xref: /titanic_44/usr/src/cmd/fm/dicts/SCA500.po (revision 15deec582ef80846f1c88f9f61d26d8dbb992894)
1 #
2 # Copyright 2006 Sun Microsystems, Inc.  All rights reserved.
3 # Use is subject to license terms.
4 #
5 # CDDL HEADER START
6 #
7 # The contents of this file are subject to the terms of the
8 # Common Development and Distribution License (the "License").
9 # You may not use this file except in compliance with the License.
10 #
11 # You can obtain a copy of the license at usr/src/OPENSOLARIS.LICENSE
12 # or http://www.opensolaris.org/os/licensing.
13 # See the License for the specific language governing permissions
14 # and limitations under the License.
15 #
16 # When distributing Covered Code, include this CDDL HEADER in each
17 # file and include the License file at usr/src/OPENSOLARIS.LICENSE.
18 # If applicable, add the following below this CDDL HEADER, with the
19 # fields enclosed by brackets "[]" replaced with your own identifying
20 # information: Portions Copyright [yyyy] [name of copyright owner]
21 #
22 # CDDL HEADER END
23 #
24 #ident	"%Z%%M%	%I%	%E% SMI"
25 #
26 # DO NOT EDIT -- this file is generated by the Event Registry.
27 #
28 #
29 # code: SCA500-8000-0D
30 # keys: fault.io.sca500.hw
31 #
32 msgid "SCA500-8000-0D.type"
33 msgstr "Fault"
34 msgid "SCA500-8000-0D.severity"
35 msgstr "Major"
36 msgid "SCA500-8000-0D.description"
37 msgstr "The Solaris Fault Manager has detected a hardware failure on the Sun Crypto Accelerator 500 card.  Refer to %s for more information."
38 msgid "SCA500-8000-0D.response"
39 msgstr "The module has been disabled and un-registered as a hardware provider to the Solaris Cryptographic Framework."
40 msgid "SCA500-8000-0D.impact"
41 msgstr "The card will no longer function as a cryptographic accelerator."
42 msgid "SCA500-8000-0D.action"
43 msgstr "Ensure that the board is securely installed on the system.\n\nUse the cryptoadm(1M) command\n\ncryptoadm list -p\n\n\nto check whether 'dca/x' (where x is a number) is listed under 'kernel hardware\nproviders'. If so, run diagnostics on the hardware provider using SUNVTS\nfollowing the procedures described in the Sun Crypto Accelerator 1000 Board\nUser's Guide.\n\nUse the fmdump(1M) command\n\nfmdump -vu event-id\n\n\nto view the results of diagnosis and the specific Field Replaceable\nUnit (FRU) identified for replacement.\n\nThe event-id can be found in the EVENT-ID field of the message.\nFor example:\n\n\nEVENT-ID: 39b30371-f009-c76c-90ee-b245784d2277\n"