1# 2# Copyright 2006 Sun Microsystems, Inc. All rights reserved. 3# Use is subject to license terms. 4# 5# CDDL HEADER START 6# 7# The contents of this file are subject to the terms of the 8# Common Development and Distribution License (the "License"). 9# You may not use this file except in compliance with the License. 10# 11# You can obtain a copy of the license at usr/src/OPENSOLARIS.LICENSE 12# or http://www.opensolaris.org/os/licensing. 13# See the License for the specific language governing permissions 14# and limitations under the License. 15# 16# When distributing Covered Code, include this CDDL HEADER in each 17# file and include the License file at usr/src/OPENSOLARIS.LICENSE. 18# If applicable, add the following below this CDDL HEADER, with the 19# fields enclosed by brackets "[]" replaced with your own identifying 20# information: Portions Copyright [yyyy] [name of copyright owner] 21# 22# CDDL HEADER END 23# 24#ident "%Z%%M% %I% %E% SMI" 25# 26# DO NOT EDIT -- this file is generated by the Event Registry. 27# 28# 29# code: SUN4-8000-0Y 30# keys: fault.io.fire.asic 31# 32msgid "SUN4-8000-0Y.type" 33msgstr "Fault" 34msgid "SUN4-8000-0Y.severity" 35msgstr "Critical" 36msgid "SUN4-8000-0Y.description" 37msgstr "\nA problem was detected in the PCI-Express subsystem.\n Refer to %s for more information." 38msgid "SUN4-8000-0Y.response" 39msgstr "This fault does not have an automated response agent and thus requires interaction \nfrom the user and/or Sun Services." 40msgid "SUN4-8000-0Y.impact" 41msgstr "Loss of services provided by the device instances associated with this fault" 42msgid "SUN4-8000-0Y.action" 43msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support. \n\nIf this message occurs on a Sun Fire T2000 also refer to the NOTE\nat the end of the Details section below.\n" 44# 45# code: SUN4-8000-13 46# keys: fault.io.ebus 47# 48msgid "SUN4-8000-13.type" 49msgstr "Fault" 50msgid "SUN4-8000-13.severity" 51msgstr "Critical" 52msgid "SUN4-8000-13.description" 53msgstr "A problem was detected in the Ebus. Refer to %s for more information." 54msgid "SUN4-8000-13.response" 55msgstr "This fault does not have an automated response agent and thus requires interaction \nfrom the user and/or Sun Services." 56msgid "SUN4-8000-13.impact" 57msgstr "Loss of services provided by the device instances associated with this fault" 58msgid "SUN4-8000-13.action" 59msgstr "\nUse fmdump -v -u EVENT_ID and fmdump -eV -u \nEVENT_ID to collect information to help Sun Service personnel \nidentify the device in need of repair. Schedule a repair procedure to replace \nthe affected device.\n" 60# 61# code: SUN4-8000-2H 62# keys: fault.io.datapath 63# 64msgid "SUN4-8000-2H.type" 65msgstr "Fault" 66msgid "SUN4-8000-2H.severity" 67msgstr "Critical" 68msgid "SUN4-8000-2H.description" 69msgstr "This is an unexpected diagnosis. Please contact Sun support for details. Refer to %s for more information." 70msgid "SUN4-8000-2H.response" 71msgstr "None" 72msgid "SUN4-8000-2H.impact" 73msgstr "None" 74msgid "SUN4-8000-2H.action" 75msgstr "None" 76# 77# code: SUN4-8000-3D 78# keys: fault.io.hbus 79# 80msgid "SUN4-8000-3D.type" 81msgstr "Fault" 82msgid "SUN4-8000-3D.severity" 83msgstr "Critical" 84msgid "SUN4-8000-3D.description" 85msgstr "\nA problem was detected in a system core bus.\n Refer to %s for more information." 86msgid "SUN4-8000-3D.response" 87msgstr "This fault does not have an automated response agent and thus requires interaction \nfrom the user and/or Sun Services." 88msgid "SUN4-8000-3D.impact" 89msgstr "Loss of services provided by the device instances associated with this fault" 90msgid "SUN4-8000-3D.action" 91msgstr "\nUse fmdump -v -u EVENT_ID and fmdump -eV -u\nEVENT_ID to collect information to \nhelp Sun Service personnel identify the device in need of repair. Schedule \na repair procedure to replace the affected device.\n" 92# 93# code: SUN4-8000-4P 94# keys: fault.io.fire.pciex.device 95# 96msgid "SUN4-8000-4P.type" 97msgstr "Fault" 98msgid "SUN4-8000-4P.severity" 99msgstr "Critical" 100msgid "SUN4-8000-4P.description" 101msgstr "\nA problem was detected in the PCI-Express subsystem.\n Refer to %s for more information." 102msgid "SUN4-8000-4P.response" 103msgstr "This fault does not have an automated response agent and thus requires interaction \nfrom the user and/or Sun Services." 104msgid "SUN4-8000-4P.impact" 105msgstr "Loss of services provided by the device instances associated with this fault" 106msgid "SUN4-8000-4P.action" 107msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support. \n\nIf this message occurs on a Sun Fire T2000 also refer to the NOTE\nat the end of the Details section below." 108# 109# code: SUN4-8000-5A 110# keys: defect.io.fire.pciex.driver 111# 112msgid "SUN4-8000-5A.type" 113msgstr "Defect" 114msgid "SUN4-8000-5A.severity" 115msgstr "Critical" 116msgid "SUN4-8000-5A.description" 117msgstr "\nA problem was detected in the PCI-Express subsystem software.\n Refer to %s for more information." 118msgid "SUN4-8000-5A.response" 119msgstr "This fault does not have an automated response agent and thus requires interaction \nfrom the user and/or Sun Services." 120msgid "SUN4-8000-5A.impact" 121msgstr "Loss of services provided by the device instances associated with\nthis problem" 122msgid "SUN4-8000-5A.action" 123msgstr "Ensure latest driver and patch are installed. Use fmdump -v -u <EVENT_ID> to identify the module/package, or contact Sun for support." 124# 125# code: SUN4-8000-6S 126# keys: fault.io.datapath fault.io.fire.asic 127# 128msgid "SUN4-8000-6S.type" 129msgstr "Fault" 130msgid "SUN4-8000-6S.severity" 131msgstr "Critical" 132msgid "SUN4-8000-6S.description" 133msgstr "This is an unexpected diagnosis. Please contact Sun support for details. Refer to %s for more information." 134msgid "SUN4-8000-6S.response" 135msgstr "None" 136msgid "SUN4-8000-6S.impact" 137msgstr "None" 138msgid "SUN4-8000-6S.action" 139msgstr "None" 140# 141# code: SUN4-8000-75 142# keys: fault.io.fire.asic fault.io.fire.pciex.device 143# 144msgid "SUN4-8000-75.type" 145msgstr "Fault" 146msgid "SUN4-8000-75.severity" 147msgstr "Critical" 148msgid "SUN4-8000-75.description" 149msgstr "\nA problem was detected in the PCI-Express subsystem.\n Refer to %s for more information." 150msgid "SUN4-8000-75.response" 151msgstr "This fault does not have an automated response agent and thus requires interaction \nfrom the user and/or Sun Services." 152msgid "SUN4-8000-75.impact" 153msgstr "Loss of services provided by the device instances associated with this fault" 154msgid "SUN4-8000-75.action" 155msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support. \n\nIf this message occurs on a Sun Fire T2000 also refer to the NOTE\nat the end of the Details section below.\n" 156# 157# code: SUN4-8000-8E 158# keys: defect.io.fire.pci.driver defect.io.fire.pciex.driver 159# 160msgid "SUN4-8000-8E.type" 161msgstr "Defect" 162msgid "SUN4-8000-8E.severity" 163msgstr "Critical" 164msgid "SUN4-8000-8E.description" 165msgstr "\nA problem was detected in the PCI-Express subsystem software. Refer to %s for more information." 166msgid "SUN4-8000-8E.response" 167msgstr "This fault does not have an automated response agent and thus requires interaction \nfrom the user and/or Sun Services." 168msgid "SUN4-8000-8E.impact" 169msgstr "Loss of services provided by the device instances associated with this problem" 170msgid "SUN4-8000-8E.action" 171msgstr "Ensure latest driver and patch are installed. Use fmdump -v -u <EVENT_ID> to identify the module/package, or contact Sun for support." 172# 173# code: SUN4-8000-9J 174# keys: fault.io.fire.pci.device fault.io.fire.pciex.device 175# 176msgid "SUN4-8000-9J.type" 177msgstr "Fault" 178msgid "SUN4-8000-9J.severity" 179msgstr "Critical" 180msgid "SUN4-8000-9J.description" 181msgstr "This is an unexpected diagnosis. Please contact Sun support for details. Refer to %s for more information." 182msgid "SUN4-8000-9J.response" 183msgstr "None" 184msgid "SUN4-8000-9J.impact" 185msgstr "None" 186msgid "SUN4-8000-9J.action" 187msgstr "None" 188# 189# code: SUN4-8000-A2 190# keys: fault.io.fire.pci.device 191# 192msgid "SUN4-8000-A2.type" 193msgstr "Fault" 194msgid "SUN4-8000-A2.severity" 195msgstr "Critical" 196msgid "SUN4-8000-A2.description" 197msgstr "\nA problem was detected in the PCI subsystem.\n Refer to %s for more information." 198msgid "SUN4-8000-A2.response" 199msgstr "This fault does not have an automated response agent and thus requires interaction \nfrom the user and/or Sun Services." 200msgid "SUN4-8000-A2.impact" 201msgstr "Loss of services provided by the device instances associated with this fault" 202msgid "SUN4-8000-A2.action" 203msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" 204# 205# code: SUN4-8000-CX 206# keys: defect.io.fire.pciex.driver fault.io.datapath fault.io.fire.asic 207# 208msgid "SUN4-8000-CX.type" 209msgstr "Fault" 210msgid "SUN4-8000-CX.severity" 211msgstr "Critical" 212msgid "SUN4-8000-CX.description" 213msgstr "This is an unexpected diagnosis. Please contact Sun support for details. Refer to %s for more information." 214msgid "SUN4-8000-CX.response" 215msgstr "None" 216msgid "SUN4-8000-CX.impact" 217msgstr "None" 218msgid "SUN4-8000-CX.action" 219msgstr "None" 220# 221# code: SUN4-8000-D4 222# keys: fault.io.fire.asic fault.io.fire.pci.device fault.io.fire.pciex.device 223# 224msgid "SUN4-8000-D4.type" 225msgstr "Fault" 226msgid "SUN4-8000-D4.severity" 227msgstr "Critical" 228msgid "SUN4-8000-D4.description" 229msgstr "A problem has been detected in the PCI/PCI-Express subsystem. Refer to %s for more information." 230msgid "SUN4-8000-D4.response" 231msgstr "This fault does not have an automated response agent and thus requires interaction \nfrom the user and/or Sun Services." 232msgid "SUN4-8000-D4.impact" 233msgstr "Loss of services provided by the device instances associated with this fault" 234msgid "SUN4-8000-D4.action" 235msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support. \n\nIf this message occurs on a Sun Fire T2000 also refer to the NOTE\nat the end of the Details section below.\n" 236# 237# code: SUN4-8000-ER 238# keys: fault.io.fire.asic fault.io.fire.pci.device 239# 240msgid "SUN4-8000-ER.type" 241msgstr "Fault" 242msgid "SUN4-8000-ER.severity" 243msgstr "Critical" 244msgid "SUN4-8000-ER.description" 245msgstr "A problem has been detected in the PCI/PCI-Express subsystem. Refer to %s for more information." 246msgid "SUN4-8000-ER.response" 247msgstr "This fault does not have an automated response agent and thus requires interaction \nfrom the user and/or Sun Services." 248msgid "SUN4-8000-ER.impact" 249msgstr "Loss of services provided by the device instances associated with this fault" 250msgid "SUN4-8000-ER.action" 251msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support. \n\nIf this message occurs on a Sun Fire T2000 also refer to the NOTE\nat the end of the Details section below.\n" 252# 253# code: SUN4-8000-FC 254# keys: fault.io.fire.hbus 255# 256msgid "SUN4-8000-FC.type" 257msgstr "Fault" 258msgid "SUN4-8000-FC.severity" 259msgstr "Major" 260msgid "SUN4-8000-FC.description" 261msgstr "\nA problem was detected in a system core bus.\n Refer to %s for more information." 262msgid "SUN4-8000-FC.response" 263msgstr "This fault does not have an automated response agent and thus requires interaction \nfrom the user and/or Sun Services." 264msgid "SUN4-8000-FC.impact" 265msgstr "Loss of services provided by the device instances associated with this fault" 266msgid "SUN4-8000-FC.action" 267msgstr "\nUse fmdump -v -u EVENT_ID and fmdump -eV -u\nEVENT_ID to collect information to \nhelp Sun Service personnel identify the device in need of repair. Schedule \na repair procedure to replace the affected device.\n" 268# 269# code: SUN4-8000-GQ 270# keys: fault.io.fire.datapath fault.io.fire.hbus 271# 272msgid "SUN4-8000-GQ.type" 273msgstr "Fault" 274msgid "SUN4-8000-GQ.severity" 275msgstr "Critical" 276msgid "SUN4-8000-GQ.description" 277msgstr "Fault in either the PCIe asic's internal hostbus or connector between IO and CPU Board\n Refer to %s for more information." 278msgid "SUN4-8000-GQ.response" 279msgstr "One or more device instances may be disabled\n" 280msgid "SUN4-8000-GQ.impact" 281msgstr "Loss of services provided by the device\ninstances associated with this fault\n" 282msgid "SUN4-8000-GQ.action" 283msgstr "Schedule a repair procedure to replace the affected\ndevice if necessary, or contact Sun for support.\n" 284