xref: /titanic_41/usr/src/cmd/fm/dicts/PCI.po (revision b6917abefc343244b784f0cc34bc65b01469c3bf)
1#
2# Copyright 2008 Sun Microsystems, Inc.  All rights reserved.
3# Use is subject to license terms.
4#
5# CDDL HEADER START
6#
7# The contents of this file are subject to the terms of the
8# Common Development and Distribution License (the "License").
9# You may not use this file except in compliance with the License.
10#
11# You can obtain a copy of the license at usr/src/OPENSOLARIS.LICENSE
12# or http://www.opensolaris.org/os/licensing.
13# See the License for the specific language governing permissions
14# and limitations under the License.
15#
16# When distributing Covered Code, include this CDDL HEADER in each
17# file and include the License file at usr/src/OPENSOLARIS.LICENSE.
18# If applicable, add the following below this CDDL HEADER, with the
19# fields enclosed by brackets "[]" replaced with your own identifying
20# information: Portions Copyright [yyyy] [name of copyright owner]
21#
22# CDDL HEADER END
23#
24#ident	"%Z%%M%	%I%	%E% SMI"
25#
26# DO NOT EDIT -- this file is generated by the Event Registry.
27#
28#
29# code: PCI-8000-0C
30# keys: defect.io.pci.driver
31#
32msgid "PCI-8000-0C.type"
33msgstr "Fault"
34msgid "PCI-8000-0C.severity"
35msgstr "Critical"
36msgid "PCI-8000-0C.description"
37msgstr "A problem was detected in the PCI controller software.  Refer to %s for more information."
38msgid "PCI-8000-0C.response"
39msgstr "One or more of device instances may be disabled."
40msgid "PCI-8000-0C.impact"
41msgstr "Loss of services provided by the device instances associated with this problem."
42msgid "PCI-8000-0C.action"
43msgstr "Ensure latest drivers and patches are installed.  Use fmdump -v -u <EVENT_ID> to identify the module/package, or contact Sun for support."
44#
45# code: PCI-8000-1Q
46# keys: fault.io.pci.bus
47#
48msgid "PCI-8000-1Q.type"
49msgstr "Fault"
50msgid "PCI-8000-1Q.severity"
51msgstr "Critical"
52msgid "PCI-8000-1Q.description"
53msgstr "A problem was detected for a PCI bus.  Refer to %s for more information."
54msgid "PCI-8000-1Q.response"
55msgstr "One or more device instances may be disabled."
56msgid "PCI-8000-1Q.impact"
57msgstr "Loss of services provided by the device instances associated with this fault."
58msgid "PCI-8000-1Q.action"
59msgstr "Schedule a repair procedure to replace the affected device.  Use fmdump -v -u <EVENT_ID> to identify the device or contact Sun for support."
60#
61# code: PCI-8000-24
62# keys: defect.io.pci.driver fault.io.pci.bus
63#
64msgid "PCI-8000-24.type"
65msgstr "Fault"
66msgid "PCI-8000-24.severity"
67msgstr "Critical"
68msgid "PCI-8000-24.description"
69msgstr "The system has diagnosed a problem, the suspects include one or more \nPCI buses and one or more PCI controller drivers.  Refer to %s for more information."
70msgid "PCI-8000-24.response"
71msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
72msgid "PCI-8000-24.impact"
73msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
74msgid "PCI-8000-24.action"
75msgstr "Use fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s)or driver(s).\n\nCheck for patches to identified device drivers, schedule a repair for \nindicated hardware.\n"
76#
77# code: PCI-8000-3R
78# keys: fault.io.pci.device
79#
80msgid "PCI-8000-3R.type"
81msgstr "Fault"
82msgid "PCI-8000-3R.severity"
83msgstr "Critical"
84msgid "PCI-8000-3R.description"
85msgstr "The system has diagnosed a problem in one or more PCI buses or devices, \nbased on the error telemetry detected by the PCI subsystem.  Refer to %s for more information."
86msgid "PCI-8000-3R.response"
87msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
88msgid "PCI-8000-3R.impact"
89msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
90msgid "PCI-8000-3R.action"
91msgstr "Use fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).\n\nSchedule a repair procedure to replace the affected device."
92#
93# code: PCI-8000-42
94# keys: defect.io.pci.driver fault.io.pci.device
95#
96msgid "PCI-8000-42.type"
97msgstr "Fault"
98msgid "PCI-8000-42.severity"
99msgstr "Critical"
100msgid "PCI-8000-42.description"
101msgstr "The system has diagnosed a problem, the suspects include one or more \nPCI buses and one or more PCI controller drivers.  Refer to %s for more information."
102msgid "PCI-8000-42.response"
103msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
104msgid "PCI-8000-42.impact"
105msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
106msgid "PCI-8000-42.action"
107msgstr "Use fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s)or driver(s).\n\nCheck for patches to identified device drivers, schedule a repair for \nindicated hardware.\n"
108#
109# code: PCI-8000-5X
110# keys: fault.io.pci.bus fault.io.pci.device
111#
112msgid "PCI-8000-5X.type"
113msgstr "Fault"
114msgid "PCI-8000-5X.severity"
115msgstr "Critical"
116msgid "PCI-8000-5X.description"
117msgstr "The system has diagnosed a problem in one or more PCI buses or devices, \nbased on the error telemetry detected by the PCI subsystem.  Refer to %s for more information."
118msgid "PCI-8000-5X.response"
119msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
120msgid "PCI-8000-5X.impact"
121msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
122msgid "PCI-8000-5X.action"
123msgstr "Use fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).\n\nSchedule a repair procedure to replace the affected device."
124#
125# code: PCI-8000-6E
126# keys: defect.io.pci.driver fault.io.pci.bus fault.io.pci.device
127#
128msgid "PCI-8000-6E.type"
129msgstr "Fault"
130msgid "PCI-8000-6E.severity"
131msgstr "Critical"
132msgid "PCI-8000-6E.description"
133msgstr "The system has diagnosed a problem, the suspects include one or more \nPCI buses and one or more PCI controller drivers.  Refer to %s for more information."
134msgid "PCI-8000-6E.response"
135msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
136msgid "PCI-8000-6E.impact"
137msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
138msgid "PCI-8000-6E.action"
139msgstr "Use fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s)or driver(s).\n\nCheck for patches to identified device drivers, schedule a repair for \nindicated hardware.\n"
140#
141# code: PCI-8000-7J
142# keys: fault.io.pci.device-interr
143#
144msgid "PCI-8000-7J.type"
145msgstr "Fault"
146msgid "PCI-8000-7J.severity"
147msgstr "Critical"
148msgid "PCI-8000-7J.description"
149msgstr "An unrecoverable problem was detected for a PCI device.\n  Refer to %s for more information."
150msgid "PCI-8000-7J.response"
151msgstr "One or more device instances may be disabled\n"
152msgid "PCI-8000-7J.impact"
153msgstr "Possible loss of services provided by the device instances associated with this fault\n"
154msgid "PCI-8000-7J.action"
155msgstr "Schedule a repair procedure to replace the affected device.  Use fmadm faulty to identify the device or contact Sun for support.\n"
156#
157# code: PCI-8000-8S
158# keys: fault.io.pci.bus-linkerr fault.io.pci.device-interr
159#
160msgid "PCI-8000-8S.type"
161msgstr "Fault"
162msgid "PCI-8000-8S.severity"
163msgstr "Critical"
164msgid "PCI-8000-8S.description"
165msgstr "An unrecoverable problem has been detected on the specified bus or on the specified transmitting device.\n  Refer to %s for more information."
166msgid "PCI-8000-8S.response"
167msgstr "One or more device instances may be disabled\n"
168msgid "PCI-8000-8S.impact"
169msgstr "Possible loss of services provided by the device instances associated with this fault\n"
170msgid "PCI-8000-8S.action"
171msgstr "If a plug-in card is involved check for badly-seated cards or bent pins. Otherwise schedule a repair procedure to replace the affected device.  Use fmadm faulty to identify the device and bus or contact Sun for support.\n"
172#
173# code: PCI-8000-95
174# keys: fault.io.pci.device-invreq fault.io.pci.device-noresp
175#
176msgid "PCI-8000-95.type"
177msgstr "Fault"
178msgid "PCI-8000-95.severity"
179msgstr "Major"
180msgid "PCI-8000-95.description"
181msgstr "Either the transmitting device sent an invalid request or the receiving device failed to respond.\n  Refer to %s for more information."
182msgid "PCI-8000-95.response"
183msgstr "One or more device instances may be disabled\n"
184msgid "PCI-8000-95.impact"
185msgstr "Possible loss of services provided by the device instances associated with this fault\n"
186msgid "PCI-8000-95.action"
187msgstr "Ensure that the latest drivers and patches are installed. If a plug-in card is involved check for badly-seated cards or bent pins.  Otherwise schedule a repair procedure to replace the affected device(s).  Use fmadm faulty to identify the devices or contact Sun for support.\n"
188#
189# code: PCI-8000-AP
190# keys: fault.io.pci.device-interr fault.io.pci.device-invreq
191#
192msgid "PCI-8000-AP.type"
193msgstr "Fault"
194msgid "PCI-8000-AP.severity"
195msgstr "Major"
196msgid "PCI-8000-AP.description"
197msgstr "Either the transmitting device sent an invalid request or the receiving device is reporting an internal fault.\n  Refer to %s for more information."
198msgid "PCI-8000-AP.response"
199msgstr "One or more device instances may be disabled\n"
200msgid "PCI-8000-AP.impact"
201msgstr "Possible loss of services provided by the device instances associated with this fault\n"
202msgid "PCI-8000-AP.action"
203msgstr "Ensure that the latest drivers and patches are installed.  Otherwise schedule a repair procedure to replace the affected device(s).  Use fmadm faulty to identify the devices or contact Sun for support.\n"
204#
205# code: PCI-8000-CA
206# keys: fault.io.pci.device-noresp
207#
208msgid "PCI-8000-CA.type"
209msgstr "Fault"
210msgid "PCI-8000-CA.severity"
211msgstr "Major"
212msgid "PCI-8000-CA.description"
213msgstr "A device is failing to respond\n  Refer to %s for more information."
214msgid "PCI-8000-CA.response"
215msgstr "One or more device instances may be disabled\n"
216msgid "PCI-8000-CA.impact"
217msgstr "Possible loss of services provided by the device instances associated with this fault\n"
218msgid "PCI-8000-CA.action"
219msgstr "Schedule a repair procedure to replace the affected device.  Use fmadm faulty to identify the device or contact Sun for support.\n"
220#
221# code: PCI-8000-DH
222# keys: fault.io.pci.bus-linkerr-unaf fault.io.pci.device-interr-unaf
223#
224msgid "PCI-8000-DH.type"
225msgstr "Fault"
226msgid "PCI-8000-DH.severity"
227msgstr "Major"
228msgid "PCI-8000-DH.description"
229msgstr "Too many recovered bus faults have been detected, which indicates a problem with the specified bus or with the specified transmitting device. This may degrade into an unrecoverable fault.\n  Refer to %s for more information."
230msgid "PCI-8000-DH.response"
231msgstr "One or more device instances may be disabled\n"
232msgid "PCI-8000-DH.impact"
233msgstr "Possible loss of services provided by the device instances associated with this fault\n"
234msgid "PCI-8000-DH.action"
235msgstr "If a plug-in card is involved check for badly-seated cards or bent pins. Otherwise schedule a repair procedure to replace the affected device.  Use fmadm faulty to identify the device and bus or contact Sun for support.\n"
236#
237# code: PCI-8000-ED
238# keys: fault.io.pci.device-interr-corr
239#
240msgid "PCI-8000-ED.type"
241msgstr "Fault"
242msgid "PCI-8000-ED.severity"
243msgstr "Major"
244msgid "PCI-8000-ED.description"
245msgstr "Too many recovered internal faults have been detected within the specified PCI device. This may degrade into a non-recoverable fault.\n  Refer to %s for more information."
246msgid "PCI-8000-ED.response"
247msgstr "One or more device instances may be disabled\n"
248msgid "PCI-8000-ED.impact"
249msgstr "Possible loss of services provided by the device instances associated with this fault\n"
250msgid "PCI-8000-ED.action"
251msgstr "Schedule a repair procedure to replace the affected device.  Use fmadm faulty to identify the device or contact Sun for support.\n"
252#
253# code: PCI-8000-FY
254# keys: fault.io.pci.bus-linkerr-deg fault.io.pci.device-interr-deg
255#
256msgid "PCI-8000-FY.type"
257msgstr "Fault"
258msgid "PCI-8000-FY.severity"
259msgstr "Major"
260msgid "PCI-8000-FY.description"
261msgstr "An unrecoverable problem has been detected on the specified bus or on the specified transmitting device, which has resulted in that device running in a degraded state.\n  Refer to %s for more information."
262msgid "PCI-8000-FY.response"
263msgstr "None\n"
264msgid "PCI-8000-FY.impact"
265msgstr "Degraded services provided by the device instances associated with this fault\n"
266msgid "PCI-8000-FY.action"
267msgstr "If a plug-in card is involved check for badly-seated cards or bent pins. Otherwise schedule a repair procedure to replace the affected device.  Use fmadm faulty to identify the device and bus or contact Sun for support.\n"
268#
269# code: PCI-8000-G3
270# keys: fault.io.pci.device-interr-deg
271#
272msgid "PCI-8000-G3.type"
273msgstr "Fault"
274msgid "PCI-8000-G3.severity"
275msgstr "Major"
276msgid "PCI-8000-G3.description"
277msgstr "An unrecoverable problem was detected for a PCI device, which has resulted in that device running in a degraded state.\n  Refer to %s for more information."
278msgid "PCI-8000-G3.response"
279msgstr "None\n"
280msgid "PCI-8000-G3.impact"
281msgstr "Degraded services provided by the device instances associated with this fault\n"
282msgid "PCI-8000-G3.action"
283msgstr "Schedule a repair procedure to replace the affected device.  Use fmadm faulty to identify the device or contact Sun for support.\n"
284