xref: /titanic_50/usr/src/cmd/fm/dicts/SUN4U.po (revision db3659e514c8bf3f03bcca6dd082e363bd7b466a)
1#
2# Copyright 2008 Sun Microsystems, Inc.  All rights reserved.
3# Use is subject to license terms.
4#
5# CDDL HEADER START
6#
7# The contents of this file are subject to the terms of the
8# Common Development and Distribution License (the "License").
9# You may not use this file except in compliance with the License.
10#
11# You can obtain a copy of the license at usr/src/OPENSOLARIS.LICENSE
12# or http://www.opensolaris.org/os/licensing.
13# See the License for the specific language governing permissions
14# and limitations under the License.
15#
16# When distributing Covered Code, include this CDDL HEADER in each
17# file and include the License file at usr/src/OPENSOLARIS.LICENSE.
18# If applicable, add the following below this CDDL HEADER, with the
19# fields enclosed by brackets "[]" replaced with your own identifying
20# information: Portions Copyright [yyyy] [name of copyright owner]
21#
22# CDDL HEADER END
23#
24#
25# DO NOT EDIT -- this file is generated by the Event Registry.
26#
27#
28# code: SUN4U-8000-1A
29# keys: fault.memory.page
30#
31msgid "SUN4U-8000-1A.type"
32msgstr "Fault"
33msgid "SUN4U-8000-1A.severity"
34msgstr "Minor"
35msgid "SUN4U-8000-1A.description"
36msgstr "The number of errors associated with this memory module continues to exceed acceptable levels.  Refer to %s for more information."
37msgid "SUN4U-8000-1A.response"
38msgstr "An attempt will be made to remove this memory page from service."
39msgid "SUN4U-8000-1A.impact"
40msgstr "The performance of the system may be minimally impacted as a result of removing the memory page from operation."
41msgid "SUN4U-8000-1A.action"
42msgstr "No repair action is recommended at this time."
43#
44# code: SUN4U-8000-2S
45# keys: fault.memory.dimm
46#
47msgid "SUN4U-8000-2S.type"
48msgstr "Fault"
49msgid "SUN4U-8000-2S.severity"
50msgstr "Major"
51msgid "SUN4U-8000-2S.description"
52msgstr "The number of errors associated with this memory module has exceeded acceptable levels.  Refer to %s for more information."
53msgid "SUN4U-8000-2S.response"
54msgstr "Pages of memory associated with this memory module are being removed from service as errors are reported."
55msgid "SUN4U-8000-2S.impact"
56msgstr "Total system memory capacity will be reduced as pages are retired."
57msgid "SUN4U-8000-2S.action"
58msgstr "Schedule a repair procedure to replace the affected memory module. Use fmdump -v -u <EVENT_ID> to identify the module."
59#
60# code: SUN4U-8000-35
61# keys: fault.memory.bank
62#
63msgid "SUN4U-8000-35.type"
64msgstr "Fault"
65msgid "SUN4U-8000-35.severity"
66msgstr "Critical"
67msgid "SUN4U-8000-35.description"
68msgstr "The number of errors associated with this memory module has exceeded acceptable levels.  Refer to %s for more information."
69msgid "SUN4U-8000-35.response"
70msgstr "Pages of memory associated with this memory module are being removed from service as errors are reported."
71msgid "SUN4U-8000-35.impact"
72msgstr "Total system memory capacity will be reduced as pages are retired."
73msgid "SUN4U-8000-35.action"
74msgstr "Schedule a repair procedure to replace the affected memory module. Use fmdump -v -u <EVENT_ID> to identify the module."
75#
76# code: SUN4U-8000-4Y
77# keys: fault.cpu.ultraSPARC-III.dcache
78#
79msgid "SUN4U-8000-4Y.type"
80msgstr "Fault"
81msgid "SUN4U-8000-4Y.severity"
82msgstr "Major"
83msgid "SUN4U-8000-4Y.description"
84msgstr "The number of errors associated with a CPU has exceeded acceptable levels.  Refer to %s for more information."
85msgid "SUN4U-8000-4Y.response"
86msgstr "The fault manager will attempt to remove the affected CPU from service."
87msgid "SUN4U-8000-4Y.impact"
88msgstr "System performance may be affected."
89msgid "SUN4U-8000-4Y.action"
90msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>."
91#
92# code: SUN4U-8000-53
93# keys: fault.cpu.ultraSPARC-III.icache
94#
95msgid "SUN4U-8000-53.type"
96msgstr "Fault"
97msgid "SUN4U-8000-53.severity"
98msgstr "Major"
99msgid "SUN4U-8000-53.description"
100msgstr "The number of errors associated with a CPU has exceeded acceptable levels.  Refer to %s for more information."
101msgid "SUN4U-8000-53.response"
102msgstr "The fault manager will attempt to remove the affected CPU from service."
103msgid "SUN4U-8000-53.impact"
104msgstr "System performance may be affected."
105msgid "SUN4U-8000-53.action"
106msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>."
107#
108# code: SUN4U-8000-6H
109# keys: fault.cpu.ultraSPARC-III.l2cachedata
110#
111msgid "SUN4U-8000-6H.type"
112msgstr "Fault"
113msgid "SUN4U-8000-6H.severity"
114msgstr "Major"
115msgid "SUN4U-8000-6H.description"
116msgstr "The number of errors associated with this CPU has exceeded acceptable levels.  Refer to %s for more information."
117msgid "SUN4U-8000-6H.response"
118msgstr "The fault manager will attempt to remove the affected CPU from service."
119msgid "SUN4U-8000-6H.impact"
120msgstr "System performance may be affected."
121msgid "SUN4U-8000-6H.action"
122msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>."
123#
124# code: SUN4U-8000-7D
125# keys: fault.cpu.ultraSPARC-III.l2cachetag
126#
127msgid "SUN4U-8000-7D.type"
128msgstr "Fault"
129msgid "SUN4U-8000-7D.severity"
130msgstr "Major"
131msgid "SUN4U-8000-7D.description"
132msgstr "The number of errors associated with this CPU has exceeded acceptable levels.  Refer to %s for more information."
133msgid "SUN4U-8000-7D.response"
134msgstr "The fault manager will attempt to remove the affected CPU from service."
135msgid "SUN4U-8000-7D.impact"
136msgstr "System performance may be affected."
137msgid "SUN4U-8000-7D.action"
138msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>."
139#
140# code: SUN4U-8000-84
141# keys: fault.cpu.ultraSPARC-IIIi.dcache
142#
143msgid "SUN4U-8000-84.type"
144msgstr "Fault"
145msgid "SUN4U-8000-84.severity"
146msgstr "Major"
147msgid "SUN4U-8000-84.description"
148msgstr "The number of errors associated with this CPU has exceeded acceptable levels.  Refer to %s for more information."
149msgid "SUN4U-8000-84.response"
150msgstr "The fault manager will attempt to remove the affected CPU from service."
151msgid "SUN4U-8000-84.impact"
152msgstr "System performance system may be affected."
153msgid "SUN4U-8000-84.action"
154msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>."
155#
156# code: SUN4U-8000-9R
157# keys: fault.cpu.ultraSPARC-IIIi.icache
158#
159msgid "SUN4U-8000-9R.type"
160msgstr "Fault"
161msgid "SUN4U-8000-9R.severity"
162msgstr "Major"
163msgid "SUN4U-8000-9R.description"
164msgstr "The number of errors associated with this CPU has exceeded acceptable levels.  Refer to %s for more information."
165msgid "SUN4U-8000-9R.response"
166msgstr "The fault manager will attempt to remove the affected CPU from service."
167msgid "SUN4U-8000-9R.impact"
168msgstr "System performance may be affected."
169msgid "SUN4U-8000-9R.action"
170msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>."
171#
172# code: SUN4U-8000-AC
173# keys: fault.cpu.ultraSPARC-IIIi.l2cachedata
174#
175msgid "SUN4U-8000-AC.type"
176msgstr "Fault"
177msgid "SUN4U-8000-AC.severity"
178msgstr "Major"
179msgid "SUN4U-8000-AC.description"
180msgstr "The number of errors associated with this CPU has exceeded acceptable levels.  Refer to %s for more information."
181msgid "SUN4U-8000-AC.response"
182msgstr "The fault manager will attempt to remove the affected CPU from service."
183msgid "SUN4U-8000-AC.impact"
184msgstr "System performance may be affected."
185msgid "SUN4U-8000-AC.action"
186msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>."
187#
188# code: SUN4U-8000-CQ
189# keys: fault.cpu.ultraSPARC-IIIi.l2cachetag
190#
191msgid "SUN4U-8000-CQ.type"
192msgstr "Fault"
193msgid "SUN4U-8000-CQ.severity"
194msgstr "Major"
195msgid "SUN4U-8000-CQ.description"
196msgstr "The number of errors associated with this CPU has exceeded acceptable levels.  Refer to %s for more information."
197msgid "SUN4U-8000-CQ.response"
198msgstr "The fault manager will attempt to remove the affected CPU from service."
199msgid "SUN4U-8000-CQ.impact"
200msgstr "System performance may be affected."
201msgid "SUN4U-8000-CQ.action"
202msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>."
203#
204# code: SUN4U-8000-DE
205# keys: fault.cpu.ultraSPARC-IIIplus.dcache
206#
207msgid "SUN4U-8000-DE.type"
208msgstr "Fault"
209msgid "SUN4U-8000-DE.severity"
210msgstr "Major"
211msgid "SUN4U-8000-DE.description"
212msgstr "The number of errors associated with this CPU has exceeded acceptable levels.  Refer to %s for more information."
213msgid "SUN4U-8000-DE.response"
214msgstr "The fault manager will attempt to remove the affected CPU from service."
215msgid "SUN4U-8000-DE.impact"
216msgstr "System performance may be affected."
217msgid "SUN4U-8000-DE.action"
218msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>."
219#
220# code: SUN4U-8000-EJ
221# keys: fault.cpu.ultraSPARC-IIIplus.icache
222#
223msgid "SUN4U-8000-EJ.type"
224msgstr "Fault"
225msgid "SUN4U-8000-EJ.severity"
226msgstr "Major"
227msgid "SUN4U-8000-EJ.description"
228msgstr "The number of errors associated with this CPU has exceeded acceptable levels.  Refer to %s for more information."
229msgid "SUN4U-8000-EJ.response"
230msgstr "The fault manager will attempt to remove the affected CPU from service."
231msgid "SUN4U-8000-EJ.impact"
232msgstr "System performance may be affected."
233msgid "SUN4U-8000-EJ.action"
234msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>."
235#
236# code: SUN4U-8000-F2
237# keys: fault.cpu.ultraSPARC-IIIplus.l2cachedata
238#
239msgid "SUN4U-8000-F2.type"
240msgstr "Fault"
241msgid "SUN4U-8000-F2.severity"
242msgstr "Major"
243msgid "SUN4U-8000-F2.description"
244msgstr "The number of errors associated with this CPU has exceeded acceptable levels.  Refer to %s for more information."
245msgid "SUN4U-8000-F2.response"
246msgstr "The fault manager will attempt to remove the affected CPU from service."
247msgid "SUN4U-8000-F2.impact"
248msgstr "System performance may be affected."
249msgid "SUN4U-8000-F2.action"
250msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>."
251#
252# code: SUN4U-8000-GX
253# keys: fault.cpu.ultraSPARC-IIIplus.l2cachetag
254#
255msgid "SUN4U-8000-GX.type"
256msgstr "Fault"
257msgid "SUN4U-8000-GX.severity"
258msgstr "Major"
259msgid "SUN4U-8000-GX.description"
260msgstr "The number of errors associated with this CPU has exceeded acceptable levels.  Refer to %s for more information."
261msgid "SUN4U-8000-GX.response"
262msgstr "An attempt will be made to remove the affected CPU from service."
263msgid "SUN4U-8000-GX.impact"
264msgstr "System performance may be affected."
265msgid "SUN4U-8000-GX.action"
266msgstr "Schedule a repair procedure to replace the affected CPU. Use fmdump -v -u <EVENT_ID> to identify the CPU."
267#
268# code: SUN4U-8000-H5
269# keys: fault.cpu.ultraSPARC-IV.dcache
270#
271msgid "SUN4U-8000-H5.type"
272msgstr "Fault"
273msgid "SUN4U-8000-H5.severity"
274msgstr "Major"
275msgid "SUN4U-8000-H5.description"
276msgstr "The number of errors associated with this CPU has exceeded acceptable levels.  Refer to %s for more information."
277msgid "SUN4U-8000-H5.response"
278msgstr "The fault manager will attempt to remove the affected CPU from service."
279msgid "SUN4U-8000-H5.impact"
280msgstr "System performance may be affected."
281msgid "SUN4U-8000-H5.action"
282msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>."
283#
284# code: SUN4U-8000-JS
285# keys: fault.cpu.ultraSPARC-IV.icache
286#
287msgid "SUN4U-8000-JS.type"
288msgstr "Fault"
289msgid "SUN4U-8000-JS.severity"
290msgstr "Major"
291msgid "SUN4U-8000-JS.description"
292msgstr "The number of errors associated with this CPU has exceeded acceptable levels.  Refer to %s for more information."
293msgid "SUN4U-8000-JS.response"
294msgstr "The fault manager will attempt to remove the affected CPU from service."
295msgid "SUN4U-8000-JS.impact"
296msgstr "System performance may be affected."
297msgid "SUN4U-8000-JS.action"
298msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>."
299#
300# code: SUN4U-8000-KA
301# keys: fault.cpu.ultraSPARC-IV.l2cachedata
302#
303msgid "SUN4U-8000-KA.type"
304msgstr "Fault"
305msgid "SUN4U-8000-KA.severity"
306msgstr "Major"
307msgid "SUN4U-8000-KA.description"
308msgstr "The number of errors associated with this CPU has exceeded acceptable levels.  Refer to %s for more information."
309msgid "SUN4U-8000-KA.response"
310msgstr "The fault manager will attempt to remove the affected CPU from service."
311msgid "SUN4U-8000-KA.impact"
312msgstr "System performance may be affected."
313msgid "SUN4U-8000-KA.action"
314msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>."
315#
316# code: SUN4U-8000-LP
317# keys: fault.cpu.ultraSPARC-IV.l2cachetag
318#
319msgid "SUN4U-8000-LP.type"
320msgstr "Fault"
321msgid "SUN4U-8000-LP.severity"
322msgstr "Major"
323msgid "SUN4U-8000-LP.description"
324msgstr "The number of errors associated with this CPU has exceeded acceptable levels.  Refer to %s for more information."
325msgid "SUN4U-8000-LP.response"
326msgstr "The fault manager will attempt to remove the affected CPU from service."
327msgid "SUN4U-8000-LP.impact"
328msgstr "System performance may be affected."
329msgid "SUN4U-8000-LP.action"
330msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>."
331#
332# code: SUN4U-8000-MD
333# keys: fault.cpu.ultraSPARC-III.fpu
334#
335msgid "SUN4U-8000-MD.type"
336msgstr "Fault"
337msgid "SUN4U-8000-MD.severity"
338msgstr "Major"
339msgid "SUN4U-8000-MD.description"
340msgstr "A fault has been detected in the FPU of this CPU.  Refer to %s for more information."
341msgid "SUN4U-8000-MD.response"
342msgstr "The fault manager will attempt to remove the affected CPU from service."
343msgid "SUN4U-8000-MD.impact"
344msgstr "System performance may be affected."
345msgid "SUN4U-8000-MD.action"
346msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>."
347#
348# code: SUN4U-8000-NH
349# keys: fault.cpu.ultraSPARC-IIIi.fpu
350#
351msgid "SUN4U-8000-NH.type"
352msgstr "Fault"
353msgid "SUN4U-8000-NH.severity"
354msgstr "Major"
355msgid "SUN4U-8000-NH.description"
356msgstr "A fault has been detected in the FPU of this CPU.  Refer to %s for more information."
357msgid "SUN4U-8000-NH.response"
358msgstr "The fault manager will attempt to remove the affected CPU from service."
359msgid "SUN4U-8000-NH.impact"
360msgstr "System performance may be affected."
361msgid "SUN4U-8000-NH.action"
362msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>."
363#
364# code: SUN4U-8000-P3
365# keys: fault.cpu.ultraSPARC-IIIplus.fpu
366#
367msgid "SUN4U-8000-P3.type"
368msgstr "Fault"
369msgid "SUN4U-8000-P3.severity"
370msgstr "Major"
371msgid "SUN4U-8000-P3.description"
372msgstr "A fault has been detected in the FPU of this CPU.  Refer to %s for more information."
373msgid "SUN4U-8000-P3.response"
374msgstr "The fault manager will attempt to remove the affected CPU from service."
375msgid "SUN4U-8000-P3.impact"
376msgstr "System performance may be affected."
377msgid "SUN4U-8000-P3.action"
378msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>."
379#
380# code: SUN4U-8000-QY
381# keys: fault.cpu.ultraSPARC-IV.fpu
382#
383msgid "SUN4U-8000-QY.type"
384msgstr "Fault"
385msgid "SUN4U-8000-QY.severity"
386msgstr "Major"
387msgid "SUN4U-8000-QY.description"
388msgstr "A fault has been detected in the FPU of this CPU.  Refer to %s for more information."
389msgid "SUN4U-8000-QY.response"
390msgstr "The fault manager will attempt to remove the affected CPU from service."
391msgid "SUN4U-8000-QY.impact"
392msgstr "System performance may be affected."
393msgid "SUN4U-8000-QY.action"
394msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>."
395#
396# code: SUN4U-8000-RQ
397# keys: fault.cpu.ultraSPARC-IVplus.fpu
398#
399msgid "SUN4U-8000-RQ.type"
400msgstr "Fault"
401msgid "SUN4U-8000-RQ.severity"
402msgstr "Major"
403msgid "SUN4U-8000-RQ.description"
404msgstr "A fault has been detected in the FPU of this CPU.  Refer to %s for more information."
405msgid "SUN4U-8000-RQ.response"
406msgstr "The fault manager will attempt to remove the affected CPU from service."
407msgid "SUN4U-8000-RQ.impact"
408msgstr "System performance may be affected."
409msgid "SUN4U-8000-RQ.action"
410msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>."
411#
412# code: SUN4U-8000-SC
413# keys: fault.cpu.ultraSPARC-IVplus.dcache
414#
415msgid "SUN4U-8000-SC.type"
416msgstr "Fault"
417msgid "SUN4U-8000-SC.severity"
418msgstr "Major"
419msgid "SUN4U-8000-SC.description"
420msgstr "The number of errors associated with this CPU has exceeded acceptable levels.  Refer to %s for more information."
421msgid "SUN4U-8000-SC.response"
422msgstr "The fault manager will attempt to remove the affected CPU from service."
423msgid "SUN4U-8000-SC.impact"
424msgstr "System performance may be affected."
425msgid "SUN4U-8000-SC.action"
426msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>."
427#
428# code: SUN4U-8000-TR
429# keys: fault.cpu.ultraSPARC-IVplus.icache
430#
431msgid "SUN4U-8000-TR.type"
432msgstr "Fault"
433msgid "SUN4U-8000-TR.severity"
434msgstr "Major"
435msgid "SUN4U-8000-TR.description"
436msgstr "The number of errors associated with this CPU has exceeded acceptable levels.  Refer to %s for more information."
437msgid "SUN4U-8000-TR.response"
438msgstr "The fault manager will attempt to remove the affected CPU from service."
439msgid "SUN4U-8000-TR.impact"
440msgstr "System performance may be affected."
441msgid "SUN4U-8000-TR.action"
442msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>."
443#
444# code: SUN4U-8000-U4
445# keys: fault.cpu.ultraSPARC-IVplus.pcache
446#
447msgid "SUN4U-8000-U4.type"
448msgstr "Fault"
449msgid "SUN4U-8000-U4.severity"
450msgstr "Major"
451msgid "SUN4U-8000-U4.description"
452msgstr "The number of errors associated with this CPU has exceeded acceptable levels.  Refer to %s for more information."
453msgid "SUN4U-8000-U4.response"
454msgstr "The fault manager will attempt to remove the affected CPU from service."
455msgid "SUN4U-8000-U4.impact"
456msgstr "System performance may be affected."
457msgid "SUN4U-8000-U4.action"
458msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>."
459#
460# code: SUN4U-8000-VX
461# keys: fault.cpu.ultraSPARC-IVplus.dtlb
462#
463msgid "SUN4U-8000-VX.type"
464msgstr "Fault"
465msgid "SUN4U-8000-VX.severity"
466msgstr "Major"
467msgid "SUN4U-8000-VX.description"
468msgstr "The number of errors associated with this CPU has exceeded acceptable levels.  Refer to %s for more information."
469msgid "SUN4U-8000-VX.response"
470msgstr "The fault manager will attempt to remove the affected CPU from service."
471msgid "SUN4U-8000-VX.impact"
472msgstr "System performance may be affected."
473msgid "SUN4U-8000-VX.action"
474msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>."
475#
476# code: SUN4U-8000-W2
477# keys: fault.cpu.ultraSPARC-IVplus.itlb
478#
479msgid "SUN4U-8000-W2.type"
480msgstr "Fault"
481msgid "SUN4U-8000-W2.severity"
482msgstr "Major"
483msgid "SUN4U-8000-W2.description"
484msgstr "The number of errors associated with this CPU has exceeded acceptable levels.  Refer to %s for more information."
485msgid "SUN4U-8000-W2.response"
486msgstr "The fault manager will attempt to remove the affected CPU from service."
487msgid "SUN4U-8000-W2.impact"
488msgstr "System performance may be affected."
489msgid "SUN4U-8000-W2.action"
490msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>."
491#
492# code: SUN4U-8000-XJ
493# keys: fault.cpu.ultraSPARC-IVplus.l2cachedata
494#
495msgid "SUN4U-8000-XJ.type"
496msgstr "Fault"
497msgid "SUN4U-8000-XJ.severity"
498msgstr "Major"
499msgid "SUN4U-8000-XJ.description"
500msgstr "The number of errors associated with this CPU has exceeded acceptable levels.  Refer to %s for more information."
501msgid "SUN4U-8000-XJ.response"
502msgstr "The fault manager will attempt to remove the affected CPU from service."
503msgid "SUN4U-8000-XJ.impact"
504msgstr "System performance may be affected."
505msgid "SUN4U-8000-XJ.action"
506msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>."
507#
508# code: SUN4U-8000-YE
509# keys: fault.cpu.ultraSPARC-IVplus.l2cachetag
510#
511msgid "SUN4U-8000-YE.type"
512msgstr "Fault"
513msgid "SUN4U-8000-YE.severity"
514msgstr "Major"
515msgid "SUN4U-8000-YE.description"
516msgstr "The number of errors associated with this CPU has exceeded acceptable levels.  Refer to %s for more information."
517msgid "SUN4U-8000-YE.response"
518msgstr "The fault manager will attempt to remove the affected CPU from service."
519msgid "SUN4U-8000-YE.impact"
520msgstr "System performance may be affected."
521msgid "SUN4U-8000-YE.action"
522msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>."
523#
524# code: SUN4U-8001-0J
525# keys: fault.cpu.ultraSPARC-IVplus.l3cachedata
526#
527msgid "SUN4U-8001-0J.type"
528msgstr "Fault"
529msgid "SUN4U-8001-0J.severity"
530msgstr "Major"
531msgid "SUN4U-8001-0J.description"
532msgstr "The number of errors associated with this CPU has exceeded acceptable levels.  Refer to %s for more information."
533msgid "SUN4U-8001-0J.response"
534msgstr "The fault manager will attempt to remove the affected CPU from service."
535msgid "SUN4U-8001-0J.impact"
536msgstr "System performance may be affected."
537msgid "SUN4U-8001-0J.action"
538msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>."
539#
540# code: SUN4U-8001-1E
541# keys: fault.cpu.ultraSPARC-IVplus.l3cachetag
542#
543msgid "SUN4U-8001-1E.type"
544msgstr "Fault"
545msgid "SUN4U-8001-1E.severity"
546msgstr "Major"
547msgid "SUN4U-8001-1E.description"
548msgstr "The number of errors associated with this CPU has exceeded acceptable levels.  Refer to %s for more information."
549msgid "SUN4U-8001-1E.response"
550msgstr "The fault manager will attempt to remove the affected CPU from service."
551msgid "SUN4U-8001-1E.impact"
552msgstr "System performance may be affected."
553msgid "SUN4U-8001-1E.action"
554msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>."
555#
556# code: SUN4U-8001-2X
557# keys: defect.ultraSPARC-II.memory.nodiag
558#
559msgid "SUN4U-8001-2X.type"
560msgstr "Defect"
561msgid "SUN4U-8001-2X.severity"
562msgstr "Minor"
563msgid "SUN4U-8001-2X.description"
564msgstr "The Solaris Fault Manager received an event from the IO subsystem for which automated diagnosis software is currently unavailable.  Refer to %s for more information."
565msgid "SUN4U-8001-2X.response"
566msgstr "The error information has been saved for examination by Sun."
567msgid "SUN4U-8001-2X.impact"
568msgstr "The error log will need to be manually examined using fmdump(1M) in order to determine if any human response is required."
569msgid "SUN4U-8001-2X.action"
570msgstr "Use fmdump -ev -u <EVENT-ID> to view and record the undiagnosed errors."
571#
572# code: SUN4U-8001-32
573# keys: fault.memory.datapath
574#
575msgid "SUN4U-8001-32.type"
576msgstr "Fault"
577msgid "SUN4U-8001-32.severity"
578msgstr "Major"
579msgid "SUN4U-8001-32.description"
580msgstr "Errors have been detected on multiple memory modules, suggesting that a problem exists somewhere else in the system.  Refer to %s for more information."
581msgid "SUN4U-8001-32.response"
582msgstr "Error reports from the affected components will be logged for examination by Sun."
583msgid "SUN4U-8001-32.impact"
584msgstr "System performance and stability may be affected."
585msgid "SUN4U-8001-32.action"
586msgstr "Contact your service provider for further diagnosis."
587#
588# code: SUN4U-8001-4R
589# keys: fault.io.datapath
590#
591msgid "SUN4U-8001-4R.type"
592msgstr "Fault"
593msgid "SUN4U-8001-4R.severity"
594msgstr "Critical"
595msgid "SUN4U-8001-4R.description"
596msgstr "\nA problem was detected in a system core bus.\n  Refer to %s for more information."
597msgid "SUN4U-8001-4R.response"
598msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
599msgid "SUN4U-8001-4R.impact"
600msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
601msgid "SUN4U-8001-4R.action"
602msgstr "\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
603#
604# code: SUN4U-8001-54
605# keys: defect.io.pci.driver fault.io.datapath
606#
607msgid "SUN4U-8001-54.type"
608msgstr "Fault"
609msgid "SUN4U-8001-54.severity"
610msgstr "Critical"
611msgid "SUN4U-8001-54.description"
612msgstr "\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n  Refer to %s for more information."
613msgid "SUN4U-8001-54.response"
614msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
615msgid "SUN4U-8001-54.impact"
616msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
617msgid "SUN4U-8001-54.action"
618msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).  Schedule a repair of the most likely suspect \nlisted in the output.  If the most likely suspect is a package then run \npkgchk on the package(s).\n"
619#
620# code: SUN4U-8001-6Q
621# keys: fault.io.datapath fault.io.pci.bus
622#
623msgid "SUN4U-8001-6Q.type"
624msgstr "Fault"
625msgid "SUN4U-8001-6Q.severity"
626msgstr "Critical"
627msgid "SUN4U-8001-6Q.description"
628msgstr "\nA problem was detected in a system core bus.\n  Refer to %s for more information."
629msgid "SUN4U-8001-6Q.response"
630msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
631msgid "SUN4U-8001-6Q.impact"
632msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
633msgid "SUN4U-8001-6Q.action"
634msgstr "\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
635#
636# code: SUN4U-8001-7C
637# keys: defect.io.pci.driver fault.io.datapath fault.io.pci.bus
638#
639msgid "SUN4U-8001-7C.type"
640msgstr "Fault"
641msgid "SUN4U-8001-7C.severity"
642msgstr "Critical"
643msgid "SUN4U-8001-7C.description"
644msgstr "\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n  Refer to %s for more information."
645msgid "SUN4U-8001-7C.response"
646msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
647msgid "SUN4U-8001-7C.impact"
648msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
649msgid "SUN4U-8001-7C.action"
650msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).  Schedule a repair of the most likely suspect \nlisted in the output.  If the most likely suspect is a package then run \npkgchk on the package(s).\n"
651#
652# code: SUN4U-8001-83
653# keys: fault.io.datapath fault.io.pci.device
654#
655msgid "SUN4U-8001-83.type"
656msgstr "Fault"
657msgid "SUN4U-8001-83.severity"
658msgstr "Critical"
659msgid "SUN4U-8001-83.description"
660msgstr "\nA problem was detected in a system core bus.\n  Refer to %s for more information."
661msgid "SUN4U-8001-83.response"
662msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
663msgid "SUN4U-8001-83.impact"
664msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
665msgid "SUN4U-8001-83.action"
666msgstr "\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
667#
668# code: SUN4U-8001-9Y
669# keys: defect.io.pci.driver fault.io.datapath fault.io.pci.device
670#
671msgid "SUN4U-8001-9Y.type"
672msgstr "Fault"
673msgid "SUN4U-8001-9Y.severity"
674msgstr "Critical"
675msgid "SUN4U-8001-9Y.description"
676msgstr "\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n  Refer to %s for more information."
677msgid "SUN4U-8001-9Y.response"
678msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
679msgid "SUN4U-8001-9Y.impact"
680msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
681msgid "SUN4U-8001-9Y.action"
682msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).  Schedule a repair of the most likely suspect \nlisted in the output.  If the most likely suspect is a package then run \npkgchk on the package(s).\n"
683#
684# code: SUN4U-8001-AD
685# keys: fault.io.datapath fault.io.pci.bus fault.io.pci.device
686#
687msgid "SUN4U-8001-AD.type"
688msgstr "Fault"
689msgid "SUN4U-8001-AD.severity"
690msgstr "Critical"
691msgid "SUN4U-8001-AD.description"
692msgstr "\nA problem was detected in a system core bus.\n  Refer to %s for more information."
693msgid "SUN4U-8001-AD.response"
694msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
695msgid "SUN4U-8001-AD.impact"
696msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
697msgid "SUN4U-8001-AD.action"
698msgstr "\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
699#
700# code: SUN4U-8001-CH
701# keys: defect.io.pci.driver fault.io.datapath fault.io.pci.bus fault.io.pci.device
702#
703msgid "SUN4U-8001-CH.type"
704msgstr "Fault"
705msgid "SUN4U-8001-CH.severity"
706msgstr "Critical"
707msgid "SUN4U-8001-CH.description"
708msgstr "\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n  Refer to %s for more information."
709msgid "SUN4U-8001-CH.response"
710msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
711msgid "SUN4U-8001-CH.impact"
712msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
713msgid "SUN4U-8001-CH.action"
714msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).  Schedule a repair of the most likely suspect \nlisted in the output.  If the most likely suspect is a package then run \npkgchk on the package(s).\n"
715#
716# code: SUN4U-8001-DA
717# keys: fault.io.hbus
718#
719msgid "SUN4U-8001-DA.type"
720msgstr "Fault"
721msgid "SUN4U-8001-DA.severity"
722msgstr "Critical"
723msgid "SUN4U-8001-DA.description"
724msgstr "\nA problem was detected in a system core bus.\n  Refer to %s for more information."
725msgid "SUN4U-8001-DA.response"
726msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
727msgid "SUN4U-8001-DA.impact"
728msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
729msgid "SUN4U-8001-DA.action"
730msgstr "\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
731#
732# code: SUN4U-8001-EP
733# keys: defect.io.pci.driver fault.io.hbus
734#
735msgid "SUN4U-8001-EP.type"
736msgstr "Fault"
737msgid "SUN4U-8001-EP.severity"
738msgstr "Critical"
739msgid "SUN4U-8001-EP.description"
740msgstr "\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n  Refer to %s for more information."
741msgid "SUN4U-8001-EP.response"
742msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
743msgid "SUN4U-8001-EP.impact"
744msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
745msgid "SUN4U-8001-EP.action"
746msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).  Schedule a repair of the most likely suspect \nlisted in the output.  If the most likely suspect is a package then run \npkgchk on the package(s).\n"
747#
748# code: SUN4U-8001-F5
749# keys: fault.io.hbus fault.io.pci.bus
750#
751msgid "SUN4U-8001-F5.type"
752msgstr "Fault"
753msgid "SUN4U-8001-F5.severity"
754msgstr "Critical"
755msgid "SUN4U-8001-F5.description"
756msgstr "\nA problem was detected in a system core bus.\n  Refer to %s for more information."
757msgid "SUN4U-8001-F5.response"
758msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
759msgid "SUN4U-8001-F5.impact"
760msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
761msgid "SUN4U-8001-F5.action"
762msgstr "\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
763#
764# code: SUN4U-8001-GS
765# keys: defect.io.pci.driver fault.io.hbus fault.io.pci.bus
766#
767msgid "SUN4U-8001-GS.type"
768msgstr "Fault"
769msgid "SUN4U-8001-GS.severity"
770msgstr "Critical"
771msgid "SUN4U-8001-GS.description"
772msgstr "\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n  Refer to %s for more information."
773msgid "SUN4U-8001-GS.response"
774msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
775msgid "SUN4U-8001-GS.impact"
776msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
777msgid "SUN4U-8001-GS.action"
778msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).  Schedule a repair of the most likely suspect \nlisted in the output.  If the most likely suspect is a package then run \npkgchk on the package(s).\n"
779#
780# code: SUN4U-8001-H2
781# keys: fault.io.hbus fault.io.pci.device
782#
783msgid "SUN4U-8001-H2.type"
784msgstr "Fault"
785msgid "SUN4U-8001-H2.severity"
786msgstr "Critical"
787msgid "SUN4U-8001-H2.description"
788msgstr "\nA problem was detected in a system core bus.\n  Refer to %s for more information."
789msgid "SUN4U-8001-H2.response"
790msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
791msgid "SUN4U-8001-H2.impact"
792msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
793msgid "SUN4U-8001-H2.action"
794msgstr "\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
795#
796# code: SUN4U-8001-JX
797# keys: defect.io.pci.driver fault.io.hbus fault.io.pci.device
798#
799msgid "SUN4U-8001-JX.type"
800msgstr "Fault"
801msgid "SUN4U-8001-JX.severity"
802msgstr "Critical"
803msgid "SUN4U-8001-JX.description"
804msgstr "\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n  Refer to %s for more information."
805msgid "SUN4U-8001-JX.response"
806msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
807msgid "SUN4U-8001-JX.impact"
808msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
809msgid "SUN4U-8001-JX.action"
810msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).  Schedule a repair of the most likely suspect \nlisted in the output.  If the most likely suspect is a package then run \npkgchk on the package(s).\n"
811#
812# code: SUN4U-8001-KE
813# keys: fault.io.hbus fault.io.pci.bus fault.io.pci.device
814#
815msgid "SUN4U-8001-KE.type"
816msgstr "Fault"
817msgid "SUN4U-8001-KE.severity"
818msgstr "Critical"
819msgid "SUN4U-8001-KE.description"
820msgstr "\nA problem was detected in a system core bus.\n  Refer to %s for more information."
821msgid "SUN4U-8001-KE.response"
822msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
823msgid "SUN4U-8001-KE.impact"
824msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
825msgid "SUN4U-8001-KE.action"
826msgstr "\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
827#
828# code: SUN4U-8001-LJ
829# keys: defect.io.pci.driver fault.io.hbus fault.io.pci.bus fault.io.pci.device
830#
831msgid "SUN4U-8001-LJ.type"
832msgstr "Fault"
833msgid "SUN4U-8001-LJ.severity"
834msgstr "Critical"
835msgid "SUN4U-8001-LJ.description"
836msgstr "\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n  Refer to %s for more information."
837msgid "SUN4U-8001-LJ.response"
838msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
839msgid "SUN4U-8001-LJ.impact"
840msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
841msgid "SUN4U-8001-LJ.action"
842msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).  Schedule a repair of the most likely suspect \nlisted in the output.  If the most likely suspect is a package then run \npkgchk on the package(s).\n"
843#
844# code: SUN4U-8001-MC
845# keys: fault.io.datapath fault.io.hbus
846#
847msgid "SUN4U-8001-MC.type"
848msgstr "Fault"
849msgid "SUN4U-8001-MC.severity"
850msgstr "Critical"
851msgid "SUN4U-8001-MC.description"
852msgstr "\nA problem was detected in a system core bus.\n  Refer to %s for more information."
853msgid "SUN4U-8001-MC.response"
854msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
855msgid "SUN4U-8001-MC.impact"
856msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
857msgid "SUN4U-8001-MC.action"
858msgstr "\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
859#
860# code: SUN4U-8001-NQ
861# keys: defect.io.pci.driver fault.io.datapath fault.io.hbus
862#
863msgid "SUN4U-8001-NQ.type"
864msgstr "Fault"
865msgid "SUN4U-8001-NQ.severity"
866msgstr "Critical"
867msgid "SUN4U-8001-NQ.description"
868msgstr "\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n  Refer to %s for more information."
869msgid "SUN4U-8001-NQ.response"
870msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
871msgid "SUN4U-8001-NQ.impact"
872msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
873msgid "SUN4U-8001-NQ.action"
874msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).  Schedule a repair of the most likely suspect \nlisted in the output.  If the most likely suspect is a package then run \npkgchk on the package(s).\n"
875#
876# code: SUN4U-8001-P4
877# keys: fault.io.datapath fault.io.hbus fault.io.pci.bus
878#
879msgid "SUN4U-8001-P4.type"
880msgstr "Fault"
881msgid "SUN4U-8001-P4.severity"
882msgstr "Critical"
883msgid "SUN4U-8001-P4.description"
884msgstr "\nA problem was detected in a system core bus.\n  Refer to %s for more information."
885msgid "SUN4U-8001-P4.response"
886msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
887msgid "SUN4U-8001-P4.impact"
888msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
889msgid "SUN4U-8001-P4.action"
890msgstr "\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
891#
892# code: SUN4U-8001-QR
893# keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.pci.bus
894#
895msgid "SUN4U-8001-QR.type"
896msgstr "Fault"
897msgid "SUN4U-8001-QR.severity"
898msgstr "Critical"
899msgid "SUN4U-8001-QR.description"
900msgstr "\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n  Refer to %s for more information."
901msgid "SUN4U-8001-QR.response"
902msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
903msgid "SUN4U-8001-QR.impact"
904msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
905msgid "SUN4U-8001-QR.action"
906msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).  Schedule a repair of the most likely suspect \nlisted in the output.  If the most likely suspect is a package then run \npkgchk on the package(s).\n"
907#
908# code: SUN4U-8001-RH
909# keys: fault.io.datapath fault.io.hbus fault.io.pci.device
910#
911msgid "SUN4U-8001-RH.type"
912msgstr "Fault"
913msgid "SUN4U-8001-RH.severity"
914msgstr "Critical"
915msgid "SUN4U-8001-RH.description"
916msgstr "\nA problem was detected in a system core bus.\n  Refer to %s for more information."
917msgid "SUN4U-8001-RH.response"
918msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
919msgid "SUN4U-8001-RH.impact"
920msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
921msgid "SUN4U-8001-RH.action"
922msgstr "\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
923#
924# code: SUN4U-8001-SD
925# keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.pci.device
926#
927msgid "SUN4U-8001-SD.type"
928msgstr "Fault"
929msgid "SUN4U-8001-SD.severity"
930msgstr "Critical"
931msgid "SUN4U-8001-SD.description"
932msgstr "\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n  Refer to %s for more information."
933msgid "SUN4U-8001-SD.response"
934msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
935msgid "SUN4U-8001-SD.impact"
936msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
937msgid "SUN4U-8001-SD.action"
938msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).  Schedule a repair of the most likely suspect \nlisted in the output.  If the most likely suspect is a package then run \npkgchk on the package(s).\n"
939#
940# code: SUN4U-8001-TY
941# keys: fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.pci.device
942#
943msgid "SUN4U-8001-TY.type"
944msgstr "Fault"
945msgid "SUN4U-8001-TY.severity"
946msgstr "Critical"
947msgid "SUN4U-8001-TY.description"
948msgstr "\nA problem was detected in a system core bus.\n  Refer to %s for more information."
949msgid "SUN4U-8001-TY.response"
950msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
951msgid "SUN4U-8001-TY.impact"
952msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
953msgid "SUN4U-8001-TY.action"
954msgstr "\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
955#
956# code: SUN4U-8001-U3
957# keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.pci.device
958#
959msgid "SUN4U-8001-U3.type"
960msgstr "Fault"
961msgid "SUN4U-8001-U3.severity"
962msgstr "Critical"
963msgid "SUN4U-8001-U3.description"
964msgstr "\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n  Refer to %s for more information."
965msgid "SUN4U-8001-U3.response"
966msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
967msgid "SUN4U-8001-U3.impact"
968msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
969msgid "SUN4U-8001-U3.action"
970msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).  Schedule a repair of the most likely suspect \nlisted in the output.  If the most likely suspect is a package then run \npkgchk on the package(s).\n"
971#
972# code: SUN4U-8001-VS
973# keys: fault.io.schizo
974#
975msgid "SUN4U-8001-VS.type"
976msgstr "Fault"
977msgid "SUN4U-8001-VS.severity"
978msgstr "Critical"
979msgid "SUN4U-8001-VS.description"
980msgstr "\nA problem was detected in a system core bus.\n  Refer to %s for more information."
981msgid "SUN4U-8001-VS.response"
982msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
983msgid "SUN4U-8001-VS.impact"
984msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
985msgid "SUN4U-8001-VS.action"
986msgstr "\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
987#
988# code: SUN4U-8001-W5
989# keys: defect.io.pci.driver fault.io.schizo
990#
991msgid "SUN4U-8001-W5.type"
992msgstr "Fault"
993msgid "SUN4U-8001-W5.severity"
994msgstr "Critical"
995msgid "SUN4U-8001-W5.description"
996msgstr "\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n  Refer to %s for more information."
997msgid "SUN4U-8001-W5.response"
998msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
999msgid "SUN4U-8001-W5.impact"
1000msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
1001msgid "SUN4U-8001-W5.action"
1002msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).  Schedule a repair of the most likely suspect \nlisted in the output.  If the most likely suspect is a package then run \npkgchk on the package(s).\n"
1003#
1004# code: SUN4U-8001-XP
1005# keys: fault.io.pci.bus fault.io.schizo
1006#
1007msgid "SUN4U-8001-XP.type"
1008msgstr "Fault"
1009msgid "SUN4U-8001-XP.severity"
1010msgstr "Critical"
1011msgid "SUN4U-8001-XP.description"
1012msgstr "\nA problem was detected in a system core bus.\n  Refer to %s for more information."
1013msgid "SUN4U-8001-XP.response"
1014msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
1015msgid "SUN4U-8001-XP.impact"
1016msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
1017msgid "SUN4U-8001-XP.action"
1018msgstr "\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
1019#
1020# code: SUN4U-8001-YA
1021# keys: defect.io.pci.driver fault.io.pci.bus fault.io.schizo
1022#
1023msgid "SUN4U-8001-YA.type"
1024msgstr "Fault"
1025msgid "SUN4U-8001-YA.severity"
1026msgstr "Critical"
1027msgid "SUN4U-8001-YA.description"
1028msgstr "\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n  Refer to %s for more information."
1029msgid "SUN4U-8001-YA.response"
1030msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
1031msgid "SUN4U-8001-YA.impact"
1032msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
1033msgid "SUN4U-8001-YA.action"
1034msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).  Schedule a repair of the most likely suspect \nlisted in the output.  If the most likely suspect is a package then run \npkgchk on the package(s).\n"
1035#
1036# code: SUN4U-8002-0R
1037# keys: fault.io.pci.device fault.io.schizo
1038#
1039msgid "SUN4U-8002-0R.type"
1040msgstr "Fault"
1041msgid "SUN4U-8002-0R.severity"
1042msgstr "Critical"
1043msgid "SUN4U-8002-0R.description"
1044msgstr "\nA problem was detected in a system core bus.\n  Refer to %s for more information."
1045msgid "SUN4U-8002-0R.response"
1046msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
1047msgid "SUN4U-8002-0R.impact"
1048msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
1049msgid "SUN4U-8002-0R.action"
1050msgstr "\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
1051#
1052# code: SUN4U-8002-14
1053# keys: defect.io.pci.driver fault.io.pci.device fault.io.schizo
1054#
1055msgid "SUN4U-8002-14.type"
1056msgstr "Fault"
1057msgid "SUN4U-8002-14.severity"
1058msgstr "Critical"
1059msgid "SUN4U-8002-14.description"
1060msgstr "\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n  Refer to %s for more information."
1061msgid "SUN4U-8002-14.response"
1062msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
1063msgid "SUN4U-8002-14.impact"
1064msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
1065msgid "SUN4U-8002-14.action"
1066msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).  Schedule a repair of the most likely suspect \nlisted in the output.  If the most likely suspect is a package then run \npkgchk on the package(s).\n"
1067#
1068# code: SUN4U-8002-2Q
1069# keys: fault.io.pci.bus fault.io.pci.device fault.io.schizo
1070#
1071msgid "SUN4U-8002-2Q.type"
1072msgstr "Fault"
1073msgid "SUN4U-8002-2Q.severity"
1074msgstr "Critical"
1075msgid "SUN4U-8002-2Q.description"
1076msgstr "\nA problem was detected in a system core bus.\n  Refer to %s for more information."
1077msgid "SUN4U-8002-2Q.response"
1078msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
1079msgid "SUN4U-8002-2Q.impact"
1080msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
1081msgid "SUN4U-8002-2Q.action"
1082msgstr "\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
1083#
1084# code: SUN4U-8002-3C
1085# keys: defect.io.pci.driver fault.io.pci.bus fault.io.pci.device fault.io.schizo
1086#
1087msgid "SUN4U-8002-3C.type"
1088msgstr "Fault"
1089msgid "SUN4U-8002-3C.severity"
1090msgstr "Critical"
1091msgid "SUN4U-8002-3C.description"
1092msgstr "\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n  Refer to %s for more information."
1093msgid "SUN4U-8002-3C.response"
1094msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
1095msgid "SUN4U-8002-3C.impact"
1096msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
1097msgid "SUN4U-8002-3C.action"
1098msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).  Schedule a repair of the most likely suspect \nlisted in the output.  If the most likely suspect is a package then run \npkgchk on the package(s).\n"
1099#
1100# code: SUN4U-8002-4J
1101# keys: fault.io.datapath fault.io.schizo
1102#
1103msgid "SUN4U-8002-4J.type"
1104msgstr "Fault"
1105msgid "SUN4U-8002-4J.severity"
1106msgstr "Critical"
1107msgid "SUN4U-8002-4J.description"
1108msgstr "\nA problem was detected in a system core bus.\n  Refer to %s for more information."
1109msgid "SUN4U-8002-4J.response"
1110msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
1111msgid "SUN4U-8002-4J.impact"
1112msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
1113msgid "SUN4U-8002-4J.action"
1114msgstr "\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
1115#
1116# code: SUN4U-8002-5E
1117# keys: defect.io.pci.driver fault.io.datapath fault.io.schizo
1118#
1119msgid "SUN4U-8002-5E.type"
1120msgstr "Fault"
1121msgid "SUN4U-8002-5E.severity"
1122msgstr "Critical"
1123msgid "SUN4U-8002-5E.description"
1124msgstr "\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n  Refer to %s for more information."
1125msgid "SUN4U-8002-5E.response"
1126msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
1127msgid "SUN4U-8002-5E.impact"
1128msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
1129msgid "SUN4U-8002-5E.action"
1130msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).  Schedule a repair of the most likely suspect \nlisted in the output.  If the most likely suspect is a package then run \npkgchk on the package(s).\n"
1131#
1132# code: SUN4U-8002-6X
1133# keys: fault.io.datapath fault.io.pci.bus fault.io.schizo
1134#
1135msgid "SUN4U-8002-6X.type"
1136msgstr "Fault"
1137msgid "SUN4U-8002-6X.severity"
1138msgstr "Critical"
1139msgid "SUN4U-8002-6X.description"
1140msgstr "\nA problem was detected in a system core bus.\n  Refer to %s for more information."
1141msgid "SUN4U-8002-6X.response"
1142msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
1143msgid "SUN4U-8002-6X.impact"
1144msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
1145msgid "SUN4U-8002-6X.action"
1146msgstr "\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
1147#
1148# code: SUN4U-8002-72
1149# keys: defect.io.pci.driver fault.io.datapath fault.io.pci.bus fault.io.schizo
1150#
1151msgid "SUN4U-8002-72.type"
1152msgstr "Fault"
1153msgid "SUN4U-8002-72.severity"
1154msgstr "Critical"
1155msgid "SUN4U-8002-72.description"
1156msgstr "\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n  Refer to %s for more information."
1157msgid "SUN4U-8002-72.response"
1158msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
1159msgid "SUN4U-8002-72.impact"
1160msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
1161msgid "SUN4U-8002-72.action"
1162msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).  Schedule a repair of the most likely suspect \nlisted in the output.  If the most likely suspect is a package then run \npkgchk on the package(s).\n"
1163#
1164# code: SUN4U-8002-8A
1165# keys: fault.io.datapath fault.io.pci.device fault.io.schizo
1166#
1167msgid "SUN4U-8002-8A.type"
1168msgstr "Fault"
1169msgid "SUN4U-8002-8A.severity"
1170msgstr "Critical"
1171msgid "SUN4U-8002-8A.description"
1172msgstr "\nA problem was detected in a system core bus.\n  Refer to %s for more information."
1173msgid "SUN4U-8002-8A.response"
1174msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
1175msgid "SUN4U-8002-8A.impact"
1176msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
1177msgid "SUN4U-8002-8A.action"
1178msgstr "\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
1179#
1180# code: SUN4U-8002-9P
1181# keys: defect.io.pci.driver fault.io.datapath fault.io.pci.device fault.io.schizo
1182#
1183msgid "SUN4U-8002-9P.type"
1184msgstr "Fault"
1185msgid "SUN4U-8002-9P.severity"
1186msgstr "Critical"
1187msgid "SUN4U-8002-9P.description"
1188msgstr "\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n  Refer to %s for more information."
1189msgid "SUN4U-8002-9P.response"
1190msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
1191msgid "SUN4U-8002-9P.impact"
1192msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
1193msgid "SUN4U-8002-9P.action"
1194msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).  Schedule a repair of the most likely suspect \nlisted in the output.  If the most likely suspect is a package then run \npkgchk on the package(s).\n"
1195#
1196# code: SUN4U-8002-A5
1197# keys: fault.io.datapath fault.io.pci.bus fault.io.pci.device fault.io.schizo
1198#
1199msgid "SUN4U-8002-A5.type"
1200msgstr "Fault"
1201msgid "SUN4U-8002-A5.severity"
1202msgstr "Critical"
1203msgid "SUN4U-8002-A5.description"
1204msgstr "\nA problem was detected in a system core bus.\n  Refer to %s for more information."
1205msgid "SUN4U-8002-A5.response"
1206msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
1207msgid "SUN4U-8002-A5.impact"
1208msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
1209msgid "SUN4U-8002-A5.action"
1210msgstr "\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
1211#
1212# code: SUN4U-8002-CS
1213# keys: defect.io.pci.driver fault.io.datapath fault.io.pci.bus fault.io.pci.device fault.io.schizo
1214#
1215msgid "SUN4U-8002-CS.type"
1216msgstr "Fault"
1217msgid "SUN4U-8002-CS.severity"
1218msgstr "Critical"
1219msgid "SUN4U-8002-CS.description"
1220msgstr "\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n  Refer to %s for more information."
1221msgid "SUN4U-8002-CS.response"
1222msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
1223msgid "SUN4U-8002-CS.impact"
1224msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
1225msgid "SUN4U-8002-CS.action"
1226msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).  Schedule a repair of the most likely suspect \nlisted in the output.  If the most likely suspect is a package then run \npkgchk on the package(s).\n"
1227#
1228# code: SUN4U-8002-D3
1229# keys: fault.io.hbus fault.io.schizo
1230#
1231msgid "SUN4U-8002-D3.type"
1232msgstr "Fault"
1233msgid "SUN4U-8002-D3.severity"
1234msgstr "Critical"
1235msgid "SUN4U-8002-D3.description"
1236msgstr "\nA problem was detected in a system core bus.\n  Refer to %s for more information."
1237msgid "SUN4U-8002-D3.response"
1238msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
1239msgid "SUN4U-8002-D3.impact"
1240msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
1241msgid "SUN4U-8002-D3.action"
1242msgstr "\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
1243#
1244# code: SUN4U-8002-EY
1245# keys: defect.io.pci.driver fault.io.hbus fault.io.schizo
1246#
1247msgid "SUN4U-8002-EY.type"
1248msgstr "Fault"
1249msgid "SUN4U-8002-EY.severity"
1250msgstr "Critical"
1251msgid "SUN4U-8002-EY.description"
1252msgstr "\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n  Refer to %s for more information."
1253msgid "SUN4U-8002-EY.response"
1254msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
1255msgid "SUN4U-8002-EY.impact"
1256msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
1257msgid "SUN4U-8002-EY.action"
1258msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).  Schedule a repair of the most likely suspect \nlisted in the output.  If the most likely suspect is a package then run \npkgchk on the package(s).\n"
1259#
1260# code: SUN4U-8002-FD
1261# keys: fault.io.hbus fault.io.pci.bus fault.io.schizo
1262#
1263msgid "SUN4U-8002-FD.type"
1264msgstr "Fault"
1265msgid "SUN4U-8002-FD.severity"
1266msgstr "Critical"
1267msgid "SUN4U-8002-FD.description"
1268msgstr "\nA problem was detected in a system core bus.\n  Refer to %s for more information."
1269msgid "SUN4U-8002-FD.response"
1270msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
1271msgid "SUN4U-8002-FD.impact"
1272msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
1273msgid "SUN4U-8002-FD.action"
1274msgstr "\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
1275#
1276# code: SUN4U-8002-GH
1277# keys: defect.io.pci.driver fault.io.hbus fault.io.pci.bus fault.io.schizo
1278#
1279msgid "SUN4U-8002-GH.type"
1280msgstr "Fault"
1281msgid "SUN4U-8002-GH.severity"
1282msgstr "Critical"
1283msgid "SUN4U-8002-GH.description"
1284msgstr "\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n  Refer to %s for more information."
1285msgid "SUN4U-8002-GH.response"
1286msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
1287msgid "SUN4U-8002-GH.impact"
1288msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
1289msgid "SUN4U-8002-GH.action"
1290msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).  Schedule a repair of the most likely suspect \nlisted in the output.  If the most likely suspect is a package then run \npkgchk on the package(s).\n"
1291#
1292# code: SUN4U-8002-HC
1293# keys: fault.io.hbus fault.io.pci.device fault.io.schizo
1294#
1295msgid "SUN4U-8002-HC.type"
1296msgstr "Fault"
1297msgid "SUN4U-8002-HC.severity"
1298msgstr "Critical"
1299msgid "SUN4U-8002-HC.description"
1300msgstr "\nA problem was detected in a system core bus.\n  Refer to %s for more information."
1301msgid "SUN4U-8002-HC.response"
1302msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
1303msgid "SUN4U-8002-HC.impact"
1304msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
1305msgid "SUN4U-8002-HC.action"
1306msgstr "\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
1307#
1308# code: SUN4U-8002-JQ
1309# keys: defect.io.pci.driver fault.io.hbus fault.io.pci.device fault.io.schizo
1310#
1311msgid "SUN4U-8002-JQ.type"
1312msgstr "Fault"
1313msgid "SUN4U-8002-JQ.severity"
1314msgstr "Critical"
1315msgid "SUN4U-8002-JQ.description"
1316msgstr "\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n  Refer to %s for more information."
1317msgid "SUN4U-8002-JQ.response"
1318msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
1319msgid "SUN4U-8002-JQ.impact"
1320msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
1321msgid "SUN4U-8002-JQ.action"
1322msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).  Schedule a repair of the most likely suspect \nlisted in the output.  If the most likely suspect is a package then run \npkgchk on the package(s).\n"
1323#
1324# code: SUN4U-8002-K4
1325# keys: fault.io.hbus fault.io.pci.bus fault.io.pci.device fault.io.schizo
1326#
1327msgid "SUN4U-8002-K4.type"
1328msgstr "Fault"
1329msgid "SUN4U-8002-K4.severity"
1330msgstr "Critical"
1331msgid "SUN4U-8002-K4.description"
1332msgstr "\nA problem was detected in a system core bus.\n  Refer to %s for more information."
1333msgid "SUN4U-8002-K4.response"
1334msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
1335msgid "SUN4U-8002-K4.impact"
1336msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
1337msgid "SUN4U-8002-K4.action"
1338msgstr "\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
1339#
1340# code: SUN4U-8002-LR
1341# keys: defect.io.pci.driver fault.io.hbus fault.io.pci.bus fault.io.pci.device fault.io.schizo
1342#
1343msgid "SUN4U-8002-LR.type"
1344msgstr "Fault"
1345msgid "SUN4U-8002-LR.severity"
1346msgstr "Critical"
1347msgid "SUN4U-8002-LR.description"
1348msgstr "\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n  Refer to %s for more information."
1349msgid "SUN4U-8002-LR.response"
1350msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
1351msgid "SUN4U-8002-LR.impact"
1352msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
1353msgid "SUN4U-8002-LR.action"
1354msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).  Schedule a repair of the most likely suspect \nlisted in the output.  If the most likely suspect is a package then run \npkgchk on the package(s).\n"
1355#
1356# code: SUN4U-8002-M2
1357# keys: fault.io.datapath fault.io.hbus fault.io.schizo
1358#
1359msgid "SUN4U-8002-M2.type"
1360msgstr "Fault"
1361msgid "SUN4U-8002-M2.severity"
1362msgstr "Critical"
1363msgid "SUN4U-8002-M2.description"
1364msgstr "\nA problem was detected in a system core bus.\n  Refer to %s for more information."
1365msgid "SUN4U-8002-M2.response"
1366msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
1367msgid "SUN4U-8002-M2.impact"
1368msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
1369msgid "SUN4U-8002-M2.action"
1370msgstr "\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
1371#
1372# code: SUN4U-8002-NX
1373# keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.schizo
1374#
1375msgid "SUN4U-8002-NX.type"
1376msgstr "Fault"
1377msgid "SUN4U-8002-NX.severity"
1378msgstr "Critical"
1379msgid "SUN4U-8002-NX.description"
1380msgstr "\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n  Refer to %s for more information."
1381msgid "SUN4U-8002-NX.response"
1382msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
1383msgid "SUN4U-8002-NX.impact"
1384msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
1385msgid "SUN4U-8002-NX.action"
1386msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).  Schedule a repair of the most likely suspect \nlisted in the output.  If the most likely suspect is a package then run \npkgchk on the package(s).\n"
1387#
1388# code: SUN4U-8002-PE
1389# keys: fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.schizo
1390#
1391msgid "SUN4U-8002-PE.type"
1392msgstr "Fault"
1393msgid "SUN4U-8002-PE.severity"
1394msgstr "Critical"
1395msgid "SUN4U-8002-PE.description"
1396msgstr "\nA problem was detected in a system core bus.\n  Refer to %s for more information."
1397msgid "SUN4U-8002-PE.response"
1398msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
1399msgid "SUN4U-8002-PE.impact"
1400msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
1401msgid "SUN4U-8002-PE.action"
1402msgstr "\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
1403#
1404# code: SUN4U-8002-QJ
1405# keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.schizo
1406#
1407msgid "SUN4U-8002-QJ.type"
1408msgstr "Fault"
1409msgid "SUN4U-8002-QJ.severity"
1410msgstr "Critical"
1411msgid "SUN4U-8002-QJ.description"
1412msgstr "\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n  Refer to %s for more information."
1413msgid "SUN4U-8002-QJ.response"
1414msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
1415msgid "SUN4U-8002-QJ.impact"
1416msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
1417msgid "SUN4U-8002-QJ.action"
1418msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).  Schedule a repair of the most likely suspect \nlisted in the output.  If the most likely suspect is a package then run \npkgchk on the package(s).\n"
1419#
1420# code: SUN4U-8002-RS
1421# keys: fault.io.datapath fault.io.hbus fault.io.pci.device fault.io.schizo
1422#
1423msgid "SUN4U-8002-RS.type"
1424msgstr "Fault"
1425msgid "SUN4U-8002-RS.severity"
1426msgstr "Critical"
1427msgid "SUN4U-8002-RS.description"
1428msgstr "\nA problem was detected in a system core bus.\n  Refer to %s for more information."
1429msgid "SUN4U-8002-RS.response"
1430msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
1431msgid "SUN4U-8002-RS.impact"
1432msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
1433msgid "SUN4U-8002-RS.action"
1434msgstr "\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
1435#
1436# code: SUN4U-8002-S5
1437# keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.pci.device fault.io.schizo
1438#
1439msgid "SUN4U-8002-S5.type"
1440msgstr "Fault"
1441msgid "SUN4U-8002-S5.severity"
1442msgstr "Critical"
1443msgid "SUN4U-8002-S5.description"
1444msgstr "\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n  Refer to %s for more information."
1445msgid "SUN4U-8002-S5.response"
1446msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
1447msgid "SUN4U-8002-S5.impact"
1448msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
1449msgid "SUN4U-8002-S5.action"
1450msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).  Schedule a repair of the most likely suspect \nlisted in the output.  If the most likely suspect is a package then run \npkgchk on the package(s).\n"
1451#
1452# code: SUN4U-8002-TP
1453# keys: fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.pci.device fault.io.schizo
1454#
1455msgid "SUN4U-8002-TP.type"
1456msgstr "Fault"
1457msgid "SUN4U-8002-TP.severity"
1458msgstr "Critical"
1459msgid "SUN4U-8002-TP.description"
1460msgstr "\nA problem was detected in a system core bus.\n  Refer to %s for more information."
1461msgid "SUN4U-8002-TP.response"
1462msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
1463msgid "SUN4U-8002-TP.impact"
1464msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
1465msgid "SUN4U-8002-TP.action"
1466msgstr "\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
1467#
1468# code: SUN4U-8002-UA
1469# keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.pci.device fault.io.schizo
1470#
1471msgid "SUN4U-8002-UA.type"
1472msgstr "Fault"
1473msgid "SUN4U-8002-UA.severity"
1474msgstr "Critical"
1475msgid "SUN4U-8002-UA.description"
1476msgstr "\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n  Refer to %s for more information."
1477msgid "SUN4U-8002-UA.response"
1478msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
1479msgid "SUN4U-8002-UA.impact"
1480msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
1481msgid "SUN4U-8002-UA.action"
1482msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).  Schedule a repair of the most likely suspect \nlisted in the output.  If the most likely suspect is a package then run \npkgchk on the package(s).\n"
1483#
1484# code: SUN4U-8002-VH
1485# keys: fault.io.xmits
1486#
1487msgid "SUN4U-8002-VH.type"
1488msgstr "Fault"
1489msgid "SUN4U-8002-VH.severity"
1490msgstr "Critical"
1491msgid "SUN4U-8002-VH.description"
1492msgstr "\nA problem was detected in a system core bus.\n  Refer to %s for more information."
1493msgid "SUN4U-8002-VH.response"
1494msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
1495msgid "SUN4U-8002-VH.impact"
1496msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
1497msgid "SUN4U-8002-VH.action"
1498msgstr "\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
1499#
1500# code: SUN4U-8002-WD
1501# keys: defect.io.pci.driver fault.io.xmits
1502#
1503msgid "SUN4U-8002-WD.type"
1504msgstr "Fault"
1505msgid "SUN4U-8002-WD.severity"
1506msgstr "Critical"
1507msgid "SUN4U-8002-WD.description"
1508msgstr "\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n  Refer to %s for more information."
1509msgid "SUN4U-8002-WD.response"
1510msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
1511msgid "SUN4U-8002-WD.impact"
1512msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
1513msgid "SUN4U-8002-WD.action"
1514msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).  Schedule a repair of the most likely suspect \nlisted in the output.  If the most likely suspect is a package then run \npkgchk on the package(s).\n"
1515#
1516# code: SUN4U-8002-XY
1517# keys: fault.io.pci.bus fault.io.xmits
1518#
1519msgid "SUN4U-8002-XY.type"
1520msgstr "Fault"
1521msgid "SUN4U-8002-XY.severity"
1522msgstr "Critical"
1523msgid "SUN4U-8002-XY.description"
1524msgstr "\nA problem was detected in a system core bus.\n  Refer to %s for more information."
1525msgid "SUN4U-8002-XY.response"
1526msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
1527msgid "SUN4U-8002-XY.impact"
1528msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
1529msgid "SUN4U-8002-XY.action"
1530msgstr "\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
1531#
1532# code: SUN4U-8002-Y3
1533# keys: defect.io.pci.driver fault.io.pci.bus fault.io.xmits
1534#
1535msgid "SUN4U-8002-Y3.type"
1536msgstr "Fault"
1537msgid "SUN4U-8002-Y3.severity"
1538msgstr "Critical"
1539msgid "SUN4U-8002-Y3.description"
1540msgstr "\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n  Refer to %s for more information."
1541msgid "SUN4U-8002-Y3.response"
1542msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
1543msgid "SUN4U-8002-Y3.impact"
1544msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
1545msgid "SUN4U-8002-Y3.action"
1546msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).  Schedule a repair of the most likely suspect \nlisted in the output.  If the most likely suspect is a package then run \npkgchk on the package(s).\n"
1547#
1548# code: SUN4U-8003-0Y
1549# keys: fault.io.pci.device fault.io.xmits
1550#
1551msgid "SUN4U-8003-0Y.type"
1552msgstr "Fault"
1553msgid "SUN4U-8003-0Y.severity"
1554msgstr "Critical"
1555msgid "SUN4U-8003-0Y.description"
1556msgstr "\nA problem was detected in a system core bus.\n  Refer to %s for more information."
1557msgid "SUN4U-8003-0Y.response"
1558msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
1559msgid "SUN4U-8003-0Y.impact"
1560msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
1561msgid "SUN4U-8003-0Y.action"
1562msgstr "\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
1563#
1564# code: SUN4U-8003-13
1565# keys: defect.io.pci.driver fault.io.pci.device fault.io.xmits
1566#
1567msgid "SUN4U-8003-13.type"
1568msgstr "Fault"
1569msgid "SUN4U-8003-13.severity"
1570msgstr "Critical"
1571msgid "SUN4U-8003-13.description"
1572msgstr "\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n  Refer to %s for more information."
1573msgid "SUN4U-8003-13.response"
1574msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
1575msgid "SUN4U-8003-13.impact"
1576msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
1577msgid "SUN4U-8003-13.action"
1578msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).  Schedule a repair of the most likely suspect \nlisted in the output.  If the most likely suspect is a package then run \npkgchk on the package(s).\n"
1579#
1580# code: SUN4U-8003-2H
1581# keys: fault.io.pci.bus fault.io.pci.device fault.io.xmits
1582#
1583msgid "SUN4U-8003-2H.type"
1584msgstr "Fault"
1585msgid "SUN4U-8003-2H.severity"
1586msgstr "Critical"
1587msgid "SUN4U-8003-2H.description"
1588msgstr "\nA problem was detected in a system core bus.\n  Refer to %s for more information."
1589msgid "SUN4U-8003-2H.response"
1590msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
1591msgid "SUN4U-8003-2H.impact"
1592msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
1593msgid "SUN4U-8003-2H.action"
1594msgstr "\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
1595#
1596# code: SUN4U-8003-3D
1597# keys: defect.io.pci.driver fault.io.pci.bus fault.io.pci.device fault.io.xmits
1598#
1599msgid "SUN4U-8003-3D.type"
1600msgstr "Fault"
1601msgid "SUN4U-8003-3D.severity"
1602msgstr "Critical"
1603msgid "SUN4U-8003-3D.description"
1604msgstr "\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n  Refer to %s for more information."
1605msgid "SUN4U-8003-3D.response"
1606msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
1607msgid "SUN4U-8003-3D.impact"
1608msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
1609msgid "SUN4U-8003-3D.action"
1610msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).  Schedule a repair of the most likely suspect \nlisted in the output.  If the most likely suspect is a package then run \npkgchk on the package(s).\n"
1611#
1612# code: SUN4U-8003-4P
1613# keys: fault.io.datapath fault.io.xmits
1614#
1615msgid "SUN4U-8003-4P.type"
1616msgstr "Fault"
1617msgid "SUN4U-8003-4P.severity"
1618msgstr "Critical"
1619msgid "SUN4U-8003-4P.description"
1620msgstr "\nA problem was detected in a system core bus.\n  Refer to %s for more information."
1621msgid "SUN4U-8003-4P.response"
1622msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
1623msgid "SUN4U-8003-4P.impact"
1624msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
1625msgid "SUN4U-8003-4P.action"
1626msgstr "\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
1627#
1628# code: SUN4U-8003-5A
1629# keys: defect.io.pci.driver fault.io.datapath fault.io.xmits
1630#
1631msgid "SUN4U-8003-5A.type"
1632msgstr "Fault"
1633msgid "SUN4U-8003-5A.severity"
1634msgstr "Critical"
1635msgid "SUN4U-8003-5A.description"
1636msgstr "\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n  Refer to %s for more information."
1637msgid "SUN4U-8003-5A.response"
1638msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
1639msgid "SUN4U-8003-5A.impact"
1640msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
1641msgid "SUN4U-8003-5A.action"
1642msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).  Schedule a repair of the most likely suspect \nlisted in the output.  If the most likely suspect is a package then run \npkgchk on the package(s).\n"
1643#
1644# code: SUN4U-8003-6S
1645# keys: fault.io.datapath fault.io.pci.bus fault.io.xmits
1646#
1647msgid "SUN4U-8003-6S.type"
1648msgstr "Fault"
1649msgid "SUN4U-8003-6S.severity"
1650msgstr "Critical"
1651msgid "SUN4U-8003-6S.description"
1652msgstr "\nA problem was detected in a system core bus.\n  Refer to %s for more information."
1653msgid "SUN4U-8003-6S.response"
1654msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
1655msgid "SUN4U-8003-6S.impact"
1656msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
1657msgid "SUN4U-8003-6S.action"
1658msgstr "\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
1659#
1660# code: SUN4U-8003-75
1661# keys: defect.io.pci.driver fault.io.datapath fault.io.pci.bus fault.io.xmits
1662#
1663msgid "SUN4U-8003-75.type"
1664msgstr "Fault"
1665msgid "SUN4U-8003-75.severity"
1666msgstr "Critical"
1667msgid "SUN4U-8003-75.description"
1668msgstr "\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n  Refer to %s for more information."
1669msgid "SUN4U-8003-75.response"
1670msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
1671msgid "SUN4U-8003-75.impact"
1672msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
1673msgid "SUN4U-8003-75.action"
1674msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).  Schedule a repair of the most likely suspect \nlisted in the output.  If the most likely suspect is a package then run \npkgchk on the package(s).\n"
1675#
1676# code: SUN4U-8003-8E
1677# keys: fault.io.datapath fault.io.pci.device fault.io.xmits
1678#
1679msgid "SUN4U-8003-8E.type"
1680msgstr "Fault"
1681msgid "SUN4U-8003-8E.severity"
1682msgstr "Critical"
1683msgid "SUN4U-8003-8E.description"
1684msgstr "\nA problem was detected in a system core bus.\n  Refer to %s for more information."
1685msgid "SUN4U-8003-8E.response"
1686msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
1687msgid "SUN4U-8003-8E.impact"
1688msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
1689msgid "SUN4U-8003-8E.action"
1690msgstr "\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
1691#
1692# code: SUN4U-8003-9J
1693# keys: defect.io.pci.driver fault.io.datapath fault.io.pci.device fault.io.xmits
1694#
1695msgid "SUN4U-8003-9J.type"
1696msgstr "Fault"
1697msgid "SUN4U-8003-9J.severity"
1698msgstr "Critical"
1699msgid "SUN4U-8003-9J.description"
1700msgstr "\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n  Refer to %s for more information."
1701msgid "SUN4U-8003-9J.response"
1702msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
1703msgid "SUN4U-8003-9J.impact"
1704msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
1705msgid "SUN4U-8003-9J.action"
1706msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).  Schedule a repair of the most likely suspect \nlisted in the output.  If the most likely suspect is a package then run \npkgchk on the package(s).\n"
1707#
1708# code: SUN4U-8003-A2
1709# keys: fault.io.datapath fault.io.pci.bus fault.io.pci.device fault.io.xmits
1710#
1711msgid "SUN4U-8003-A2.type"
1712msgstr "Fault"
1713msgid "SUN4U-8003-A2.severity"
1714msgstr "Critical"
1715msgid "SUN4U-8003-A2.description"
1716msgstr "\nA problem was detected in a system core bus.\n  Refer to %s for more information."
1717msgid "SUN4U-8003-A2.response"
1718msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
1719msgid "SUN4U-8003-A2.impact"
1720msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
1721msgid "SUN4U-8003-A2.action"
1722msgstr "\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
1723#
1724# code: SUN4U-8003-CX
1725# keys: defect.io.pci.driver fault.io.datapath fault.io.pci.bus fault.io.pci.device fault.io.xmits
1726#
1727msgid "SUN4U-8003-CX.type"
1728msgstr "Fault"
1729msgid "SUN4U-8003-CX.severity"
1730msgstr "Critical"
1731msgid "SUN4U-8003-CX.description"
1732msgstr "\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n  Refer to %s for more information."
1733msgid "SUN4U-8003-CX.response"
1734msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
1735msgid "SUN4U-8003-CX.impact"
1736msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
1737msgid "SUN4U-8003-CX.action"
1738msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).  Schedule a repair of the most likely suspect \nlisted in the output.  If the most likely suspect is a package then run \npkgchk on the package(s).\n"
1739#
1740# code: SUN4U-8003-D4
1741# keys: fault.io.hbus fault.io.xmits
1742#
1743msgid "SUN4U-8003-D4.type"
1744msgstr "Fault"
1745msgid "SUN4U-8003-D4.severity"
1746msgstr "Critical"
1747msgid "SUN4U-8003-D4.description"
1748msgstr "\nA problem was detected in a system core bus.\n  Refer to %s for more information."
1749msgid "SUN4U-8003-D4.response"
1750msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
1751msgid "SUN4U-8003-D4.impact"
1752msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
1753msgid "SUN4U-8003-D4.action"
1754msgstr "\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
1755#
1756# code: SUN4U-8003-ER
1757# keys: defect.io.pci.driver fault.io.hbus fault.io.xmits
1758#
1759msgid "SUN4U-8003-ER.type"
1760msgstr "Fault"
1761msgid "SUN4U-8003-ER.severity"
1762msgstr "Critical"
1763msgid "SUN4U-8003-ER.description"
1764msgstr "\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n  Refer to %s for more information."
1765msgid "SUN4U-8003-ER.response"
1766msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
1767msgid "SUN4U-8003-ER.impact"
1768msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
1769msgid "SUN4U-8003-ER.action"
1770msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).  Schedule a repair of the most likely suspect \nlisted in the output.  If the most likely suspect is a package then run \npkgchk on the package(s).\n"
1771#
1772# code: SUN4U-8003-FC
1773# keys: fault.io.hbus fault.io.pci.bus fault.io.xmits
1774#
1775msgid "SUN4U-8003-FC.type"
1776msgstr "Fault"
1777msgid "SUN4U-8003-FC.severity"
1778msgstr "Critical"
1779msgid "SUN4U-8003-FC.description"
1780msgstr "\nA problem was detected in a system core bus.\n  Refer to %s for more information."
1781msgid "SUN4U-8003-FC.response"
1782msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
1783msgid "SUN4U-8003-FC.impact"
1784msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
1785msgid "SUN4U-8003-FC.action"
1786msgstr "\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
1787#
1788# code: SUN4U-8003-GQ
1789# keys: defect.io.pci.driver fault.io.hbus fault.io.pci.bus fault.io.xmits
1790#
1791msgid "SUN4U-8003-GQ.type"
1792msgstr "Fault"
1793msgid "SUN4U-8003-GQ.severity"
1794msgstr "Critical"
1795msgid "SUN4U-8003-GQ.description"
1796msgstr "\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n  Refer to %s for more information."
1797msgid "SUN4U-8003-GQ.response"
1798msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
1799msgid "SUN4U-8003-GQ.impact"
1800msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
1801msgid "SUN4U-8003-GQ.action"
1802msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).  Schedule a repair of the most likely suspect \nlisted in the output.  If the most likely suspect is a package then run \npkgchk on the package(s).\n"
1803#
1804# code: SUN4U-8003-HD
1805# keys: fault.io.hbus fault.io.pci.device fault.io.xmits
1806#
1807msgid "SUN4U-8003-HD.type"
1808msgstr "Fault"
1809msgid "SUN4U-8003-HD.severity"
1810msgstr "Critical"
1811msgid "SUN4U-8003-HD.description"
1812msgstr "\nA problem was detected in a system core bus.\n  Refer to %s for more information."
1813msgid "SUN4U-8003-HD.response"
1814msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
1815msgid "SUN4U-8003-HD.impact"
1816msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
1817msgid "SUN4U-8003-HD.action"
1818msgstr "\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
1819#
1820# code: SUN4U-8003-JH
1821# keys: defect.io.pci.driver fault.io.hbus fault.io.pci.device fault.io.xmits
1822#
1823msgid "SUN4U-8003-JH.type"
1824msgstr "Fault"
1825msgid "SUN4U-8003-JH.severity"
1826msgstr "Critical"
1827msgid "SUN4U-8003-JH.description"
1828msgstr "\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n  Refer to %s for more information."
1829msgid "SUN4U-8003-JH.response"
1830msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
1831msgid "SUN4U-8003-JH.impact"
1832msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
1833msgid "SUN4U-8003-JH.action"
1834msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).  Schedule a repair of the most likely suspect \nlisted in the output.  If the most likely suspect is a package then run \npkgchk on the package(s).\n"
1835#
1836# code: SUN4U-8003-K3
1837# keys: fault.io.hbus fault.io.pci.bus fault.io.pci.device fault.io.xmits
1838#
1839msgid "SUN4U-8003-K3.type"
1840msgstr "Fault"
1841msgid "SUN4U-8003-K3.severity"
1842msgstr "Critical"
1843msgid "SUN4U-8003-K3.description"
1844msgstr "\nA problem was detected in a system core bus.\n  Refer to %s for more information."
1845msgid "SUN4U-8003-K3.response"
1846msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
1847msgid "SUN4U-8003-K3.impact"
1848msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
1849msgid "SUN4U-8003-K3.action"
1850msgstr "\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
1851#
1852# code: SUN4U-8003-LY
1853# keys: defect.io.pci.driver fault.io.hbus fault.io.pci.bus fault.io.pci.device fault.io.xmits
1854#
1855msgid "SUN4U-8003-LY.type"
1856msgstr "Fault"
1857msgid "SUN4U-8003-LY.severity"
1858msgstr "Critical"
1859msgid "SUN4U-8003-LY.description"
1860msgstr "\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n  Refer to %s for more information."
1861msgid "SUN4U-8003-LY.response"
1862msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
1863msgid "SUN4U-8003-LY.impact"
1864msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
1865msgid "SUN4U-8003-LY.action"
1866msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).  Schedule a repair of the most likely suspect \nlisted in the output.  If the most likely suspect is a package then run \npkgchk on the package(s).\n"
1867#
1868# code: SUN4U-8003-M5
1869# keys: fault.io.datapath fault.io.hbus fault.io.xmits
1870#
1871msgid "SUN4U-8003-M5.type"
1872msgstr "Fault"
1873msgid "SUN4U-8003-M5.severity"
1874msgstr "Critical"
1875msgid "SUN4U-8003-M5.description"
1876msgstr "\nA problem was detected in a system core bus.\n  Refer to %s for more information."
1877msgid "SUN4U-8003-M5.response"
1878msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
1879msgid "SUN4U-8003-M5.impact"
1880msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
1881msgid "SUN4U-8003-M5.action"
1882msgstr "\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
1883#
1884# code: SUN4U-8003-NS
1885# keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.xmits
1886#
1887msgid "SUN4U-8003-NS.type"
1888msgstr "Fault"
1889msgid "SUN4U-8003-NS.severity"
1890msgstr "Critical"
1891msgid "SUN4U-8003-NS.description"
1892msgstr "\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n  Refer to %s for more information."
1893msgid "SUN4U-8003-NS.response"
1894msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
1895msgid "SUN4U-8003-NS.impact"
1896msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
1897msgid "SUN4U-8003-NS.action"
1898msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).  Schedule a repair of the most likely suspect \nlisted in the output.  If the most likely suspect is a package then run \npkgchk on the package(s).\n"
1899#
1900# code: SUN4U-8003-PA
1901# keys: fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.xmits
1902#
1903msgid "SUN4U-8003-PA.type"
1904msgstr "Fault"
1905msgid "SUN4U-8003-PA.severity"
1906msgstr "Critical"
1907msgid "SUN4U-8003-PA.description"
1908msgstr "\nA problem was detected in a system core bus.\n  Refer to %s for more information."
1909msgid "SUN4U-8003-PA.response"
1910msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
1911msgid "SUN4U-8003-PA.impact"
1912msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
1913msgid "SUN4U-8003-PA.action"
1914msgstr "\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
1915#
1916# code: SUN4U-8003-QP
1917# keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.xmits
1918#
1919msgid "SUN4U-8003-QP.type"
1920msgstr "Fault"
1921msgid "SUN4U-8003-QP.severity"
1922msgstr "Critical"
1923msgid "SUN4U-8003-QP.description"
1924msgstr "\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n  Refer to %s for more information."
1925msgid "SUN4U-8003-QP.response"
1926msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
1927msgid "SUN4U-8003-QP.impact"
1928msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
1929msgid "SUN4U-8003-QP.action"
1930msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).  Schedule a repair of the most likely suspect \nlisted in the output.  If the most likely suspect is a package then run \npkgchk on the package(s).\n"
1931#
1932# code: SUN4U-8003-RX
1933# keys: fault.io.datapath fault.io.hbus fault.io.pci.device fault.io.xmits
1934#
1935msgid "SUN4U-8003-RX.type"
1936msgstr "Fault"
1937msgid "SUN4U-8003-RX.severity"
1938msgstr "Critical"
1939msgid "SUN4U-8003-RX.description"
1940msgstr "\nA problem was detected in a system core bus.\n  Refer to %s for more information."
1941msgid "SUN4U-8003-RX.response"
1942msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
1943msgid "SUN4U-8003-RX.impact"
1944msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
1945msgid "SUN4U-8003-RX.action"
1946msgstr "\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
1947#
1948# code: SUN4U-8003-S2
1949# keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.pci.device fault.io.xmits
1950#
1951msgid "SUN4U-8003-S2.type"
1952msgstr "Fault"
1953msgid "SUN4U-8003-S2.severity"
1954msgstr "Critical"
1955msgid "SUN4U-8003-S2.description"
1956msgstr "\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n  Refer to %s for more information."
1957msgid "SUN4U-8003-S2.response"
1958msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
1959msgid "SUN4U-8003-S2.impact"
1960msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
1961msgid "SUN4U-8003-S2.action"
1962msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).  Schedule a repair of the most likely suspect \nlisted in the output.  If the most likely suspect is a package then run \npkgchk on the package(s).\n"
1963#
1964# code: SUN4U-8003-TJ
1965# keys: fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.pci.device fault.io.xmits
1966#
1967msgid "SUN4U-8003-TJ.type"
1968msgstr "Fault"
1969msgid "SUN4U-8003-TJ.severity"
1970msgstr "Critical"
1971msgid "SUN4U-8003-TJ.description"
1972msgstr "\nA problem was detected in a system core bus.\n  Refer to %s for more information."
1973msgid "SUN4U-8003-TJ.response"
1974msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
1975msgid "SUN4U-8003-TJ.impact"
1976msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
1977msgid "SUN4U-8003-TJ.action"
1978msgstr "\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
1979#
1980# code: SUN4U-8003-UE
1981# keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.pci.device fault.io.xmits
1982#
1983msgid "SUN4U-8003-UE.type"
1984msgstr "Fault"
1985msgid "SUN4U-8003-UE.severity"
1986msgstr "Critical"
1987msgid "SUN4U-8003-UE.description"
1988msgstr "\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n  Refer to %s for more information."
1989msgid "SUN4U-8003-UE.response"
1990msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
1991msgid "SUN4U-8003-UE.impact"
1992msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
1993msgid "SUN4U-8003-UE.action"
1994msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).  Schedule a repair of the most likely suspect \nlisted in the output.  If the most likely suspect is a package then run \npkgchk on the package(s).\n"
1995#
1996# code: SUN4U-8003-VQ
1997# keys: fault.io.schizo fault.io.xmits
1998#
1999msgid "SUN4U-8003-VQ.type"
2000msgstr "Fault"
2001msgid "SUN4U-8003-VQ.severity"
2002msgstr "Critical"
2003msgid "SUN4U-8003-VQ.description"
2004msgstr "\nA problem was detected in a system core bus.\n  Refer to %s for more information."
2005msgid "SUN4U-8003-VQ.response"
2006msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
2007msgid "SUN4U-8003-VQ.impact"
2008msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
2009msgid "SUN4U-8003-VQ.action"
2010msgstr "\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
2011#
2012# code: SUN4U-8003-WC
2013# keys: defect.io.pci.driver fault.io.schizo fault.io.xmits
2014#
2015msgid "SUN4U-8003-WC.type"
2016msgstr "Fault"
2017msgid "SUN4U-8003-WC.severity"
2018msgstr "Critical"
2019msgid "SUN4U-8003-WC.description"
2020msgstr "\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n  Refer to %s for more information."
2021msgid "SUN4U-8003-WC.response"
2022msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
2023msgid "SUN4U-8003-WC.impact"
2024msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
2025msgid "SUN4U-8003-WC.action"
2026msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).  Schedule a repair of the most likely suspect \nlisted in the output.  If the most likely suspect is a package then run \npkgchk on the package(s).\n"
2027#
2028# code: SUN4U-8003-XR
2029# keys: fault.io.pci.bus fault.io.schizo fault.io.xmits
2030#
2031msgid "SUN4U-8003-XR.type"
2032msgstr "Fault"
2033msgid "SUN4U-8003-XR.severity"
2034msgstr "Critical"
2035msgid "SUN4U-8003-XR.description"
2036msgstr "\nA problem was detected in a system core bus.\n  Refer to %s for more information."
2037msgid "SUN4U-8003-XR.response"
2038msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
2039msgid "SUN4U-8003-XR.impact"
2040msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
2041msgid "SUN4U-8003-XR.action"
2042msgstr "\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
2043#
2044# code: SUN4U-8003-Y4
2045# keys: defect.io.pci.driver fault.io.pci.bus fault.io.schizo fault.io.xmits
2046#
2047msgid "SUN4U-8003-Y4.type"
2048msgstr "Fault"
2049msgid "SUN4U-8003-Y4.severity"
2050msgstr "Critical"
2051msgid "SUN4U-8003-Y4.description"
2052msgstr "\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n  Refer to %s for more information."
2053msgid "SUN4U-8003-Y4.response"
2054msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
2055msgid "SUN4U-8003-Y4.impact"
2056msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
2057msgid "SUN4U-8003-Y4.action"
2058msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).  Schedule a repair of the most likely suspect \nlisted in the output.  If the most likely suspect is a package then run \npkgchk on the package(s).\n"
2059#
2060# code: SUN4U-8004-0A
2061# keys: fault.io.pci.device fault.io.schizo fault.io.xmits
2062#
2063msgid "SUN4U-8004-0A.type"
2064msgstr "Fault"
2065msgid "SUN4U-8004-0A.severity"
2066msgstr "Critical"
2067msgid "SUN4U-8004-0A.description"
2068msgstr "\nA problem was detected in a system core bus.\n  Refer to %s for more information."
2069msgid "SUN4U-8004-0A.response"
2070msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
2071msgid "SUN4U-8004-0A.impact"
2072msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
2073msgid "SUN4U-8004-0A.action"
2074msgstr "\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
2075#
2076# code: SUN4U-8004-1P
2077# keys: defect.io.pci.driver fault.io.pci.device fault.io.schizo fault.io.xmits
2078#
2079msgid "SUN4U-8004-1P.type"
2080msgstr "Fault"
2081msgid "SUN4U-8004-1P.severity"
2082msgstr "Critical"
2083msgid "SUN4U-8004-1P.description"
2084msgstr "\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n  Refer to %s for more information."
2085msgid "SUN4U-8004-1P.response"
2086msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
2087msgid "SUN4U-8004-1P.impact"
2088msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
2089msgid "SUN4U-8004-1P.action"
2090msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).  Schedule a repair of the most likely suspect \nlisted in the output.  If the most likely suspect is a package then run \npkgchk on the package(s).\n"
2091#
2092# code: SUN4U-8004-25
2093# keys: fault.io.pci.bus fault.io.pci.device fault.io.schizo fault.io.xmits
2094#
2095msgid "SUN4U-8004-25.type"
2096msgstr "Fault"
2097msgid "SUN4U-8004-25.severity"
2098msgstr "Critical"
2099msgid "SUN4U-8004-25.description"
2100msgstr "\nA problem was detected in a system core bus.\n  Refer to %s for more information."
2101msgid "SUN4U-8004-25.response"
2102msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
2103msgid "SUN4U-8004-25.impact"
2104msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
2105msgid "SUN4U-8004-25.action"
2106msgstr "\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
2107#
2108# code: SUN4U-8004-3S
2109# keys: defect.io.pci.driver fault.io.pci.bus fault.io.pci.device fault.io.schizo fault.io.xmits
2110#
2111msgid "SUN4U-8004-3S.type"
2112msgstr "Fault"
2113msgid "SUN4U-8004-3S.severity"
2114msgstr "Critical"
2115msgid "SUN4U-8004-3S.description"
2116msgstr "\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n  Refer to %s for more information."
2117msgid "SUN4U-8004-3S.response"
2118msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
2119msgid "SUN4U-8004-3S.impact"
2120msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
2121msgid "SUN4U-8004-3S.action"
2122msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).  Schedule a repair of the most likely suspect \nlisted in the output.  If the most likely suspect is a package then run \npkgchk on the package(s).\n"
2123#
2124# code: SUN4U-8004-43
2125# keys: fault.io.datapath fault.io.schizo fault.io.xmits
2126#
2127msgid "SUN4U-8004-43.type"
2128msgstr "Fault"
2129msgid "SUN4U-8004-43.severity"
2130msgstr "Critical"
2131msgid "SUN4U-8004-43.description"
2132msgstr "\nA problem was detected in a system core bus.\n  Refer to %s for more information."
2133msgid "SUN4U-8004-43.response"
2134msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
2135msgid "SUN4U-8004-43.impact"
2136msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
2137msgid "SUN4U-8004-43.action"
2138msgstr "\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
2139#
2140# code: SUN4U-8004-5Y
2141# keys: defect.io.pci.driver fault.io.datapath fault.io.schizo fault.io.xmits
2142#
2143msgid "SUN4U-8004-5Y.type"
2144msgstr "Fault"
2145msgid "SUN4U-8004-5Y.severity"
2146msgstr "Critical"
2147msgid "SUN4U-8004-5Y.description"
2148msgstr "\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n  Refer to %s for more information."
2149msgid "SUN4U-8004-5Y.response"
2150msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
2151msgid "SUN4U-8004-5Y.impact"
2152msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
2153msgid "SUN4U-8004-5Y.action"
2154msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).  Schedule a repair of the most likely suspect \nlisted in the output.  If the most likely suspect is a package then run \npkgchk on the package(s).\n"
2155#
2156# code: SUN4U-8004-6D
2157# keys: fault.io.datapath fault.io.pci.bus fault.io.schizo fault.io.xmits
2158#
2159msgid "SUN4U-8004-6D.type"
2160msgstr "Fault"
2161msgid "SUN4U-8004-6D.severity"
2162msgstr "Critical"
2163msgid "SUN4U-8004-6D.description"
2164msgstr "\nA problem was detected in a system core bus.\n  Refer to %s for more information."
2165msgid "SUN4U-8004-6D.response"
2166msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
2167msgid "SUN4U-8004-6D.impact"
2168msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
2169msgid "SUN4U-8004-6D.action"
2170msgstr "\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
2171#
2172# code: SUN4U-8004-7H
2173# keys: defect.io.pci.driver fault.io.datapath fault.io.pci.bus fault.io.schizo fault.io.xmits
2174#
2175msgid "SUN4U-8004-7H.type"
2176msgstr "Fault"
2177msgid "SUN4U-8004-7H.severity"
2178msgstr "Critical"
2179msgid "SUN4U-8004-7H.description"
2180msgstr "\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n  Refer to %s for more information."
2181msgid "SUN4U-8004-7H.response"
2182msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
2183msgid "SUN4U-8004-7H.impact"
2184msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
2185msgid "SUN4U-8004-7H.action"
2186msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).  Schedule a repair of the most likely suspect \nlisted in the output.  If the most likely suspect is a package then run \npkgchk on the package(s).\n"
2187#
2188# code: SUN4U-8004-8R
2189# keys: fault.io.datapath fault.io.pci.device fault.io.schizo fault.io.xmits
2190#
2191msgid "SUN4U-8004-8R.type"
2192msgstr "Fault"
2193msgid "SUN4U-8004-8R.severity"
2194msgstr "Critical"
2195msgid "SUN4U-8004-8R.description"
2196msgstr "\nA problem was detected in a system core bus.\n  Refer to %s for more information."
2197msgid "SUN4U-8004-8R.response"
2198msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
2199msgid "SUN4U-8004-8R.impact"
2200msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
2201msgid "SUN4U-8004-8R.action"
2202msgstr "\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
2203#
2204# code: SUN4U-8004-94
2205# keys: defect.io.pci.driver fault.io.datapath fault.io.pci.device fault.io.schizo fault.io.xmits
2206#
2207msgid "SUN4U-8004-94.type"
2208msgstr "Fault"
2209msgid "SUN4U-8004-94.severity"
2210msgstr "Critical"
2211msgid "SUN4U-8004-94.description"
2212msgstr "\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n  Refer to %s for more information."
2213msgid "SUN4U-8004-94.response"
2214msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
2215msgid "SUN4U-8004-94.impact"
2216msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
2217msgid "SUN4U-8004-94.action"
2218msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).  Schedule a repair of the most likely suspect \nlisted in the output.  If the most likely suspect is a package then run \npkgchk on the package(s).\n"
2219#
2220# code: SUN4U-8004-AQ
2221# keys: fault.io.datapath fault.io.pci.bus fault.io.pci.device fault.io.schizo fault.io.xmits
2222#
2223msgid "SUN4U-8004-AQ.type"
2224msgstr "Fault"
2225msgid "SUN4U-8004-AQ.severity"
2226msgstr "Critical"
2227msgid "SUN4U-8004-AQ.description"
2228msgstr "\nA problem was detected in a system core bus.\n  Refer to %s for more information."
2229msgid "SUN4U-8004-AQ.response"
2230msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
2231msgid "SUN4U-8004-AQ.impact"
2232msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
2233msgid "SUN4U-8004-AQ.action"
2234msgstr "\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
2235#
2236# code: SUN4U-8004-CC
2237# keys: defect.io.pci.driver fault.io.datapath fault.io.pci.bus fault.io.pci.device fault.io.schizo fault.io.xmits
2238#
2239msgid "SUN4U-8004-CC.type"
2240msgstr "Fault"
2241msgid "SUN4U-8004-CC.severity"
2242msgstr "Critical"
2243msgid "SUN4U-8004-CC.description"
2244msgstr "\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n  Refer to %s for more information."
2245msgid "SUN4U-8004-CC.response"
2246msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
2247msgid "SUN4U-8004-CC.impact"
2248msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
2249msgid "SUN4U-8004-CC.action"
2250msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).  Schedule a repair of the most likely suspect \nlisted in the output.  If the most likely suspect is a package then run \npkgchk on the package(s).\n"
2251#
2252# code: SUN4U-8004-DJ
2253# keys: fault.io.hbus fault.io.schizo fault.io.xmits
2254#
2255msgid "SUN4U-8004-DJ.type"
2256msgstr "Fault"
2257msgid "SUN4U-8004-DJ.severity"
2258msgstr "Critical"
2259msgid "SUN4U-8004-DJ.description"
2260msgstr "\nA problem was detected in a system core bus.\n  Refer to %s for more information."
2261msgid "SUN4U-8004-DJ.response"
2262msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
2263msgid "SUN4U-8004-DJ.impact"
2264msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
2265msgid "SUN4U-8004-DJ.action"
2266msgstr "\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
2267#
2268# code: SUN4U-8004-EE
2269# keys: defect.io.pci.driver fault.io.hbus fault.io.schizo fault.io.xmits
2270#
2271msgid "SUN4U-8004-EE.type"
2272msgstr "Fault"
2273msgid "SUN4U-8004-EE.severity"
2274msgstr "Critical"
2275msgid "SUN4U-8004-EE.description"
2276msgstr "\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n  Refer to %s for more information."
2277msgid "SUN4U-8004-EE.response"
2278msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
2279msgid "SUN4U-8004-EE.impact"
2280msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
2281msgid "SUN4U-8004-EE.action"
2282msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).  Schedule a repair of the most likely suspect \nlisted in the output.  If the most likely suspect is a package then run \npkgchk on the package(s).\n"
2283#
2284# code: SUN4U-8004-FX
2285# keys: fault.io.hbus fault.io.pci.bus fault.io.schizo fault.io.xmits
2286#
2287msgid "SUN4U-8004-FX.type"
2288msgstr "Fault"
2289msgid "SUN4U-8004-FX.severity"
2290msgstr "Critical"
2291msgid "SUN4U-8004-FX.description"
2292msgstr "\nA problem was detected in a system core bus.\n  Refer to %s for more information."
2293msgid "SUN4U-8004-FX.response"
2294msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
2295msgid "SUN4U-8004-FX.impact"
2296msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
2297msgid "SUN4U-8004-FX.action"
2298msgstr "\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
2299#
2300# code: SUN4U-8004-G2
2301# keys: defect.io.pci.driver fault.io.hbus fault.io.pci.bus fault.io.schizo fault.io.xmits
2302#
2303msgid "SUN4U-8004-G2.type"
2304msgstr "Fault"
2305msgid "SUN4U-8004-G2.severity"
2306msgstr "Critical"
2307msgid "SUN4U-8004-G2.description"
2308msgstr "\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n  Refer to %s for more information."
2309msgid "SUN4U-8004-G2.response"
2310msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
2311msgid "SUN4U-8004-G2.impact"
2312msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
2313msgid "SUN4U-8004-G2.action"
2314msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).  Schedule a repair of the most likely suspect \nlisted in the output.  If the most likely suspect is a package then run \npkgchk on the package(s).\n"
2315#
2316# code: SUN4U-8004-HS
2317# keys: fault.io.hbus fault.io.pci.device fault.io.schizo fault.io.xmits
2318#
2319msgid "SUN4U-8004-HS.type"
2320msgstr "Fault"
2321msgid "SUN4U-8004-HS.severity"
2322msgstr "Critical"
2323msgid "SUN4U-8004-HS.description"
2324msgstr "\nA problem was detected in a system core bus.\n  Refer to %s for more information."
2325msgid "SUN4U-8004-HS.response"
2326msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
2327msgid "SUN4U-8004-HS.impact"
2328msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
2329msgid "SUN4U-8004-HS.action"
2330msgstr "\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
2331#
2332# code: SUN4U-8004-J5
2333# keys: defect.io.pci.driver fault.io.hbus fault.io.pci.device fault.io.schizo fault.io.xmits
2334#
2335msgid "SUN4U-8004-J5.type"
2336msgstr "Fault"
2337msgid "SUN4U-8004-J5.severity"
2338msgstr "Critical"
2339msgid "SUN4U-8004-J5.description"
2340msgstr "\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n  Refer to %s for more information."
2341msgid "SUN4U-8004-J5.response"
2342msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
2343msgid "SUN4U-8004-J5.impact"
2344msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
2345msgid "SUN4U-8004-J5.action"
2346msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).  Schedule a repair of the most likely suspect \nlisted in the output.  If the most likely suspect is a package then run \npkgchk on the package(s).\n"
2347#
2348# code: SUN4U-8004-KP
2349# keys: fault.io.hbus fault.io.pci.bus fault.io.pci.device fault.io.schizo fault.io.xmits
2350#
2351msgid "SUN4U-8004-KP.type"
2352msgstr "Fault"
2353msgid "SUN4U-8004-KP.severity"
2354msgstr "Critical"
2355msgid "SUN4U-8004-KP.description"
2356msgstr "\nA problem was detected in a system core bus.\n  Refer to %s for more information."
2357msgid "SUN4U-8004-KP.response"
2358msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
2359msgid "SUN4U-8004-KP.impact"
2360msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
2361msgid "SUN4U-8004-KP.action"
2362msgstr "\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
2363#
2364# code: SUN4U-8004-LA
2365# keys: defect.io.pci.driver fault.io.hbus fault.io.pci.bus fault.io.pci.device fault.io.schizo fault.io.xmits
2366#
2367msgid "SUN4U-8004-LA.type"
2368msgstr "Fault"
2369msgid "SUN4U-8004-LA.severity"
2370msgstr "Critical"
2371msgid "SUN4U-8004-LA.description"
2372msgstr "\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n  Refer to %s for more information."
2373msgid "SUN4U-8004-LA.response"
2374msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
2375msgid "SUN4U-8004-LA.impact"
2376msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
2377msgid "SUN4U-8004-LA.action"
2378msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).  Schedule a repair of the most likely suspect \nlisted in the output.  If the most likely suspect is a package then run \npkgchk on the package(s).\n"
2379#
2380# code: SUN4U-8004-MH
2381# keys: fault.io.datapath fault.io.hbus fault.io.schizo fault.io.xmits
2382#
2383msgid "SUN4U-8004-MH.type"
2384msgstr "Fault"
2385msgid "SUN4U-8004-MH.severity"
2386msgstr "Critical"
2387msgid "SUN4U-8004-MH.description"
2388msgstr "\nA problem was detected in a system core bus.\n  Refer to %s for more information."
2389msgid "SUN4U-8004-MH.response"
2390msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
2391msgid "SUN4U-8004-MH.impact"
2392msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
2393msgid "SUN4U-8004-MH.action"
2394msgstr "\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
2395#
2396# code: SUN4U-8004-ND
2397# keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.schizo fault.io.xmits
2398#
2399msgid "SUN4U-8004-ND.type"
2400msgstr "Fault"
2401msgid "SUN4U-8004-ND.severity"
2402msgstr "Critical"
2403msgid "SUN4U-8004-ND.description"
2404msgstr "\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n  Refer to %s for more information."
2405msgid "SUN4U-8004-ND.response"
2406msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
2407msgid "SUN4U-8004-ND.impact"
2408msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
2409msgid "SUN4U-8004-ND.action"
2410msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).  Schedule a repair of the most likely suspect \nlisted in the output.  If the most likely suspect is a package then run \npkgchk on the package(s).\n"
2411#
2412# code: SUN4U-8004-PY
2413# keys: fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.schizo fault.io.xmits
2414#
2415msgid "SUN4U-8004-PY.type"
2416msgstr "Fault"
2417msgid "SUN4U-8004-PY.severity"
2418msgstr "Critical"
2419msgid "SUN4U-8004-PY.description"
2420msgstr "\nA problem was detected in a system core bus.\n  Refer to %s for more information."
2421msgid "SUN4U-8004-PY.response"
2422msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
2423msgid "SUN4U-8004-PY.impact"
2424msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
2425msgid "SUN4U-8004-PY.action"
2426msgstr "\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
2427#
2428# code: SUN4U-8004-Q3
2429# keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.schizo fault.io.xmits
2430#
2431msgid "SUN4U-8004-Q3.type"
2432msgstr "Fault"
2433msgid "SUN4U-8004-Q3.severity"
2434msgstr "Critical"
2435msgid "SUN4U-8004-Q3.description"
2436msgstr "\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n  Refer to %s for more information."
2437msgid "SUN4U-8004-Q3.response"
2438msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
2439msgid "SUN4U-8004-Q3.impact"
2440msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
2441msgid "SUN4U-8004-Q3.action"
2442msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).  Schedule a repair of the most likely suspect \nlisted in the output.  If the most likely suspect is a package then run \npkgchk on the package(s).\n"
2443#
2444# code: SUN4U-8004-RC
2445# keys: fault.io.datapath fault.io.hbus fault.io.pci.device fault.io.schizo fault.io.xmits
2446#
2447msgid "SUN4U-8004-RC.type"
2448msgstr "Fault"
2449msgid "SUN4U-8004-RC.severity"
2450msgstr "Critical"
2451msgid "SUN4U-8004-RC.description"
2452msgstr "\nA problem was detected in a system core bus.\n  Refer to %s for more information."
2453msgid "SUN4U-8004-RC.response"
2454msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
2455msgid "SUN4U-8004-RC.impact"
2456msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
2457msgid "SUN4U-8004-RC.action"
2458msgstr "\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
2459#
2460# code: SUN4U-8004-SQ
2461# keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.pci.device fault.io.schizo fault.io.xmits
2462#
2463msgid "SUN4U-8004-SQ.type"
2464msgstr "Fault"
2465msgid "SUN4U-8004-SQ.severity"
2466msgstr "Critical"
2467msgid "SUN4U-8004-SQ.description"
2468msgstr "\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n  Refer to %s for more information."
2469msgid "SUN4U-8004-SQ.response"
2470msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
2471msgid "SUN4U-8004-SQ.impact"
2472msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
2473msgid "SUN4U-8004-SQ.action"
2474msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).  Schedule a repair of the most likely suspect \nlisted in the output.  If the most likely suspect is a package then run \npkgchk on the package(s).\n"
2475#
2476# code: SUN4U-8004-T4
2477# keys: fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.pci.device fault.io.schizo fault.io.xmits
2478#
2479msgid "SUN4U-8004-T4.type"
2480msgstr "Fault"
2481msgid "SUN4U-8004-T4.severity"
2482msgstr "Critical"
2483msgid "SUN4U-8004-T4.description"
2484msgstr "\nA problem was detected in a system core bus.\n  Refer to %s for more information."
2485msgid "SUN4U-8004-T4.response"
2486msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
2487msgid "SUN4U-8004-T4.impact"
2488msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
2489msgid "SUN4U-8004-T4.action"
2490msgstr "\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
2491#
2492# code: SUN4U-8004-UR
2493# keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.pci.device fault.io.schizo fault.io.xmits
2494#
2495msgid "SUN4U-8004-UR.type"
2496msgstr "Fault"
2497msgid "SUN4U-8004-UR.severity"
2498msgstr "Critical"
2499msgid "SUN4U-8004-UR.description"
2500msgstr "\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n  Refer to %s for more information."
2501msgid "SUN4U-8004-UR.response"
2502msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
2503msgid "SUN4U-8004-UR.impact"
2504msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
2505msgid "SUN4U-8004-UR.action"
2506msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).  Schedule a repair of the most likely suspect \nlisted in the output.  If the most likely suspect is a package then run \npkgchk on the package(s).\n"
2507#
2508# code: SUN4U-8004-V2
2509# keys: fault.io.psycho
2510#
2511msgid "SUN4U-8004-V2.type"
2512msgstr "Fault"
2513msgid "SUN4U-8004-V2.severity"
2514msgstr "Critical"
2515msgid "SUN4U-8004-V2.description"
2516msgstr "\nA problem was detected in a system core bus.\n  Refer to %s for more information."
2517msgid "SUN4U-8004-V2.response"
2518msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
2519msgid "SUN4U-8004-V2.impact"
2520msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
2521msgid "SUN4U-8004-V2.action"
2522msgstr "\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
2523#
2524# code: SUN4U-8004-WX
2525# keys: defect.io.pci.driver fault.io.psycho
2526#
2527msgid "SUN4U-8004-WX.type"
2528msgstr "Fault"
2529msgid "SUN4U-8004-WX.severity"
2530msgstr "Critical"
2531msgid "SUN4U-8004-WX.description"
2532msgstr "\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n  Refer to %s for more information."
2533msgid "SUN4U-8004-WX.response"
2534msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
2535msgid "SUN4U-8004-WX.impact"
2536msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
2537msgid "SUN4U-8004-WX.action"
2538msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).  Schedule a repair of the most likely suspect \nlisted in the output.  If the most likely suspect is a package then run \npkgchk on the package(s).\n"
2539#
2540# code: SUN4U-8004-XE
2541# keys: fault.io.datapath fault.io.psycho
2542#
2543msgid "SUN4U-8004-XE.type"
2544msgstr "Fault"
2545msgid "SUN4U-8004-XE.severity"
2546msgstr "Critical"
2547msgid "SUN4U-8004-XE.description"
2548msgstr "\nA problem was detected in a system core bus.\n  Refer to %s for more information."
2549msgid "SUN4U-8004-XE.response"
2550msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
2551msgid "SUN4U-8004-XE.impact"
2552msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
2553msgid "SUN4U-8004-XE.action"
2554msgstr "\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
2555#
2556# code: SUN4U-8004-YJ
2557# keys: defect.io.pci.driver fault.io.datapath fault.io.psycho
2558#
2559msgid "SUN4U-8004-YJ.type"
2560msgstr "Fault"
2561msgid "SUN4U-8004-YJ.severity"
2562msgstr "Critical"
2563msgid "SUN4U-8004-YJ.description"
2564msgstr "\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n  Refer to %s for more information."
2565msgid "SUN4U-8004-YJ.response"
2566msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
2567msgid "SUN4U-8004-YJ.impact"
2568msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
2569msgid "SUN4U-8004-YJ.action"
2570msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).  Schedule a repair of the most likely suspect \nlisted in the output.  If the most likely suspect is a package then run \npkgchk on the package(s).\n"
2571#
2572# code: SUN4U-8005-0E
2573# keys: fault.io.hbus fault.io.psycho
2574#
2575msgid "SUN4U-8005-0E.type"
2576msgstr "Fault"
2577msgid "SUN4U-8005-0E.severity"
2578msgstr "Critical"
2579msgid "SUN4U-8005-0E.description"
2580msgstr "\nA problem was detected in a system core bus.\n  Refer to %s for more information."
2581msgid "SUN4U-8005-0E.response"
2582msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
2583msgid "SUN4U-8005-0E.impact"
2584msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
2585msgid "SUN4U-8005-0E.action"
2586msgstr "\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
2587#
2588# code: SUN4U-8005-1J
2589# keys: defect.io.pci.driver fault.io.hbus fault.io.psycho
2590#
2591msgid "SUN4U-8005-1J.type"
2592msgstr "Fault"
2593msgid "SUN4U-8005-1J.severity"
2594msgstr "Critical"
2595msgid "SUN4U-8005-1J.description"
2596msgstr "\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n  Refer to %s for more information."
2597msgid "SUN4U-8005-1J.response"
2598msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
2599msgid "SUN4U-8005-1J.impact"
2600msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
2601msgid "SUN4U-8005-1J.action"
2602msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).  Schedule a repair of the most likely suspect \nlisted in the output.  If the most likely suspect is a package then run \npkgchk on the package(s).\n"
2603#
2604# code: SUN4U-8005-22
2605# keys: fault.io.datapath fault.io.hbus fault.io.psycho
2606#
2607msgid "SUN4U-8005-22.type"
2608msgstr "Fault"
2609msgid "SUN4U-8005-22.severity"
2610msgstr "Critical"
2611msgid "SUN4U-8005-22.description"
2612msgstr "\nA problem was detected in a system core bus.\n  Refer to %s for more information."
2613msgid "SUN4U-8005-22.response"
2614msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
2615msgid "SUN4U-8005-22.impact"
2616msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
2617msgid "SUN4U-8005-22.action"
2618msgstr "\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
2619#
2620# code: SUN4U-8005-3X
2621# keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.psycho
2622#
2623msgid "SUN4U-8005-3X.type"
2624msgstr "Fault"
2625msgid "SUN4U-8005-3X.severity"
2626msgstr "Critical"
2627msgid "SUN4U-8005-3X.description"
2628msgstr "\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n  Refer to %s for more information."
2629msgid "SUN4U-8005-3X.response"
2630msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
2631msgid "SUN4U-8005-3X.impact"
2632msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
2633msgid "SUN4U-8005-3X.action"
2634msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).  Schedule a repair of the most likely suspect \nlisted in the output.  If the most likely suspect is a package then run \npkgchk on the package(s).\n"
2635#
2636# code: SUN4U-8005-44
2637# keys: fault.io.pci.bus fault.io.psycho
2638#
2639msgid "SUN4U-8005-44.type"
2640msgstr "Fault"
2641msgid "SUN4U-8005-44.severity"
2642msgstr "Critical"
2643msgid "SUN4U-8005-44.description"
2644msgstr "\nA problem was detected in a system core bus.\n  Refer to %s for more information."
2645msgid "SUN4U-8005-44.response"
2646msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
2647msgid "SUN4U-8005-44.impact"
2648msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
2649msgid "SUN4U-8005-44.action"
2650msgstr "\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
2651#
2652# code: SUN4U-8005-5R
2653# keys: defect.io.pci.driver fault.io.pci.bus fault.io.psycho
2654#
2655msgid "SUN4U-8005-5R.type"
2656msgstr "Fault"
2657msgid "SUN4U-8005-5R.severity"
2658msgstr "Critical"
2659msgid "SUN4U-8005-5R.description"
2660msgstr "\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n  Refer to %s for more information."
2661msgid "SUN4U-8005-5R.response"
2662msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
2663msgid "SUN4U-8005-5R.impact"
2664msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
2665msgid "SUN4U-8005-5R.action"
2666msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).  Schedule a repair of the most likely suspect \nlisted in the output.  If the most likely suspect is a package then run \npkgchk on the package(s).\n"
2667#
2668# code: SUN4U-8005-6C
2669# keys: fault.io.datapath fault.io.pci.bus fault.io.psycho
2670#
2671msgid "SUN4U-8005-6C.type"
2672msgstr "Fault"
2673msgid "SUN4U-8005-6C.severity"
2674msgstr "Critical"
2675msgid "SUN4U-8005-6C.description"
2676msgstr "\nA problem was detected in a system core bus.\n  Refer to %s for more information."
2677msgid "SUN4U-8005-6C.response"
2678msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
2679msgid "SUN4U-8005-6C.impact"
2680msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
2681msgid "SUN4U-8005-6C.action"
2682msgstr "\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
2683#
2684# code: SUN4U-8005-7Q
2685# keys: defect.io.pci.driver fault.io.datapath fault.io.pci.bus fault.io.psycho
2686#
2687msgid "SUN4U-8005-7Q.type"
2688msgstr "Fault"
2689msgid "SUN4U-8005-7Q.severity"
2690msgstr "Critical"
2691msgid "SUN4U-8005-7Q.description"
2692msgstr "\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n  Refer to %s for more information."
2693msgid "SUN4U-8005-7Q.response"
2694msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
2695msgid "SUN4U-8005-7Q.impact"
2696msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
2697msgid "SUN4U-8005-7Q.action"
2698msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).  Schedule a repair of the most likely suspect \nlisted in the output.  If the most likely suspect is a package then run \npkgchk on the package(s).\n"
2699#
2700# code: SUN4U-8005-8Y
2701# keys: fault.io.hbus fault.io.pci.bus fault.io.psycho
2702#
2703msgid "SUN4U-8005-8Y.type"
2704msgstr "Fault"
2705msgid "SUN4U-8005-8Y.severity"
2706msgstr "Critical"
2707msgid "SUN4U-8005-8Y.description"
2708msgstr "\nA problem was detected in a system core bus.\n  Refer to %s for more information."
2709msgid "SUN4U-8005-8Y.response"
2710msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
2711msgid "SUN4U-8005-8Y.impact"
2712msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
2713msgid "SUN4U-8005-8Y.action"
2714msgstr "\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
2715#
2716# code: SUN4U-8005-93
2717# keys: defect.io.pci.driver fault.io.hbus fault.io.pci.bus fault.io.psycho
2718#
2719msgid "SUN4U-8005-93.type"
2720msgstr "Fault"
2721msgid "SUN4U-8005-93.severity"
2722msgstr "Critical"
2723msgid "SUN4U-8005-93.description"
2724msgstr "\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n  Refer to %s for more information."
2725msgid "SUN4U-8005-93.response"
2726msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
2727msgid "SUN4U-8005-93.impact"
2728msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
2729msgid "SUN4U-8005-93.action"
2730msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).  Schedule a repair of the most likely suspect \nlisted in the output.  If the most likely suspect is a package then run \npkgchk on the package(s).\n"
2731#
2732# code: SUN4U-8005-AH
2733# keys: fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.psycho
2734#
2735msgid "SUN4U-8005-AH.type"
2736msgstr "Fault"
2737msgid "SUN4U-8005-AH.severity"
2738msgstr "Critical"
2739msgid "SUN4U-8005-AH.description"
2740msgstr "\nA problem was detected in a system core bus.\n  Refer to %s for more information."
2741msgid "SUN4U-8005-AH.response"
2742msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
2743msgid "SUN4U-8005-AH.impact"
2744msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
2745msgid "SUN4U-8005-AH.action"
2746msgstr "\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
2747#
2748# code: SUN4U-8005-CD
2749# keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.psycho
2750#
2751msgid "SUN4U-8005-CD.type"
2752msgstr "Fault"
2753msgid "SUN4U-8005-CD.severity"
2754msgstr "Critical"
2755msgid "SUN4U-8005-CD.description"
2756msgstr "\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n  Refer to %s for more information."
2757msgid "SUN4U-8005-CD.response"
2758msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
2759msgid "SUN4U-8005-CD.impact"
2760msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
2761msgid "SUN4U-8005-CD.action"
2762msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).  Schedule a repair of the most likely suspect \nlisted in the output.  If the most likely suspect is a package then run \npkgchk on the package(s).\n"
2763#
2764# code: SUN4U-8005-DP
2765# keys: fault.io.pci.device fault.io.psycho
2766#
2767msgid "SUN4U-8005-DP.type"
2768msgstr "Fault"
2769msgid "SUN4U-8005-DP.severity"
2770msgstr "Critical"
2771msgid "SUN4U-8005-DP.description"
2772msgstr "\nA problem was detected in a system core bus.\n  Refer to %s for more information."
2773msgid "SUN4U-8005-DP.response"
2774msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
2775msgid "SUN4U-8005-DP.impact"
2776msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
2777msgid "SUN4U-8005-DP.action"
2778msgstr "\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
2779#
2780# code: SUN4U-8005-EA
2781# keys: defect.io.pci.driver fault.io.pci.device fault.io.psycho
2782#
2783msgid "SUN4U-8005-EA.type"
2784msgstr "Fault"
2785msgid "SUN4U-8005-EA.severity"
2786msgstr "Critical"
2787msgid "SUN4U-8005-EA.description"
2788msgstr "\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n  Refer to %s for more information."
2789msgid "SUN4U-8005-EA.response"
2790msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
2791msgid "SUN4U-8005-EA.impact"
2792msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
2793msgid "SUN4U-8005-EA.action"
2794msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).  Schedule a repair of the most likely suspect \nlisted in the output.  If the most likely suspect is a package then run \npkgchk on the package(s).\n"
2795#
2796# code: SUN4U-8005-FS
2797# keys: fault.io.datapath fault.io.pci.device fault.io.psycho
2798#
2799msgid "SUN4U-8005-FS.type"
2800msgstr "Fault"
2801msgid "SUN4U-8005-FS.severity"
2802msgstr "Critical"
2803msgid "SUN4U-8005-FS.description"
2804msgstr "\nA problem was detected in a system core bus.\n  Refer to %s for more information."
2805msgid "SUN4U-8005-FS.response"
2806msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
2807msgid "SUN4U-8005-FS.impact"
2808msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
2809msgid "SUN4U-8005-FS.action"
2810msgstr "\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
2811#
2812# code: SUN4U-8005-G5
2813# keys: defect.io.pci.driver fault.io.datapath fault.io.pci.device fault.io.psycho
2814#
2815msgid "SUN4U-8005-G5.type"
2816msgstr "Fault"
2817msgid "SUN4U-8005-G5.severity"
2818msgstr "Critical"
2819msgid "SUN4U-8005-G5.description"
2820msgstr "\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n  Refer to %s for more information."
2821msgid "SUN4U-8005-G5.response"
2822msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
2823msgid "SUN4U-8005-G5.impact"
2824msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
2825msgid "SUN4U-8005-G5.action"
2826msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).  Schedule a repair of the most likely suspect \nlisted in the output.  If the most likely suspect is a package then run \npkgchk on the package(s).\n"
2827#
2828# code: SUN4U-8005-HX
2829# keys: fault.io.hbus fault.io.pci.device fault.io.psycho
2830#
2831msgid "SUN4U-8005-HX.type"
2832msgstr "Fault"
2833msgid "SUN4U-8005-HX.severity"
2834msgstr "Critical"
2835msgid "SUN4U-8005-HX.description"
2836msgstr "\nA problem was detected in a system core bus.\n  Refer to %s for more information."
2837msgid "SUN4U-8005-HX.response"
2838msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
2839msgid "SUN4U-8005-HX.impact"
2840msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
2841msgid "SUN4U-8005-HX.action"
2842msgstr "\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
2843#
2844# code: SUN4U-8005-J2
2845# keys: defect.io.pci.driver fault.io.hbus fault.io.pci.device fault.io.psycho
2846#
2847msgid "SUN4U-8005-J2.type"
2848msgstr "Fault"
2849msgid "SUN4U-8005-J2.severity"
2850msgstr "Critical"
2851msgid "SUN4U-8005-J2.description"
2852msgstr "\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n  Refer to %s for more information."
2853msgid "SUN4U-8005-J2.response"
2854msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
2855msgid "SUN4U-8005-J2.impact"
2856msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
2857msgid "SUN4U-8005-J2.action"
2858msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).  Schedule a repair of the most likely suspect \nlisted in the output.  If the most likely suspect is a package then run \npkgchk on the package(s).\n"
2859#
2860# code: SUN4U-8005-KJ
2861# keys: fault.io.datapath fault.io.hbus fault.io.pci.device fault.io.psycho
2862#
2863msgid "SUN4U-8005-KJ.type"
2864msgstr "Fault"
2865msgid "SUN4U-8005-KJ.severity"
2866msgstr "Critical"
2867msgid "SUN4U-8005-KJ.description"
2868msgstr "\nA problem was detected in a system core bus.\n  Refer to %s for more information."
2869msgid "SUN4U-8005-KJ.response"
2870msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
2871msgid "SUN4U-8005-KJ.impact"
2872msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
2873msgid "SUN4U-8005-KJ.action"
2874msgstr "\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
2875#
2876# code: SUN4U-8005-LE
2877# keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.pci.device fault.io.psycho
2878#
2879msgid "SUN4U-8005-LE.type"
2880msgstr "Fault"
2881msgid "SUN4U-8005-LE.severity"
2882msgstr "Critical"
2883msgid "SUN4U-8005-LE.description"
2884msgstr "\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n  Refer to %s for more information."
2885msgid "SUN4U-8005-LE.response"
2886msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
2887msgid "SUN4U-8005-LE.impact"
2888msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
2889msgid "SUN4U-8005-LE.action"
2890msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).  Schedule a repair of the most likely suspect \nlisted in the output.  If the most likely suspect is a package then run \npkgchk on the package(s).\n"
2891#
2892# code: SUN4U-8005-MQ
2893# keys: fault.io.pci.bus fault.io.pci.device fault.io.psycho
2894#
2895msgid "SUN4U-8005-MQ.type"
2896msgstr "Fault"
2897msgid "SUN4U-8005-MQ.severity"
2898msgstr "Critical"
2899msgid "SUN4U-8005-MQ.description"
2900msgstr "\nA problem was detected in a system core bus.\n  Refer to %s for more information."
2901msgid "SUN4U-8005-MQ.response"
2902msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
2903msgid "SUN4U-8005-MQ.impact"
2904msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
2905msgid "SUN4U-8005-MQ.action"
2906msgstr "\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
2907#
2908# code: SUN4U-8005-NC
2909# keys: defect.io.pci.driver fault.io.pci.bus fault.io.pci.device fault.io.psycho
2910#
2911msgid "SUN4U-8005-NC.type"
2912msgstr "Fault"
2913msgid "SUN4U-8005-NC.severity"
2914msgstr "Critical"
2915msgid "SUN4U-8005-NC.description"
2916msgstr "\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n  Refer to %s for more information."
2917msgid "SUN4U-8005-NC.response"
2918msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
2919msgid "SUN4U-8005-NC.impact"
2920msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
2921msgid "SUN4U-8005-NC.action"
2922msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).  Schedule a repair of the most likely suspect \nlisted in the output.  If the most likely suspect is a package then run \npkgchk on the package(s).\n"
2923#
2924# code: SUN4U-8005-PR
2925# keys: fault.io.datapath fault.io.pci.bus fault.io.pci.device fault.io.psycho
2926#
2927msgid "SUN4U-8005-PR.type"
2928msgstr "Fault"
2929msgid "SUN4U-8005-PR.severity"
2930msgstr "Critical"
2931msgid "SUN4U-8005-PR.description"
2932msgstr "\nA problem was detected in a system core bus.\n  Refer to %s for more information."
2933msgid "SUN4U-8005-PR.response"
2934msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
2935msgid "SUN4U-8005-PR.impact"
2936msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
2937msgid "SUN4U-8005-PR.action"
2938msgstr "\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
2939#
2940# code: SUN4U-8005-Q4
2941# keys: defect.io.pci.driver fault.io.datapath fault.io.pci.bus fault.io.pci.device fault.io.psycho
2942#
2943msgid "SUN4U-8005-Q4.type"
2944msgstr "Fault"
2945msgid "SUN4U-8005-Q4.severity"
2946msgstr "Critical"
2947msgid "SUN4U-8005-Q4.description"
2948msgstr "\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n  Refer to %s for more information."
2949msgid "SUN4U-8005-Q4.response"
2950msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
2951msgid "SUN4U-8005-Q4.impact"
2952msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
2953msgid "SUN4U-8005-Q4.action"
2954msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).  Schedule a repair of the most likely suspect \nlisted in the output.  If the most likely suspect is a package then run \npkgchk on the package(s).\n"
2955#
2956# code: SUN4U-8005-RD
2957# keys: fault.io.hbus fault.io.pci.bus fault.io.pci.device fault.io.psycho
2958#
2959msgid "SUN4U-8005-RD.type"
2960msgstr "Fault"
2961msgid "SUN4U-8005-RD.severity"
2962msgstr "Critical"
2963msgid "SUN4U-8005-RD.description"
2964msgstr "\nA problem was detected in a system core bus.\n  Refer to %s for more information."
2965msgid "SUN4U-8005-RD.response"
2966msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
2967msgid "SUN4U-8005-RD.impact"
2968msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
2969msgid "SUN4U-8005-RD.action"
2970msgstr "\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
2971#
2972# code: SUN4U-8005-SH
2973# keys: defect.io.pci.driver fault.io.hbus fault.io.pci.bus fault.io.pci.device fault.io.psycho
2974#
2975msgid "SUN4U-8005-SH.type"
2976msgstr "Fault"
2977msgid "SUN4U-8005-SH.severity"
2978msgstr "Critical"
2979msgid "SUN4U-8005-SH.description"
2980msgstr "\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n  Refer to %s for more information."
2981msgid "SUN4U-8005-SH.response"
2982msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
2983msgid "SUN4U-8005-SH.impact"
2984msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
2985msgid "SUN4U-8005-SH.action"
2986msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).  Schedule a repair of the most likely suspect \nlisted in the output.  If the most likely suspect is a package then run \npkgchk on the package(s).\n"
2987#
2988# code: SUN4U-8005-T3
2989# keys: fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.pci.device fault.io.psycho
2990#
2991msgid "SUN4U-8005-T3.type"
2992msgstr "Fault"
2993msgid "SUN4U-8005-T3.severity"
2994msgstr "Critical"
2995msgid "SUN4U-8005-T3.description"
2996msgstr "\nA problem was detected in a system core bus.\n  Refer to %s for more information."
2997msgid "SUN4U-8005-T3.response"
2998msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
2999msgid "SUN4U-8005-T3.impact"
3000msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
3001msgid "SUN4U-8005-T3.action"
3002msgstr "\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
3003#
3004# code: SUN4U-8005-UY
3005# keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.pci.device fault.io.psycho
3006#
3007msgid "SUN4U-8005-UY.type"
3008msgstr "Fault"
3009msgid "SUN4U-8005-UY.severity"
3010msgstr "Critical"
3011msgid "SUN4U-8005-UY.description"
3012msgstr "\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n  Refer to %s for more information."
3013msgid "SUN4U-8005-UY.response"
3014msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
3015msgid "SUN4U-8005-UY.impact"
3016msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
3017msgid "SUN4U-8005-UY.action"
3018msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).  Schedule a repair of the most likely suspect \nlisted in the output.  If the most likely suspect is a package then run \npkgchk on the package(s).\n"
3019#
3020# code: SUN4U-8005-V5
3021# keys: fault.io.tomatillo
3022#
3023msgid "SUN4U-8005-V5.type"
3024msgstr "Fault"
3025msgid "SUN4U-8005-V5.severity"
3026msgstr "Critical"
3027msgid "SUN4U-8005-V5.description"
3028msgstr "\nA problem was detected in a system core bus.\n  Refer to %s for more information."
3029msgid "SUN4U-8005-V5.response"
3030msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
3031msgid "SUN4U-8005-V5.impact"
3032msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
3033msgid "SUN4U-8005-V5.action"
3034msgstr "\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
3035#
3036# code: SUN4U-8005-WS
3037# keys: defect.io.pci.driver fault.io.tomatillo
3038#
3039msgid "SUN4U-8005-WS.type"
3040msgstr "Fault"
3041msgid "SUN4U-8005-WS.severity"
3042msgstr "Critical"
3043msgid "SUN4U-8005-WS.description"
3044msgstr "\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n  Refer to %s for more information."
3045msgid "SUN4U-8005-WS.response"
3046msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
3047msgid "SUN4U-8005-WS.impact"
3048msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
3049msgid "SUN4U-8005-WS.action"
3050msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).  Schedule a repair of the most likely suspect \nlisted in the output.  If the most likely suspect is a package then run \npkgchk on the package(s).\n"
3051#
3052# code: SUN4U-8005-XA
3053# keys: fault.io.datapath fault.io.tomatillo
3054#
3055msgid "SUN4U-8005-XA.type"
3056msgstr "Fault"
3057msgid "SUN4U-8005-XA.severity"
3058msgstr "Critical"
3059msgid "SUN4U-8005-XA.description"
3060msgstr "\nA problem was detected in a system core bus.\n  Refer to %s for more information."
3061msgid "SUN4U-8005-XA.response"
3062msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
3063msgid "SUN4U-8005-XA.impact"
3064msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
3065msgid "SUN4U-8005-XA.action"
3066msgstr "\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
3067#
3068# code: SUN4U-8005-YP
3069# keys: defect.io.pci.driver fault.io.datapath fault.io.tomatillo
3070#
3071msgid "SUN4U-8005-YP.type"
3072msgstr "Fault"
3073msgid "SUN4U-8005-YP.severity"
3074msgstr "Critical"
3075msgid "SUN4U-8005-YP.description"
3076msgstr "\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n  Refer to %s for more information."
3077msgid "SUN4U-8005-YP.response"
3078msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
3079msgid "SUN4U-8005-YP.impact"
3080msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
3081msgid "SUN4U-8005-YP.action"
3082msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).  Schedule a repair of the most likely suspect \nlisted in the output.  If the most likely suspect is a package then run \npkgchk on the package(s).\n"
3083#
3084# code: SUN4U-8006-04
3085# keys: fault.io.hbus fault.io.tomatillo
3086#
3087msgid "SUN4U-8006-04.type"
3088msgstr "Fault"
3089msgid "SUN4U-8006-04.severity"
3090msgstr "Critical"
3091msgid "SUN4U-8006-04.description"
3092msgstr "\nA problem was detected in a system core bus.\n  Refer to %s for more information."
3093msgid "SUN4U-8006-04.response"
3094msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
3095msgid "SUN4U-8006-04.impact"
3096msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
3097msgid "SUN4U-8006-04.action"
3098msgstr "\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
3099#
3100# code: SUN4U-8006-1R
3101# keys: defect.io.pci.driver fault.io.hbus fault.io.tomatillo
3102#
3103msgid "SUN4U-8006-1R.type"
3104msgstr "Fault"
3105msgid "SUN4U-8006-1R.severity"
3106msgstr "Critical"
3107msgid "SUN4U-8006-1R.description"
3108msgstr "\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n  Refer to %s for more information."
3109msgid "SUN4U-8006-1R.response"
3110msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
3111msgid "SUN4U-8006-1R.impact"
3112msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
3113msgid "SUN4U-8006-1R.action"
3114msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).  Schedule a repair of the most likely suspect \nlisted in the output.  If the most likely suspect is a package then run \npkgchk on the package(s).\n"
3115#
3116# code: SUN4U-8006-2C
3117# keys: fault.io.datapath fault.io.hbus fault.io.tomatillo
3118#
3119msgid "SUN4U-8006-2C.type"
3120msgstr "Fault"
3121msgid "SUN4U-8006-2C.severity"
3122msgstr "Critical"
3123msgid "SUN4U-8006-2C.description"
3124msgstr "\nA problem was detected in a system core bus.\n  Refer to %s for more information."
3125msgid "SUN4U-8006-2C.response"
3126msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
3127msgid "SUN4U-8006-2C.impact"
3128msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
3129msgid "SUN4U-8006-2C.action"
3130msgstr "\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
3131#
3132# code: SUN4U-8006-3Q
3133# keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.tomatillo
3134#
3135msgid "SUN4U-8006-3Q.type"
3136msgstr "Fault"
3137msgid "SUN4U-8006-3Q.severity"
3138msgstr "Critical"
3139msgid "SUN4U-8006-3Q.description"
3140msgstr "\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n  Refer to %s for more information."
3141msgid "SUN4U-8006-3Q.response"
3142msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
3143msgid "SUN4U-8006-3Q.impact"
3144msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
3145msgid "SUN4U-8006-3Q.action"
3146msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).  Schedule a repair of the most likely suspect \nlisted in the output.  If the most likely suspect is a package then run \npkgchk on the package(s).\n"
3147#
3148# code: SUN4U-8006-4E
3149# keys: fault.io.pci.bus fault.io.tomatillo
3150#
3151msgid "SUN4U-8006-4E.type"
3152msgstr "Fault"
3153msgid "SUN4U-8006-4E.severity"
3154msgstr "Critical"
3155msgid "SUN4U-8006-4E.description"
3156msgstr "\nA problem was detected in a system core bus.\n  Refer to %s for more information."
3157msgid "SUN4U-8006-4E.response"
3158msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
3159msgid "SUN4U-8006-4E.impact"
3160msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
3161msgid "SUN4U-8006-4E.action"
3162msgstr "\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
3163#
3164# code: SUN4U-8006-5J
3165# keys: defect.io.pci.driver fault.io.pci.bus fault.io.tomatillo
3166#
3167msgid "SUN4U-8006-5J.type"
3168msgstr "Fault"
3169msgid "SUN4U-8006-5J.severity"
3170msgstr "Critical"
3171msgid "SUN4U-8006-5J.description"
3172msgstr "\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n  Refer to %s for more information."
3173msgid "SUN4U-8006-5J.response"
3174msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
3175msgid "SUN4U-8006-5J.impact"
3176msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
3177msgid "SUN4U-8006-5J.action"
3178msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).  Schedule a repair of the most likely suspect \nlisted in the output.  If the most likely suspect is a package then run \npkgchk on the package(s).\n"
3179#
3180# code: SUN4U-8006-62
3181# keys: fault.io.datapath fault.io.pci.bus fault.io.tomatillo
3182#
3183msgid "SUN4U-8006-62.type"
3184msgstr "Fault"
3185msgid "SUN4U-8006-62.severity"
3186msgstr "Critical"
3187msgid "SUN4U-8006-62.description"
3188msgstr "\nA problem was detected in a system core bus.\n  Refer to %s for more information."
3189msgid "SUN4U-8006-62.response"
3190msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
3191msgid "SUN4U-8006-62.impact"
3192msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
3193msgid "SUN4U-8006-62.action"
3194msgstr "\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
3195#
3196# code: SUN4U-8006-7X
3197# keys: defect.io.pci.driver fault.io.datapath fault.io.pci.bus fault.io.tomatillo
3198#
3199msgid "SUN4U-8006-7X.type"
3200msgstr "Fault"
3201msgid "SUN4U-8006-7X.severity"
3202msgstr "Critical"
3203msgid "SUN4U-8006-7X.description"
3204msgstr "\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n  Refer to %s for more information."
3205msgid "SUN4U-8006-7X.response"
3206msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
3207msgid "SUN4U-8006-7X.impact"
3208msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
3209msgid "SUN4U-8006-7X.action"
3210msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).  Schedule a repair of the most likely suspect \nlisted in the output.  If the most likely suspect is a package then run \npkgchk on the package(s).\n"
3211#
3212# code: SUN4U-8006-8P
3213# keys: fault.io.hbus fault.io.pci.bus fault.io.tomatillo
3214#
3215msgid "SUN4U-8006-8P.type"
3216msgstr "Fault"
3217msgid "SUN4U-8006-8P.severity"
3218msgstr "Critical"
3219msgid "SUN4U-8006-8P.description"
3220msgstr "\nA problem was detected in a system core bus.\n  Refer to %s for more information."
3221msgid "SUN4U-8006-8P.response"
3222msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
3223msgid "SUN4U-8006-8P.impact"
3224msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
3225msgid "SUN4U-8006-8P.action"
3226msgstr "\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
3227#
3228# code: SUN4U-8006-9A
3229# keys: defect.io.pci.driver fault.io.hbus fault.io.pci.bus fault.io.tomatillo
3230#
3231msgid "SUN4U-8006-9A.type"
3232msgstr "Fault"
3233msgid "SUN4U-8006-9A.severity"
3234msgstr "Critical"
3235msgid "SUN4U-8006-9A.description"
3236msgstr "\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n  Refer to %s for more information."
3237msgid "SUN4U-8006-9A.response"
3238msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
3239msgid "SUN4U-8006-9A.impact"
3240msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
3241msgid "SUN4U-8006-9A.action"
3242msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).  Schedule a repair of the most likely suspect \nlisted in the output.  If the most likely suspect is a package then run \npkgchk on the package(s).\n"
3243#
3244# code: SUN4U-8006-AS
3245# keys: fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.tomatillo
3246#
3247msgid "SUN4U-8006-AS.type"
3248msgstr "Fault"
3249msgid "SUN4U-8006-AS.severity"
3250msgstr "Critical"
3251msgid "SUN4U-8006-AS.description"
3252msgstr "\nA problem was detected in a system core bus.\n  Refer to %s for more information."
3253msgid "SUN4U-8006-AS.response"
3254msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
3255msgid "SUN4U-8006-AS.impact"
3256msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
3257msgid "SUN4U-8006-AS.action"
3258msgstr "\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
3259#
3260# code: SUN4U-8006-C5
3261# keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.tomatillo
3262#
3263msgid "SUN4U-8006-C5.type"
3264msgstr "Fault"
3265msgid "SUN4U-8006-C5.severity"
3266msgstr "Critical"
3267msgid "SUN4U-8006-C5.description"
3268msgstr "\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n  Refer to %s for more information."
3269msgid "SUN4U-8006-C5.response"
3270msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
3271msgid "SUN4U-8006-C5.impact"
3272msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
3273msgid "SUN4U-8006-C5.action"
3274msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).  Schedule a repair of the most likely suspect \nlisted in the output.  If the most likely suspect is a package then run \npkgchk on the package(s).\n"
3275#
3276# code: SUN4U-8006-DY
3277# keys: fault.io.pci.device fault.io.tomatillo
3278#
3279msgid "SUN4U-8006-DY.type"
3280msgstr "Fault"
3281msgid "SUN4U-8006-DY.severity"
3282msgstr "Critical"
3283msgid "SUN4U-8006-DY.description"
3284msgstr "\nA problem was detected in a system core bus.\n  Refer to %s for more information."
3285msgid "SUN4U-8006-DY.response"
3286msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
3287msgid "SUN4U-8006-DY.impact"
3288msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
3289msgid "SUN4U-8006-DY.action"
3290msgstr "\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
3291#
3292# code: SUN4U-8006-E3
3293# keys: defect.io.pci.driver fault.io.pci.device fault.io.tomatillo
3294#
3295msgid "SUN4U-8006-E3.type"
3296msgstr "Fault"
3297msgid "SUN4U-8006-E3.severity"
3298msgstr "Critical"
3299msgid "SUN4U-8006-E3.description"
3300msgstr "\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n  Refer to %s for more information."
3301msgid "SUN4U-8006-E3.response"
3302msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
3303msgid "SUN4U-8006-E3.impact"
3304msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
3305msgid "SUN4U-8006-E3.action"
3306msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).  Schedule a repair of the most likely suspect \nlisted in the output.  If the most likely suspect is a package then run \npkgchk on the package(s).\n"
3307#
3308# code: SUN4U-8006-FH
3309# keys: fault.io.datapath fault.io.pci.device fault.io.tomatillo
3310#
3311msgid "SUN4U-8006-FH.type"
3312msgstr "Fault"
3313msgid "SUN4U-8006-FH.severity"
3314msgstr "Critical"
3315msgid "SUN4U-8006-FH.description"
3316msgstr "\nA problem was detected in a system core bus.\n  Refer to %s for more information."
3317msgid "SUN4U-8006-FH.response"
3318msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
3319msgid "SUN4U-8006-FH.impact"
3320msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
3321msgid "SUN4U-8006-FH.action"
3322msgstr "\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
3323#
3324# code: SUN4U-8006-GD
3325# keys: defect.io.pci.driver fault.io.datapath fault.io.pci.device fault.io.tomatillo
3326#
3327msgid "SUN4U-8006-GD.type"
3328msgstr "Fault"
3329msgid "SUN4U-8006-GD.severity"
3330msgstr "Critical"
3331msgid "SUN4U-8006-GD.description"
3332msgstr "\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n  Refer to %s for more information."
3333msgid "SUN4U-8006-GD.response"
3334msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
3335msgid "SUN4U-8006-GD.impact"
3336msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
3337msgid "SUN4U-8006-GD.action"
3338msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).  Schedule a repair of the most likely suspect \nlisted in the output.  If the most likely suspect is a package then run \npkgchk on the package(s).\n"
3339#
3340# code: SUN4U-8006-HQ
3341# keys: fault.io.hbus fault.io.pci.device fault.io.tomatillo
3342#
3343msgid "SUN4U-8006-HQ.type"
3344msgstr "Fault"
3345msgid "SUN4U-8006-HQ.severity"
3346msgstr "Critical"
3347msgid "SUN4U-8006-HQ.description"
3348msgstr "\nA problem was detected in a system core bus.\n  Refer to %s for more information."
3349msgid "SUN4U-8006-HQ.response"
3350msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
3351msgid "SUN4U-8006-HQ.impact"
3352msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
3353msgid "SUN4U-8006-HQ.action"
3354msgstr "\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
3355#
3356# code: SUN4U-8006-JC
3357# keys: defect.io.pci.driver fault.io.hbus fault.io.pci.device fault.io.tomatillo
3358#
3359msgid "SUN4U-8006-JC.type"
3360msgstr "Fault"
3361msgid "SUN4U-8006-JC.severity"
3362msgstr "Critical"
3363msgid "SUN4U-8006-JC.description"
3364msgstr "\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n  Refer to %s for more information."
3365msgid "SUN4U-8006-JC.response"
3366msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
3367msgid "SUN4U-8006-JC.impact"
3368msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
3369msgid "SUN4U-8006-JC.action"
3370msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).  Schedule a repair of the most likely suspect \nlisted in the output.  If the most likely suspect is a package then run \npkgchk on the package(s).\n"
3371#
3372# code: SUN4U-8006-KR
3373# keys: fault.io.datapath fault.io.hbus fault.io.pci.device fault.io.tomatillo
3374#
3375msgid "SUN4U-8006-KR.type"
3376msgstr "Fault"
3377msgid "SUN4U-8006-KR.severity"
3378msgstr "Critical"
3379msgid "SUN4U-8006-KR.description"
3380msgstr "\nA problem was detected in a system core bus.\n  Refer to %s for more information."
3381msgid "SUN4U-8006-KR.response"
3382msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
3383msgid "SUN4U-8006-KR.impact"
3384msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
3385msgid "SUN4U-8006-KR.action"
3386msgstr "\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
3387#
3388# code: SUN4U-8006-L4
3389# keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.pci.device fault.io.tomatillo
3390#
3391msgid "SUN4U-8006-L4.type"
3392msgstr "Fault"
3393msgid "SUN4U-8006-L4.severity"
3394msgstr "Critical"
3395msgid "SUN4U-8006-L4.description"
3396msgstr "\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n  Refer to %s for more information."
3397msgid "SUN4U-8006-L4.response"
3398msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
3399msgid "SUN4U-8006-L4.impact"
3400msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
3401msgid "SUN4U-8006-L4.action"
3402msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).  Schedule a repair of the most likely suspect \nlisted in the output.  If the most likely suspect is a package then run \npkgchk on the package(s).\n"
3403#
3404# code: SUN4U-8006-MX
3405# keys: fault.io.pci.bus fault.io.pci.device fault.io.tomatillo
3406#
3407msgid "SUN4U-8006-MX.type"
3408msgstr "Fault"
3409msgid "SUN4U-8006-MX.severity"
3410msgstr "Critical"
3411msgid "SUN4U-8006-MX.description"
3412msgstr "\nA problem was detected in a system core bus.\n  Refer to %s for more information."
3413msgid "SUN4U-8006-MX.response"
3414msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
3415msgid "SUN4U-8006-MX.impact"
3416msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
3417msgid "SUN4U-8006-MX.action"
3418msgstr "\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
3419#
3420# code: SUN4U-8006-N2
3421# keys: defect.io.pci.driver fault.io.pci.bus fault.io.pci.device fault.io.tomatillo
3422#
3423msgid "SUN4U-8006-N2.type"
3424msgstr "Fault"
3425msgid "SUN4U-8006-N2.severity"
3426msgstr "Critical"
3427msgid "SUN4U-8006-N2.description"
3428msgstr "\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n  Refer to %s for more information."
3429msgid "SUN4U-8006-N2.response"
3430msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
3431msgid "SUN4U-8006-N2.impact"
3432msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
3433msgid "SUN4U-8006-N2.action"
3434msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).  Schedule a repair of the most likely suspect \nlisted in the output.  If the most likely suspect is a package then run \npkgchk on the package(s).\n"
3435#
3436# code: SUN4U-8006-PJ
3437# keys: fault.io.datapath fault.io.pci.bus fault.io.pci.device fault.io.tomatillo
3438#
3439msgid "SUN4U-8006-PJ.type"
3440msgstr "Fault"
3441msgid "SUN4U-8006-PJ.severity"
3442msgstr "Critical"
3443msgid "SUN4U-8006-PJ.description"
3444msgstr "\nA problem was detected in a system core bus.\n  Refer to %s for more information."
3445msgid "SUN4U-8006-PJ.response"
3446msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
3447msgid "SUN4U-8006-PJ.impact"
3448msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
3449msgid "SUN4U-8006-PJ.action"
3450msgstr "\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
3451#
3452# code: SUN4U-8006-QE
3453# keys: defect.io.pci.driver fault.io.datapath fault.io.pci.bus fault.io.pci.device fault.io.tomatillo
3454#
3455msgid "SUN4U-8006-QE.type"
3456msgstr "Fault"
3457msgid "SUN4U-8006-QE.severity"
3458msgstr "Critical"
3459msgid "SUN4U-8006-QE.description"
3460msgstr "\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n  Refer to %s for more information."
3461msgid "SUN4U-8006-QE.response"
3462msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
3463msgid "SUN4U-8006-QE.impact"
3464msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
3465msgid "SUN4U-8006-QE.action"
3466msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).  Schedule a repair of the most likely suspect \nlisted in the output.  If the most likely suspect is a package then run \npkgchk on the package(s).\n"
3467#
3468# code: SUN4U-8006-R5
3469# keys: fault.io.hbus fault.io.pci.bus fault.io.pci.device fault.io.tomatillo
3470#
3471msgid "SUN4U-8006-R5.type"
3472msgstr "Fault"
3473msgid "SUN4U-8006-R5.severity"
3474msgstr "Critical"
3475msgid "SUN4U-8006-R5.description"
3476msgstr "\nA problem was detected in a system core bus.\n  Refer to %s for more information."
3477msgid "SUN4U-8006-R5.response"
3478msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
3479msgid "SUN4U-8006-R5.impact"
3480msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
3481msgid "SUN4U-8006-R5.action"
3482msgstr "\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
3483#
3484# code: SUN4U-8006-SS
3485# keys: defect.io.pci.driver fault.io.hbus fault.io.pci.bus fault.io.pci.device fault.io.tomatillo
3486#
3487msgid "SUN4U-8006-SS.type"
3488msgstr "Fault"
3489msgid "SUN4U-8006-SS.severity"
3490msgstr "Critical"
3491msgid "SUN4U-8006-SS.description"
3492msgstr "\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n  Refer to %s for more information."
3493msgid "SUN4U-8006-SS.response"
3494msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
3495msgid "SUN4U-8006-SS.impact"
3496msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
3497msgid "SUN4U-8006-SS.action"
3498msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).  Schedule a repair of the most likely suspect \nlisted in the output.  If the most likely suspect is a package then run \npkgchk on the package(s).\n"
3499#
3500# code: SUN4U-8006-TA
3501# keys: fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.pci.device fault.io.tomatillo
3502#
3503msgid "SUN4U-8006-TA.type"
3504msgstr "Fault"
3505msgid "SUN4U-8006-TA.severity"
3506msgstr "Critical"
3507msgid "SUN4U-8006-TA.description"
3508msgstr "\nA problem was detected in a system core bus.\n  Refer to %s for more information."
3509msgid "SUN4U-8006-TA.response"
3510msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
3511msgid "SUN4U-8006-TA.impact"
3512msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
3513msgid "SUN4U-8006-TA.action"
3514msgstr "\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
3515#
3516# code: SUN4U-8006-UP
3517# keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.pci.device fault.io.tomatillo
3518#
3519msgid "SUN4U-8006-UP.type"
3520msgstr "Fault"
3521msgid "SUN4U-8006-UP.severity"
3522msgstr "Critical"
3523msgid "SUN4U-8006-UP.description"
3524msgstr "\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n  Refer to %s for more information."
3525msgid "SUN4U-8006-UP.response"
3526msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
3527msgid "SUN4U-8006-UP.impact"
3528msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
3529msgid "SUN4U-8006-UP.action"
3530msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).  Schedule a repair of the most likely suspect \nlisted in the output.  If the most likely suspect is a package then run \npkgchk on the package(s).\n"
3531#
3532# code: SUN4U-8006-VD
3533# keys: fault.cpu.ultraSPARC-IIIiplus.dcache
3534#
3535msgid "SUN4U-8006-VD.type"
3536msgstr "Fault"
3537msgid "SUN4U-8006-VD.severity"
3538msgstr "Major"
3539msgid "SUN4U-8006-VD.description"
3540msgstr "The number of errors associated with a CPU has exceeded acceptable levels.  Refer to %s for more information."
3541msgid "SUN4U-8006-VD.response"
3542msgstr "The fault manager will attempt to remove the affected CPU from service."
3543msgid "SUN4U-8006-VD.impact"
3544msgstr "System performance may be affected."
3545msgid "SUN4U-8006-VD.action"
3546msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>."
3547#
3548# code: SUN4U-8006-WH
3549# keys: fault.cpu.ultraSPARC-IIIiplus.icache
3550#
3551msgid "SUN4U-8006-WH.type"
3552msgstr "Fault"
3553msgid "SUN4U-8006-WH.severity"
3554msgstr "Major"
3555msgid "SUN4U-8006-WH.description"
3556msgstr "The number of errors associated with a CPU has exceeded acceptable levels.  Refer to %s for more information."
3557msgid "SUN4U-8006-WH.response"
3558msgstr "The fault manager will attempt to remove the affected CPU from service."
3559msgid "SUN4U-8006-WH.impact"
3560msgstr "System performance may be affected."
3561msgid "SUN4U-8006-WH.action"
3562msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>."
3563#
3564# code: SUN4U-8006-X3
3565# keys: fault.cpu.ultraSPARC-IIIiplus.l2cachedata
3566#
3567msgid "SUN4U-8006-X3.type"
3568msgstr "Fault"
3569msgid "SUN4U-8006-X3.severity"
3570msgstr "Major"
3571msgid "SUN4U-8006-X3.description"
3572msgstr "The number of errors associated with a CPU has exceeded acceptable levels.  Refer to %s for more information."
3573msgid "SUN4U-8006-X3.response"
3574msgstr "The fault manager will attempt to remove the affected CPU from service."
3575msgid "SUN4U-8006-X3.impact"
3576msgstr "System performance may be affected."
3577msgid "SUN4U-8006-X3.action"
3578msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>."
3579#
3580# code: SUN4U-8006-YY
3581# keys: fault.cpu.ultraSPARC-IIIiplus.l2cachetag
3582#
3583msgid "SUN4U-8006-YY.type"
3584msgstr "Fault"
3585msgid "SUN4U-8006-YY.severity"
3586msgstr "Major"
3587msgid "SUN4U-8006-YY.description"
3588msgstr "The number of errors associated with a CPU has exceeded acceptable levels.  Refer to %s for more information."
3589msgid "SUN4U-8006-YY.response"
3590msgstr "The fault manager will attempt to remove the affected CPU from service."
3591msgid "SUN4U-8006-YY.impact"
3592msgstr "System performance may be affected."
3593msgid "SUN4U-8006-YY.action"
3594msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>."
3595#
3596# code: SUN4U-8007-03
3597# keys: fault.cpu.ultraSPARC-IIIiplus.fpu
3598#
3599msgid "SUN4U-8007-03.type"
3600msgstr "Fault"
3601msgid "SUN4U-8007-03.severity"
3602msgstr "Major"
3603msgid "SUN4U-8007-03.description"
3604msgstr "The number of errors associated with a CPU has exceeded acceptable levels.  Refer to %s for more information."
3605msgid "SUN4U-8007-03.response"
3606msgstr "The fault manager will attempt to remove the affected CPU from service."
3607msgid "SUN4U-8007-03.impact"
3608msgstr "System performance may be affected."
3609msgid "SUN4U-8007-03.action"
3610msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>."
3611#
3612# code: SUN4U-8007-1Y
3613# keys: fault.asic.cds.dp
3614#
3615msgid "SUN4U-8007-1Y.type"
3616msgstr "Fault"
3617msgid "SUN4U-8007-1Y.severity"
3618msgstr "Critical"
3619msgid "SUN4U-8007-1Y.description"
3620msgstr "A hardware problem was detected on the datapath interconnect.\n  Refer to %s for more information."
3621msgid "SUN4U-8007-1Y.response"
3622msgstr "One or more CPUs may be offlined. Additionally, page retires for memory in the impacted region may be disabled.\n"
3623msgid "SUN4U-8007-1Y.impact"
3624msgstr "System performace may be affected.\n"
3625msgid "SUN4U-8007-1Y.action"
3626msgstr "Schedule a repair procedure to replace the affected component(s). The System Controller (SC) diagnostic messages have the authoritative information on the affected component(s). fmdump -v -u <EVENT-ID> can also be used, but the SC is authoritative.\n"
3627#
3628# code: SUN4U-8007-2D
3629# keys: fault.asic.dx.dp
3630#
3631msgid "SUN4U-8007-2D.type"
3632msgstr "Fault"
3633msgid "SUN4U-8007-2D.severity"
3634msgstr "Critical"
3635msgid "SUN4U-8007-2D.description"
3636msgstr "A hardware problem was detected on the datapath interconnect.\n  Refer to %s for more information."
3637msgid "SUN4U-8007-2D.response"
3638msgstr "One or more CPUs may be offlined. Additionally, page retires for memory in the impacted region may be disabled.\n"
3639msgid "SUN4U-8007-2D.impact"
3640msgstr "System performace may be affected.\n"
3641msgid "SUN4U-8007-2D.action"
3642msgstr "Schedule a repair procedure to replace the affected component(s). The System Controller (SC) diagnostic messages have the authoritative information on the affected component(s). fmdump -v -u <EVENT-ID> can also be used, but the SC is authoritative.\n"
3643#
3644# code: SUN4U-8007-3H
3645# keys: fault.asic.sdi.dp
3646#
3647msgid "SUN4U-8007-3H.type"
3648msgstr "Fault"
3649msgid "SUN4U-8007-3H.severity"
3650msgstr "Critical"
3651msgid "SUN4U-8007-3H.description"
3652msgstr "A hardware problem was detected on the datapath interconnect.\n  Refer to %s for more information."
3653msgid "SUN4U-8007-3H.response"
3654msgstr "One or more CPUs may be offlined. Additionally, page retires for memory in the impacted region may be disabled.\n"
3655msgid "SUN4U-8007-3H.impact"
3656msgstr "System performace may be affected.\n"
3657msgid "SUN4U-8007-3H.action"
3658msgstr "Schedule a repair procedure to replace the affected component(s). The System Controller (SC) diagnostic messages have the authoritative information on the affected component(s). fmdump -v -u <EVENT-ID> can also be used, but the SC is authoritative.\n"
3659#
3660# code: SUN4U-8007-4A
3661# keys: fault.asic.cp.dp
3662#
3663msgid "SUN4U-8007-4A.type"
3664msgstr "Fault"
3665msgid "SUN4U-8007-4A.severity"
3666msgstr "Critical"
3667msgid "SUN4U-8007-4A.description"
3668msgstr "A hardware problem was detected on the datapath interconnect.\n  Refer to %s for more information."
3669msgid "SUN4U-8007-4A.response"
3670msgstr "One or more CPUs may be offlined. Additionally, page retires for memory in the impacted region may be disabled.\n"
3671msgid "SUN4U-8007-4A.impact"
3672msgstr "System performace may be affected.\n"
3673msgid "SUN4U-8007-4A.action"
3674msgstr "Schedule a repair procedure to replace the affected component(s). The System Controller (SC) diagnostic messages have the authoritative information on the affected component(s). fmdump -v -u <EVENT-ID> can also be used, but the SC is authoritative.\n"
3675#
3676# code: SUN4U-8007-5P
3677# keys: fault.asic.rp.dp
3678#
3679msgid "SUN4U-8007-5P.type"
3680msgstr "Fault"
3681msgid "SUN4U-8007-5P.severity"
3682msgstr "Critical"
3683msgid "SUN4U-8007-5P.description"
3684msgstr "A hardware problem was detected on the datapath interconnect.\n  Refer to %s for more information."
3685msgid "SUN4U-8007-5P.response"
3686msgstr "One or more CPUs may be offlined. Additionally, page retires for memory in the impacted region may be disabled.\n"
3687msgid "SUN4U-8007-5P.impact"
3688msgstr "System performace may be affected.\n"
3689msgid "SUN4U-8007-5P.action"
3690msgstr "Schedule a repair procedure to replace the affected component(s). The System Controller (SC) diagnostic messages have the authoritative information on the affected component(s). fmdump -v -u <EVENT-ID> can also be used, but the SC is authoritative.\n"
3691#
3692# code: SUN4U-8007-65
3693# keys: fault.io.oberon
3694#
3695msgid "SUN4U-8007-65.type"
3696msgstr "Fault"
3697msgid "SUN4U-8007-65.severity"
3698msgstr "Critical"
3699msgid "SUN4U-8007-65.description"
3700msgstr "Oberon PCI-Express hostbridge fault\n  Refer to %s for more information."
3701msgid "SUN4U-8007-65.response"
3702msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
3703msgid "SUN4U-8007-65.impact"
3704msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
3705msgid "SUN4U-8007-65.action"
3706msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
3707#
3708# code: SUN4U-8007-7S
3709# keys: fault.cpu.SPARC64-VI.chip
3710#
3711msgid "SUN4U-8007-7S.type"
3712msgstr "Fault"
3713msgid "SUN4U-8007-7S.severity"
3714msgstr "Critical"
3715msgid "SUN4U-8007-7S.description"
3716msgstr "The number of errors associated with this CHIP has exceeded acceptable levels.  Refer to %s for more information."
3717msgid "SUN4U-8007-7S.response"
3718msgstr "An attempt will be made to remove the affected CHIP from service."
3719msgid "SUN4U-8007-7S.impact"
3720msgstr "The system will not be functioning at the same performance level with the CHIP removal."
3721msgid "SUN4U-8007-7S.action"
3722msgstr "Schedule a repair procedure to replace the affected CHIP.  Use fmdump -v -u <EVENT_ID>\nto identify the smallest CPU/Strand ID of the affected CORE on this\nCHIP."
3723#
3724# code: SUN4U-8007-8J
3725# keys: fault.cpu.SPARC64-VI.core
3726#
3727msgid "SUN4U-8007-8J.type"
3728msgstr "Fault"
3729msgid "SUN4U-8007-8J.severity"
3730msgstr "Critical"
3731msgid "SUN4U-8007-8J.description"
3732msgstr "The number of errors associated with this CORE has exceeded acceptable levels.  Refer to %s for more information."
3733msgid "SUN4U-8007-8J.response"
3734msgstr "An attempt will be made to remove the affected CORE from service."
3735msgid "SUN4U-8007-8J.impact"
3736msgstr "The system will not be functioning at the same performance level with the CORE removal."
3737msgid "SUN4U-8007-8J.action"
3738msgstr "Schedule a repair procedure to replace the affected CORE.  Use fmdump -v -u <EVENT_ID>\nto identify the smallest CPU/Strand ID of the affected CORE on this\nCORE.\n"
3739#
3740# code: SUN4U-8007-9E
3741# keys: fault.cpu.SPARC64-VI.strand
3742#
3743msgid "SUN4U-8007-9E.type"
3744msgstr "Fault"
3745msgid "SUN4U-8007-9E.severity"
3746msgstr "Critical"
3747msgid "SUN4U-8007-9E.description"
3748msgstr "The number of errors associated with this STRAND has exceeded acceptable levels.  Refer to %s for more information."
3749msgid "SUN4U-8007-9E.response"
3750msgstr "An attempt will be made to remove the affected STRAND from service."
3751msgid "SUN4U-8007-9E.impact"
3752msgstr "The system will not be functioning at the same performance level with the STRAND removal."
3753msgid "SUN4U-8007-9E.action"
3754msgstr "Schedule a repair procedure to replace the affected STRAND.  Use fmdump -v -u <EVENT_ID>\nto identify the smallest CPU/Strand ID of the affected CORE on this\nSTRAND.\n"
3755#
3756# code: SUN4U-8007-AX
3757# keys: fault.io.pci.device-invreq fault.io.tomatillo
3758#
3759msgid "SUN4U-8007-AX.type"
3760msgstr "Fault"
3761msgid "SUN4U-8007-AX.severity"
3762msgstr "Critical"
3763msgid "SUN4U-8007-AX.description"
3764msgstr "Either the transmitting device sent an invalid request or the receiving device failed to respond.\n  Refer to %s for more information."
3765msgid "SUN4U-8007-AX.response"
3766msgstr "One or more device instances may be disabled\n"
3767msgid "SUN4U-8007-AX.impact"
3768msgstr "Loss of services provided by the device instances associated with this fault\n"
3769msgid "SUN4U-8007-AX.action"
3770msgstr "Ensure that the latest drivers and patches are installed. If a plug-in card is involved check for badly-seated cards or bent pins.  Otherwise schedule a repair procedure to replace the affected device(s).  Use fmdump -v -u <EVENT_ID> to identify the devices or contact Sun for support.\n"
3771#
3772# code: SUN4U-8007-C2
3773# keys: fault.cpu.SPARC64-VII.chip
3774#
3775msgid "SUN4U-8007-C2.type"
3776msgstr "Fault"
3777msgid "SUN4U-8007-C2.severity"
3778msgstr "Critical"
3779msgid "SUN4U-8007-C2.description"
3780msgstr "The number of errors associated with this CHIP has exceeded acceptable levels.  Refer to %s for more information."
3781msgid "SUN4U-8007-C2.response"
3782msgstr "An attempt will be made to remove the affected CHIP from service."
3783msgid "SUN4U-8007-C2.impact"
3784msgstr "The system will not be functioning at the same performance level with the CHIP removal."
3785msgid "SUN4U-8007-C2.action"
3786msgstr "Schedule a repair procedure to replace the affected CHIP.  Use fmdump -v -u <EVENT_ID>\nto identify the smallest CPU/Strand ID of the affected CORE on this\nCHIP."
3787#
3788# code: SUN4U-8007-DR
3789# keys: fault.cpu.SPARC64-VII.core
3790#
3791msgid "SUN4U-8007-DR.type"
3792msgstr "Fault"
3793msgid "SUN4U-8007-DR.severity"
3794msgstr "Critical"
3795msgid "SUN4U-8007-DR.description"
3796msgstr "The number of errors associated with this CORE has exceeded acceptable levels.  Refer to %s for more information."
3797msgid "SUN4U-8007-DR.response"
3798msgstr "An attempt will be made to remove the affected CORE from service."
3799msgid "SUN4U-8007-DR.impact"
3800msgstr "The system will not be functioning at the same performance level with the CORE removal."
3801msgid "SUN4U-8007-DR.action"
3802msgstr "Schedule a repair procedure to replace the affected CORE.  Use fmdump -v -u <EVENT_ID>\nto identify the smallest CPU/Strand ID of the affected CORE on this\nCORE.\n"
3803#
3804# code: SUN4U-8007-E4
3805# keys: fault.cpu.SPARC64-VII.strand
3806#
3807msgid "SUN4U-8007-E4.type"
3808msgstr "Fault"
3809msgid "SUN4U-8007-E4.severity"
3810msgstr "Critical"
3811msgid "SUN4U-8007-E4.description"
3812msgstr "The number of errors associated with this STRAND has exceeded acceptable levels.  Refer to %s for more information."
3813msgid "SUN4U-8007-E4.response"
3814msgstr "An attempt will be made to remove the affected STRAND from service."
3815msgid "SUN4U-8007-E4.impact"
3816msgstr "The system will not be functioning at the same performance level with the STRAND removal."
3817msgid "SUN4U-8007-E4.action"
3818msgstr "Schedule a repair procedure to replace the affected STRAND.  Use fmdump -v -u <EVENT_ID>\nto identify the smallest CPU/Strand ID of the affected CORE on this\nSTRAND.\n"
3819#
3820# code: SUN4U-8007-FQ
3821# keys: fault.cpu.ultraSPARC-IVplus.l2cachedata-line
3822#
3823msgid "SUN4U-8007-FQ.type"
3824msgstr "Fault"
3825msgid "SUN4U-8007-FQ.severity"
3826msgstr "Minor"
3827msgid "SUN4U-8007-FQ.description"
3828msgstr "The Solaris Fault Manager has determined that the\nnumber of correctable errors against a\nparticular CPU's cache index and way exceeds recommended\nlimts.\n  Refer to %s for more information."
3829msgid "SUN4U-8007-FQ.response"
3830msgstr "The system will attempt to remove the CPU's offending\ncache index and way from service.\n"
3831msgid "SUN4U-8007-FQ.impact"
3832msgstr "The performace of the system may be minimally impacted as\na result of removing the cache line and way from service.\nLoss of service will be limited to this CPU's cache\nline and way.\n"
3833msgid "SUN4U-8007-FQ.action"
3834msgstr "No repair action is recommended at this time.\n"
3835#
3836# code: SUN4U-8007-GC
3837# keys: fault.cpu.ultraSPARC-IVplus.l3cachedata-line
3838#
3839msgid "SUN4U-8007-GC.type"
3840msgstr "Fault"
3841msgid "SUN4U-8007-GC.severity"
3842msgstr "Minor"
3843msgid "SUN4U-8007-GC.description"
3844msgstr "The Solaris Fault Manager has determined that the\nnumber of correctable errors against a\nparticular CPU's cache index and way exceeds recommended\nlimts.\n  Refer to %s for more information."
3845msgid "SUN4U-8007-GC.response"
3846msgstr "The system will attempt to remove the CPU's offending\ncache index and way from service.\n"
3847msgid "SUN4U-8007-GC.impact"
3848msgstr "The performace of the system may be minimally impacted as\na result of removing the cache line and way from service.\nLoss of service will be limited to this CPU's cache\nline and way.\n"
3849msgid "SUN4U-8007-GC.action"
3850msgstr "No repair action is recommended at this time.\n"
3851#
3852# code: SUN4U-8007-HH
3853# keys: fault.cpu.ultraSPARC-IVplus.l2cachetag-line
3854#
3855msgid "SUN4U-8007-HH.type"
3856msgstr "Fault"
3857msgid "SUN4U-8007-HH.severity"
3858msgstr "Minor"
3859msgid "SUN4U-8007-HH.description"
3860msgstr "The Solaris Fault Manager has determined that the\nnumber of correctable errors against a\nparticular CPU's cache index and way exceeds recommended\nlimts.\n  Refer to %s for more information."
3861msgid "SUN4U-8007-HH.response"
3862msgstr "The system will attempt to remove the CPU's offending\ncache index and way from service.\n"
3863msgid "SUN4U-8007-HH.impact"
3864msgstr "The performace of the system may be minimally impacted as\na result of removing the cache line and way from service.\nLoss of service will be limited to this CPU's cache\nline and way.\n"
3865msgid "SUN4U-8007-HH.action"
3866msgstr "No repair action is recommended at this time.\n"
3867#
3868# code: SUN4U-8007-JD
3869# keys: fault.cpu.ultraSPARC-IVplus.l3cachetag-line
3870#
3871msgid "SUN4U-8007-JD.type"
3872msgstr "Fault"
3873msgid "SUN4U-8007-JD.severity"
3874msgstr "Minor"
3875msgid "SUN4U-8007-JD.description"
3876msgstr "The Solaris Fault Manager has determined that the\nnumber of correctable errors against a\nparticular CPU's cache index and way exceeds recommended\nlimts.\n  Refer to %s for more information."
3877msgid "SUN4U-8007-JD.response"
3878msgstr "The system will attempt to remove the CPU's offending\ncache index and way from service.\n"
3879msgid "SUN4U-8007-JD.impact"
3880msgstr "The performace of the system may be minimally impacted as\na result of removing the cache line and way from service.\nLoss of service will be limited to this CPU's cache\nline and way.\n"
3881msgid "SUN4U-8007-JD.action"
3882msgstr "No repair action is recommended at this time.\n"
3883#
3884# code: SUN4U-8007-KY
3885# keys: fault.memory.dimm-page-retires-excessive
3886#
3887msgid "SUN4U-8007-KY.type"
3888msgstr "Fault"
3889msgid "SUN4U-8007-KY.severity"
3890msgstr "Major"
3891msgid "SUN4U-8007-KY.description"
3892msgstr "The number of correctable errors associated with this memory module has exceeded acceptable levels.\n  Refer to %s for more information."
3893msgid "SUN4U-8007-KY.response"
3894msgstr "Pages of memory associated with this memory module have been removed from service, up to a limit which has now been reached.\n"
3895msgid "SUN4U-8007-KY.impact"
3896msgstr "Total system memory capacity has been reduced.\n"
3897msgid "SUN4U-8007-KY.action"
3898msgstr "Schedule a repair procedure to replace the DIMM. Use fmadm faulty to identify the DIMM to replace.\n"
3899#
3900# code: SUN4U-8007-L3
3901# keys: fault.memory.dimm-ue-imminent
3902#
3903msgid "SUN4U-8007-L3.type"
3904msgstr "Fault"
3905msgid "SUN4U-8007-L3.severity"
3906msgstr "Critical"
3907msgid "SUN4U-8007-L3.description"
3908msgstr "A pattern of correctable errors has been observed suggesting the potential exists that an uncorrectable error may occur.\n  Refer to %s for more information."
3909msgid "SUN4U-8007-L3.response"
3910msgstr "None at this time.\n"
3911msgid "SUN4U-8007-L3.impact"
3912msgstr "None at this time. However, the potential uncorrectable error warrants proactive service action to avoid any unplanned system outages.\n"
3913msgid "SUN4U-8007-L3.action"
3914msgstr "Schedule a repair procedure to replace the DIMM. Use fmadm faulty to identify the DIMM to replace.\n"
3915#
3916# code: SUN4U-8007-MS
3917# keys: fault.memory.dram-ue-imminent
3918#
3919msgid "SUN4U-8007-MS.type"
3920msgstr "Fault"
3921msgid "SUN4U-8007-MS.severity"
3922msgstr "Critical"
3923msgid "SUN4U-8007-MS.description"
3924msgstr "A pattern of correctable errors has been observed suggesting the potential exists that an uncorrectable error may occur.\n  Refer to %s for more information."
3925msgid "SUN4U-8007-MS.response"
3926msgstr "None at this time.\n"
3927msgid "SUN4U-8007-MS.impact"
3928msgstr "None at this time. However, the potential uncorrectable error warrants proactive service action to avoid any unplanned system outages.\n"
3929msgid "SUN4U-8007-MS.action"
3930msgstr "Schedule a repair procedure to replace the DIMM. Use fmadm faulty to identify the DIMM to replace.\n"
3931