1# 2# Copyright (c) 2010, Oracle and/or its affiliates. All rights reserved. 3# 4# CDDL HEADER START 5# 6# The contents of this file are subject to the terms of the 7# Common Development and Distribution License (the "License"). 8# You may not use this file except in compliance with the License. 9# 10# You can obtain a copy of the license at usr/src/OPENSOLARIS.LICENSE 11# or http://www.opensolaris.org/os/licensing. 12# See the License for the specific language governing permissions 13# and limitations under the License. 14# 15# When distributing Covered Code, include this CDDL HEADER in each 16# file and include the License file at usr/src/OPENSOLARIS.LICENSE. 17# If applicable, add the following below this CDDL HEADER, with the 18# fields enclosed by brackets "[]" replaced with your own identifying 19# information: Portions Copyright [yyyy] [name of copyright owner] 20# 21# CDDL HEADER END 22# 23 24# DO NOT EDIT -- this file is generated by the Event Registry. 25# 26# 27# code: STORAGE-8000-1Q 28# keys: fault.config.fan-fail 29# 30msgid "STORAGE-8000-1Q.type" 31msgstr "Fault" 32msgid "STORAGE-8000-1Q.severity" 33msgstr "Critical" 34msgid "STORAGE-8000-1Q.description" 35msgstr "The minimum number of required chassis fans '%<fault-list[0].resource.hc-specific.min-required>' were not detected. The missing devices are '%<fault-list[0].resource.hc-specific.devices>'." 36msgid "STORAGE-8000-1Q.response" 37msgstr "The service required LED on the chassis will be illuminated." 38msgid "STORAGE-8000-1Q.impact" 39msgstr "The SAS fabric is down, and user data storage is unavailable until the configuration problem is resolved." 40msgid "STORAGE-8000-1Q.action" 41msgstr "Check that the minimum required number of fans are configured." 42# 43# code: STORAGE-8000-24 44# keys: fault.config.fantray-fail 45# 46msgid "STORAGE-8000-24.type" 47msgstr "Fault" 48msgid "STORAGE-8000-24.severity" 49msgstr "Critical" 50msgid "STORAGE-8000-24.description" 51msgstr "The minimum number of required chassis fan trays '%<fault-list[0].resource.hc-specific.min-required>' were not detected. The missing devices are '%<fault-list[0].resource.hc-specific.devices>'." 52msgid "STORAGE-8000-24.response" 53msgstr "The service required LED on the chassis will be illuminated." 54msgid "STORAGE-8000-24.impact" 55msgstr "The SAS fabric is down, and user data storage is unavailable until the configuration problem is resolved." 56msgid "STORAGE-8000-24.action" 57msgstr "Check that the minimum required number of fan trays are configured." 58# 59# code: STORAGE-8000-3R 60# keys: fault.config.psu-fail 61# 62msgid "STORAGE-8000-3R.type" 63msgstr "Fault" 64msgid "STORAGE-8000-3R.severity" 65msgstr "Critical" 66msgid "STORAGE-8000-3R.description" 67msgstr "The minimum number of required chassis power supplies '%<fault-list[0].resource.hc-specific.min-required>' were not detected. The missing devices are '%<fault-list[0].resource.hc-specific.devices>'." 68msgid "STORAGE-8000-3R.response" 69msgstr "The service required LED on the chassis will be illuminated." 70msgid "STORAGE-8000-3R.impact" 71msgstr "The SAS fabric is down, and user data storage is unavailable until the configuration problem is resolved." 72msgid "STORAGE-8000-3R.action" 73msgstr "Check that the minimum required number of power supplies are configured." 74# 75# code: STORAGE-8000-42 76# keys: fault.device.controller.fail 77# 78msgid "STORAGE-8000-42.type" 79msgstr "Fault" 80msgid "STORAGE-8000-42.severity" 81msgstr "Major" 82msgid "STORAGE-8000-42.description" 83msgstr "Controller card '%<fault-list[0].location>' is not functioning correctly." 84msgid "STORAGE-8000-42.response" 85msgstr "The service required LED on the chassis will be illuminated." 86msgid "STORAGE-8000-42.impact" 87msgstr "The SAS fabric may be in a degraded state." 88msgid "STORAGE-8000-42.action" 89msgstr "Refer to the Maintenance page in the Sun ZFS Storage UI to identify the failed component. If a repair is required, the repair instructions are located in the help section of the Sun ZFS Storage UI." 90# 91# code: STORAGE-8000-5X 92# keys: fault.device.ethernet.fail 93# 94msgid "STORAGE-8000-5X.type" 95msgstr "Fault" 96msgid "STORAGE-8000-5X.severity" 97msgstr "Major" 98msgid "STORAGE-8000-5X.description" 99msgstr "An out-of-band management interface failure has occurred on '%<fault-list[0].location>'." 100msgid "STORAGE-8000-5X.response" 101msgstr "The service required LED on the chassis will be illuminated." 102msgid "STORAGE-8000-5X.impact" 103msgstr "The SAS fabric may be in a degraded state. User data storage is still available." 104msgid "STORAGE-8000-5X.action" 105msgstr "Refer to the Maintenance page in the Sun ZFS Storage UI to identify the failed component. If a repair is required, the repair instructions are located in the help section of the Sun ZFS Storage UI." 106# 107# code: STORAGE-8000-6E 108# keys: fault.device.fan.fail 109# 110msgid "STORAGE-8000-6E.type" 111msgstr "Fault" 112msgid "STORAGE-8000-6E.severity" 113msgstr "Major" 114msgid "STORAGE-8000-6E.description" 115msgstr "A fan on '%<fault-list[0].location>' is not functioning correctly." 116msgid "STORAGE-8000-6E.response" 117msgstr "The service required LED on the chassis will be illuminated." 118msgid "STORAGE-8000-6E.impact" 119msgstr "The chassis may be getting inadequate cooling. If the problem persists, components may overheat and the chassis may shutdown." 120msgid "STORAGE-8000-6E.action" 121msgstr "Refer to the Maintenance page in the Sun ZFS Storage UI to identify the failed component. If a repair is required, the repair instructions are located in the help section of the Sun ZFS Storage UI." 122# 123# code: STORAGE-8000-7J 124# keys: fault.device.psu.fail 125# 126msgid "STORAGE-8000-7J.type" 127msgstr "Fault" 128msgid "STORAGE-8000-7J.severity" 129msgstr "Major" 130msgid "STORAGE-8000-7J.description" 131msgstr "Power supply '%<fault-list[0].location>' is not functioning correctly." 132msgid "STORAGE-8000-7J.response" 133msgstr "The service required LED on the chassis will be illuminated." 134msgid "STORAGE-8000-7J.impact" 135msgstr "The chassis may not be getting adequate power. Subsequent loss of power supplies may cause the chassis to shutdown." 136msgid "STORAGE-8000-7J.action" 137msgstr "Refer to the Maintenance page in the Sun ZFS Storage UI to identify the failed component. If a repair is required, the repair instructions are located in the help section of the Sun ZFS Storage UI." 138# 139# code: STORAGE-8000-8S 140# keys: fault.device.sas-expander.fail 141# 142msgid "STORAGE-8000-8S.type" 143msgstr "Fault" 144msgid "STORAGE-8000-8S.severity" 145msgstr "Major" 146msgid "STORAGE-8000-8S.description" 147msgstr "A SAS expander on '%<fault-list[0].location>' is not functioning correctly." 148msgid "STORAGE-8000-8S.response" 149msgstr "The service required LED on the chassis will be illuminated." 150msgid "STORAGE-8000-8S.impact" 151msgstr "The SAS fabric is in a degraded state. User data storage may be degraded or unavailable." 152msgid "STORAGE-8000-8S.action" 153msgstr "Refer to the Maintenance page in the Sun ZFS Storage UI to identify the failed component. If a repair is required, the repair instructions are located in the help section of the Sun ZFS Storage UI." 154# 155# code: STORAGE-8000-95 156# keys: fault.device.unusable-chassis-id 157# 158msgid "STORAGE-8000-95.type" 159msgstr "Fault" 160msgid "STORAGE-8000-95.severity" 161msgstr "Critical" 162msgid "STORAGE-8000-95.description" 163msgstr "The chassis ID was determined to be unusable." 164msgid "STORAGE-8000-95.response" 165msgstr "The service required LED on the chassis will be illuminated." 166msgid "STORAGE-8000-95.impact" 167msgstr "The SAS fabric is down, and user data storage is unavailable." 168msgid "STORAGE-8000-95.action" 169msgstr "Refer to the Maintenance page in the Sun ZFS Storage UI to identify the failed component. If a repair is required, the repair instructions are located in the help section of the Sun ZFS Storage UI." 170# 171# code: STORAGE-8000-AP 172# keys: fault.io.i2c.fail 173# 174msgid "STORAGE-8000-AP.type" 175msgstr "Fault" 176msgid "STORAGE-8000-AP.severity" 177msgstr "Critical" 178msgid "STORAGE-8000-AP.description" 179msgstr "An I2C bus on '%<fault-list[0].location>' is not functioning correctly." 180msgid "STORAGE-8000-AP.response" 181msgstr "The service required LED on the chassis will be illuminated." 182msgid "STORAGE-8000-AP.impact" 183msgstr "The system is in an unknown state." 184msgid "STORAGE-8000-AP.action" 185msgstr "Refer to the Maintenance page in the Sun ZFS Storage UI to identify the failed component. If a repair is required, the repair instructions are located in the help section of the Sun ZFS Storage UI." 186# 187# code: STORAGE-8000-CA 188# keys: fault.io.sas.log.fatal 189# 190msgid "STORAGE-8000-CA.type" 191msgstr "Fault" 192msgid "STORAGE-8000-CA.severity" 193msgstr "Critical" 194msgid "STORAGE-8000-CA.description" 195msgstr "A fatal error has been detected by a SAS expander on '%<fault-list[0].location>' requiring it to reset." 196msgid "STORAGE-8000-CA.response" 197msgstr "The service required LED on the chassis will be illuminated." 198msgid "STORAGE-8000-CA.impact" 199msgstr "The SAS expander is not functioning correctly. The SAS fabric will be in a degraded state while the expander resets. Downstream devices may be inaccessible." 200msgid "STORAGE-8000-CA.action" 201msgstr "Refer to the Maintenance page in the Sun ZFS Storage UI to identify the failed component. If a repair is required, the repair instructions are located in the help section of the Sun ZFS Storage UI." 202# 203# code: STORAGE-8000-DH 204# keys: fault.io.sas.log.non-fatal 205# 206msgid "STORAGE-8000-DH.type" 207msgstr "Fault" 208msgid "STORAGE-8000-DH.severity" 209msgstr "Major" 210msgid "STORAGE-8000-DH.description" 211msgstr "A non-fatal error has been detected by a SAS expander on '%<fault-list[0].location>'." 212msgid "STORAGE-8000-DH.response" 213msgstr "The service required LED on the chassis will be illuminated." 214msgid "STORAGE-8000-DH.impact" 215msgstr "The SAS expander may not be functioning correctly. The SAS fabric may be in a degraded state. Downstream devices may be inaccessible." 216msgid "STORAGE-8000-DH.action" 217msgstr "Refer to the Maintenance page in the Sun ZFS Storage UI to identify the failed component. If a repair is required, the repair instructions are located in the help section of the Sun ZFS Storage UI." 218# 219# code: STORAGE-8000-ED 220# keys: fault.power.ext-fail 221# 222msgid "STORAGE-8000-ED.type" 223msgstr "Fault" 224msgid "STORAGE-8000-ED.severity" 225msgstr "Major" 226msgid "STORAGE-8000-ED.description" 227msgstr "A power failure external to the chassis has occurred." 228msgid "STORAGE-8000-ED.response" 229msgstr "None." 230msgid "STORAGE-8000-ED.impact" 231msgstr "The chassis may not be getting adequate power. Subsequent loss of power supplies may cause the chassis to shutdown." 232msgid "STORAGE-8000-ED.action" 233msgstr "Check that external AC power is available and that all the power cords are plugged into the chassis power supplies." 234# 235# code: STORAGE-8000-FY 236# keys: fault.power.fail 237# 238msgid "STORAGE-8000-FY.type" 239msgstr "Fault" 240msgid "STORAGE-8000-FY.severity" 241msgstr "Major" 242msgid "STORAGE-8000-FY.description" 243msgstr "A power failure has occurred on '%<fault-list[0].location>'." 244msgid "STORAGE-8000-FY.response" 245msgstr "The service required LED on the chassis will be illuminated." 246msgid "STORAGE-8000-FY.impact" 247msgstr "A device in the chassis may be getting inadequate power. Subsequent loss of the device may force the chassis to shutdown." 248msgid "STORAGE-8000-FY.action" 249msgstr "Refer to the Maintenance page in the Sun ZFS Storage UI to identify the failed component. If a repair is required, the repair instructions are located in the help section of the Sun ZFS Storage UI." 250# 251# code: STORAGE-8000-G3 252# keys: fault.sensor.read-fail 253# 254msgid "STORAGE-8000-G3.type" 255msgstr "Fault" 256msgid "STORAGE-8000-G3.severity" 257msgstr "Major" 258msgid "STORAGE-8000-G3.description" 259msgstr "An attempt to read a sensor on '%<fault-list[0].location>' failed." 260msgid "STORAGE-8000-G3.response" 261msgstr "The service required LED on the chassis will be illuminated." 262msgid "STORAGE-8000-G3.impact" 263msgstr "Data from the affected sensor will be unavailable. Data from other sensors may be used instead if available." 264msgid "STORAGE-8000-G3.action" 265msgstr "Refer to the Maintenance page in the Sun ZFS Storage UI to identify the failed component. If a repair is required, the repair instructions are located in the help section of the Sun ZFS Storage UI." 266# 267# code: STORAGE-8000-HR 268# keys: fault.sp.fail 269# 270msgid "STORAGE-8000-HR.type" 271msgstr "Fault" 272msgid "STORAGE-8000-HR.severity" 273msgstr "Critical" 274msgid "STORAGE-8000-HR.description" 275msgstr "A Service Processor on '%<fault-list[0].location>' is not functioning correctly." 276msgid "STORAGE-8000-HR.response" 277msgstr "The service required LED on the chassis will be illuminated." 278msgid "STORAGE-8000-HR.impact" 279msgstr "The SAS fabric may be in a degraded state." 280msgid "STORAGE-8000-HR.action" 281msgstr "Refer to the Maintenance page in the Sun ZFS Storage UI to identify the failed component. If a repair is required, the repair instructions are located in the help section of the Sun ZFS Storage UI." 282# 283# code: STORAGE-8000-J4 284# keys: fault.sp.unavailable 285# 286msgid "STORAGE-8000-J4.type" 287msgstr "Fault" 288msgid "STORAGE-8000-J4.severity" 289msgstr "Major" 290msgid "STORAGE-8000-J4.description" 291msgstr "A Service Processor has detected that its peer is unavailable." 292msgid "STORAGE-8000-J4.response" 293msgstr "The service required LED on the chassis will be illuminated." 294msgid "STORAGE-8000-J4.impact" 295msgstr "IMP_FAB_MB_DEG" 296msgid "STORAGE-8000-J4.action" 297msgstr "Refer to the Maintenance page in the Sun ZFS Storage UI to identify the failed component. If a repair is required, the repair instructions are located in the help section of the Sun ZFS Storage UI." 298# 299# code: STORAGE-8000-KQ 300# keys: fault.sp.svc-fail 301# 302msgid "STORAGE-8000-KQ.type" 303msgstr "Fault" 304msgid "STORAGE-8000-KQ.severity" 305msgstr "Major" 306msgid "STORAGE-8000-KQ.description" 307msgstr "A Service Processor software service failure has occurred on '%<fault-list[0].location>'. The service which restarted was '%<fault-list[0].resource.hc-specific.service>'." 308msgid "STORAGE-8000-KQ.response" 309msgstr "The service required LED on the chassis will be illuminated." 310msgid "STORAGE-8000-KQ.impact" 311msgstr "The SAS fabric may be in a degraded state. User data storage is still available." 312msgid "STORAGE-8000-KQ.action" 313msgstr "Refer to the Maintenance page in the Sun ZFS Storage UI to identify the failed component. If a repair is required, the repair instructions are located in the help section of the Sun ZFS Storage UI." 314# 315# code: STORAGE-8000-LC 316# keys: fault.temp.fail 317# 318msgid "STORAGE-8000-LC.type" 319msgstr "Fault" 320msgid "STORAGE-8000-LC.severity" 321msgstr "Major" 322msgid "STORAGE-8000-LC.description" 323msgstr "Ambient temperature is outside of normal operating range." 324msgid "STORAGE-8000-LC.response" 325msgstr "The service required LED on the chassis will be illuminated." 326msgid "STORAGE-8000-LC.impact" 327msgstr "A device in the chassis may be overheating. Subsequent loss of the device may force the chassis to shutdown." 328msgid "STORAGE-8000-LC.action" 329msgstr "Check that the ambient temperature is adequately cool, and none of the chassis air inlets are blocked." 330