1# 2# Copyright 2006 Sun Microsystems, Inc. All rights reserved. 3# Use is subject to license terms. 4# 5# CDDL HEADER START 6# 7# The contents of this file are subject to the terms of the 8# Common Development and Distribution License (the "License"). 9# You may not use this file except in compliance with the License. 10# 11# You can obtain a copy of the license at usr/src/OPENSOLARIS.LICENSE 12# or http://www.opensolaris.org/os/licensing. 13# See the License for the specific language governing permissions 14# and limitations under the License. 15# 16# When distributing Covered Code, include this CDDL HEADER in each 17# file and include the License file at usr/src/OPENSOLARIS.LICENSE. 18# If applicable, add the following below this CDDL HEADER, with the 19# fields enclosed by brackets "[]" replaced with your own identifying 20# information: Portions Copyright [yyyy] [name of copyright owner] 21# 22# CDDL HEADER END 23# 24#ident "%Z%%M% %I% %E% SMI" 25# 26# DO NOT EDIT -- this file is generated by the Event Registry. 27# 28# 29# code: PCI-8000-0C 30# keys: defect.io.pci.driver 31# 32msgid "PCI-8000-0C.type" 33msgstr "Fault" 34msgid "PCI-8000-0C.severity" 35msgstr "Critical" 36msgid "PCI-8000-0C.description" 37msgstr "A problem was detected in the PCI controller software. Refer to %s for more information." 38msgid "PCI-8000-0C.response" 39msgstr "One or more of device instances may be disabled." 40msgid "PCI-8000-0C.impact" 41msgstr "Loss of services provided by the device instances associated with this problem." 42msgid "PCI-8000-0C.action" 43msgstr "Ensure latest drivers and patches are installed. Use fmdump -v -u <EVENT_ID> to identify the module/package, or contact Sun for support." 44# 45# code: PCI-8000-1Q 46# keys: fault.io.pci.bus 47# 48msgid "PCI-8000-1Q.type" 49msgstr "Fault" 50msgid "PCI-8000-1Q.severity" 51msgstr "Critical" 52msgid "PCI-8000-1Q.description" 53msgstr "A problem was detected for a PCI bus. Refer to %s for more information." 54msgid "PCI-8000-1Q.response" 55msgstr "One or more device instances may be disabled." 56msgid "PCI-8000-1Q.impact" 57msgstr "Loss of services provided by the device instances associated with this fault." 58msgid "PCI-8000-1Q.action" 59msgstr "Schedule a repair procedure to replace the affected device. Use fmdump -v -u <EVENT_ID> to identify the device or contact Sun for support." 60# 61# code: PCI-8000-24 62# keys: defect.io.pci.driver fault.io.pci.bus 63# 64msgid "PCI-8000-24.type" 65msgstr "Fault" 66msgid "PCI-8000-24.severity" 67msgstr "Critical" 68msgid "PCI-8000-24.description" 69msgstr "The system has diagnosed a problem, the suspects include one or more \nPCI buses and one or more PCI controller drivers. Refer to %s for more information." 70msgid "PCI-8000-24.response" 71msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 72msgid "PCI-8000-24.impact" 73msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 74msgid "PCI-8000-24.action" 75msgstr "Use fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s)or driver(s).\n\nCheck for patches to identified device drivers, schedule a repair for \nindicated hardware.\n" 76# 77# code: PCI-8000-3R 78# keys: fault.io.pci.device 79# 80msgid "PCI-8000-3R.type" 81msgstr "Fault" 82msgid "PCI-8000-3R.severity" 83msgstr "Critical" 84msgid "PCI-8000-3R.description" 85msgstr "The system has diagnosed a problem in one or more PCI buses or devices, \nbased on the error telemetry detected by the PCI subsystem. Refer to %s for more information." 86msgid "PCI-8000-3R.response" 87msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 88msgid "PCI-8000-3R.impact" 89msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 90msgid "PCI-8000-3R.action" 91msgstr "Use fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).\n\nSchedule a repair procedure to replace the affected device." 92# 93# code: PCI-8000-42 94# keys: defect.io.pci.driver fault.io.pci.device 95# 96msgid "PCI-8000-42.type" 97msgstr "Fault" 98msgid "PCI-8000-42.severity" 99msgstr "Critical" 100msgid "PCI-8000-42.description" 101msgstr "The system has diagnosed a problem, the suspects include one or more \nPCI buses and one or more PCI controller drivers. Refer to %s for more information." 102msgid "PCI-8000-42.response" 103msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 104msgid "PCI-8000-42.impact" 105msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 106msgid "PCI-8000-42.action" 107msgstr "Use fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s)or driver(s).\n\nCheck for patches to identified device drivers, schedule a repair for \nindicated hardware.\n" 108# 109# code: PCI-8000-5X 110# keys: fault.io.pci.bus fault.io.pci.device 111# 112msgid "PCI-8000-5X.type" 113msgstr "Fault" 114msgid "PCI-8000-5X.severity" 115msgstr "Critical" 116msgid "PCI-8000-5X.description" 117msgstr "The system has diagnosed a problem in one or more PCI buses or devices, \nbased on the error telemetry detected by the PCI subsystem. Refer to %s for more information." 118msgid "PCI-8000-5X.response" 119msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 120msgid "PCI-8000-5X.impact" 121msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 122msgid "PCI-8000-5X.action" 123msgstr "Use fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).\n\nSchedule a repair procedure to replace the affected device." 124# 125# code: PCI-8000-6E 126# keys: defect.io.pci.driver fault.io.pci.bus fault.io.pci.device 127# 128msgid "PCI-8000-6E.type" 129msgstr "Fault" 130msgid "PCI-8000-6E.severity" 131msgstr "Critical" 132msgid "PCI-8000-6E.description" 133msgstr "The system has diagnosed a problem, the suspects include one or more \nPCI buses and one or more PCI controller drivers. Refer to %s for more information." 134msgid "PCI-8000-6E.response" 135msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 136msgid "PCI-8000-6E.impact" 137msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 138msgid "PCI-8000-6E.action" 139msgstr "Use fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s)or driver(s).\n\nCheck for patches to identified device drivers, schedule a repair for \nindicated hardware.\n" 140# 141# code: PCI-8000-7J 142# keys: fault.io.pci.device-interr 143# 144msgid "PCI-8000-7J.type" 145msgstr "Fault" 146msgid "PCI-8000-7J.severity" 147msgstr "Critical" 148msgid "PCI-8000-7J.description" 149msgstr "A problem was detected for a PCI device.\n Refer to %s for more information." 150msgid "PCI-8000-7J.response" 151msgstr "One or more device instances may be disabled\n" 152msgid "PCI-8000-7J.impact" 153msgstr "Possible loss of services provided by the device instances associated with this fault\n" 154msgid "PCI-8000-7J.action" 155msgstr "Schedule a repair procedure to replace the affected device. Use fmdump -v -u to identify the device or contact Sun for support.\n" 156# 157# code: PCI-8000-8S 158# keys: fault.io.pci.bus-linkerr fault.io.pci.device-interr 159# 160msgid "PCI-8000-8S.type" 161msgstr "Fault" 162msgid "PCI-8000-8S.severity" 163msgstr "Critical" 164msgid "PCI-8000-8S.description" 165msgstr "A problem has been detected on the specified bus or on the specified transmitting device.\n Refer to %s for more information." 166msgid "PCI-8000-8S.response" 167msgstr "One or more device instances may be disabled\n" 168msgid "PCI-8000-8S.impact" 169msgstr "Possible loss of services provided by the device instances associated with this fault\n" 170msgid "PCI-8000-8S.action" 171msgstr "If a plug-in card is involved check for badly-seated cards or bent pins. Otherwise schedule a repair procedure to replace the affected device. Use fmdump -v -u to identify the device and bus or contact Sun for support.\n" 172# 173# code: PCI-8000-95 174# keys: fault.io.pci.device-invreq fault.io.pci.device-noresp 175# 176msgid "PCI-8000-95.type" 177msgstr "Fault" 178msgid "PCI-8000-95.severity" 179msgstr "Critical" 180msgid "PCI-8000-95.description" 181msgstr "Either the transmitting device sent an invalid request or the receiving device failed to respond.\n Refer to %s for more information." 182msgid "PCI-8000-95.response" 183msgstr "One or more device instances may be disabled\n" 184msgid "PCI-8000-95.impact" 185msgstr "Possible loss of services provided by the device instances associated with this fault\n" 186msgid "PCI-8000-95.action" 187msgstr "Ensure that the latest drivers and patches are installed. If a plug-in card is involved check for badly-seated cards or bent pins. Otherwise schedule a repair procedure to replace the affected device(s). Use fmdump -v -u to identify the devices or contact Sun for support.\n" 188# 189# code: PCI-8000-AP 190# keys: fault.io.pci.device-interr fault.io.pci.device-invreq 191# 192msgid "PCI-8000-AP.type" 193msgstr "Fault" 194msgid "PCI-8000-AP.severity" 195msgstr "Critical" 196msgid "PCI-8000-AP.description" 197msgstr "Either the transmitting device sent an invalid request or the receiving device is reporting an internal fault.\n Refer to %s for more information." 198msgid "PCI-8000-AP.response" 199msgstr "One or more device instances may be disabled\n" 200msgid "PCI-8000-AP.impact" 201msgstr "Possible loss of services provided by the device instances associated with this fault\n" 202msgid "PCI-8000-AP.action" 203msgstr "Ensure that the latest drivers and patches are installed. Otherwise schedule a repair procedure to replace the affected device(s). Use fmdump -v -u to identify the devices or contact Sun for support.\n" 204# 205# code: PCI-8000-CA 206# keys: fault.io.pci.device-noresp 207# 208msgid "PCI-8000-CA.type" 209msgstr "Fault" 210msgid "PCI-8000-CA.severity" 211msgstr "Critical" 212msgid "PCI-8000-CA.description" 213msgstr "Device is failing to respond\n Refer to %s for more information." 214msgid "PCI-8000-CA.response" 215msgstr "One or more device instances may be disabled\n" 216msgid "PCI-8000-CA.impact" 217msgstr "Possible loss of services provided by the device instances associated with this fault\n" 218msgid "PCI-8000-CA.action" 219msgstr "Schedule a repair procedure to replace the affected device. Use fmdump -v -u to identify the device or contact Sun for support.\n" 220