1# 2# Copyright 2006 Sun Microsystems, Inc. All rights reserved. 3# Use is subject to license terms. 4# 5# CDDL HEADER START 6# 7# The contents of this file are subject to the terms of the 8# Common Development and Distribution License (the "License"). 9# You may not use this file except in compliance with the License. 10# 11# You can obtain a copy of the license at usr/src/OPENSOLARIS.LICENSE 12# or http://www.opensolaris.org/os/licensing. 13# See the License for the specific language governing permissions 14# and limitations under the License. 15# 16# When distributing Covered Code, include this CDDL HEADER in each 17# file and include the License file at usr/src/OPENSOLARIS.LICENSE. 18# If applicable, add the following below this CDDL HEADER, with the 19# fields enclosed by brackets "[]" replaced with your own identifying 20# information: Portions Copyright [yyyy] [name of copyright owner] 21# 22# CDDL HEADER END 23# 24#ident "%Z%%M% %I% %E% SMI" 25# 26# DO NOT EDIT -- this file is generated by the Event Registry. 27# 28# 29# General-purpose messages 30# 31msgid "syslog-msgs-message-template" 32msgstr "SUNW-MSG-ID: %s, TYPE: %s, VER: 1, SEVERITY: %s\nEVENT-TIME: %s\nPLATFORM: %s, CSN: %s, HOSTNAME: %s\nSOURCE: %s, REV: %s\nEVENT-ID: %s\nDESC: %s\nAUTO-RESPONSE: %s\nIMPACT: %s\nREC-ACTION: %s\n" 33# 34# Fault-related messages 35# 36# 37# 38# code: FMD-8000-0W 39# keys: defect.sunos.fmd.nosub 40# 41msgid "FMD-8000-0W.type" 42msgstr "Defect" 43msgid "FMD-8000-0W.severity" 44msgstr "Minor" 45msgid "FMD-8000-0W.description" 46msgstr "The Solaris Fault Manager received an event from a component to which no automated diagnosis software is currently subscribed. Refer to %s for more information." 47msgid "FMD-8000-0W.response" 48msgstr "Error reports from the component will be logged for examination by Sun." 49msgid "FMD-8000-0W.impact" 50msgstr "Automated diagnosis and response for these events will not occur." 51msgid "FMD-8000-0W.action" 52msgstr "Run pkgchk -n SUNWfmd to ensure that fault management software is installed properly. Contact Sun for support." 53# 54# code: FMD-8000-11 55# keys: defect.sunos.fmd.nodiagcode 56# 57msgid "FMD-8000-11.type" 58msgstr "Defect" 59msgid "FMD-8000-11.severity" 60msgstr "Minor" 61msgid "FMD-8000-11.description" 62msgstr "A Solaris Fault Manager component generated a diagnosis for which no message summary exists. Refer to %s for more information." 63msgid "FMD-8000-11.response" 64msgstr "The diagnosis has been saved in the fault log for examination by Sun." 65msgid "FMD-8000-11.impact" 66msgstr "The fault log will need to be manually examined using fmdump(1M) in order to determine if any human response is required." 67msgid "FMD-8000-11.action" 68msgstr "Use fmdump -v -u <EVENT-ID> to view the diagnosis result. Run pkgchk -n SUNWfmd to ensure that fault management software is installed properly." 69# 70# code: FMD-8000-2K 71# keys: defect.sunos.fmd.module 72# 73msgid "FMD-8000-2K.type" 74msgstr "Defect" 75msgid "FMD-8000-2K.severity" 76msgstr "Minor" 77msgid "FMD-8000-2K.description" 78msgstr "A Solaris Fault Manager component has experienced an error that required the module to be disabled. Refer to %s for more information." 79msgid "FMD-8000-2K.response" 80msgstr "The module has been disabled. Events destined for the module will be saved for manual diagnosis." 81msgid "FMD-8000-2K.impact" 82msgstr "Automated diagnosis and response for subsequent events associated with this module will not occur." 83msgid "FMD-8000-2K.action" 84msgstr "Use fmdump -v -u <EVENT-ID> to locate the module. Use fmadm reset <module> to reset the module." 85# 86# code: FMD-8000-3F 87# keys: defect.sunos.fmd.config 88# 89msgid "FMD-8000-3F.type" 90msgstr "Defect" 91msgid "FMD-8000-3F.severity" 92msgstr "Minor" 93msgid "FMD-8000-3F.description" 94msgstr "A Solaris Fault Manager component could not load due to an erroroneous configuration file. Refer to %s for more information." 95msgid "FMD-8000-3F.response" 96msgstr "The module has been disabled. Events destined for the module will be saved for manual diagnosis." 97msgid "FMD-8000-3F.impact" 98msgstr "Automated diagnosis and response for subsequent events associated with this module will not occur." 99msgid "FMD-8000-3F.action" 100msgstr "Use fmdump -v -u <EVENT-ID> to locate the module. Use fmadm load <module> to load the module after repairing its configuration." 101