1# 2# Copyright 2005 Sun Microsystems, Inc. All rights reserved. 3# Use is subject to license terms. 4# 5# CDDL HEADER START 6# 7# The contents of this file are subject to the terms of the 8# Common Development and Distribution License, Version 1.0 only 9# (the "License"). You may not use this file except in compliance 10# with the License. 11# 12# You can obtain a copy of the license at usr/src/OPENSOLARIS.LICENSE 13# or http://www.opensolaris.org/os/licensing. 14# See the License for the specific language governing permissions 15# and limitations under the License. 16# 17# When distributing Covered Code, include this CDDL HEADER in each 18# file and include the License file at usr/src/OPENSOLARIS.LICENSE. 19# If applicable, add the following below this CDDL HEADER, with the 20# fields enclosed by brackets "[]" replaced with your own identifying 21# information: Portions Copyright [yyyy] [name of copyright owner] 22# 23# CDDL HEADER END 24# 25#ident "%Z%%M% %I% %E% SMI" 26# 27# code: SUNOS-8000-0G 28# keys: ereport.sunos.unix.fm_panic 29# 30msgid "SUNOS-8000-0G.type" 31msgstr "Error" 32msgid "SUNOS-8000-0G.severity" 33msgstr "Major" 34msgid "SUNOS-8000-0G.description" 35msgstr "Errors have been detected that require a reboot to ensure system integrity. Refer to %s for more information." 36msgid "SUNOS-8000-0G.response" 37msgstr "Solaris will attempt to save and diagnose the error telemetry" 38msgid "SUNOS-8000-0G.impact" 39msgstr "The system will sync files, save a crash dump if needed, and reboot" 40msgid "SUNOS-8000-0G.action" 41msgstr "Save the error summary below in case telemetry cannot be saved" 42# 43# code: SUNOS-8000-1L 44# keys: defect.sunos.eft.undiagnosable_problem 45# 46msgid "SUNOS-8000-1L.type" 47msgstr "Defect" 48msgid "SUNOS-8000-1L.severity" 49msgstr "Minor" 50msgid "SUNOS-8000-1L.description" 51msgstr "The EFT Diagnosis Engine encountered telemetry for which it is unable to produce a diagnosis. This may indicate an incomplete EFT file provided or a defect in the diagnosis algorithm. Refer to %s for more information." 52msgid "SUNOS-8000-1L.response" 53msgstr "Error reports from the component will be logged for examination by Sun." 54msgid "SUNOS-8000-1L.impact" 55msgstr "Automated diagnosis and response for these events will not occur." 56msgid "SUNOS-8000-1L.action" 57msgstr "Run pkgchk -n SUNWfmd to ensure that fault management software is installed properly. Contact Sun for support." 58# 59# code: SUNOS-8000-20 60# keys: defect.io.pci.driver fault.io.pci.device fault.io.pci.bus 61# 62msgid "SUNOS-8000-20.type" 63msgstr "Fault" 64msgid "SUNOS-8000-20.severity" 65msgstr "Critical" 66msgid "SUNOS-8000-20.description" 67msgstr "A problem was detected in the SUNOS subsystem or controlling software" 68msgid "SUNOS-8000-20.response" 69msgstr "One or more of device instances may be disabled" 70msgid "SUNOS-8000-20.impact" 71msgstr "Loss of services provided by the device instances associated with this fault" 72msgid "SUNOS-8000-20.action" 73msgstr "Ensure latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support." 74 75# 76# code: SUNOS-8000-3V 77# keys: fault.io.pci.bus fault.io.pci.device 78# 79msgid "SUNOS-8000-3V.type" 80msgstr "Fault" 81msgid "SUNOS-8000-3V.severity" 82msgstr "Critical" 83msgid "SUNOS-8000-3V.description" 84msgstr "A problem was detected in the PCI subsystem" 85msgid "SUNOS-8000-3V.response" 86msgstr "One or more of device instances may be disabled" 87msgid "SUNOS-8000-3V.impact" 88msgstr "Loss of services provided by the device instances associated with this fault" 89msgid "SUNOS-8000-3V.action" 90msgstr "Schedule a repair procedure to replace the affected device. Use fmdump -v -u <EVENT_ID> to identify the device or contact Sun for support." 91 92# 93# code: SUNOS-8000-46 94# keys: defect.io.pci.driver fault.io.pci.device 95# 96msgid "SUNOS-8000-46.type" 97msgstr "Fault" 98msgid "SUNOS-8000-46.severity" 99msgstr "Critical" 100msgid "SUNOS-8000-46.description" 101msgstr "A problem was detected in the PCI subsystem or controlling software" 102msgid "SUNOS-8000-46.response" 103msgstr "One or more of device instances may be disabled" 104msgid "SUNOS-8000-46.impact" 105msgstr "Loss of services provided by the device instances associated with this fault" 106msgid "SUNOS-8000-46.action" 107msgstr "Ensure latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support." 108 109# 110# code: SUNOS-8000-5T 111# keys: defect.io.pci.driver fault.io.pci.bus 112# 113msgid "SUNOS-8000-5T.type" 114msgstr "Fault" 115msgid "SUNOS-8000-5T.severity" 116msgstr "Critical" 117msgid "SUNOS-8000-5T.description" 118msgstr "A problem was detected in the PCI subsystem or controlling software" 119msgid "SUNOS-8000-5T.response" 120msgstr "One or more of device instances may be disabled" 121msgid "SUNOS-8000-5T.impact" 122msgstr "Loss of services provided by the device instances associated with this fault" 123msgid "SUNOS-8000-5T.action" 124msgstr "Ensure latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support." 125 126# 127# code: SUNOS-8000-69 128# keys: fault.io.pci.device 129# 130msgid "SUNOS-8000-69.type" 131msgstr "Fault" 132msgid "SUNOS-8000-69.severity" 133msgstr "Critical" 134msgid "SUNOS-8000-69.description" 135msgstr "A problem was detected for a PCI controller" 136msgid "SUNOS-8000-69.response" 137msgstr "One or more of device instances may be disabled" 138msgid "SUNOS-8000-69.impact" 139msgstr "Loss of services provided by the device instances associated with this fault" 140msgid "SUNOS-8000-69.action" 141msgstr "Schedule a repair procedure to replace the affected device. Use fmdump -v -u <EVENT_ID> to identify the device or contact Sun for support." 142 143# 144# code: SUNOS-8000-7N 145# keys: fault.io.pci.bus 146# 147msgid "SUNOS-8000-7N.type" 148msgstr "Fault" 149msgid "SUNOS-8000-7N.severity" 150msgstr "Critical" 151msgid "SUNOS-8000-7N.description" 152msgstr "A problem was detected for a PCI bus" 153msgid "SUNOS-8000-7N.response" 154msgstr "One or more of device instances may be disabled" 155msgid "SUNOS-8000-7N.impact" 156msgstr "Loss of services provided by the device instances associated with this fault" 157msgid "SUNOS-8000-7N.action" 158msgstr "Schedule a repair procedure to replace the affected device. Use fmdump -v -u <EVENT_ID> to identify the device or contact Sun for support." 159 160# 161# code: SUNOS-8000-8W 162# keys: defect.io.pci.driver 163# 164# 165msgid "SUNOS-8000-8W.type" 166msgstr "Fault" 167msgid "SUNOS-8000-8W.severity" 168msgstr "Critical" 169msgid "SUNOS-8000-8W.description" 170msgstr "A problem was detected in the PCI controller software" 171msgid "SUNOS-8000-8W.response" 172msgstr "One or more of device instances may be disabled" 173msgid "SUNOS-8000-8W.impact" 174msgstr "Loss of services provided by the device instances associated with this fault" 175msgid "SUNOS-8000-8W.action" 176msgstr "Ensure latest drivers and patches are installed. Use fmdump -v -u <EVENT_ID> to identify the module/package, or contact Sun for support." 177