1# 2# Copyright (c) 2010, Oracle and/or its affiliates. All rights reserved. 3# 4# CDDL HEADER START 5# 6# The contents of this file are subject to the terms of the 7# Common Development and Distribution License (the "License"). 8# You may not use this file except in compliance with the License. 9# 10# You can obtain a copy of the license at usr/src/OPENSOLARIS.LICENSE 11# or http://www.opensolaris.org/os/licensing. 12# See the License for the specific language governing permissions 13# and limitations under the License. 14# 15# When distributing Covered Code, include this CDDL HEADER in each 16# file and include the License file at usr/src/OPENSOLARIS.LICENSE. 17# If applicable, add the following below this CDDL HEADER, with the 18# fields enclosed by brackets "[]" replaced with your own identifying 19# information: Portions Copyright [yyyy] [name of copyright owner] 20# 21# CDDL HEADER END 22# 23 24# DO NOT EDIT -- this file is generated by the Event Registry. 25# 26# 27# General-purpose messages 28# 29msgid "syslog-msgs-message-template" 30msgstr "SUNW-MSG-ID: %s, TYPE: %s, VER: 1, SEVERITY: %s\nEVENT-TIME: %s\nPLATFORM: %s, CSN: %s, HOSTNAME: %s\nSOURCE: %s, REV: %s\nEVENT-ID: %s\nDESC: %s\nAUTO-RESPONSE: %s\nIMPACT: %s\nREC-ACTION: %s\n" 31# 32# Fault-related messages 33# 34# 35# 36# code: FMD-8000-0W 37# keys: defect.sunos.fmd.nosub 38# 39msgid "FMD-8000-0W.type" 40msgstr "Defect" 41msgid "FMD-8000-0W.severity" 42msgstr "Minor" 43msgid "FMD-8000-0W.description" 44msgstr "The Solaris Fault Manager received an event from a component to which no automated diagnosis software is currently subscribed. Refer to %s for more information." 45msgid "FMD-8000-0W.response" 46msgstr "Error reports from the component will be logged for examination by Sun." 47msgid "FMD-8000-0W.impact" 48msgstr "Automated diagnosis and response for these events will not occur." 49msgid "FMD-8000-0W.action" 50msgstr "Run pkgchk -n SUNWfmd to ensure that fault management software is installed properly. Contact Sun for support." 51# 52# code: FMD-8000-11 53# keys: defect.sunos.fmd.nodiagcode 54# 55msgid "FMD-8000-11.type" 56msgstr "Defect" 57msgid "FMD-8000-11.severity" 58msgstr "Minor" 59msgid "FMD-8000-11.description" 60msgstr "A Solaris Fault Manager component generated a diagnosis for which no message summary exists. Refer to %s for more information." 61msgid "FMD-8000-11.response" 62msgstr "The diagnosis has been saved in the fault log for examination by Sun." 63msgid "FMD-8000-11.impact" 64msgstr "The fault log will need to be manually examined using fmdump(1M) in order to determine if any human response is required." 65msgid "FMD-8000-11.action" 66msgstr "Use fmdump -v -u <EVENT-ID> to view the diagnosis result. Run pkgchk -n SUNWfmd to ensure that fault management software is installed properly." 67# 68# code: FMD-8000-2K 69# keys: defect.sunos.fmd.module 70# 71msgid "FMD-8000-2K.type" 72msgstr "Defect" 73msgid "FMD-8000-2K.severity" 74msgstr "Minor" 75msgid "FMD-8000-2K.description" 76msgstr "A Solaris Fault Manager component has experienced an error that required the module to be disabled. Refer to %s for more information." 77msgid "FMD-8000-2K.response" 78msgstr "The module has been disabled. Events destined for the module will be saved for manual diagnosis." 79msgid "FMD-8000-2K.impact" 80msgstr "Automated diagnosis and response for subsequent events associated with this module will not occur." 81msgid "FMD-8000-2K.action" 82msgstr "Use fmdump -v -u <EVENT-ID> to locate the module. Use fmadm reset <module> to reset the module." 83# 84# code: FMD-8000-3F 85# keys: defect.sunos.fmd.config 86# 87msgid "FMD-8000-3F.type" 88msgstr "Defect" 89msgid "FMD-8000-3F.severity" 90msgstr "Minor" 91msgid "FMD-8000-3F.description" 92msgstr "A Solaris Fault Manager component could not load due to an erroroneous configuration file. Refer to %s for more information." 93msgid "FMD-8000-3F.response" 94msgstr "The module has been disabled. Events destined for the module will be saved for manual diagnosis." 95msgid "FMD-8000-3F.impact" 96msgstr "Automated diagnosis and response for subsequent events associated with this module will not occur." 97msgid "FMD-8000-3F.action" 98msgstr "Use fmdump -v -u <EVENT-ID> to locate the module. Use fmadm load <module> to load the module after repairing its configuration." 99# 100# code: FMD-8000-4M 101# keys: list.repaired 102# 103msgid "FMD-8000-4M.type" 104msgstr "Repair" 105msgid "FMD-8000-4M.severity" 106msgstr "Minor" 107msgid "FMD-8000-4M.description" 108msgstr "All faults associated with an event id have been addressed.\n Refer to %s for more information." 109msgid "FMD-8000-4M.response" 110msgstr "Some system components offlined because of the original fault may have been brought back online." 111msgid "FMD-8000-4M.impact" 112msgstr "Performance degradation of the system due to the original fault may have been recovered." 113msgid "FMD-8000-4M.action" 114msgstr "Use fmdump -v -u <EVENT-ID> to identify the repaired components." 115# 116# code: FMD-8000-58 117# keys: list.updated 118# 119msgid "FMD-8000-58.type" 120msgstr "Update" 121msgid "FMD-8000-58.severity" 122msgstr "Minor" 123msgid "FMD-8000-58.description" 124msgstr "Some faults associated with an event id have been addressed.\n Refer to %s for more information." 125msgid "FMD-8000-58.response" 126msgstr "Some system components offlined because of the original fault may have been brought back online." 127msgid "FMD-8000-58.impact" 128msgstr "Performance degradation of the system due to the original fault may have been recovered." 129msgid "FMD-8000-58.action" 130msgstr "Use fmadm faulty to identify the repaired components, and any suspects that still need to be repaired." 131# 132# code: FMD-8000-6U 133# keys: list.resolved 134# 135msgid "FMD-8000-6U.type" 136msgstr "Resolved" 137msgid "FMD-8000-6U.severity" 138msgstr "Minor" 139msgid "FMD-8000-6U.description" 140msgstr "All faults associated with an event id have been addressed.\n Refer to %s for more information." 141msgid "FMD-8000-6U.response" 142msgstr "All system components offlined because of the original fault have been brought back online." 143msgid "FMD-8000-6U.impact" 144msgstr "Performance degradation of the system due to the original fault has been recovered." 145msgid "FMD-8000-6U.action" 146msgstr "Use fmdump -v -u <EVENT-ID> to identify the repaired components." 147