17c478bd9Sstevel@tonic-gate# 2*05dd151bSStephen Hanson# Copyright 2009 Sun Microsystems, Inc. All rights reserved. 37c478bd9Sstevel@tonic-gate# Use is subject to license terms. 47c478bd9Sstevel@tonic-gate# 57c478bd9Sstevel@tonic-gate# CDDL HEADER START 67c478bd9Sstevel@tonic-gate# 77c478bd9Sstevel@tonic-gate# The contents of this file are subject to the terms of the 800d0963fSdilpreet# Common Development and Distribution License (the "License"). 900d0963fSdilpreet# You may not use this file except in compliance with the License. 107c478bd9Sstevel@tonic-gate# 117c478bd9Sstevel@tonic-gate# You can obtain a copy of the license at usr/src/OPENSOLARIS.LICENSE 127c478bd9Sstevel@tonic-gate# or http://www.opensolaris.org/os/licensing. 137c478bd9Sstevel@tonic-gate# See the License for the specific language governing permissions 147c478bd9Sstevel@tonic-gate# and limitations under the License. 157c478bd9Sstevel@tonic-gate# 167c478bd9Sstevel@tonic-gate# When distributing Covered Code, include this CDDL HEADER in each 177c478bd9Sstevel@tonic-gate# file and include the License file at usr/src/OPENSOLARIS.LICENSE. 187c478bd9Sstevel@tonic-gate# If applicable, add the following below this CDDL HEADER, with the 197c478bd9Sstevel@tonic-gate# fields enclosed by brackets "[]" replaced with your own identifying 207c478bd9Sstevel@tonic-gate# information: Portions Copyright [yyyy] [name of copyright owner] 217c478bd9Sstevel@tonic-gate# 227c478bd9Sstevel@tonic-gate# CDDL HEADER END 237c478bd9Sstevel@tonic-gate# 2400d0963fSdilpreet# DO NOT EDIT -- this file is generated by the Event Registry. 2500d0963fSdilpreet# 267c478bd9Sstevel@tonic-gate# 277c478bd9Sstevel@tonic-gate# code: PCI-8000-0C 287c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver 297c478bd9Sstevel@tonic-gate# 307c478bd9Sstevel@tonic-gatemsgid "PCI-8000-0C.type" 317c478bd9Sstevel@tonic-gatemsgstr "Fault" 327c478bd9Sstevel@tonic-gatemsgid "PCI-8000-0C.severity" 337c478bd9Sstevel@tonic-gatemsgstr "Critical" 347c478bd9Sstevel@tonic-gatemsgid "PCI-8000-0C.description" 3500d0963fSdilpreetmsgstr "A problem was detected in the PCI controller software. Refer to %s for more information." 367c478bd9Sstevel@tonic-gatemsgid "PCI-8000-0C.response" 3700d0963fSdilpreetmsgstr "One or more of device instances may be disabled." 387c478bd9Sstevel@tonic-gatemsgid "PCI-8000-0C.impact" 3900d0963fSdilpreetmsgstr "Loss of services provided by the device instances associated with this problem." 407c478bd9Sstevel@tonic-gatemsgid "PCI-8000-0C.action" 417c478bd9Sstevel@tonic-gatemsgstr "Ensure latest drivers and patches are installed. Use fmdump -v -u <EVENT_ID> to identify the module/package, or contact Sun for support." 427c478bd9Sstevel@tonic-gate# 437c478bd9Sstevel@tonic-gate# code: PCI-8000-1Q 447c478bd9Sstevel@tonic-gate# keys: fault.io.pci.bus 457c478bd9Sstevel@tonic-gate# 467c478bd9Sstevel@tonic-gatemsgid "PCI-8000-1Q.type" 477c478bd9Sstevel@tonic-gatemsgstr "Fault" 487c478bd9Sstevel@tonic-gatemsgid "PCI-8000-1Q.severity" 497c478bd9Sstevel@tonic-gatemsgstr "Critical" 507c478bd9Sstevel@tonic-gatemsgid "PCI-8000-1Q.description" 517c478bd9Sstevel@tonic-gatemsgstr "A problem was detected for a PCI bus. Refer to %s for more information." 527c478bd9Sstevel@tonic-gatemsgid "PCI-8000-1Q.response" 5300d0963fSdilpreetmsgstr "One or more device instances may be disabled." 547c478bd9Sstevel@tonic-gatemsgid "PCI-8000-1Q.impact" 5500d0963fSdilpreetmsgstr "Loss of services provided by the device instances associated with this fault." 567c478bd9Sstevel@tonic-gatemsgid "PCI-8000-1Q.action" 577c478bd9Sstevel@tonic-gatemsgstr "Schedule a repair procedure to replace the affected device. Use fmdump -v -u <EVENT_ID> to identify the device or contact Sun for support." 587c478bd9Sstevel@tonic-gate# 597c478bd9Sstevel@tonic-gate# code: PCI-8000-24 607c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.pci.bus 617c478bd9Sstevel@tonic-gate# 627c478bd9Sstevel@tonic-gatemsgid "PCI-8000-24.type" 637c478bd9Sstevel@tonic-gatemsgstr "Fault" 647c478bd9Sstevel@tonic-gatemsgid "PCI-8000-24.severity" 657c478bd9Sstevel@tonic-gatemsgstr "Critical" 667c478bd9Sstevel@tonic-gatemsgid "PCI-8000-24.description" 6700d0963fSdilpreetmsgstr "The system has diagnosed a problem, the suspects include one or more \nPCI buses and one or more PCI controller drivers. Refer to %s for more information." 687c478bd9Sstevel@tonic-gatemsgid "PCI-8000-24.response" 6900d0963fSdilpreetmsgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 707c478bd9Sstevel@tonic-gatemsgid "PCI-8000-24.impact" 7100d0963fSdilpreetmsgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 727c478bd9Sstevel@tonic-gatemsgid "PCI-8000-24.action" 7300d0963fSdilpreetmsgstr "Use fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s)or driver(s).\n\nCheck for patches to identified device drivers, schedule a repair for \nindicated hardware.\n" 747c478bd9Sstevel@tonic-gate# 757c478bd9Sstevel@tonic-gate# code: PCI-8000-3R 767c478bd9Sstevel@tonic-gate# keys: fault.io.pci.device 777c478bd9Sstevel@tonic-gate# 787c478bd9Sstevel@tonic-gatemsgid "PCI-8000-3R.type" 797c478bd9Sstevel@tonic-gatemsgstr "Fault" 807c478bd9Sstevel@tonic-gatemsgid "PCI-8000-3R.severity" 817c478bd9Sstevel@tonic-gatemsgstr "Critical" 827c478bd9Sstevel@tonic-gatemsgid "PCI-8000-3R.description" 8300d0963fSdilpreetmsgstr "The system has diagnosed a problem in one or more PCI buses or devices, \nbased on the error telemetry detected by the PCI subsystem. Refer to %s for more information." 847c478bd9Sstevel@tonic-gatemsgid "PCI-8000-3R.response" 8500d0963fSdilpreetmsgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 867c478bd9Sstevel@tonic-gatemsgid "PCI-8000-3R.impact" 8700d0963fSdilpreetmsgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 887c478bd9Sstevel@tonic-gatemsgid "PCI-8000-3R.action" 8900d0963fSdilpreetmsgstr "Use fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).\n\nSchedule a repair procedure to replace the affected device." 907c478bd9Sstevel@tonic-gate# 917c478bd9Sstevel@tonic-gate# code: PCI-8000-42 927c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.pci.device 937c478bd9Sstevel@tonic-gate# 947c478bd9Sstevel@tonic-gatemsgid "PCI-8000-42.type" 957c478bd9Sstevel@tonic-gatemsgstr "Fault" 967c478bd9Sstevel@tonic-gatemsgid "PCI-8000-42.severity" 977c478bd9Sstevel@tonic-gatemsgstr "Critical" 987c478bd9Sstevel@tonic-gatemsgid "PCI-8000-42.description" 9900d0963fSdilpreetmsgstr "The system has diagnosed a problem, the suspects include one or more \nPCI buses and one or more PCI controller drivers. Refer to %s for more information." 1007c478bd9Sstevel@tonic-gatemsgid "PCI-8000-42.response" 10100d0963fSdilpreetmsgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 1027c478bd9Sstevel@tonic-gatemsgid "PCI-8000-42.impact" 10300d0963fSdilpreetmsgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 1047c478bd9Sstevel@tonic-gatemsgid "PCI-8000-42.action" 10500d0963fSdilpreetmsgstr "Use fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s)or driver(s).\n\nCheck for patches to identified device drivers, schedule a repair for \nindicated hardware.\n" 1067c478bd9Sstevel@tonic-gate# 1077c478bd9Sstevel@tonic-gate# code: PCI-8000-5X 1087c478bd9Sstevel@tonic-gate# keys: fault.io.pci.bus fault.io.pci.device 1097c478bd9Sstevel@tonic-gate# 1107c478bd9Sstevel@tonic-gatemsgid "PCI-8000-5X.type" 1117c478bd9Sstevel@tonic-gatemsgstr "Fault" 1127c478bd9Sstevel@tonic-gatemsgid "PCI-8000-5X.severity" 1137c478bd9Sstevel@tonic-gatemsgstr "Critical" 1147c478bd9Sstevel@tonic-gatemsgid "PCI-8000-5X.description" 11500d0963fSdilpreetmsgstr "The system has diagnosed a problem in one or more PCI buses or devices, \nbased on the error telemetry detected by the PCI subsystem. Refer to %s for more information." 1167c478bd9Sstevel@tonic-gatemsgid "PCI-8000-5X.response" 11700d0963fSdilpreetmsgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 1187c478bd9Sstevel@tonic-gatemsgid "PCI-8000-5X.impact" 11900d0963fSdilpreetmsgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 1207c478bd9Sstevel@tonic-gatemsgid "PCI-8000-5X.action" 12100d0963fSdilpreetmsgstr "Use fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).\n\nSchedule a repair procedure to replace the affected device." 1227c478bd9Sstevel@tonic-gate# 1237c478bd9Sstevel@tonic-gate# code: PCI-8000-6E 1247c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.pci.bus fault.io.pci.device 1257c478bd9Sstevel@tonic-gate# 1267c478bd9Sstevel@tonic-gatemsgid "PCI-8000-6E.type" 1277c478bd9Sstevel@tonic-gatemsgstr "Fault" 1287c478bd9Sstevel@tonic-gatemsgid "PCI-8000-6E.severity" 1297c478bd9Sstevel@tonic-gatemsgstr "Critical" 1307c478bd9Sstevel@tonic-gatemsgid "PCI-8000-6E.description" 13100d0963fSdilpreetmsgstr "The system has diagnosed a problem, the suspects include one or more \nPCI buses and one or more PCI controller drivers. Refer to %s for more information." 1327c478bd9Sstevel@tonic-gatemsgid "PCI-8000-6E.response" 13300d0963fSdilpreetmsgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 1347c478bd9Sstevel@tonic-gatemsgid "PCI-8000-6E.impact" 13500d0963fSdilpreetmsgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 1367c478bd9Sstevel@tonic-gatemsgid "PCI-8000-6E.action" 13700d0963fSdilpreetmsgstr "Use fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s)or driver(s).\n\nCheck for patches to identified device drivers, schedule a repair for \nindicated hardware.\n" 13800d0963fSdilpreet# 13900d0963fSdilpreet# code: PCI-8000-7J 14000d0963fSdilpreet# keys: fault.io.pci.device-interr 14100d0963fSdilpreet# 14200d0963fSdilpreetmsgid "PCI-8000-7J.type" 14300d0963fSdilpreetmsgstr "Fault" 14400d0963fSdilpreetmsgid "PCI-8000-7J.severity" 14500d0963fSdilpreetmsgstr "Critical" 14600d0963fSdilpreetmsgid "PCI-8000-7J.description" 147b7d3956bSstephhmsgstr "An unrecoverable problem was detected for a PCI device.\n Refer to %s for more information." 14800d0963fSdilpreetmsgid "PCI-8000-7J.response" 14900d0963fSdilpreetmsgstr "One or more device instances may be disabled\n" 15000d0963fSdilpreetmsgid "PCI-8000-7J.impact" 15100d0963fSdilpreetmsgstr "Possible loss of services provided by the device instances associated with this fault\n" 15200d0963fSdilpreetmsgid "PCI-8000-7J.action" 153b7d3956bSstephhmsgstr "Schedule a repair procedure to replace the affected device. Use fmadm faulty to identify the device or contact Sun for support.\n" 15400d0963fSdilpreet# 15500d0963fSdilpreet# code: PCI-8000-8S 15600d0963fSdilpreet# keys: fault.io.pci.bus-linkerr fault.io.pci.device-interr 15700d0963fSdilpreet# 15800d0963fSdilpreetmsgid "PCI-8000-8S.type" 15900d0963fSdilpreetmsgstr "Fault" 16000d0963fSdilpreetmsgid "PCI-8000-8S.severity" 16100d0963fSdilpreetmsgstr "Critical" 16200d0963fSdilpreetmsgid "PCI-8000-8S.description" 163b7d3956bSstephhmsgstr "An unrecoverable problem has been detected on the specified bus or on the specified transmitting device.\n Refer to %s for more information." 16400d0963fSdilpreetmsgid "PCI-8000-8S.response" 16500d0963fSdilpreetmsgstr "One or more device instances may be disabled\n" 16600d0963fSdilpreetmsgid "PCI-8000-8S.impact" 16700d0963fSdilpreetmsgstr "Possible loss of services provided by the device instances associated with this fault\n" 16800d0963fSdilpreetmsgid "PCI-8000-8S.action" 169b7d3956bSstephhmsgstr "If a plug-in card is involved check for badly-seated cards or bent pins. Otherwise schedule a repair procedure to replace the affected device. Use fmadm faulty to identify the device and bus or contact Sun for support.\n" 17000d0963fSdilpreet# 17100d0963fSdilpreet# code: PCI-8000-95 17200d0963fSdilpreet# keys: fault.io.pci.device-invreq fault.io.pci.device-noresp 17300d0963fSdilpreet# 17400d0963fSdilpreetmsgid "PCI-8000-95.type" 17500d0963fSdilpreetmsgstr "Fault" 17600d0963fSdilpreetmsgid "PCI-8000-95.severity" 177b7d3956bSstephhmsgstr "Major" 17800d0963fSdilpreetmsgid "PCI-8000-95.description" 17900d0963fSdilpreetmsgstr "Either the transmitting device sent an invalid request or the receiving device failed to respond.\n Refer to %s for more information." 18000d0963fSdilpreetmsgid "PCI-8000-95.response" 18100d0963fSdilpreetmsgstr "One or more device instances may be disabled\n" 18200d0963fSdilpreetmsgid "PCI-8000-95.impact" 18300d0963fSdilpreetmsgstr "Possible loss of services provided by the device instances associated with this fault\n" 18400d0963fSdilpreetmsgid "PCI-8000-95.action" 185b7d3956bSstephhmsgstr "Ensure that the latest drivers and patches are installed. If a plug-in card is involved check for badly-seated cards or bent pins. Otherwise schedule a repair procedure to replace the affected device(s). Use fmadm faulty to identify the devices or contact Sun for support.\n" 18600d0963fSdilpreet# 18700d0963fSdilpreet# code: PCI-8000-AP 18800d0963fSdilpreet# keys: fault.io.pci.device-interr fault.io.pci.device-invreq 18900d0963fSdilpreet# 19000d0963fSdilpreetmsgid "PCI-8000-AP.type" 19100d0963fSdilpreetmsgstr "Fault" 19200d0963fSdilpreetmsgid "PCI-8000-AP.severity" 193b7d3956bSstephhmsgstr "Major" 19400d0963fSdilpreetmsgid "PCI-8000-AP.description" 19500d0963fSdilpreetmsgstr "Either the transmitting device sent an invalid request or the receiving device is reporting an internal fault.\n Refer to %s for more information." 19600d0963fSdilpreetmsgid "PCI-8000-AP.response" 19700d0963fSdilpreetmsgstr "One or more device instances may be disabled\n" 19800d0963fSdilpreetmsgid "PCI-8000-AP.impact" 19900d0963fSdilpreetmsgstr "Possible loss of services provided by the device instances associated with this fault\n" 20000d0963fSdilpreetmsgid "PCI-8000-AP.action" 201b7d3956bSstephhmsgstr "Ensure that the latest drivers and patches are installed. Otherwise schedule a repair procedure to replace the affected device(s). Use fmadm faulty to identify the devices or contact Sun for support.\n" 20200d0963fSdilpreet# 20300d0963fSdilpreet# code: PCI-8000-CA 20400d0963fSdilpreet# keys: fault.io.pci.device-noresp 20500d0963fSdilpreet# 20600d0963fSdilpreetmsgid "PCI-8000-CA.type" 20700d0963fSdilpreetmsgstr "Fault" 20800d0963fSdilpreetmsgid "PCI-8000-CA.severity" 209b7d3956bSstephhmsgstr "Major" 21000d0963fSdilpreetmsgid "PCI-8000-CA.description" 2119dd0f810Scindimsgstr "A device is failing to respond\n Refer to %s for more information." 21200d0963fSdilpreetmsgid "PCI-8000-CA.response" 21300d0963fSdilpreetmsgstr "One or more device instances may be disabled\n" 21400d0963fSdilpreetmsgid "PCI-8000-CA.impact" 21500d0963fSdilpreetmsgstr "Possible loss of services provided by the device instances associated with this fault\n" 21600d0963fSdilpreetmsgid "PCI-8000-CA.action" 217b7d3956bSstephhmsgstr "Schedule a repair procedure to replace the affected device. Use fmadm faulty to identify the device or contact Sun for support.\n" 218b7d3956bSstephh# 219b7d3956bSstephh# code: PCI-8000-DH 220b7d3956bSstephh# keys: fault.io.pci.bus-linkerr-unaf fault.io.pci.device-interr-unaf 221b7d3956bSstephh# 222b7d3956bSstephhmsgid "PCI-8000-DH.type" 223b7d3956bSstephhmsgstr "Fault" 224b7d3956bSstephhmsgid "PCI-8000-DH.severity" 225b7d3956bSstephhmsgstr "Major" 226b7d3956bSstephhmsgid "PCI-8000-DH.description" 227b7d3956bSstephhmsgstr "Too many recovered bus faults have been detected, which indicates a problem with the specified bus or with the specified transmitting device. This may degrade into an unrecoverable fault.\n Refer to %s for more information." 228b7d3956bSstephhmsgid "PCI-8000-DH.response" 229b7d3956bSstephhmsgstr "One or more device instances may be disabled\n" 230b7d3956bSstephhmsgid "PCI-8000-DH.impact" 231b7d3956bSstephhmsgstr "Possible loss of services provided by the device instances associated with this fault\n" 232b7d3956bSstephhmsgid "PCI-8000-DH.action" 233b7d3956bSstephhmsgstr "If a plug-in card is involved check for badly-seated cards or bent pins. Otherwise schedule a repair procedure to replace the affected device. Use fmadm faulty to identify the device and bus or contact Sun for support.\n" 234b7d3956bSstephh# 235b7d3956bSstephh# code: PCI-8000-ED 236b7d3956bSstephh# keys: fault.io.pci.device-interr-corr 237b7d3956bSstephh# 238b7d3956bSstephhmsgid "PCI-8000-ED.type" 239b7d3956bSstephhmsgstr "Fault" 240b7d3956bSstephhmsgid "PCI-8000-ED.severity" 241b7d3956bSstephhmsgstr "Major" 242b7d3956bSstephhmsgid "PCI-8000-ED.description" 243b7d3956bSstephhmsgstr "Too many recovered internal faults have been detected within the specified PCI device. This may degrade into a non-recoverable fault.\n Refer to %s for more information." 244b7d3956bSstephhmsgid "PCI-8000-ED.response" 245b7d3956bSstephhmsgstr "One or more device instances may be disabled\n" 246b7d3956bSstephhmsgid "PCI-8000-ED.impact" 247b7d3956bSstephhmsgstr "Possible loss of services provided by the device instances associated with this fault\n" 248b7d3956bSstephhmsgid "PCI-8000-ED.action" 249b7d3956bSstephhmsgstr "Schedule a repair procedure to replace the affected device. Use fmadm faulty to identify the device or contact Sun for support.\n" 250b7d3956bSstephh# 251b7d3956bSstephh# code: PCI-8000-FY 252b7d3956bSstephh# keys: fault.io.pci.bus-linkerr-deg fault.io.pci.device-interr-deg 253b7d3956bSstephh# 254b7d3956bSstephhmsgid "PCI-8000-FY.type" 255b7d3956bSstephhmsgstr "Fault" 256b7d3956bSstephhmsgid "PCI-8000-FY.severity" 257b7d3956bSstephhmsgstr "Major" 258b7d3956bSstephhmsgid "PCI-8000-FY.description" 259b7d3956bSstephhmsgstr "An unrecoverable problem has been detected on the specified bus or on the specified transmitting device, which has resulted in that device running in a degraded state.\n Refer to %s for more information." 260b7d3956bSstephhmsgid "PCI-8000-FY.response" 261b7d3956bSstephhmsgstr "None\n" 262b7d3956bSstephhmsgid "PCI-8000-FY.impact" 263b7d3956bSstephhmsgstr "Degraded services provided by the device instances associated with this fault\n" 264b7d3956bSstephhmsgid "PCI-8000-FY.action" 265b7d3956bSstephhmsgstr "If a plug-in card is involved check for badly-seated cards or bent pins. Otherwise schedule a repair procedure to replace the affected device. Use fmadm faulty to identify the device and bus or contact Sun for support.\n" 266b7d3956bSstephh# 267b7d3956bSstephh# code: PCI-8000-G3 268b7d3956bSstephh# keys: fault.io.pci.device-interr-deg 269b7d3956bSstephh# 270b7d3956bSstephhmsgid "PCI-8000-G3.type" 271b7d3956bSstephhmsgstr "Fault" 272b7d3956bSstephhmsgid "PCI-8000-G3.severity" 273b7d3956bSstephhmsgstr "Major" 274b7d3956bSstephhmsgid "PCI-8000-G3.description" 275b7d3956bSstephhmsgstr "An unrecoverable problem was detected for a PCI device, which has resulted in that device running in a degraded state.\n Refer to %s for more information." 276b7d3956bSstephhmsgid "PCI-8000-G3.response" 277b7d3956bSstephhmsgstr "None\n" 278b7d3956bSstephhmsgid "PCI-8000-G3.impact" 279b7d3956bSstephhmsgstr "Degraded services provided by the device instances associated with this fault\n" 280b7d3956bSstephhmsgid "PCI-8000-G3.action" 281b7d3956bSstephhmsgstr "Schedule a repair procedure to replace the affected device. Use fmadm faulty to identify the device or contact Sun for support.\n" 282*05dd151bSStephen Hanson# 283*05dd151bSStephen Hanson# code: PCI-8000-HR 284*05dd151bSStephen Hanson# keys: fault.io.pci.fw_corrupt 285*05dd151bSStephen Hanson# 286*05dd151bSStephen Hansonmsgid "PCI-8000-HR.type" 287*05dd151bSStephen Hansonmsgstr "Fault" 288*05dd151bSStephen Hansonmsgid "PCI-8000-HR.severity" 289*05dd151bSStephen Hansonmsgstr "Major" 290*05dd151bSStephen Hansonmsgid "PCI-8000-HR.description" 291*05dd151bSStephen Hansonmsgstr "A firmware corruption was detected for a PCI device.\n Refer to %s for more information." 292*05dd151bSStephen Hansonmsgid "PCI-8000-HR.response" 293*05dd151bSStephen Hansonmsgstr "One or more device instances may be disabled.\n" 294*05dd151bSStephen Hansonmsgid "PCI-8000-HR.impact" 295*05dd151bSStephen Hansonmsgstr "Degraded services provided by the device instances associated with this fault.\n" 296*05dd151bSStephen Hansonmsgid "PCI-8000-HR.action" 297*05dd151bSStephen Hansonmsgstr "Use fmadm faulty to identify the device and then update the firmware to the latest version or schedule a repair procedure to replace the affected device. Contact Sun support for further information.\n" 298*05dd151bSStephen Hanson# 299*05dd151bSStephen Hanson# code: PCI-8000-J4 300*05dd151bSStephen Hanson# keys: fault.io.pci.fw_mismatch 301*05dd151bSStephen Hanson# 302*05dd151bSStephen Hansonmsgid "PCI-8000-J4.type" 303*05dd151bSStephen Hansonmsgstr "Fault" 304*05dd151bSStephen Hansonmsgid "PCI-8000-J4.severity" 305*05dd151bSStephen Hansonmsgstr "Major" 306*05dd151bSStephen Hansonmsgid "PCI-8000-J4.description" 307*05dd151bSStephen Hansonmsgstr "A firmware version mismatch was detected for a PCI device.\n Refer to %s for more information." 308*05dd151bSStephen Hansonmsgid "PCI-8000-J4.response" 309*05dd151bSStephen Hansonmsgstr "One or more device instances may be disabled.\n" 310*05dd151bSStephen Hansonmsgid "PCI-8000-J4.impact" 311*05dd151bSStephen Hansonmsgstr "Degraded services provided by the device instances associated with this fault.\n" 312*05dd151bSStephen Hansonmsgid "PCI-8000-J4.action" 313*05dd151bSStephen Hansonmsgstr "Use fmadm faulty to identify the device and then update the firmware to the latest version. Contact Sun support for further information.\n" 314