1# 2# Copyright 2005 Sun Microsystems, Inc. All rights reserved. 3# Use is subject to license terms. 4# 5# CDDL HEADER START 6# 7# The contents of this file are subject to the terms of the 8# Common Development and Distribution License, Version 1.0 only 9# (the "License"). You may not use this file except in compliance 10# with the License. 11# 12# You can obtain a copy of the license at usr/src/OPENSOLARIS.LICENSE 13# or http://www.opensolaris.org/os/licensing. 14# See the License for the specific language governing permissions 15# and limitations under the License. 16# 17# When distributing Covered Code, include this CDDL HEADER in each 18# file and include the License file at usr/src/OPENSOLARIS.LICENSE. 19# If applicable, add the following below this CDDL HEADER, with the 20# fields enclosed by brackets "[]" replaced with your own identifying 21# information: Portions Copyright [yyyy] [name of copyright owner] 22# 23# CDDL HEADER END 24# 25#ident "%Z%%M% %I% %E% SMI" 26# 27# DO NOT EDIT -- this file is generated by the Event Registry. 28# 29# 30# code: SUN4V-8000-1S 31# keys: fault.cpu.ultraSPARC-T1.ireg 32# 33msgid "SUN4V-8000-1S.type" 34msgstr "Fault" 35msgid "SUN4V-8000-1S.severity" 36msgstr "Minor" 37msgid "SUN4V-8000-1S.description" 38msgstr "The number of errors associated with this CPU has exceeded \n acceptable levels. Refer to %s for more information." 39msgid "SUN4V-8000-1S.response" 40msgstr "The fault manager will attempt to remove the affected CPU from service." 41msgid "SUN4V-8000-1S.impact" 42msgstr "System performance may be affected." 43msgid "SUN4V-8000-1S.action" 44msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>." 45# 46# code: SUN4V-8000-2A 47# keys: fault.cpu.ultraSPARC-T1.freg 48# 49msgid "SUN4V-8000-2A.type" 50msgstr "Fault" 51msgid "SUN4V-8000-2A.severity" 52msgstr "Major" 53msgid "SUN4V-8000-2A.description" 54msgstr "The number of errors associated with this CPU has exceeded \n acceptable levels. Refer to %s for more information." 55msgid "SUN4V-8000-2A.response" 56msgstr "None" 57msgid "SUN4V-8000-2A.impact" 58msgstr "System performance may be affected." 59msgid "SUN4V-8000-2A.action" 60msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>." 61# 62# code: SUN4V-8000-3P 63# keys: fault.cpu.ultraSPARC-T1.itlb 64# 65msgid "SUN4V-8000-3P.type" 66msgstr "Fault" 67msgid "SUN4V-8000-3P.severity" 68msgstr "Minor" 69msgid "SUN4V-8000-3P.description" 70msgstr "The number of errors associated with this CPU has exceeded \n acceptable levels. Refer to %s for more information." 71msgid "SUN4V-8000-3P.response" 72msgstr "The fault manager will attempt to remove the affected CPU from service." 73msgid "SUN4V-8000-3P.impact" 74msgstr "System performance may be affected.\n" 75msgid "SUN4V-8000-3P.action" 76msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>." 77# 78# code: SUN4V-8000-4D 79# keys: fault.cpu.ultraSPARC-T1.dtlb 80# 81msgid "SUN4V-8000-4D.type" 82msgstr "Fault" 83msgid "SUN4V-8000-4D.severity" 84msgstr "Minor" 85msgid "SUN4V-8000-4D.description" 86msgstr "The number of errors associated with this CPU has exceeded \n acceptable levels. Refer to %s for more information." 87msgid "SUN4V-8000-4D.response" 88msgstr "The fault manager will attempt to remove the affected CPU from service." 89msgid "SUN4V-8000-4D.impact" 90msgstr "System performance may be affected.\n" 91msgid "SUN4V-8000-4D.action" 92msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>." 93# 94# code: SUN4V-8000-5H 95# keys: fault.cpu.ultraSPARC-T1.icache 96# 97msgid "SUN4V-8000-5H.type" 98msgstr "Fault" 99msgid "SUN4V-8000-5H.severity" 100msgstr "Minor" 101msgid "SUN4V-8000-5H.description" 102msgstr "The number of errors associated with this CPU has exceeded \n acceptable levels. Refer to %s for more information." 103msgid "SUN4V-8000-5H.response" 104msgstr "The fault manager will attempt to remove the affected CPU from service." 105msgid "SUN4V-8000-5H.impact" 106msgstr "System performance may be affected.\n" 107msgid "SUN4V-8000-5H.action" 108msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>." 109# 110# code: SUN4V-8000-63 111# keys: fault.cpu.ultraSPARC-T1.dcache 112# 113msgid "SUN4V-8000-63.type" 114msgstr "Fault" 115msgid "SUN4V-8000-63.severity" 116msgstr "Minor" 117msgid "SUN4V-8000-63.description" 118msgstr "The number of errors associated with this CPU has exceeded \n acceptable levels. Refer to %s for more information." 119msgid "SUN4V-8000-63.response" 120msgstr "The fault manager will attempt to remove the affected CPU from service." 121msgid "SUN4V-8000-63.impact" 122msgstr "System performance may be affected.\n" 123msgid "SUN4V-8000-63.action" 124msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>." 125# 126# code: SUN4V-8000-7Y 127# keys: fault.cpu.ultraSPARC-T1.mau 128# 129msgid "SUN4V-8000-7Y.type" 130msgstr "Fault" 131msgid "SUN4V-8000-7Y.severity" 132msgstr "Major" 133msgid "SUN4V-8000-7Y.description" 134msgstr "The number of errors associated with this CPU has exceeded \n acceptable levels. Refer to %s for more information." 135msgid "SUN4V-8000-7Y.response" 136msgstr "None" 137msgid "SUN4V-8000-7Y.impact" 138msgstr "System performance may be affected.\n" 139msgid "SUN4V-8000-7Y.action" 140msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>." 141# 142# code: SUN4V-8000-8Q 143# keys: fault.cpu.ultraSPARC-T1.l2cachedata 144# 145msgid "SUN4V-8000-8Q.type" 146msgstr "Fault" 147msgid "SUN4V-8000-8Q.severity" 148msgstr "Critical" 149msgid "SUN4V-8000-8Q.description" 150msgstr "The number of errors associated with this CPU has exceeded \n acceptable levels. Refer to %s for more information." 151msgid "SUN4V-8000-8Q.response" 152msgstr "None" 153msgid "SUN4V-8000-8Q.impact" 154msgstr "System performance may be affected.\n" 155msgid "SUN4V-8000-8Q.action" 156msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>." 157# 158# code: SUN4V-8000-9C 159# keys: fault.cpu.ultraSPARC-T1.l2cachetag 160# 161msgid "SUN4V-8000-9C.type" 162msgstr "Fault" 163msgid "SUN4V-8000-9C.severity" 164msgstr "Critical" 165msgid "SUN4V-8000-9C.description" 166msgstr "The number of errors associated with this CPU has exceeded \n acceptable levels. Refer to %s for more information." 167msgid "SUN4V-8000-9C.response" 168msgstr "None" 169msgid "SUN4V-8000-9C.impact" 170msgstr "System performance may be affected.\n" 171msgid "SUN4V-8000-9C.action" 172msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>." 173# 174# code: SUN4V-8000-AR 175# keys: fault.cpu.ultraSPARC-T1.l2cachectl 176# 177msgid "SUN4V-8000-AR.type" 178msgstr "Fault" 179msgid "SUN4V-8000-AR.severity" 180msgstr "Critical" 181msgid "SUN4V-8000-AR.description" 182msgstr "The number of errors associated with this CPU has exceeded \n acceptable levels. Refer to %s for more information." 183msgid "SUN4V-8000-AR.response" 184msgstr "None" 185msgid "SUN4V-8000-AR.impact" 186msgstr "System performance may be affected.\n" 187msgid "SUN4V-8000-AR.action" 188msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>." 189# 190# code: SUN4V-8000-C4 191# keys: fault.memory.page 192# 193msgid "SUN4V-8000-C4.type" 194msgstr "Fault" 195msgid "SUN4V-8000-C4.severity" 196msgstr "Minor" 197msgid "SUN4V-8000-C4.description" 198msgstr "The number of errors associated with this memory module continues to exceed acceptable levels. Refer to %s for more information." 199msgid "SUN4V-8000-C4.response" 200msgstr "An attempt will be made to remove this memory page from service." 201msgid "SUN4V-8000-C4.impact" 202msgstr "The performance of the system may be minimally impacted as a result of removing the memory page from operation." 203msgid "SUN4V-8000-C4.action" 204msgstr "No repair action is recommended at this time." 205# 206# code: SUN4V-8000-DX 207# keys: fault.memory.dimm 208# 209msgid "SUN4V-8000-DX.type" 210msgstr "Fault" 211msgid "SUN4V-8000-DX.severity" 212msgstr "Major" 213msgid "SUN4V-8000-DX.description" 214msgstr "The number of errors associated with this memory module has exceeded acceptable levels. Refer to %s for more information." 215msgid "SUN4V-8000-DX.response" 216msgstr "Pages of memory associated with this memory module are being removed from service as errors are reported." 217msgid "SUN4V-8000-DX.impact" 218msgstr "Total system memory capacity will be reduced as pages are retired." 219msgid "SUN4V-8000-DX.action" 220msgstr "Schedule a repair procedure to replace the affected memory module. Use fmdump -v -u <EVENT_ID> to identify the module." 221# 222# code: SUN4V-8000-E2 223# keys: fault.memory.bank 224# 225msgid "SUN4V-8000-E2.type" 226msgstr "Fault" 227msgid "SUN4V-8000-E2.severity" 228msgstr "Critical" 229msgid "SUN4V-8000-E2.description" 230msgstr "The number of errors associated with this memory module has exceeded acceptable levels. Refer to %s for more information." 231msgid "SUN4V-8000-E2.response" 232msgstr "Pages of memory associated with this memory module are being removed from service as errors are reported." 233msgid "SUN4V-8000-E2.impact" 234msgstr "Total system memory capacity will be reduced as pages are retired." 235msgid "SUN4V-8000-E2.action" 236msgstr "Schedule a repair procedure to replace the affected memory module. Use fmdump -v -u <EVENT_ID> to identify the module." 237