1# 2# Copyright 2010 Sun Microsystems, Inc. All rights reserved. 3# Use is subject to license terms. 4# 5# CDDL HEADER START 6# 7# The contents of this file are subject to the terms of the 8# Common Development and Distribution License (the "License"). 9# You may not use this file except in compliance with the License. 10# 11# You can obtain a copy of the license at usr/src/OPENSOLARIS.LICENSE 12# or http://www.opensolaris.org/os/licensing. 13# See the License for the specific language governing permissions 14# and limitations under the License. 15# 16# When distributing Covered Code, include this CDDL HEADER in each 17# file and include the License file at usr/src/OPENSOLARIS.LICENSE. 18# If applicable, add the following below this CDDL HEADER, with the 19# fields enclosed by brackets "[]" replaced with your own identifying 20# information: Portions Copyright [yyyy] [name of copyright owner] 21# 22# CDDL HEADER END 23# 24# DO NOT EDIT -- this file is generated by the Event Registry. 25# 26# 27# General-purpose messages 28# 29msgid "syslog-msgs-message-template" 30msgstr "SUNW-MSG-ID: %s, TYPE: %s, VER: 1, SEVERITY: %s\nEVENT-TIME: %s\nPLATFORM: %s, CSN: %s, HOSTNAME: %s\nSOURCE: %s, REV: %s\nEVENT-ID: %s\nDESC: %s\nAUTO-RESPONSE: %s\nIMPACT: %s\nREC-ACTION: %s\n" 31msgid "syslog-msgs-pointer" 32msgstr "\n...\nSee fmadm faulty -u <EVENT-ID> for full information.\n" 33 34# 35# Fault-related messages 36# 37# 38# 39# code: FMD-8000-0W 40# keys: defect.sunos.fmd.nosub 41# 42msgid "FMD-8000-0W.type" 43msgstr "Defect" 44msgid "FMD-8000-0W.severity" 45msgstr "Minor" 46msgid "FMD-8000-0W.description" 47msgstr "The Solaris Fault Manager received an event %<fault-list[0].nosub_class> to which no automated diagnosis software is currently subscribed. Refer to %s for more information." 48msgid "FMD-8000-0W.response" 49msgstr "Error reports from the component will be logged for examination by Sun." 50msgid "FMD-8000-0W.impact" 51msgstr "Automated diagnosis and response for these events will not occur." 52msgid "FMD-8000-0W.action" 53msgstr "Run pkgchk -n SUNWfmd to ensure that fault management software is installed properly. Contact Sun for support." 54# 55# code: FMD-8000-11 56# keys: defect.sunos.fmd.nodiagcode 57# 58msgid "FMD-8000-11.type" 59msgstr "Defect" 60msgid "FMD-8000-11.severity" 61msgstr "Minor" 62msgid "FMD-8000-11.description" 63msgstr "A Solaris Fault Manager component generated a diagnosis for which no message summary exists. Refer to %s for more information." 64msgid "FMD-8000-11.response" 65msgstr "The diagnosis has been saved in the fault log for examination by Sun." 66msgid "FMD-8000-11.impact" 67msgstr "The fault log will need to be manually examined using fmdump(1M) in order to determine if any human response is required." 68msgid "FMD-8000-11.action" 69msgstr "Use fmdump -v -u <EVENT-ID> to view the diagnosis result. Run pkgchk -n SUNWfmd to ensure that fault management software is installed properly." 70# 71# code: FMD-8000-2K 72# keys: defect.sunos.fmd.module 73# 74msgid "FMD-8000-2K.type" 75msgstr "Defect" 76msgid "FMD-8000-2K.severity" 77msgstr "Minor" 78msgid "FMD-8000-2K.description" 79msgstr "A Solaris Fault Manager component has experienced an error that required the module to be disabled. Refer to %s for more information." 80msgid "FMD-8000-2K.response" 81msgstr "The module has been disabled. Events destined for the module will be saved for manual diagnosis." 82msgid "FMD-8000-2K.impact" 83msgstr "Automated diagnosis and response for subsequent events associated with this module will not occur." 84msgid "FMD-8000-2K.action" 85msgstr "Use fmdump -v -u <EVENT-ID> to locate the module. Use fmadm reset <module> to reset the module." 86# 87# code: FMD-8000-3F 88# keys: defect.sunos.fmd.config 89# 90msgid "FMD-8000-3F.type" 91msgstr "Defect" 92msgid "FMD-8000-3F.severity" 93msgstr "Minor" 94msgid "FMD-8000-3F.description" 95msgstr "A Solaris Fault Manager component could not load due to an erroroneous configuration file. Refer to %s for more information." 96msgid "FMD-8000-3F.response" 97msgstr "The module has been disabled. Events destined for the module will be saved for manual diagnosis." 98msgid "FMD-8000-3F.impact" 99msgstr "Automated diagnosis and response for subsequent events associated with this module will not occur." 100msgid "FMD-8000-3F.action" 101msgstr "Use fmdump -v -u <EVENT-ID> to locate the module. Use fmadm load <module> to load the module after repairing its configuration." 102# 103# code: FMD-8000-4M 104# keys: list.repaired 105# 106msgid "FMD-8000-4M.type" 107msgstr "Repair" 108msgid "FMD-8000-4M.severity" 109msgstr "Minor" 110msgid "FMD-8000-4M.description" 111msgstr "All faults associated with an event id have been addressed.\n Refer to %s for more information." 112msgid "FMD-8000-4M.response" 113msgstr "Some system components offlined because of the original fault may have been brought back online.\n" 114msgid "FMD-8000-4M.impact" 115msgstr "Performance degradation of the system due to the original fault may have been recovered.\n" 116msgid "FMD-8000-4M.action" 117msgstr "Use fmdump -v -u <EVENT-ID> to identify the repaired components." 118# 119# code: FMD-8000-58 120# keys: list.updated 121# 122msgid "FMD-8000-58.type" 123msgstr "Update" 124msgid "FMD-8000-58.severity" 125msgstr "Minor" 126msgid "FMD-8000-58.description" 127msgstr "Some faults associated with an event id have been addressed.\n Refer to %s for more information." 128msgid "FMD-8000-58.response" 129msgstr "Some system components offlined because of the original fault may have been brought back online.\n" 130msgid "FMD-8000-58.impact" 131msgstr "Performance degradation of the system due to the original fault may have been recovered.\n" 132msgid "FMD-8000-58.action" 133msgstr "Use fmadm faulty to identify the repaired components, and any suspects that still need to be repaired.\n" 134# 135# code: FMD-8000-6U 136# keys: list.resolved 137# 138msgid "FMD-8000-6U.type" 139msgstr "Resolved" 140msgid "FMD-8000-6U.severity" 141msgstr "Minor" 142msgid "FMD-8000-6U.description" 143msgstr "All faults associated with an event id have been addressed.\n Refer to %s for more information." 144msgid "FMD-8000-6U.response" 145msgstr "All system components offlined because of the original fault have been brought back online.\n" 146msgid "FMD-8000-6U.impact" 147msgstr "Performance degradation of the system due to the original fault has been recovered.\n" 148msgid "FMD-8000-6U.action" 149msgstr "Use fmdump -v -u <EVENT-ID> to identify the repaired components.\n" 150