1# 2# Copyright 2006 Sun Microsystems, Inc. All rights reserved. 3# Use is subject to license terms. 4# 5# CDDL HEADER START 6# 7# The contents of this file are subject to the terms of the 8# Common Development and Distribution License (the "License"). 9# You may not use this file except in compliance with the License. 10# 11# You can obtain a copy of the license at usr/src/OPENSOLARIS.LICENSE 12# or http://www.opensolaris.org/os/licensing. 13# See the License for the specific language governing permissions 14# and limitations under the License. 15# 16# When distributing Covered Code, include this CDDL HEADER in each 17# file and include the License file at usr/src/OPENSOLARIS.LICENSE. 18# If applicable, add the following below this CDDL HEADER, with the 19# fields enclosed by brackets "[]" replaced with your own identifying 20# information: Portions Copyright [yyyy] [name of copyright owner] 21# 22# CDDL HEADER END 23# 24#ident "%Z%%M% %I% %E% SMI" 25# 26# DO NOT EDIT -- this file is generated by the Event Registry. 27# 28# 29# code: DISK-8000-0X 30# keys: fault.io.disk.predictive-failure 31# 32msgid "DISK-8000-0X.type" 33msgstr "Fault" 34msgid "DISK-8000-0X.severity" 35msgstr "Major" 36msgid "DISK-8000-0X.description" 37msgstr "SMART health-monitoring firmware reported that a disk\nfailure is imminent.\n Refer to %s for more information." 38msgid "DISK-8000-0X.response" 39msgstr "None.\n" 40msgid "DISK-8000-0X.impact" 41msgstr "It is likely that the continued operation of\nthis disk will result in data loss.\n" 42msgid "DISK-8000-0X.action" 43msgstr "Schedule a repair procedure to replace the affected disk.\nUse fmdump -v -u <EVENT_ID> to identify the disk.\n" 44# 45# code: DISK-8000-12 46# keys: fault.io.disk.over-temperature 47# 48msgid "DISK-8000-12.type" 49msgstr "Fault" 50msgid "DISK-8000-12.severity" 51msgstr "Major" 52msgid "DISK-8000-12.description" 53msgstr "A disk's temperature exceeded the limits established by\nits manufacturer.\n Refer to %s for more information." 54msgid "DISK-8000-12.response" 55msgstr "None.\n" 56msgid "DISK-8000-12.impact" 57msgstr "Performance degradation is likely and continued disk operation\nbeyond the temperature threshold can result in disk\ndamage and potential data loss.\n" 58msgid "DISK-8000-12.action" 59msgstr "Ensure that the system is properly cooled, that all fans are\nfunctional, and that there are no obstructions of airflow to the affected\ndisk.\n" 60# 61# code: DISK-8000-2J 62# keys: fault.io.disk.self-test-failure 63# 64msgid "DISK-8000-2J.type" 65msgstr "Fault" 66msgid "DISK-8000-2J.severity" 67msgstr "Critical" 68msgid "DISK-8000-2J.description" 69msgstr "One or more disk self tests failed.\n Refer to %s for more information." 70msgid "DISK-8000-2J.response" 71msgstr "None.\n" 72msgid "DISK-8000-2J.impact" 73msgstr "The disk has failed.\n" 74msgid "DISK-8000-2J.action" 75msgstr "Schedule a repair procedure to replace the affected disk.\nUse fmdump -v -u <EVENT_ID> to identify the disk.\n" 76