xref: /titanic_44/usr/src/uts/sun4u/starcat/sys/schpc_msg.h (revision 3db86aab554edbb4244c8d1a1c90f152eee768af)
1 /*
2  * CDDL HEADER START
3  *
4  * The contents of this file are subject to the terms of the
5  * Common Development and Distribution License (the "License").
6  * You may not use this file except in compliance with the License.
7  *
8  * You can obtain a copy of the license at usr/src/OPENSOLARIS.LICENSE
9  * or http://www.opensolaris.org/os/licensing.
10  * See the License for the specific language governing permissions
11  * and limitations under the License.
12  *
13  * When distributing Covered Code, include this CDDL HEADER in each
14  * file and include the License file at usr/src/OPENSOLARIS.LICENSE.
15  * If applicable, add the following below this CDDL HEADER, with the
16  * fields enclosed by brackets "[]" replaced with your own identifying
17  * information: Portions Copyright [yyyy] [name of copyright owner]
18  *
19  * CDDL HEADER END
20  */
21 
22 /*
23  * Copyright 2005 Sun Microsystems, Inc.  All rights reserved.
24  * Use is subject to license terms.
25  */
26 
27 #ifndef _SYS_SCHPC_MSG_H
28 #define	_SYS_SCHPC_MSG_H
29 
30 #pragma ident	"%Z%%M%	%I%	%E% SMI"
31 
32 /*
33  * This header file describes the messages that are sent between the
34  * schpc Hot Plug Controller Driver running on the domain and the System
35  * Controller.
36  */
37 
38 #ifdef	__cplusplus
39 extern "C" {
40 #endif
41 
42 /*
43  * Format of the Get Slot Status specific part of
44  * PCI Hot Plug message.
45  */
46 typedef struct {
47 	uint16_t	slot_power_on 		:1, /* Slot Power is on */
48 			slot_powergood		:1, /* Slot Power is good */
49 			slot_powerfault		:1, /* Slot Power has faulted */
50 			slot_empty		:1, /* No occupant in slot */
51 			slot_freq_cap		:2, /* Slot's Freq Capability */
52 			slot_freq_setting	:2, /* Slot Freq setting */
53 			slot_condition		:2, /* Condition of slot */
54 			slot_HEALTHY		:1, /* Value of HEALTHY# sig */
55 			slot_ENUM		:1, /* Value of ENUM# sig */
56 			slot_mode_cap		:1, /* Conven or PCI-X */
57 			slot_mode_setting	:1, /* Conven or PCI-X */
58 			reserved		:2;
59 	uint8_t		slot_replystatus;
60 } pci_getslot_t;
61 
62 /*
63  * Format of the Set Slot Status specific part of
64  * PCI Hot Plug message.
65  */
66 typedef struct {
67 	uint16_t	slot_power_on		:1, /* Connect Slot to bus */
68 			slot_power_off		:1, /* Disconnect from bus */
69 			slot_led_power		:2, /* Slot Power LED */
70 			slot_led_service	:2, /* OK To Remove LED */
71 			slot_led_fault		:2, /* Fault LED */
72 			slot_disable_ENUM	:1, /* Disable ENUM Event */
73 			slot_enable_ENUM	:1, /* Enable ENUM Event */
74 			slot_disable_HEALTHY	:1, /* Disable HEALTHY EVENT */
75 			slot_enable_HEALTHY	:1, /* Enable HEALTHY EVENT */
76 			reserved		:4;
77 	uint8_t		slot_replystatus;
78 } pci_setslot_t;
79 
80 /*
81  * Format of the Slot Event specific part of
82  * the PCI Hot Plug message.
83  */
84 typedef struct {
85 	uint16_t	slot_power		:1, /* Slot Power has changed */
86 			slot_presence		:1, /* occupant has been    */
87 						    /* inserted or removed  */
88 			slot_ENUM		:1, /* ENUM# has changed */
89 			slot_HEALTHY		:1, /* HEALTHY# has changed */
90 			slot_powergood		:1, /* Power is good */
91 			slot_powerfault		:1, /* Power has faulted */
92 			reserved		:10;
93 } pci_slotevent_t;
94 
95 /*
96  * PCI Hot Plug message
97  */
98 typedef struct {
99 	uint8_t		pcimsg_node;
100 	uint8_t		pcimsg_board;
101 	uint8_t		pcimsg_slot;
102 	uint8_t		pcimsg_revision;
103 	uint8_t		pcimsg_command;
104 	union {
105 		pci_setslot_t	pcimsg_setslot;
106 		pci_getslot_t	pcimsg_getslot;
107 		pci_slotevent_t	pcimsg_slotevent;
108 	} pcimsg_type;
109 } pcimsg_t;
110 
111 /*
112  * Keys for the outgoing and incoming mailboxes
113  */
114 #define	KEY_PCSC	0x50435343	/* Outgoing Mailbox 'PCSC' */
115 #define	KEY_SCPC	0x53435043	/* Incoming Mailbox 'SCPC' */
116 
117 /*
118  * default timeout in seconds for mboxsc_getmsg calls
119  */
120 #define	PCSC_TIMEOUT	30
121 
122 /* Commands */
123 #define	PCIMSG_GETSLOTSTATUS	0x1
124 #define	PCIMSG_SETSLOTSTATUS	0x2
125 #define	PCIMSG_SLOTEVENT	0x3
126 
127 /* Message Revisions */
128 #define	PCIMSG_REVISION		0x10
129 #define	PCIMSG_REVISION_1_0	0x10
130 
131 /*
132  * Values for the slot_condition field of the get slot status command.
133  */
134 #define	PCIMSG_SLOTCOND_UNKNOWN		0x0
135 #define	PCIMSG_SLOTCOND_GOOD		0x1
136 #define	PCIMSG_SLOTCOND_REC_FAIL	0x2
137 #define	PCIMSG_SLOTCOND_OCC_FAIL	0x3
138 #define	PCIMSG_SLOTCOND_NOHOTPLUG	0x4
139 
140 /*
141  * Values for the slot_freq_cap and slot_freq_setting fields of the get
142  * slot status command.
143  */
144 #define	PCIMSG_FREQ_33MHZ	0x0
145 #define	PCIMSG_FREQ_66MHZ	0x1
146 #define	PCIMSG_FREQ_90MHZ	0x2
147 #define	PCIMSG_FREQ_133MHZ	0x3
148 
149 /*
150  * Values for the slot_mode_cap and slot_mode_setting of the get
151  * slot status command.
152  */
153 #define	PCIMSG_MODE_CONVEN	0x0
154 #define	PCIMSG_MODE_PCIX	0x1
155 
156 /*
157  * Values for the PRSNT signals.
158  */
159 #define	PCIMSG_PRSNT_NOADAPTER	0x0
160 #define	PCIMSG_PRSNT_25W	0x1
161 #define	PCIMSG_PRSNT_15W	0x2
162 #define	PCIMSG_PRSNT_7_5W	0x3
163 
164 /*
165  * Values to turn on and off slot characteristics.
166  */
167 #define	PCIMSG_ON		0x1
168 #define	PCIMSG_OFF		0x0
169 
170 /*
171  * Values to set the power, service and fault LEDs
172  */
173 #define	PCIMSG_LED_OFF		0x00
174 #define	PCIMSG_LED_ON		0x01
175 #define	PCIMSG_LED_FLASH	0x02
176 
177 /*
178  * Return values for the slot_replystatus field for the get/set slot status
179  * commands.
180  */
181 #define	PCIMSG_REPLY_GOOD	0x0
182 #define	PCIMSG_REPLY_FAIL	0x1
183 
184 #ifdef __cplusplus
185 }
186 #endif
187 
188 #endif /* _SYS_SCHPC_MSG_H */
189