xref: /titanic_44/usr/src/cmd/fm/dicts/DISK.po (revision a4aeef46cda1835da2b19f8f62b4526de6521e6c)
1#
2# Copyright 2008 Sun Microsystems, Inc.  All rights reserved.
3# Use is subject to license terms.
4#
5# CDDL HEADER START
6#
7# The contents of this file are subject to the terms of the
8# Common Development and Distribution License (the "License").
9# You may not use this file except in compliance with the License.
10#
11# You can obtain a copy of the license at usr/src/OPENSOLARIS.LICENSE
12# or http://www.opensolaris.org/os/licensing.
13# See the License for the specific language governing permissions
14# and limitations under the License.
15#
16# When distributing Covered Code, include this CDDL HEADER in each
17# file and include the License file at usr/src/OPENSOLARIS.LICENSE.
18# If applicable, add the following below this CDDL HEADER, with the
19# fields enclosed by brackets "[]" replaced with your own identifying
20# information: Portions Copyright [yyyy] [name of copyright owner]
21#
22# CDDL HEADER END
23#
24#
25# DO NOT EDIT -- this file is generated by the Event Registry.
26#
27#
28# code: DISK-8000-0X
29# keys: fault.io.disk.predictive-failure
30#
31msgid "DISK-8000-0X.type"
32msgstr "Fault"
33msgid "DISK-8000-0X.severity"
34msgstr "Major"
35msgid "DISK-8000-0X.description"
36msgstr "SMART health-monitoring firmware reported that a disk\nfailure is imminent.\n  Refer to %s for more information."
37msgid "DISK-8000-0X.response"
38msgstr "None.\n"
39msgid "DISK-8000-0X.impact"
40msgstr "It is likely that the continued operation of\nthis disk will result in data loss.\n"
41msgid "DISK-8000-0X.action"
42msgstr "Schedule a repair procedure to replace the affected disk.\nUse fmdump -v -u <EVENT_ID> to identify the disk.\n"
43#
44# code: DISK-8000-12
45# keys: fault.io.disk.over-temperature
46#
47msgid "DISK-8000-12.type"
48msgstr "Fault"
49msgid "DISK-8000-12.severity"
50msgstr "Major"
51msgid "DISK-8000-12.description"
52msgstr "A disk's temperature exceeded the limits established by\nits manufacturer.\n  Refer to %s for more information."
53msgid "DISK-8000-12.response"
54msgstr "None.\n"
55msgid "DISK-8000-12.impact"
56msgstr "Performance degradation is likely and continued disk operation\nbeyond the temperature threshold can result in disk\ndamage and potential data loss.\n"
57msgid "DISK-8000-12.action"
58msgstr "Ensure that the system is properly cooled, that all fans are\nfunctional, and that there are no obstructions of airflow to the affected\ndisk.\n"
59#
60# code: DISK-8000-2J
61# keys: fault.io.disk.self-test-failure
62#
63msgid "DISK-8000-2J.type"
64msgstr "Fault"
65msgid "DISK-8000-2J.severity"
66msgstr "Critical"
67msgid "DISK-8000-2J.description"
68msgstr "One or more disk self tests failed.\n  Refer to %s for more information."
69msgid "DISK-8000-2J.response"
70msgstr "None.\n"
71msgid "DISK-8000-2J.impact"
72msgstr "The disk has failed.\n"
73msgid "DISK-8000-2J.action"
74msgstr "Schedule a repair procedure to replace the affected disk.\nUse fmdump -v -u <EVENT_ID> to identify the disk.\n"
75#
76# code: DISK-8000-3E
77# keys: fault.io.scsi.cmd.disk.dev.rqs.derr
78#
79msgid "DISK-8000-3E.type"
80msgstr "Fault"
81msgid "DISK-8000-3E.severity"
82msgstr "Critical"
83msgid "DISK-8000-3E.description"
84msgstr "A non-recoverable hardware failure was detected by the device while performing a command.\n  Refer to %s for more information."
85msgid "DISK-8000-3E.response"
86msgstr "The device may be offlined or degraded.\n"
87msgid "DISK-8000-3E.impact"
88msgstr "The device has failed. The service may have been lost or degraded.\n"
89msgid "DISK-8000-3E.action"
90msgstr "Ensure that the latest drivers and patches are installed. Schedule a repair procedure to replace the affected\ndevice. Use 'fmadm faulty' to find the affected disk.\n"
91#
92# code: DISK-8000-4Q
93# keys: fault.io.scsi.cmd.disk.dev.rqs.merr
94#
95msgid "DISK-8000-4Q.type"
96msgstr "Fault"
97msgid "DISK-8000-4Q.severity"
98msgstr "Critical"
99msgid "DISK-8000-4Q.description"
100msgstr "The command was terminated with a non-recovered error condition that may have been caused by a flaw in the media or an error in the recorded data. \n  Refer to %s for more information."
101msgid "DISK-8000-4Q.response"
102msgstr "The device may be offlined or degraded.\n"
103msgid "DISK-8000-4Q.impact"
104msgstr "It is likely that continued operation will result in data corruption, which may eventually cause the loss of service or the service degradation.\n"
105msgid "DISK-8000-4Q.action"
106msgstr "Schedule a repair procedure to replace the affected device. Use 'fmadm faulty' to find the affected disk.\n"
107