xref: /titanic_41/usr/src/cmd/fm/dicts/PCI.po (revision 29949e866e40b95795203f3ee46f44a197c946e4)
1#
2# Copyright 2005 Sun Microsystems, Inc.  All rights reserved.
3# Use is subject to license terms.
4#
5# CDDL HEADER START
6#
7# The contents of this file are subject to the terms of the
8# Common Development and Distribution License, Version 1.0 only
9# (the "License").  You may not use this file except in compliance
10# with the License.
11#
12# You can obtain a copy of the license at usr/src/OPENSOLARIS.LICENSE
13# or http://www.opensolaris.org/os/licensing.
14# See the License for the specific language governing permissions
15# and limitations under the License.
16#
17# When distributing Covered Code, include this CDDL HEADER in each
18# file and include the License file at usr/src/OPENSOLARIS.LICENSE.
19# If applicable, add the following below this CDDL HEADER, with the
20# fields enclosed by brackets "[]" replaced with your own identifying
21# information: Portions Copyright [yyyy] [name of copyright owner]
22#
23# CDDL HEADER END
24#
25#ident	"%Z%%M%	%I%	%E% SMI"
26
27#
28# code: PCI-8000-0C
29# keys: defect.io.pci.driver
30#
31msgid "PCI-8000-0C.type"
32msgstr "Fault"
33msgid "PCI-8000-0C.severity"
34msgstr "Critical"
35msgid "PCI-8000-0C.description"
36msgstr "A problem was detected in the PCI controller software"
37msgid "PCI-8000-0C.response"
38msgstr "One or more of device instances may be disabled"
39msgid "PCI-8000-0C.impact"
40msgstr "Loss of services provided by the device instances associated with this fault"
41msgid "PCI-8000-0C.action"
42msgstr "Ensure latest drivers and patches are installed. Use fmdump -v -u <EVENT_ID> to identify the module/package, or contact Sun for support."
43#
44# code: PCI-8000-1Q
45# keys: fault.io.pci.bus
46#
47msgid "PCI-8000-1Q.type"
48msgstr "Fault"
49msgid "PCI-8000-1Q.severity"
50msgstr "Critical"
51msgid "PCI-8000-1Q.description"
52msgstr "A problem was detected for a PCI bus.  Refer to %s for more information."
53msgid "PCI-8000-1Q.response"
54msgstr "One or more device instances may be disabled"
55msgid "PCI-8000-1Q.impact"
56msgstr "Loss of services provided by the device instances associated with this fault"
57msgid "PCI-8000-1Q.action"
58msgstr "Schedule a repair procedure to replace the affected device.  Use fmdump -v -u <EVENT_ID> to identify the device or contact Sun for support."
59#
60# code: PCI-8000-24
61# keys: defect.io.pci.driver fault.io.pci.bus
62#
63msgid "PCI-8000-24.type"
64msgstr "Fault"
65msgid "PCI-8000-24.severity"
66msgstr "Critical"
67msgid "PCI-8000-24.description"
68msgstr "A problem was detected in the PCI subsystem or controlling software.  Refer to %s for more information."
69msgid "PCI-8000-24.response"
70msgstr "One or more device instances may be disabled"
71msgid "PCI-8000-24.impact"
72msgstr "Loss of services provided by the device instances associated with this fault"
73msgid "PCI-8000-24.action"
74msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
75#
76# code: PCI-8000-3R
77# keys: fault.io.pci.device
78#
79msgid "PCI-8000-3R.type"
80msgstr "Fault"
81msgid "PCI-8000-3R.severity"
82msgstr "Critical"
83msgid "PCI-8000-3R.description"
84msgstr "A problem was detected for a PCI controller.  Refer to %s for more information."
85msgid "PCI-8000-3R.response"
86msgstr "One or more device instances may be disabled"
87msgid "PCI-8000-3R.impact"
88msgstr "Loss of services provided by the device instances associated with this fault"
89msgid "PCI-8000-3R.action"
90msgstr "Schedule a repair procedure to replace the affected device.  Use fmdump -v -u <EVENT_ID> to identify the device or contact Sun for support."
91#
92# code: PCI-8000-42
93# keys: defect.io.pci.driver fault.io.pci.device
94#
95msgid "PCI-8000-42.type"
96msgstr "Fault"
97msgid "PCI-8000-42.severity"
98msgstr "Critical"
99msgid "PCI-8000-42.description"
100msgstr "A problem was detected in the SUNOS subsystem or controlling software.  Refer to %s for more information."
101msgid "PCI-8000-42.response"
102msgstr "One or more device instances may be disabled"
103msgid "PCI-8000-42.impact"
104msgstr "Loss of services provided by the device instances associated with this fault"
105msgid "PCI-8000-42.action"
106msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
107#
108# code: PCI-8000-5X
109# keys: fault.io.pci.bus fault.io.pci.device
110#
111msgid "PCI-8000-5X.type"
112msgstr "Fault"
113msgid "PCI-8000-5X.severity"
114msgstr "Critical"
115msgid "PCI-8000-5X.description"
116msgstr "A problem was detected in the PCI subsystem.  Refer to %s for more information."
117msgid "PCI-8000-5X.response"
118msgstr "One or more device instances may be disabled"
119msgid "PCI-8000-5X.impact"
120msgstr "Loss of services provided by the device instances associated with this fault"
121msgid "PCI-8000-5X.action"
122msgstr "Schedule a repair procedure to replace the affected device.  Use fmdump -v -u <EVENT_ID> to identify the device or contact Sun for support."
123#
124# code: PCI-8000-6E
125# keys: defect.io.pci.driver fault.io.pci.bus fault.io.pci.device
126#
127msgid "PCI-8000-6E.type"
128msgstr "Fault"
129msgid "PCI-8000-6E.severity"
130msgstr "Critical"
131msgid "PCI-8000-6E.description"
132msgstr "A problem was detected in the SUNOS subsystem or controlling software. Refer to %s for more information."
133msgid "PCI-8000-6E.response"
134msgstr "One or more device instances may be disabled"
135msgid "PCI-8000-6E.impact"
136msgstr "Loss of services provided by the device instances associated with this fault"
137msgid "PCI-8000-6E.action"
138msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
139