xref: /titanic_41/usr/src/cmd/lvm/rpc.mdcommd/mdcomm.xml (revision 2a796556e7d6dfb15a985d4d879c73b491b7ae11)
1<?xml version='1.0'?>
2<!DOCTYPE service_bundle SYSTEM '/usr/share/lib/xml/dtd/service_bundle.dtd.1'>
3<!--
4 Copyright 2015 Nexenta Systems, Inc.  All rights reserved.
5
6 Copyright 2009 Sun Microsystems, Inc.  All rights reserved.
7 Use is subject to license terms.
8
9 CDDL HEADER START
10
11 The contents of this file are subject to the terms of the
12 Common Development and Distribution License (the "License").
13 You may not use this file except in compliance with the License.
14
15 You can obtain a copy of the license at usr/src/OPENSOLARIS.LICENSE
16 or http://www.opensolaris.org/os/licensing.
17 See the License for the specific language governing permissions
18 and limitations under the License.
19
20 When distributing Covered Code, include this CDDL HEADER in each
21 file and include the License file at usr/src/OPENSOLARIS.LICENSE.
22 If applicable, add the following below this CDDL HEADER, with the
23 fields enclosed by brackets "[]" replaced with your own identifying
24 information: Portions Copyright [yyyy] [name of copyright owner]
25
26 CDDL HEADER END
27
28	NOTE:  This service manifest is not editable; its contents will
29	be overwritten by package or patch operations, including
30	operating system upgrade.  Make customizations in a different
31	file.
32
33	Service manifest for the SVM multi node communication daemon
34-->
35
36<service_bundle type='manifest' name='SUNWmdr:mdcommd'>
37
38<service
39	name='network/rpc/mdcomm'
40	type='service'
41	version='1'>
42
43	<create_default_instance enabled='false' />
44
45	<restarter>
46		<service_fmri value='svc:/network/inetd:default' />
47	</restarter>
48
49	<dependency name='rpcbind'
50	    grouping='require_all'
51	    restart_on='restart'
52	    type='service'>
53		<service_fmri value='svc:/network/rpc/bind' />
54	</dependency>
55
56	<exec_method
57		type='method'
58		name='inetd_start'
59		exec='/usr/sbin/rpc.mdcommd'
60		timeout_seconds='0'>
61		<method_context>
62			<method_credential user='root' group='other' />
63		</method_context>
64	</exec_method>
65
66	<exec_method
67		type='method'
68		name='inetd_offline'
69		exec=':kill_process'
70		timeout_seconds='0'>
71	</exec_method>
72
73	<exec_method
74		type='method'
75		name='inetd_disable'
76		exec=':kill'
77		timeout_seconds='0'>
78	</exec_method>
79
80	<property_group name='inetd' type='framework'>
81		<propval name='name' type='astring' value='100422' />
82		<propval name='endpoint_type' type='astring' value='tli' />
83		<propval name='wait' type='boolean' value='true' />
84		<propval name='isrpc' type='boolean' value='true' />
85		<propval name='rpc_low_version' type='integer' value='2' />
86		<propval name='rpc_high_version' type='integer' value='2' />
87		<propval name='proto' type='astring' value='tcp' />
88		<propval name='connection_backlog' type='integer' value='32' />
89	</property_group>
90
91	<property_group name='firewall_config' type='com.sun,fw_configuration'>
92		<propval name='policy' type='astring' value='use_global' />
93		<propval name='apply_to' type='astring' value='' />
94		<propval name='exceptions' type='astring' value='' />
95		<propval name='value_authorization' type='astring'
96			value='solaris.smf.value.firewall.config' />
97	</property_group>
98
99	<stability value='Unstable' />
100
101	<template>
102		<common_name>
103			<loctext xml:lang='C'>
104			SVM multi-node communications
105			</loctext>
106		</common_name>
107		<documentation>
108			<manpage title='rpc.mdcommd' section='1M'
109			    manpath='/usr/share/man' />
110		</documentation>
111	</template>
112</service>
113
114</service_bundle>
115