1# 2# Copyright 2006 Sun Microsystems, Inc. All rights reserved. 3# Use is subject to license terms. 4# 5# CDDL HEADER START 6# 7# The contents of this file are subject to the terms of the 8# Common Development and Distribution License (the "License"). 9# You may not use this file except in compliance with the License. 10# 11# You can obtain a copy of the license at usr/src/OPENSOLARIS.LICENSE 12# or http://www.opensolaris.org/os/licensing. 13# See the License for the specific language governing permissions 14# and limitations under the License. 15# 16# When distributing Covered Code, include this CDDL HEADER in each 17# file and include the License file at usr/src/OPENSOLARIS.LICENSE. 18# If applicable, add the following below this CDDL HEADER, with the 19# fields enclosed by brackets "[]" replaced with your own identifying 20# information: Portions Copyright [yyyy] [name of copyright owner] 21# 22# CDDL HEADER END 23# 24#ident "%Z%%M% %I% %E% SMI" 25# 26# DO NOT EDIT -- this file is generated by the Event Registry. 27# 28# 29# code: SUN4U-8000-1A 30# keys: fault.memory.page 31# 32msgid "SUN4U-8000-1A.type" 33msgstr "Fault" 34msgid "SUN4U-8000-1A.severity" 35msgstr "Minor" 36msgid "SUN4U-8000-1A.description" 37msgstr "The number of errors associated with this memory module continues to exceed acceptable levels. Refer to %s for more information." 38msgid "SUN4U-8000-1A.response" 39msgstr "An attempt will be made to remove this memory page from service." 40msgid "SUN4U-8000-1A.impact" 41msgstr "The performance of the system may be minimally impacted as a result of removing the memory page from operation." 42msgid "SUN4U-8000-1A.action" 43msgstr "No repair action is recommended at this time." 44# 45# code: SUN4U-8000-2S 46# keys: fault.memory.dimm 47# 48msgid "SUN4U-8000-2S.type" 49msgstr "Fault" 50msgid "SUN4U-8000-2S.severity" 51msgstr "Major" 52msgid "SUN4U-8000-2S.description" 53msgstr "The number of errors associated with this memory module has exceeded acceptable levels. Refer to %s for more information." 54msgid "SUN4U-8000-2S.response" 55msgstr "Pages of memory associated with this memory module are being removed from service as errors are reported." 56msgid "SUN4U-8000-2S.impact" 57msgstr "Total system memory capacity will be reduced as pages are retired." 58msgid "SUN4U-8000-2S.action" 59msgstr "Schedule a repair procedure to replace the affected memory module. Use fmdump -v -u <EVENT_ID> to identify the module." 60# 61# code: SUN4U-8000-35 62# keys: fault.memory.bank 63# 64msgid "SUN4U-8000-35.type" 65msgstr "Fault" 66msgid "SUN4U-8000-35.severity" 67msgstr "Critical" 68msgid "SUN4U-8000-35.description" 69msgstr "The number of errors associated with this memory module has exceeded acceptable levels. Refer to %s for more information." 70msgid "SUN4U-8000-35.response" 71msgstr "Pages of memory associated with this memory module are being removed from service as errors are reported." 72msgid "SUN4U-8000-35.impact" 73msgstr "Total system memory capacity will be reduced as pages are retired." 74msgid "SUN4U-8000-35.action" 75msgstr "Schedule a repair procedure to replace the affected memory module. Use fmdump -v -u <EVENT_ID> to identify the module." 76# 77# code: SUN4U-8000-4Y 78# keys: fault.cpu.ultraSPARC-III.dcache 79# 80msgid "SUN4U-8000-4Y.type" 81msgstr "Fault" 82msgid "SUN4U-8000-4Y.severity" 83msgstr "Major" 84msgid "SUN4U-8000-4Y.description" 85msgstr "The number of errors associated with a CPU has exceeded acceptable levels. Refer to %s for more information." 86msgid "SUN4U-8000-4Y.response" 87msgstr "The fault manager will attempt to remove the affected CPU from service." 88msgid "SUN4U-8000-4Y.impact" 89msgstr "System performance may be affected." 90msgid "SUN4U-8000-4Y.action" 91msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>." 92# 93# code: SUN4U-8000-53 94# keys: fault.cpu.ultraSPARC-III.icache 95# 96msgid "SUN4U-8000-53.type" 97msgstr "Fault" 98msgid "SUN4U-8000-53.severity" 99msgstr "Major" 100msgid "SUN4U-8000-53.description" 101msgstr "The number of errors associated with a CPU has exceeded acceptable levels. Refer to %s for more information." 102msgid "SUN4U-8000-53.response" 103msgstr "The fault manager will attempt to remove the affected CPU from service." 104msgid "SUN4U-8000-53.impact" 105msgstr "System performance may be affected." 106msgid "SUN4U-8000-53.action" 107msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>." 108# 109# code: SUN4U-8000-6H 110# keys: fault.cpu.ultraSPARC-III.l2cachedata 111# 112msgid "SUN4U-8000-6H.type" 113msgstr "Fault" 114msgid "SUN4U-8000-6H.severity" 115msgstr "Major" 116msgid "SUN4U-8000-6H.description" 117msgstr "The number of errors associated with this CPU has exceeded acceptable levels. Refer to %s for more information." 118msgid "SUN4U-8000-6H.response" 119msgstr "The fault manager will attempt to remove the affected CPU from service." 120msgid "SUN4U-8000-6H.impact" 121msgstr "System performance may be affected." 122msgid "SUN4U-8000-6H.action" 123msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>." 124# 125# code: SUN4U-8000-7D 126# keys: fault.cpu.ultraSPARC-III.l2cachetag 127# 128msgid "SUN4U-8000-7D.type" 129msgstr "Fault" 130msgid "SUN4U-8000-7D.severity" 131msgstr "Major" 132msgid "SUN4U-8000-7D.description" 133msgstr "The number of errors associated with this CPU has exceeded acceptable levels. Refer to %s for more information." 134msgid "SUN4U-8000-7D.response" 135msgstr "The fault manager will attempt to remove the affected CPU from service." 136msgid "SUN4U-8000-7D.impact" 137msgstr "System performance may be affected." 138msgid "SUN4U-8000-7D.action" 139msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>." 140# 141# code: SUN4U-8000-84 142# keys: fault.cpu.ultraSPARC-IIIi.dcache 143# 144msgid "SUN4U-8000-84.type" 145msgstr "Fault" 146msgid "SUN4U-8000-84.severity" 147msgstr "Major" 148msgid "SUN4U-8000-84.description" 149msgstr "The number of errors associated with this CPU has exceeded acceptable levels. Refer to %s for more information." 150msgid "SUN4U-8000-84.response" 151msgstr "The fault manager will attempt to remove the affected CPU from service." 152msgid "SUN4U-8000-84.impact" 153msgstr "System performance system may be affected." 154msgid "SUN4U-8000-84.action" 155msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>." 156# 157# code: SUN4U-8000-9R 158# keys: fault.cpu.ultraSPARC-IIIi.icache 159# 160msgid "SUN4U-8000-9R.type" 161msgstr "Fault" 162msgid "SUN4U-8000-9R.severity" 163msgstr "Major" 164msgid "SUN4U-8000-9R.description" 165msgstr "The number of errors associated with this CPU has exceeded acceptable levels. Refer to %s for more information." 166msgid "SUN4U-8000-9R.response" 167msgstr "The fault manager will attempt to remove the affected CPU from service." 168msgid "SUN4U-8000-9R.impact" 169msgstr "System performance may be affected." 170msgid "SUN4U-8000-9R.action" 171msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>." 172# 173# code: SUN4U-8000-AC 174# keys: fault.cpu.ultraSPARC-IIIi.l2cachedata 175# 176msgid "SUN4U-8000-AC.type" 177msgstr "Fault" 178msgid "SUN4U-8000-AC.severity" 179msgstr "Major" 180msgid "SUN4U-8000-AC.description" 181msgstr "The number of errors associated with this CPU has exceeded acceptable levels. Refer to %s for more information." 182msgid "SUN4U-8000-AC.response" 183msgstr "The fault manager will attempt to remove the affected CPU from service." 184msgid "SUN4U-8000-AC.impact" 185msgstr "System performance may be affected." 186msgid "SUN4U-8000-AC.action" 187msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>." 188# 189# code: SUN4U-8000-CQ 190# keys: fault.cpu.ultraSPARC-IIIi.l2cachetag 191# 192msgid "SUN4U-8000-CQ.type" 193msgstr "Fault" 194msgid "SUN4U-8000-CQ.severity" 195msgstr "Major" 196msgid "SUN4U-8000-CQ.description" 197msgstr "The number of errors associated with this CPU has exceeded acceptable levels. Refer to %s for more information." 198msgid "SUN4U-8000-CQ.response" 199msgstr "The fault manager will attempt to remove the affected CPU from service." 200msgid "SUN4U-8000-CQ.impact" 201msgstr "System performance may be affected." 202msgid "SUN4U-8000-CQ.action" 203msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>." 204# 205# code: SUN4U-8000-DE 206# keys: fault.cpu.ultraSPARC-IIIplus.dcache 207# 208msgid "SUN4U-8000-DE.type" 209msgstr "Fault" 210msgid "SUN4U-8000-DE.severity" 211msgstr "Major" 212msgid "SUN4U-8000-DE.description" 213msgstr "The number of errors associated with this CPU has exceeded acceptable levels. Refer to %s for more information." 214msgid "SUN4U-8000-DE.response" 215msgstr "The fault manager will attempt to remove the affected CPU from service." 216msgid "SUN4U-8000-DE.impact" 217msgstr "System performance may be affected." 218msgid "SUN4U-8000-DE.action" 219msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>." 220# 221# code: SUN4U-8000-EJ 222# keys: fault.cpu.ultraSPARC-IIIplus.icache 223# 224msgid "SUN4U-8000-EJ.type" 225msgstr "Fault" 226msgid "SUN4U-8000-EJ.severity" 227msgstr "Major" 228msgid "SUN4U-8000-EJ.description" 229msgstr "The number of errors associated with this CPU has exceeded acceptable levels. Refer to %s for more information." 230msgid "SUN4U-8000-EJ.response" 231msgstr "The fault manager will attempt to remove the affected CPU from service." 232msgid "SUN4U-8000-EJ.impact" 233msgstr "System performance may be affected." 234msgid "SUN4U-8000-EJ.action" 235msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>." 236# 237# code: SUN4U-8000-F2 238# keys: fault.cpu.ultraSPARC-IIIplus.l2cachedata 239# 240msgid "SUN4U-8000-F2.type" 241msgstr "Fault" 242msgid "SUN4U-8000-F2.severity" 243msgstr "Major" 244msgid "SUN4U-8000-F2.description" 245msgstr "The number of errors associated with this CPU has exceeded acceptable levels. Refer to %s for more information." 246msgid "SUN4U-8000-F2.response" 247msgstr "The fault manager will attempt to remove the affected CPU from service." 248msgid "SUN4U-8000-F2.impact" 249msgstr "System performance may be affected." 250msgid "SUN4U-8000-F2.action" 251msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>." 252# 253# code: SUN4U-8000-GX 254# keys: fault.cpu.ultraSPARC-IIIplus.l2cachetag 255# 256msgid "SUN4U-8000-GX.type" 257msgstr "Fault" 258msgid "SUN4U-8000-GX.severity" 259msgstr "Major" 260msgid "SUN4U-8000-GX.description" 261msgstr "The number of errors associated with this CPU has exceeded acceptable levels. Refer to %s for more information." 262msgid "SUN4U-8000-GX.response" 263msgstr "An attempt will be made to remove the affected CPU from service." 264msgid "SUN4U-8000-GX.impact" 265msgstr "System performance may be affected." 266msgid "SUN4U-8000-GX.action" 267msgstr "Schedule a repair procedure to replace the affected CPU. Use fmdump -v -u <EVENT_ID> to identify the CPU." 268# 269# code: SUN4U-8000-H5 270# keys: fault.cpu.ultraSPARC-IV.dcache 271# 272msgid "SUN4U-8000-H5.type" 273msgstr "Fault" 274msgid "SUN4U-8000-H5.severity" 275msgstr "Major" 276msgid "SUN4U-8000-H5.description" 277msgstr "The number of errors associated with this CPU has exceeded acceptable levels. Refer to %s for more information." 278msgid "SUN4U-8000-H5.response" 279msgstr "The fault manager will attempt to remove the affected CPU from service." 280msgid "SUN4U-8000-H5.impact" 281msgstr "System performance may be affected." 282msgid "SUN4U-8000-H5.action" 283msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>." 284# 285# code: SUN4U-8000-JS 286# keys: fault.cpu.ultraSPARC-IV.icache 287# 288msgid "SUN4U-8000-JS.type" 289msgstr "Fault" 290msgid "SUN4U-8000-JS.severity" 291msgstr "Major" 292msgid "SUN4U-8000-JS.description" 293msgstr "The number of errors associated with this CPU has exceeded acceptable levels. Refer to %s for more information." 294msgid "SUN4U-8000-JS.response" 295msgstr "The fault manager will attempt to remove the affected CPU from service." 296msgid "SUN4U-8000-JS.impact" 297msgstr "System performance may be affected." 298msgid "SUN4U-8000-JS.action" 299msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>." 300# 301# code: SUN4U-8000-KA 302# keys: fault.cpu.ultraSPARC-IV.l2cachedata 303# 304msgid "SUN4U-8000-KA.type" 305msgstr "Fault" 306msgid "SUN4U-8000-KA.severity" 307msgstr "Major" 308msgid "SUN4U-8000-KA.description" 309msgstr "The number of errors associated with this CPU has exceeded acceptable levels. Refer to %s for more information." 310msgid "SUN4U-8000-KA.response" 311msgstr "The fault manager will attempt to remove the affected CPU from service." 312msgid "SUN4U-8000-KA.impact" 313msgstr "System performance may be affected." 314msgid "SUN4U-8000-KA.action" 315msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>." 316# 317# code: SUN4U-8000-LP 318# keys: fault.cpu.ultraSPARC-IV.l2cachetag 319# 320msgid "SUN4U-8000-LP.type" 321msgstr "Fault" 322msgid "SUN4U-8000-LP.severity" 323msgstr "Major" 324msgid "SUN4U-8000-LP.description" 325msgstr "The number of errors associated with this CPU has exceeded acceptable levels. Refer to %s for more information." 326msgid "SUN4U-8000-LP.response" 327msgstr "The fault manager will attempt to remove the affected CPU from service." 328msgid "SUN4U-8000-LP.impact" 329msgstr "System performance may be affected." 330msgid "SUN4U-8000-LP.action" 331msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>." 332# 333# code: SUN4U-8000-MD 334# keys: fault.cpu.ultraSPARC-III.fpu 335# 336msgid "SUN4U-8000-MD.type" 337msgstr "Fault" 338msgid "SUN4U-8000-MD.severity" 339msgstr "Major" 340msgid "SUN4U-8000-MD.description" 341msgstr "A fault has been detected in the FPU of this CPU. Refer to %s for more information." 342msgid "SUN4U-8000-MD.response" 343msgstr "The fault manager will attempt to remove the affected CPU from service." 344msgid "SUN4U-8000-MD.impact" 345msgstr "System performance may be affected." 346msgid "SUN4U-8000-MD.action" 347msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>." 348# 349# code: SUN4U-8000-NH 350# keys: fault.cpu.ultraSPARC-IIIi.fpu 351# 352msgid "SUN4U-8000-NH.type" 353msgstr "Fault" 354msgid "SUN4U-8000-NH.severity" 355msgstr "Major" 356msgid "SUN4U-8000-NH.description" 357msgstr "A fault has been detected in the FPU of this CPU. Refer to %s for more information." 358msgid "SUN4U-8000-NH.response" 359msgstr "The fault manager will attempt to remove the affected CPU from service." 360msgid "SUN4U-8000-NH.impact" 361msgstr "System performance may be affected." 362msgid "SUN4U-8000-NH.action" 363msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>." 364# 365# code: SUN4U-8000-P3 366# keys: fault.cpu.ultraSPARC-IIIplus.fpu 367# 368msgid "SUN4U-8000-P3.type" 369msgstr "Fault" 370msgid "SUN4U-8000-P3.severity" 371msgstr "Major" 372msgid "SUN4U-8000-P3.description" 373msgstr "A fault has been detected in the FPU of this CPU. Refer to %s for more information." 374msgid "SUN4U-8000-P3.response" 375msgstr "The fault manager will attempt to remove the affected CPU from service." 376msgid "SUN4U-8000-P3.impact" 377msgstr "System performance may be affected." 378msgid "SUN4U-8000-P3.action" 379msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>." 380# 381# code: SUN4U-8000-QY 382# keys: fault.cpu.ultraSPARC-IV.fpu 383# 384msgid "SUN4U-8000-QY.type" 385msgstr "Fault" 386msgid "SUN4U-8000-QY.severity" 387msgstr "Major" 388msgid "SUN4U-8000-QY.description" 389msgstr "A fault has been detected in the FPU of this CPU. Refer to %s for more information." 390msgid "SUN4U-8000-QY.response" 391msgstr "The fault manager will attempt to remove the affected CPU from service." 392msgid "SUN4U-8000-QY.impact" 393msgstr "System performance may be affected." 394msgid "SUN4U-8000-QY.action" 395msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>." 396# 397# code: SUN4U-8000-RQ 398# keys: fault.cpu.ultraSPARC-IVplus.fpu 399# 400msgid "SUN4U-8000-RQ.type" 401msgstr "Fault" 402msgid "SUN4U-8000-RQ.severity" 403msgstr "Major" 404msgid "SUN4U-8000-RQ.description" 405msgstr "A fault has been detected in the FPU of this CPU. Refer to %s for more information." 406msgid "SUN4U-8000-RQ.response" 407msgstr "The fault manager will attempt to remove the affected CPU from service." 408msgid "SUN4U-8000-RQ.impact" 409msgstr "System performance may be affected." 410msgid "SUN4U-8000-RQ.action" 411msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>." 412# 413# code: SUN4U-8000-SC 414# keys: fault.cpu.ultraSPARC-IVplus.dcache 415# 416msgid "SUN4U-8000-SC.type" 417msgstr "Fault" 418msgid "SUN4U-8000-SC.severity" 419msgstr "Major" 420msgid "SUN4U-8000-SC.description" 421msgstr "The number of errors associated with this CPU has exceeded acceptable levels. Refer to %s for more information." 422msgid "SUN4U-8000-SC.response" 423msgstr "The fault manager will attempt to remove the affected CPU from service." 424msgid "SUN4U-8000-SC.impact" 425msgstr "System performance may be affected." 426msgid "SUN4U-8000-SC.action" 427msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>." 428# 429# code: SUN4U-8000-TR 430# keys: fault.cpu.ultraSPARC-IVplus.icache 431# 432msgid "SUN4U-8000-TR.type" 433msgstr "Fault" 434msgid "SUN4U-8000-TR.severity" 435msgstr "Major" 436msgid "SUN4U-8000-TR.description" 437msgstr "The number of errors associated with this CPU has exceeded acceptable levels. Refer to %s for more information." 438msgid "SUN4U-8000-TR.response" 439msgstr "The fault manager will attempt to remove the affected CPU from service." 440msgid "SUN4U-8000-TR.impact" 441msgstr "System performance may be affected." 442msgid "SUN4U-8000-TR.action" 443msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>." 444# 445# code: SUN4U-8000-U4 446# keys: fault.cpu.ultraSPARC-IVplus.pcache 447# 448msgid "SUN4U-8000-U4.type" 449msgstr "Fault" 450msgid "SUN4U-8000-U4.severity" 451msgstr "Major" 452msgid "SUN4U-8000-U4.description" 453msgstr "The number of errors associated with this CPU has exceeded acceptable levels. Refer to %s for more information." 454msgid "SUN4U-8000-U4.response" 455msgstr "The fault manager will attempt to remove the affected CPU from service." 456msgid "SUN4U-8000-U4.impact" 457msgstr "System performance may be affected." 458msgid "SUN4U-8000-U4.action" 459msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>." 460# 461# code: SUN4U-8000-VX 462# keys: fault.cpu.ultraSPARC-IVplus.dtlb 463# 464msgid "SUN4U-8000-VX.type" 465msgstr "Fault" 466msgid "SUN4U-8000-VX.severity" 467msgstr "Major" 468msgid "SUN4U-8000-VX.description" 469msgstr "The number of errors associated with this CPU has exceeded acceptable levels. Refer to %s for more information." 470msgid "SUN4U-8000-VX.response" 471msgstr "The fault manager will attempt to remove the affected CPU from service." 472msgid "SUN4U-8000-VX.impact" 473msgstr "System performance may be affected." 474msgid "SUN4U-8000-VX.action" 475msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>." 476# 477# code: SUN4U-8000-W2 478# keys: fault.cpu.ultraSPARC-IVplus.itlb 479# 480msgid "SUN4U-8000-W2.type" 481msgstr "Fault" 482msgid "SUN4U-8000-W2.severity" 483msgstr "Major" 484msgid "SUN4U-8000-W2.description" 485msgstr "The number of errors associated with this CPU has exceeded acceptable levels. Refer to %s for more information." 486msgid "SUN4U-8000-W2.response" 487msgstr "The fault manager will attempt to remove the affected CPU from service." 488msgid "SUN4U-8000-W2.impact" 489msgstr "System performance may be affected." 490msgid "SUN4U-8000-W2.action" 491msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>." 492# 493# code: SUN4U-8000-XJ 494# keys: fault.cpu.ultraSPARC-IVplus.l2cachedata 495# 496msgid "SUN4U-8000-XJ.type" 497msgstr "Fault" 498msgid "SUN4U-8000-XJ.severity" 499msgstr "Major" 500msgid "SUN4U-8000-XJ.description" 501msgstr "The number of errors associated with this CPU has exceeded acceptable levels. Refer to %s for more information." 502msgid "SUN4U-8000-XJ.response" 503msgstr "The fault manager will attempt to remove the affected CPU from service." 504msgid "SUN4U-8000-XJ.impact" 505msgstr "System performance may be affected." 506msgid "SUN4U-8000-XJ.action" 507msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>." 508# 509# code: SUN4U-8000-YE 510# keys: fault.cpu.ultraSPARC-IVplus.l2cachetag 511# 512msgid "SUN4U-8000-YE.type" 513msgstr "Fault" 514msgid "SUN4U-8000-YE.severity" 515msgstr "Major" 516msgid "SUN4U-8000-YE.description" 517msgstr "The number of errors associated with this CPU has exceeded acceptable levels. Refer to %s for more information." 518msgid "SUN4U-8000-YE.response" 519msgstr "The fault manager will attempt to remove the affected CPU from service." 520msgid "SUN4U-8000-YE.impact" 521msgstr "System performance may be affected." 522msgid "SUN4U-8000-YE.action" 523msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>." 524# 525# code: SUN4U-8001-0J 526# keys: fault.cpu.ultraSPARC-IVplus.l3cachedata 527# 528msgid "SUN4U-8001-0J.type" 529msgstr "Fault" 530msgid "SUN4U-8001-0J.severity" 531msgstr "Major" 532msgid "SUN4U-8001-0J.description" 533msgstr "The number of errors associated with this CPU has exceeded acceptable levels. Refer to %s for more information." 534msgid "SUN4U-8001-0J.response" 535msgstr "The fault manager will attempt to remove the affected CPU from service." 536msgid "SUN4U-8001-0J.impact" 537msgstr "System performance may be affected." 538msgid "SUN4U-8001-0J.action" 539msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>." 540# 541# code: SUN4U-8001-1E 542# keys: fault.cpu.ultraSPARC-IVplus.l3cachetag 543# 544msgid "SUN4U-8001-1E.type" 545msgstr "Fault" 546msgid "SUN4U-8001-1E.severity" 547msgstr "Major" 548msgid "SUN4U-8001-1E.description" 549msgstr "The number of errors associated with this CPU has exceeded acceptable levels. Refer to %s for more information." 550msgid "SUN4U-8001-1E.response" 551msgstr "The fault manager will attempt to remove the affected CPU from service." 552msgid "SUN4U-8001-1E.impact" 553msgstr "System performance may be affected." 554msgid "SUN4U-8001-1E.action" 555msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>." 556# 557# code: SUN4U-8001-2X 558# keys: defect.ultraSPARC-II.memory.nodiag 559# 560msgid "SUN4U-8001-2X.type" 561msgstr "Defect" 562msgid "SUN4U-8001-2X.severity" 563msgstr "Minor" 564msgid "SUN4U-8001-2X.description" 565msgstr "The Solaris Fault Manager received an event from the IO subsystem for which automated diagnosis software is currently unavailable. Refer to %s for more information." 566msgid "SUN4U-8001-2X.response" 567msgstr "The error information has been saved for examination by Sun." 568msgid "SUN4U-8001-2X.impact" 569msgstr "The error log will need to be manually examined using fmdump(1M) in order to determine if any human response is required." 570msgid "SUN4U-8001-2X.action" 571msgstr "Use fmdump -ev -u <EVENT-ID> to view and record the undiagnosed errors." 572# 573# code: SUN4U-8001-32 574# keys: fault.memory.datapath 575# 576msgid "SUN4U-8001-32.type" 577msgstr "Fault" 578msgid "SUN4U-8001-32.severity" 579msgstr "Major" 580msgid "SUN4U-8001-32.description" 581msgstr "Errors have been detected on multiple memory modules, suggesting that a problem exists somewhere else in the system. Refer to %s for more information." 582msgid "SUN4U-8001-32.response" 583msgstr "Error reports from the affected components will be logged for examination by Sun." 584msgid "SUN4U-8001-32.impact" 585msgstr "System performance and stability may be affected." 586msgid "SUN4U-8001-32.action" 587msgstr "Contact your service provider for further diagnosis." 588# 589# code: SUN4U-8001-4R 590# keys: fault.io.datapath 591# 592msgid "SUN4U-8001-4R.type" 593msgstr "Fault" 594msgid "SUN4U-8001-4R.severity" 595msgstr "Critical" 596msgid "SUN4U-8001-4R.description" 597msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." 598msgid "SUN4U-8001-4R.response" 599msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 600msgid "SUN4U-8001-4R.impact" 601msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 602msgid "SUN4U-8001-4R.action" 603msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" 604# 605# code: SUN4U-8001-54 606# keys: defect.io.pci.driver fault.io.datapath 607# 608msgid "SUN4U-8001-54.type" 609msgstr "Fault" 610msgid "SUN4U-8001-54.severity" 611msgstr "Critical" 612msgid "SUN4U-8001-54.description" 613msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." 614msgid "SUN4U-8001-54.response" 615msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 616msgid "SUN4U-8001-54.impact" 617msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 618msgid "SUN4U-8001-54.action" 619msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" 620# 621# code: SUN4U-8001-6Q 622# keys: fault.io.datapath fault.io.pci.bus 623# 624msgid "SUN4U-8001-6Q.type" 625msgstr "Fault" 626msgid "SUN4U-8001-6Q.severity" 627msgstr "Critical" 628msgid "SUN4U-8001-6Q.description" 629msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." 630msgid "SUN4U-8001-6Q.response" 631msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 632msgid "SUN4U-8001-6Q.impact" 633msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 634msgid "SUN4U-8001-6Q.action" 635msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" 636# 637# code: SUN4U-8001-7C 638# keys: defect.io.pci.driver fault.io.datapath fault.io.pci.bus 639# 640msgid "SUN4U-8001-7C.type" 641msgstr "Fault" 642msgid "SUN4U-8001-7C.severity" 643msgstr "Critical" 644msgid "SUN4U-8001-7C.description" 645msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." 646msgid "SUN4U-8001-7C.response" 647msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 648msgid "SUN4U-8001-7C.impact" 649msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 650msgid "SUN4U-8001-7C.action" 651msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" 652# 653# code: SUN4U-8001-83 654# keys: fault.io.datapath fault.io.pci.device 655# 656msgid "SUN4U-8001-83.type" 657msgstr "Fault" 658msgid "SUN4U-8001-83.severity" 659msgstr "Critical" 660msgid "SUN4U-8001-83.description" 661msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." 662msgid "SUN4U-8001-83.response" 663msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 664msgid "SUN4U-8001-83.impact" 665msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 666msgid "SUN4U-8001-83.action" 667msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" 668# 669# code: SUN4U-8001-9Y 670# keys: defect.io.pci.driver fault.io.datapath fault.io.pci.device 671# 672msgid "SUN4U-8001-9Y.type" 673msgstr "Fault" 674msgid "SUN4U-8001-9Y.severity" 675msgstr "Critical" 676msgid "SUN4U-8001-9Y.description" 677msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." 678msgid "SUN4U-8001-9Y.response" 679msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 680msgid "SUN4U-8001-9Y.impact" 681msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 682msgid "SUN4U-8001-9Y.action" 683msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" 684# 685# code: SUN4U-8001-AD 686# keys: fault.io.datapath fault.io.pci.bus fault.io.pci.device 687# 688msgid "SUN4U-8001-AD.type" 689msgstr "Fault" 690msgid "SUN4U-8001-AD.severity" 691msgstr "Critical" 692msgid "SUN4U-8001-AD.description" 693msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." 694msgid "SUN4U-8001-AD.response" 695msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 696msgid "SUN4U-8001-AD.impact" 697msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 698msgid "SUN4U-8001-AD.action" 699msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" 700# 701# code: SUN4U-8001-CH 702# keys: defect.io.pci.driver fault.io.datapath fault.io.pci.bus fault.io.pci.device 703# 704msgid "SUN4U-8001-CH.type" 705msgstr "Fault" 706msgid "SUN4U-8001-CH.severity" 707msgstr "Critical" 708msgid "SUN4U-8001-CH.description" 709msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." 710msgid "SUN4U-8001-CH.response" 711msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 712msgid "SUN4U-8001-CH.impact" 713msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 714msgid "SUN4U-8001-CH.action" 715msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" 716# 717# code: SUN4U-8001-DA 718# keys: fault.io.hbus 719# 720msgid "SUN4U-8001-DA.type" 721msgstr "Fault" 722msgid "SUN4U-8001-DA.severity" 723msgstr "Critical" 724msgid "SUN4U-8001-DA.description" 725msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." 726msgid "SUN4U-8001-DA.response" 727msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 728msgid "SUN4U-8001-DA.impact" 729msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 730msgid "SUN4U-8001-DA.action" 731msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" 732# 733# code: SUN4U-8001-EP 734# keys: defect.io.pci.driver fault.io.hbus 735# 736msgid "SUN4U-8001-EP.type" 737msgstr "Fault" 738msgid "SUN4U-8001-EP.severity" 739msgstr "Critical" 740msgid "SUN4U-8001-EP.description" 741msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." 742msgid "SUN4U-8001-EP.response" 743msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 744msgid "SUN4U-8001-EP.impact" 745msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 746msgid "SUN4U-8001-EP.action" 747msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" 748# 749# code: SUN4U-8001-F5 750# keys: fault.io.hbus fault.io.pci.bus 751# 752msgid "SUN4U-8001-F5.type" 753msgstr "Fault" 754msgid "SUN4U-8001-F5.severity" 755msgstr "Critical" 756msgid "SUN4U-8001-F5.description" 757msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." 758msgid "SUN4U-8001-F5.response" 759msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 760msgid "SUN4U-8001-F5.impact" 761msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 762msgid "SUN4U-8001-F5.action" 763msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" 764# 765# code: SUN4U-8001-GS 766# keys: defect.io.pci.driver fault.io.hbus fault.io.pci.bus 767# 768msgid "SUN4U-8001-GS.type" 769msgstr "Fault" 770msgid "SUN4U-8001-GS.severity" 771msgstr "Critical" 772msgid "SUN4U-8001-GS.description" 773msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." 774msgid "SUN4U-8001-GS.response" 775msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 776msgid "SUN4U-8001-GS.impact" 777msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 778msgid "SUN4U-8001-GS.action" 779msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" 780# 781# code: SUN4U-8001-H2 782# keys: fault.io.hbus fault.io.pci.device 783# 784msgid "SUN4U-8001-H2.type" 785msgstr "Fault" 786msgid "SUN4U-8001-H2.severity" 787msgstr "Critical" 788msgid "SUN4U-8001-H2.description" 789msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." 790msgid "SUN4U-8001-H2.response" 791msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 792msgid "SUN4U-8001-H2.impact" 793msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 794msgid "SUN4U-8001-H2.action" 795msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" 796# 797# code: SUN4U-8001-JX 798# keys: defect.io.pci.driver fault.io.hbus fault.io.pci.device 799# 800msgid "SUN4U-8001-JX.type" 801msgstr "Fault" 802msgid "SUN4U-8001-JX.severity" 803msgstr "Critical" 804msgid "SUN4U-8001-JX.description" 805msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." 806msgid "SUN4U-8001-JX.response" 807msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 808msgid "SUN4U-8001-JX.impact" 809msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 810msgid "SUN4U-8001-JX.action" 811msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" 812# 813# code: SUN4U-8001-KE 814# keys: fault.io.hbus fault.io.pci.bus fault.io.pci.device 815# 816msgid "SUN4U-8001-KE.type" 817msgstr "Fault" 818msgid "SUN4U-8001-KE.severity" 819msgstr "Critical" 820msgid "SUN4U-8001-KE.description" 821msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." 822msgid "SUN4U-8001-KE.response" 823msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 824msgid "SUN4U-8001-KE.impact" 825msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 826msgid "SUN4U-8001-KE.action" 827msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" 828# 829# code: SUN4U-8001-LJ 830# keys: defect.io.pci.driver fault.io.hbus fault.io.pci.bus fault.io.pci.device 831# 832msgid "SUN4U-8001-LJ.type" 833msgstr "Fault" 834msgid "SUN4U-8001-LJ.severity" 835msgstr "Critical" 836msgid "SUN4U-8001-LJ.description" 837msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." 838msgid "SUN4U-8001-LJ.response" 839msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 840msgid "SUN4U-8001-LJ.impact" 841msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 842msgid "SUN4U-8001-LJ.action" 843msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" 844# 845# code: SUN4U-8001-MC 846# keys: fault.io.datapath fault.io.hbus 847# 848msgid "SUN4U-8001-MC.type" 849msgstr "Fault" 850msgid "SUN4U-8001-MC.severity" 851msgstr "Critical" 852msgid "SUN4U-8001-MC.description" 853msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." 854msgid "SUN4U-8001-MC.response" 855msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 856msgid "SUN4U-8001-MC.impact" 857msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 858msgid "SUN4U-8001-MC.action" 859msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" 860# 861# code: SUN4U-8001-NQ 862# keys: defect.io.pci.driver fault.io.datapath fault.io.hbus 863# 864msgid "SUN4U-8001-NQ.type" 865msgstr "Fault" 866msgid "SUN4U-8001-NQ.severity" 867msgstr "Critical" 868msgid "SUN4U-8001-NQ.description" 869msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." 870msgid "SUN4U-8001-NQ.response" 871msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 872msgid "SUN4U-8001-NQ.impact" 873msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 874msgid "SUN4U-8001-NQ.action" 875msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" 876# 877# code: SUN4U-8001-P4 878# keys: fault.io.datapath fault.io.hbus fault.io.pci.bus 879# 880msgid "SUN4U-8001-P4.type" 881msgstr "Fault" 882msgid "SUN4U-8001-P4.severity" 883msgstr "Critical" 884msgid "SUN4U-8001-P4.description" 885msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." 886msgid "SUN4U-8001-P4.response" 887msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 888msgid "SUN4U-8001-P4.impact" 889msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 890msgid "SUN4U-8001-P4.action" 891msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" 892# 893# code: SUN4U-8001-QR 894# keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.pci.bus 895# 896msgid "SUN4U-8001-QR.type" 897msgstr "Fault" 898msgid "SUN4U-8001-QR.severity" 899msgstr "Critical" 900msgid "SUN4U-8001-QR.description" 901msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." 902msgid "SUN4U-8001-QR.response" 903msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 904msgid "SUN4U-8001-QR.impact" 905msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 906msgid "SUN4U-8001-QR.action" 907msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" 908# 909# code: SUN4U-8001-RH 910# keys: fault.io.datapath fault.io.hbus fault.io.pci.device 911# 912msgid "SUN4U-8001-RH.type" 913msgstr "Fault" 914msgid "SUN4U-8001-RH.severity" 915msgstr "Critical" 916msgid "SUN4U-8001-RH.description" 917msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." 918msgid "SUN4U-8001-RH.response" 919msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 920msgid "SUN4U-8001-RH.impact" 921msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 922msgid "SUN4U-8001-RH.action" 923msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" 924# 925# code: SUN4U-8001-SD 926# keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.pci.device 927# 928msgid "SUN4U-8001-SD.type" 929msgstr "Fault" 930msgid "SUN4U-8001-SD.severity" 931msgstr "Critical" 932msgid "SUN4U-8001-SD.description" 933msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." 934msgid "SUN4U-8001-SD.response" 935msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 936msgid "SUN4U-8001-SD.impact" 937msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 938msgid "SUN4U-8001-SD.action" 939msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" 940# 941# code: SUN4U-8001-TY 942# keys: fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.pci.device 943# 944msgid "SUN4U-8001-TY.type" 945msgstr "Fault" 946msgid "SUN4U-8001-TY.severity" 947msgstr "Critical" 948msgid "SUN4U-8001-TY.description" 949msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." 950msgid "SUN4U-8001-TY.response" 951msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 952msgid "SUN4U-8001-TY.impact" 953msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 954msgid "SUN4U-8001-TY.action" 955msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" 956# 957# code: SUN4U-8001-U3 958# keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.pci.device 959# 960msgid "SUN4U-8001-U3.type" 961msgstr "Fault" 962msgid "SUN4U-8001-U3.severity" 963msgstr "Critical" 964msgid "SUN4U-8001-U3.description" 965msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." 966msgid "SUN4U-8001-U3.response" 967msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 968msgid "SUN4U-8001-U3.impact" 969msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 970msgid "SUN4U-8001-U3.action" 971msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" 972# 973# code: SUN4U-8001-VS 974# keys: fault.io.schizo 975# 976msgid "SUN4U-8001-VS.type" 977msgstr "Fault" 978msgid "SUN4U-8001-VS.severity" 979msgstr "Critical" 980msgid "SUN4U-8001-VS.description" 981msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." 982msgid "SUN4U-8001-VS.response" 983msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 984msgid "SUN4U-8001-VS.impact" 985msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 986msgid "SUN4U-8001-VS.action" 987msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" 988# 989# code: SUN4U-8001-W5 990# keys: defect.io.pci.driver fault.io.schizo 991# 992msgid "SUN4U-8001-W5.type" 993msgstr "Fault" 994msgid "SUN4U-8001-W5.severity" 995msgstr "Critical" 996msgid "SUN4U-8001-W5.description" 997msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." 998msgid "SUN4U-8001-W5.response" 999msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 1000msgid "SUN4U-8001-W5.impact" 1001msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 1002msgid "SUN4U-8001-W5.action" 1003msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" 1004# 1005# code: SUN4U-8001-XP 1006# keys: fault.io.pci.bus fault.io.schizo 1007# 1008msgid "SUN4U-8001-XP.type" 1009msgstr "Fault" 1010msgid "SUN4U-8001-XP.severity" 1011msgstr "Critical" 1012msgid "SUN4U-8001-XP.description" 1013msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." 1014msgid "SUN4U-8001-XP.response" 1015msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 1016msgid "SUN4U-8001-XP.impact" 1017msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 1018msgid "SUN4U-8001-XP.action" 1019msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" 1020# 1021# code: SUN4U-8001-YA 1022# keys: defect.io.pci.driver fault.io.pci.bus fault.io.schizo 1023# 1024msgid "SUN4U-8001-YA.type" 1025msgstr "Fault" 1026msgid "SUN4U-8001-YA.severity" 1027msgstr "Critical" 1028msgid "SUN4U-8001-YA.description" 1029msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." 1030msgid "SUN4U-8001-YA.response" 1031msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 1032msgid "SUN4U-8001-YA.impact" 1033msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 1034msgid "SUN4U-8001-YA.action" 1035msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" 1036# 1037# code: SUN4U-8002-0R 1038# keys: fault.io.pci.device fault.io.schizo 1039# 1040msgid "SUN4U-8002-0R.type" 1041msgstr "Fault" 1042msgid "SUN4U-8002-0R.severity" 1043msgstr "Critical" 1044msgid "SUN4U-8002-0R.description" 1045msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." 1046msgid "SUN4U-8002-0R.response" 1047msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 1048msgid "SUN4U-8002-0R.impact" 1049msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 1050msgid "SUN4U-8002-0R.action" 1051msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" 1052# 1053# code: SUN4U-8002-14 1054# keys: defect.io.pci.driver fault.io.pci.device fault.io.schizo 1055# 1056msgid "SUN4U-8002-14.type" 1057msgstr "Fault" 1058msgid "SUN4U-8002-14.severity" 1059msgstr "Critical" 1060msgid "SUN4U-8002-14.description" 1061msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." 1062msgid "SUN4U-8002-14.response" 1063msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 1064msgid "SUN4U-8002-14.impact" 1065msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 1066msgid "SUN4U-8002-14.action" 1067msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" 1068# 1069# code: SUN4U-8002-2Q 1070# keys: fault.io.pci.bus fault.io.pci.device fault.io.schizo 1071# 1072msgid "SUN4U-8002-2Q.type" 1073msgstr "Fault" 1074msgid "SUN4U-8002-2Q.severity" 1075msgstr "Critical" 1076msgid "SUN4U-8002-2Q.description" 1077msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." 1078msgid "SUN4U-8002-2Q.response" 1079msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 1080msgid "SUN4U-8002-2Q.impact" 1081msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 1082msgid "SUN4U-8002-2Q.action" 1083msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" 1084# 1085# code: SUN4U-8002-3C 1086# keys: defect.io.pci.driver fault.io.pci.bus fault.io.pci.device fault.io.schizo 1087# 1088msgid "SUN4U-8002-3C.type" 1089msgstr "Fault" 1090msgid "SUN4U-8002-3C.severity" 1091msgstr "Critical" 1092msgid "SUN4U-8002-3C.description" 1093msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." 1094msgid "SUN4U-8002-3C.response" 1095msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 1096msgid "SUN4U-8002-3C.impact" 1097msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 1098msgid "SUN4U-8002-3C.action" 1099msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" 1100# 1101# code: SUN4U-8002-4J 1102# keys: fault.io.datapath fault.io.schizo 1103# 1104msgid "SUN4U-8002-4J.type" 1105msgstr "Fault" 1106msgid "SUN4U-8002-4J.severity" 1107msgstr "Critical" 1108msgid "SUN4U-8002-4J.description" 1109msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." 1110msgid "SUN4U-8002-4J.response" 1111msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 1112msgid "SUN4U-8002-4J.impact" 1113msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 1114msgid "SUN4U-8002-4J.action" 1115msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" 1116# 1117# code: SUN4U-8002-5E 1118# keys: defect.io.pci.driver fault.io.datapath fault.io.schizo 1119# 1120msgid "SUN4U-8002-5E.type" 1121msgstr "Fault" 1122msgid "SUN4U-8002-5E.severity" 1123msgstr "Critical" 1124msgid "SUN4U-8002-5E.description" 1125msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." 1126msgid "SUN4U-8002-5E.response" 1127msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 1128msgid "SUN4U-8002-5E.impact" 1129msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 1130msgid "SUN4U-8002-5E.action" 1131msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" 1132# 1133# code: SUN4U-8002-6X 1134# keys: fault.io.datapath fault.io.pci.bus fault.io.schizo 1135# 1136msgid "SUN4U-8002-6X.type" 1137msgstr "Fault" 1138msgid "SUN4U-8002-6X.severity" 1139msgstr "Critical" 1140msgid "SUN4U-8002-6X.description" 1141msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." 1142msgid "SUN4U-8002-6X.response" 1143msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 1144msgid "SUN4U-8002-6X.impact" 1145msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 1146msgid "SUN4U-8002-6X.action" 1147msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" 1148# 1149# code: SUN4U-8002-72 1150# keys: defect.io.pci.driver fault.io.datapath fault.io.pci.bus fault.io.schizo 1151# 1152msgid "SUN4U-8002-72.type" 1153msgstr "Fault" 1154msgid "SUN4U-8002-72.severity" 1155msgstr "Critical" 1156msgid "SUN4U-8002-72.description" 1157msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." 1158msgid "SUN4U-8002-72.response" 1159msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 1160msgid "SUN4U-8002-72.impact" 1161msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 1162msgid "SUN4U-8002-72.action" 1163msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" 1164# 1165# code: SUN4U-8002-8A 1166# keys: fault.io.datapath fault.io.pci.device fault.io.schizo 1167# 1168msgid "SUN4U-8002-8A.type" 1169msgstr "Fault" 1170msgid "SUN4U-8002-8A.severity" 1171msgstr "Critical" 1172msgid "SUN4U-8002-8A.description" 1173msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." 1174msgid "SUN4U-8002-8A.response" 1175msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 1176msgid "SUN4U-8002-8A.impact" 1177msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 1178msgid "SUN4U-8002-8A.action" 1179msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" 1180# 1181# code: SUN4U-8002-9P 1182# keys: defect.io.pci.driver fault.io.datapath fault.io.pci.device fault.io.schizo 1183# 1184msgid "SUN4U-8002-9P.type" 1185msgstr "Fault" 1186msgid "SUN4U-8002-9P.severity" 1187msgstr "Critical" 1188msgid "SUN4U-8002-9P.description" 1189msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." 1190msgid "SUN4U-8002-9P.response" 1191msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 1192msgid "SUN4U-8002-9P.impact" 1193msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 1194msgid "SUN4U-8002-9P.action" 1195msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" 1196# 1197# code: SUN4U-8002-A5 1198# keys: fault.io.datapath fault.io.pci.bus fault.io.pci.device fault.io.schizo 1199# 1200msgid "SUN4U-8002-A5.type" 1201msgstr "Fault" 1202msgid "SUN4U-8002-A5.severity" 1203msgstr "Critical" 1204msgid "SUN4U-8002-A5.description" 1205msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." 1206msgid "SUN4U-8002-A5.response" 1207msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 1208msgid "SUN4U-8002-A5.impact" 1209msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 1210msgid "SUN4U-8002-A5.action" 1211msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" 1212# 1213# code: SUN4U-8002-CS 1214# keys: defect.io.pci.driver fault.io.datapath fault.io.pci.bus fault.io.pci.device fault.io.schizo 1215# 1216msgid "SUN4U-8002-CS.type" 1217msgstr "Fault" 1218msgid "SUN4U-8002-CS.severity" 1219msgstr "Critical" 1220msgid "SUN4U-8002-CS.description" 1221msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." 1222msgid "SUN4U-8002-CS.response" 1223msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 1224msgid "SUN4U-8002-CS.impact" 1225msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 1226msgid "SUN4U-8002-CS.action" 1227msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" 1228# 1229# code: SUN4U-8002-D3 1230# keys: fault.io.hbus fault.io.schizo 1231# 1232msgid "SUN4U-8002-D3.type" 1233msgstr "Fault" 1234msgid "SUN4U-8002-D3.severity" 1235msgstr "Critical" 1236msgid "SUN4U-8002-D3.description" 1237msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." 1238msgid "SUN4U-8002-D3.response" 1239msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 1240msgid "SUN4U-8002-D3.impact" 1241msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 1242msgid "SUN4U-8002-D3.action" 1243msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" 1244# 1245# code: SUN4U-8002-EY 1246# keys: defect.io.pci.driver fault.io.hbus fault.io.schizo 1247# 1248msgid "SUN4U-8002-EY.type" 1249msgstr "Fault" 1250msgid "SUN4U-8002-EY.severity" 1251msgstr "Critical" 1252msgid "SUN4U-8002-EY.description" 1253msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." 1254msgid "SUN4U-8002-EY.response" 1255msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 1256msgid "SUN4U-8002-EY.impact" 1257msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 1258msgid "SUN4U-8002-EY.action" 1259msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" 1260# 1261# code: SUN4U-8002-FD 1262# keys: fault.io.hbus fault.io.pci.bus fault.io.schizo 1263# 1264msgid "SUN4U-8002-FD.type" 1265msgstr "Fault" 1266msgid "SUN4U-8002-FD.severity" 1267msgstr "Critical" 1268msgid "SUN4U-8002-FD.description" 1269msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." 1270msgid "SUN4U-8002-FD.response" 1271msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 1272msgid "SUN4U-8002-FD.impact" 1273msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 1274msgid "SUN4U-8002-FD.action" 1275msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" 1276# 1277# code: SUN4U-8002-GH 1278# keys: defect.io.pci.driver fault.io.hbus fault.io.pci.bus fault.io.schizo 1279# 1280msgid "SUN4U-8002-GH.type" 1281msgstr "Fault" 1282msgid "SUN4U-8002-GH.severity" 1283msgstr "Critical" 1284msgid "SUN4U-8002-GH.description" 1285msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." 1286msgid "SUN4U-8002-GH.response" 1287msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 1288msgid "SUN4U-8002-GH.impact" 1289msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 1290msgid "SUN4U-8002-GH.action" 1291msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" 1292# 1293# code: SUN4U-8002-HC 1294# keys: fault.io.hbus fault.io.pci.device fault.io.schizo 1295# 1296msgid "SUN4U-8002-HC.type" 1297msgstr "Fault" 1298msgid "SUN4U-8002-HC.severity" 1299msgstr "Critical" 1300msgid "SUN4U-8002-HC.description" 1301msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." 1302msgid "SUN4U-8002-HC.response" 1303msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 1304msgid "SUN4U-8002-HC.impact" 1305msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 1306msgid "SUN4U-8002-HC.action" 1307msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" 1308# 1309# code: SUN4U-8002-JQ 1310# keys: defect.io.pci.driver fault.io.hbus fault.io.pci.device fault.io.schizo 1311# 1312msgid "SUN4U-8002-JQ.type" 1313msgstr "Fault" 1314msgid "SUN4U-8002-JQ.severity" 1315msgstr "Critical" 1316msgid "SUN4U-8002-JQ.description" 1317msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." 1318msgid "SUN4U-8002-JQ.response" 1319msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 1320msgid "SUN4U-8002-JQ.impact" 1321msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 1322msgid "SUN4U-8002-JQ.action" 1323msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" 1324# 1325# code: SUN4U-8002-K4 1326# keys: fault.io.hbus fault.io.pci.bus fault.io.pci.device fault.io.schizo 1327# 1328msgid "SUN4U-8002-K4.type" 1329msgstr "Fault" 1330msgid "SUN4U-8002-K4.severity" 1331msgstr "Critical" 1332msgid "SUN4U-8002-K4.description" 1333msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." 1334msgid "SUN4U-8002-K4.response" 1335msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 1336msgid "SUN4U-8002-K4.impact" 1337msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 1338msgid "SUN4U-8002-K4.action" 1339msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" 1340# 1341# code: SUN4U-8002-LR 1342# keys: defect.io.pci.driver fault.io.hbus fault.io.pci.bus fault.io.pci.device fault.io.schizo 1343# 1344msgid "SUN4U-8002-LR.type" 1345msgstr "Fault" 1346msgid "SUN4U-8002-LR.severity" 1347msgstr "Critical" 1348msgid "SUN4U-8002-LR.description" 1349msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." 1350msgid "SUN4U-8002-LR.response" 1351msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 1352msgid "SUN4U-8002-LR.impact" 1353msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 1354msgid "SUN4U-8002-LR.action" 1355msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" 1356# 1357# code: SUN4U-8002-M2 1358# keys: fault.io.datapath fault.io.hbus fault.io.schizo 1359# 1360msgid "SUN4U-8002-M2.type" 1361msgstr "Fault" 1362msgid "SUN4U-8002-M2.severity" 1363msgstr "Critical" 1364msgid "SUN4U-8002-M2.description" 1365msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." 1366msgid "SUN4U-8002-M2.response" 1367msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 1368msgid "SUN4U-8002-M2.impact" 1369msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 1370msgid "SUN4U-8002-M2.action" 1371msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" 1372# 1373# code: SUN4U-8002-NX 1374# keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.schizo 1375# 1376msgid "SUN4U-8002-NX.type" 1377msgstr "Fault" 1378msgid "SUN4U-8002-NX.severity" 1379msgstr "Critical" 1380msgid "SUN4U-8002-NX.description" 1381msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." 1382msgid "SUN4U-8002-NX.response" 1383msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 1384msgid "SUN4U-8002-NX.impact" 1385msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 1386msgid "SUN4U-8002-NX.action" 1387msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" 1388# 1389# code: SUN4U-8002-PE 1390# keys: fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.schizo 1391# 1392msgid "SUN4U-8002-PE.type" 1393msgstr "Fault" 1394msgid "SUN4U-8002-PE.severity" 1395msgstr "Critical" 1396msgid "SUN4U-8002-PE.description" 1397msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." 1398msgid "SUN4U-8002-PE.response" 1399msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 1400msgid "SUN4U-8002-PE.impact" 1401msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 1402msgid "SUN4U-8002-PE.action" 1403msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" 1404# 1405# code: SUN4U-8002-QJ 1406# keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.schizo 1407# 1408msgid "SUN4U-8002-QJ.type" 1409msgstr "Fault" 1410msgid "SUN4U-8002-QJ.severity" 1411msgstr "Critical" 1412msgid "SUN4U-8002-QJ.description" 1413msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." 1414msgid "SUN4U-8002-QJ.response" 1415msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 1416msgid "SUN4U-8002-QJ.impact" 1417msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 1418msgid "SUN4U-8002-QJ.action" 1419msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" 1420# 1421# code: SUN4U-8002-RS 1422# keys: fault.io.datapath fault.io.hbus fault.io.pci.device fault.io.schizo 1423# 1424msgid "SUN4U-8002-RS.type" 1425msgstr "Fault" 1426msgid "SUN4U-8002-RS.severity" 1427msgstr "Critical" 1428msgid "SUN4U-8002-RS.description" 1429msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." 1430msgid "SUN4U-8002-RS.response" 1431msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 1432msgid "SUN4U-8002-RS.impact" 1433msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 1434msgid "SUN4U-8002-RS.action" 1435msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" 1436# 1437# code: SUN4U-8002-S5 1438# keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.pci.device fault.io.schizo 1439# 1440msgid "SUN4U-8002-S5.type" 1441msgstr "Fault" 1442msgid "SUN4U-8002-S5.severity" 1443msgstr "Critical" 1444msgid "SUN4U-8002-S5.description" 1445msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." 1446msgid "SUN4U-8002-S5.response" 1447msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 1448msgid "SUN4U-8002-S5.impact" 1449msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 1450msgid "SUN4U-8002-S5.action" 1451msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" 1452# 1453# code: SUN4U-8002-TP 1454# keys: fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.pci.device fault.io.schizo 1455# 1456msgid "SUN4U-8002-TP.type" 1457msgstr "Fault" 1458msgid "SUN4U-8002-TP.severity" 1459msgstr "Critical" 1460msgid "SUN4U-8002-TP.description" 1461msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." 1462msgid "SUN4U-8002-TP.response" 1463msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 1464msgid "SUN4U-8002-TP.impact" 1465msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 1466msgid "SUN4U-8002-TP.action" 1467msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" 1468# 1469# code: SUN4U-8002-UA 1470# keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.pci.device fault.io.schizo 1471# 1472msgid "SUN4U-8002-UA.type" 1473msgstr "Fault" 1474msgid "SUN4U-8002-UA.severity" 1475msgstr "Critical" 1476msgid "SUN4U-8002-UA.description" 1477msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." 1478msgid "SUN4U-8002-UA.response" 1479msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 1480msgid "SUN4U-8002-UA.impact" 1481msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 1482msgid "SUN4U-8002-UA.action" 1483msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" 1484# 1485# code: SUN4U-8002-VH 1486# keys: fault.io.xmits 1487# 1488msgid "SUN4U-8002-VH.type" 1489msgstr "Fault" 1490msgid "SUN4U-8002-VH.severity" 1491msgstr "Critical" 1492msgid "SUN4U-8002-VH.description" 1493msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." 1494msgid "SUN4U-8002-VH.response" 1495msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 1496msgid "SUN4U-8002-VH.impact" 1497msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 1498msgid "SUN4U-8002-VH.action" 1499msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" 1500# 1501# code: SUN4U-8002-WD 1502# keys: defect.io.pci.driver fault.io.xmits 1503# 1504msgid "SUN4U-8002-WD.type" 1505msgstr "Fault" 1506msgid "SUN4U-8002-WD.severity" 1507msgstr "Critical" 1508msgid "SUN4U-8002-WD.description" 1509msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." 1510msgid "SUN4U-8002-WD.response" 1511msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 1512msgid "SUN4U-8002-WD.impact" 1513msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 1514msgid "SUN4U-8002-WD.action" 1515msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" 1516# 1517# code: SUN4U-8002-XY 1518# keys: fault.io.pci.bus fault.io.xmits 1519# 1520msgid "SUN4U-8002-XY.type" 1521msgstr "Fault" 1522msgid "SUN4U-8002-XY.severity" 1523msgstr "Critical" 1524msgid "SUN4U-8002-XY.description" 1525msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." 1526msgid "SUN4U-8002-XY.response" 1527msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 1528msgid "SUN4U-8002-XY.impact" 1529msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 1530msgid "SUN4U-8002-XY.action" 1531msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" 1532# 1533# code: SUN4U-8002-Y3 1534# keys: defect.io.pci.driver fault.io.pci.bus fault.io.xmits 1535# 1536msgid "SUN4U-8002-Y3.type" 1537msgstr "Fault" 1538msgid "SUN4U-8002-Y3.severity" 1539msgstr "Critical" 1540msgid "SUN4U-8002-Y3.description" 1541msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." 1542msgid "SUN4U-8002-Y3.response" 1543msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 1544msgid "SUN4U-8002-Y3.impact" 1545msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 1546msgid "SUN4U-8002-Y3.action" 1547msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" 1548# 1549# code: SUN4U-8003-0Y 1550# keys: fault.io.pci.device fault.io.xmits 1551# 1552msgid "SUN4U-8003-0Y.type" 1553msgstr "Fault" 1554msgid "SUN4U-8003-0Y.severity" 1555msgstr "Critical" 1556msgid "SUN4U-8003-0Y.description" 1557msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." 1558msgid "SUN4U-8003-0Y.response" 1559msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 1560msgid "SUN4U-8003-0Y.impact" 1561msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 1562msgid "SUN4U-8003-0Y.action" 1563msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" 1564# 1565# code: SUN4U-8003-13 1566# keys: defect.io.pci.driver fault.io.pci.device fault.io.xmits 1567# 1568msgid "SUN4U-8003-13.type" 1569msgstr "Fault" 1570msgid "SUN4U-8003-13.severity" 1571msgstr "Critical" 1572msgid "SUN4U-8003-13.description" 1573msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." 1574msgid "SUN4U-8003-13.response" 1575msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 1576msgid "SUN4U-8003-13.impact" 1577msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 1578msgid "SUN4U-8003-13.action" 1579msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" 1580# 1581# code: SUN4U-8003-2H 1582# keys: fault.io.pci.bus fault.io.pci.device fault.io.xmits 1583# 1584msgid "SUN4U-8003-2H.type" 1585msgstr "Fault" 1586msgid "SUN4U-8003-2H.severity" 1587msgstr "Critical" 1588msgid "SUN4U-8003-2H.description" 1589msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." 1590msgid "SUN4U-8003-2H.response" 1591msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 1592msgid "SUN4U-8003-2H.impact" 1593msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 1594msgid "SUN4U-8003-2H.action" 1595msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" 1596# 1597# code: SUN4U-8003-3D 1598# keys: defect.io.pci.driver fault.io.pci.bus fault.io.pci.device fault.io.xmits 1599# 1600msgid "SUN4U-8003-3D.type" 1601msgstr "Fault" 1602msgid "SUN4U-8003-3D.severity" 1603msgstr "Critical" 1604msgid "SUN4U-8003-3D.description" 1605msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." 1606msgid "SUN4U-8003-3D.response" 1607msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 1608msgid "SUN4U-8003-3D.impact" 1609msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 1610msgid "SUN4U-8003-3D.action" 1611msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" 1612# 1613# code: SUN4U-8003-4P 1614# keys: fault.io.datapath fault.io.xmits 1615# 1616msgid "SUN4U-8003-4P.type" 1617msgstr "Fault" 1618msgid "SUN4U-8003-4P.severity" 1619msgstr "Critical" 1620msgid "SUN4U-8003-4P.description" 1621msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." 1622msgid "SUN4U-8003-4P.response" 1623msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 1624msgid "SUN4U-8003-4P.impact" 1625msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 1626msgid "SUN4U-8003-4P.action" 1627msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" 1628# 1629# code: SUN4U-8003-5A 1630# keys: defect.io.pci.driver fault.io.datapath fault.io.xmits 1631# 1632msgid "SUN4U-8003-5A.type" 1633msgstr "Fault" 1634msgid "SUN4U-8003-5A.severity" 1635msgstr "Critical" 1636msgid "SUN4U-8003-5A.description" 1637msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." 1638msgid "SUN4U-8003-5A.response" 1639msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 1640msgid "SUN4U-8003-5A.impact" 1641msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 1642msgid "SUN4U-8003-5A.action" 1643msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" 1644# 1645# code: SUN4U-8003-6S 1646# keys: fault.io.datapath fault.io.pci.bus fault.io.xmits 1647# 1648msgid "SUN4U-8003-6S.type" 1649msgstr "Fault" 1650msgid "SUN4U-8003-6S.severity" 1651msgstr "Critical" 1652msgid "SUN4U-8003-6S.description" 1653msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." 1654msgid "SUN4U-8003-6S.response" 1655msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 1656msgid "SUN4U-8003-6S.impact" 1657msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 1658msgid "SUN4U-8003-6S.action" 1659msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" 1660# 1661# code: SUN4U-8003-75 1662# keys: defect.io.pci.driver fault.io.datapath fault.io.pci.bus fault.io.xmits 1663# 1664msgid "SUN4U-8003-75.type" 1665msgstr "Fault" 1666msgid "SUN4U-8003-75.severity" 1667msgstr "Critical" 1668msgid "SUN4U-8003-75.description" 1669msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." 1670msgid "SUN4U-8003-75.response" 1671msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 1672msgid "SUN4U-8003-75.impact" 1673msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 1674msgid "SUN4U-8003-75.action" 1675msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" 1676# 1677# code: SUN4U-8003-8E 1678# keys: fault.io.datapath fault.io.pci.device fault.io.xmits 1679# 1680msgid "SUN4U-8003-8E.type" 1681msgstr "Fault" 1682msgid "SUN4U-8003-8E.severity" 1683msgstr "Critical" 1684msgid "SUN4U-8003-8E.description" 1685msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." 1686msgid "SUN4U-8003-8E.response" 1687msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 1688msgid "SUN4U-8003-8E.impact" 1689msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 1690msgid "SUN4U-8003-8E.action" 1691msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" 1692# 1693# code: SUN4U-8003-9J 1694# keys: defect.io.pci.driver fault.io.datapath fault.io.pci.device fault.io.xmits 1695# 1696msgid "SUN4U-8003-9J.type" 1697msgstr "Fault" 1698msgid "SUN4U-8003-9J.severity" 1699msgstr "Critical" 1700msgid "SUN4U-8003-9J.description" 1701msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." 1702msgid "SUN4U-8003-9J.response" 1703msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 1704msgid "SUN4U-8003-9J.impact" 1705msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 1706msgid "SUN4U-8003-9J.action" 1707msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" 1708# 1709# code: SUN4U-8003-A2 1710# keys: fault.io.datapath fault.io.pci.bus fault.io.pci.device fault.io.xmits 1711# 1712msgid "SUN4U-8003-A2.type" 1713msgstr "Fault" 1714msgid "SUN4U-8003-A2.severity" 1715msgstr "Critical" 1716msgid "SUN4U-8003-A2.description" 1717msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." 1718msgid "SUN4U-8003-A2.response" 1719msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 1720msgid "SUN4U-8003-A2.impact" 1721msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 1722msgid "SUN4U-8003-A2.action" 1723msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" 1724# 1725# code: SUN4U-8003-CX 1726# keys: defect.io.pci.driver fault.io.datapath fault.io.pci.bus fault.io.pci.device fault.io.xmits 1727# 1728msgid "SUN4U-8003-CX.type" 1729msgstr "Fault" 1730msgid "SUN4U-8003-CX.severity" 1731msgstr "Critical" 1732msgid "SUN4U-8003-CX.description" 1733msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." 1734msgid "SUN4U-8003-CX.response" 1735msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 1736msgid "SUN4U-8003-CX.impact" 1737msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 1738msgid "SUN4U-8003-CX.action" 1739msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" 1740# 1741# code: SUN4U-8003-D4 1742# keys: fault.io.hbus fault.io.xmits 1743# 1744msgid "SUN4U-8003-D4.type" 1745msgstr "Fault" 1746msgid "SUN4U-8003-D4.severity" 1747msgstr "Critical" 1748msgid "SUN4U-8003-D4.description" 1749msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." 1750msgid "SUN4U-8003-D4.response" 1751msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 1752msgid "SUN4U-8003-D4.impact" 1753msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 1754msgid "SUN4U-8003-D4.action" 1755msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" 1756# 1757# code: SUN4U-8003-ER 1758# keys: defect.io.pci.driver fault.io.hbus fault.io.xmits 1759# 1760msgid "SUN4U-8003-ER.type" 1761msgstr "Fault" 1762msgid "SUN4U-8003-ER.severity" 1763msgstr "Critical" 1764msgid "SUN4U-8003-ER.description" 1765msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." 1766msgid "SUN4U-8003-ER.response" 1767msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 1768msgid "SUN4U-8003-ER.impact" 1769msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 1770msgid "SUN4U-8003-ER.action" 1771msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" 1772# 1773# code: SUN4U-8003-FC 1774# keys: fault.io.hbus fault.io.pci.bus fault.io.xmits 1775# 1776msgid "SUN4U-8003-FC.type" 1777msgstr "Fault" 1778msgid "SUN4U-8003-FC.severity" 1779msgstr "Critical" 1780msgid "SUN4U-8003-FC.description" 1781msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." 1782msgid "SUN4U-8003-FC.response" 1783msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 1784msgid "SUN4U-8003-FC.impact" 1785msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 1786msgid "SUN4U-8003-FC.action" 1787msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" 1788# 1789# code: SUN4U-8003-GQ 1790# keys: defect.io.pci.driver fault.io.hbus fault.io.pci.bus fault.io.xmits 1791# 1792msgid "SUN4U-8003-GQ.type" 1793msgstr "Fault" 1794msgid "SUN4U-8003-GQ.severity" 1795msgstr "Critical" 1796msgid "SUN4U-8003-GQ.description" 1797msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." 1798msgid "SUN4U-8003-GQ.response" 1799msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 1800msgid "SUN4U-8003-GQ.impact" 1801msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 1802msgid "SUN4U-8003-GQ.action" 1803msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" 1804# 1805# code: SUN4U-8003-HD 1806# keys: fault.io.hbus fault.io.pci.device fault.io.xmits 1807# 1808msgid "SUN4U-8003-HD.type" 1809msgstr "Fault" 1810msgid "SUN4U-8003-HD.severity" 1811msgstr "Critical" 1812msgid "SUN4U-8003-HD.description" 1813msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." 1814msgid "SUN4U-8003-HD.response" 1815msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 1816msgid "SUN4U-8003-HD.impact" 1817msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 1818msgid "SUN4U-8003-HD.action" 1819msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" 1820# 1821# code: SUN4U-8003-JH 1822# keys: defect.io.pci.driver fault.io.hbus fault.io.pci.device fault.io.xmits 1823# 1824msgid "SUN4U-8003-JH.type" 1825msgstr "Fault" 1826msgid "SUN4U-8003-JH.severity" 1827msgstr "Critical" 1828msgid "SUN4U-8003-JH.description" 1829msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." 1830msgid "SUN4U-8003-JH.response" 1831msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 1832msgid "SUN4U-8003-JH.impact" 1833msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 1834msgid "SUN4U-8003-JH.action" 1835msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" 1836# 1837# code: SUN4U-8003-K3 1838# keys: fault.io.hbus fault.io.pci.bus fault.io.pci.device fault.io.xmits 1839# 1840msgid "SUN4U-8003-K3.type" 1841msgstr "Fault" 1842msgid "SUN4U-8003-K3.severity" 1843msgstr "Critical" 1844msgid "SUN4U-8003-K3.description" 1845msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." 1846msgid "SUN4U-8003-K3.response" 1847msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 1848msgid "SUN4U-8003-K3.impact" 1849msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 1850msgid "SUN4U-8003-K3.action" 1851msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" 1852# 1853# code: SUN4U-8003-LY 1854# keys: defect.io.pci.driver fault.io.hbus fault.io.pci.bus fault.io.pci.device fault.io.xmits 1855# 1856msgid "SUN4U-8003-LY.type" 1857msgstr "Fault" 1858msgid "SUN4U-8003-LY.severity" 1859msgstr "Critical" 1860msgid "SUN4U-8003-LY.description" 1861msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." 1862msgid "SUN4U-8003-LY.response" 1863msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 1864msgid "SUN4U-8003-LY.impact" 1865msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 1866msgid "SUN4U-8003-LY.action" 1867msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" 1868# 1869# code: SUN4U-8003-M5 1870# keys: fault.io.datapath fault.io.hbus fault.io.xmits 1871# 1872msgid "SUN4U-8003-M5.type" 1873msgstr "Fault" 1874msgid "SUN4U-8003-M5.severity" 1875msgstr "Critical" 1876msgid "SUN4U-8003-M5.description" 1877msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." 1878msgid "SUN4U-8003-M5.response" 1879msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 1880msgid "SUN4U-8003-M5.impact" 1881msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 1882msgid "SUN4U-8003-M5.action" 1883msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" 1884# 1885# code: SUN4U-8003-NS 1886# keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.xmits 1887# 1888msgid "SUN4U-8003-NS.type" 1889msgstr "Fault" 1890msgid "SUN4U-8003-NS.severity" 1891msgstr "Critical" 1892msgid "SUN4U-8003-NS.description" 1893msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." 1894msgid "SUN4U-8003-NS.response" 1895msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 1896msgid "SUN4U-8003-NS.impact" 1897msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 1898msgid "SUN4U-8003-NS.action" 1899msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" 1900# 1901# code: SUN4U-8003-PA 1902# keys: fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.xmits 1903# 1904msgid "SUN4U-8003-PA.type" 1905msgstr "Fault" 1906msgid "SUN4U-8003-PA.severity" 1907msgstr "Critical" 1908msgid "SUN4U-8003-PA.description" 1909msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." 1910msgid "SUN4U-8003-PA.response" 1911msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 1912msgid "SUN4U-8003-PA.impact" 1913msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 1914msgid "SUN4U-8003-PA.action" 1915msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" 1916# 1917# code: SUN4U-8003-QP 1918# keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.xmits 1919# 1920msgid "SUN4U-8003-QP.type" 1921msgstr "Fault" 1922msgid "SUN4U-8003-QP.severity" 1923msgstr "Critical" 1924msgid "SUN4U-8003-QP.description" 1925msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." 1926msgid "SUN4U-8003-QP.response" 1927msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 1928msgid "SUN4U-8003-QP.impact" 1929msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 1930msgid "SUN4U-8003-QP.action" 1931msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" 1932# 1933# code: SUN4U-8003-RX 1934# keys: fault.io.datapath fault.io.hbus fault.io.pci.device fault.io.xmits 1935# 1936msgid "SUN4U-8003-RX.type" 1937msgstr "Fault" 1938msgid "SUN4U-8003-RX.severity" 1939msgstr "Critical" 1940msgid "SUN4U-8003-RX.description" 1941msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." 1942msgid "SUN4U-8003-RX.response" 1943msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 1944msgid "SUN4U-8003-RX.impact" 1945msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 1946msgid "SUN4U-8003-RX.action" 1947msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" 1948# 1949# code: SUN4U-8003-S2 1950# keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.pci.device fault.io.xmits 1951# 1952msgid "SUN4U-8003-S2.type" 1953msgstr "Fault" 1954msgid "SUN4U-8003-S2.severity" 1955msgstr "Critical" 1956msgid "SUN4U-8003-S2.description" 1957msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." 1958msgid "SUN4U-8003-S2.response" 1959msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 1960msgid "SUN4U-8003-S2.impact" 1961msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 1962msgid "SUN4U-8003-S2.action" 1963msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" 1964# 1965# code: SUN4U-8003-TJ 1966# keys: fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.pci.device fault.io.xmits 1967# 1968msgid "SUN4U-8003-TJ.type" 1969msgstr "Fault" 1970msgid "SUN4U-8003-TJ.severity" 1971msgstr "Critical" 1972msgid "SUN4U-8003-TJ.description" 1973msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." 1974msgid "SUN4U-8003-TJ.response" 1975msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 1976msgid "SUN4U-8003-TJ.impact" 1977msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 1978msgid "SUN4U-8003-TJ.action" 1979msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" 1980# 1981# code: SUN4U-8003-UE 1982# keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.pci.device fault.io.xmits 1983# 1984msgid "SUN4U-8003-UE.type" 1985msgstr "Fault" 1986msgid "SUN4U-8003-UE.severity" 1987msgstr "Critical" 1988msgid "SUN4U-8003-UE.description" 1989msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." 1990msgid "SUN4U-8003-UE.response" 1991msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 1992msgid "SUN4U-8003-UE.impact" 1993msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 1994msgid "SUN4U-8003-UE.action" 1995msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" 1996# 1997# code: SUN4U-8003-VQ 1998# keys: fault.io.schizo fault.io.xmits 1999# 2000msgid "SUN4U-8003-VQ.type" 2001msgstr "Fault" 2002msgid "SUN4U-8003-VQ.severity" 2003msgstr "Critical" 2004msgid "SUN4U-8003-VQ.description" 2005msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." 2006msgid "SUN4U-8003-VQ.response" 2007msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 2008msgid "SUN4U-8003-VQ.impact" 2009msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 2010msgid "SUN4U-8003-VQ.action" 2011msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" 2012# 2013# code: SUN4U-8003-WC 2014# keys: defect.io.pci.driver fault.io.schizo fault.io.xmits 2015# 2016msgid "SUN4U-8003-WC.type" 2017msgstr "Fault" 2018msgid "SUN4U-8003-WC.severity" 2019msgstr "Critical" 2020msgid "SUN4U-8003-WC.description" 2021msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." 2022msgid "SUN4U-8003-WC.response" 2023msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 2024msgid "SUN4U-8003-WC.impact" 2025msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 2026msgid "SUN4U-8003-WC.action" 2027msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" 2028# 2029# code: SUN4U-8003-XR 2030# keys: fault.io.pci.bus fault.io.schizo fault.io.xmits 2031# 2032msgid "SUN4U-8003-XR.type" 2033msgstr "Fault" 2034msgid "SUN4U-8003-XR.severity" 2035msgstr "Critical" 2036msgid "SUN4U-8003-XR.description" 2037msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." 2038msgid "SUN4U-8003-XR.response" 2039msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 2040msgid "SUN4U-8003-XR.impact" 2041msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 2042msgid "SUN4U-8003-XR.action" 2043msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" 2044# 2045# code: SUN4U-8003-Y4 2046# keys: defect.io.pci.driver fault.io.pci.bus fault.io.schizo fault.io.xmits 2047# 2048msgid "SUN4U-8003-Y4.type" 2049msgstr "Fault" 2050msgid "SUN4U-8003-Y4.severity" 2051msgstr "Critical" 2052msgid "SUN4U-8003-Y4.description" 2053msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." 2054msgid "SUN4U-8003-Y4.response" 2055msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 2056msgid "SUN4U-8003-Y4.impact" 2057msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 2058msgid "SUN4U-8003-Y4.action" 2059msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" 2060# 2061# code: SUN4U-8004-0A 2062# keys: fault.io.pci.device fault.io.schizo fault.io.xmits 2063# 2064msgid "SUN4U-8004-0A.type" 2065msgstr "Fault" 2066msgid "SUN4U-8004-0A.severity" 2067msgstr "Critical" 2068msgid "SUN4U-8004-0A.description" 2069msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." 2070msgid "SUN4U-8004-0A.response" 2071msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 2072msgid "SUN4U-8004-0A.impact" 2073msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 2074msgid "SUN4U-8004-0A.action" 2075msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" 2076# 2077# code: SUN4U-8004-1P 2078# keys: defect.io.pci.driver fault.io.pci.device fault.io.schizo fault.io.xmits 2079# 2080msgid "SUN4U-8004-1P.type" 2081msgstr "Fault" 2082msgid "SUN4U-8004-1P.severity" 2083msgstr "Critical" 2084msgid "SUN4U-8004-1P.description" 2085msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." 2086msgid "SUN4U-8004-1P.response" 2087msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 2088msgid "SUN4U-8004-1P.impact" 2089msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 2090msgid "SUN4U-8004-1P.action" 2091msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" 2092# 2093# code: SUN4U-8004-25 2094# keys: fault.io.pci.bus fault.io.pci.device fault.io.schizo fault.io.xmits 2095# 2096msgid "SUN4U-8004-25.type" 2097msgstr "Fault" 2098msgid "SUN4U-8004-25.severity" 2099msgstr "Critical" 2100msgid "SUN4U-8004-25.description" 2101msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." 2102msgid "SUN4U-8004-25.response" 2103msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 2104msgid "SUN4U-8004-25.impact" 2105msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 2106msgid "SUN4U-8004-25.action" 2107msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" 2108# 2109# code: SUN4U-8004-3S 2110# keys: defect.io.pci.driver fault.io.pci.bus fault.io.pci.device fault.io.schizo fault.io.xmits 2111# 2112msgid "SUN4U-8004-3S.type" 2113msgstr "Fault" 2114msgid "SUN4U-8004-3S.severity" 2115msgstr "Critical" 2116msgid "SUN4U-8004-3S.description" 2117msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." 2118msgid "SUN4U-8004-3S.response" 2119msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 2120msgid "SUN4U-8004-3S.impact" 2121msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 2122msgid "SUN4U-8004-3S.action" 2123msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" 2124# 2125# code: SUN4U-8004-43 2126# keys: fault.io.datapath fault.io.schizo fault.io.xmits 2127# 2128msgid "SUN4U-8004-43.type" 2129msgstr "Fault" 2130msgid "SUN4U-8004-43.severity" 2131msgstr "Critical" 2132msgid "SUN4U-8004-43.description" 2133msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." 2134msgid "SUN4U-8004-43.response" 2135msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 2136msgid "SUN4U-8004-43.impact" 2137msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 2138msgid "SUN4U-8004-43.action" 2139msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" 2140# 2141# code: SUN4U-8004-5Y 2142# keys: defect.io.pci.driver fault.io.datapath fault.io.schizo fault.io.xmits 2143# 2144msgid "SUN4U-8004-5Y.type" 2145msgstr "Fault" 2146msgid "SUN4U-8004-5Y.severity" 2147msgstr "Critical" 2148msgid "SUN4U-8004-5Y.description" 2149msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." 2150msgid "SUN4U-8004-5Y.response" 2151msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 2152msgid "SUN4U-8004-5Y.impact" 2153msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 2154msgid "SUN4U-8004-5Y.action" 2155msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" 2156# 2157# code: SUN4U-8004-6D 2158# keys: fault.io.datapath fault.io.pci.bus fault.io.schizo fault.io.xmits 2159# 2160msgid "SUN4U-8004-6D.type" 2161msgstr "Fault" 2162msgid "SUN4U-8004-6D.severity" 2163msgstr "Critical" 2164msgid "SUN4U-8004-6D.description" 2165msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." 2166msgid "SUN4U-8004-6D.response" 2167msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 2168msgid "SUN4U-8004-6D.impact" 2169msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 2170msgid "SUN4U-8004-6D.action" 2171msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" 2172# 2173# code: SUN4U-8004-7H 2174# keys: defect.io.pci.driver fault.io.datapath fault.io.pci.bus fault.io.schizo fault.io.xmits 2175# 2176msgid "SUN4U-8004-7H.type" 2177msgstr "Fault" 2178msgid "SUN4U-8004-7H.severity" 2179msgstr "Critical" 2180msgid "SUN4U-8004-7H.description" 2181msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." 2182msgid "SUN4U-8004-7H.response" 2183msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 2184msgid "SUN4U-8004-7H.impact" 2185msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 2186msgid "SUN4U-8004-7H.action" 2187msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" 2188# 2189# code: SUN4U-8004-8R 2190# keys: fault.io.datapath fault.io.pci.device fault.io.schizo fault.io.xmits 2191# 2192msgid "SUN4U-8004-8R.type" 2193msgstr "Fault" 2194msgid "SUN4U-8004-8R.severity" 2195msgstr "Critical" 2196msgid "SUN4U-8004-8R.description" 2197msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." 2198msgid "SUN4U-8004-8R.response" 2199msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 2200msgid "SUN4U-8004-8R.impact" 2201msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 2202msgid "SUN4U-8004-8R.action" 2203msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" 2204# 2205# code: SUN4U-8004-94 2206# keys: defect.io.pci.driver fault.io.datapath fault.io.pci.device fault.io.schizo fault.io.xmits 2207# 2208msgid "SUN4U-8004-94.type" 2209msgstr "Fault" 2210msgid "SUN4U-8004-94.severity" 2211msgstr "Critical" 2212msgid "SUN4U-8004-94.description" 2213msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." 2214msgid "SUN4U-8004-94.response" 2215msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 2216msgid "SUN4U-8004-94.impact" 2217msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 2218msgid "SUN4U-8004-94.action" 2219msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" 2220# 2221# code: SUN4U-8004-AQ 2222# keys: fault.io.datapath fault.io.pci.bus fault.io.pci.device fault.io.schizo fault.io.xmits 2223# 2224msgid "SUN4U-8004-AQ.type" 2225msgstr "Fault" 2226msgid "SUN4U-8004-AQ.severity" 2227msgstr "Critical" 2228msgid "SUN4U-8004-AQ.description" 2229msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." 2230msgid "SUN4U-8004-AQ.response" 2231msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 2232msgid "SUN4U-8004-AQ.impact" 2233msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 2234msgid "SUN4U-8004-AQ.action" 2235msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" 2236# 2237# code: SUN4U-8004-CC 2238# keys: defect.io.pci.driver fault.io.datapath fault.io.pci.bus fault.io.pci.device fault.io.schizo fault.io.xmits 2239# 2240msgid "SUN4U-8004-CC.type" 2241msgstr "Fault" 2242msgid "SUN4U-8004-CC.severity" 2243msgstr "Critical" 2244msgid "SUN4U-8004-CC.description" 2245msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." 2246msgid "SUN4U-8004-CC.response" 2247msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 2248msgid "SUN4U-8004-CC.impact" 2249msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 2250msgid "SUN4U-8004-CC.action" 2251msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" 2252# 2253# code: SUN4U-8004-DJ 2254# keys: fault.io.hbus fault.io.schizo fault.io.xmits 2255# 2256msgid "SUN4U-8004-DJ.type" 2257msgstr "Fault" 2258msgid "SUN4U-8004-DJ.severity" 2259msgstr "Critical" 2260msgid "SUN4U-8004-DJ.description" 2261msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." 2262msgid "SUN4U-8004-DJ.response" 2263msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 2264msgid "SUN4U-8004-DJ.impact" 2265msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 2266msgid "SUN4U-8004-DJ.action" 2267msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" 2268# 2269# code: SUN4U-8004-EE 2270# keys: defect.io.pci.driver fault.io.hbus fault.io.schizo fault.io.xmits 2271# 2272msgid "SUN4U-8004-EE.type" 2273msgstr "Fault" 2274msgid "SUN4U-8004-EE.severity" 2275msgstr "Critical" 2276msgid "SUN4U-8004-EE.description" 2277msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." 2278msgid "SUN4U-8004-EE.response" 2279msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 2280msgid "SUN4U-8004-EE.impact" 2281msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 2282msgid "SUN4U-8004-EE.action" 2283msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" 2284# 2285# code: SUN4U-8004-FX 2286# keys: fault.io.hbus fault.io.pci.bus fault.io.schizo fault.io.xmits 2287# 2288msgid "SUN4U-8004-FX.type" 2289msgstr "Fault" 2290msgid "SUN4U-8004-FX.severity" 2291msgstr "Critical" 2292msgid "SUN4U-8004-FX.description" 2293msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." 2294msgid "SUN4U-8004-FX.response" 2295msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 2296msgid "SUN4U-8004-FX.impact" 2297msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 2298msgid "SUN4U-8004-FX.action" 2299msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" 2300# 2301# code: SUN4U-8004-G2 2302# keys: defect.io.pci.driver fault.io.hbus fault.io.pci.bus fault.io.schizo fault.io.xmits 2303# 2304msgid "SUN4U-8004-G2.type" 2305msgstr "Fault" 2306msgid "SUN4U-8004-G2.severity" 2307msgstr "Critical" 2308msgid "SUN4U-8004-G2.description" 2309msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." 2310msgid "SUN4U-8004-G2.response" 2311msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 2312msgid "SUN4U-8004-G2.impact" 2313msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 2314msgid "SUN4U-8004-G2.action" 2315msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" 2316# 2317# code: SUN4U-8004-HS 2318# keys: fault.io.hbus fault.io.pci.device fault.io.schizo fault.io.xmits 2319# 2320msgid "SUN4U-8004-HS.type" 2321msgstr "Fault" 2322msgid "SUN4U-8004-HS.severity" 2323msgstr "Critical" 2324msgid "SUN4U-8004-HS.description" 2325msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." 2326msgid "SUN4U-8004-HS.response" 2327msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 2328msgid "SUN4U-8004-HS.impact" 2329msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 2330msgid "SUN4U-8004-HS.action" 2331msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" 2332# 2333# code: SUN4U-8004-J5 2334# keys: defect.io.pci.driver fault.io.hbus fault.io.pci.device fault.io.schizo fault.io.xmits 2335# 2336msgid "SUN4U-8004-J5.type" 2337msgstr "Fault" 2338msgid "SUN4U-8004-J5.severity" 2339msgstr "Critical" 2340msgid "SUN4U-8004-J5.description" 2341msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." 2342msgid "SUN4U-8004-J5.response" 2343msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 2344msgid "SUN4U-8004-J5.impact" 2345msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 2346msgid "SUN4U-8004-J5.action" 2347msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" 2348# 2349# code: SUN4U-8004-KP 2350# keys: fault.io.hbus fault.io.pci.bus fault.io.pci.device fault.io.schizo fault.io.xmits 2351# 2352msgid "SUN4U-8004-KP.type" 2353msgstr "Fault" 2354msgid "SUN4U-8004-KP.severity" 2355msgstr "Critical" 2356msgid "SUN4U-8004-KP.description" 2357msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." 2358msgid "SUN4U-8004-KP.response" 2359msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 2360msgid "SUN4U-8004-KP.impact" 2361msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 2362msgid "SUN4U-8004-KP.action" 2363msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" 2364# 2365# code: SUN4U-8004-LA 2366# keys: defect.io.pci.driver fault.io.hbus fault.io.pci.bus fault.io.pci.device fault.io.schizo fault.io.xmits 2367# 2368msgid "SUN4U-8004-LA.type" 2369msgstr "Fault" 2370msgid "SUN4U-8004-LA.severity" 2371msgstr "Critical" 2372msgid "SUN4U-8004-LA.description" 2373msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." 2374msgid "SUN4U-8004-LA.response" 2375msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 2376msgid "SUN4U-8004-LA.impact" 2377msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 2378msgid "SUN4U-8004-LA.action" 2379msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" 2380# 2381# code: SUN4U-8004-MH 2382# keys: fault.io.datapath fault.io.hbus fault.io.schizo fault.io.xmits 2383# 2384msgid "SUN4U-8004-MH.type" 2385msgstr "Fault" 2386msgid "SUN4U-8004-MH.severity" 2387msgstr "Critical" 2388msgid "SUN4U-8004-MH.description" 2389msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." 2390msgid "SUN4U-8004-MH.response" 2391msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 2392msgid "SUN4U-8004-MH.impact" 2393msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 2394msgid "SUN4U-8004-MH.action" 2395msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" 2396# 2397# code: SUN4U-8004-ND 2398# keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.schizo fault.io.xmits 2399# 2400msgid "SUN4U-8004-ND.type" 2401msgstr "Fault" 2402msgid "SUN4U-8004-ND.severity" 2403msgstr "Critical" 2404msgid "SUN4U-8004-ND.description" 2405msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." 2406msgid "SUN4U-8004-ND.response" 2407msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 2408msgid "SUN4U-8004-ND.impact" 2409msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 2410msgid "SUN4U-8004-ND.action" 2411msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" 2412# 2413# code: SUN4U-8004-PY 2414# keys: fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.schizo fault.io.xmits 2415# 2416msgid "SUN4U-8004-PY.type" 2417msgstr "Fault" 2418msgid "SUN4U-8004-PY.severity" 2419msgstr "Critical" 2420msgid "SUN4U-8004-PY.description" 2421msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." 2422msgid "SUN4U-8004-PY.response" 2423msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 2424msgid "SUN4U-8004-PY.impact" 2425msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 2426msgid "SUN4U-8004-PY.action" 2427msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" 2428# 2429# code: SUN4U-8004-Q3 2430# keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.schizo fault.io.xmits 2431# 2432msgid "SUN4U-8004-Q3.type" 2433msgstr "Fault" 2434msgid "SUN4U-8004-Q3.severity" 2435msgstr "Critical" 2436msgid "SUN4U-8004-Q3.description" 2437msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." 2438msgid "SUN4U-8004-Q3.response" 2439msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 2440msgid "SUN4U-8004-Q3.impact" 2441msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 2442msgid "SUN4U-8004-Q3.action" 2443msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" 2444# 2445# code: SUN4U-8004-RC 2446# keys: fault.io.datapath fault.io.hbus fault.io.pci.device fault.io.schizo fault.io.xmits 2447# 2448msgid "SUN4U-8004-RC.type" 2449msgstr "Fault" 2450msgid "SUN4U-8004-RC.severity" 2451msgstr "Critical" 2452msgid "SUN4U-8004-RC.description" 2453msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." 2454msgid "SUN4U-8004-RC.response" 2455msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 2456msgid "SUN4U-8004-RC.impact" 2457msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 2458msgid "SUN4U-8004-RC.action" 2459msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" 2460# 2461# code: SUN4U-8004-SQ 2462# keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.pci.device fault.io.schizo fault.io.xmits 2463# 2464msgid "SUN4U-8004-SQ.type" 2465msgstr "Fault" 2466msgid "SUN4U-8004-SQ.severity" 2467msgstr "Critical" 2468msgid "SUN4U-8004-SQ.description" 2469msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." 2470msgid "SUN4U-8004-SQ.response" 2471msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 2472msgid "SUN4U-8004-SQ.impact" 2473msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 2474msgid "SUN4U-8004-SQ.action" 2475msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" 2476# 2477# code: SUN4U-8004-T4 2478# keys: fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.pci.device fault.io.schizo fault.io.xmits 2479# 2480msgid "SUN4U-8004-T4.type" 2481msgstr "Fault" 2482msgid "SUN4U-8004-T4.severity" 2483msgstr "Critical" 2484msgid "SUN4U-8004-T4.description" 2485msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." 2486msgid "SUN4U-8004-T4.response" 2487msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 2488msgid "SUN4U-8004-T4.impact" 2489msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 2490msgid "SUN4U-8004-T4.action" 2491msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" 2492# 2493# code: SUN4U-8004-UR 2494# keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.pci.device fault.io.schizo fault.io.xmits 2495# 2496msgid "SUN4U-8004-UR.type" 2497msgstr "Fault" 2498msgid "SUN4U-8004-UR.severity" 2499msgstr "Critical" 2500msgid "SUN4U-8004-UR.description" 2501msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." 2502msgid "SUN4U-8004-UR.response" 2503msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 2504msgid "SUN4U-8004-UR.impact" 2505msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 2506msgid "SUN4U-8004-UR.action" 2507msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" 2508# 2509# code: SUN4U-8004-V2 2510# keys: fault.io.psycho 2511# 2512msgid "SUN4U-8004-V2.type" 2513msgstr "Fault" 2514msgid "SUN4U-8004-V2.severity" 2515msgstr "Critical" 2516msgid "SUN4U-8004-V2.description" 2517msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." 2518msgid "SUN4U-8004-V2.response" 2519msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 2520msgid "SUN4U-8004-V2.impact" 2521msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 2522msgid "SUN4U-8004-V2.action" 2523msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" 2524# 2525# code: SUN4U-8004-WX 2526# keys: defect.io.pci.driver fault.io.psycho 2527# 2528msgid "SUN4U-8004-WX.type" 2529msgstr "Fault" 2530msgid "SUN4U-8004-WX.severity" 2531msgstr "Critical" 2532msgid "SUN4U-8004-WX.description" 2533msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." 2534msgid "SUN4U-8004-WX.response" 2535msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 2536msgid "SUN4U-8004-WX.impact" 2537msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 2538msgid "SUN4U-8004-WX.action" 2539msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" 2540# 2541# code: SUN4U-8004-XE 2542# keys: fault.io.datapath fault.io.psycho 2543# 2544msgid "SUN4U-8004-XE.type" 2545msgstr "Fault" 2546msgid "SUN4U-8004-XE.severity" 2547msgstr "Critical" 2548msgid "SUN4U-8004-XE.description" 2549msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." 2550msgid "SUN4U-8004-XE.response" 2551msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 2552msgid "SUN4U-8004-XE.impact" 2553msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 2554msgid "SUN4U-8004-XE.action" 2555msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" 2556# 2557# code: SUN4U-8004-YJ 2558# keys: defect.io.pci.driver fault.io.datapath fault.io.psycho 2559# 2560msgid "SUN4U-8004-YJ.type" 2561msgstr "Fault" 2562msgid "SUN4U-8004-YJ.severity" 2563msgstr "Critical" 2564msgid "SUN4U-8004-YJ.description" 2565msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." 2566msgid "SUN4U-8004-YJ.response" 2567msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 2568msgid "SUN4U-8004-YJ.impact" 2569msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 2570msgid "SUN4U-8004-YJ.action" 2571msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" 2572# 2573# code: SUN4U-8005-0E 2574# keys: fault.io.hbus fault.io.psycho 2575# 2576msgid "SUN4U-8005-0E.type" 2577msgstr "Fault" 2578msgid "SUN4U-8005-0E.severity" 2579msgstr "Critical" 2580msgid "SUN4U-8005-0E.description" 2581msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." 2582msgid "SUN4U-8005-0E.response" 2583msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 2584msgid "SUN4U-8005-0E.impact" 2585msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 2586msgid "SUN4U-8005-0E.action" 2587msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" 2588# 2589# code: SUN4U-8005-1J 2590# keys: defect.io.pci.driver fault.io.hbus fault.io.psycho 2591# 2592msgid "SUN4U-8005-1J.type" 2593msgstr "Fault" 2594msgid "SUN4U-8005-1J.severity" 2595msgstr "Critical" 2596msgid "SUN4U-8005-1J.description" 2597msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." 2598msgid "SUN4U-8005-1J.response" 2599msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 2600msgid "SUN4U-8005-1J.impact" 2601msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 2602msgid "SUN4U-8005-1J.action" 2603msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" 2604# 2605# code: SUN4U-8005-22 2606# keys: fault.io.datapath fault.io.hbus fault.io.psycho 2607# 2608msgid "SUN4U-8005-22.type" 2609msgstr "Fault" 2610msgid "SUN4U-8005-22.severity" 2611msgstr "Critical" 2612msgid "SUN4U-8005-22.description" 2613msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." 2614msgid "SUN4U-8005-22.response" 2615msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 2616msgid "SUN4U-8005-22.impact" 2617msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 2618msgid "SUN4U-8005-22.action" 2619msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" 2620# 2621# code: SUN4U-8005-3X 2622# keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.psycho 2623# 2624msgid "SUN4U-8005-3X.type" 2625msgstr "Fault" 2626msgid "SUN4U-8005-3X.severity" 2627msgstr "Critical" 2628msgid "SUN4U-8005-3X.description" 2629msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." 2630msgid "SUN4U-8005-3X.response" 2631msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 2632msgid "SUN4U-8005-3X.impact" 2633msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 2634msgid "SUN4U-8005-3X.action" 2635msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" 2636# 2637# code: SUN4U-8005-44 2638# keys: fault.io.pci.bus fault.io.psycho 2639# 2640msgid "SUN4U-8005-44.type" 2641msgstr "Fault" 2642msgid "SUN4U-8005-44.severity" 2643msgstr "Critical" 2644msgid "SUN4U-8005-44.description" 2645msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." 2646msgid "SUN4U-8005-44.response" 2647msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 2648msgid "SUN4U-8005-44.impact" 2649msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 2650msgid "SUN4U-8005-44.action" 2651msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" 2652# 2653# code: SUN4U-8005-5R 2654# keys: defect.io.pci.driver fault.io.pci.bus fault.io.psycho 2655# 2656msgid "SUN4U-8005-5R.type" 2657msgstr "Fault" 2658msgid "SUN4U-8005-5R.severity" 2659msgstr "Critical" 2660msgid "SUN4U-8005-5R.description" 2661msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." 2662msgid "SUN4U-8005-5R.response" 2663msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 2664msgid "SUN4U-8005-5R.impact" 2665msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 2666msgid "SUN4U-8005-5R.action" 2667msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" 2668# 2669# code: SUN4U-8005-6C 2670# keys: fault.io.datapath fault.io.pci.bus fault.io.psycho 2671# 2672msgid "SUN4U-8005-6C.type" 2673msgstr "Fault" 2674msgid "SUN4U-8005-6C.severity" 2675msgstr "Critical" 2676msgid "SUN4U-8005-6C.description" 2677msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." 2678msgid "SUN4U-8005-6C.response" 2679msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 2680msgid "SUN4U-8005-6C.impact" 2681msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 2682msgid "SUN4U-8005-6C.action" 2683msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" 2684# 2685# code: SUN4U-8005-7Q 2686# keys: defect.io.pci.driver fault.io.datapath fault.io.pci.bus fault.io.psycho 2687# 2688msgid "SUN4U-8005-7Q.type" 2689msgstr "Fault" 2690msgid "SUN4U-8005-7Q.severity" 2691msgstr "Critical" 2692msgid "SUN4U-8005-7Q.description" 2693msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." 2694msgid "SUN4U-8005-7Q.response" 2695msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 2696msgid "SUN4U-8005-7Q.impact" 2697msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 2698msgid "SUN4U-8005-7Q.action" 2699msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" 2700# 2701# code: SUN4U-8005-8Y 2702# keys: fault.io.hbus fault.io.pci.bus fault.io.psycho 2703# 2704msgid "SUN4U-8005-8Y.type" 2705msgstr "Fault" 2706msgid "SUN4U-8005-8Y.severity" 2707msgstr "Critical" 2708msgid "SUN4U-8005-8Y.description" 2709msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." 2710msgid "SUN4U-8005-8Y.response" 2711msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 2712msgid "SUN4U-8005-8Y.impact" 2713msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 2714msgid "SUN4U-8005-8Y.action" 2715msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" 2716# 2717# code: SUN4U-8005-93 2718# keys: defect.io.pci.driver fault.io.hbus fault.io.pci.bus fault.io.psycho 2719# 2720msgid "SUN4U-8005-93.type" 2721msgstr "Fault" 2722msgid "SUN4U-8005-93.severity" 2723msgstr "Critical" 2724msgid "SUN4U-8005-93.description" 2725msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." 2726msgid "SUN4U-8005-93.response" 2727msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 2728msgid "SUN4U-8005-93.impact" 2729msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 2730msgid "SUN4U-8005-93.action" 2731msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" 2732# 2733# code: SUN4U-8005-AH 2734# keys: fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.psycho 2735# 2736msgid "SUN4U-8005-AH.type" 2737msgstr "Fault" 2738msgid "SUN4U-8005-AH.severity" 2739msgstr "Critical" 2740msgid "SUN4U-8005-AH.description" 2741msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." 2742msgid "SUN4U-8005-AH.response" 2743msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 2744msgid "SUN4U-8005-AH.impact" 2745msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 2746msgid "SUN4U-8005-AH.action" 2747msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" 2748# 2749# code: SUN4U-8005-CD 2750# keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.psycho 2751# 2752msgid "SUN4U-8005-CD.type" 2753msgstr "Fault" 2754msgid "SUN4U-8005-CD.severity" 2755msgstr "Critical" 2756msgid "SUN4U-8005-CD.description" 2757msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." 2758msgid "SUN4U-8005-CD.response" 2759msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 2760msgid "SUN4U-8005-CD.impact" 2761msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 2762msgid "SUN4U-8005-CD.action" 2763msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" 2764# 2765# code: SUN4U-8005-DP 2766# keys: fault.io.pci.device fault.io.psycho 2767# 2768msgid "SUN4U-8005-DP.type" 2769msgstr "Fault" 2770msgid "SUN4U-8005-DP.severity" 2771msgstr "Critical" 2772msgid "SUN4U-8005-DP.description" 2773msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." 2774msgid "SUN4U-8005-DP.response" 2775msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 2776msgid "SUN4U-8005-DP.impact" 2777msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 2778msgid "SUN4U-8005-DP.action" 2779msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" 2780# 2781# code: SUN4U-8005-EA 2782# keys: defect.io.pci.driver fault.io.pci.device fault.io.psycho 2783# 2784msgid "SUN4U-8005-EA.type" 2785msgstr "Fault" 2786msgid "SUN4U-8005-EA.severity" 2787msgstr "Critical" 2788msgid "SUN4U-8005-EA.description" 2789msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." 2790msgid "SUN4U-8005-EA.response" 2791msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 2792msgid "SUN4U-8005-EA.impact" 2793msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 2794msgid "SUN4U-8005-EA.action" 2795msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" 2796# 2797# code: SUN4U-8005-FS 2798# keys: fault.io.datapath fault.io.pci.device fault.io.psycho 2799# 2800msgid "SUN4U-8005-FS.type" 2801msgstr "Fault" 2802msgid "SUN4U-8005-FS.severity" 2803msgstr "Critical" 2804msgid "SUN4U-8005-FS.description" 2805msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." 2806msgid "SUN4U-8005-FS.response" 2807msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 2808msgid "SUN4U-8005-FS.impact" 2809msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 2810msgid "SUN4U-8005-FS.action" 2811msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" 2812# 2813# code: SUN4U-8005-G5 2814# keys: defect.io.pci.driver fault.io.datapath fault.io.pci.device fault.io.psycho 2815# 2816msgid "SUN4U-8005-G5.type" 2817msgstr "Fault" 2818msgid "SUN4U-8005-G5.severity" 2819msgstr "Critical" 2820msgid "SUN4U-8005-G5.description" 2821msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." 2822msgid "SUN4U-8005-G5.response" 2823msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 2824msgid "SUN4U-8005-G5.impact" 2825msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 2826msgid "SUN4U-8005-G5.action" 2827msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" 2828# 2829# code: SUN4U-8005-HX 2830# keys: fault.io.hbus fault.io.pci.device fault.io.psycho 2831# 2832msgid "SUN4U-8005-HX.type" 2833msgstr "Fault" 2834msgid "SUN4U-8005-HX.severity" 2835msgstr "Critical" 2836msgid "SUN4U-8005-HX.description" 2837msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." 2838msgid "SUN4U-8005-HX.response" 2839msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 2840msgid "SUN4U-8005-HX.impact" 2841msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 2842msgid "SUN4U-8005-HX.action" 2843msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" 2844# 2845# code: SUN4U-8005-J2 2846# keys: defect.io.pci.driver fault.io.hbus fault.io.pci.device fault.io.psycho 2847# 2848msgid "SUN4U-8005-J2.type" 2849msgstr "Fault" 2850msgid "SUN4U-8005-J2.severity" 2851msgstr "Critical" 2852msgid "SUN4U-8005-J2.description" 2853msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." 2854msgid "SUN4U-8005-J2.response" 2855msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 2856msgid "SUN4U-8005-J2.impact" 2857msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 2858msgid "SUN4U-8005-J2.action" 2859msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" 2860# 2861# code: SUN4U-8005-KJ 2862# keys: fault.io.datapath fault.io.hbus fault.io.pci.device fault.io.psycho 2863# 2864msgid "SUN4U-8005-KJ.type" 2865msgstr "Fault" 2866msgid "SUN4U-8005-KJ.severity" 2867msgstr "Critical" 2868msgid "SUN4U-8005-KJ.description" 2869msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." 2870msgid "SUN4U-8005-KJ.response" 2871msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 2872msgid "SUN4U-8005-KJ.impact" 2873msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 2874msgid "SUN4U-8005-KJ.action" 2875msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" 2876# 2877# code: SUN4U-8005-LE 2878# keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.pci.device fault.io.psycho 2879# 2880msgid "SUN4U-8005-LE.type" 2881msgstr "Fault" 2882msgid "SUN4U-8005-LE.severity" 2883msgstr "Critical" 2884msgid "SUN4U-8005-LE.description" 2885msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." 2886msgid "SUN4U-8005-LE.response" 2887msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 2888msgid "SUN4U-8005-LE.impact" 2889msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 2890msgid "SUN4U-8005-LE.action" 2891msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" 2892# 2893# code: SUN4U-8005-MQ 2894# keys: fault.io.pci.bus fault.io.pci.device fault.io.psycho 2895# 2896msgid "SUN4U-8005-MQ.type" 2897msgstr "Fault" 2898msgid "SUN4U-8005-MQ.severity" 2899msgstr "Critical" 2900msgid "SUN4U-8005-MQ.description" 2901msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." 2902msgid "SUN4U-8005-MQ.response" 2903msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 2904msgid "SUN4U-8005-MQ.impact" 2905msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 2906msgid "SUN4U-8005-MQ.action" 2907msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" 2908# 2909# code: SUN4U-8005-NC 2910# keys: defect.io.pci.driver fault.io.pci.bus fault.io.pci.device fault.io.psycho 2911# 2912msgid "SUN4U-8005-NC.type" 2913msgstr "Fault" 2914msgid "SUN4U-8005-NC.severity" 2915msgstr "Critical" 2916msgid "SUN4U-8005-NC.description" 2917msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." 2918msgid "SUN4U-8005-NC.response" 2919msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 2920msgid "SUN4U-8005-NC.impact" 2921msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 2922msgid "SUN4U-8005-NC.action" 2923msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" 2924# 2925# code: SUN4U-8005-PR 2926# keys: fault.io.datapath fault.io.pci.bus fault.io.pci.device fault.io.psycho 2927# 2928msgid "SUN4U-8005-PR.type" 2929msgstr "Fault" 2930msgid "SUN4U-8005-PR.severity" 2931msgstr "Critical" 2932msgid "SUN4U-8005-PR.description" 2933msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." 2934msgid "SUN4U-8005-PR.response" 2935msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 2936msgid "SUN4U-8005-PR.impact" 2937msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 2938msgid "SUN4U-8005-PR.action" 2939msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" 2940# 2941# code: SUN4U-8005-Q4 2942# keys: defect.io.pci.driver fault.io.datapath fault.io.pci.bus fault.io.pci.device fault.io.psycho 2943# 2944msgid "SUN4U-8005-Q4.type" 2945msgstr "Fault" 2946msgid "SUN4U-8005-Q4.severity" 2947msgstr "Critical" 2948msgid "SUN4U-8005-Q4.description" 2949msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." 2950msgid "SUN4U-8005-Q4.response" 2951msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 2952msgid "SUN4U-8005-Q4.impact" 2953msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 2954msgid "SUN4U-8005-Q4.action" 2955msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" 2956# 2957# code: SUN4U-8005-RD 2958# keys: fault.io.hbus fault.io.pci.bus fault.io.pci.device fault.io.psycho 2959# 2960msgid "SUN4U-8005-RD.type" 2961msgstr "Fault" 2962msgid "SUN4U-8005-RD.severity" 2963msgstr "Critical" 2964msgid "SUN4U-8005-RD.description" 2965msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." 2966msgid "SUN4U-8005-RD.response" 2967msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 2968msgid "SUN4U-8005-RD.impact" 2969msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 2970msgid "SUN4U-8005-RD.action" 2971msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" 2972# 2973# code: SUN4U-8005-SH 2974# keys: defect.io.pci.driver fault.io.hbus fault.io.pci.bus fault.io.pci.device fault.io.psycho 2975# 2976msgid "SUN4U-8005-SH.type" 2977msgstr "Fault" 2978msgid "SUN4U-8005-SH.severity" 2979msgstr "Critical" 2980msgid "SUN4U-8005-SH.description" 2981msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." 2982msgid "SUN4U-8005-SH.response" 2983msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 2984msgid "SUN4U-8005-SH.impact" 2985msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 2986msgid "SUN4U-8005-SH.action" 2987msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" 2988# 2989# code: SUN4U-8005-T3 2990# keys: fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.pci.device fault.io.psycho 2991# 2992msgid "SUN4U-8005-T3.type" 2993msgstr "Fault" 2994msgid "SUN4U-8005-T3.severity" 2995msgstr "Critical" 2996msgid "SUN4U-8005-T3.description" 2997msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." 2998msgid "SUN4U-8005-T3.response" 2999msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 3000msgid "SUN4U-8005-T3.impact" 3001msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 3002msgid "SUN4U-8005-T3.action" 3003msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" 3004# 3005# code: SUN4U-8005-UY 3006# keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.pci.device fault.io.psycho 3007# 3008msgid "SUN4U-8005-UY.type" 3009msgstr "Fault" 3010msgid "SUN4U-8005-UY.severity" 3011msgstr "Critical" 3012msgid "SUN4U-8005-UY.description" 3013msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." 3014msgid "SUN4U-8005-UY.response" 3015msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 3016msgid "SUN4U-8005-UY.impact" 3017msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 3018msgid "SUN4U-8005-UY.action" 3019msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" 3020# 3021# code: SUN4U-8005-V5 3022# keys: fault.io.tomatillo 3023# 3024msgid "SUN4U-8005-V5.type" 3025msgstr "Fault" 3026msgid "SUN4U-8005-V5.severity" 3027msgstr "Critical" 3028msgid "SUN4U-8005-V5.description" 3029msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." 3030msgid "SUN4U-8005-V5.response" 3031msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 3032msgid "SUN4U-8005-V5.impact" 3033msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 3034msgid "SUN4U-8005-V5.action" 3035msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" 3036# 3037# code: SUN4U-8005-WS 3038# keys: defect.io.pci.driver fault.io.tomatillo 3039# 3040msgid "SUN4U-8005-WS.type" 3041msgstr "Fault" 3042msgid "SUN4U-8005-WS.severity" 3043msgstr "Critical" 3044msgid "SUN4U-8005-WS.description" 3045msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." 3046msgid "SUN4U-8005-WS.response" 3047msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 3048msgid "SUN4U-8005-WS.impact" 3049msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 3050msgid "SUN4U-8005-WS.action" 3051msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" 3052# 3053# code: SUN4U-8005-XA 3054# keys: fault.io.datapath fault.io.tomatillo 3055# 3056msgid "SUN4U-8005-XA.type" 3057msgstr "Fault" 3058msgid "SUN4U-8005-XA.severity" 3059msgstr "Critical" 3060msgid "SUN4U-8005-XA.description" 3061msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." 3062msgid "SUN4U-8005-XA.response" 3063msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 3064msgid "SUN4U-8005-XA.impact" 3065msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 3066msgid "SUN4U-8005-XA.action" 3067msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" 3068# 3069# code: SUN4U-8005-YP 3070# keys: defect.io.pci.driver fault.io.datapath fault.io.tomatillo 3071# 3072msgid "SUN4U-8005-YP.type" 3073msgstr "Fault" 3074msgid "SUN4U-8005-YP.severity" 3075msgstr "Critical" 3076msgid "SUN4U-8005-YP.description" 3077msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." 3078msgid "SUN4U-8005-YP.response" 3079msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 3080msgid "SUN4U-8005-YP.impact" 3081msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 3082msgid "SUN4U-8005-YP.action" 3083msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" 3084# 3085# code: SUN4U-8006-04 3086# keys: fault.io.hbus fault.io.tomatillo 3087# 3088msgid "SUN4U-8006-04.type" 3089msgstr "Fault" 3090msgid "SUN4U-8006-04.severity" 3091msgstr "Critical" 3092msgid "SUN4U-8006-04.description" 3093msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." 3094msgid "SUN4U-8006-04.response" 3095msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 3096msgid "SUN4U-8006-04.impact" 3097msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 3098msgid "SUN4U-8006-04.action" 3099msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" 3100# 3101# code: SUN4U-8006-1R 3102# keys: defect.io.pci.driver fault.io.hbus fault.io.tomatillo 3103# 3104msgid "SUN4U-8006-1R.type" 3105msgstr "Fault" 3106msgid "SUN4U-8006-1R.severity" 3107msgstr "Critical" 3108msgid "SUN4U-8006-1R.description" 3109msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." 3110msgid "SUN4U-8006-1R.response" 3111msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 3112msgid "SUN4U-8006-1R.impact" 3113msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 3114msgid "SUN4U-8006-1R.action" 3115msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" 3116# 3117# code: SUN4U-8006-2C 3118# keys: fault.io.datapath fault.io.hbus fault.io.tomatillo 3119# 3120msgid "SUN4U-8006-2C.type" 3121msgstr "Fault" 3122msgid "SUN4U-8006-2C.severity" 3123msgstr "Critical" 3124msgid "SUN4U-8006-2C.description" 3125msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." 3126msgid "SUN4U-8006-2C.response" 3127msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 3128msgid "SUN4U-8006-2C.impact" 3129msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 3130msgid "SUN4U-8006-2C.action" 3131msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" 3132# 3133# code: SUN4U-8006-3Q 3134# keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.tomatillo 3135# 3136msgid "SUN4U-8006-3Q.type" 3137msgstr "Fault" 3138msgid "SUN4U-8006-3Q.severity" 3139msgstr "Critical" 3140msgid "SUN4U-8006-3Q.description" 3141msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." 3142msgid "SUN4U-8006-3Q.response" 3143msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 3144msgid "SUN4U-8006-3Q.impact" 3145msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 3146msgid "SUN4U-8006-3Q.action" 3147msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" 3148# 3149# code: SUN4U-8006-4E 3150# keys: fault.io.pci.bus fault.io.tomatillo 3151# 3152msgid "SUN4U-8006-4E.type" 3153msgstr "Fault" 3154msgid "SUN4U-8006-4E.severity" 3155msgstr "Critical" 3156msgid "SUN4U-8006-4E.description" 3157msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." 3158msgid "SUN4U-8006-4E.response" 3159msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 3160msgid "SUN4U-8006-4E.impact" 3161msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 3162msgid "SUN4U-8006-4E.action" 3163msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" 3164# 3165# code: SUN4U-8006-5J 3166# keys: defect.io.pci.driver fault.io.pci.bus fault.io.tomatillo 3167# 3168msgid "SUN4U-8006-5J.type" 3169msgstr "Fault" 3170msgid "SUN4U-8006-5J.severity" 3171msgstr "Critical" 3172msgid "SUN4U-8006-5J.description" 3173msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." 3174msgid "SUN4U-8006-5J.response" 3175msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 3176msgid "SUN4U-8006-5J.impact" 3177msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 3178msgid "SUN4U-8006-5J.action" 3179msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" 3180# 3181# code: SUN4U-8006-62 3182# keys: fault.io.datapath fault.io.pci.bus fault.io.tomatillo 3183# 3184msgid "SUN4U-8006-62.type" 3185msgstr "Fault" 3186msgid "SUN4U-8006-62.severity" 3187msgstr "Critical" 3188msgid "SUN4U-8006-62.description" 3189msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." 3190msgid "SUN4U-8006-62.response" 3191msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 3192msgid "SUN4U-8006-62.impact" 3193msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 3194msgid "SUN4U-8006-62.action" 3195msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" 3196# 3197# code: SUN4U-8006-7X 3198# keys: defect.io.pci.driver fault.io.datapath fault.io.pci.bus fault.io.tomatillo 3199# 3200msgid "SUN4U-8006-7X.type" 3201msgstr "Fault" 3202msgid "SUN4U-8006-7X.severity" 3203msgstr "Critical" 3204msgid "SUN4U-8006-7X.description" 3205msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." 3206msgid "SUN4U-8006-7X.response" 3207msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 3208msgid "SUN4U-8006-7X.impact" 3209msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 3210msgid "SUN4U-8006-7X.action" 3211msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" 3212# 3213# code: SUN4U-8006-8P 3214# keys: fault.io.hbus fault.io.pci.bus fault.io.tomatillo 3215# 3216msgid "SUN4U-8006-8P.type" 3217msgstr "Fault" 3218msgid "SUN4U-8006-8P.severity" 3219msgstr "Critical" 3220msgid "SUN4U-8006-8P.description" 3221msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." 3222msgid "SUN4U-8006-8P.response" 3223msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 3224msgid "SUN4U-8006-8P.impact" 3225msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 3226msgid "SUN4U-8006-8P.action" 3227msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" 3228# 3229# code: SUN4U-8006-9A 3230# keys: defect.io.pci.driver fault.io.hbus fault.io.pci.bus fault.io.tomatillo 3231# 3232msgid "SUN4U-8006-9A.type" 3233msgstr "Fault" 3234msgid "SUN4U-8006-9A.severity" 3235msgstr "Critical" 3236msgid "SUN4U-8006-9A.description" 3237msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." 3238msgid "SUN4U-8006-9A.response" 3239msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 3240msgid "SUN4U-8006-9A.impact" 3241msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 3242msgid "SUN4U-8006-9A.action" 3243msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" 3244# 3245# code: SUN4U-8006-AS 3246# keys: fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.tomatillo 3247# 3248msgid "SUN4U-8006-AS.type" 3249msgstr "Fault" 3250msgid "SUN4U-8006-AS.severity" 3251msgstr "Critical" 3252msgid "SUN4U-8006-AS.description" 3253msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." 3254msgid "SUN4U-8006-AS.response" 3255msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 3256msgid "SUN4U-8006-AS.impact" 3257msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 3258msgid "SUN4U-8006-AS.action" 3259msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" 3260# 3261# code: SUN4U-8006-C5 3262# keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.tomatillo 3263# 3264msgid "SUN4U-8006-C5.type" 3265msgstr "Fault" 3266msgid "SUN4U-8006-C5.severity" 3267msgstr "Critical" 3268msgid "SUN4U-8006-C5.description" 3269msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." 3270msgid "SUN4U-8006-C5.response" 3271msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 3272msgid "SUN4U-8006-C5.impact" 3273msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 3274msgid "SUN4U-8006-C5.action" 3275msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" 3276# 3277# code: SUN4U-8006-DY 3278# keys: fault.io.pci.device fault.io.tomatillo 3279# 3280msgid "SUN4U-8006-DY.type" 3281msgstr "Fault" 3282msgid "SUN4U-8006-DY.severity" 3283msgstr "Critical" 3284msgid "SUN4U-8006-DY.description" 3285msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." 3286msgid "SUN4U-8006-DY.response" 3287msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 3288msgid "SUN4U-8006-DY.impact" 3289msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 3290msgid "SUN4U-8006-DY.action" 3291msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" 3292# 3293# code: SUN4U-8006-E3 3294# keys: defect.io.pci.driver fault.io.pci.device fault.io.tomatillo 3295# 3296msgid "SUN4U-8006-E3.type" 3297msgstr "Fault" 3298msgid "SUN4U-8006-E3.severity" 3299msgstr "Critical" 3300msgid "SUN4U-8006-E3.description" 3301msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." 3302msgid "SUN4U-8006-E3.response" 3303msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 3304msgid "SUN4U-8006-E3.impact" 3305msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 3306msgid "SUN4U-8006-E3.action" 3307msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" 3308# 3309# code: SUN4U-8006-FH 3310# keys: fault.io.datapath fault.io.pci.device fault.io.tomatillo 3311# 3312msgid "SUN4U-8006-FH.type" 3313msgstr "Fault" 3314msgid "SUN4U-8006-FH.severity" 3315msgstr "Critical" 3316msgid "SUN4U-8006-FH.description" 3317msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." 3318msgid "SUN4U-8006-FH.response" 3319msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 3320msgid "SUN4U-8006-FH.impact" 3321msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 3322msgid "SUN4U-8006-FH.action" 3323msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" 3324# 3325# code: SUN4U-8006-GD 3326# keys: defect.io.pci.driver fault.io.datapath fault.io.pci.device fault.io.tomatillo 3327# 3328msgid "SUN4U-8006-GD.type" 3329msgstr "Fault" 3330msgid "SUN4U-8006-GD.severity" 3331msgstr "Critical" 3332msgid "SUN4U-8006-GD.description" 3333msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." 3334msgid "SUN4U-8006-GD.response" 3335msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 3336msgid "SUN4U-8006-GD.impact" 3337msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 3338msgid "SUN4U-8006-GD.action" 3339msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" 3340# 3341# code: SUN4U-8006-HQ 3342# keys: fault.io.hbus fault.io.pci.device fault.io.tomatillo 3343# 3344msgid "SUN4U-8006-HQ.type" 3345msgstr "Fault" 3346msgid "SUN4U-8006-HQ.severity" 3347msgstr "Critical" 3348msgid "SUN4U-8006-HQ.description" 3349msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." 3350msgid "SUN4U-8006-HQ.response" 3351msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 3352msgid "SUN4U-8006-HQ.impact" 3353msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 3354msgid "SUN4U-8006-HQ.action" 3355msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" 3356# 3357# code: SUN4U-8006-JC 3358# keys: defect.io.pci.driver fault.io.hbus fault.io.pci.device fault.io.tomatillo 3359# 3360msgid "SUN4U-8006-JC.type" 3361msgstr "Fault" 3362msgid "SUN4U-8006-JC.severity" 3363msgstr "Critical" 3364msgid "SUN4U-8006-JC.description" 3365msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." 3366msgid "SUN4U-8006-JC.response" 3367msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 3368msgid "SUN4U-8006-JC.impact" 3369msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 3370msgid "SUN4U-8006-JC.action" 3371msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" 3372# 3373# code: SUN4U-8006-KR 3374# keys: fault.io.datapath fault.io.hbus fault.io.pci.device fault.io.tomatillo 3375# 3376msgid "SUN4U-8006-KR.type" 3377msgstr "Fault" 3378msgid "SUN4U-8006-KR.severity" 3379msgstr "Critical" 3380msgid "SUN4U-8006-KR.description" 3381msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." 3382msgid "SUN4U-8006-KR.response" 3383msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 3384msgid "SUN4U-8006-KR.impact" 3385msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 3386msgid "SUN4U-8006-KR.action" 3387msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" 3388# 3389# code: SUN4U-8006-L4 3390# keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.pci.device fault.io.tomatillo 3391# 3392msgid "SUN4U-8006-L4.type" 3393msgstr "Fault" 3394msgid "SUN4U-8006-L4.severity" 3395msgstr "Critical" 3396msgid "SUN4U-8006-L4.description" 3397msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." 3398msgid "SUN4U-8006-L4.response" 3399msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 3400msgid "SUN4U-8006-L4.impact" 3401msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 3402msgid "SUN4U-8006-L4.action" 3403msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" 3404# 3405# code: SUN4U-8006-MX 3406# keys: fault.io.pci.bus fault.io.pci.device fault.io.tomatillo 3407# 3408msgid "SUN4U-8006-MX.type" 3409msgstr "Fault" 3410msgid "SUN4U-8006-MX.severity" 3411msgstr "Critical" 3412msgid "SUN4U-8006-MX.description" 3413msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." 3414msgid "SUN4U-8006-MX.response" 3415msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 3416msgid "SUN4U-8006-MX.impact" 3417msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 3418msgid "SUN4U-8006-MX.action" 3419msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" 3420# 3421# code: SUN4U-8006-N2 3422# keys: defect.io.pci.driver fault.io.pci.bus fault.io.pci.device fault.io.tomatillo 3423# 3424msgid "SUN4U-8006-N2.type" 3425msgstr "Fault" 3426msgid "SUN4U-8006-N2.severity" 3427msgstr "Critical" 3428msgid "SUN4U-8006-N2.description" 3429msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." 3430msgid "SUN4U-8006-N2.response" 3431msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 3432msgid "SUN4U-8006-N2.impact" 3433msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 3434msgid "SUN4U-8006-N2.action" 3435msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" 3436# 3437# code: SUN4U-8006-PJ 3438# keys: fault.io.datapath fault.io.pci.bus fault.io.pci.device fault.io.tomatillo 3439# 3440msgid "SUN4U-8006-PJ.type" 3441msgstr "Fault" 3442msgid "SUN4U-8006-PJ.severity" 3443msgstr "Critical" 3444msgid "SUN4U-8006-PJ.description" 3445msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." 3446msgid "SUN4U-8006-PJ.response" 3447msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 3448msgid "SUN4U-8006-PJ.impact" 3449msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 3450msgid "SUN4U-8006-PJ.action" 3451msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" 3452# 3453# code: SUN4U-8006-QE 3454# keys: defect.io.pci.driver fault.io.datapath fault.io.pci.bus fault.io.pci.device fault.io.tomatillo 3455# 3456msgid "SUN4U-8006-QE.type" 3457msgstr "Fault" 3458msgid "SUN4U-8006-QE.severity" 3459msgstr "Critical" 3460msgid "SUN4U-8006-QE.description" 3461msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." 3462msgid "SUN4U-8006-QE.response" 3463msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 3464msgid "SUN4U-8006-QE.impact" 3465msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 3466msgid "SUN4U-8006-QE.action" 3467msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" 3468# 3469# code: SUN4U-8006-R5 3470# keys: fault.io.hbus fault.io.pci.bus fault.io.pci.device fault.io.tomatillo 3471# 3472msgid "SUN4U-8006-R5.type" 3473msgstr "Fault" 3474msgid "SUN4U-8006-R5.severity" 3475msgstr "Critical" 3476msgid "SUN4U-8006-R5.description" 3477msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." 3478msgid "SUN4U-8006-R5.response" 3479msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 3480msgid "SUN4U-8006-R5.impact" 3481msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 3482msgid "SUN4U-8006-R5.action" 3483msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" 3484# 3485# code: SUN4U-8006-SS 3486# keys: defect.io.pci.driver fault.io.hbus fault.io.pci.bus fault.io.pci.device fault.io.tomatillo 3487# 3488msgid "SUN4U-8006-SS.type" 3489msgstr "Fault" 3490msgid "SUN4U-8006-SS.severity" 3491msgstr "Critical" 3492msgid "SUN4U-8006-SS.description" 3493msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." 3494msgid "SUN4U-8006-SS.response" 3495msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 3496msgid "SUN4U-8006-SS.impact" 3497msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 3498msgid "SUN4U-8006-SS.action" 3499msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" 3500# 3501# code: SUN4U-8006-TA 3502# keys: fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.pci.device fault.io.tomatillo 3503# 3504msgid "SUN4U-8006-TA.type" 3505msgstr "Fault" 3506msgid "SUN4U-8006-TA.severity" 3507msgstr "Critical" 3508msgid "SUN4U-8006-TA.description" 3509msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." 3510msgid "SUN4U-8006-TA.response" 3511msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 3512msgid "SUN4U-8006-TA.impact" 3513msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 3514msgid "SUN4U-8006-TA.action" 3515msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" 3516# 3517# code: SUN4U-8006-UP 3518# keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.pci.device fault.io.tomatillo 3519# 3520msgid "SUN4U-8006-UP.type" 3521msgstr "Fault" 3522msgid "SUN4U-8006-UP.severity" 3523msgstr "Critical" 3524msgid "SUN4U-8006-UP.description" 3525msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." 3526msgid "SUN4U-8006-UP.response" 3527msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 3528msgid "SUN4U-8006-UP.impact" 3529msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 3530msgid "SUN4U-8006-UP.action" 3531msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" 3532# 3533# code: SUN4U-8006-VD 3534# keys: fault.cpu.ultraSPARC-IIIiplus.dcache 3535# 3536msgid "SUN4U-8006-VD.type" 3537msgstr "Fault" 3538msgid "SUN4U-8006-VD.severity" 3539msgstr "Major" 3540msgid "SUN4U-8006-VD.description" 3541msgstr "The number of errors associated with a CPU has exceeded acceptable levels. Refer to %s for more information." 3542msgid "SUN4U-8006-VD.response" 3543msgstr "The fault manager will attempt to remove the affected CPU from service." 3544msgid "SUN4U-8006-VD.impact" 3545msgstr "System performance may be affected." 3546msgid "SUN4U-8006-VD.action" 3547msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>." 3548# 3549# code: SUN4U-8006-WH 3550# keys: fault.cpu.ultraSPARC-IIIiplus.icache 3551# 3552msgid "SUN4U-8006-WH.type" 3553msgstr "Fault" 3554msgid "SUN4U-8006-WH.severity" 3555msgstr "Major" 3556msgid "SUN4U-8006-WH.description" 3557msgstr "The number of errors associated with a CPU has exceeded acceptable levels. Refer to %s for more information." 3558msgid "SUN4U-8006-WH.response" 3559msgstr "The fault manager will attempt to remove the affected CPU from service." 3560msgid "SUN4U-8006-WH.impact" 3561msgstr "System performance may be affected." 3562msgid "SUN4U-8006-WH.action" 3563msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>." 3564# 3565# code: SUN4U-8006-X3 3566# keys: fault.cpu.ultraSPARC-IIIiplus.l2cachedata 3567# 3568msgid "SUN4U-8006-X3.type" 3569msgstr "Fault" 3570msgid "SUN4U-8006-X3.severity" 3571msgstr "Major" 3572msgid "SUN4U-8006-X3.description" 3573msgstr "The number of errors associated with a CPU has exceeded acceptable levels. Refer to %s for more information." 3574msgid "SUN4U-8006-X3.response" 3575msgstr "The fault manager will attempt to remove the affected CPU from service." 3576msgid "SUN4U-8006-X3.impact" 3577msgstr "System performance may be affected." 3578msgid "SUN4U-8006-X3.action" 3579msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>." 3580# 3581# code: SUN4U-8006-YY 3582# keys: fault.cpu.ultraSPARC-IIIiplus.l2cachetag 3583# 3584msgid "SUN4U-8006-YY.type" 3585msgstr "Fault" 3586msgid "SUN4U-8006-YY.severity" 3587msgstr "Major" 3588msgid "SUN4U-8006-YY.description" 3589msgstr "The number of errors associated with a CPU has exceeded acceptable levels. Refer to %s for more information." 3590msgid "SUN4U-8006-YY.response" 3591msgstr "The fault manager will attempt to remove the affected CPU from service." 3592msgid "SUN4U-8006-YY.impact" 3593msgstr "System performance may be affected." 3594msgid "SUN4U-8006-YY.action" 3595msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>." 3596# 3597# code: SUN4U-8007-03 3598# keys: fault.cpu.ultraSPARC-IIIiplus.fpu 3599# 3600msgid "SUN4U-8007-03.type" 3601msgstr "Fault" 3602msgid "SUN4U-8007-03.severity" 3603msgstr "Major" 3604msgid "SUN4U-8007-03.description" 3605msgstr "The number of errors associated with a CPU has exceeded acceptable levels. Refer to %s for more information." 3606msgid "SUN4U-8007-03.response" 3607msgstr "The fault manager will attempt to remove the affected CPU from service." 3608msgid "SUN4U-8007-03.impact" 3609msgstr "System performance may be affected." 3610msgid "SUN4U-8007-03.action" 3611msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>." 3612# 3613# code: SUN4U-8007-1Y 3614# keys: fault.asic.cds.dp 3615# 3616msgid "SUN4U-8007-1Y.type" 3617msgstr "Fault" 3618msgid "SUN4U-8007-1Y.severity" 3619msgstr "Critical" 3620msgid "SUN4U-8007-1Y.description" 3621msgstr "A hardware problem was detected on the datapath interconnect.\n Refer to %s for more information." 3622msgid "SUN4U-8007-1Y.response" 3623msgstr "One or more CPUs may be offlined. Additionally, page retires for memory in the impacted region may be disabled.\n" 3624msgid "SUN4U-8007-1Y.impact" 3625msgstr "System performace may be affected.\n" 3626msgid "SUN4U-8007-1Y.action" 3627msgstr "Schedule a repair procedure to replace the affected component(s). The System Controller (SC) diagnostic messages have the authoritative information on the affected component(s). fmdump -v -u <EVENT-ID> can also be used, but the SC is authoritative.\n" 3628# 3629# code: SUN4U-8007-2D 3630# keys: fault.asic.dx.dp 3631# 3632msgid "SUN4U-8007-2D.type" 3633msgstr "Fault" 3634msgid "SUN4U-8007-2D.severity" 3635msgstr "Critical" 3636msgid "SUN4U-8007-2D.description" 3637msgstr "A hardware problem was detected on the datapath interconnect.\n Refer to %s for more information." 3638msgid "SUN4U-8007-2D.response" 3639msgstr "One or more CPUs may be offlined. Additionally, page retires for memory in the impacted region may be disabled.\n" 3640msgid "SUN4U-8007-2D.impact" 3641msgstr "System performace may be affected.\n" 3642msgid "SUN4U-8007-2D.action" 3643msgstr "Schedule a repair procedure to replace the affected component(s). The System Controller (SC) diagnostic messages have the authoritative information on the affected component(s). fmdump -v -u <EVENT-ID> can also be used, but the SC is authoritative.\n" 3644# 3645# code: SUN4U-8007-3H 3646# keys: fault.asic.sdi.dp 3647# 3648msgid "SUN4U-8007-3H.type" 3649msgstr "Fault" 3650msgid "SUN4U-8007-3H.severity" 3651msgstr "Critical" 3652msgid "SUN4U-8007-3H.description" 3653msgstr "A hardware problem was detected on the datapath interconnect.\n Refer to %s for more information." 3654msgid "SUN4U-8007-3H.response" 3655msgstr "One or more CPUs may be offlined. Additionally, page retires for memory in the impacted region may be disabled.\n" 3656msgid "SUN4U-8007-3H.impact" 3657msgstr "System performace may be affected.\n" 3658msgid "SUN4U-8007-3H.action" 3659msgstr "Schedule a repair procedure to replace the affected component(s). The System Controller (SC) diagnostic messages have the authoritative information on the affected component(s). fmdump -v -u <EVENT-ID> can also be used, but the SC is authoritative.\n" 3660# 3661# code: SUN4U-8007-4A 3662# keys: fault.asic.cp.dp 3663# 3664msgid "SUN4U-8007-4A.type" 3665msgstr "Fault" 3666msgid "SUN4U-8007-4A.severity" 3667msgstr "Critical" 3668msgid "SUN4U-8007-4A.description" 3669msgstr "A hardware problem was detected on the datapath interconnect.\n Refer to %s for more information." 3670msgid "SUN4U-8007-4A.response" 3671msgstr "One or more CPUs may be offlined. Additionally, page retires for memory in the impacted region may be disabled.\n" 3672msgid "SUN4U-8007-4A.impact" 3673msgstr "System performace may be affected.\n" 3674msgid "SUN4U-8007-4A.action" 3675msgstr "Schedule a repair procedure to replace the affected component(s). The System Controller (SC) diagnostic messages have the authoritative information on the affected component(s). fmdump -v -u <EVENT-ID> can also be used, but the SC is authoritative.\n" 3676# 3677# code: SUN4U-8007-5P 3678# keys: fault.asic.rp.dp 3679# 3680msgid "SUN4U-8007-5P.type" 3681msgstr "Fault" 3682msgid "SUN4U-8007-5P.severity" 3683msgstr "Critical" 3684msgid "SUN4U-8007-5P.description" 3685msgstr "A hardware problem was detected on the datapath interconnect.\n Refer to %s for more information." 3686msgid "SUN4U-8007-5P.response" 3687msgstr "One or more CPUs may be offlined. Additionally, page retires for memory in the impacted region may be disabled.\n" 3688msgid "SUN4U-8007-5P.impact" 3689msgstr "System performace may be affected.\n" 3690msgid "SUN4U-8007-5P.action" 3691msgstr "Schedule a repair procedure to replace the affected component(s). The System Controller (SC) diagnostic messages have the authoritative information on the affected component(s). fmdump -v -u <EVENT-ID> can also be used, but the SC is authoritative.\n" 3692# 3693# code: SUN4U-8007-65 3694# keys: fault.io.oberon 3695# 3696msgid "SUN4U-8007-65.type" 3697msgstr "Fault" 3698msgid "SUN4U-8007-65.severity" 3699msgstr "Critical" 3700msgid "SUN4U-8007-65.description" 3701msgstr "Oberon PCI-Express hostbridge fault\n Refer to %s for more information." 3702msgid "SUN4U-8007-65.response" 3703msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 3704msgid "SUN4U-8007-65.impact" 3705msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 3706msgid "SUN4U-8007-65.action" 3707msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support." 3708# 3709# code: SUN4U-8007-7S 3710# keys: fault.cpu.SPARC64-VI.chip 3711# 3712msgid "SUN4U-8007-7S.type" 3713msgstr "Fault" 3714msgid "SUN4U-8007-7S.severity" 3715msgstr "Critical" 3716msgid "SUN4U-8007-7S.description" 3717msgstr "The number of errors associated with this CHIP has exceeded acceptable levels.\nRefer to %s for more information.\n Refer to %s for more information." 3718msgid "SUN4U-8007-7S.response" 3719msgstr "An attempt will be made to remove the affected CHIP from service.\n" 3720msgid "SUN4U-8007-7S.impact" 3721msgstr "The system will not be functioning at the same performance level with the CHIP removal.\n" 3722msgid "SUN4U-8007-7S.action" 3723msgstr "Schedule a repair procedure to replace the affected CHIP. Use fmdump -v -u\n to identify the smallest CPU/Strand ID of the affected CORE on this\nCHIP.\n" 3724# 3725# code: SUN4U-8007-8J 3726# keys: fault.cpu.SPARC64-VI.core 3727# 3728msgid "SUN4U-8007-8J.type" 3729msgstr "Fault" 3730msgid "SUN4U-8007-8J.severity" 3731msgstr "Critical" 3732msgid "SUN4U-8007-8J.description" 3733msgstr "The number of errors associated with this CHIP has exceeded acceptable levels.\nRefer to %s for more information.\n Refer to %s for more information." 3734msgid "SUN4U-8007-8J.response" 3735msgstr "An attempt will be made to remove the affected CORE from service.\n" 3736msgid "SUN4U-8007-8J.impact" 3737msgstr "The system will not be functioning at the same performance level with the CORE removal.\n" 3738msgid "SUN4U-8007-8J.action" 3739msgstr "Schedule a repair procedure to replace the affected CORE. Use fmdump -v -u\n to identify the smallest CPU/Strand ID of the affected CORE on this\nCORE.\n" 3740# 3741# code: SUN4U-8007-9E 3742# keys: fault.cpu.SPARC64-VI.strand 3743# 3744msgid "SUN4U-8007-9E.type" 3745msgstr "Fault" 3746msgid "SUN4U-8007-9E.severity" 3747msgstr "Critical" 3748msgid "SUN4U-8007-9E.description" 3749msgstr "The number of errors associated with this STRAND has exceeded acceptable levels.\nRefer to %s for more information.\n Refer to %s for more information." 3750msgid "SUN4U-8007-9E.response" 3751msgstr "An attempt will be made to remove the affected STRAND from service.\n" 3752msgid "SUN4U-8007-9E.impact" 3753msgstr "The system will not be functioning at the same performance level with the STRAND removal.\n" 3754msgid "SUN4U-8007-9E.action" 3755msgstr "Schedule a repair procedure to replace the affected STRAND. Use fmdump -v -u\n to identify the smallest CPU/Strand ID of the affected CORE on this\nSTRAND.\n" 3756