1# 2# Copyright 2008 Sun Microsystems, Inc. All rights reserved. 3# Use is subject to license terms. 4# 5# CDDL HEADER START 6# 7# The contents of this file are subject to the terms of the 8# Common Development and Distribution License (the "License"). 9# You may not use this file except in compliance with the License. 10# 11# You can obtain a copy of the license at usr/src/OPENSOLARIS.LICENSE 12# or http://www.opensolaris.org/os/licensing. 13# See the License for the specific language governing permissions 14# and limitations under the License. 15# 16# When distributing Covered Code, include this CDDL HEADER in each 17# file and include the License file at usr/src/OPENSOLARIS.LICENSE. 18# If applicable, add the following below this CDDL HEADER, with the 19# fields enclosed by brackets "[]" replaced with your own identifying 20# information: Portions Copyright [yyyy] [name of copyright owner] 21# 22# CDDL HEADER END 23# 24#ident "%Z%%M% %I% %E% SMI" 25# 26# DO NOT EDIT -- this file is generated by the Event Registry. 27# 28# 29# General-purpose messages 30# 31msgid "syslog-msgs-message-template" 32msgstr "SUNW-MSG-ID: %s, TYPE: %s, VER: 1, SEVERITY: %s\nEVENT-TIME: %s\nPLATFORM: %s, CSN: %s, HOSTNAME: %s\nSOURCE: %s, REV: %s\nEVENT-ID: %s\nDESC: %s\nAUTO-RESPONSE: %s\nIMPACT: %s\nREC-ACTION: %s\n" 33msgid "syslog-msgs-pointer" 34msgstr "\n...\nSee fmadm faulty -u <EVENT-ID> for full information.\n" 35 36# 37# Fault-related messages 38# 39# 40# 41# code: FMD-8000-0W 42# keys: defect.sunos.fmd.nosub 43# 44msgid "FMD-8000-0W.type" 45msgstr "Defect" 46msgid "FMD-8000-0W.severity" 47msgstr "Minor" 48msgid "FMD-8000-0W.description" 49msgstr "The Solaris Fault Manager received an event from a component to which no automated diagnosis software is currently subscribed. Refer to %s for more information." 50msgid "FMD-8000-0W.response" 51msgstr "Error reports from the component will be logged for examination by Sun." 52msgid "FMD-8000-0W.impact" 53msgstr "Automated diagnosis and response for these events will not occur." 54msgid "FMD-8000-0W.action" 55msgstr "Run pkgchk -n SUNWfmd to ensure that fault management software is installed properly. Contact Sun for support." 56# 57# code: FMD-8000-11 58# keys: defect.sunos.fmd.nodiagcode 59# 60msgid "FMD-8000-11.type" 61msgstr "Defect" 62msgid "FMD-8000-11.severity" 63msgstr "Minor" 64msgid "FMD-8000-11.description" 65msgstr "A Solaris Fault Manager component generated a diagnosis for which no message summary exists. Refer to %s for more information." 66msgid "FMD-8000-11.response" 67msgstr "The diagnosis has been saved in the fault log for examination by Sun." 68msgid "FMD-8000-11.impact" 69msgstr "The fault log will need to be manually examined using fmdump(1M) in order to determine if any human response is required." 70msgid "FMD-8000-11.action" 71msgstr "Use fmdump -v -u <EVENT-ID> to view the diagnosis result. Run pkgchk -n SUNWfmd to ensure that fault management software is installed properly." 72# 73# code: FMD-8000-2K 74# keys: defect.sunos.fmd.module 75# 76msgid "FMD-8000-2K.type" 77msgstr "Defect" 78msgid "FMD-8000-2K.severity" 79msgstr "Minor" 80msgid "FMD-8000-2K.description" 81msgstr "A Solaris Fault Manager component has experienced an error that required the module to be disabled. Refer to %s for more information." 82msgid "FMD-8000-2K.response" 83msgstr "The module has been disabled. Events destined for the module will be saved for manual diagnosis." 84msgid "FMD-8000-2K.impact" 85msgstr "Automated diagnosis and response for subsequent events associated with this module will not occur." 86msgid "FMD-8000-2K.action" 87msgstr "Use fmdump -v -u <EVENT-ID> to locate the module. Use fmadm reset <module> to reset the module." 88# 89# code: FMD-8000-3F 90# keys: defect.sunos.fmd.config 91# 92msgid "FMD-8000-3F.type" 93msgstr "Defect" 94msgid "FMD-8000-3F.severity" 95msgstr "Minor" 96msgid "FMD-8000-3F.description" 97msgstr "A Solaris Fault Manager component could not load due to an erroroneous configuration file. Refer to %s for more information." 98msgid "FMD-8000-3F.response" 99msgstr "The module has been disabled. Events destined for the module will be saved for manual diagnosis." 100msgid "FMD-8000-3F.impact" 101msgstr "Automated diagnosis and response for subsequent events associated with this module will not occur." 102msgid "FMD-8000-3F.action" 103msgstr "Use fmdump -v -u <EVENT-ID> to locate the module. Use fmadm load <module> to load the module after repairing its configuration." 104# 105# code: FMD-8000-4M 106# keys: list.repaired 107# 108msgid "FMD-8000-4M.type" 109msgstr "Repair" 110msgid "FMD-8000-4M.severity" 111msgstr "Minor" 112msgid "FMD-8000-4M.description" 113msgstr "All faults associated with an event id have been addressed.\n Refer to %s for more information." 114msgid "FMD-8000-4M.response" 115msgstr "Some system components offlined because of the original fault may have been brought back online.\n" 116msgid "FMD-8000-4M.impact" 117msgstr "Performance degradation of the system due to the original fault may have been recovered.\n" 118msgid "FMD-8000-4M.action" 119msgstr "Use fmdump -v -u <EVENT-ID> to identify the repaired components." 120# 121# code: FMD-8000-58 122# keys: list.updated 123# 124msgid "FMD-8000-58.type" 125msgstr "Update" 126msgid "FMD-8000-58.severity" 127msgstr "Minor" 128msgid "FMD-8000-58.description" 129msgstr "Some faults associated with an event id have been addressed.\n Refer to %s for more information." 130msgid "FMD-8000-58.response" 131msgstr "Some system components offlined because of the original fault may have been brought back online.\n" 132msgid "FMD-8000-58.impact" 133msgstr "Performance degradation of the system due to the original fault may have been recovered.\n" 134msgid "FMD-8000-58.action" 135msgstr "Use fmadm faulty to identify the repaired components, and any suspects that still need to be repaired.\n" 136# 137# code: FMD-8000-6U 138# keys: list.resolved 139# 140msgid "FMD-8000-6U.type" 141msgstr "Resolved" 142msgid "FMD-8000-6U.severity" 143msgstr "Minor" 144msgid "FMD-8000-6U.description" 145msgstr "All faults associated with an event id have been addressed.\n Refer to %s for more information." 146msgid "FMD-8000-6U.response" 147msgstr "All system components offlined because of the original fault have been brought back online.\n" 148msgid "FMD-8000-6U.impact" 149msgstr "Performance degradation of the system due to the original fault has been recovered.\n" 150msgid "FMD-8000-6U.action" 151msgstr "Use fmdump -v -u <EVENT-ID> to identify the repaired components.\n" 152