xref: /titanic_44/usr/src/man/man3head/siginfo.h.3head (revision db8b037b5616a366b7dfdc01ef9552f02f9adfdd)
te
Copyright (c) 2008, Sun Microsystems, Inc. All Rights Reserved.
Copyright 1989 AT&T
The contents of this file are subject to the terms of the Common Development and Distribution License (the "License"). You may not use this file except in compliance with the License.
You can obtain a copy of the license at usr/src/OPENSOLARIS.LICENSE or http://www.opensolaris.org/os/licensing. See the License for the specific language governing permissions and limitations under the License.
When distributing Covered Code, include this CDDL HEADER in each file and include the License file at usr/src/OPENSOLARIS.LICENSE. If applicable, add the following below this CDDL HEADER, with the fields enclosed by brackets "[]" replaced with your own identifying information: Portions Copyright [yyyy] [name of copyright owner]
SIGINFO.H 3HEAD "Feb 5, 2008"
NAME
siginfo.h, siginfo - signal generation information
SYNOPSIS

#include <siginfo.h>
DESCRIPTION

If a process is catching a signal, it might request information that tells why the system generated that signal. See sigaction(2). If a process is monitoring its children, it might receive information that tells why a child changed state. See waitid(2). In either case, the system returns the information in a structure of type siginfo_t, which includes the following information:

int si_signo /* signal number */
int si_errno /* error number */
int si_code /* signal code */
union sigval si_value /* signal value */

si_signo contains the system-generated signal number. For the waitid(2) function, si_signo is always SIGCHLD.

If si_errno is non-zero, it contains an error number associated with this signal, as defined in <errno.h>.

si_code contains a code identifying the cause of the signal.

If the value of the si_code member is SI_NOINFO, only the si_signo member of siginfo_t is meaningful, and the value of all other members is unspecified.

"User Signals"

If the value of si_code is less than or equal to 0, then the signal was generated by a user process (see kill(2), _lwp_kill(2), sigqueue(3C), sigsend(2), abort(3C), and raise(3C)) and the siginfo structure contains the following additional information:

pid_t si_pid /* sending process ID */
uid_t si_uid /* sending user ID */
ctid_t si_ctid /* sending contract ID */
zoneid_t si_zoneid /* sending zone ID */S

If the signal was generated by a user process, the following values are defined for si_code: SI_USER

The implementation sets si_code to SI_USER if the signal was sent by kill(2), sigsend(2), raise(3C) or abort(3C).

SI_LWP

The signal was sent by _lwp_kill(2).

SI_QUEUE

The signal was sent by sigqueue(3C).

SI_TIMER

The signal was generated by the expiration of a timer created by timer_settime(3C).

SI_ASYNCIO

The signal was generated by the completion of an asynchronous I/O request.

SI_MESGQ

The signal was generated by the arrival of a message on an empty message queue. See mq_notify(3C).

si_value contains the application specified value, which is passed to the application's signal-catching function at the time of the signal delivery if si_code is any of SI_QUEUE, SI_TIMER, SI_ASYNCHIO, or SI_MESGQ.

"System Signals"

Non-user generated signals can arise for a number of reasons. For all of these cases, si_code contains a positive value reflecting the reason why the system generated the signal:

Signal Code Reason
SIGILL ILL_ILLOPC illegal opcode
ILL_ILLOPN illegal operand
ILL_ILLADR illegal addressing mode
ILL_ILLTRP illegal trap
ILL_PRVOPC privileged opcode
ILL_PRVREG privileged register
ILL_COPROC co-processor error
ILL_BADSTK internal stack error
SIGFPE FPE_INTDIV integer divide by zero
FPE_INTOVF integer overflow
FPE_FLTDIV floating point divide by zero
FPE_FLTOVF floating point overflow
FPE_FLTUND floating point underflow
FPE_FLTRES floating point inexact result
FPE_FLTINV invalid floating point operation
FPE_FLTSUB subscript out of range
SIGSEGV SEGV_MAPERR address not mapped to object
SEGV_ACCERR invalid permissions for mapped object
SIGBUS BUS_ADRALN invalid address alignment
BUS_ADRERR non-existent physical address
BUS_OBJERR object specific hardware error
SIGTRAP TRAP_BRKPT process breakpoint
TRAP_TRACE process trace trap
SIGCHLD CLD_EXITED child has exited
CLD_KILLED child was killed
CLD_DUMPED child terminated abnormally
CLD_TRAPPED traced child has trapped
CLD_STOPPED child has stopped
CLD_CONTINUED stopped child had continued
SIGPOLL POLL_IN data input available
POLL_OUT output buffers available
POLL_MSG input message available
POLL_ERR I/O error
POLL_PRI high priority input available
POLL_HUP device disconnected

Signals can also be generated from the resource control subsystem. Where these signals do not already possess kernel-level siginfo codes, the siginfo si_code will be filled with SI_RCTL to indicate a kernel-generated signal from an established resource control value.

Signal Code Reason
SIGXRES SI_RCTL resource-control generated signal
SIGHUP
SIGTERM

The uncatchable signals SIGSTOP and SIGKILL have undefined siginfo codes.

Signals sent with a siginfo code of SI_RCTL contain code-dependent information for kernel-generated signals:

Code Field Value
SI_RCTL hr_time si_entity process-model entity of control

In addition, the following signal-dependent information is available for kernel-generated signals:

Signal Field Value
SIGILL caddr_t si_addr address of faulting instruction
SIGFPE
SIGSEGV caddr_t si_addr address of faulting memory reference
SIGBUS
SIGCHLD pid_t si_pid child process ID
int si_status exit value or signal
SIGPOLL long si_band
band event for POLL_IN, POLL_OUT, or POLL_MSG
SEE ALSO

_lwp_kill(2), kill(2), setrctl(2), sigaction(2), sigsend(2), waitid(2), abort(3C), aio_read(3C), mq_notify(3C), raise(3C), signal.h(3HEAD), sigqueue(3C), timer_create(3C), timer_settime(3C)

NOTES

For SIGCHLD signals, if si_code is equal to CLD_EXITED, then si_status is equal to the exit value of the process; otherwise, it is equal to the signal that caused the process to change state. For some implementations, the exact value of si_addr might not be available; in that case, si_addr is guaranteed to be on the same page as the faulting instruction or memory reference.