xref: /titanic_41/usr/src/cmd/fm/dicts/STORAGE.po (revision 5010b7f7d31dbab7bc89cb216aeb080b56ed2e5d)
1#
2# Copyright (c) 2010, Oracle and/or its affiliates. All rights reserved.
3#
4# CDDL HEADER START
5#
6# The contents of this file are subject to the terms of the
7# Common Development and Distribution License (the "License").
8# You may not use this file except in compliance with the License.
9#
10# You can obtain a copy of the license at usr/src/OPENSOLARIS.LICENSE
11# or http://www.opensolaris.org/os/licensing.
12# See the License for the specific language governing permissions
13# and limitations under the License.
14#
15# When distributing Covered Code, include this CDDL HEADER in each
16# file and include the License file at usr/src/OPENSOLARIS.LICENSE.
17# If applicable, add the following below this CDDL HEADER, with the
18# fields enclosed by brackets "[]" replaced with your own identifying
19# information: Portions Copyright [yyyy] [name of copyright owner]
20#
21# CDDL HEADER END
22#
23
24# DO NOT EDIT -- this file is generated by the Event Registry.
25#
26#
27# code: STORAGE-8000-1Q
28# keys: fault.config.fan-fail
29#
30msgid "STORAGE-8000-1Q.type"
31msgstr "Fault"
32msgid "STORAGE-8000-1Q.severity"
33msgstr "Critical"
34msgid "STORAGE-8000-1Q.description"
35msgstr "The minimum number of required chassis fans '%<fault-list[0].resource.hc-specific.min-required>' were not detected. The missing devices are '%<fault-list[0].resource.hc-specific.devices>'."
36msgid "STORAGE-8000-1Q.response"
37msgstr "The service required LED on the chassis will be illuminated."
38msgid "STORAGE-8000-1Q.impact"
39msgstr "The SAS fabric is down, and user data storage is unavailable until the configuration problem is resolved."
40msgid "STORAGE-8000-1Q.action"
41msgstr "Check that the minimum required number of fans are configured."
42#
43# code: STORAGE-8000-24
44# keys: fault.config.fantray-fail
45#
46msgid "STORAGE-8000-24.type"
47msgstr "Fault"
48msgid "STORAGE-8000-24.severity"
49msgstr "Critical"
50msgid "STORAGE-8000-24.description"
51msgstr "The minimum number of required chassis fan trays '%<fault-list[0].resource.hc-specific.min-required>' were not detected. The missing devices are '%<fault-list[0].resource.hc-specific.devices>'."
52msgid "STORAGE-8000-24.response"
53msgstr "The service required LED on the chassis will be illuminated."
54msgid "STORAGE-8000-24.impact"
55msgstr "The SAS fabric is down, and user data storage is unavailable until the configuration problem is resolved."
56msgid "STORAGE-8000-24.action"
57msgstr "Check that the minimum required number of fan trays are configured."
58#
59# code: STORAGE-8000-3R
60# keys: fault.config.psu-fail
61#
62msgid "STORAGE-8000-3R.type"
63msgstr "Fault"
64msgid "STORAGE-8000-3R.severity"
65msgstr "Critical"
66msgid "STORAGE-8000-3R.description"
67msgstr "The minimum number of required chassis power supplies '%<fault-list[0].resource.hc-specific.min-required>' were not detected. The missing devices are '%<fault-list[0].resource.hc-specific.devices>'."
68msgid "STORAGE-8000-3R.response"
69msgstr "The service required LED on the chassis will be illuminated."
70msgid "STORAGE-8000-3R.impact"
71msgstr "The SAS fabric is down, and user data storage is unavailable until the configuration problem is resolved."
72msgid "STORAGE-8000-3R.action"
73msgstr "Check that the minimum required number of power supplies are configured."
74#
75# code: STORAGE-8000-42
76# keys: fault.device.controller.fail
77#
78msgid "STORAGE-8000-42.type"
79msgstr "Fault"
80msgid "STORAGE-8000-42.severity"
81msgstr "Major"
82msgid "STORAGE-8000-42.description"
83msgstr "Controller card '%<fault-list[0].location>' is not functioning correctly."
84msgid "STORAGE-8000-42.response"
85msgstr "The service required LED on the chassis will be illuminated."
86msgid "STORAGE-8000-42.impact"
87msgstr "The SAS fabric may be in a degraded state."
88msgid "STORAGE-8000-42.action"
89msgstr "Refer to the Maintenance page in the Sun ZFS Storage UI to identify the failed component. If a repair is required, the repair instructions are located in the help section of the Sun ZFS Storage UI."
90#
91# code: STORAGE-8000-5X
92# keys: fault.device.ethernet.fail
93#
94msgid "STORAGE-8000-5X.type"
95msgstr "Fault"
96msgid "STORAGE-8000-5X.severity"
97msgstr "Major"
98msgid "STORAGE-8000-5X.description"
99msgstr "An out-of-band management interface failure has occurred on '%<fault-list[0].location>'."
100msgid "STORAGE-8000-5X.response"
101msgstr "The service required LED on the chassis will be illuminated."
102msgid "STORAGE-8000-5X.impact"
103msgstr "The SAS fabric may be in a degraded state. User data storage is still available."
104msgid "STORAGE-8000-5X.action"
105msgstr "Refer to the Maintenance page in the Sun ZFS Storage UI to identify the failed component. If a repair is required, the repair instructions are located in the help section of the Sun ZFS Storage UI."
106#
107# code: STORAGE-8000-6E
108# keys: fault.device.fan.fail
109#
110msgid "STORAGE-8000-6E.type"
111msgstr "Fault"
112msgid "STORAGE-8000-6E.severity"
113msgstr "Major"
114msgid "STORAGE-8000-6E.description"
115msgstr "A fan on '%<fault-list[0].location>' is not functioning correctly."
116msgid "STORAGE-8000-6E.response"
117msgstr "The service required LED on the chassis will be illuminated."
118msgid "STORAGE-8000-6E.impact"
119msgstr "The chassis may be getting inadequate cooling. If the problem persists, components may overheat and the chassis may shutdown."
120msgid "STORAGE-8000-6E.action"
121msgstr "Refer to the Maintenance page in the Sun ZFS Storage UI to identify the failed component. If a repair is required, the repair instructions are located in the help section of the Sun ZFS Storage UI."
122#
123# code: STORAGE-8000-7J
124# keys: fault.device.psu.fail
125#
126msgid "STORAGE-8000-7J.type"
127msgstr "Fault"
128msgid "STORAGE-8000-7J.severity"
129msgstr "Major"
130msgid "STORAGE-8000-7J.description"
131msgstr "Power supply '%<fault-list[0].location>' is not functioning correctly."
132msgid "STORAGE-8000-7J.response"
133msgstr "The service required LED on the chassis will be illuminated."
134msgid "STORAGE-8000-7J.impact"
135msgstr "The chassis may not be getting adequate power. Subsequent loss of power supplies may cause the chassis to shutdown."
136msgid "STORAGE-8000-7J.action"
137msgstr "Refer to the Maintenance page in the Sun ZFS Storage UI to identify the failed component. If a repair is required, the repair instructions are located in the help section of the Sun ZFS Storage UI."
138#
139# code: STORAGE-8000-8S
140# keys: fault.device.sas-expander.fail
141#
142msgid "STORAGE-8000-8S.type"
143msgstr "Fault"
144msgid "STORAGE-8000-8S.severity"
145msgstr "Major"
146msgid "STORAGE-8000-8S.description"
147msgstr "A SAS expander on '%<fault-list[0].location>' is not functioning correctly."
148msgid "STORAGE-8000-8S.response"
149msgstr "The service required LED on the chassis will be illuminated."
150msgid "STORAGE-8000-8S.impact"
151msgstr "The SAS fabric is in a degraded state. User data storage may be degraded or unavailable."
152msgid "STORAGE-8000-8S.action"
153msgstr "Refer to the Maintenance page in the Sun ZFS Storage UI to identify the failed component. If a repair is required, the repair instructions are located in the help section of the Sun ZFS Storage UI."
154#
155# code: STORAGE-8000-95
156# keys: fault.device.unusable-chassis-id
157#
158msgid "STORAGE-8000-95.type"
159msgstr "Fault"
160msgid "STORAGE-8000-95.severity"
161msgstr "Critical"
162msgid "STORAGE-8000-95.description"
163msgstr "The chassis ID was determined to be unusable."
164msgid "STORAGE-8000-95.response"
165msgstr "The service required LED on the chassis will be illuminated."
166msgid "STORAGE-8000-95.impact"
167msgstr "The SAS fabric is down, and user data storage is unavailable."
168msgid "STORAGE-8000-95.action"
169msgstr "Refer to the Maintenance page in the Sun ZFS Storage UI to identify the failed component. If a repair is required, the repair instructions are located in the help section of the Sun ZFS Storage UI."
170#
171# code: STORAGE-8000-AP
172# keys: fault.io.i2c.fail
173#
174msgid "STORAGE-8000-AP.type"
175msgstr "Fault"
176msgid "STORAGE-8000-AP.severity"
177msgstr "Critical"
178msgid "STORAGE-8000-AP.description"
179msgstr "An I2C bus on '%<fault-list[0].location>' is not functioning correctly."
180msgid "STORAGE-8000-AP.response"
181msgstr "The service required LED on the chassis will be illuminated."
182msgid "STORAGE-8000-AP.impact"
183msgstr "The system is in an unknown state."
184msgid "STORAGE-8000-AP.action"
185msgstr "Refer to the Maintenance page in the Sun ZFS Storage UI to identify the failed component. If a repair is required, the repair instructions are located in the help section of the Sun ZFS Storage UI."
186#
187# code: STORAGE-8000-CA
188# keys: fault.io.sas.log.fatal
189#
190msgid "STORAGE-8000-CA.type"
191msgstr "Fault"
192msgid "STORAGE-8000-CA.severity"
193msgstr "Critical"
194msgid "STORAGE-8000-CA.description"
195msgstr "A fatal error has been detected by a SAS expander on '%<fault-list[0].location>' requiring it to reset."
196msgid "STORAGE-8000-CA.response"
197msgstr "The service required LED on the chassis will be illuminated."
198msgid "STORAGE-8000-CA.impact"
199msgstr "The SAS expander is not functioning correctly. The SAS fabric will be in a degraded state while the expander resets. Downstream devices may be inaccessible."
200msgid "STORAGE-8000-CA.action"
201msgstr "Refer to the Maintenance page in the Sun ZFS Storage UI to identify the failed component. If a repair is required, the repair instructions are located in the help section of the Sun ZFS Storage UI."
202#
203# code: STORAGE-8000-DH
204# keys: fault.io.sas.log.non-fatal
205#
206msgid "STORAGE-8000-DH.type"
207msgstr "Fault"
208msgid "STORAGE-8000-DH.severity"
209msgstr "Major"
210msgid "STORAGE-8000-DH.description"
211msgstr "A non-fatal error has been detected by a SAS expander on '%<fault-list[0].location>'."
212msgid "STORAGE-8000-DH.response"
213msgstr "The service required LED on the chassis will be illuminated."
214msgid "STORAGE-8000-DH.impact"
215msgstr "The SAS expander may not be functioning correctly. The SAS fabric may be in a degraded state. Downstream devices may be inaccessible."
216msgid "STORAGE-8000-DH.action"
217msgstr "Refer to the Maintenance page in the Sun ZFS Storage UI to identify the failed component. If a repair is required, the repair instructions are located in the help section of the Sun ZFS Storage UI."
218#
219# code: STORAGE-8000-ED
220# keys: fault.power.ext-fail
221#
222msgid "STORAGE-8000-ED.type"
223msgstr "Fault"
224msgid "STORAGE-8000-ED.severity"
225msgstr "Major"
226msgid "STORAGE-8000-ED.description"
227msgstr "A power failure external to the chassis has occurred."
228msgid "STORAGE-8000-ED.response"
229msgstr "None."
230msgid "STORAGE-8000-ED.impact"
231msgstr "The chassis may not be getting adequate power. Subsequent loss of power supplies may cause the chassis to shutdown."
232msgid "STORAGE-8000-ED.action"
233msgstr "Check that external AC power is available and that all the power cords are plugged into the chassis power supplies."
234#
235# code: STORAGE-8000-FY
236# keys: fault.power.fail
237#
238msgid "STORAGE-8000-FY.type"
239msgstr "Fault"
240msgid "STORAGE-8000-FY.severity"
241msgstr "Major"
242msgid "STORAGE-8000-FY.description"
243msgstr "A power failure has occurred on '%<fault-list[0].location>'."
244msgid "STORAGE-8000-FY.response"
245msgstr "The service required LED on the chassis will be illuminated."
246msgid "STORAGE-8000-FY.impact"
247msgstr "A device in the chassis may be getting inadequate power. Subsequent loss of the device may force the chassis to shutdown."
248msgid "STORAGE-8000-FY.action"
249msgstr "Refer to the Maintenance page in the Sun ZFS Storage UI to identify the failed component. If a repair is required, the repair instructions are located in the help section of the Sun ZFS Storage UI."
250#
251# code: STORAGE-8000-G3
252# keys: fault.sensor.read-fail
253#
254msgid "STORAGE-8000-G3.type"
255msgstr "Fault"
256msgid "STORAGE-8000-G3.severity"
257msgstr "Major"
258msgid "STORAGE-8000-G3.description"
259msgstr "An attempt to read a sensor on '%<fault-list[0].location>' failed."
260msgid "STORAGE-8000-G3.response"
261msgstr "The service required LED on the chassis will be illuminated."
262msgid "STORAGE-8000-G3.impact"
263msgstr "Data from the affected sensor will be unavailable. Data from other sensors may be used instead if available."
264msgid "STORAGE-8000-G3.action"
265msgstr "Refer to the Maintenance page in the Sun ZFS Storage UI to identify the failed component. If a repair is required, the repair instructions are located in the help section of the Sun ZFS Storage UI."
266#
267# code: STORAGE-8000-HR
268# keys: fault.sp.fail
269#
270msgid "STORAGE-8000-HR.type"
271msgstr "Fault"
272msgid "STORAGE-8000-HR.severity"
273msgstr "Critical"
274msgid "STORAGE-8000-HR.description"
275msgstr "A Service Processor on '%<fault-list[0].location>' is not functioning correctly."
276msgid "STORAGE-8000-HR.response"
277msgstr "The service required LED on the chassis will be illuminated."
278msgid "STORAGE-8000-HR.impact"
279msgstr "The SAS fabric may be in a degraded state."
280msgid "STORAGE-8000-HR.action"
281msgstr "Refer to the Maintenance page in the Sun ZFS Storage UI to identify the failed component. If a repair is required, the repair instructions are located in the help section of the Sun ZFS Storage UI."
282#
283# code: STORAGE-8000-J4
284# keys: fault.sp.unavailable
285#
286msgid "STORAGE-8000-J4.type"
287msgstr "Fault"
288msgid "STORAGE-8000-J4.severity"
289msgstr "Major"
290msgid "STORAGE-8000-J4.description"
291msgstr "A Service Processor has detected that its peer is unavailable."
292msgid "STORAGE-8000-J4.response"
293msgstr "The service required LED on the chassis will be illuminated."
294msgid "STORAGE-8000-J4.impact"
295msgstr "IMP_FAB_MB_DEG"
296msgid "STORAGE-8000-J4.action"
297msgstr "Refer to the Maintenance page in the Sun ZFS Storage UI to identify the failed component. If a repair is required, the repair instructions are located in the help section of the Sun ZFS Storage UI."
298#
299# code: STORAGE-8000-KQ
300# keys: fault.sp.svc-fail
301#
302msgid "STORAGE-8000-KQ.type"
303msgstr "Fault"
304msgid "STORAGE-8000-KQ.severity"
305msgstr "Major"
306msgid "STORAGE-8000-KQ.description"
307msgstr "A Service Processor software service failure has occurred on '%<fault-list[0].location>'. The service which restarted was '%<fault-list[0].resource.hc-specific.service>'."
308msgid "STORAGE-8000-KQ.response"
309msgstr "The service required LED on the chassis will be illuminated."
310msgid "STORAGE-8000-KQ.impact"
311msgstr "The SAS fabric may be in a degraded state. User data storage is still available."
312msgid "STORAGE-8000-KQ.action"
313msgstr "Refer to the Maintenance page in the Sun ZFS Storage UI to identify the failed component. If a repair is required, the repair instructions are located in the help section of the Sun ZFS Storage UI."
314#
315# code: STORAGE-8000-LC
316# keys: fault.temp.fail
317#
318msgid "STORAGE-8000-LC.type"
319msgstr "Fault"
320msgid "STORAGE-8000-LC.severity"
321msgstr "Major"
322msgid "STORAGE-8000-LC.description"
323msgstr "Ambient temperature is outside of normal operating range."
324msgid "STORAGE-8000-LC.response"
325msgstr "The service required LED on the chassis will be illuminated."
326msgid "STORAGE-8000-LC.impact"
327msgstr "A device in the chassis may be overheating. Subsequent loss of the device may force the chassis to shutdown."
328msgid "STORAGE-8000-LC.action"