1<?xml version="1.0"?> 2<!DOCTYPE topology SYSTEM "/usr/share/lib/xml/dtd/topology.dtd.1"> 3<!-- 4 Copyright 2009 Sun Microsystems, Inc. All rights reserved. 5 Use is subject to license terms. 6 7 CDDL HEADER START 8 9 The contents of this file are subject to the terms of the 10 Common Development and Distribution License (the "License"). 11 You may not use this file except in compliance with the License. 12 13 You can obtain a copy of the license at usr/src/OPENSOLARIS.LICENSE 14 or http://www.opensolaris.org/os/licensing. 15 See the License for the specific language governing permissions 16 and limitations under the License. 17 18 When distributing Covered Code, include this CDDL HEADER in each 19 file and include the License file at usr/src/OPENSOLARIS.LICENSE. 20 If applicable, add the following below this CDDL HEADER, with the 21 fields enclosed by brackets "[]" replaced with your own identifying 22 information: Portions Copyright [yyyy] [name of copyright owner] 23 24 CDDL HEADER END 25 26--> 27 28<topology name='i86pc' scheme='hc'> 29 30 <range name='motherboard' min='0' max='0'> 31 <node instance='0'> 32 <set type='product' setlist='Sun-Fire-X4100-Server|Sun-Fire-X4200-Server|Sun-Fire-X4100-M2|Sun-Fire-X4200-M2|Sun-Fire-X4140|Sun-Fire-X4240|Sun-Fire-X4440|Sun-Fire-X4500|Sun-Fire-X4540|Sun-Fire-X4600-M2'> 33 <fac-enum provider='fac_prov_ipmi' /> 34 <propgroup name='protocol' version='1' 35 name-stability='Private' data-stability='Private' > 36 <propval name='label' type='string' value='MB' /> 37 </propgroup> 38 <propgroup name='ipmi' version='1' 39 name-stability='Private' data-stability='Private' > 40 <propval name='entity_ref' type='string' value='mb.fru' /> 41 </propgroup> 42 43 </set> 44 <set type='product' setlist='SUN-FIRE-X4150|SUN-FIRE-X4250'> 45 <fac-enum provider='fac_prov_ipmi' /> 46 <propgroup name='protocol' version='1' 47 name-stability='Private' data-stability='Private' > 48 <propval name='label' type='string' value='MB' /> 49 </propgroup> 50 <propgroup name='ipmi' version='1' 51 name-stability='Private' data-stability='Private' > 52 <propval name='entity_ref' type='string' value='MB' /> 53 </propgroup> 54 55 </set> 56 <set type='product' setlist='default'> 57 <propgroup name='protocol' version='1' 58 name-stability='Private' data-stability='Private' > 59 <propval name='label' type='string' value='MB' /> 60 </propgroup> 61 </set> 62 </node> 63 64 <dependents grouping='children'> 65 <range name='chip' min='0' max='100'> 66 <enum-method name='chip' version='1' /> 67 <propmap name='chip' /> 68 </range> 69 <range name='hostbridge' min='0' max='254'> 70 <enum-method name='hostbridge' version='1' /> 71 </range> 72 </dependents> 73 74 </range> 75 76 <range name='chassis' min='0' max='0'> 77 <node instance='0'> 78 <set type='product' setlist='Sun-Fire-X4140|Sun-Fire-X4240|Sun-Fire-X4440'> 79 <fac-enum provider='fac_prov_ipmi' /> 80 <propgroup name='ipmi' version='1' 81 name-stability='Private' data-stability='Private' > 82 <propval name='entity_ref' type='string' value='sys.intsw' /> 83 </propgroup> 84 </set> 85 <set type='product' setlist='SUN-FIRE-X4150|SUN-FIRE-X4250'> 86 <fac-enum provider='fac_prov_ipmi' /> 87 <propgroup name='ipmi' version='1' 88 name-stability='Private' data-stability='Private' > 89 <propval name='entity_ref' type='string' value='/SYS/VPS' /> 90 </propgroup> 91 </set> 92 <set type='product' setlist='Sun-Fire-X4100-Server|Sun-Fire-X4200-Server|Sun-Fire-X4100-M2|Sun-Fire-X4200-M2'> 93 <fac-enum provider='fac_prov_ipmi' /> 94 <propgroup name='ipmi' version='1' 95 name-stability='Private' data-stability='Private' > 96 <propval name='entity_ref' type='string' value='sys.intsw' /> 97 </propgroup> 98 <!-- 99 chassis locate and service LED's for Galaxy 1/2 100 --> 101 <facility name='fp.locate.led' type='indicator' provider='fac_prov_ipmi' > 102 <propgroup name='facility' version='1' name-stability='Private' data-stability='Private' > 103 <propval name='entity_ref' type='string' value='fp.locate.led' /> 104 <propval name='type' type='uint32' value='1' /> 105 <propmethod name='ipmi_indicator_mode' version='0' 106 propname='mode' proptype='uint32' mutable='1' > 107 </propmethod> 108 </propgroup> 109 </facility> 110 <facility name='bp.locate.led' type='indicator' provider='fac_prov_ipmi' > 111 <propgroup name='facility' version='1' name-stability='Private' data-stability='Private' > 112 <propval name='entity_ref' type='string' value='bp.locate.led' /> 113 <propval name='type' type='uint32' value='1' /> 114 <propmethod name='ipmi_indicator_mode' version='0' 115 propname='mode' proptype='uint32' mutable='1' > 116 </propmethod> 117 </propgroup> 118 </facility> 119 <facility name='fp.alert.led' type='indicator' provider='fac_prov_ipmi' > 120 <propgroup name='facility' version='1' name-stability='Private' data-stability='Private' > 121 <propval name='entity_ref' type='string' value='fp.alert.led' /> 122 <propval name='type' type='uint32' value='0' /> 123 <propmethod name='ipmi_indicator_mode' version='0' 124 propname='mode' proptype='uint32' mutable='1' > 125 </propmethod> 126 </propgroup> 127 </facility> 128 <facility name='bp.alert.led' type='indicator' provider='fac_prov_ipmi' > 129 <propgroup name='facility' version='1' name-stability='Private' data-stability='Private' > 130 <propval name='entity_ref' type='string' value='bp.alert.led' /> 131 <propval name='type' type='uint32' value='0' /> 132 <propmethod name='ipmi_indicator_mode' version='0' 133 propname='mode' proptype='uint32' mutable='1' > 134 </propmethod> 135 </propgroup> 136 </facility> 137 </set> 138 <set type='product' setlist='Sun-Fire-X4500|Sun-Fire-X4540'> 139 <fac-enum provider='fac_prov_ipmi' /> 140 <propgroup name='ipmi' version='1' 141 name-stability='Private' data-stability='Private' > 142 <propval name='entity_ref' type='string' value='sys.intsw' /> 143 </propgroup> 144 <!-- 145 chassis locate and service LED's for X4500/X4540 146 --> 147 <facility name='fp.locate.led' type='indicator' provider='fac_prov_ipmi' > 148 <propgroup name='facility' version='1' name-stability='Private' data-stability='Private' > 149 <propval name='entity_ref' type='string' value='fp.locate.led' /> 150 <propval name='type' type='uint32' value='1' /> 151 <propmethod name='ipmi_indicator_mode' version='0' 152 propname='mode' proptype='uint32' mutable='1' > 153 </propmethod> 154 </propgroup> 155 </facility> 156 <facility name='bp.locate.led' type='indicator' provider='fac_prov_ipmi' > 157 <propgroup name='facility' version='1' name-stability='Private' data-stability='Private' > 158 <propval name='entity_ref' type='string' value='bp.locate.led' /> 159 <propval name='type' type='uint32' value='1' /> 160 <propmethod name='ipmi_indicator_mode' version='0' 161 propname='mode' proptype='uint32' mutable='1' > 162 </propmethod> 163 </propgroup> 164 </facility> 165 <facility name='fp.alert.led' type='indicator' provider='fac_prov_ipmi' > 166 <propgroup name='facility' version='1' name-stability='Private' data-stability='Private' > 167 <propval name='entity_ref' type='string' value='fp.alert.led' /> 168 <propval name='type' type='uint32' value='0' /> 169 <propmethod name='ipmi_indicator_mode' version='0' 170 propname='mode' proptype='uint32' mutable='1' > 171 </propmethod> 172 </propgroup> 173 </facility> 174 <facility name='bp.alert.led' type='indicator' provider='fac_prov_ipmi' > 175 <propgroup name='facility' version='1' name-stability='Private' data-stability='Private' > 176 <propval name='entity_ref' type='string' value='bp.alert.led' /> 177 <propval name='type' type='uint32' value='0' /> 178 <propmethod name='ipmi_indicator_mode' version='0' 179 propname='mode' proptype='uint32' mutable='1' > 180 </propmethod> 181 </propgroup> 182 </facility> 183 <facility name='sys.top_svc.led' type='indicator' provider='fac_prov_ipmi' > 184 <propgroup name='facility' version='1' name-stability='Private' data-stability='Private' > 185 <propval name='entity_ref' type='string' value='sys.top_svc.led' /> 186 <propval name='type' type='uint32' value='0' /> 187 <propmethod name='ipmi_indicator_mode' version='0' 188 propname='mode' proptype='uint32' mutable='1' > 189 </propmethod> 190 </propgroup> 191 </facility> 192 <facility name='sys.rear_svc.led' type='indicator' provider='fac_prov_ipmi' > 193 <propgroup name='facility' version='1' name-stability='Private' data-stability='Private' > 194 <propval name='entity_ref' type='string' value='sys.rear_svc.led' /> 195 <propval name='type' type='uint32' value='0' /> 196 <propmethod name='ipmi_indicator_mode' version='0' 197 propname='mode' proptype='uint32' mutable='1' > 198 </propmethod> 199 </propgroup> 200 </facility> 201 </set> 202 <set type='product' setlist='Sun-Fire-X4600-M2'> 203 <fac-enum provider='fac_prov_ipmi' /> 204 <propgroup name='ipmi' version='1' 205 name-stability='Private' data-stability='Private' > 206 <propval name='entity_ref' type='string' value='sys.intsw' /> 207 </propgroup> 208 <!-- 209 chassis locate and service LED's for X4600M2 210 --> 211 <facility name='sys.locate.led' type='indicator' provider='fac_prov_ipmi' > 212 <propgroup name='facility' version='1' name-stability='Private' data-stability='Private' > 213 <propval name='entity_ref' type='string' value='sys.locate.led' /> 214 <propval name='type' type='uint32' value='1' /> 215 <propmethod name='ipmi_indicator_mode' version='0' 216 propname='mode' proptype='uint32' mutable='1' > 217 </propmethod> 218 </propgroup> 219 </facility> 220 <facility name='sys.alert.led' type='indicator' provider='fac_prov_ipmi' > 221 <propgroup name='facility' version='1' name-stability='Private' data-stability='Private' > 222 <propval name='entity_ref' type='string' value='sys.alert.led' /> 223 <propval name='type' type='uint32' value='0' /> 224 <propmethod name='ipmi_indicator_mode' version='0' 225 propname='mode' proptype='uint32' mutable='1' > 226 </propmethod> 227 </propgroup> 228 </facility> 229 </set> 230 </node> 231 <dependents grouping='children'> 232 233 <set type='product' setlist='Sun-Fire-X4100-Server|Sun-Fire-X4200-Server|Sun-Fire-X4100-M2|Sun-Fire-X4200-M2|Sun-Fire-X4140|Sun-Fire-X4240|Sun-Fire-X4440'> 234 <range name='psu' min='0' max='100'> 235 <enum-method name='ipmi' version='1' /> 236 <propmap name='psu' /> 237 </range> 238 <range name='fanmodule' min='0' max='100'> 239 <propmap name='fan' /> 240 </range> 241 <set type='product' setlist='Sun-Fire-X4200-M2'> 242 <range name='bay' min='0' max='3'> 243 <propmap name='Sun-Fire-X4200-M2-disk' /> 244 </range> 245 </set> 246 <set type='product' setlist='Sun-Fire-X4200-Server'> 247 <range name='bay' min='0' max='3'> 248 <propmap name='Sun-Fire-X4200-Server-disk' /> 249 </range> 250 </set> 251 <set type='product' setlist='default'> 252 <range name='bay' min='0' max='1024'> 253 <enum-method name='ses' version='1' /> 254 </range> 255 </set> 256 </set> 257 258 <set type='product' setlist='Sun-Fire-X4500|Sun-Fire-X4540|SUN-FIRE-X4150|SUN-FIRE-X4250'> 259 <range name='psu' min='0' max='100'> 260 <propmap name='psu' /> 261 </range> 262 <range name='fanmodule' min='0' max='100'> 263 <propmap name='fan' /> 264 </range> 265 <set type='product' setlist='Sun-Fire-X4500'> 266 <range name='bay' min='0' max='47'> 267 <propmap name='Sun-Fire-X4500-disk' /> 268 </range> 269 </set> 270 <set type='product' setlist='Sun-Fire-X4540'> 271 <range name='bay' min='0' max='47'> 272 <propmap name='Sun-Fire-X4540-disk' /> 273 </range> 274 </set> 275 </set> 276 277 <set type='product' setlist='Sun-Fire-X4600|Sun-Fire-X4600-M2'> 278 <range name='psu' min='0' max='100'> 279 <enum-method name='ipmi' version='1' /> 280 <propmap name='psu' /> 281 </range> 282 <range name='fan' min='0' max='3'> 283 <propmap name='fan' /> 284 </range> 285 <range name='bay' min='0' max='3'> 286 <propmap name='Sun-Fire-X4600-M2-disk' /> 287 </range> 288 </set> 289 290 <set type='product' setlist='default'> 291 <range name='psu' min='0' max='100'> 292 <enum-method name='ipmi' version='1' /> 293 </range> 294 <range name='fan' min='0' max='100'> 295 <enum-method name='ipmi' version='1' /> 296 </range> 297 <range name='bay' min='0' max='1024'> 298 <enum-method name='ses' version='1' /> 299 </range> 300 </set> 301 302 </dependents> 303 304 </range> 305 306 <range name='ses-enclosure' min='0' max='1024'> 307 <enum-method name='ses' version='1' /> 308 </range> 309 310</topology> 311