1# 2# Copyright 2009 Sun Microsystems, Inc. All rights reserved. 3# Use is subject to license terms. 4# 5# CDDL HEADER START 6# 7# The contents of this file are subject to the terms of the 8# Common Development and Distribution License (the "License"). 9# You may not use this file except in compliance with the License. 10# 11# You can obtain a copy of the license at usr/src/OPENSOLARIS.LICENSE 12# or http://www.opensolaris.org/os/licensing. 13# See the License for the specific language governing permissions 14# and limitations under the License. 15# 16# When distributing Covered Code, include this CDDL HEADER in each 17# file and include the License file at usr/src/OPENSOLARIS.LICENSE. 18# If applicable, add the following below this CDDL HEADER, with the 19# fields enclosed by brackets "[]" replaced with your own identifying 20# information: Portions Copyright [yyyy] [name of copyright owner] 21# 22# CDDL HEADER END 23# 24# DO NOT EDIT -- this file is generated by the Event Registry. 25# 26# 27# code: SUN4V-8000-1S 28# keys: fault.cpu.ultraSPARC-T1.ireg 29# 30msgid "SUN4V-8000-1S.type" 31msgstr "Fault" 32msgid "SUN4V-8000-1S.severity" 33msgstr "Minor" 34msgid "SUN4V-8000-1S.description" 35msgstr "The number of errors associated with this CPU has exceeded \n acceptable levels. Refer to %s for more information." 36msgid "SUN4V-8000-1S.response" 37msgstr "The fault manager will attempt to remove the affected CPU from service." 38msgid "SUN4V-8000-1S.impact" 39msgstr "System performance may be affected." 40msgid "SUN4V-8000-1S.action" 41msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>." 42# 43# code: SUN4V-8000-2A 44# keys: fault.cpu.ultraSPARC-T1.freg 45# 46msgid "SUN4V-8000-2A.type" 47msgstr "Fault" 48msgid "SUN4V-8000-2A.severity" 49msgstr "Major" 50msgid "SUN4V-8000-2A.description" 51msgstr "The number of errors associated with this CPU has exceeded \n acceptable levels. Refer to %s for more information." 52msgid "SUN4V-8000-2A.response" 53msgstr "None" 54msgid "SUN4V-8000-2A.impact" 55msgstr "System performance may be affected." 56msgid "SUN4V-8000-2A.action" 57msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>." 58# 59# code: SUN4V-8000-3P 60# keys: fault.cpu.ultraSPARC-T1.itlb 61# 62msgid "SUN4V-8000-3P.type" 63msgstr "Fault" 64msgid "SUN4V-8000-3P.severity" 65msgstr "Minor" 66msgid "SUN4V-8000-3P.description" 67msgstr "The number of errors associated with this CPU has exceeded \n acceptable levels. Refer to %s for more information." 68msgid "SUN4V-8000-3P.response" 69msgstr "The fault manager will attempt to remove the affected CPU from service." 70msgid "SUN4V-8000-3P.impact" 71msgstr "System performance may be affected.\n" 72msgid "SUN4V-8000-3P.action" 73msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>." 74# 75# code: SUN4V-8000-4D 76# keys: fault.cpu.ultraSPARC-T1.dtlb 77# 78msgid "SUN4V-8000-4D.type" 79msgstr "Fault" 80msgid "SUN4V-8000-4D.severity" 81msgstr "Minor" 82msgid "SUN4V-8000-4D.description" 83msgstr "The number of errors associated with this CPU has exceeded \n acceptable levels. Refer to %s for more information." 84msgid "SUN4V-8000-4D.response" 85msgstr "The fault manager will attempt to remove the affected CPU from service." 86msgid "SUN4V-8000-4D.impact" 87msgstr "System performance may be affected.\n" 88msgid "SUN4V-8000-4D.action" 89msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>." 90# 91# code: SUN4V-8000-5H 92# keys: fault.cpu.ultraSPARC-T1.icache 93# 94msgid "SUN4V-8000-5H.type" 95msgstr "Fault" 96msgid "SUN4V-8000-5H.severity" 97msgstr "Minor" 98msgid "SUN4V-8000-5H.description" 99msgstr "The number of errors associated with this CPU has exceeded \n acceptable levels. Refer to %s for more information." 100msgid "SUN4V-8000-5H.response" 101msgstr "The fault manager will attempt to remove the affected CPU from service." 102msgid "SUN4V-8000-5H.impact" 103msgstr "System performance may be affected.\n" 104msgid "SUN4V-8000-5H.action" 105msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>." 106# 107# code: SUN4V-8000-63 108# keys: fault.cpu.ultraSPARC-T1.dcache 109# 110msgid "SUN4V-8000-63.type" 111msgstr "Fault" 112msgid "SUN4V-8000-63.severity" 113msgstr "Minor" 114msgid "SUN4V-8000-63.description" 115msgstr "The number of errors associated with this CPU has exceeded \n acceptable levels. Refer to %s for more information." 116msgid "SUN4V-8000-63.response" 117msgstr "The fault manager will attempt to remove the affected CPU from service." 118msgid "SUN4V-8000-63.impact" 119msgstr "System performance may be affected.\n" 120msgid "SUN4V-8000-63.action" 121msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>." 122# 123# code: SUN4V-8000-7Y 124# keys: fault.cpu.ultraSPARC-T1.mau 125# 126msgid "SUN4V-8000-7Y.type" 127msgstr "Fault" 128msgid "SUN4V-8000-7Y.severity" 129msgstr "Major" 130msgid "SUN4V-8000-7Y.description" 131msgstr "The number of errors associated with this CPU has exceeded \n acceptable levels. Refer to %s for more information." 132msgid "SUN4V-8000-7Y.response" 133msgstr "None" 134msgid "SUN4V-8000-7Y.impact" 135msgstr "System performance may be affected.\n" 136msgid "SUN4V-8000-7Y.action" 137msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>." 138# 139# code: SUN4V-8000-8Q 140# keys: fault.cpu.ultraSPARC-T1.l2cachedata 141# 142msgid "SUN4V-8000-8Q.type" 143msgstr "Fault" 144msgid "SUN4V-8000-8Q.severity" 145msgstr "Critical" 146msgid "SUN4V-8000-8Q.description" 147msgstr "The number of errors associated with this CPU has exceeded \n acceptable levels. Refer to %s for more information." 148msgid "SUN4V-8000-8Q.response" 149msgstr "None" 150msgid "SUN4V-8000-8Q.impact" 151msgstr "System performance may be affected.\n" 152msgid "SUN4V-8000-8Q.action" 153msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>." 154# 155# code: SUN4V-8000-9C 156# keys: fault.cpu.ultraSPARC-T1.l2cachetag 157# 158msgid "SUN4V-8000-9C.type" 159msgstr "Fault" 160msgid "SUN4V-8000-9C.severity" 161msgstr "Critical" 162msgid "SUN4V-8000-9C.description" 163msgstr "The number of errors associated with this CPU has exceeded \n acceptable levels. Refer to %s for more information." 164msgid "SUN4V-8000-9C.response" 165msgstr "None" 166msgid "SUN4V-8000-9C.impact" 167msgstr "System performance may be affected.\n" 168msgid "SUN4V-8000-9C.action" 169msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>." 170# 171# code: SUN4V-8000-AR 172# keys: fault.cpu.ultraSPARC-T1.l2cachectl 173# 174msgid "SUN4V-8000-AR.type" 175msgstr "Fault" 176msgid "SUN4V-8000-AR.severity" 177msgstr "Critical" 178msgid "SUN4V-8000-AR.description" 179msgstr "The number of errors associated with this CPU has exceeded \n acceptable levels. Refer to %s for more information." 180msgid "SUN4V-8000-AR.response" 181msgstr "None" 182msgid "SUN4V-8000-AR.impact" 183msgstr "System performance may be affected.\n" 184msgid "SUN4V-8000-AR.action" 185msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>." 186# 187# code: SUN4V-8000-C4 188# keys: fault.memory.page 189# 190msgid "SUN4V-8000-C4.type" 191msgstr "Fault" 192msgid "SUN4V-8000-C4.severity" 193msgstr "Minor" 194msgid "SUN4V-8000-C4.description" 195msgstr "The number of errors associated with this memory module continues to exceed acceptable levels. Refer to %s for more information." 196msgid "SUN4V-8000-C4.response" 197msgstr "An attempt will be made to remove this memory page from service." 198msgid "SUN4V-8000-C4.impact" 199msgstr "The performance of the system may be minimally impacted as a result of removing the memory page from operation." 200msgid "SUN4V-8000-C4.action" 201msgstr "No repair action is recommended at this time." 202# 203# code: SUN4V-8000-DX 204# keys: fault.memory.dimm 205# 206msgid "SUN4V-8000-DX.type" 207msgstr "Fault" 208msgid "SUN4V-8000-DX.severity" 209msgstr "Major" 210msgid "SUN4V-8000-DX.description" 211msgstr "The number of correctable errors associated with this memory module has exceeded acceptable levels. Refer to %s for more information." 212msgid "SUN4V-8000-DX.response" 213msgstr "Pages of memory associated with this memory module have been removed from service, up to a limit which has now been reached." 214msgid "SUN4V-8000-DX.impact" 215msgstr "Total system memory capacity has been reduced." 216msgid "SUN4V-8000-DX.action" 217msgstr "Schedule a repair procedure to replace the affected memory module. Use 'fmadm faulty' to identify the memory module." 218# 219# code: SUN4V-8000-E2 220# keys: fault.memory.bank 221# 222msgid "SUN4V-8000-E2.type" 223msgstr "Fault" 224msgid "SUN4V-8000-E2.severity" 225msgstr "Critical" 226msgid "SUN4V-8000-E2.description" 227msgstr "The number of errors associated with this memory module has exceeded acceptable levels. Refer to %s for more information." 228msgid "SUN4V-8000-E2.response" 229msgstr "Pages of memory associated with this memory module are being removed from service as errors are reported." 230msgid "SUN4V-8000-E2.impact" 231msgstr "Total system memory capacity will be reduced as pages are retired." 232msgid "SUN4V-8000-E2.action" 233msgstr "Schedule a repair procedure to replace the affected memory module. Use fmdump -v -u <EVENT_ID> to identify the module." 234# 235# code: SUN4V-8000-FJ 236# keys: fault.memory.link-c 237# 238msgid "SUN4V-8000-FJ.type" 239msgstr "Fault" 240msgid "SUN4V-8000-FJ.severity" 241msgstr "Major" 242msgid "SUN4V-8000-FJ.description" 243msgstr "A problem was detected in the interconnect between a memory DIMM module and\nits memory controller. \n Refer to %s for more information." 244msgid "SUN4V-8000-FJ.response" 245msgstr "No automated response.\n" 246msgid "SUN4V-8000-FJ.impact" 247msgstr "System performance may be impacted.\n" 248msgid "SUN4V-8000-FJ.action" 249msgstr "At convenient time, try reseating the memory module(s). If problem persists,\ncontact Sun to schedule part replacement.\n" 250# 251# code: SUN4V-8000-GE 252# keys: fault.cpu.ultraSPARC-T2.ireg 253# 254msgid "SUN4V-8000-GE.type" 255msgstr "Fault" 256msgid "SUN4V-8000-GE.severity" 257msgstr "Minor" 258msgid "SUN4V-8000-GE.description" 259msgstr "The number of integer register errors associated with this thread has exceeded acceptable levels.\n Refer to %s for more information." 260msgid "SUN4V-8000-GE.response" 261msgstr "The fault manager will attempt to remove the affected thread\nfrom service.\n" 262msgid "SUN4V-8000-GE.impact" 263msgstr "System performance may be affected. \n" 264msgid "SUN4V-8000-GE.action" 265msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n" 266# 267# code: SUN4V-8000-HP 268# keys: fault.cpu.ultraSPARC-T2.freg 269# 270msgid "SUN4V-8000-HP.type" 271msgstr "Fault" 272msgid "SUN4V-8000-HP.severity" 273msgstr "Minor" 274msgid "SUN4V-8000-HP.description" 275msgstr "The number of floating register errors associated with this thread has exceeded acceptable levels.\n Refer to %s for more information." 276msgid "SUN4V-8000-HP.response" 277msgstr "The fault manager will attempt to remove the affected thread\nfrom service.\n" 278msgid "SUN4V-8000-HP.impact" 279msgstr "System performance may be affected. \n" 280msgid "SUN4V-8000-HP.action" 281msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n" 282# 283# code: SUN4V-8000-JA 284# keys: fault.cpu.ultraSPARC-T2.misc_reg 285# 286msgid "SUN4V-8000-JA.type" 287msgstr "Fault" 288msgid "SUN4V-8000-JA.severity" 289msgstr "Minor" 290msgid "SUN4V-8000-JA.description" 291msgstr "The number of ancillary register errors associated with this thread has exceeded acceptable levels.\n Refer to %s for more information." 292msgid "SUN4V-8000-JA.response" 293msgstr "The fault manager will attempt to remove the affected thread\nfrom service.\n" 294msgid "SUN4V-8000-JA.impact" 295msgstr "System performance may be affected. \n" 296msgid "SUN4V-8000-JA.action" 297msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n" 298# 299# code: SUN4V-8000-KS 300# keys: fault.cpu.ultraSPARC-T2.itlb 301# 302msgid "SUN4V-8000-KS.type" 303msgstr "Fault" 304msgid "SUN4V-8000-KS.severity" 305msgstr "Major" 306msgid "SUN4V-8000-KS.description" 307msgstr "The number of ITLB errors associated with this thread has exceeded acceptable levels.\n Refer to %s for more information." 308msgid "SUN4V-8000-KS.response" 309msgstr "The fault manager will attempt to remove all threads associated with\nthis resource from service.\n" 310msgid "SUN4V-8000-KS.impact" 311msgstr "System performance is likely to be affected. \n" 312msgid "SUN4V-8000-KS.action" 313msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n" 314# 315# code: SUN4V-8000-L5 316# keys: fault.cpu.ultraSPARC-T2.dtlb 317# 318msgid "SUN4V-8000-L5.type" 319msgstr "Fault" 320msgid "SUN4V-8000-L5.severity" 321msgstr "Major" 322msgid "SUN4V-8000-L5.description" 323msgstr "The number of DTLB errors associated with this thread has exceeded acceptable levels.\n Refer to %s for more information." 324msgid "SUN4V-8000-L5.response" 325msgstr "The fault manager will attempt to remove all threads associated with\nthis resource from service.\n" 326msgid "SUN4V-8000-L5.impact" 327msgstr "System performance is likely to be affected. \n" 328msgid "SUN4V-8000-L5.action" 329msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n" 330# 331# code: SUN4V-8000-MY 332# keys: fault.cpu.ultraSPARC-T2.icache 333# 334msgid "SUN4V-8000-MY.type" 335msgstr "Fault" 336msgid "SUN4V-8000-MY.severity" 337msgstr "Major" 338msgid "SUN4V-8000-MY.description" 339msgstr "The number of I-cache errors associated with this thread has exceeded acceptable levels.\n Refer to %s for more information." 340msgid "SUN4V-8000-MY.response" 341msgstr "The fault manager will attempt to remove all threads associated with\nthis resource from service.\n" 342msgid "SUN4V-8000-MY.impact" 343msgstr "System performance is likely to be affected. \n" 344msgid "SUN4V-8000-MY.action" 345msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n" 346# 347# code: SUN4V-8000-N3 348# keys: fault.cpu.ultraSPARC-T2.dcache 349# 350msgid "SUN4V-8000-N3.type" 351msgstr "Fault" 352msgid "SUN4V-8000-N3.severity" 353msgstr "Major" 354msgid "SUN4V-8000-N3.description" 355msgstr "The number of D-cache errors associated with this thread has exceeded acceptable levels.\n Refer to %s for more information." 356msgid "SUN4V-8000-N3.response" 357msgstr "The fault manager will attempt to remove all threads associated with\nthis resource from service.\n" 358msgid "SUN4V-8000-N3.impact" 359msgstr "System performance is likely to be affected. \n" 360msgid "SUN4V-8000-N3.action" 361msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n" 362# 363# code: SUN4V-8000-PH 364# keys: fault.cpu.ultraSPARC-T2.mau 365# 366msgid "SUN4V-8000-PH.type" 367msgstr "Fault" 368msgid "SUN4V-8000-PH.severity" 369msgstr "Major" 370msgid "SUN4V-8000-PH.description" 371msgstr "The number of modular arithmetic unit errors associated with this unit has exceeded acceptable levels.\n Refer to %s for more information." 372msgid "SUN4V-8000-PH.response" 373msgstr "Cryptographic software will not use this modular arithmetic unit.\n" 374msgid "SUN4V-8000-PH.impact" 375msgstr "System performance is likely to be affected. \n" 376msgid "SUN4V-8000-PH.action" 377msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n" 378# 379# code: SUN4V-8000-QD 380# keys: fault.cpu.ultraSPARC-T2.l2data-c 381# 382msgid "SUN4V-8000-QD.type" 383msgstr "Fault" 384msgid "SUN4V-8000-QD.severity" 385msgstr "Critical" 386msgid "SUN4V-8000-QD.description" 387msgstr "The number of level 2 cache correctable data errors has exceeded acceptable levels.\n Refer to %s for more information." 388msgid "SUN4V-8000-QD.response" 389msgstr "No automated response.\n" 390msgid "SUN4V-8000-QD.impact" 391msgstr "System performance is likely to be affected. \n" 392msgid "SUN4V-8000-QD.action" 393msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n" 394# 395# code: SUN4V-8000-R4 396# keys: fault.cpu.ultraSPARC-T2.l2cachetag 397# 398msgid "SUN4V-8000-R4.type" 399msgstr "Fault" 400msgid "SUN4V-8000-R4.severity" 401msgstr "Critical" 402msgid "SUN4V-8000-R4.description" 403msgstr "The number of level 2 cache tag errors has exceeded acceptable levels.\n Refer to %s for more information." 404msgid "SUN4V-8000-R4.response" 405msgstr "No automated response.\n" 406msgid "SUN4V-8000-R4.impact" 407msgstr "System performance is likely to be affected. \n" 408msgid "SUN4V-8000-R4.action" 409msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n" 410# 411# code: SUN4V-8000-SR 412# keys: fault.cpu.ultraSPARC-T2.l2cachectl 413# 414msgid "SUN4V-8000-SR.type" 415msgstr "Fault" 416msgid "SUN4V-8000-SR.severity" 417msgstr "Critical" 418msgid "SUN4V-8000-SR.description" 419msgstr "The number of level 2 cache control errors has exceeded acceptable levels.\n Refer to %s for more information." 420msgid "SUN4V-8000-SR.response" 421msgstr "No automated response.\n" 422msgid "SUN4V-8000-SR.impact" 423msgstr "System performance is likely to be affected. System may be unstable.\n" 424msgid "SUN4V-8000-SR.action" 425msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n" 426# 427# code: SUN4V-8000-TC 428# keys: fault.memory.link-u 429# 430msgid "SUN4V-8000-TC.type" 431msgstr "Fault" 432msgid "SUN4V-8000-TC.severity" 433msgstr "Critical" 434msgid "SUN4V-8000-TC.description" 435msgstr "A problem was detected in the interconnect between a memory DIMM module and\nits memory controller. \n Refer to %s for more information." 436msgid "SUN4V-8000-TC.response" 437msgstr "No automated response.\n" 438msgid "SUN4V-8000-TC.impact" 439msgstr "System performance may be impacted.\n" 440msgid "SUN4V-8000-TC.action" 441msgstr "At convenient time, try reseating the memory module. If problem persists,\ncontact Sun to schedule part replacement.\n" 442# 443# code: SUN4V-8000-UQ 444# keys: fault.cpu.ultraSPARC-T2.l2data-u 445# 446msgid "SUN4V-8000-UQ.type" 447msgstr "Fault" 448msgid "SUN4V-8000-UQ.severity" 449msgstr "Critical" 450msgid "SUN4V-8000-UQ.description" 451msgstr "The number of level 2 cache uncorrectable data errors has exceeded acceptable levels.\n Refer to %s for more information." 452msgid "SUN4V-8000-UQ.response" 453msgstr "No automated response.\n" 454msgid "SUN4V-8000-UQ.impact" 455msgstr "System performance is likely to be affected. \n" 456msgid "SUN4V-8000-UQ.action" 457msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n" 458# 459# code: SUN4V-8000-VE 460# keys: fault.cpu.ultraSPARC-T1.l2data-c 461# 462msgid "SUN4V-8000-VE.type" 463msgstr "Fault" 464msgid "SUN4V-8000-VE.severity" 465msgstr "Critical" 466msgid "SUN4V-8000-VE.description" 467msgstr "The number of level 2 cache correctable data errors has exceeded acceptable levels.\n Refer to %s for more information." 468msgid "SUN4V-8000-VE.response" 469msgstr "No automated response.\n" 470msgid "SUN4V-8000-VE.impact" 471msgstr "System performance is likely to be affected. \n" 472msgid "SUN4V-8000-VE.action" 473msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n" 474# 475# code: SUN4V-8000-WJ 476# keys: fault.cpu.ultraSPARC-T1.l2data-u 477# 478msgid "SUN4V-8000-WJ.type" 479msgstr "Fault" 480msgid "SUN4V-8000-WJ.severity" 481msgstr "Critical" 482msgid "SUN4V-8000-WJ.description" 483msgstr "The number of level 2 cache uncorrectable data errors has exceeded acceptable levels.\n Refer to %s for more information." 484msgid "SUN4V-8000-WJ.response" 485msgstr "No automated response.\n" 486msgid "SUN4V-8000-WJ.impact" 487msgstr "System performance is likely to be affected. \n" 488msgid "SUN4V-8000-WJ.action" 489msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n" 490# 491# code: SUN4V-8000-X2 492# keys: fault.memory.datapath 493# 494msgid "SUN4V-8000-X2.type" 495msgstr "Fault" 496msgid "SUN4V-8000-X2.severity" 497msgstr "Major" 498msgid "SUN4V-8000-X2.description" 499msgstr "Errors have been detected on multiple memory modules, suggesting that a problem exists somewhere else in the system.\n Refer to %s for more information." 500msgid "SUN4V-8000-X2.response" 501msgstr "Error reports from the affected components will be logged for examination by Sun.\n" 502msgid "SUN4V-8000-X2.impact" 503msgstr "System performance and stability may be affected. \n" 504msgid "SUN4V-8000-X2.action" 505msgstr "Contact your service provider for further diagnosis.\n" 506# 507# code: SUN4V-8000-YX 508# keys: fault.io.n2.ncu 509# 510msgid "SUN4V-8000-YX.type" 511msgstr "Fault" 512msgid "SUN4V-8000-YX.severity" 513msgstr "Critical" 514msgid "SUN4V-8000-YX.description" 515msgstr "A problem was detected in the NCU subsystem of the N2's SOC\n Refer to %s for more information." 516msgid "SUN4V-8000-YX.response" 517msgstr "One or more device instances may be disabled\n" 518msgid "SUN4V-8000-YX.impact" 519msgstr "Loss of services provided by the device\ninstances associated with this fault\n" 520msgid "SUN4V-8000-YX.action" 521msgstr "Schedule a repair procedure to replace the affected\ndevice if necessary, or contact Sun for support.\n" 522# 523# code: SUN4V-8001-02 524# keys: fault.io.n2.dmu 525# 526msgid "SUN4V-8001-02.type" 527msgstr "Fault" 528msgid "SUN4V-8001-02.severity" 529msgstr "Critical" 530msgid "SUN4V-8001-02.description" 531msgstr "A problem was detected in the DMU subsystem of the N2's SOC\n Refer to %s for more information." 532msgid "SUN4V-8001-02.response" 533msgstr "One or more device instances may be disabled\n" 534msgid "SUN4V-8001-02.impact" 535msgstr "Loss of services provided by the device\ninstances associated with this fault\n" 536msgid "SUN4V-8001-02.action" 537msgstr "Schedule a repair procedure to replace the affected\ndevice if necessary, or contact Sun for support.\n" 538# 539# code: SUN4V-8001-1X 540# keys: fault.io.n2.niu 541# 542msgid "SUN4V-8001-1X.type" 543msgstr "Fault" 544msgid "SUN4V-8001-1X.severity" 545msgstr "Critical" 546msgid "SUN4V-8001-1X.description" 547msgstr "A problem was detected in the NIU subsystem of the N2's SOC\n Refer to %s for more information." 548msgid "SUN4V-8001-1X.response" 549msgstr "One or more device instances may be disabled\n" 550msgid "SUN4V-8001-1X.impact" 551msgstr "Loss of services provided by the device\ninstances associated with this fault\n" 552msgid "SUN4V-8001-1X.action" 553msgstr "Schedule a repair procedure to replace the affected\ndevice if necessary, or contact Sun for support.\n" 554# 555# code: SUN4V-8001-2E 556# keys: fault.io.n2.siu 557# 558msgid "SUN4V-8001-2E.type" 559msgstr "Fault" 560msgid "SUN4V-8001-2E.severity" 561msgstr "Critical" 562msgid "SUN4V-8001-2E.description" 563msgstr "A problem was detected in the SIU subsystem of the N2's SOC\n Refer to %s for more information." 564msgid "SUN4V-8001-2E.response" 565msgstr "One or more device instances may be disabled\n" 566msgid "SUN4V-8001-2E.impact" 567msgstr "Loss of services provided by the device\ninstances associated with this fault\n" 568msgid "SUN4V-8001-2E.action" 569msgstr "Schedule a repair procedure to replace the affected\ndevice if necessary, or contact Sun for support.\n" 570# 571# code: SUN4V-8001-3J 572# keys: fault.io.n2.soc 573# 574msgid "SUN4V-8001-3J.type" 575msgstr "Fault" 576msgid "SUN4V-8001-3J.severity" 577msgstr "Critical" 578msgid "SUN4V-8001-3J.description" 579msgstr "A problem was detected in N2's SOC\n Refer to %s for more information." 580msgid "SUN4V-8001-3J.response" 581msgstr "One or more device instances may be disabled\n" 582msgid "SUN4V-8001-3J.impact" 583msgstr "Loss of services provided by the device\ninstances associated with this fault\n" 584msgid "SUN4V-8001-3J.action" 585msgstr "Schedule a repair procedure to replace the affected\ndevice if necessary, or contact Sun for support.\n" 586# 587# code: SUN4V-8001-4C 588# keys: fault.io.n2.crossbar 589# 590msgid "SUN4V-8001-4C.type" 591msgstr "Fault" 592msgid "SUN4V-8001-4C.severity" 593msgstr "Critical" 594msgid "SUN4V-8001-4C.description" 595msgstr "A problem was detected in the crossbar of the N2's SOC\n Refer to %s for more information." 596msgid "SUN4V-8001-4C.response" 597msgstr "One or more device instances may be disabled\n" 598msgid "SUN4V-8001-4C.impact" 599msgstr "Loss of services provided by the device\ninstances associated with this fault\n" 600msgid "SUN4V-8001-4C.action" 601msgstr "Schedule a repair procedure to replace the affected\ndevice if necessary, or contact Sun for support.\n" 602# 603# code: SUN4V-8001-5Q 604# keys: fault.io.fire.fw-epkt fault.io.fire.sw-epkt fault.io.fire.sw-fw-mismatch 605# 606msgid "SUN4V-8001-5Q.type" 607msgstr "Fault" 608msgid "SUN4V-8001-5Q.severity" 609msgstr "Critical" 610msgid "SUN4V-8001-5Q.description" 611msgstr "An uncorrectable problem was detected in the IO hostbridge in which a mismatch\nin the SW and FW prevents the error to be properly handled.\n Refer to %s for more information." 612msgid "SUN4V-8001-5Q.response" 613msgstr "One or more device instances may be disabled\n" 614msgid "SUN4V-8001-5Q.impact" 615msgstr "Loss of services provided by the device\ninstances associated with this fault\n" 616msgid "SUN4V-8001-5Q.action" 617msgstr "Schedule a repair procedure to replace the affected\ndevice if necessary, or contact Sun for support.\n" 618# 619# code: SUN4V-8001-64 620# keys: fault.io.vf.ncx 621# 622msgid "SUN4V-8001-64.type" 623msgstr "Fault" 624msgid "SUN4V-8001-64.severity" 625msgstr "Critical" 626msgid "SUN4V-8001-64.description" 627msgstr "An uncorrectable problem was detected in the NCX subsystem.\n Refer to %s for more information." 628msgid "SUN4V-8001-64.response" 629msgstr "One or more device instances may be disabled\n" 630msgid "SUN4V-8001-64.impact" 631msgstr "Loss of services provided by the device\ninstances associated with this fault\n" 632msgid "SUN4V-8001-64.action" 633msgstr "Schedule a repair procedure to replace the affected\ndevice if necessary, or contact Sun for support.\n" 634# 635# code: SUN4V-8001-7R 636# keys: fault.memory.link-f 637# 638msgid "SUN4V-8001-7R.type" 639msgstr "Fault" 640msgid "SUN4V-8001-7R.severity" 641msgstr "Major" 642msgid "SUN4V-8001-7R.description" 643msgstr "A problem was detected in the interconnect between a memory DIMM module and\nits memory controller. A lane failover has taken place.\n Refer to %s for more information." 644msgid "SUN4V-8001-7R.response" 645msgstr "No automated response.\n" 646msgid "SUN4V-8001-7R.impact" 647msgstr "System performance may be impacted.\n" 648msgid "SUN4V-8001-7R.action" 649msgstr "At convenient time, try reseating the memory module(s). If problem persists,\ncontact Sun to schedule part replacement.\n" 650# 651# code: SUN4V-8001-8H 652# keys: fault.cpu.ultraSPARC-T2plus.ireg 653# 654msgid "SUN4V-8001-8H.type" 655msgstr "Fault" 656msgid "SUN4V-8001-8H.severity" 657msgstr "Minor" 658msgid "SUN4V-8001-8H.description" 659msgstr "The number of integer register errors associated with this thread has exceeded acceptable levels.\n Refer to %s for more information." 660msgid "SUN4V-8001-8H.response" 661msgstr "The fault manager will attempt to remove the affected thread\nfrom service.\n" 662msgid "SUN4V-8001-8H.impact" 663msgstr "System performance may be affected. \n" 664msgid "SUN4V-8001-8H.action" 665msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n" 666# 667# code: SUN4V-8001-9D 668# keys: fault.cpu.ultraSPARC-T2plus.freg 669# 670msgid "SUN4V-8001-9D.type" 671msgstr "Fault" 672msgid "SUN4V-8001-9D.severity" 673msgstr "Minor" 674msgid "SUN4V-8001-9D.description" 675msgstr "The number of floating register errors associated with this thread has exceeded acceptable levels.\n Refer to %s for more information." 676msgid "SUN4V-8001-9D.response" 677msgstr "The fault manager will attempt to remove the affected thread\nfrom service.\n" 678msgid "SUN4V-8001-9D.impact" 679msgstr "System performance may be affected. \n" 680msgid "SUN4V-8001-9D.action" 681msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n" 682# 683# code: SUN4V-8001-AY 684# keys: fault.cpu.ultraSPARC-T2plus.misc_reg 685# 686msgid "SUN4V-8001-AY.type" 687msgstr "Fault" 688msgid "SUN4V-8001-AY.severity" 689msgstr "Minor" 690msgid "SUN4V-8001-AY.description" 691msgstr "The number of ancillary register errors associated with this thread has exceeded acceptable levels.\n Refer to %s for more information." 692msgid "SUN4V-8001-AY.response" 693msgstr "The fault manager will attempt to remove the affected thread\nfrom service.\n" 694msgid "SUN4V-8001-AY.impact" 695msgstr "System performance may be affected. \n" 696msgid "SUN4V-8001-AY.action" 697msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n" 698# 699# code: SUN4V-8001-C3 700# keys: fault.cpu.ultraSPARC-T2plus.itlb 701# 702msgid "SUN4V-8001-C3.type" 703msgstr "Fault" 704msgid "SUN4V-8001-C3.severity" 705msgstr "Major" 706msgid "SUN4V-8001-C3.description" 707msgstr "The number of ITLB errors associated with this thread has exceeded acceptable levels.\n Refer to %s for more information." 708msgid "SUN4V-8001-C3.response" 709msgstr "The fault manager will attempt to remove all threads associated with\nthis resource from service.\n" 710msgid "SUN4V-8001-C3.impact" 711msgstr "System performance is likely to be affected. \n" 712msgid "SUN4V-8001-C3.action" 713msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n" 714# 715# code: SUN4V-8001-DS 716# keys: fault.cpu.ultraSPARC-T2plus.dtlb 717# 718msgid "SUN4V-8001-DS.type" 719msgstr "Fault" 720msgid "SUN4V-8001-DS.severity" 721msgstr "Major" 722msgid "SUN4V-8001-DS.description" 723msgstr "The number of DTLB errors associated with this thread has exceeded acceptable levels.\n Refer to %s for more information." 724msgid "SUN4V-8001-DS.response" 725msgstr "The fault manager will attempt to remove all threads associated with\nthis resource from service.\n" 726msgid "SUN4V-8001-DS.impact" 727msgstr "System performance is likely to be affected. \n" 728msgid "SUN4V-8001-DS.action" 729msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n" 730# 731# code: SUN4V-8001-E5 732# keys: fault.cpu.ultraSPARC-T2plus.icache 733# 734msgid "SUN4V-8001-E5.type" 735msgstr "Fault" 736msgid "SUN4V-8001-E5.severity" 737msgstr "Major" 738msgid "SUN4V-8001-E5.description" 739msgstr "The number of I-cache errors associated with this thread has exceeded acceptable levels.\n Refer to %s for more information." 740msgid "SUN4V-8001-E5.response" 741msgstr "The fault manager will attempt to remove all threads associated with\nthis resource from service.\n" 742msgid "SUN4V-8001-E5.impact" 743msgstr "System performance is likely to be affected. \n" 744msgid "SUN4V-8001-E5.action" 745msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n" 746# 747# code: SUN4V-8001-FP 748# keys: fault.cpu.ultraSPARC-T2plus.dcache 749# 750msgid "SUN4V-8001-FP.type" 751msgstr "Fault" 752msgid "SUN4V-8001-FP.severity" 753msgstr "Major" 754msgid "SUN4V-8001-FP.description" 755msgstr "The number of D-cache errors associated with this thread has exceeded acceptable levels.\n Refer to %s for more information." 756msgid "SUN4V-8001-FP.response" 757msgstr "The fault manager will attempt to remove all threads associated with\nthis resource from service.\n" 758msgid "SUN4V-8001-FP.impact" 759msgstr "System performance is likely to be affected. \n" 760msgid "SUN4V-8001-FP.action" 761msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n" 762# 763# code: SUN4V-8001-GA 764# keys: fault.cpu.ultraSPARC-T2plus.mau 765# 766msgid "SUN4V-8001-GA.type" 767msgstr "Fault" 768msgid "SUN4V-8001-GA.severity" 769msgstr "Major" 770msgid "SUN4V-8001-GA.description" 771msgstr "The number of modular arithmetic unit errors associated with this thread has exceeded acceptable levels.\n Refer to %s for more information." 772msgid "SUN4V-8001-GA.response" 773msgstr "Cryptographic software will not use this modular arithmetic unit.\n\n" 774msgid "SUN4V-8001-GA.impact" 775msgstr "System performance is likely to be affected. \n" 776msgid "SUN4V-8001-GA.action" 777msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n" 778# 779# code: SUN4V-8001-HJ 780# keys: fault.cpu.ultraSPARC-T2plus.l2data-c 781# 782msgid "SUN4V-8001-HJ.type" 783msgstr "Fault" 784msgid "SUN4V-8001-HJ.severity" 785msgstr "Critical" 786msgid "SUN4V-8001-HJ.description" 787msgstr "The number of level 2 cache correctable data errors has exceeded acceptable levels.\n Refer to %s for more information." 788msgid "SUN4V-8001-HJ.response" 789msgstr "No automated response.\n" 790msgid "SUN4V-8001-HJ.impact" 791msgstr "System performance is likely to be affected. \n" 792msgid "SUN4V-8001-HJ.action" 793msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n" 794# 795# code: SUN4V-8001-JE 796# keys: fault.cpu.ultraSPARC-T2plus.l2cachetag 797# 798msgid "SUN4V-8001-JE.type" 799msgstr "Fault" 800msgid "SUN4V-8001-JE.severity" 801msgstr "Critical" 802msgid "SUN4V-8001-JE.description" 803msgstr "The number of level 2 cache tag errors has exceeded acceptable levels.\n Refer to %s for more information." 804msgid "SUN4V-8001-JE.response" 805msgstr "No automated response.\n" 806msgid "SUN4V-8001-JE.impact" 807msgstr "System performance is likely to be affected. \n" 808msgid "SUN4V-8001-JE.action" 809msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n" 810# 811# code: SUN4V-8001-KX 812# keys: fault.cpu.ultraSPARC-T2plus.l2cachectl 813# 814msgid "SUN4V-8001-KX.type" 815msgstr "Fault" 816msgid "SUN4V-8001-KX.severity" 817msgstr "Critical" 818msgid "SUN4V-8001-KX.description" 819msgstr "The number of level 2 cache control errors has exceeded acceptable levels.\n Refer to %s for more information." 820msgid "SUN4V-8001-KX.response" 821msgstr "No automated response.\n" 822msgid "SUN4V-8001-KX.impact" 823msgstr "System performance is likely to be affected. System may be unstable.\n" 824msgid "SUN4V-8001-KX.action" 825msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n" 826# 827# code: SUN4V-8001-L2 828# keys: fault.cpu.ultraSPARC-T2plus.l2data-u 829# 830msgid "SUN4V-8001-L2.type" 831msgstr "Fault" 832msgid "SUN4V-8001-L2.severity" 833msgstr "Critical" 834msgid "SUN4V-8001-L2.description" 835msgstr "The number of level 2 cache uncorrectable data errors has exceeded acceptable levels.\n Refer to %s for more information." 836msgid "SUN4V-8001-L2.response" 837msgstr "No automated response.\n" 838msgid "SUN4V-8001-L2.impact" 839msgstr "System performance is likely to be affected. \n" 840msgid "SUN4V-8001-L2.action" 841msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n" 842# 843# code: SUN4V-8001-MR 844# keys: fault.cpu.ultraSPARC-T2plus.lfu-f 845# 846msgid "SUN4V-8001-MR.type" 847msgstr "Fault" 848msgid "SUN4V-8001-MR.severity" 849msgstr "Major" 850msgid "SUN4V-8001-MR.description" 851msgstr "A CPU chip's Link Framing Unit has stopped using a bad lane.\n Refer to %s for more information." 852msgid "SUN4V-8001-MR.response" 853msgstr "No other automated response.\n" 854msgid "SUN4V-8001-MR.impact" 855msgstr "The system's capacity to correct transmission errors between CPU chips has been reduced.\n" 856msgid "SUN4V-8001-MR.action" 857msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n" 858# 859# code: SUN4V-8001-N4 860# keys: fault.cpu.ultraSPARC-T2plus.lfu-p 861# 862msgid "SUN4V-8001-N4.type" 863msgstr "Fault" 864msgid "SUN4V-8001-N4.severity" 865msgstr "Major" 866msgid "SUN4V-8001-N4.description" 867msgstr "A CPU chip's Link Framing Unit has encountered a protocol error.\n Refer to %s for more information." 868msgid "SUN4V-8001-N4.response" 869msgstr "No automated response.\n" 870msgid "SUN4V-8001-N4.impact" 871msgstr "The system has most likely taken a fatal reset.\n" 872msgid "SUN4V-8001-N4.action" 873msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n" 874# 875# code: SUN4V-8001-PQ 876# keys: fault.cpu.ultraSPARC-T2plus.lfu-u 877# 878msgid "SUN4V-8001-PQ.type" 879msgstr "Fault" 880msgid "SUN4V-8001-PQ.severity" 881msgstr "Major" 882msgid "SUN4V-8001-PQ.description" 883msgstr "A CPU chip's Link Framing Unit has encountered an unrecoverable lane failure.\n Refer to %s for more information." 884msgid "SUN4V-8001-PQ.response" 885msgstr "No automated response.\n" 886msgid "SUN4V-8001-PQ.impact" 887msgstr "The system's integrity is seriously compromised.\n" 888msgid "SUN4V-8001-PQ.action" 889msgstr "Do not rely on this system for mission-critical tasks.\nSchedule a repair procedure to replace the affected resource, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n" 890# 891# code: SUN4V-8001-QC 892# keys: fault.asic.ultraSPARC-T2plus.interconnect.opu-u 893# 894msgid "SUN4V-8001-QC.type" 895msgstr "Fault" 896msgid "SUN4V-8001-QC.severity" 897msgstr "Critical" 898msgid "SUN4V-8001-QC.description" 899msgstr "The ultraSPARC-T2plus Coherency Interconnect has detected a fatal\ninternal problem.\n Refer to %s for more information." 900msgid "SUN4V-8001-QC.response" 901msgstr "No automated reponse.\n" 902msgid "SUN4V-8001-QC.impact" 903msgstr "The system's integrity is compromised.\n" 904msgid "SUN4V-8001-QC.action" 905msgstr "Schedule a repair procedure to replace the affected component, the identity\nof which can be determined by using fmdump -v -u <EVENT_ID>.\n" 906# 907# code: SUN4V-8001-R3 908# keys: fault.asic.ultraSPARC-T2plus.interconnect.opu-c 909# 910msgid "SUN4V-8001-R3.type" 911msgstr "Fault" 912msgid "SUN4V-8001-R3.severity" 913msgstr "Major" 914msgid "SUN4V-8001-R3.description" 915msgstr "The ultraSPARC-T2plus Coherency Interconnect has detected an internal problem.\n Refer to %s for more information." 916msgid "SUN4V-8001-R3.response" 917msgstr "No automated reponse.\n" 918msgid "SUN4V-8001-R3.impact" 919msgstr "The system's integrity is compromised.\n" 920msgid "SUN4V-8001-R3.action" 921msgstr "Schedule a repair procedure to replace the affected component, the identity\nof which can be determined by using fmdump -v -u <EVENT_ID>.\n" 922# 923# code: SUN4V-8001-SY 924# keys: fault.cpu.ultraSPARC-T2plus.chip 925# 926msgid "SUN4V-8001-SY.type" 927msgstr "Fault" 928msgid "SUN4V-8001-SY.severity" 929msgstr "Critical" 930msgid "SUN4V-8001-SY.description" 931msgstr "An ultraSPARC-T2plus Interconnect has detected a fatal communication\nproblem with a CPU.\n Refer to %s for more information." 932msgid "SUN4V-8001-SY.response" 933msgstr "No automated reponse.\n" 934msgid "SUN4V-8001-SY.impact" 935msgstr "The system's integrity is seriously compromised.\n" 936msgid "SUN4V-8001-SY.action" 937msgstr "Schedule a repair procedure to replace the affected component, the identity\nof which can be determined by using fmdump -v -u <EVENT_ID>.\n" 938# 939# code: SUN4V-8001-TD 940# keys: fault.asic.ultraSPARC-T2plus.interconnect.lfu-c fault.cpu.ultraSPARC-T2plus.chip 941# 942msgid "SUN4V-8001-TD.type" 943msgstr "Fault" 944msgid "SUN4V-8001-TD.severity" 945msgstr "Minor" 946msgid "SUN4V-8001-TD.description" 947msgstr "The number of CRC errors between an ultraSPARC-T2plus\nCoherency Interconnect and a CPU has exceeded acceptable levels.\n Refer to %s for more information." 948msgid "SUN4V-8001-TD.response" 949msgstr "No automated reponse.\n" 950msgid "SUN4V-8001-TD.impact" 951msgstr "The system's integrity is seriously compromised.\n" 952msgid "SUN4V-8001-TD.action" 953msgstr "Schedule a repair procedure to replace the affected component, the identity\nof which can be determined by using fmdump -v -u <EVENT_ID>.\n" 954# 955# code: SUN4V-8001-UH 956# keys: fault.asic.ultraSPARC-T2plus.interconnect.lfu-f fault.cpu.ultraSPARC-T2plus.chip 957# 958msgid "SUN4V-8001-UH.type" 959msgstr "Fault" 960msgid "SUN4V-8001-UH.severity" 961msgstr "Major" 962msgid "SUN4V-8001-UH.description" 963msgstr "An ultraSPARC-T2plus Coherency Interconnect has detected a single-lane\nfailure communicating with a CPU.\n Refer to %s for more information." 964msgid "SUN4V-8001-UH.response" 965msgstr "No automated reponse.\n" 966msgid "SUN4V-8001-UH.impact" 967msgstr "The system's performance may be impacted.\n" 968msgid "SUN4V-8001-UH.action" 969msgstr "Schedule a repair procedure to replace the affected component, the identity\nof which can be determined by using fmdump -v -u <EVENT_ID>.\n" 970# 971# code: SUN4V-8001-VA 972# keys: fault.asic.ultraSPARC-T2plus.interconnect.lfu-u fault.cpu.ultraSPARC-T2plus.chip 973# 974msgid "SUN4V-8001-VA.type" 975msgstr "Fault" 976msgid "SUN4V-8001-VA.severity" 977msgstr "Critical" 978msgid "SUN4V-8001-VA.description" 979msgstr "An ultraSPARC-T2plus Coherency Interconnect has detected a fatal\nfault commnicating with a CPU.\n Refer to %s for more information." 980msgid "SUN4V-8001-VA.response" 981msgstr "No automated reponse.\n" 982msgid "SUN4V-8001-VA.impact" 983msgstr "The system's integrity is seriously compromised.\n" 984msgid "SUN4V-8001-VA.action" 985msgstr "Schedule a repair procedure to replace the affected component, the identity\nof which can be determined by using fmdump -v -u <EVENT_ID>.\n" 986# 987# code: SUN4V-8001-WP 988# keys: fault.asic.ultraSPARC-T2plus.interconnect.lfu-u 989# 990msgid "SUN4V-8001-WP.type" 991msgstr "Fault" 992msgid "SUN4V-8001-WP.severity" 993msgstr "Critical" 994msgid "SUN4V-8001-WP.description" 995msgstr "An ultraSPARC-T2plus Coherency Interconnect has detected a fatal internal\nfault and has automatically reset.\n Refer to %s for more information." 996msgid "SUN4V-8001-WP.response" 997msgstr "No automated reponse.\n" 998msgid "SUN4V-8001-WP.impact" 999msgstr "The system's integrity is seriously compromised.\n" 1000msgid "SUN4V-8001-WP.action" 1001msgstr "Schedule a repair procedure to replace the affected component, the identity\nof which can be determined by using fmdump -v -u <EVENT_ID>.\n" 1002# 1003# code: SUN4V-8001-X5 1004# keys: fault.asic.ultraSPARC-T2plus.interconnect.gpd-u fault.cpu.ultraSPARC-T2plus.chip 1005# 1006msgid "SUN4V-8001-X5.type" 1007msgstr "Fault" 1008msgid "SUN4V-8001-X5.severity" 1009msgstr "Critical" 1010msgid "SUN4V-8001-X5.description" 1011msgstr "An ultraSPARC-T2plus Coherency Interconnect has detected a fatal communication\nfault with a CPU.\n Refer to %s for more information." 1012msgid "SUN4V-8001-X5.response" 1013msgstr "No automated reponse.\n" 1014msgid "SUN4V-8001-X5.impact" 1015msgstr "The system's performance may be compromised.\n" 1016msgid "SUN4V-8001-X5.action" 1017msgstr "Schedule a repair procedure to replace the affected component, the identity\nof which can be determined by using fmdump -v -u <EVENT_ID>.\n" 1018# 1019# code: SUN4V-8001-YS 1020# keys: fault.asic.ultraSPARC-T2plus.interconnect.gpd-c fault.cpu.ultraSPARC-T2plus.chip 1021# 1022msgid "SUN4V-8001-YS.type" 1023msgstr "Fault" 1024msgid "SUN4V-8001-YS.severity" 1025msgstr "Major" 1026msgid "SUN4V-8001-YS.description" 1027msgstr "An ultraSPARC-T2plus Coherency Interconnect has detected a fault\ncommunicating with a CPU.\n Refer to %s for more information." 1028msgid "SUN4V-8001-YS.response" 1029msgstr "No automated reponse.\n" 1030msgid "SUN4V-8001-YS.impact" 1031msgstr "The system's integrity may be seriously compromised.\n" 1032msgid "SUN4V-8001-YS.action" 1033msgstr "Schedule a repair procedure to replace the affected component, the identity\nof which can be determined by using fmdump -v -u <EVENT_ID>.\n" 1034# 1035# code: SUN4V-8002-0C 1036# keys: fault.asic.ultraSPARC-T2plus.interconnect.gpd-c 1037# 1038msgid "SUN4V-8002-0C.type" 1039msgstr "Fault" 1040msgid "SUN4V-8002-0C.severity" 1041msgstr "Major" 1042msgid "SUN4V-8002-0C.description" 1043msgstr "The ultraSPARC-T2plus Interconnect has detected a fault communicating\nwith the service processor.\n Refer to %s for more information." 1044msgid "SUN4V-8002-0C.response" 1045msgstr "No automated reponse.\n" 1046msgid "SUN4V-8002-0C.impact" 1047msgstr "The system's performance may be impacted.\n" 1048msgid "SUN4V-8002-0C.action" 1049msgstr "Schedule a repair procedure to replace the affected component, the identity\nof which can be determined by using fmdump -v -u <EVENT_ID>.\n" 1050# 1051# code: SUN4V-8002-1Q 1052# keys: fault.asic.fpga fault.asic.ultraSPARC-T2plus.interconnect.gpd-c 1053# 1054msgid "SUN4V-8002-1Q.type" 1055msgstr "Fault" 1056msgid "SUN4V-8002-1Q.severity" 1057msgstr "Major" 1058msgid "SUN4V-8002-1Q.description" 1059msgstr "ultraSPARC-T2plus Coherency Interconnect detected a fault on the LPC bus.\n Refer to %s for more information." 1060msgid "SUN4V-8002-1Q.response" 1061msgstr "No automated reponse.\n" 1062msgid "SUN4V-8002-1Q.impact" 1063msgstr "The system's performance may be impacted.\n" 1064msgid "SUN4V-8002-1Q.action" 1065msgstr "Schedule a repair procedure to replace the affected component, the identity\nof which can be determined by using fmdump -v -u <EVENT_ID>.\n" 1066# 1067# code: SUN4V-8002-24 1068# keys: fault.asic.ultraSPARC-T2plus.interconnect.asu 1069# 1070msgid "SUN4V-8002-24.type" 1071msgstr "Fault" 1072msgid "SUN4V-8002-24.severity" 1073msgstr "Critical" 1074msgid "SUN4V-8002-24.description" 1075msgstr "An ultraSPARC-T2plus Coherency Interconnect has detected a fatal fault.\n Refer to %s for more information." 1076msgid "SUN4V-8002-24.response" 1077msgstr "No automated reponse.\n" 1078msgid "SUN4V-8002-24.impact" 1079msgstr "The system's integrity is seriously compromised.\n" 1080msgid "SUN4V-8002-24.action" 1081msgstr "Schedule a repair procedure to replace the affected component, the identity\nof which can be determined by using fmdump -v -u <EVENT_ID>.\n" 1082# 1083# code: SUN4V-8002-3R 1084# keys: fault.memory.dimm-page-retires-excessive 1085# 1086msgid "SUN4V-8002-3R.type" 1087msgstr "Fault" 1088msgid "SUN4V-8002-3R.severity" 1089msgstr "Major" 1090msgid "SUN4V-8002-3R.description" 1091msgstr "The number of correctable errors associated with this memory module has exceeded acceptable levels.\n Refer to %s for more information." 1092msgid "SUN4V-8002-3R.response" 1093msgstr "Pages of memory associated with this memory module have been removed from service, up to a limit which has now been reached.\n" 1094msgid "SUN4V-8002-3R.impact" 1095msgstr "Total system memory capacity has been reduced.\n" 1096msgid "SUN4V-8002-3R.action" 1097msgstr "Schedule a repair procedure to replace the DIMM. Use fmadm faulty to identify the DIMM to replace.\n" 1098# 1099# code: SUN4V-8002-42 1100# keys: fault.memory.dimm-ue-imminent 1101# 1102msgid "SUN4V-8002-42.type" 1103msgstr "Fault" 1104msgid "SUN4V-8002-42.severity" 1105msgstr "Critical" 1106msgid "SUN4V-8002-42.description" 1107msgstr "A pattern of correctable errors has been observed suggesting the potential exists that an uncorrectable error may occur.\n Refer to %s for more information." 1108msgid "SUN4V-8002-42.response" 1109msgstr "None at this time.\n" 1110msgid "SUN4V-8002-42.impact" 1111msgstr "None at this time. However, the potential uncorrectable error warrants proactive service action to avoid any unplanned system outages.\n" 1112msgid "SUN4V-8002-42.action" 1113msgstr "Schedule a repair procedure to replace the DIMM. Use fmadm faulty to identify the DIMM to replace.\n" 1114# 1115# code: SUN4V-8002-5X 1116# keys: fault.memory.dram-ue-imminent 1117# 1118msgid "SUN4V-8002-5X.type" 1119msgstr "Fault" 1120msgid "SUN4V-8002-5X.severity" 1121msgstr "Critical" 1122msgid "SUN4V-8002-5X.description" 1123msgstr "A pattern of correctable errors has been observed suggesting the potential exists that an uncorrectable error may occur.\n Refer to %s for more information." 1124msgid "SUN4V-8002-5X.response" 1125msgstr "None at this time.\n" 1126msgid "SUN4V-8002-5X.impact" 1127msgstr "None at this time. However, the potential uncorrectable error warrants proactive service action to avoid any unplanned system outages.\n" 1128msgid "SUN4V-8002-5X.action" 1129msgstr "Schedule a repair procedure to replace the DIMM. Use fmadm faulty to identify the DIMM to replace.\n" 1130# 1131# code: SUN4V-8002-6E 1132# keys: fault.cpu.generic-sparc.strand 1133# 1134msgid "SUN4V-8002-6E.type" 1135msgstr "Fault" 1136msgid "SUN4V-8002-6E.severity" 1137msgstr "Major" 1138msgid "SUN4V-8002-6E.description" 1139msgstr "The number of correctable errors associated with this strand has exceeded acceptable levels.\n Refer to %s for more information." 1140msgid "SUN4V-8002-6E.response" 1141msgstr "The fault manager will attempt to remove the affected strand\nfrom service.\n" 1142msgid "SUN4V-8002-6E.impact" 1143msgstr "System performance may be affected. \n" 1144msgid "SUN4V-8002-6E.action" 1145msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using 'fmadm faulty'.\n" 1146# 1147# code: SUN4V-8002-7J 1148# keys: fault.cpu.generic-sparc.strand-nr 1149# 1150msgid "SUN4V-8002-7J.type" 1151msgstr "Fault" 1152msgid "SUN4V-8002-7J.severity" 1153msgstr "Major" 1154msgid "SUN4V-8002-7J.description" 1155msgstr "The number of correctable errors in internal memory associated with this strand have exceeded acceptable levels.\n Refer to %s for more information." 1156msgid "SUN4V-8002-7J.response" 1157msgstr "The system may attempt to avoid using internal memory associated with this\nstrand.\n" 1158msgid "SUN4V-8002-7J.impact" 1159msgstr "System performance may be affected. \n" 1160msgid "SUN4V-8002-7J.action" 1161msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using 'fmadm faulty'.\n" 1162# 1163# code: SUN4V-8002-8S 1164# keys: fault.cpu.generic-sparc.strand-uc 1165# 1166msgid "SUN4V-8002-8S.type" 1167msgstr "Fault" 1168msgid "SUN4V-8002-8S.severity" 1169msgstr "Critical" 1170msgid "SUN4V-8002-8S.description" 1171msgstr "This strand has encountered an uncorrectable error.\n Refer to %s for more information." 1172msgid "SUN4V-8002-8S.response" 1173msgstr "The fault manager will attempt to remove the affected strand\nfrom service.\n" 1174msgid "SUN4V-8002-8S.impact" 1175msgstr "System performance may be affected. \n" 1176msgid "SUN4V-8002-8S.action" 1177msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using 'fmadm faulty'.\n" 1178# 1179# code: SUN4V-8002-95 1180# keys: fault.cpu.generic-sparc.strand-uc-nr 1181# 1182msgid "SUN4V-8002-95.type" 1183msgstr "Fault" 1184msgid "SUN4V-8002-95.severity" 1185msgstr "Critical" 1186msgid "SUN4V-8002-95.description" 1187msgstr "Internal memory associated with this strand has encountered an uncorrectable error.\n Refer to %s for more information." 1188msgid "SUN4V-8002-95.response" 1189msgstr "The system may attempt to avoid using internal memory associated with\nthis strand.\n" 1190msgid "SUN4V-8002-95.impact" 1191msgstr "System performance may be affected. \n" 1192msgid "SUN4V-8002-95.action" 1193msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using 'fmadm faulty'.\n" 1194# 1195# code: SUN4V-8002-AP 1196# keys: fault.cpu.generic-sparc.core 1197# 1198msgid "SUN4V-8002-AP.type" 1199msgstr "Fault" 1200msgid "SUN4V-8002-AP.severity" 1201msgstr "Major" 1202msgid "SUN4V-8002-AP.description" 1203msgstr "The number of correctable errors associated with this core has exceeded acceptable levels.\n Refer to %s for more information." 1204msgid "SUN4V-8002-AP.response" 1205msgstr "The fault manager will attempt to remove all strands associated with\nthis resource from service.\n" 1206msgid "SUN4V-8002-AP.impact" 1207msgstr "System performance may be affected. \n" 1208msgid "SUN4V-8002-AP.action" 1209msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using 'fmadm faulty'.\n" 1210# 1211# code: SUN4V-8002-CA 1212# keys: fault.cpu.generic-sparc.core-nr 1213# 1214msgid "SUN4V-8002-CA.type" 1215msgstr "Fault" 1216msgid "SUN4V-8002-CA.severity" 1217msgstr "Major" 1218msgid "SUN4V-8002-CA.description" 1219msgstr "The number of correctable errors in internal memory associated with this core have exceeded acceptable levels.\n Refer to %s for more information." 1220msgid "SUN4V-8002-CA.response" 1221msgstr "The system may attempt to avoid using internal memory associated with this\ncore.\n" 1222msgid "SUN4V-8002-CA.impact" 1223msgstr "System performance may be affected. \n" 1224msgid "SUN4V-8002-CA.action" 1225msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using 'fmadm faulty'.\n" 1226# 1227# code: SUN4V-8002-DH 1228# keys: fault.cpu.generic-sparc.core-uc 1229# 1230msgid "SUN4V-8002-DH.type" 1231msgstr "Fault" 1232msgid "SUN4V-8002-DH.severity" 1233msgstr "Critical" 1234msgid "SUN4V-8002-DH.description" 1235msgstr "This core has encountered an uncorrectable error.\n Refer to %s for more information." 1236msgid "SUN4V-8002-DH.response" 1237msgstr "The fault manager will attempt to remove all strands associated with\nthis resource from service.\n" 1238msgid "SUN4V-8002-DH.impact" 1239msgstr "System performance may be affected. \n" 1240msgid "SUN4V-8002-DH.action" 1241msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using 'fmadm faulty'.\n" 1242# 1243# code: SUN4V-8002-ED 1244# keys: fault.cpu.generic-sparc.core-uc-nr 1245# 1246msgid "SUN4V-8002-ED.type" 1247msgstr "Fault" 1248msgid "SUN4V-8002-ED.severity" 1249msgstr "Critical" 1250msgid "SUN4V-8002-ED.description" 1251msgstr "An uncorrectable error has occurred in internal memory associated with this core.\n Refer to %s for more information." 1252msgid "SUN4V-8002-ED.response" 1253msgstr "The system may attempt to avoid using internal memory associated with this\ncore.\n" 1254msgid "SUN4V-8002-ED.impact" 1255msgstr "System performance may be affected. \n" 1256msgid "SUN4V-8002-ED.action" 1257msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using 'fmadm faulty'.\n" 1258# 1259# code: SUN4V-8002-FY 1260# keys: fault.cpu.generic-sparc.chip 1261# 1262msgid "SUN4V-8002-FY.type" 1263msgstr "Fault" 1264msgid "SUN4V-8002-FY.severity" 1265msgstr "Critical" 1266msgid "SUN4V-8002-FY.description" 1267msgstr "The number of chip-level correctable errors has exceeded acceptable levels.\n Refer to %s for more information." 1268msgid "SUN4V-8002-FY.response" 1269msgstr "No automated response.\n" 1270msgid "SUN4V-8002-FY.impact" 1271msgstr "System performance may be affected. \n" 1272msgid "SUN4V-8002-FY.action" 1273msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using 'fmadm faulty'.\n" 1274# 1275# code: SUN4V-8002-G3 1276# keys: fault.cpu.generic-sparc.chip-nr 1277# 1278msgid "SUN4V-8002-G3.type" 1279msgstr "Fault" 1280msgid "SUN4V-8002-G3.severity" 1281msgstr "Critical" 1282msgid "SUN4V-8002-G3.description" 1283msgstr "The number of correctable errors in internal memory associated with this chip have exceeded acceptable levels.\n Refer to %s for more information." 1284msgid "SUN4V-8002-G3.response" 1285msgstr "The system may attempt to avoid using internal memory associated with this\nchip.\n" 1286msgid "SUN4V-8002-G3.impact" 1287msgstr "System performance may be affected. \n" 1288msgid "SUN4V-8002-G3.action" 1289msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using 'fmadm faulty'.\n" 1290# 1291# code: SUN4V-8002-HR 1292# keys: fault.cpu.generic-sparc.chip-uc 1293# 1294msgid "SUN4V-8002-HR.type" 1295msgstr "Fault" 1296msgid "SUN4V-8002-HR.severity" 1297msgstr "Critical" 1298msgid "SUN4V-8002-HR.description" 1299msgstr "This chip has encountered a chip-level uncorrectable error.\n Refer to %s for more information." 1300msgid "SUN4V-8002-HR.response" 1301msgstr "The system will attempt to retire all strands in this chip.\n" 1302msgid "SUN4V-8002-HR.impact" 1303msgstr "System performance may be affected. \n" 1304msgid "SUN4V-8002-HR.action" 1305msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using 'fmadm faulty'.\n" 1306# 1307# code: SUN4V-8002-J4 1308# keys: fault.cpu.generic-sparc.chip-uc-nr 1309# 1310msgid "SUN4V-8002-J4.type" 1311msgstr "Fault" 1312msgid "SUN4V-8002-J4.severity" 1313msgstr "Critical" 1314msgid "SUN4V-8002-J4.description" 1315msgstr "Internal memory associated with this chip has encountered an uncorrectable\nerror.\n Refer to %s for more information." 1316msgid "SUN4V-8002-J4.response" 1317msgstr "The system may attempt to avoid using internal memory associated with this\nchip.\n" 1318msgid "SUN4V-8002-J4.impact" 1319msgstr "System performance may be affected. \n" 1320msgid "SUN4V-8002-J4.action" 1321msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using 'fmadm faulty'.\n" 1322# 1323# code: SUN4V-8002-KQ 1324# keys: fault.cpu.generic-sparc.c2c 1325# 1326msgid "SUN4V-8002-KQ.type" 1327msgstr "Fault" 1328msgid "SUN4V-8002-KQ.severity" 1329msgstr "Major" 1330msgid "SUN4V-8002-KQ.description" 1331msgstr "The number of chip-to-chip recoverable errors has exceeded acceptable levels.\n Refer to %s for more information." 1332msgid "SUN4V-8002-KQ.response" 1333msgstr "No automated response.\n" 1334msgid "SUN4V-8002-KQ.impact" 1335msgstr "System performance may be affected.\n" 1336msgid "SUN4V-8002-KQ.action" 1337msgstr "Schedule a repair procedure to replace the affected resource(s), the identity of which can be determined using 'fmadm faulty'.\n" 1338# 1339# code: SUN4V-8002-LC 1340# keys: fault.cpu.generic-sparc.c2c-failover 1341# 1342msgid "SUN4V-8002-LC.type" 1343msgstr "Fault" 1344msgid "SUN4V-8002-LC.severity" 1345msgstr "Major" 1346msgid "SUN4V-8002-LC.description" 1347msgstr "A CRC error has occurred in the interconnect between two CPU chips.\nWhile no data has been lost, a lane failover has taken place.\n Refer to %s for more information." 1348msgid "SUN4V-8002-LC.response" 1349msgstr "The hardware has automatically reconfigured the link to isolate the\nfailing lane, and successful retransmission of the data has occurred.\n" 1350msgid "SUN4V-8002-LC.impact" 1351msgstr "The system's capacity to correct transmission errors between CPU chips\nhas been reduced.\n" 1352msgid "SUN4V-8002-LC.action" 1353msgstr "Schedule a repair procedure to replace the affected resource(s), the identity of which can be determined using 'fmadm faulty'.\n" 1354# 1355# code: SUN4V-8002-MJ 1356# keys: fault.cpu.generic-sparc.c2c-uc 1357# 1358msgid "SUN4V-8002-MJ.type" 1359msgstr "Fault" 1360msgid "SUN4V-8002-MJ.severity" 1361msgstr "Critical" 1362msgid "SUN4V-8002-MJ.description" 1363msgstr "A chip-to-chip unrecoverable CRC error has occurred.\n Refer to %s for more information." 1364msgid "SUN4V-8002-MJ.response" 1365msgstr "The system has halted in order to prevent corruption of data.\nNo further automated response.\n" 1366msgid "SUN4V-8002-MJ.impact" 1367msgstr "The system halts and must be restarted. The integrity of this system has\nbeen compromised.\n" 1368msgid "SUN4V-8002-MJ.action" 1369msgstr "Schedule a repair procedure to replace the affected resource(s), the identity of which can be determined using 'fmadm faulty'.\n" 1370# 1371# code: SUN4V-8002-NE 1372# keys: fault.memory.memlink 1373# 1374msgid "SUN4V-8002-NE.type" 1375msgstr "Fault" 1376msgid "SUN4V-8002-NE.severity" 1377msgstr "Major" 1378msgid "SUN4V-8002-NE.description" 1379msgstr "Recoverable CRC errors have occurred in the interconnect between a\nmemory buffer and its memory controller. No data has been lost;\nhowever, the number of CRC errors associated with this memory buffer-controller\npair has exceeded acceptable levels.\n Refer to %s for more information." 1380msgid "SUN4V-8002-NE.response" 1381msgstr "The system has recovered from the CRC errors.\n" 1382msgid "SUN4V-8002-NE.impact" 1383msgstr "System performance may be impacted by a slight reduction in effective\nmemory bandwidth.\n" 1384msgid "SUN4V-8002-NE.action" 1385msgstr "At a convenient time, schedule a repair procedure to replace the affected resource(s), the identity of which can be determined using 'fmadm faulty'.\n" 1386# 1387# code: SUN4V-8002-PX 1388# keys: fault.memory.memlink-failover 1389# 1390msgid "SUN4V-8002-PX.type" 1391msgstr "Fault" 1392msgid "SUN4V-8002-PX.severity" 1393msgstr "Major" 1394msgid "SUN4V-8002-PX.description" 1395msgstr "A CRC error has occurred in the interconnect between a memory buffer and\nits memory controller. While no data has been lost, a lane failover\nhas taken place.\n Refer to %s for more information." 1396msgid "SUN4V-8002-PX.response" 1397msgstr "The hardware has automatically reconfigured the link to isolate the\nfailing lane, and successful retransmission of the data has occurred.\n" 1398msgid "SUN4V-8002-PX.impact" 1399msgstr "The system's capacity to correct transmission errors between the memory\nDIMM and its memory controller has been reduced.\n" 1400msgid "SUN4V-8002-PX.action" 1401msgstr "At your earliest convenience, schedule a repair procedure to replace the\naffected resource(s), the identity of which can be determined using\n'fmadm faulty'.\n" 1402# 1403# code: SUN4V-8002-Q2 1404# keys: fault.memory.memlink-uc 1405# 1406msgid "SUN4V-8002-Q2.type" 1407msgstr "Fault" 1408msgid "SUN4V-8002-Q2.severity" 1409msgstr "Critical" 1410msgid "SUN4V-8002-Q2.description" 1411msgstr "A problem was detected in the interconnect between a memory buffer\nand its memory controller.\n Refer to %s for more information." 1412msgid "SUN4V-8002-Q2.response" 1413msgstr "The system crashed to prevent data corruption. Memory in the affected\npartition may have been deconfigured. (Consult system-specific\ndocumentation to find out how to determine if memory has been\ndeconfigured.)\n" 1414msgid "SUN4V-8002-Q2.impact" 1415msgstr "If memory has been deconfigured, system performance may be impacted. \n" 1416msgid "SUN4V-8002-Q2.action" 1417msgstr "Schedule a repair procedure to replace the appropriate part(s), the identity of which can be determined using 'fmadm faulty'.\n" 1418# 1419# code: SUN4V-8002-RA 1420# keys: defect.fw.generic-sparc.addr-oob 1421# 1422msgid "SUN4V-8002-RA.type" 1423msgstr "Fault" 1424msgid "SUN4V-8002-RA.severity" 1425msgstr "Critical" 1426msgid "SUN4V-8002-RA.description" 1427msgstr "An address-out-of-bounds error has occurred.\n Refer to %s for more information." 1428msgid "SUN4V-8002-RA.response" 1429msgstr "No automated response.\n" 1430msgid "SUN4V-8002-RA.impact" 1431msgstr "The system may have taken a fatal reset.\n" 1432msgid "SUN4V-8002-RA.action" 1433msgstr "Call your service provider to determine if your system requires a firmware upgrade.\n" 1434# 1435# code: SUN4V-8002-SP 1436# keys: defect.fw.generic-sparc.erpt-gen 1437# 1438msgid "SUN4V-8002-SP.type" 1439msgstr "Fault" 1440msgid "SUN4V-8002-SP.severity" 1441msgstr "Major" 1442msgid "SUN4V-8002-SP.description" 1443msgstr "The error report generator has received input data that is inconsistent or\nimproperly formatted.\n Refer to %s for more information." 1444msgid "SUN4V-8002-SP.response" 1445msgstr "No automated response.\n" 1446msgid "SUN4V-8002-SP.impact" 1447msgstr "This error does not affect system operation. The error which\ncould not be reported may have more serious impact which cannot be determined.\n" 1448msgid "SUN4V-8002-SP.action" 1449msgstr "Call your service provider to determine if your system requires a firmware\nupgrade. Please retain the error log file.\n" 1450# 1451# code: SUN4V-8002-T5 1452# keys: fault.cpu.generic-sparc.bootbus 1453# 1454msgid "SUN4V-8002-T5.type" 1455msgstr "Fault" 1456msgid "SUN4V-8002-T5.severity" 1457msgstr "Critical" 1458msgid "SUN4V-8002-T5.description" 1459msgstr "A system boot bus error has occurred.\n Refer to %s for more information." 1460msgid "SUN4V-8002-T5.response" 1461msgstr "No automated response.\n" 1462msgid "SUN4V-8002-T5.impact" 1463msgstr "The system's integrity is seriously compromised. Processor chip(s)\nmay be unavailable.\n" 1464msgid "SUN4V-8002-T5.action" 1465msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using 'fmadm faulty'.\n" 1466