1# 2# Copyright 2006 Sun Microsystems, Inc. All rights reserved. 3# Use is subject to license terms. 4# 5# CDDL HEADER START 6# 7# The contents of this file are subject to the terms of the 8# Common Development and Distribution License (the "License"). 9# You may not use this file except in compliance with the License. 10# 11# You can obtain a copy of the license at usr/src/OPENSOLARIS.LICENSE 12# or http://www.opensolaris.org/os/licensing. 13# See the License for the specific language governing permissions 14# and limitations under the License. 15# 16# When distributing Covered Code, include this CDDL HEADER in each 17# file and include the License file at usr/src/OPENSOLARIS.LICENSE. 18# If applicable, add the following below this CDDL HEADER, with the 19# fields enclosed by brackets "[]" replaced with your own identifying 20# information: Portions Copyright [yyyy] [name of copyright owner] 21# 22# CDDL HEADER END 23# 24#ident "%Z%%M% %I% %E% SMI" 25# 26# DO NOT EDIT -- this file is generated by the Event Registry. 27# 28# 29# code: SUN4V-8000-1S 30# keys: fault.cpu.ultraSPARC-T1.ireg 31# 32msgid "SUN4V-8000-1S.type" 33msgstr "Fault" 34msgid "SUN4V-8000-1S.severity" 35msgstr "Minor" 36msgid "SUN4V-8000-1S.description" 37msgstr "The number of errors associated with this CPU has exceeded \n acceptable levels. Refer to %s for more information." 38msgid "SUN4V-8000-1S.response" 39msgstr "The fault manager will attempt to remove the affected CPU from service." 40msgid "SUN4V-8000-1S.impact" 41msgstr "System performance may be affected." 42msgid "SUN4V-8000-1S.action" 43msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>." 44# 45# code: SUN4V-8000-2A 46# keys: fault.cpu.ultraSPARC-T1.freg 47# 48msgid "SUN4V-8000-2A.type" 49msgstr "Fault" 50msgid "SUN4V-8000-2A.severity" 51msgstr "Major" 52msgid "SUN4V-8000-2A.description" 53msgstr "The number of errors associated with this CPU has exceeded \n acceptable levels. Refer to %s for more information." 54msgid "SUN4V-8000-2A.response" 55msgstr "None" 56msgid "SUN4V-8000-2A.impact" 57msgstr "System performance may be affected." 58msgid "SUN4V-8000-2A.action" 59msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>." 60# 61# code: SUN4V-8000-3P 62# keys: fault.cpu.ultraSPARC-T1.itlb 63# 64msgid "SUN4V-8000-3P.type" 65msgstr "Fault" 66msgid "SUN4V-8000-3P.severity" 67msgstr "Minor" 68msgid "SUN4V-8000-3P.description" 69msgstr "The number of errors associated with this CPU has exceeded \n acceptable levels. Refer to %s for more information." 70msgid "SUN4V-8000-3P.response" 71msgstr "The fault manager will attempt to remove the affected CPU from service." 72msgid "SUN4V-8000-3P.impact" 73msgstr "System performance may be affected.\n" 74msgid "SUN4V-8000-3P.action" 75msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>." 76# 77# code: SUN4V-8000-4D 78# keys: fault.cpu.ultraSPARC-T1.dtlb 79# 80msgid "SUN4V-8000-4D.type" 81msgstr "Fault" 82msgid "SUN4V-8000-4D.severity" 83msgstr "Minor" 84msgid "SUN4V-8000-4D.description" 85msgstr "The number of errors associated with this CPU has exceeded \n acceptable levels. Refer to %s for more information." 86msgid "SUN4V-8000-4D.response" 87msgstr "The fault manager will attempt to remove the affected CPU from service." 88msgid "SUN4V-8000-4D.impact" 89msgstr "System performance may be affected.\n" 90msgid "SUN4V-8000-4D.action" 91msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>." 92# 93# code: SUN4V-8000-5H 94# keys: fault.cpu.ultraSPARC-T1.icache 95# 96msgid "SUN4V-8000-5H.type" 97msgstr "Fault" 98msgid "SUN4V-8000-5H.severity" 99msgstr "Minor" 100msgid "SUN4V-8000-5H.description" 101msgstr "The number of errors associated with this CPU has exceeded \n acceptable levels. Refer to %s for more information." 102msgid "SUN4V-8000-5H.response" 103msgstr "The fault manager will attempt to remove the affected CPU from service." 104msgid "SUN4V-8000-5H.impact" 105msgstr "System performance may be affected.\n" 106msgid "SUN4V-8000-5H.action" 107msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>." 108# 109# code: SUN4V-8000-63 110# keys: fault.cpu.ultraSPARC-T1.dcache 111# 112msgid "SUN4V-8000-63.type" 113msgstr "Fault" 114msgid "SUN4V-8000-63.severity" 115msgstr "Minor" 116msgid "SUN4V-8000-63.description" 117msgstr "The number of errors associated with this CPU has exceeded \n acceptable levels. Refer to %s for more information." 118msgid "SUN4V-8000-63.response" 119msgstr "The fault manager will attempt to remove the affected CPU from service." 120msgid "SUN4V-8000-63.impact" 121msgstr "System performance may be affected.\n" 122msgid "SUN4V-8000-63.action" 123msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>." 124# 125# code: SUN4V-8000-7Y 126# keys: fault.cpu.ultraSPARC-T1.mau 127# 128msgid "SUN4V-8000-7Y.type" 129msgstr "Fault" 130msgid "SUN4V-8000-7Y.severity" 131msgstr "Major" 132msgid "SUN4V-8000-7Y.description" 133msgstr "The number of errors associated with this CPU has exceeded \n acceptable levels. Refer to %s for more information." 134msgid "SUN4V-8000-7Y.response" 135msgstr "None" 136msgid "SUN4V-8000-7Y.impact" 137msgstr "System performance may be affected.\n" 138msgid "SUN4V-8000-7Y.action" 139msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>." 140# 141# code: SUN4V-8000-8Q 142# keys: fault.cpu.ultraSPARC-T1.l2cachedata 143# 144msgid "SUN4V-8000-8Q.type" 145msgstr "Fault" 146msgid "SUN4V-8000-8Q.severity" 147msgstr "Critical" 148msgid "SUN4V-8000-8Q.description" 149msgstr "The number of errors associated with this CPU has exceeded \n acceptable levels. Refer to %s for more information." 150msgid "SUN4V-8000-8Q.response" 151msgstr "None" 152msgid "SUN4V-8000-8Q.impact" 153msgstr "System performance may be affected.\n" 154msgid "SUN4V-8000-8Q.action" 155msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>." 156# 157# code: SUN4V-8000-9C 158# keys: fault.cpu.ultraSPARC-T1.l2cachetag 159# 160msgid "SUN4V-8000-9C.type" 161msgstr "Fault" 162msgid "SUN4V-8000-9C.severity" 163msgstr "Critical" 164msgid "SUN4V-8000-9C.description" 165msgstr "The number of errors associated with this CPU has exceeded \n acceptable levels. Refer to %s for more information." 166msgid "SUN4V-8000-9C.response" 167msgstr "None" 168msgid "SUN4V-8000-9C.impact" 169msgstr "System performance may be affected.\n" 170msgid "SUN4V-8000-9C.action" 171msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>." 172# 173# code: SUN4V-8000-AR 174# keys: fault.cpu.ultraSPARC-T1.l2cachectl 175# 176msgid "SUN4V-8000-AR.type" 177msgstr "Fault" 178msgid "SUN4V-8000-AR.severity" 179msgstr "Critical" 180msgid "SUN4V-8000-AR.description" 181msgstr "The number of errors associated with this CPU has exceeded \n acceptable levels. Refer to %s for more information." 182msgid "SUN4V-8000-AR.response" 183msgstr "None" 184msgid "SUN4V-8000-AR.impact" 185msgstr "System performance may be affected.\n" 186msgid "SUN4V-8000-AR.action" 187msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>." 188# 189# code: SUN4V-8000-C4 190# keys: fault.memory.page 191# 192msgid "SUN4V-8000-C4.type" 193msgstr "Fault" 194msgid "SUN4V-8000-C4.severity" 195msgstr "Minor" 196msgid "SUN4V-8000-C4.description" 197msgstr "The number of errors associated with this memory module continues to exceed acceptable levels. Refer to %s for more information." 198msgid "SUN4V-8000-C4.response" 199msgstr "An attempt will be made to remove this memory page from service." 200msgid "SUN4V-8000-C4.impact" 201msgstr "The performance of the system may be minimally impacted as a result of removing the memory page from operation." 202msgid "SUN4V-8000-C4.action" 203msgstr "No repair action is recommended at this time." 204# 205# code: SUN4V-8000-DX 206# keys: fault.memory.dimm 207# 208msgid "SUN4V-8000-DX.type" 209msgstr "Fault" 210msgid "SUN4V-8000-DX.severity" 211msgstr "Major" 212msgid "SUN4V-8000-DX.description" 213msgstr "The number of errors associated with this memory module has exceeded acceptable levels. Refer to %s for more information." 214msgid "SUN4V-8000-DX.response" 215msgstr "Pages of memory associated with this memory module are being removed from service as errors are reported." 216msgid "SUN4V-8000-DX.impact" 217msgstr "Total system memory capacity will be reduced as pages are retired." 218msgid "SUN4V-8000-DX.action" 219msgstr "Schedule a repair procedure to replace the affected memory module. Use fmdump -v -u <EVENT_ID> to identify the module." 220# 221# code: SUN4V-8000-E2 222# keys: fault.memory.bank 223# 224msgid "SUN4V-8000-E2.type" 225msgstr "Fault" 226msgid "SUN4V-8000-E2.severity" 227msgstr "Critical" 228msgid "SUN4V-8000-E2.description" 229msgstr "The number of errors associated with this memory module has exceeded acceptable levels. Refer to %s for more information." 230msgid "SUN4V-8000-E2.response" 231msgstr "Pages of memory associated with this memory module are being removed from service as errors are reported." 232msgid "SUN4V-8000-E2.impact" 233msgstr "Total system memory capacity will be reduced as pages are retired." 234msgid "SUN4V-8000-E2.action" 235msgstr "Schedule a repair procedure to replace the affected memory module. Use fmdump -v -u <EVENT_ID> to identify the module." 236# 237# code: SUN4V-8000-FJ 238# keys: fault.memory.link-c 239# 240msgid "SUN4V-8000-FJ.type" 241msgstr "Fault" 242msgid "SUN4V-8000-FJ.severity" 243msgstr "Major" 244msgid "SUN4V-8000-FJ.description" 245msgstr "A problem was detected in the interconnect between a memory DIMM module and\nits memory controller. \n Refer to %s for more information." 246msgid "SUN4V-8000-FJ.response" 247msgstr "No automated response.\n" 248msgid "SUN4V-8000-FJ.impact" 249msgstr "System performance may be impacted.\n" 250msgid "SUN4V-8000-FJ.action" 251msgstr "At convenient time, try reseating the memory module(s). If problem persists,\ncontact Sun to schedule part replacement.\n" 252# 253# code: SUN4V-8000-GE 254# keys: fault.cpu.ultraSPARC-T2.ireg 255# 256msgid "SUN4V-8000-GE.type" 257msgstr "Fault" 258msgid "SUN4V-8000-GE.severity" 259msgstr "Minor" 260msgid "SUN4V-8000-GE.description" 261msgstr "The number of integer register errors associated with this thread has exceeded acceptable levels.\n Refer to %s for more information." 262msgid "SUN4V-8000-GE.response" 263msgstr "The fault manager will attempt to remove the affected thread\nfrom service.\n" 264msgid "SUN4V-8000-GE.impact" 265msgstr "System performance may be affected. \n" 266msgid "SUN4V-8000-GE.action" 267msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n" 268# 269# code: SUN4V-8000-HP 270# keys: fault.cpu.ultraSPARC-T2.freg 271# 272msgid "SUN4V-8000-HP.type" 273msgstr "Fault" 274msgid "SUN4V-8000-HP.severity" 275msgstr "Minor" 276msgid "SUN4V-8000-HP.description" 277msgstr "The number of floating register errors associated with this thread has exceeded acceptable levels.\n Refer to %s for more information." 278msgid "SUN4V-8000-HP.response" 279msgstr "The fault manager will attempt to remove the affected thread\nfrom service.\n" 280msgid "SUN4V-8000-HP.impact" 281msgstr "System performance may be affected. \n" 282msgid "SUN4V-8000-HP.action" 283msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n" 284# 285# code: SUN4V-8000-JA 286# keys: fault.cpu.ultraSPARC-T2.misc_reg 287# 288msgid "SUN4V-8000-JA.type" 289msgstr "Fault" 290msgid "SUN4V-8000-JA.severity" 291msgstr "Minor" 292msgid "SUN4V-8000-JA.description" 293msgstr "The number of ancillary register errors associated with this thread has exceeded acceptable levels.\n Refer to %s for more information." 294msgid "SUN4V-8000-JA.response" 295msgstr "The fault manager will attempt to remove the affected thread\nfrom service.\n" 296msgid "SUN4V-8000-JA.impact" 297msgstr "System performance may be affected. \n" 298msgid "SUN4V-8000-JA.action" 299msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n" 300# 301# code: SUN4V-8000-KS 302# keys: fault.cpu.ultraSPARC-T2.itlb 303# 304msgid "SUN4V-8000-KS.type" 305msgstr "Fault" 306msgid "SUN4V-8000-KS.severity" 307msgstr "Major" 308msgid "SUN4V-8000-KS.description" 309msgstr "The number of ITLB errors associated with this thread has exceeded acceptable levels.\n Refer to %s for more information." 310msgid "SUN4V-8000-KS.response" 311msgstr "The fault manager will attempt to remove all threads associated with\nthis resource from service.\n" 312msgid "SUN4V-8000-KS.impact" 313msgstr "System performance is likely to be affected. \n" 314msgid "SUN4V-8000-KS.action" 315msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n" 316# 317# code: SUN4V-8000-L5 318# keys: fault.cpu.ultraSPARC-T2.dtlb 319# 320msgid "SUN4V-8000-L5.type" 321msgstr "Fault" 322msgid "SUN4V-8000-L5.severity" 323msgstr "Major" 324msgid "SUN4V-8000-L5.description" 325msgstr "The number of DTLB errors associated with this thread has exceeded acceptable levels.\n Refer to %s for more information." 326msgid "SUN4V-8000-L5.response" 327msgstr "The fault manager will attempt to remove all threads associated with\nthis resource from service.\n" 328msgid "SUN4V-8000-L5.impact" 329msgstr "System performance is likely to be affected. \n" 330msgid "SUN4V-8000-L5.action" 331msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n" 332# 333# code: SUN4V-8000-MY 334# keys: fault.cpu.ultraSPARC-T2.icache 335# 336msgid "SUN4V-8000-MY.type" 337msgstr "Fault" 338msgid "SUN4V-8000-MY.severity" 339msgstr "Major" 340msgid "SUN4V-8000-MY.description" 341msgstr "The number of I-cache errors associated with this thread has exceeded acceptable levels.\n Refer to %s for more information." 342msgid "SUN4V-8000-MY.response" 343msgstr "The fault manager will attempt to remove all threads associated with\nthis resource from service.\n" 344msgid "SUN4V-8000-MY.impact" 345msgstr "System performance is likely to be affected. \n" 346msgid "SUN4V-8000-MY.action" 347msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n" 348# 349# code: SUN4V-8000-N3 350# keys: fault.cpu.ultraSPARC-T2.dcache 351# 352msgid "SUN4V-8000-N3.type" 353msgstr "Fault" 354msgid "SUN4V-8000-N3.severity" 355msgstr "Major" 356msgid "SUN4V-8000-N3.description" 357msgstr "The number of D-cache errors associated with this thread has exceeded acceptable levels.\n Refer to %s for more information." 358msgid "SUN4V-8000-N3.response" 359msgstr "The fault manager will attempt to remove all threads associated with\nthis resource from service.\n" 360msgid "SUN4V-8000-N3.impact" 361msgstr "System performance is likely to be affected. \n" 362msgid "SUN4V-8000-N3.action" 363msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n" 364# 365# code: SUN4V-8000-PH 366# keys: fault.cpu.ultraSPARC-T2.mau 367# 368msgid "SUN4V-8000-PH.type" 369msgstr "Fault" 370msgid "SUN4V-8000-PH.severity" 371msgstr "Major" 372msgid "SUN4V-8000-PH.description" 373msgstr "The number of modular arithmetic unit errors associated with this thread has exceeded acceptable levels.\n Refer to %s for more information." 374msgid "SUN4V-8000-PH.response" 375msgstr "The fault manager will attempt to remove all threads associated with\nthis resource from service.\n" 376msgid "SUN4V-8000-PH.impact" 377msgstr "System performance is likely to be affected. \n" 378msgid "SUN4V-8000-PH.action" 379msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n" 380# 381# code: SUN4V-8000-QD 382# keys: fault.cpu.ultraSPARC-T2.l2data-c 383# 384msgid "SUN4V-8000-QD.type" 385msgstr "Fault" 386msgid "SUN4V-8000-QD.severity" 387msgstr "Critical" 388msgid "SUN4V-8000-QD.description" 389msgstr "The number of level 2 cache correctable data errors has exceeded acceptable levels.\n Refer to %s for more information." 390msgid "SUN4V-8000-QD.response" 391msgstr "No automated response.\n" 392msgid "SUN4V-8000-QD.impact" 393msgstr "System performance is likely to be affected. \n" 394msgid "SUN4V-8000-QD.action" 395msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n" 396# 397# code: SUN4V-8000-R4 398# keys: fault.cpu.ultraSPARC-T2.l2cachetag 399# 400msgid "SUN4V-8000-R4.type" 401msgstr "Fault" 402msgid "SUN4V-8000-R4.severity" 403msgstr "Critical" 404msgid "SUN4V-8000-R4.description" 405msgstr "The number of level 2 cache tag errors has exceeded acceptable levels.\n Refer to %s for more information." 406msgid "SUN4V-8000-R4.response" 407msgstr "No automated response.\n" 408msgid "SUN4V-8000-R4.impact" 409msgstr "System performance is likely to be affected. \n" 410msgid "SUN4V-8000-R4.action" 411msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n" 412# 413# code: SUN4V-8000-SR 414# keys: fault.cpu.ultraSPARC-T2.l2cachectl 415# 416msgid "SUN4V-8000-SR.type" 417msgstr "Fault" 418msgid "SUN4V-8000-SR.severity" 419msgstr "Critical" 420msgid "SUN4V-8000-SR.description" 421msgstr "The number of level 2 cache control errors has exceeded acceptable levels.\n Refer to %s for more information." 422msgid "SUN4V-8000-SR.response" 423msgstr "No automated response.\n" 424msgid "SUN4V-8000-SR.impact" 425msgstr "System performance is likely to be affected. System may be unstable.\n" 426msgid "SUN4V-8000-SR.action" 427msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n" 428# 429# code: SUN4V-8000-TC 430# keys: fault.memory.link-u 431# 432msgid "SUN4V-8000-TC.type" 433msgstr "Fault" 434msgid "SUN4V-8000-TC.severity" 435msgstr "Critical" 436msgid "SUN4V-8000-TC.description" 437msgstr "A problem was detected in the interconnect between a memory DIMM module and\nits memory controller. \n Refer to %s for more information." 438msgid "SUN4V-8000-TC.response" 439msgstr "No automated response.\n" 440msgid "SUN4V-8000-TC.impact" 441msgstr "System performance may be impacted.\n" 442msgid "SUN4V-8000-TC.action" 443msgstr "At convenient time, try reseating the memory module. If problem persists,\ncontact Sun to schedule part replacement.\n" 444# 445# code: SUN4V-8000-UQ 446# keys: fault.cpu.ultraSPARC-T2.l2data-u 447# 448msgid "SUN4V-8000-UQ.type" 449msgstr "Fault" 450msgid "SUN4V-8000-UQ.severity" 451msgstr "Critical" 452msgid "SUN4V-8000-UQ.description" 453msgstr "The number of level 2 cache uncorrectable data errors has exceeded acceptable levels.\n Refer to %s for more information." 454msgid "SUN4V-8000-UQ.response" 455msgstr "No automated response.\n" 456msgid "SUN4V-8000-UQ.impact" 457msgstr "System performance is likely to be affected. \n" 458msgid "SUN4V-8000-UQ.action" 459msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n" 460# 461# code: SUN4V-8000-VE 462# keys: fault.cpu.ultraSPARC-T1.l2data-c 463# 464msgid "SUN4V-8000-VE.type" 465msgstr "Fault" 466msgid "SUN4V-8000-VE.severity" 467msgstr "Critical" 468msgid "SUN4V-8000-VE.description" 469msgstr "The number of level 2 cache correctable data errors has exceeded acceptable levels.\n Refer to %s for more information." 470msgid "SUN4V-8000-VE.response" 471msgstr "No automated response.\n" 472msgid "SUN4V-8000-VE.impact" 473msgstr "System performance is likely to be affected. \n" 474msgid "SUN4V-8000-VE.action" 475msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n" 476# 477# code: SUN4V-8000-WJ 478# keys: fault.cpu.ultraSPARC-T1.l2data-u 479# 480msgid "SUN4V-8000-WJ.type" 481msgstr "Fault" 482msgid "SUN4V-8000-WJ.severity" 483msgstr "Critical" 484msgid "SUN4V-8000-WJ.description" 485msgstr "The number of level 2 cache uncorrectable data errors has exceeded acceptable levels.\n Refer to %s for more information." 486msgid "SUN4V-8000-WJ.response" 487msgstr "No automated response.\n" 488msgid "SUN4V-8000-WJ.impact" 489msgstr "System performance is likely to be affected. \n" 490msgid "SUN4V-8000-WJ.action" 491msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n" 492# 493# code: SUN4V-8000-X2 494# keys: fault.memory.datapath 495# 496msgid "SUN4V-8000-X2.type" 497msgstr "Fault" 498msgid "SUN4V-8000-X2.severity" 499msgstr "Major" 500msgid "SUN4V-8000-X2.description" 501msgstr "Errors have been detected on multiple memory modules, suggesting that a problem exists somewhere else in the system.\n Refer to %s for more information." 502msgid "SUN4V-8000-X2.response" 503msgstr "Error reports from the affected components will be logged for examination by Sun.\n" 504msgid "SUN4V-8000-X2.impact" 505msgstr "System performance and stability may be affected. \n" 506msgid "SUN4V-8000-X2.action" 507msgstr "Contact your service provider for further diagnosis.\n" 508# 509# code: SUN4V-8000-YX 510# keys: fault.io.n2.ncu 511# 512msgid "SUN4V-8000-YX.type" 513msgstr "Fault" 514msgid "SUN4V-8000-YX.severity" 515msgstr "Critical" 516msgid "SUN4V-8000-YX.description" 517msgstr "A problem was detected in the NCU subsystem of the N2's SOC\n Refer to %s for more information." 518msgid "SUN4V-8000-YX.response" 519msgstr "One or more device instances may be disabled\n" 520msgid "SUN4V-8000-YX.impact" 521msgstr "Loss of services provided by the device\ninstances associated with this fault\n" 522msgid "SUN4V-8000-YX.action" 523msgstr "Schedule a repair procedure to replace the affected\ndevice if necessary, or contact Sun for support.\n" 524# 525# code: SUN4V-8001-02 526# keys: fault.io.n2.dmu 527# 528msgid "SUN4V-8001-02.type" 529msgstr "Fault" 530msgid "SUN4V-8001-02.severity" 531msgstr "Critical" 532msgid "SUN4V-8001-02.description" 533msgstr "A problem was detected in the DMU subsystem of the N2's SOC\n Refer to %s for more information." 534msgid "SUN4V-8001-02.response" 535msgstr "One or more device instances may be disabled\n" 536msgid "SUN4V-8001-02.impact" 537msgstr "Loss of services provided by the device\ninstances associated with this fault\n" 538msgid "SUN4V-8001-02.action" 539msgstr "Schedule a repair procedure to replace the affected\ndevice if necessary, or contact Sun for support.\n" 540# 541# code: SUN4V-8001-1X 542# keys: fault.io.n2.niu 543# 544msgid "SUN4V-8001-1X.type" 545msgstr "Fault" 546msgid "SUN4V-8001-1X.severity" 547msgstr "Critical" 548msgid "SUN4V-8001-1X.description" 549msgstr "A problem was detected in the NIU subsystem of the N2's SOC\n Refer to %s for more information." 550msgid "SUN4V-8001-1X.response" 551msgstr "One or more device instances may be disabled\n" 552msgid "SUN4V-8001-1X.impact" 553msgstr "Loss of services provided by the device\ninstances associated with this fault\n" 554msgid "SUN4V-8001-1X.action" 555msgstr "Schedule a repair procedure to replace the affected\ndevice if necessary, or contact Sun for support.\n" 556# 557# code: SUN4V-8001-2E 558# keys: fault.io.n2.siu 559# 560msgid "SUN4V-8001-2E.type" 561msgstr "Fault" 562msgid "SUN4V-8001-2E.severity" 563msgstr "Critical" 564msgid "SUN4V-8001-2E.description" 565msgstr "A problem was detected in the SIU subsystem of the N2's SOC\n Refer to %s for more information." 566msgid "SUN4V-8001-2E.response" 567msgstr "One or more device instances may be disabled\n" 568msgid "SUN4V-8001-2E.impact" 569msgstr "Loss of services provided by the device\ninstances associated with this fault\n" 570msgid "SUN4V-8001-2E.action" 571msgstr "Schedule a repair procedure to replace the affected\ndevice if necessary, or contact Sun for support.\n" 572# 573# code: SUN4V-8001-3J 574# keys: fault.io.n2.soc 575# 576msgid "SUN4V-8001-3J.type" 577msgstr "Fault" 578msgid "SUN4V-8001-3J.severity" 579msgstr "Critical" 580msgid "SUN4V-8001-3J.description" 581msgstr "A problem was detected in N2's SOC\n Refer to %s for more information." 582msgid "SUN4V-8001-3J.response" 583msgstr "One or more device instances may be disabled\n" 584msgid "SUN4V-8001-3J.impact" 585msgstr "Loss of services provided by the device\ninstances associated with this fault\n" 586msgid "SUN4V-8001-3J.action" 587msgstr "Schedule a repair procedure to replace the affected\ndevice if necessary, or contact Sun for support.\n" 588# 589# code: SUN4V-8001-4C 590# keys: fault.io.n2.crossbar 591# 592msgid "SUN4V-8001-4C.type" 593msgstr "Fault" 594msgid "SUN4V-8001-4C.severity" 595msgstr "Critical" 596msgid "SUN4V-8001-4C.description" 597msgstr "A problem was detected in the crossbar of the N2's SOC\n Refer to %s for more information." 598msgid "SUN4V-8001-4C.response" 599msgstr "One or more device instances may be disabled\n" 600msgid "SUN4V-8001-4C.impact" 601msgstr "Loss of services provided by the device\ninstances associated with this fault\n" 602msgid "SUN4V-8001-4C.action" 603msgstr "Schedule a repair procedure to replace the affected\ndevice if necessary, or contact Sun for support.\n" 604