1# 2# Copyright 2009 Sun Microsystems, Inc. All rights reserved. 3# Use is subject to license terms. 4# 5# CDDL HEADER START 6# 7# The contents of this file are subject to the terms of the 8# Common Development and Distribution License (the "License"). 9# You may not use this file except in compliance with the License. 10# 11# You can obtain a copy of the license at usr/src/OPENSOLARIS.LICENSE 12# or http://www.opensolaris.org/os/licensing. 13# See the License for the specific language governing permissions 14# and limitations under the License. 15# 16# When distributing Covered Code, include this CDDL HEADER in each 17# file and include the License file at usr/src/OPENSOLARIS.LICENSE. 18# If applicable, add the following below this CDDL HEADER, with the 19# fields enclosed by brackets "[]" replaced with your own identifying 20# information: Portions Copyright [yyyy] [name of copyright owner] 21# 22# CDDL HEADER END 23# 24# DO NOT EDIT -- this file is generated by the Event Registry. 25# 26# 27# code: PCIEX-8000-0A 28# keys: fault.io.pciex.device-interr 29# 30msgid "PCIEX-8000-0A.type" 31msgstr "Fault" 32msgid "PCIEX-8000-0A.severity" 33msgstr "Critical" 34msgid "PCIEX-8000-0A.description" 35msgstr "A problem was detected for a PCIEX device.\n Refer to %s for more information." 36msgid "PCIEX-8000-0A.response" 37msgstr "One or more device instances may be disabled\n" 38msgid "PCIEX-8000-0A.impact" 39msgstr "Loss of services provided by the device instances associated with this fault\n" 40msgid "PCIEX-8000-0A.action" 41msgstr "Schedule a repair procedure to replace the affected device. Use fmadm faulty to identify the device or contact Sun for support.\n" 42# 43# code: PCIEX-8000-1P 44# keys: fault.io.pciex.device-interr fault.io.pciex.device-invreq 45# 46msgid "PCIEX-8000-1P.type" 47msgstr "Fault" 48msgid "PCIEX-8000-1P.severity" 49msgstr "Major" 50msgid "PCIEX-8000-1P.description" 51msgstr "Either the transmitting device sent an invalid request or the receiving device is reporting an internal fault.\n Refer to %s for more information." 52msgid "PCIEX-8000-1P.response" 53msgstr "One or more device instances may be disabled\n" 54msgid "PCIEX-8000-1P.impact" 55msgstr "Loss of services provided by the device instances associated with this fault\n" 56msgid "PCIEX-8000-1P.action" 57msgstr "Ensure that the latest drivers and patches are installed. Otherwise schedule a repair procedure to replace the affected device(s). Use fmadm faulty to identify the devices or contact Sun for support.\n" 58# 59# code: PCIEX-8000-25 60# keys: fault.io.pciex.bus-noresp fault.io.pciex.device-noresp 61# 62msgid "PCIEX-8000-25.type" 63msgstr "Fault" 64msgid "PCIEX-8000-25.severity" 65msgstr "Critical" 66msgid "PCIEX-8000-25.description" 67msgstr "The receiving device failed to respond.\n Refer to %s for more information." 68msgid "PCIEX-8000-25.response" 69msgstr "One or more device instances may be disabled\n" 70msgid "PCIEX-8000-25.impact" 71msgstr "Loss of services provided by the device instances associated with this fault\n" 72msgid "PCIEX-8000-25.action" 73msgstr "If a plug-in card is involved check for badly-seated cards or bent pins. Otherwise schedule a repair procedure to replace the affected device(s). Use fmadm faulty to identify the devices or contact Sun for support.\n" 74# 75# code: PCIEX-8000-3S 76# keys: fault.io.pciex.bus-linkerr fault.io.pciex.device-interr 77# 78msgid "PCIEX-8000-3S.type" 79msgstr "Fault" 80msgid "PCIEX-8000-3S.severity" 81msgstr "Critical" 82msgid "PCIEX-8000-3S.description" 83msgstr "A problem has been detected on one of the specified devices or on one of the specified connecting buses.\n Refer to %s for more information." 84msgid "PCIEX-8000-3S.response" 85msgstr "One or more device instances may be disabled\n" 86msgid "PCIEX-8000-3S.impact" 87msgstr "Loss of services provided by the device instances associated with this fault\n" 88msgid "PCIEX-8000-3S.action" 89msgstr "If a plug-in card is involved check for badly-seated cards or bent pins. Otherwise schedule a repair procedure to replace the affected device(s). Use fmadm faulty to identify the devices or contact Sun for support.\n" 90# 91# code: PCIEX-8000-43 92# keys: fault.io.pci.bus-linkerr fault.io.pciex.device-interr 93# 94msgid "PCIEX-8000-43.type" 95msgstr "Fault" 96msgid "PCIEX-8000-43.severity" 97msgstr "Critical" 98msgid "PCIEX-8000-43.description" 99msgstr "A problem has been detected on one of the specified devices or on one of the specified connecting buses.\n Refer to %s for more information." 100msgid "PCIEX-8000-43.response" 101msgstr "One or more device instances may be disabled\n" 102msgid "PCIEX-8000-43.impact" 103msgstr "Loss of services provided by the device instances associated with this fault\n" 104msgid "PCIEX-8000-43.action" 105msgstr "If a plug-in card is involved check for badly-seated cards or bent pins. Otherwise schedule a repair procedure to replace the affected device. Use fmadm faulty to identify the device and bus or contact Sun for support.\n" 106# 107# code: PCIEX-8000-5Y 108# keys: fault.io.pci.device-invreq 109# 110msgid "PCIEX-8000-5Y.type" 111msgstr "Fault" 112msgid "PCIEX-8000-5Y.severity" 113msgstr "Major" 114msgid "PCIEX-8000-5Y.description" 115msgstr "The transmitting device sent an invalid request.\n Refer to %s for more information." 116msgid "PCIEX-8000-5Y.response" 117msgstr "One or more device instances may be disabled\n" 118msgid "PCIEX-8000-5Y.impact" 119msgstr "Loss of services provided by the device instances associated with this fault\n" 120msgid "PCIEX-8000-5Y.action" 121msgstr "Ensure that the latest drivers and patches are installed. Otherwise schedule a repair procedure to replace the affected device(s). Use fmadm faulty to identify the devices or contact Sun for support." 122# 123# code: PCIEX-8000-6D 124# keys: fault.io.pci.device-invreq fault.io.pciex.device-interr 125# 126msgid "PCIEX-8000-6D.type" 127msgstr "Fault" 128msgid "PCIEX-8000-6D.severity" 129msgstr "Major" 130msgid "PCIEX-8000-6D.description" 131msgstr "Either the transmitting device sent an invalid request or the receiving device is reporting an internal fault.\n Refer to %s for more information." 132msgid "PCIEX-8000-6D.response" 133msgstr "One or more device instances may be disabled\n" 134msgid "PCIEX-8000-6D.impact" 135msgstr "Loss of services provided by the device instances associated with this fault\n" 136msgid "PCIEX-8000-6D.action" 137msgstr "Ensure that the latest drivers and patches are installed. Otherwise schedule a repair procedure to replace the affected device(s). Use fmadm faulty to identify the devices or contact Sun for support.\n" 138# 139# code: PCIEX-8000-7H 140# keys: fault.io.pci.device-interr fault.io.pciex.device-invreq 141# 142msgid "PCIEX-8000-7H.type" 143msgstr "Fault" 144msgid "PCIEX-8000-7H.severity" 145msgstr "Major" 146msgid "PCIEX-8000-7H.description" 147msgstr "Either the transmitting device sent an invalid request or the receiving device is reporting an internal fault.\n Refer to %s for more information." 148msgid "PCIEX-8000-7H.response" 149msgstr "One or more device instances may be disabled\n" 150msgid "PCIEX-8000-7H.impact" 151msgstr "Loss of services provided by the device instances associated with this fault\n" 152msgid "PCIEX-8000-7H.action" 153msgstr "Ensure that the latest drivers and patches are installed. Otherwise schedule a repair procedure to replace the affected device(s). Use fmadm faulty to identify the devices or contact Sun for support.\n" 154# 155# code: PCIEX-8000-8R 156# keys: fault.io.pciex.device-invreq 157# 158msgid "PCIEX-8000-8R.type" 159msgstr "Fault" 160msgid "PCIEX-8000-8R.severity" 161msgstr "Major" 162msgid "PCIEX-8000-8R.description" 163msgstr "The transmitting device sent an invalid request.\n Refer to %s for more information." 164msgid "PCIEX-8000-8R.response" 165msgstr "One or more device instances may be disabled\n" 166msgid "PCIEX-8000-8R.impact" 167msgstr "Loss of services provided by the device instances associated with this fault\n" 168msgid "PCIEX-8000-8R.action" 169msgstr "Ensure that the latest drivers and patches are installed. Otherwise schedule a repair procedure to replace the affected device(s). Use fmadm faulty to identify the devices or contact Sun for support.\n" 170# 171# code: PCIEX-8000-94 172# keys: fault.io.pci.device-noresp fault.io.pciex.device-invreq 173# 174msgid "PCIEX-8000-94.type" 175msgstr "Fault" 176msgid "PCIEX-8000-94.severity" 177msgstr "Major" 178msgid "PCIEX-8000-94.description" 179msgstr "Either the transmitting device sent an invalid request or the receiving device failed to respond.\n Refer to %s for more information." 180msgid "PCIEX-8000-94.response" 181msgstr "One or more device instances may be disabled\n" 182msgid "PCIEX-8000-94.impact" 183msgstr "Loss of services provided by the device instances associated with this fault\n" 184msgid "PCIEX-8000-94.action" 185msgstr "Ensure that the latest drivers and patches are installed. If a plug-in card is involved check for badly-seated cards or bent pins. Otherwise schedule a repair procedure to replace the affected device(s). Use fmadm faulty to identify the devices or contact Sun for support.\n" 186# 187# code: PCIEX-8000-AQ 188# keys: fault.io.pci.device-invreq fault.io.pciex.device-noresp 189# 190msgid "PCIEX-8000-AQ.type" 191msgstr "Fault" 192msgid "PCIEX-8000-AQ.severity" 193msgstr "Major" 194msgid "PCIEX-8000-AQ.description" 195msgstr "Either the transmitting device sent an invalid request or the receiving device failed to respond.\n Refer to %s for more information." 196msgid "PCIEX-8000-AQ.response" 197msgstr "One or more device instances may be disabled\n" 198msgid "PCIEX-8000-AQ.impact" 199msgstr "Loss of services provided by the device instances associated with this fault\n" 200msgid "PCIEX-8000-AQ.action" 201msgstr "Ensure that the latest drivers and patches are installed. If a plug-in card is involved check for badly-seated cards or bent pins. Otherwise schedule a repair procedure to replace the affected device(s). Use fmadm faulty to identify the devices or contact Sun for support.\n" 202# 203# code: PCIEX-8000-CC 204# keys: fault.io.pci.bus-linkerr fault.io.pci.device-interr fault.io.pciex.device-interr 205# 206msgid "PCIEX-8000-CC.type" 207msgstr "Fault" 208msgid "PCIEX-8000-CC.severity" 209msgstr "Critical" 210msgid "PCIEX-8000-CC.description" 211msgstr "A problem has been detected on one of the specified devices or on one of the specified connecting buses.\n Refer to %s for more information." 212msgid "PCIEX-8000-CC.response" 213msgstr "One or more device instances may be disabled\n" 214msgid "PCIEX-8000-CC.impact" 215msgstr "Loss of services provided by the device instances associated with this fault\n" 216msgid "PCIEX-8000-CC.action" 217msgstr "If a plug-in card is involved check for badly-seated cards or bent pins. Otherwise schedule a repair procedure to replace the affected device(s). Use fmadm faulty to identify the devices or contact Sun for support.\n" 218# 219# code: PCIEX-8000-DJ 220# keys: fault.io.pciex.bus-noresp fault.io.pciex.device-interr fault.io.pciex.device-noresp 221# 222msgid "PCIEX-8000-DJ.type" 223msgstr "Fault" 224msgid "PCIEX-8000-DJ.severity" 225msgstr "Major" 226msgid "PCIEX-8000-DJ.description" 227msgstr "A problem has been detected on one of the specified devices or on one of the specified connecting buses.\n Refer to %s for more information." 228msgid "PCIEX-8000-DJ.response" 229msgstr "One or more device instances may be disabled\n" 230msgid "PCIEX-8000-DJ.impact" 231msgstr "Loss of services provided by the device instances associated with this fault\n" 232msgid "PCIEX-8000-DJ.action" 233msgstr "If a plug-in card is involved check for badly-seated cards or bent pins. Otherwise schedule a repair procedure to replace the affected device(s). Use fmadm faulty to identify the devices or contact Sun for support.\n" 234# 235# code: PCIEX-8000-EE 236# keys: fault.io.pciex.bus-linkerr fault.io.pciex.bus-noresp fault.io.pciex.device-interr fault.io.pciex.device-noresp 237# 238msgid "PCIEX-8000-EE.type" 239msgstr "Fault" 240msgid "PCIEX-8000-EE.severity" 241msgstr "Critical" 242msgid "PCIEX-8000-EE.description" 243msgstr "A problem has been detected on one of the specified devices or on one of the specified connecting buses.\n Refer to %s for more information." 244msgid "PCIEX-8000-EE.response" 245msgstr "One or more device instances may be disabled\n" 246msgid "PCIEX-8000-EE.impact" 247msgstr "Loss of services provided by the device instances associated with this fault\n" 248msgid "PCIEX-8000-EE.action" 249msgstr "If a plug-in card is involved check for badly-seated cards or bent pins. Otherwise schedule a repair procedure to replace the affected device(s). Use fmadm faulty to identify the devices or contact Sun for support.\n" 250# 251# code: PCIEX-8000-FX 252# keys: fault.io.pciex.bus-linkerr fault.io.pciex.bus-noresp fault.io.pciex.device-interr fault.io.pciex.device-invreq fault.io.pciex.device-noresp 253# 254msgid "PCIEX-8000-FX.type" 255msgstr "Fault" 256msgid "PCIEX-8000-FX.severity" 257msgstr "Critical" 258msgid "PCIEX-8000-FX.description" 259msgstr "A problem has been detected on one of the specified devices or on one of the specified connecting buses.\n Refer to %s for more information." 260msgid "PCIEX-8000-FX.response" 261msgstr "One or more device instances may be disabled\n" 262msgid "PCIEX-8000-FX.impact" 263msgstr "Loss of services provided by the device instances associated with this fault\n" 264msgid "PCIEX-8000-FX.action" 265msgstr "Ensure that the latest drivers and patches are installed. If a plug-in card is involved check for badly-seated cards or bent pins. Otherwise schedule a repair procedure to replace the affected device(s). Use fmadm faulty to identify the devices or contact Sun for support.\n" 266# 267# code: PCIEX-8000-G2 268# keys: fault.io.pciex.bus-noresp fault.io.pciex.device-interr fault.io.pciex.device-invreq fault.io.pciex.device-noresp 269# 270msgid "PCIEX-8000-G2.type" 271msgstr "Fault" 272msgid "PCIEX-8000-G2.severity" 273msgstr "Major" 274msgid "PCIEX-8000-G2.description" 275msgstr "A problem has been detected on one of the specified devices or on one of the specified connecting buses.\n Refer to %s for more information." 276msgid "PCIEX-8000-G2.response" 277msgstr "One or more device instances may be disabled\n" 278msgid "PCIEX-8000-G2.impact" 279msgstr "Loss of services provided by the device instances associated with this fault\n" 280msgid "PCIEX-8000-G2.action" 281msgstr "Ensure that the latest drivers and patches are installed. Otherwise schedule a repair procedure to replace the affected device(s). Use fmadm faulty to identify the devices or contact Sun for support.\n" 282# 283# code: PCIEX-8000-HS 284# keys: fault.io.pciex.bus-noresp fault.io.pciex.device-interr 285# 286msgid "PCIEX-8000-HS.type" 287msgstr "Fault" 288msgid "PCIEX-8000-HS.severity" 289msgstr "Major" 290msgid "PCIEX-8000-HS.description" 291msgstr "A problem has been detected on one of the specified devices or on one of the specified connecting buses.\n Refer to %s for more information." 292msgid "PCIEX-8000-HS.response" 293msgstr "One or more device instances may be disabled\n" 294msgid "PCIEX-8000-HS.impact" 295msgstr "Loss of services provided by the device instances associated with this fault\n" 296msgid "PCIEX-8000-HS.action" 297msgstr "If a plug-in card is involved check for badly-seated cards or bent pins. Otherwise schedule a repair procedure to replace the affected device(s). Use fmadm faulty to identify the devices or contact Sun for support.\n" 298# 299# code: PCIEX-8000-J5 300# keys: fault.io.pciex.device-interr-corr 301# 302msgid "PCIEX-8000-J5.type" 303msgstr "Fault" 304msgid "PCIEX-8000-J5.severity" 305msgstr "Major" 306msgid "PCIEX-8000-J5.description" 307msgstr "Too many recovered internal errors have been detected within the specified PCIEX device. This may degrade into a non-recoverable fault.\n Refer to %s for more information." 308msgid "PCIEX-8000-J5.response" 309msgstr "One or more device instances may be disabled\n" 310msgid "PCIEX-8000-J5.impact" 311msgstr "Loss of services provided by the device instances associated with this fault\n" 312msgid "PCIEX-8000-J5.action" 313msgstr "Schedule a repair procedure to replace the affected device. Use fmadm faulty to identify the device or contact Sun for support.\n" 314# 315# code: PCIEX-8000-KP 316# keys: fault.io.pciex.bus-linkerr-corr fault.io.pciex.device-interr-corr 317# 318msgid "PCIEX-8000-KP.type" 319msgstr "Fault" 320msgid "PCIEX-8000-KP.severity" 321msgstr "Major" 322msgid "PCIEX-8000-KP.description" 323msgstr "Too many recovered bus errors have been detected, which indicates a problem with the specified bus or with the specified transmitting device. This may degrade into an unrecoverable fault.\n Refer to %s for more information." 324msgid "PCIEX-8000-KP.response" 325msgstr "One or more device instances may be disabled\n" 326msgid "PCIEX-8000-KP.impact" 327msgstr "Loss of services provided by the device instances associated with this fault\n" 328msgid "PCIEX-8000-KP.action" 329msgstr "If a plug-in card is involved check for badly-seated cards or bent pins. Otherwise schedule a repair procedure to replace the affected device. Use fmadm faulty to identify the device or contact Sun for support.\n" 330# 331# code: PCIEX-8000-LA 332# keys: fault.io.pci.bus-linkerr-unaf fault.io.pciex.device-interr-unaf 333# 334msgid "PCIEX-8000-LA.type" 335msgstr "Fault" 336msgid "PCIEX-8000-LA.severity" 337msgstr "Major" 338msgid "PCIEX-8000-LA.description" 339msgstr "Too many recovered bus errors have been detected, which indicates a problem with the specified bus or with the specified transmitting device. This may degrade into an unrecoverable fault.\n Refer to %s for more information." 340msgid "PCIEX-8000-LA.response" 341msgstr "One or more device instances may be disabled\n" 342msgid "PCIEX-8000-LA.impact" 343msgstr "Loss of services provided by the device instances associated with this fault\n" 344msgid "PCIEX-8000-LA.action" 345msgstr "If a plug-in card is involved check for badly-seated cards or bent pins. Otherwise schedule a repair procedure to replace the affected device. Use fmadm faulty to identify the device and bus or contact Sun for support.\n" 346# 347# code: PCIEX-8000-MH 348# keys: fault.io.pciex.device-interr-unaf 349# 350msgid "PCIEX-8000-MH.type" 351msgstr "Fault" 352msgid "PCIEX-8000-MH.severity" 353msgstr "Major" 354msgid "PCIEX-8000-MH.description" 355msgstr "Too many recovered errors have been detected, which indicates a problem with the specified PCIEX device. This may degrade into an unrecoverable fault.\n Refer to %s for more information." 356msgid "PCIEX-8000-MH.response" 357msgstr "One or more device instances may be disabled\n" 358msgid "PCIEX-8000-MH.impact" 359msgstr "Loss of services provided by the device instances associated with this fault\n" 360msgid "PCIEX-8000-MH.action" 361msgstr "Schedule a repair procedure to replace the affected device. Use fmadm faulty to identify the device or contact Sun for support.\n" 362# 363# code: PCIEX-8000-ND 364# keys: fault.io.pciex.device-interr-deg 365# 366msgid "PCIEX-8000-ND.type" 367msgstr "Fault" 368msgid "PCIEX-8000-ND.severity" 369msgstr "Major" 370msgid "PCIEX-8000-ND.description" 371msgstr "An unrecoverable problem was detected for a PCIEX device, which has resulted in that device running in a degraded state.\n Refer to %s for more information." 372msgid "PCIEX-8000-ND.response" 373msgstr "None\n" 374msgid "PCIEX-8000-ND.impact" 375msgstr "Degraded services provided by the device instances associated with this fault\n" 376msgid "PCIEX-8000-ND.action" 377msgstr "Schedule a repair procedure to replace the affected device. Use fmadm faulty to identify the device or contact Sun for support.\n" 378# 379# code: PCIEX-8000-PY 380# keys: fault.io.pciex.fw_corrupt 381# 382msgid "PCIEX-8000-PY.type" 383msgstr "Fault" 384msgid "PCIEX-8000-PY.severity" 385msgstr "Major" 386msgid "PCIEX-8000-PY.description" 387msgstr "A firmware corruption was detected for a PCIEX device.\n Refer to %s for more information." 388msgid "PCIEX-8000-PY.response" 389msgstr "One or more device instances may be disabled.\n" 390msgid "PCIEX-8000-PY.impact" 391msgstr "Degraded services provided by the device instances associated with this fault.\n" 392msgid "PCIEX-8000-PY.action" 393msgstr "Use fmadm faulty to identify the device and then update the firmware to the latest version or schedule a repair procedure to replace the affected device. Contact Sun support for further information.\n" 394# 395# code: PCIEX-8000-Q3 396# keys: fault.io.pciex.fw_mismatch 397# 398msgid "PCIEX-8000-Q3.type" 399msgstr "Fault" 400msgid "PCIEX-8000-Q3.severity" 401msgstr "Major" 402msgid "PCIEX-8000-Q3.description" 403msgstr "A firmware version mismatch was detected for a PCIEX device.\n Refer to %s for more information." 404msgid "PCIEX-8000-Q3.response" 405msgstr "One or more device instances may be disabled.\n" 406msgid "PCIEX-8000-Q3.impact" 407msgstr "Degraded services provided by the device instances associated with this fault.\n" 408msgid "PCIEX-8000-Q3.action" 409msgstr "Use fmadm faulty to identify the device and then update the firmware to the latest version. Contact Sun support for further information.\n" 410