xref: /titanic_44/usr/src/cmd/fm/dicts/FMD.po (revision 54925bf60766fbb4f1f2d7c843721406a7b7a3fb)
1#
2# Copyright 2006 Sun Microsystems, Inc.  All rights reserved.
3# Use is subject to license terms.
4#
5# CDDL HEADER START
6#
7# The contents of this file are subject to the terms of the
8# Common Development and Distribution License (the "License").
9# You may not use this file except in compliance with the License.
10#
11# You can obtain a copy of the license at usr/src/OPENSOLARIS.LICENSE
12# or http://www.opensolaris.org/os/licensing.
13# See the License for the specific language governing permissions
14# and limitations under the License.
15#
16# When distributing Covered Code, include this CDDL HEADER in each
17# file and include the License file at usr/src/OPENSOLARIS.LICENSE.
18# If applicable, add the following below this CDDL HEADER, with the
19# fields enclosed by brackets "[]" replaced with your own identifying
20# information: Portions Copyright [yyyy] [name of copyright owner]
21#
22# CDDL HEADER END
23#
24#ident	"%Z%%M%	%I%	%E% SMI"
25#
26# DO NOT EDIT -- this file is generated by the Event Registry.
27#
28#
29# General-purpose messages
30#
31msgid "syslog-msgs-message-template"
32msgstr "SUNW-MSG-ID: %s, TYPE: %s, VER: 1, SEVERITY: %s\nEVENT-TIME: %s\nPLATFORM: %s, CSN: %s, HOSTNAME: %s\nSOURCE: %s, REV: %s\nEVENT-ID: %s\nDESC: %s\nAUTO-RESPONSE: %s\nIMPACT: %s\nREC-ACTION: %s\n"
33#
34# Fault-related messages
35#
36#
37#
38# code: FMD-8000-0W
39# keys: defect.sunos.fmd.nosub
40#
41msgid "FMD-8000-0W.type"
42msgstr "Defect"
43msgid "FMD-8000-0W.severity"
44msgstr "Minor"
45msgid "FMD-8000-0W.description"
46msgstr "The Solaris Fault Manager received an event from a component to which no automated diagnosis software is currently subscribed.  Refer to %s for more information."
47msgid "FMD-8000-0W.response"
48msgstr "Error reports from the component will be logged for examination by Sun."
49msgid "FMD-8000-0W.impact"
50msgstr "Automated diagnosis and response for these events will not occur."
51msgid "FMD-8000-0W.action"
52msgstr "Run pkgchk -n SUNWfmd to ensure that fault management software is installed properly.  Contact Sun for support."
53#
54# code: FMD-8000-11
55# keys: defect.sunos.fmd.nodiagcode
56#
57msgid "FMD-8000-11.type"
58msgstr "Defect"
59msgid "FMD-8000-11.severity"
60msgstr "Minor"
61msgid "FMD-8000-11.description"
62msgstr "A Solaris Fault Manager component generated a diagnosis for which no message summary exists.  Refer to %s for more information."
63msgid "FMD-8000-11.response"
64msgstr "The diagnosis has been saved in the fault log for examination by Sun."
65msgid "FMD-8000-11.impact"
66msgstr "The fault log will need to be manually examined using fmdump(1M) in order to determine if any human response is required."
67msgid "FMD-8000-11.action"
68msgstr "Use fmdump -v -u <EVENT-ID> to view the diagnosis result.  Run pkgchk -n SUNWfmd to ensure that fault management software is installed properly."
69#
70# code: FMD-8000-2K
71# keys: defect.sunos.fmd.module
72#
73msgid "FMD-8000-2K.type"
74msgstr "Defect"
75msgid "FMD-8000-2K.severity"
76msgstr "Minor"
77msgid "FMD-8000-2K.description"
78msgstr "A Solaris Fault Manager component has experienced an error that required the module to be disabled.  Refer to %s for more information."
79msgid "FMD-8000-2K.response"
80msgstr "The module has been disabled.  Events destined for the module will be saved for manual diagnosis."
81msgid "FMD-8000-2K.impact"
82msgstr "Automated diagnosis and response for subsequent events associated with this module will not occur."
83msgid "FMD-8000-2K.action"
84msgstr "Use fmdump -v -u <EVENT-ID> to locate the module.  Use fmadm reset <module> to reset the module."
85#
86# code: FMD-8000-3F
87# keys: defect.sunos.fmd.config
88#
89msgid "FMD-8000-3F.type"
90msgstr "Defect"
91msgid "FMD-8000-3F.severity"
92msgstr "Minor"
93msgid "FMD-8000-3F.description"
94msgstr "A Solaris Fault Manager component could not load due to an erroroneous configuration file.  Refer to %s for more information."
95msgid "FMD-8000-3F.response"
96msgstr "The module has been disabled.  Events destined for the module will be saved for manual diagnosis."
97msgid "FMD-8000-3F.impact"
98msgstr "Automated diagnosis and response for subsequent events associated with this module will not occur."
99msgid "FMD-8000-3F.action"
100msgstr "Use fmdump -v -u <EVENT-ID> to locate the module.  Use fmadm load <module> to load the module after repairing its configuration."
101