
1687msgid "SUN4U-8003-8E.impact"
1688msgstr "Loss of services provided by the device instances associated with this fault"
1689msgid "SUN4U-8003-8E.action"
1690msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
1691#
1692# code: SUN4U-8003-9J
1693# keys: defect.io.pci.driver fault.io.datapath fault.io.pci.device fault.io.xmits
1694#
1695msgid "SUN4U-8003-9J.type"
1696msgstr "Fault"
1697msgid "SUN4U-8003-9J.severity"
1698msgstr "Critical"
1699msgid "SUN4U-8003-9J.description"
1700msgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
1701msgid "SUN4U-8003-9J.response"
1702msgstr "One or more device instances may be disabled"
1703msgid "SUN4U-8003-9J.impact"
1704msgstr "Loss of services provided by the device instances associated with this fault"
1705msgid "SUN4U-8003-9J.action"
1706msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
1707#
1708# code: SUN4U-8003-A2
1709# keys: fault.io.datapath fault.io.pci.bus fault.io.pci.device fault.io.xmits
1710#
1711msgid "SUN4U-8003-A2.type"
1712msgstr "Fault"
1713msgid "SUN4U-8003-A2.severity"
1714msgstr "Critical"
1715msgid "SUN4U-8003-A2.description"
1716msgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
1717msgid "SUN4U-8003-A2.response"
1718msgstr "One or more device instances may be disabled"
1719msgid "SUN4U-8003-A2.impact"
1720msgstr "Loss of services provided by the device instances associated with this fault"
1721msgid "SUN4U-8003-A2.action"
1722msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
1723#
1724# code: SUN4U-8003-CX
1725# keys: defect.io.pci.driver fault.io.datapath fault.io.pci.bus fault.io.pci.device fault.io.xmits
1726#
1727msgid "SUN4U-8003-CX.type"
1728msgstr "Fault"
1729msgid "SUN4U-8003-CX.severity"
1730msgstr "Critical"
1731msgid "SUN4U-8003-CX.description"
1732msgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
1733msgid "SUN4U-8003-CX.response"
1734msgstr "One or more device instances may be disabled"
1735msgid "SUN4U-8003-CX.impact"
1736msgstr "Loss of services provided by the device instances associated with this fault"
1737msgid "SUN4U-8003-CX.action"
1738msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
1739#
1740# code: SUN4U-8003-D4
1741# keys: fault.io.hbus fault.io.xmits
1742#
1743msgid "SUN4U-8003-D4.type"
1744msgstr "Fault"
1745msgid "SUN4U-8003-D4.severity"
1746msgstr "Critical"
1747msgid "SUN4U-8003-D4.description"
1748msgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
1749msgid "SUN4U-8003-D4.response"
1750msgstr "One or more device instances may be disabled"
1751msgid "SUN4U-8003-D4.impact"
1752msgstr "Loss of services provided by the device instances associated with this fault"
1753msgid "SUN4U-8003-D4.action"
1754msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
1755#
1756# code: SUN4U-8003-ER
1757# keys: defect.io.pci.driver fault.io.hbus fault.io.xmits
1758#
1759msgid "SUN4U-8003-ER.type"
1760msgstr "Fault"
1761msgid "SUN4U-8003-ER.severity"
1762msgstr "Critical"
1763msgid "SUN4U-8003-ER.description"
1764msgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
1765msgid "SUN4U-8003-ER.response"
1766msgstr "One or more device instances may be disabled"
1767msgid "SUN4U-8003-ER.impact"
1768msgstr "Loss of services provided by the device instances associated with this fault"
1769msgid "SUN4U-8003-ER.action"
1770msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
1771#
1772# code: SUN4U-8003-FC
1773# keys: fault.io.hbus fault.io.pci.bus fault.io.xmits
1774#
1775msgid "SUN4U-8003-FC.type"
1776msgstr "Fault"
1777msgid "SUN4U-8003-FC.severity"
1778msgstr "Critical"
1779msgid "SUN4U-8003-FC.description"
1780msgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
1781msgid "SUN4U-8003-FC.response"
1782msgstr "One or more device instances may be disabled"
1783msgid "SUN4U-8003-FC.impact"
1784msgstr "Loss of services provided by the device instances associated with this fault"
1785msgid "SUN4U-8003-FC.action"
1786msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
1787#
1788# code: SUN4U-8003-GQ
1789# keys: defect.io.pci.driver fault.io.hbus fault.io.pci.bus fault.io.xmits
1790#
1791msgid "SUN4U-8003-GQ.type"
1792msgstr "Fault"
1793msgid "SUN4U-8003-GQ.severity"
1794msgstr "Critical"
1795msgid "SUN4U-8003-GQ.description"
1796msgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
1797msgid "SUN4U-8003-GQ.response"
1798msgstr "One or more device instances may be disabled"
1799msgid "SUN4U-8003-GQ.impact"
1800msgstr "Loss of services provided by the device instances associated with this fault"
1801msgid "SUN4U-8003-GQ.action"
1802msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
1803#
1804# code: SUN4U-8003-HD
1805# keys: fault.io.hbus fault.io.pci.device fault.io.xmits
1806#
1807msgid "SUN4U-8003-HD.type"
1808msgstr "Fault"
1809msgid "SUN4U-8003-HD.severity"
1810msgstr "Critical"
1811msgid "SUN4U-8003-HD.description"
1812msgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
1813msgid "SUN4U-8003-HD.response"
1814msgstr "One or more device instances may be disabled"
1815msgid "SUN4U-8003-HD.impact"
1816msgstr "Loss of services provided by the device instances associated with this fault"
1817msgid "SUN4U-8003-HD.action"
1818msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
1819#
1820# code: SUN4U-8003-JH
1821# keys: defect.io.pci.driver fault.io.hbus fault.io.pci.device fault.io.xmits
1822#
1823msgid "SUN4U-8003-JH.type"
1824msgstr "Fault"
1825msgid "SUN4U-8003-JH.severity"
1826msgstr "Critical"
1827msgid "SUN4U-8003-JH.description"
1828msgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
1829msgid "SUN4U-8003-JH.response"
1830msgstr "One or more device instances may be disabled"
1831msgid "SUN4U-8003-JH.impact"
1832msgstr "Loss of services provided by the device instances associated with this fault"
1833msgid "SUN4U-8003-JH.action"
1834msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
1835#
1836# code: SUN4U-8003-K3
1837# keys: fault.io.hbus fault.io.pci.bus fault.io.pci.device fault.io.xmits
1838#
1839msgid "SUN4U-8003-K3.type"
1840msgstr "Fault"
1841msgid "SUN4U-8003-K3.severity"
1842msgstr "Critical"
1843msgid "SUN4U-8003-K3.description"
1844msgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
1845msgid "SUN4U-8003-K3.response"
1846msgstr "One or more device instances may be disabled"
1847msgid "SUN4U-8003-K3.impact"
1848msgstr "Loss of services provided by the device instances associated with this fault"
1849msgid "SUN4U-8003-K3.action"
1850msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
1851#
1852# code: SUN4U-8003-LY
1853# keys: defect.io.pci.driver fault.io.hbus fault.io.pci.bus fault.io.pci.device fault.io.xmits
1854#
1855msgid "SUN4U-8003-LY.type"
1856msgstr "Fault"
1857msgid "SUN4U-8003-LY.severity"
1858msgstr "Critical"
1859msgid "SUN4U-8003-LY.description"
1860msgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
1861msgid "SUN4U-8003-LY.response"
1862msgstr "One or more device instances may be disabled"
1863msgid "SUN4U-8003-LY.impact"
1864msgstr "Loss of services provided by the device instances associated with this fault"
1865msgid "SUN4U-8003-LY.action"
1866msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
1867#
1868# code: SUN4U-8003-M5
1869# keys: fault.io.datapath fault.io.hbus fault.io.xmits
1870#
1871msgid "SUN4U-8003-M5.type"
1872msgstr "Fault"
1873msgid "SUN4U-8003-M5.severity"
1874msgstr "Critical"
1875msgid "SUN4U-8003-M5.description"
1876msgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
1877msgid "SUN4U-8003-M5.response"
1878msgstr "One or more device instances may be disabled"
1879msgid "SUN4U-8003-M5.impact"
1880msgstr "Loss of services provided by the device instances associated with this fault"
1881msgid "SUN4U-8003-M5.action"
1882msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
1883#
1884# code: SUN4U-8003-NS
1885# keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.xmits
1886#
1887msgid "SUN4U-8003-NS.type"
1888msgstr "Fault"
1889msgid "SUN4U-8003-NS.severity"
1890msgstr "Critical"
1891msgid "SUN4U-8003-NS.description"
1892msgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
1893msgid "SUN4U-8003-NS.response"
1894msgstr "One or more device instances may be disabled"
1895msgid "SUN4U-8003-NS.impact"
1896msgstr "Loss of services provided by the device instances associated with this fault"
1897msgid "SUN4U-8003-NS.action"
1898msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
1899#
1900# code: SUN4U-8003-PA
1901# keys: fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.xmits
1902#
1903msgid "SUN4U-8003-PA.type"
1904msgstr "Fault"
1905msgid "SUN4U-8003-PA.severity"
1906msgstr "Critical"
1907msgid "SUN4U-8003-PA.description"
1908msgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
1909msgid "SUN4U-8003-PA.response"
1910msgstr "One or more device instances may be disabled"
1911msgid "SUN4U-8003-PA.impact"
1912msgstr "Loss of services provided by the device instances associated with this fault"
1913msgid "SUN4U-8003-PA.action"
1914msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
1915#
1916# code: SUN4U-8003-QP
1917# keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.xmits
1918#
1919msgid "SUN4U-8003-QP.type"
1920msgstr "Fault"
1921msgid "SUN4U-8003-QP.severity"
1922msgstr "Critical"
1923msgid "SUN4U-8003-QP.description"
1924msgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
1925msgid "SUN4U-8003-QP.response"
1926msgstr "One or more device instances may be disabled"
1927msgid "SUN4U-8003-QP.impact"
1928msgstr "Loss of services provided by the device instances associated with this fault"
1929msgid "SUN4U-8003-QP.action"
1930msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
1931#
1932# code: SUN4U-8003-RX
1933# keys: fault.io.datapath fault.io.hbus fault.io.pci.device fault.io.xmits
1934#
1935msgid "SUN4U-8003-RX.type"
1936msgstr "Fault"
1937msgid "SUN4U-8003-RX.severity"
1938msgstr "Critical"
1939msgid "SUN4U-8003-RX.description"
1940msgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
1941msgid "SUN4U-8003-RX.response"
1942msgstr "One or more device instances may be disabled"
1943msgid "SUN4U-8003-RX.impact"
1944msgstr "Loss of services provided by the device instances associated with this fault"
1945msgid "SUN4U-8003-RX.action"
1946msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
1947#
1948# code: SUN4U-8003-S2
1949# keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.pci.device fault.io.xmits
1950#
1951msgid "SUN4U-8003-S2.type"
1952msgstr "Fault"
1953msgid "SUN4U-8003-S2.severity"
1954msgstr "Critical"
1955msgid "SUN4U-8003-S2.description"
1956msgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
1957msgid "SUN4U-8003-S2.response"
1958msgstr "One or more device instances may be disabled"
1959msgid "SUN4U-8003-S2.impact"
1960msgstr "Loss of services provided by the device instances associated with this fault"
1961msgid "SUN4U-8003-S2.action"
1962msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
1963#
1964# code: SUN4U-8003-TJ
1965# keys: fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.pci.device fault.io.xmits
1966#
1967msgid "SUN4U-8003-TJ.type"
1968msgstr "Fault"
1969msgid "SUN4U-8003-TJ.severity"
1970msgstr "Critical"
1971msgid "SUN4U-8003-TJ.description"
1972msgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
1973msgid "SUN4U-8003-TJ.response"
1974msgstr "One or more device instances may be disabled"
1975msgid "SUN4U-8003-TJ.impact"
1976msgstr "Loss of services provided by the device instances associated with this fault"
1977msgid "SUN4U-8003-TJ.action"
1978msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
1979#
1980# code: SUN4U-8003-UE
1981# keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.pci.device fault.io.xmits
1982#
1983msgid "SUN4U-8003-UE.type"
1984msgstr "Fault"
1985msgid "SUN4U-8003-UE.severity"
1986msgstr "Critical"
1987msgid "SUN4U-8003-UE.description"
1988msgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
1989msgid "SUN4U-8003-UE.response"
1990msgstr "One or more device instances may be disabled"
1991msgid "SUN4U-8003-UE.impact"
1992msgstr "Loss of services provided by the device instances associated with this fault"
1993msgid "SUN4U-8003-UE.action"
1994msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
1995#
1996# code: SUN4U-8003-VQ
1997# keys: fault.io.schizo fault.io.xmits
1998#
1999msgid "SUN4U-8003-VQ.type"
2000msgstr "Fault"
2001msgid "SUN4U-8003-VQ.severity"
2002msgstr "Critical"
2003msgid "SUN4U-8003-VQ.description"
2004msgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
2005msgid "SUN4U-8003-VQ.response"
2006msgstr "One or more device instances may be disabled"
2007msgid "SUN4U-8003-VQ.impact"
2008msgstr "Loss of services provided by the device instances associated with this fault"
2009msgid "SUN4U-8003-VQ.action"
2010msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
2011#
2012# code: SUN4U-8003-WC
2013# keys: defect.io.pci.driver fault.io.schizo fault.io.xmits
2014#
2015msgid "SUN4U-8003-WC.type"
2016msgstr "Fault"
2017msgid "SUN4U-8003-WC.severity"
2018msgstr "Critical"
2019msgid "SUN4U-8003-WC.description"
2020msgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
2021msgid "SUN4U-8003-WC.response"
2022msgstr "One or more device instances may be disabled"
2023msgid "SUN4U-8003-WC.impact"
2024msgstr "Loss of services provided by the device instances associated with this fault"
2025msgid "SUN4U-8003-WC.action"
2026msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
2027#
2028# code: SUN4U-8003-XR
2029# keys: fault.io.pci.bus fault.io.schizo fault.io.xmits
2030#
2031msgid "SUN4U-8003-XR.type"
2032msgstr "Fault"
2033msgid "SUN4U-8003-XR.severity"
2034msgstr "Critical"
2035msgid "SUN4U-8003-XR.description"
2036msgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
2037msgid "SUN4U-8003-XR.response"
2038msgstr "One or more device instances may be disabled"
2039msgid "SUN4U-8003-XR.impact"
2040msgstr "Loss of services provided by the device instances associated with this fault"
2041msgid "SUN4U-8003-XR.action"
2042msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
2043#
2044# code: SUN4U-8003-Y4
2045# keys: defect.io.pci.driver fault.io.pci.bus fault.io.schizo fault.io.xmits
2046#
2047msgid "SUN4U-8003-Y4.type"
2048msgstr "Fault"
2049msgid "SUN4U-8003-Y4.severity"
2050msgstr "Critical"
2051msgid "SUN4U-8003-Y4.description"
2052msgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
2053msgid "SUN4U-8003-Y4.response"
2054msgstr "One or more device instances may be disabled"
2055msgid "SUN4U-8003-Y4.impact"
2056msgstr "Loss of services provided by the device instances associated with this fault"
2057msgid "SUN4U-8003-Y4.action"
2058msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
2059#
2060# code: SUN4U-8004-0A
2061# keys: fault.io.pci.device fault.io.schizo fault.io.xmits
2062#
2063msgid "SUN4U-8004-0A.type"
2064msgstr "Fault"
2065msgid "SUN4U-8004-0A.severity"
2066msgstr "Critical"
2067msgid "SUN4U-8004-0A.description"
2068msgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
2069msgid "SUN4U-8004-0A.response"
2070msgstr "One or more device instances may be disabled"
2071msgid "SUN4U-8004-0A.impact"
2072msgstr "Loss of services provided by the device instances associated with this fault"
2073msgid "SUN4U-8004-0A.action"
2074msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
2075#
2076# code: SUN4U-8004-1P
2077# keys: defect.io.pci.driver fault.io.pci.device fault.io.schizo fault.io.xmits
2078#
2079msgid "SUN4U-8004-1P.type"
2080msgstr "Fault"
2081msgid "SUN4U-8004-1P.severity"
2082msgstr "Critical"
2083msgid "SUN4U-8004-1P.description"
2084msgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
2085msgid "SUN4U-8004-1P.response"
2086msgstr "One or more device instances may be disabled"
2087msgid "SUN4U-8004-1P.impact"
2088msgstr "Loss of services provided by the device instances associated with this fault"
2089msgid "SUN4U-8004-1P.action"
2090msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
2091#
2092# code: SUN4U-8004-25
2093# keys: fault.io.pci.bus fault.io.pci.device fault.io.schizo fault.io.xmits
2094#
2095msgid "SUN4U-8004-25.type"
2096msgstr "Fault"
2097msgid "SUN4U-8004-25.severity"
2098msgstr "Critical"
2099msgid "SUN4U-8004-25.description"
2100msgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
2101msgid "SUN4U-8004-25.response"
2102msgstr "One or more device instances may be disabled"
2103msgid "SUN4U-8004-25.impact"
2104msgstr "Loss of services provided by the device instances associated with this fault"
2105msgid "SUN4U-8004-25.action"
2106msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
2107#
2108# code: SUN4U-8004-3S
2109# keys: defect.io.pci.driver fault.io.pci.bus fault.io.pci.device fault.io.schizo fault.io.xmits
2110#
2111msgid "SUN4U-8004-3S.type"
2112msgstr "Fault"
2113msgid "SUN4U-8004-3S.severity"
2114msgstr "Critical"
2115msgid "SUN4U-8004-3S.description"
2116msgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
2117msgid "SUN4U-8004-3S.response"
2118msgstr "One or more device instances may be disabled"
2119msgid "SUN4U-8004-3S.impact"
2120msgstr "Loss of services provided by the device instances associated with this fault"
2121msgid "SUN4U-8004-3S.action"
2122msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
2123#
2124# code: SUN4U-8004-43
2125# keys: fault.io.datapath fault.io.schizo fault.io.xmits
2126#
2127msgid "SUN4U-8004-43.type"
2128msgstr "Fault"
2129msgid "SUN4U-8004-43.severity"
2130msgstr "Critical"
2131msgid "SUN4U-8004-43.description"
2132msgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
2133msgid "SUN4U-8004-43.response"
2134msgstr "One or more device instances may be disabled"
2135msgid "SUN4U-8004-43.impact"
2136msgstr "Loss of services provided by the device instances associated with this fault"
2137msgid "SUN4U-8004-43.action"
2138msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
2139#
2140# code: SUN4U-8004-5Y
2141# keys: defect.io.pci.driver fault.io.datapath fault.io.schizo fault.io.xmits
2142#
2143msgid "SUN4U-8004-5Y.type"
2144msgstr "Fault"
2145msgid "SUN4U-8004-5Y.severity"
2146msgstr "Critical"
2147msgid "SUN4U-8004-5Y.description"
2148msgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
2149msgid "SUN4U-8004-5Y.response"
2150msgstr "One or more device instances may be disabled"
2151msgid "SUN4U-8004-5Y.impact"
2152msgstr "Loss of services provided by the device instances associated with this fault"
2153msgid "SUN4U-8004-5Y.action"
2154msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
2155#
2156# code: SUN4U-8004-6D
2157# keys: fault.io.datapath fault.io.pci.bus fault.io.schizo fault.io.xmits
2158#
2159msgid "SUN4U-8004-6D.type"
2160msgstr "Fault"
2161msgid "SUN4U-8004-6D.severity"
2162msgstr "Critical"
2163msgid "SUN4U-8004-6D.description"
2164msgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
2165msgid "SUN4U-8004-6D.response"
2166msgstr "One or more device instances may be disabled"
2167msgid "SUN4U-8004-6D.impact"
2168msgstr "Loss of services provided by the device instances associated with this fault"
2169msgid "SUN4U-8004-6D.action"
2170msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
2171#
2172# code: SUN4U-8004-7H
2173# keys: defect.io.pci.driver fault.io.datapath fault.io.pci.bus fault.io.schizo fault.io.xmits
2174#
2175msgid "SUN4U-8004-7H.type"
2176msgstr "Fault"
2177msgid "SUN4U-8004-7H.severity"
2178msgstr "Critical"
2179msgid "SUN4U-8004-7H.description"
2180msgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
2181msgid "SUN4U-8004-7H.response"
2182msgstr "One or more device instances may be disabled"
2183msgid "SUN4U-8004-7H.impact"
2184msgstr "Loss of services provided by the device instances associated with this fault"
2185msgid "SUN4U-8004-7H.action"
2186msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
2187#
2188# code: SUN4U-8004-8R
2189# keys: fault.io.datapath fault.io.pci.device fault.io.schizo fault.io.xmits
2190#
2191msgid "SUN4U-8004-8R.type"
2192msgstr "Fault"
2193msgid "SUN4U-8004-8R.severity"
2194msgstr "Critical"
2195msgid "SUN4U-8004-8R.description"
2196msgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
2197msgid "SUN4U-8004-8R.response"
2198msgstr "One or more device instances may be disabled"
2199msgid "SUN4U-8004-8R.impact"
2200msgstr "Loss of services provided by the device instances associated with this fault"
2201msgid "SUN4U-8004-8R.action"
2202msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
2203#
2204# code: SUN4U-8004-94
2205# keys: defect.io.pci.driver fault.io.datapath fault.io.pci.device fault.io.schizo fault.io.xmits
2206#
2207msgid "SUN4U-8004-94.type"
2208msgstr "Fault"
2209msgid "SUN4U-8004-94.severity"
2210msgstr "Critical"
2211msgid "SUN4U-8004-94.description"
2212msgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
2213msgid "SUN4U-8004-94.response"
2214msgstr "One or more device instances may be disabled"
2215msgid "SUN4U-8004-94.impact"
2216msgstr "Loss of services provided by the device instances associated with this fault"
2217msgid "SUN4U-8004-94.action"
2218msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
2219#
2220# code: SUN4U-8004-AQ
2221# keys: fault.io.datapath fault.io.pci.bus fault.io.pci.device fault.io.schizo fault.io.xmits
2222#
2223msgid "SUN4U-8004-AQ.type"
2224msgstr "Fault"
2225msgid "SUN4U-8004-AQ.severity"
2226msgstr "Critical"
2227msgid "SUN4U-8004-AQ.description"
2228msgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
2229msgid "SUN4U-8004-AQ.response"
2230msgstr "One or more device instances may be disabled"
2231msgid "SUN4U-8004-AQ.impact"
2232msgstr "Loss of services provided by the device instances associated with this fault"
2233msgid "SUN4U-8004-AQ.action"
2234msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
2235#
2236# code: SUN4U-8004-CC
2237# keys: defect.io.pci.driver fault.io.datapath fault.io.pci.bus fault.io.pci.device fault.io.schizo fault.io.xmits
2238#
2239msgid "SUN4U-8004-CC.type"
2240msgstr "Fault"
2241msgid "SUN4U-8004-CC.severity"
2242msgstr "Critical"
2243msgid "SUN4U-8004-CC.description"
2244msgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
2245msgid "SUN4U-8004-CC.response"
2246msgstr "One or more device instances may be disabled"
2247msgid "SUN4U-8004-CC.impact"
2248msgstr "Loss of services provided by the device instances associated with this fault"
2249msgid "SUN4U-8004-CC.action"
2250msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
2251#
2252# code: SUN4U-8004-DJ
2253# keys: fault.io.hbus fault.io.schizo fault.io.xmits
2254#
2255msgid "SUN4U-8004-DJ.type"
2256msgstr "Fault"
2257msgid "SUN4U-8004-DJ.severity"
2258msgstr "Critical"
2259msgid "SUN4U-8004-DJ.description"
2260msgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
2261msgid "SUN4U-8004-DJ.response"
2262msgstr "One or more device instances may be disabled"
2263msgid "SUN4U-8004-DJ.impact"
2264msgstr "Loss of services provided by the device instances associated with this fault"
2265msgid "SUN4U-8004-DJ.action"
2266msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
2267#
2268# code: SUN4U-8004-EE
2269# keys: defect.io.pci.driver fault.io.hbus fault.io.schizo fault.io.xmits
2270#
2271msgid "SUN4U-8004-EE.type"
2272msgstr "Fault"
2273msgid "SUN4U-8004-EE.severity"
2274msgstr "Critical"
2275msgid "SUN4U-8004-EE.description"
2276msgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
2277msgid "SUN4U-8004-EE.response"
2278msgstr "One or more device instances may be disabled"
2279msgid "SUN4U-8004-EE.impact"
2280msgstr "Loss of services provided by the device instances associated with this fault"
2281msgid "SUN4U-8004-EE.action"
2282msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
2283#
2284# code: SUN4U-8004-FX
2285# keys: fault.io.hbus fault.io.pci.bus fault.io.schizo fault.io.xmits
2286#
2287msgid "SUN4U-8004-FX.type"
2288msgstr "Fault"
2289msgid "SUN4U-8004-FX.severity"
2290msgstr "Critical"
2291msgid "SUN4U-8004-FX.description"
2292msgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
2293msgid "SUN4U-8004-FX.response"
2294msgstr "One or more device instances may be disabled"
2295msgid "SUN4U-8004-FX.impact"
2296msgstr "Loss of services provided by the device instances associated with this fault"
2297msgid "SUN4U-8004-FX.action"
2298msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
2299#
2300# code: SUN4U-8004-G2
2301# keys: defect.io.pci.driver fault.io.hbus fault.io.pci.bus fault.io.schizo fault.io.xmits
2302#
2303msgid "SUN4U-8004-G2.type"
2304msgstr "Fault"
2305msgid "SUN4U-8004-G2.severity"
2306msgstr "Critical"
2307msgid "SUN4U-8004-G2.description"
2308msgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
2309msgid "SUN4U-8004-G2.response"
2310msgstr "One or more device instances may be disabled"
2311msgid "SUN4U-8004-G2.impact"
2312msgstr "Loss of services provided by the device instances associated with this fault"
2313msgid "SUN4U-8004-G2.action"
2314msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
2315#
2316# code: SUN4U-8004-HS
2317# keys: fault.io.hbus fault.io.pci.device fault.io.schizo fault.io.xmits
2318#
2319msgid "SUN4U-8004-HS.type"
2320msgstr "Fault"
2321msgid "SUN4U-8004-HS.severity"
2322msgstr "Critical"
2323msgid "SUN4U-8004-HS.description"
2324msgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
2325msgid "SUN4U-8004-HS.response"
2326msgstr "One or more device instances may be disabled"
2327msgid "SUN4U-8004-HS.impact"
2328msgstr "Loss of services provided by the device instances associated with this fault"
2329msgid "SUN4U-8004-HS.action"
2330msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
2331#
2332# code: SUN4U-8004-J5
2333# keys: defect.io.pci.driver fault.io.hbus fault.io.pci.device fault.io.schizo fault.io.xmits
2334#
2335msgid "SUN4U-8004-J5.type"
2336msgstr "Fault"
2337msgid "SUN4U-8004-J5.severity"
2338msgstr "Critical"
2339msgid "SUN4U-8004-J5.description"
2340msgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
2341msgid "SUN4U-8004-J5.response"
2342msgstr "One or more device instances may be disabled"
2343msgid "SUN4U-8004-J5.impact"
2344msgstr "Loss of services provided by the device instances associated with this fault"
2345msgid "SUN4U-8004-J5.action"
2346msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
2347#
2348# code: SUN4U-8004-KP
2349# keys: fault.io.hbus fault.io.pci.bus fault.io.pci.device fault.io.schizo fault.io.xmits
2350#
2351msgid "SUN4U-8004-KP.type"
2352msgstr "Fault"
2353msgid "SUN4U-8004-KP.severity"
2354msgstr "Critical"
2355msgid "SUN4U-8004-KP.description"
2356msgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
2357msgid "SUN4U-8004-KP.response"
2358msgstr "One or more device instances may be disabled"
2359msgid "SUN4U-8004-KP.impact"
2360msgstr "Loss of services provided by the device instances associated with this fault"
2361msgid "SUN4U-8004-KP.action"
2362msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
2363#
2364# code: SUN4U-8004-LA
2365# keys: defect.io.pci.driver fault.io.hbus fault.io.pci.bus fault.io.pci.device fault.io.schizo fault.io.xmits
2366#
2367msgid "SUN4U-8004-LA.type"
2368msgstr "Fault"
2369msgid "SUN4U-8004-LA.severity"
2370msgstr "Critical"
2371msgid "SUN4U-8004-LA.description"
2372msgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
2373msgid "SUN4U-8004-LA.response"
2374msgstr "One or more device instances may be disabled"
2375msgid "SUN4U-8004-LA.impact"
2376msgstr "Loss of services provided by the device instances associated with this fault"
2377msgid "SUN4U-8004-LA.action"
2378msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
2379#
2380# code: SUN4U-8004-MH
2381# keys: fault.io.datapath fault.io.hbus fault.io.schizo fault.io.xmits
2382#
2383msgid "SUN4U-8004-MH.type"
2384msgstr "Fault"
2385msgid "SUN4U-8004-MH.severity"
2386msgstr "Critical"
2387msgid "SUN4U-8004-MH.description"
2388msgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
2389msgid "SUN4U-8004-MH.response"
2390msgstr "One or more device instances may be disabled"
2391msgid "SUN4U-8004-MH.impact"
2392msgstr "Loss of services provided by the device instances associated with this fault"
2393msgid "SUN4U-8004-MH.action"
2394msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
2395#
2396# code: SUN4U-8004-ND
2397# keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.schizo fault.io.xmits
2398#
2399msgid "SUN4U-8004-ND.type"
2400msgstr "Fault"
2401msgid "SUN4U-8004-ND.severity"
2402msgstr "Critical"
2403msgid "SUN4U-8004-ND.description"
2404msgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
2405msgid "SUN4U-8004-ND.response"
2406msgstr "One or more device instances may be disabled"
2407msgid "SUN4U-8004-ND.impact"
2408msgstr "Loss of services provided by the device instances associated with this fault"
2409msgid "SUN4U-8004-ND.action"
2410msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
2411#
2412# code: SUN4U-8004-PY
2413# keys: fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.schizo fault.io.xmits
2414#
2415msgid "SUN4U-8004-PY.type"
2416msgstr "Fault"
2417msgid "SUN4U-8004-PY.severity"
2418msgstr "Critical"
2419msgid "SUN4U-8004-PY.description"
2420msgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
2421msgid "SUN4U-8004-PY.response"
2422msgstr "One or more device instances may be disabled"
2423msgid "SUN4U-8004-PY.impact"
2424msgstr "Loss of services provided by the device instances associated with this fault"
2425msgid "SUN4U-8004-PY.action"
2426msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
2427#
2428# code: SUN4U-8004-Q3
2429# keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.schizo fault.io.xmits
2430#
2431msgid "SUN4U-8004-Q3.type"
2432msgstr "Fault"
2433msgid "SUN4U-8004-Q3.severity"
2434msgstr "Critical"
2435msgid "SUN4U-8004-Q3.description"
2436msgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
2437msgid "SUN4U-8004-Q3.response"
2438msgstr "One or more device instances may be disabled"
2439msgid "SUN4U-8004-Q3.impact"
2440msgstr "Loss of services provided by the device instances associated with this fault"
2441msgid "SUN4U-8004-Q3.action"
2442msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
2443#
2444# code: SUN4U-8004-RC
2445# keys: fault.io.datapath fault.io.hbus fault.io.pci.device fault.io.schizo fault.io.xmits
2446#
2447msgid "SUN4U-8004-RC.type"
2448msgstr "Fault"
2449msgid "SUN4U-8004-RC.severity"
2450msgstr "Critical"
2451msgid "SUN4U-8004-RC.description"
2452msgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
2453msgid "SUN4U-8004-RC.response"
2454msgstr "One or more device instances may be disabled"
2455msgid "SUN4U-8004-RC.impact"
2456msgstr "Loss of services provided by the device instances associated with this fault"
2457msgid "SUN4U-8004-RC.action"
2458msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
2459#
2460# code: SUN4U-8004-SQ
2461# keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.pci.device fault.io.schizo fault.io.xmits
2462#
2463msgid "SUN4U-8004-SQ.type"
2464msgstr "Fault"
2465msgid "SUN4U-8004-SQ.severity"
2466msgstr "Critical"
2467msgid "SUN4U-8004-SQ.description"
2468msgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
2469msgid "SUN4U-8004-SQ.response"
2470msgstr "One or more device instances may be disabled"
2471msgid "SUN4U-8004-SQ.impact"
2472msgstr "Loss of services provided by the device instances associated with this fault"
2473msgid "SUN4U-8004-SQ.action"
2474msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
2475#
2476# code: SUN4U-8004-T4
2477# keys: fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.pci.device fault.io.schizo fault.io.xmits
2478#
2479msgid "SUN4U-8004-T4.type"
2480msgstr "Fault"
2481msgid "SUN4U-8004-T4.severity"
2482msgstr "Critical"
2483msgid "SUN4U-8004-T4.description"
2484msgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
2485msgid "SUN4U-8004-T4.response"
2486msgstr "One or more device instances may be disabled"
2487msgid "SUN4U-8004-T4.impact"
2488msgstr "Loss of services provided by the device instances associated with this fault"
2489msgid "SUN4U-8004-T4.action"
2490msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
2491#
2492# code: SUN4U-8004-UR
2493# keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.pci.device fault.io.schizo fault.io.xmits
2494#
2495msgid "SUN4U-8004-UR.type"
2496msgstr "Fault"
2497msgid "SUN4U-8004-UR.severity"
2498msgstr "Critical"
2499msgid "SUN4U-8004-UR.description"
2500msgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
2501msgid "SUN4U-8004-UR.response"
2502msgstr "One or more device instances may be disabled"
2503msgid "SUN4U-8004-UR.impact"
2504msgstr "Loss of services provided by the device instances associated with this fault"
2505msgid "SUN4U-8004-UR.action"
2506msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
2507#
2508# code: SUN4U-8004-V2
2509# keys: fault.io.psycho
2510#
2511msgid "SUN4U-8004-V2.type"
2512msgstr "Fault"
2513msgid "SUN4U-8004-V2.severity"
2514msgstr "Critical"
2515msgid "SUN4U-8004-V2.description"
2516msgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
2517msgid "SUN4U-8004-V2.response"
2518msgstr "One or more device instances may be disabled"
2519msgid "SUN4U-8004-V2.impact"
2520msgstr "Loss of services provided by the device instances associated with this fault"
2521msgid "SUN4U-8004-V2.action"
2522msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
2523#
2524# code: SUN4U-8004-WX
2525# keys: defect.io.pci.driver fault.io.psycho
2526#
2527msgid "SUN4U-8004-WX.type"
2528msgstr "Fault"
2529msgid "SUN4U-8004-WX.severity"
2530msgstr "Critical"
2531msgid "SUN4U-8004-WX.description"
2532msgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
2533msgid "SUN4U-8004-WX.response"
2534msgstr "One or more device instances may be disabled"
2535msgid "SUN4U-8004-WX.impact"
2536msgstr "Loss of services provided by the device instances associated with this fault"
2537msgid "SUN4U-8004-WX.action"
2538msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
2539#
2540# code: SUN4U-8004-XE
2541# keys: fault.io.datapath fault.io.psycho
2542#
2543msgid "SUN4U-8004-XE.type"
2544msgstr "Fault"
2545msgid "SUN4U-8004-XE.severity"
2546msgstr "Critical"
2547msgid "SUN4U-8004-XE.description"
2548msgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
2549msgid "SUN4U-8004-XE.response"
2550msgstr "One or more device instances may be disabled"
2551msgid "SUN4U-8004-XE.impact"
2552msgstr "Loss of services provided by the device instances associated with this fault"
2553msgid "SUN4U-8004-XE.action"
2554msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
2555#
2556# code: SUN4U-8004-YJ
2557# keys: defect.io.pci.driver fault.io.datapath fault.io.psycho
2558#
2559msgid "SUN4U-8004-YJ.type"
2560msgstr "Fault"
2561msgid "SUN4U-8004-YJ.severity"
2562msgstr "Critical"
2563msgid "SUN4U-8004-YJ.description"
2564msgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
2565msgid "SUN4U-8004-YJ.response"
2566msgstr "One or more device instances may be disabled"
2567msgid "SUN4U-8004-YJ.impact"
2568msgstr "Loss of services provided by the device instances associated with this fault"
2569msgid "SUN4U-8004-YJ.action"
2570msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
2571#
2572# code: SUN4U-8005-0E
2573# keys: fault.io.hbus fault.io.psycho
2574#
2575msgid "SUN4U-8005-0E.type"
2576msgstr "Fault"
2577msgid "SUN4U-8005-0E.severity"
2578msgstr "Critical"
2579msgid "SUN4U-8005-0E.description"
2580msgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
2581msgid "SUN4U-8005-0E.response"
2582msgstr "One or more device instances may be disabled"
2583msgid "SUN4U-8005-0E.impact"
2584msgstr "Loss of services provided by the device instances associated with this fault"
2585msgid "SUN4U-8005-0E.action"
2586msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
2587#
2588# code: SUN4U-8005-1J
2589# keys: defect.io.pci.driver fault.io.hbus fault.io.psycho
2590#
2591msgid "SUN4U-8005-1J.type"
2592msgstr "Fault"
2593msgid "SUN4U-8005-1J.severity"
2594msgstr "Critical"
2595msgid "SUN4U-8005-1J.description"
2596msgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
2597msgid "SUN4U-8005-1J.response"
2598msgstr "One or more device instances may be disabled"
2599msgid "SUN4U-8005-1J.impact"
2600msgstr "Loss of services provided by the device instances associated with this fault"
2601msgid "SUN4U-8005-1J.action"
2602msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
2603#
2604# code: SUN4U-8005-22
2605# keys: fault.io.datapath fault.io.hbus fault.io.psycho
2606#
2607msgid "SUN4U-8005-22.type"
2608msgstr "Fault"
2609msgid "SUN4U-8005-22.severity"
2610msgstr "Critical"
2611msgid "SUN4U-8005-22.description"
2612msgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
2613msgid "SUN4U-8005-22.response"
2614msgstr "One or more device instances may be disabled"
2615msgid "SUN4U-8005-22.impact"
2616msgstr "Loss of services provided by the device instances associated with this fault"
2617msgid "SUN4U-8005-22.action"
2618msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
2619#
2620# code: SUN4U-8005-3X
2621# keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.psycho
2622#
2623msgid "SUN4U-8005-3X.type"
2624msgstr "Fault"
2625msgid "SUN4U-8005-3X.severity"
2626msgstr "Critical"
2627msgid "SUN4U-8005-3X.description"
2628msgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
2629msgid "SUN4U-8005-3X.response"
2630msgstr "One or more device instances may be disabled"
2631msgid "SUN4U-8005-3X.impact"
2632msgstr "Loss of services provided by the device instances associated with this fault"
2633msgid "SUN4U-8005-3X.action"
2634msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
2635#
2636# code: SUN4U-8005-44
2637# keys: fault.io.pci.bus fault.io.psycho
2638#
2639msgid "SUN4U-8005-44.type"
2640msgstr "Fault"
2641msgid "SUN4U-8005-44.severity"
2642msgstr "Critical"
2643msgid "SUN4U-8005-44.description"
2644msgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
2645msgid "SUN4U-8005-44.response"
2646msgstr "One or more device instances may be disabled"
2647msgid "SUN4U-8005-44.impact"
2648msgstr "Loss of services provided by the device instances associated with this fault"
2649msgid "SUN4U-8005-44.action"
2650msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
2651#
2652# code: SUN4U-8005-5R
2653# keys: defect.io.pci.driver fault.io.pci.bus fault.io.psycho
2654#
2655msgid "SUN4U-8005-5R.type"
2656msgstr "Fault"
2657msgid "SUN4U-8005-5R.severity"
2658msgstr "Critical"
2659msgid "SUN4U-8005-5R.description"
2660msgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
2661msgid "SUN4U-8005-5R.response"
2662msgstr "One or more device instances may be disabled"
2663msgid "SUN4U-8005-5R.impact"
2664msgstr "Loss of services provided by the device instances associated with this fault"
2665msgid "SUN4U-8005-5R.action"
2666msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
2667#
2668# code: SUN4U-8005-6C
2669# keys: fault.io.datapath fault.io.pci.bus fault.io.psycho
2670#
2671msgid "SUN4U-8005-6C.type"
2672msgstr "Fault"
2673msgid "SUN4U-8005-6C.severity"
2674msgstr "Critical"
2675msgid "SUN4U-8005-6C.description"
2676msgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
2677msgid "SUN4U-8005-6C.response"
2678msgstr "One or more device instances may be disabled"
2679msgid "SUN4U-8005-6C.impact"
2680msgstr "Loss of services provided by the device instances associated with this fault"
2681msgid "SUN4U-8005-6C.action"
2682msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
2683#
2684# code: SUN4U-8005-7Q
2685# keys: defect.io.pci.driver fault.io.datapath fault.io.pci.bus fault.io.psycho
2686#
2687msgid "SUN4U-8005-7Q.type"
2688msgstr "Fault"
2689msgid "SUN4U-8005-7Q.severity"
2690msgstr "Critical"
2691msgid "SUN4U-8005-7Q.description"
2692msgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
2693msgid "SUN4U-8005-7Q.response"
2694msgstr "One or more device instances may be disabled"
2695msgid "SUN4U-8005-7Q.impact"
2696msgstr "Loss of services provided by the device instances associated with this fault"
2697msgid "SUN4U-8005-7Q.action"
2698msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
2699#
2700# code: SUN4U-8005-8Y
2701# keys: fault.io.hbus fault.io.pci.bus fault.io.psycho
2702#
2703msgid "SUN4U-8005-8Y.type"
2704msgstr "Fault"
2705msgid "SUN4U-8005-8Y.severity"
2706msgstr "Critical"
2707msgid "SUN4U-8005-8Y.description"
2708msgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
2709msgid "SUN4U-8005-8Y.response"
2710msgstr "One or more device instances may be disabled"
2711msgid "SUN4U-8005-8Y.impact"
2712msgstr "Loss of services provided by the device instances associated with this fault"
2713msgid "SUN4U-8005-8Y.action"
2714msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
2715#
2716# code: SUN4U-8005-93
2717# keys: defect.io.pci.driver fault.io.hbus fault.io.pci.bus fault.io.psycho
2718#
2719msgid "SUN4U-8005-93.type"
2720msgstr "Fault"
2721msgid "SUN4U-8005-93.severity"
2722msgstr "Critical"
2723msgid "SUN4U-8005-93.description"
2724msgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
2725msgid "SUN4U-8005-93.response"
2726msgstr "One or more device instances may be disabled"
2727msgid "SUN4U-8005-93.impact"
2728msgstr "Loss of services provided by the device instances associated with this fault"
2729msgid "SUN4U-8005-93.action"
2730msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
2731#
2732# code: SUN4U-8005-AH
2733# keys: fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.psycho
2734#
2735msgid "SUN4U-8005-AH.type"
2736msgstr "Fault"
2737msgid "SUN4U-8005-AH.severity"
2738msgstr "Critical"
2739msgid "SUN4U-8005-AH.description"
2740msgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
2741msgid "SUN4U-8005-AH.response"
2742msgstr "One or more device instances may be disabled"
2743msgid "SUN4U-8005-AH.impact"
2744msgstr "Loss of services provided by the device instances associated with this fault"
2745msgid "SUN4U-8005-AH.action"
2746msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
2747#
2748# code: SUN4U-8005-CD
2749# keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.psycho
2750#
2751msgid "SUN4U-8005-CD.type"
2752msgstr "Fault"
2753msgid "SUN4U-8005-CD.severity"
2754msgstr "Critical"
2755msgid "SUN4U-8005-CD.description"
2756msgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
2757msgid "SUN4U-8005-CD.response"
2758msgstr "One or more device instances may be disabled"
2759msgid "SUN4U-8005-CD.impact"
2760msgstr "Loss of services provided by the device instances associated with this fault"
2761msgid "SUN4U-8005-CD.action"
2762msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
2763#
2764# code: SUN4U-8005-DP
2765# keys: fault.io.pci.device fault.io.psycho
2766#
2767msgid "SUN4U-8005-DP.type"
2768msgstr "Fault"
2769msgid "SUN4U-8005-DP.severity"
2770msgstr "Critical"
2771msgid "SUN4U-8005-DP.description"
2772msgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
2773msgid "SUN4U-8005-DP.response"
2774msgstr "One or more device instances may be disabled"
2775msgid "SUN4U-8005-DP.impact"
2776msgstr "Loss of services provided by the device instances associated with this fault"
2777msgid "SUN4U-8005-DP.action"
2778msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
2779#
2780# code: SUN4U-8005-EA
2781# keys: defect.io.pci.driver fault.io.pci.device fault.io.psycho
2782#
2783msgid "SUN4U-8005-EA.type"
2784msgstr "Fault"
2785msgid "SUN4U-8005-EA.severity"
2786msgstr "Critical"
2787msgid "SUN4U-8005-EA.description"
2788msgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
2789msgid "SUN4U-8005-EA.response"
2790msgstr "One or more device instances may be disabled"
2791msgid "SUN4U-8005-EA.impact"
2792msgstr "Loss of services provided by the device instances associated with this fault"
2793msgid "SUN4U-8005-EA.action"
2794msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
2795#
2796# code: SUN4U-8005-FS
2797# keys: fault.io.datapath fault.io.pci.device fault.io.psycho
2798#
2799msgid "SUN4U-8005-FS.type"
2800msgstr "Fault"
2801msgid "SUN4U-8005-FS.severity"
2802msgstr "Critical"
2803msgid "SUN4U-8005-FS.description"
2804msgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
2805msgid "SUN4U-8005-FS.response"
2806msgstr "One or more device instances may be disabled"
2807msgid "SUN4U-8005-FS.impact"
2808msgstr "Loss of services provided by the device instances associated with this fault"
2809msgid "SUN4U-8005-FS.action"
2810msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
2811#
2812# code: SUN4U-8005-G5
2813# keys: defect.io.pci.driver fault.io.datapath fault.io.pci.device fault.io.psycho
2814#
2815msgid "SUN4U-8005-G5.type"
2816msgstr "Fault"
2817msgid "SUN4U-8005-G5.severity"
2818msgstr "Critical"
2819msgid "SUN4U-8005-G5.description"
2820msgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
2821msgid "SUN4U-8005-G5.response"
2822msgstr "One or more device instances may be disabled"
2823msgid "SUN4U-8005-G5.impact"
2824msgstr "Loss of services provided by the device instances associated with this fault"
2825msgid "SUN4U-8005-G5.action"
2826msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
2827#
2828# code: SUN4U-8005-HX
2829# keys: fault.io.hbus fault.io.pci.device fault.io.psycho
2830#
2831msgid "SUN4U-8005-HX.type"
2832msgstr "Fault"
2833msgid "SUN4U-8005-HX.severity"
2834msgstr "Critical"
2835msgid "SUN4U-8005-HX.description"
2836msgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
2837msgid "SUN4U-8005-HX.response"
2838msgstr "One or more device instances may be disabled"
2839msgid "SUN4U-8005-HX.impact"
2840msgstr "Loss of services provided by the device instances associated with this fault"
2841msgid "SUN4U-8005-HX.action"
2842msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
2843#
2844# code: SUN4U-8005-J2
2845# keys: defect.io.pci.driver fault.io.hbus fault.io.pci.device fault.io.psycho
2846#
2847msgid "SUN4U-8005-J2.type"
2848msgstr "Fault"
2849msgid "SUN4U-8005-J2.severity"
2850msgstr "Critical"
2851msgid "SUN4U-8005-J2.description"
2852msgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
2853msgid "SUN4U-8005-J2.response"
2854msgstr "One or more device instances may be disabled"
2855msgid "SUN4U-8005-J2.impact"
2856msgstr "Loss of services provided by the device instances associated with this fault"
2857msgid "SUN4U-8005-J2.action"
2858msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
2859#
2860# code: SUN4U-8005-KJ
2861# keys: fault.io.datapath fault.io.hbus fault.io.pci.device fault.io.psycho
2862#
2863msgid "SUN4U-8005-KJ.type"
2864msgstr "Fault"
2865msgid "SUN4U-8005-KJ.severity"
2866msgstr "Critical"
2867msgid "SUN4U-8005-KJ.description"
2868msgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
2869msgid "SUN4U-8005-KJ.response"
2870msgstr "One or more device instances may be disabled"
2871msgid "SUN4U-8005-KJ.impact"
2872msgstr "Loss of services provided by the device instances associated with this fault"
2873msgid "SUN4U-8005-KJ.action"
2874msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
2875#
2876# code: SUN4U-8005-LE
2877# keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.pci.device fault.io.psycho
2878#
2879msgid "SUN4U-8005-LE.type"
2880msgstr "Fault"
2881msgid "SUN4U-8005-LE.severity"
2882msgstr "Critical"
2883msgid "SUN4U-8005-LE.description"
2884msgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
2885msgid "SUN4U-8005-LE.response"
2886msgstr "One or more device instances may be disabled"
2887msgid "SUN4U-8005-LE.impact"
2888msgstr "Loss of services provided by the device instances associated with this fault"
2889msgid "SUN4U-8005-LE.action"
2890msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
2891#
2892# code: SUN4U-8005-MQ
2893# keys: fault.io.pci.bus fault.io.pci.device fault.io.psycho
2894#
2895msgid "SUN4U-8005-MQ.type"
2896msgstr "Fault"
2897msgid "SUN4U-8005-MQ.severity"
2898msgstr "Critical"
2899msgid "SUN4U-8005-MQ.description"
2900msgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
2901msgid "SUN4U-8005-MQ.response"
2902msgstr "One or more device instances may be disabled"
2903msgid "SUN4U-8005-MQ.impact"
2904msgstr "Loss of services provided by the device instances associated with this fault"
2905msgid "SUN4U-8005-MQ.action"
2906msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
2907#
2908# code: SUN4U-8005-NC
2909# keys: defect.io.pci.driver fault.io.pci.bus fault.io.pci.device fault.io.psycho
2910#
2911msgid "SUN4U-8005-NC.type"
2912msgstr "Fault"
2913msgid "SUN4U-8005-NC.severity"
2914msgstr "Critical"
2915msgid "SUN4U-8005-NC.description"
2916msgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
2917msgid "SUN4U-8005-NC.response"
2918msgstr "One or more device instances may be disabled"
2919msgid "SUN4U-8005-NC.impact"
2920msgstr "Loss of services provided by the device instances associated with this fault"
2921msgid "SUN4U-8005-NC.action"
2922msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
2923#
2924# code: SUN4U-8005-PR
2925# keys: fault.io.datapath fault.io.pci.bus fault.io.pci.device fault.io.psycho
2926#
2927msgid "SUN4U-8005-PR.type"
2928msgstr "Fault"
2929msgid "SUN4U-8005-PR.severity"
2930msgstr "Critical"
2931msgid "SUN4U-8005-PR.description"
2932msgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
2933msgid "SUN4U-8005-PR.response"
2934msgstr "One or more device instances may be disabled"
2935msgid "SUN4U-8005-PR.impact"
2936msgstr "Loss of services provided by the device instances associated with this fault"
2937msgid "SUN4U-8005-PR.action"
2938msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
2939#
2940# code: SUN4U-8005-Q4
2941# keys: defect.io.pci.driver fault.io.datapath fault.io.pci.bus fault.io.pci.device fault.io.psycho
2942#
2943msgid "SUN4U-8005-Q4.type"
2944msgstr "Fault"
2945msgid "SUN4U-8005-Q4.severity"
2946msgstr "Critical"
2947msgid "SUN4U-8005-Q4.description"
2948msgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
2949msgid "SUN4U-8005-Q4.response"
2950msgstr "One or more device instances may be disabled"
2951msgid "SUN4U-8005-Q4.impact"
2952msgstr "Loss of services provided by the device instances associated with this fault"
2953msgid "SUN4U-8005-Q4.action"
2954msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
2955#
2956# code: SUN4U-8005-RD
2957# keys: fault.io.hbus fault.io.pci.bus fault.io.pci.device fault.io.psycho
2958#
2959msgid "SUN4U-8005-RD.type"
2960msgstr "Fault"
2961msgid "SUN4U-8005-RD.severity"
2962msgstr "Critical"
2963msgid "SUN4U-8005-RD.description"
2964msgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
2965msgid "SUN4U-8005-RD.response"
2966msgstr "One or more device instances may be disabled"
2967msgid "SUN4U-8005-RD.impact"
2968msgstr "Loss of services provided by the device instances associated with this fault"
2969msgid "SUN4U-8005-RD.action"
2970msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
2971#
2972# code: SUN4U-8005-SH
2973# keys: defect.io.pci.driver fault.io.hbus fault.io.pci.bus fault.io.pci.device fault.io.psycho
2974#
2975msgid "SUN4U-8005-SH.type"
2976msgstr "Fault"
2977msgid "SUN4U-8005-SH.severity"
2978msgstr "Critical"
2979msgid "SUN4U-8005-SH.description"
2980msgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
2981msgid "SUN4U-8005-SH.response"
2982msgstr "One or more device instances may be disabled"
2983msgid "SUN4U-8005-SH.impact"
2984msgstr "Loss of services provided by the device instances associated with this fault"
2985msgid "SUN4U-8005-SH.action"
2986msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
2987#
2988# code: SUN4U-8005-T3
2989# keys: fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.pci.device fault.io.psycho
2990#
2991msgid "SUN4U-8005-T3.type"
2992msgstr "Fault"
2993msgid "SUN4U-8005-T3.severity"
2994msgstr "Critical"
2995msgid "SUN4U-8005-T3.description"
2996msgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
2997msgid "SUN4U-8005-T3.response"
2998msgstr "One or more device instances may be disabled"
2999msgid "SUN4U-8005-T3.impact"
3000msgstr "Loss of services provided by the device instances associated with this fault"
3001msgid "SUN4U-8005-T3.action"
3002msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
3003#
3004# code: SUN4U-8005-UY
3005# keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.pci.device fault.io.psycho
3006#
3007msgid "SUN4U-8005-UY.type"
3008msgstr "Fault"
3009msgid "SUN4U-8005-UY.severity"
3010msgstr "Critical"
3011msgid "SUN4U-8005-UY.description"
3012msgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
3013msgid "SUN4U-8005-UY.response"
3014msgstr "One or more device instances may be disabled"
3015msgid "SUN4U-8005-UY.impact"
3016msgstr "Loss of services provided by the device instances associated with this fault"
3017msgid "SUN4U-8005-UY.action"
3018msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
3019#
3020# code: SUN4U-8005-V5
3021# keys: fault.io.tomatillo
3022#
3023msgid "SUN4U-8005-V5.type"
3024msgstr "Fault"
3025msgid "SUN4U-8005-V5.severity"
3026msgstr "Critical"
3027msgid "SUN4U-8005-V5.description"
3028msgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
3029msgid "SUN4U-8005-V5.response"
3030msgstr "One or more device instances may be disabled"
3031msgid "SUN4U-8005-V5.impact"
3032msgstr "Loss of services provided by the device instances associated with this fault"
3033msgid "SUN4U-8005-V5.action"
3034msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
3035#
3036# code: SUN4U-8005-WS
3037# keys: defect.io.pci.driver fault.io.tomatillo
3038#
3039msgid "SUN4U-8005-WS.type"
3040msgstr "Fault"
3041msgid "SUN4U-8005-WS.severity"
3042msgstr "Critical"
3043msgid "SUN4U-8005-WS.description"
3044msgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
3045msgid "SUN4U-8005-WS.response"
3046msgstr "One or more device instances may be disabled"
3047msgid "SUN4U-8005-WS.impact"
3048msgstr "Loss of services provided by the device instances associated with this fault"
3049msgid "SUN4U-8005-WS.action"
3050msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
3051#
3052# code: SUN4U-8005-XA
3053# keys: fault.io.datapath fault.io.tomatillo
3054#
3055msgid "SUN4U-8005-XA.type"
3056msgstr "Fault"
3057msgid "SUN4U-8005-XA.severity"
3058msgstr "Critical"
3059msgid "SUN4U-8005-XA.description"
3060msgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
3061msgid "SUN4U-8005-XA.response"
3062msgstr "One or more device instances may be disabled"
3063msgid "SUN4U-8005-XA.impact"
3064msgstr "Loss of services provided by the device instances associated with this fault"
3065msgid "SUN4U-8005-XA.action"
3066msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
3067#
3068# code: SUN4U-8005-YP
3069# keys: defect.io.pci.driver fault.io.datapath fault.io.tomatillo
3070#
3071msgid "SUN4U-8005-YP.type"
3072msgstr "Fault"
3073msgid "SUN4U-8005-YP.severity"
3074msgstr "Critical"
3075msgid "SUN4U-8005-YP.description"
3076msgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
3077msgid "SUN4U-8005-YP.response"
3078msgstr "One or more device instances may be disabled"
3079msgid "SUN4U-8005-YP.impact"
3080msgstr "Loss of services provided by the device instances associated with this fault"
3081msgid "SUN4U-8005-YP.action"
3082msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
3083#
3084# code: SUN4U-8006-04
3085# keys: fault.io.hbus fault.io.tomatillo
3086#
3087msgid "SUN4U-8006-04.type"
3088msgstr "Fault"
3089msgid "SUN4U-8006-04.severity"
3090msgstr "Critical"
3091msgid "SUN4U-8006-04.description"
3092msgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
3093msgid "SUN4U-8006-04.response"
3094msgstr "One or more device instances may be disabled"
3095msgid "SUN4U-8006-04.impact"
3096msgstr "Loss of services provided by the device instances associated with this fault"
3097msgid "SUN4U-8006-04.action"
3098msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
3099#
3100# code: SUN4U-8006-1R
3101# keys: defect.io.pci.driver fault.io.hbus fault.io.tomatillo
3102#
3103msgid "SUN4U-8006-1R.type"
3104msgstr "Fault"
3105msgid "SUN4U-8006-1R.severity"
3106msgstr "Critical"
3107msgid "SUN4U-8006-1R.description"
3108msgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
3109msgid "SUN4U-8006-1R.response"
3110msgstr "One or more device instances may be disabled"
3111msgid "SUN4U-8006-1R.impact"
3112msgstr "Loss of services provided by the device instances associated with this fault"
3113msgid "SUN4U-8006-1R.action"
3114msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
3115#
3116# code: SUN4U-8006-2C
3117# keys: fault.io.datapath fault.io.hbus fault.io.tomatillo
3118#
3119msgid "SUN4U-8006-2C.type"
3120msgstr "Fault"
3121msgid "SUN4U-8006-2C.severity"
3122msgstr "Critical"
3123msgid "SUN4U-8006-2C.description"
3124msgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
3125msgid "SUN4U-8006-2C.response"
3126msgstr "One or more device instances may be disabled"
3127msgid "SUN4U-8006-2C.impact"
3128msgstr "Loss of services provided by the device instances associated with this fault"
3129msgid "SUN4U-8006-2C.action"
3130msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
3131#
3132# code: SUN4U-8006-3Q
3133# keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.tomatillo
3134#
3135msgid "SUN4U-8006-3Q.type"
3136msgstr "Fault"
3137msgid "SUN4U-8006-3Q.severity"
3138msgstr "Critical"
3139msgid "SUN4U-8006-3Q.description"
3140msgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
3141msgid "SUN4U-8006-3Q.response"
3142msgstr "One or more device instances may be disabled"
3143msgid "SUN4U-8006-3Q.impact"
3144msgstr "Loss of services provided by the device instances associated with this fault"
3145msgid "SUN4U-8006-3Q.action"
3146msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
3147#
3148# code: SUN4U-8006-4E
3149# keys: fault.io.pci.bus fault.io.tomatillo
3150#
3151msgid "SUN4U-8006-4E.type"
3152msgstr "Fault"
3153msgid "SUN4U-8006-4E.severity"
3154msgstr "Critical"
3155msgid "SUN4U-8006-4E.description"
3156msgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
3157msgid "SUN4U-8006-4E.response"
3158msgstr "One or more device instances may be disabled"
3159msgid "SUN4U-8006-4E.impact"
3160msgstr "Loss of services provided by the device instances associated with this fault"
3161msgid "SUN4U-8006-4E.action"
3162msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
3163#
3164# code: SUN4U-8006-5J
3165# keys: defect.io.pci.driver fault.io.pci.bus fault.io.tomatillo
3166#
3167msgid "SUN4U-8006-5J.type"
3168msgstr "Fault"
3169msgid "SUN4U-8006-5J.severity"
3170msgstr "Critical"
3171msgid "SUN4U-8006-5J.description"
3172msgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
3173msgid "SUN4U-8006-5J.response"
3174msgstr "One or more device instances may be disabled"
3175msgid "SUN4U-8006-5J.impact"
3176msgstr "Loss of services provided by the device instances associated with this fault"
3177msgid "SUN4U-8006-5J.action"
3178msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
3179#
3180# code: SUN4U-8006-62
3181# keys: fault.io.datapath fault.io.pci.bus fault.io.tomatillo
3182#
3183msgid "SUN4U-8006-62.type"
3184msgstr "Fault"
3185msgid "SUN4U-8006-62.severity"
3186msgstr "Critical"
3187msgid "SUN4U-8006-62.description"
3188msgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
3189msgid "SUN4U-8006-62.response"
3190msgstr "One or more device instances may be disabled"
3191msgid "SUN4U-8006-62.impact"
3192msgstr "Loss of services provided by the device instances associated with this fault"
3193msgid "SUN4U-8006-62.action"
3194msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
3195#
3196# code: SUN4U-8006-7X
3197# keys: defect.io.pci.driver fault.io.datapath fault.io.pci.bus fault.io.tomatillo
3198#
3199msgid "SUN4U-8006-7X.type"
3200msgstr "Fault"
3201msgid "SUN4U-8006-7X.severity"
3202msgstr "Critical"
3203msgid "SUN4U-8006-7X.description"
3204msgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
3205msgid "SUN4U-8006-7X.response"
3206msgstr "One or more device instances may be disabled"
3207msgid "SUN4U-8006-7X.impact"
3208msgstr "Loss of services provided by the device instances associated with this fault"
3209msgid "SUN4U-8006-7X.action"
3210msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
3211#
3212# code: SUN4U-8006-8P
3213# keys: fault.io.hbus fault.io.pci.bus fault.io.tomatillo
3214#
3215msgid "SUN4U-8006-8P.type"
3216msgstr "Fault"
3217msgid "SUN4U-8006-8P.severity"
3218msgstr "Critical"
3219msgid "SUN4U-8006-8P.description"
3220msgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
3221msgid "SUN4U-8006-8P.response"
3222msgstr "One or more device instances may be disabled"
3223msgid "SUN4U-8006-8P.impact"
3224msgstr "Loss of services provided by the device instances associated with this fault"
3225msgid "SUN4U-8006-8P.action"
3226msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
3227#
3228# code: SUN4U-8006-9A
3229# keys: defect.io.pci.driver fault.io.hbus fault.io.pci.bus fault.io.tomatillo
3230#
3231msgid "SUN4U-8006-9A.type"
3232msgstr "Fault"
3233msgid "SUN4U-8006-9A.severity"
3234msgstr "Critical"
3235msgid "SUN4U-8006-9A.description"
3236msgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
3237msgid "SUN4U-8006-9A.response"
3238msgstr "One or more device instances may be disabled"
3239msgid "SUN4U-8006-9A.impact"
3240msgstr "Loss of services provided by the device instances associated with this fault"
3241msgid "SUN4U-8006-9A.action"
3242msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
3243#
3244# code: SUN4U-8006-AS
3245# keys: fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.tomatillo
3246#
3247msgid "SUN4U-8006-AS.type"
3248msgstr "Fault"
3249msgid "SUN4U-8006-AS.severity"
3250msgstr "Critical"
3251msgid "SUN4U-8006-AS.description"
3252msgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
3253msgid "SUN4U-8006-AS.response"
3254msgstr "One or more device instances may be disabled"
3255msgid "SUN4U-8006-AS.impact"
3256msgstr "Loss of services provided by the device instances associated with this fault"
3257msgid "SUN4U-8006-AS.action"
3258msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
3259#
3260# code: SUN4U-8006-C5
3261# keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.tomatillo
3262#
3263msgid "SUN4U-8006-C5.type"
3264msgstr "Fault"
3265msgid "SUN4U-8006-C5.severity"
3266msgstr "Critical"
3267msgid "SUN4U-8006-C5.description"
3268msgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
3269msgid "SUN4U-8006-C5.response"
3270msgstr "One or more device instances may be disabled"
3271msgid "SUN4U-8006-C5.impact"
3272msgstr "Loss of services provided by the device instances associated with this fault"
3273msgid "SUN4U-8006-C5.action"
3274msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
3275#
3276# code: SUN4U-8006-DY
3277# keys: fault.io.pci.device fault.io.tomatillo
3278#
3279msgid "SUN4U-8006-DY.type"
3280msgstr "Fault"
3281msgid "SUN4U-8006-DY.severity"
3282msgstr "Critical"
3283msgid "SUN4U-8006-DY.description"
3284msgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
3285msgid "SUN4U-8006-DY.response"
3286msgstr "One or more device instances may be disabled"
3287msgid "SUN4U-8006-DY.impact"
3288msgstr "Loss of services provided by the device instances associated with this fault"
3289msgid "SUN4U-8006-DY.action"
3290msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
3291#
3292# code: SUN4U-8006-E3
3293# keys: defect.io.pci.driver fault.io.pci.device fault.io.tomatillo
3294#
3295msgid "SUN4U-8006-E3.type"
3296msgstr "Fault"
3297msgid "SUN4U-8006-E3.severity"
3298msgstr "Critical"
3299msgid "SUN4U-8006-E3.description"
3300msgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
3301msgid "SUN4U-8006-E3.response"
3302msgstr "One or more device instances may be disabled"
3303msgid "SUN4U-8006-E3.impact"
3304msgstr "Loss of services provided by the device instances associated with this fault"
3305msgid "SUN4U-8006-E3.action"
3306msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
3307#
3308# code: SUN4U-8006-FH
3309# keys: fault.io.datapath fault.io.pci.device fault.io.tomatillo
3310#
3311msgid "SUN4U-8006-FH.type"
3312msgstr "Fault"
3313msgid "SUN4U-8006-FH.severity"
3314msgstr "Critical"
3315msgid "SUN4U-8006-FH.description"
3316msgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
3317msgid "SUN4U-8006-FH.response"
3318msgstr "One or more device instances may be disabled"
3319msgid "SUN4U-8006-FH.impact"
3320msgstr "Loss of services provided by the device instances associated with this fault"
3321msgid "SUN4U-8006-FH.action"
3322msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
3323#
3324# code: SUN4U-8006-GD
3325# keys: defect.io.pci.driver fault.io.datapath fault.io.pci.device fault.io.tomatillo
3326#
3327msgid "SUN4U-8006-GD.type"
3328msgstr "Fault"
3329msgid "SUN4U-8006-GD.severity"
3330msgstr "Critical"
3331msgid "SUN4U-8006-GD.description"
3332msgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
3333msgid "SUN4U-8006-GD.response"
3334msgstr "One or more device instances may be disabled"
3335msgid "SUN4U-8006-GD.impact"
3336msgstr "Loss of services provided by the device instances associated with this fault"
3337msgid "SUN4U-8006-GD.action"
3338msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
3339#
3340# code: SUN4U-8006-HQ
3341# keys: fault.io.hbus fault.io.pci.device fault.io.tomatillo
3342#
3343msgid "SUN4U-8006-HQ.type"
3344msgstr "Fault"
3345msgid "SUN4U-8006-HQ.severity"
3346msgstr "Critical"
3347msgid "SUN4U-8006-HQ.description"
3348msgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
3349msgid "SUN4U-8006-HQ.response"
3350msgstr "One or more device instances may be disabled"
3351msgid "SUN4U-8006-HQ.impact"
3352msgstr "Loss of services provided by the device instances associated with this fault"
3353msgid "SUN4U-8006-HQ.action"
3354msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
3355#
3356# code: SUN4U-8006-JC
3357# keys: defect.io.pci.driver fault.io.hbus fault.io.pci.device fault.io.tomatillo
3358#
3359msgid "SUN4U-8006-JC.type"
3360msgstr "Fault"
3361msgid "SUN4U-8006-JC.severity"
3362msgstr "Critical"
3363msgid "SUN4U-8006-JC.description"
3364msgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
3365msgid "SUN4U-8006-JC.response"
3366msgstr "One or more device instances may be disabled"
3367msgid "SUN4U-8006-JC.impact"
3368msgstr "Loss of services provided by the device instances associated with this fault"
3369msgid "SUN4U-8006-JC.action"
3370msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
3371#
3372# code: SUN4U-8006-KR
3373# keys: fault.io.datapath fault.io.hbus fault.io.pci.device fault.io.tomatillo
3374#
3375msgid "SUN4U-8006-KR.type"
3376msgstr "Fault"
3377msgid "SUN4U-8006-KR.severity"
3378msgstr "Critical"
3379msgid "SUN4U-8006-KR.description"
3380msgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
3381msgid "SUN4U-8006-KR.response"
3382msgstr "One or more device instances may be disabled"
3383msgid "SUN4U-8006-KR.impact"
3384msgstr "Loss of services provided by the device instances associated with this fault"
3385msgid "SUN4U-8006-KR.action"
3386msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
3387#
3388# code: SUN4U-8006-L4
3389# keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.pci.device fault.io.tomatillo
3390#
3391msgid "SUN4U-8006-L4.type"
3392msgstr "Fault"
3393msgid "SUN4U-8006-L4.severity"
3394msgstr "Critical"
3395msgid "SUN4U-8006-L4.description"
3396msgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
3397msgid "SUN4U-8006-L4.response"
3398msgstr "One or more device instances may be disabled"
3399msgid "SUN4U-8006-L4.impact"
3400msgstr "Loss of services provided by the device instances associated with this fault"
3401msgid "SUN4U-8006-L4.action"
3402msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
3403#
3404# code: SUN4U-8006-MX
3405# keys: fault.io.pci.bus fault.io.pci.device fault.io.tomatillo
3406#
3407msgid "SUN4U-8006-MX.type"
3408msgstr "Fault"
3409msgid "SUN4U-8006-MX.severity"
3410msgstr "Critical"
3411msgid "SUN4U-8006-MX.description"
3412msgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
3413msgid "SUN4U-8006-MX.response"
3414msgstr "One or more device instances may be disabled"
3415msgid "SUN4U-8006-MX.impact"
3416msgstr "Loss of services provided by the device instances associated with this fault"
3417msgid "SUN4U-8006-MX.action"
3418msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
3419#
3420# code: SUN4U-8006-N2
3421# keys: defect.io.pci.driver fault.io.pci.bus fault.io.pci.device fault.io.tomatillo
3422#
3423msgid "SUN4U-8006-N2.type"
3424msgstr "Fault"
3425msgid "SUN4U-8006-N2.severity"
3426msgstr "Critical"
3427msgid "SUN4U-8006-N2.description"
3428msgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
3429msgid "SUN4U-8006-N2.response"
3430msgstr "One or more device instances may be disabled"
3431msgid "SUN4U-8006-N2.impact"
3432msgstr "Loss of services provided by the device instances associated with this fault"
3433msgid "SUN4U-8006-N2.action"
3434msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
3435#
3436# code: SUN4U-8006-PJ
3437# keys: fault.io.datapath fault.io.pci.bus fault.io.pci.device fault.io.tomatillo
3438#
3439msgid "SUN4U-8006-PJ.type"
3440msgstr "Fault"
3441msgid "SUN4U-8006-PJ.severity"
3442msgstr "Critical"
3443msgid "SUN4U-8006-PJ.description"
3444msgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
3445msgid "SUN4U-8006-PJ.response"
3446msgstr "One or more device instances may be disabled"
3447msgid "SUN4U-8006-PJ.impact"
3448msgstr "Loss of services provided by the device instances associated with this fault"
3449msgid "SUN4U-8006-PJ.action"
3450msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
3451#
3452# code: SUN4U-8006-QE
3453# keys: defect.io.pci.driver fault.io.datapath fault.io.pci.bus fault.io.pci.device fault.io.tomatillo
3454#
3455msgid "SUN4U-8006-QE.type"
3456msgstr "Fault"
3457msgid "SUN4U-8006-QE.severity"
3458msgstr "Critical"
3459msgid "SUN4U-8006-QE.description"
3460msgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
3461msgid "SUN4U-8006-QE.response"
3462msgstr "One or more device instances may be disabled"
3463msgid "SUN4U-8006-QE.impact"
3464msgstr "Loss of services provided by the device instances associated with this fault"
3465msgid "SUN4U-8006-QE.action"
3466msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
3467#
3468# code: SUN4U-8006-R5
3469# keys: fault.io.hbus fault.io.pci.bus fault.io.pci.device fault.io.tomatillo
3470#
3471msgid "SUN4U-8006-R5.type"
3472msgstr "Fault"
3473msgid "SUN4U-8006-R5.severity"
3474msgstr "Critical"
3475msgid "SUN4U-8006-R5.description"
3476msgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
3477msgid "SUN4U-8006-R5.response"
3478msgstr "One or more device instances may be disabled"
3479msgid "SUN4U-8006-R5.impact"
3480msgstr "Loss of services provided by the device instances associated with this fault"
3481msgid "SUN4U-8006-R5.action"
3482msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
3483#
3484# code: SUN4U-8006-SS
3485# keys: defect.io.pci.driver fault.io.hbus fault.io.pci.bus fault.io.pci.device fault.io.tomatillo
3486#
3487msgid "SUN4U-8006-SS.type"
3488msgstr "Fault"
3489msgid "SUN4U-8006-SS.severity"
3490msgstr "Critical"
3491msgid "SUN4U-8006-SS.description"
3492msgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
3493msgid "SUN4U-8006-SS.response"
3494msgstr "One or more device instances may be disabled"
3495msgid "SUN4U-8006-SS.impact"
3496msgstr "Loss of services provided by the device instances associated with this fault"
3497msgid "SUN4U-8006-SS.action"
3498msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
3499#
3500# code: SUN4U-8006-TA
3501# keys: fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.pci.device fault.io.tomatillo
3502#
3503msgid "SUN4U-8006-TA.type"
3504msgstr "Fault"
3505msgid "SUN4U-8006-TA.severity"
3506msgstr "Critical"
3507msgid "SUN4U-8006-TA.description"
3508msgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
3509msgid "SUN4U-8006-TA.response"
3510msgstr "One or more device instances may be disabled"
3511msgid "SUN4U-8006-TA.impact"
3512msgstr "Loss of services provided by the device instances associated with this fault"
3513msgid "SUN4U-8006-TA.action"
3514msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
3515#
3516# code: SUN4U-8006-UP
3517# keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.pci.device fault.io.tomatillo
3518#
3519msgid "SUN4U-8006-UP.type"
3520msgstr "Fault"
3521msgid "SUN4U-8006-UP.severity"
3522msgstr "Critical"
3523msgid "SUN4U-8006-UP.description"
3524msgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
3525msgid "SUN4U-8006-UP.response"
3526msgstr "One or more device instances may be disabled"
3527msgid "SUN4U-8006-UP.impact"
3528msgstr "Loss of services provided by the device instances associated with this fault"
3529msgid "SUN4U-8006-UP.action"
3530msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
3531#
3532# code: SUN4U-8006-VD
3533# keys: fault.cpu.ultraSPARC-IIIiplus.dcache
3534#
3535msgid "SUN4U-8006-VD.type"
3536msgstr "Fault"
3537msgid "SUN4U-8006-VD.severity"
3538msgstr "Major"
3539msgid "SUN4U-8006-VD.description"
3540msgstr "The number of errors associated with this CPU has exceeded acceptable levels.  Refer to %s for more information."
3541msgid "SUN4U-8006-VD.response"
3542msgstr "An attempt will be made to remove the affected CPU from service."
3543msgid "SUN4U-8006-VD.impact"
3544msgstr "Performance of this system may be affected."
3545msgid "SUN4U-8006-VD.action"
3546msgstr "Schedule a repair procedure to replace the affected CPU.  Use fmdump -v -u <EVENT_ID> to identify the CPU."
3547#
3548# code: SUN4U-8006-WH
3549# keys: fault.cpu.ultraSPARC-IIIiplus.icache
3550#
3551msgid "SUN4U-8006-WH.type"
3552msgstr "Fault"
3553msgid "SUN4U-8006-WH.severity"
3554msgstr "Major"
3555msgid "SUN4U-8006-WH.description"
3556msgstr "The number of errors associated with this CPU has exceeded acceptable levels.  Refer to %s for more information."
3557msgid "SUN4U-8006-WH.response"
3558msgstr "An attempt will be made to remove the affected CPU from service."
3559msgid "SUN4U-8006-WH.impact"
3560msgstr "Performance of this system may be affected."
3561msgid "SUN4U-8006-WH.action"
3562msgstr "Schedule a repair procedure to replace the affected CPU.  Use fmdump -v -u <EVENT_ID> to identify the CPU."
3563#
3564# code: SUN4U-8006-X3
3565# keys: fault.cpu.ultraSPARC-IIIiplus.l2cachedata
3566#
3567msgid "SUN4U-8006-X3.type"
3568msgstr "Fault"
3569msgid "SUN4U-8006-X3.severity"
3570msgstr "Major"
3571msgid "SUN4U-8006-X3.description"
3572msgstr "The number of errors associated with this CPU has exceeded acceptable levels.  Refer to %s for more information."
3573msgid "SUN4U-8006-X3.response"
3574msgstr "An attempt will be made to remove the affected CPU from service."
3575msgid "SUN4U-8006-X3.impact"
3576msgstr "Performance of this system may be affected."
3577msgid "SUN4U-8006-X3.action"
3578msgstr "Schedule a repair procedure to replace the affected CPU.  Use fmdump -v -u <EVENT_ID> to identify the CPU."
3579#
3580# code: SUN4U-8006-YY
3581# keys: fault.cpu.ultraSPARC-IIIiplus.l2cachetag
3582#
3583msgid "SUN4U-8006-YY.type"
3584msgstr "Fault"
3585msgid "SUN4U-8006-YY.severity"
3586msgstr "Major"
3587msgid "SUN4U-8006-YY.description"
3588msgstr "The number of errors associated with this CPU has exceeded acceptable levels.  Refer to %s for more information."
3589msgid "SUN4U-8006-YY.response"
3590msgstr "An attempt will be made to remove the affected CPU from service."
3591msgid "SUN4U-8006-YY.impact"
3592msgstr "Performance of this system may be affected."
3593msgid "SUN4U-8006-YY.action"
3594msgstr "Schedule a repair procedure to replace the affected CPU.  Use fmdump -v -u <EVENT_ID> to identify the CPU."
3595#
3596# code: SUN4U-8007-03
3597# keys: fault.cpu.ultraSPARC-IIIiplus.fpu
3598#
3599msgid "SUN4U-8007-03.type"
3600msgstr "Fault"
3601msgid "SUN4U-8007-03.severity"
3602msgstr "Major"
3603msgid "SUN4U-8007-03.description"
3604msgstr "A fault has been detected in the FPU of this CPU.  Refer to %s for more information."
3605msgid "SUN4U-8007-03.response"
3606msgstr "An attempt will be made to remove the affected CPU from service."
3607msgid "SUN4U-8007-03.impact"
3608msgstr "Performance of this system may be affected."
3609msgid "SUN4U-8007-03.action"
3610msgstr "Schedule a repair procedure to replace the affected CPU.  Use fmdump -v -u <EVENT_ID> to identify the CPU."
3611