1# 2# Copyright 2008 Sun Microsystems, Inc. All rights reserved. 3# Use is subject to license terms. 4# 5# CDDL HEADER START 6# 7# The contents of this file are subject to the terms of the 8# Common Development and Distribution License (the "License"). 9# You may not use this file except in compliance with the License. 10# 11# You can obtain a copy of the license at usr/src/OPENSOLARIS.LICENSE 12# or http://www.opensolaris.org/os/licensing. 13# See the License for the specific language governing permissions 14# and limitations under the License. 15# 16# When distributing Covered Code, include this CDDL HEADER in each 17# file and include the License file at usr/src/OPENSOLARIS.LICENSE. 18# If applicable, add the following below this CDDL HEADER, with the 19# fields enclosed by brackets "[]" replaced with your own identifying 20# information: Portions Copyright [yyyy] [name of copyright owner] 21# 22# CDDL HEADER END 23# 24# 25# DO NOT EDIT -- this file is generated by the Event Registry. 26# 27# 28# code: DISK-8000-0X 29# keys: fault.io.disk.predictive-failure 30# 31msgid "DISK-8000-0X.type" 32msgstr "Fault" 33msgid "DISK-8000-0X.severity" 34msgstr "Major" 35msgid "DISK-8000-0X.description" 36msgstr "SMART health-monitoring firmware reported that a disk\nfailure is imminent.\n Refer to %s for more information." 37msgid "DISK-8000-0X.response" 38msgstr "None.\n" 39msgid "DISK-8000-0X.impact" 40msgstr "It is likely that the continued operation of\nthis disk will result in data loss.\n" 41msgid "DISK-8000-0X.action" 42msgstr "Schedule a repair procedure to replace the affected disk.\nUse fmdump -v -u <EVENT_ID> to identify the disk.\n" 43# 44# code: DISK-8000-12 45# keys: fault.io.disk.over-temperature 46# 47msgid "DISK-8000-12.type" 48msgstr "Fault" 49msgid "DISK-8000-12.severity" 50msgstr "Major" 51msgid "DISK-8000-12.description" 52msgstr "A disk's temperature exceeded the limits established by\nits manufacturer.\n Refer to %s for more information." 53msgid "DISK-8000-12.response" 54msgstr "None.\n" 55msgid "DISK-8000-12.impact" 56msgstr "Performance degradation is likely and continued disk operation\nbeyond the temperature threshold can result in disk\ndamage and potential data loss.\n" 57msgid "DISK-8000-12.action" 58msgstr "Ensure that the system is properly cooled, that all fans are\nfunctional, and that there are no obstructions of airflow to the affected\ndisk.\n" 59# 60# code: DISK-8000-2J 61# keys: fault.io.disk.self-test-failure 62# 63msgid "DISK-8000-2J.type" 64msgstr "Fault" 65msgid "DISK-8000-2J.severity" 66msgstr "Critical" 67msgid "DISK-8000-2J.description" 68msgstr "One or more disk self tests failed.\n Refer to %s for more information." 69msgid "DISK-8000-2J.response" 70msgstr "None.\n" 71msgid "DISK-8000-2J.impact" 72msgstr "The disk has failed.\n" 73msgid "DISK-8000-2J.action" 74msgstr "Schedule a repair procedure to replace the affected disk.\nUse fmdump -v -u <EVENT_ID> to identify the disk.\n" 75# 76# code: DISK-8000-3E 77# keys: fault.io.scsi.cmd.disk.dev.rqs.derr 78# 79msgid "DISK-8000-3E.type" 80msgstr "Fault" 81msgid "DISK-8000-3E.severity" 82msgstr "Critical" 83msgid "DISK-8000-3E.description" 84msgstr "A non-recoverable hardware failure was detected by the device while performing a command.\n Refer to %s for more information." 85msgid "DISK-8000-3E.response" 86msgstr "The device may be offlined or degraded.\n" 87msgid "DISK-8000-3E.impact" 88msgstr "The device has failed. The service may have been lost or degraded.\n" 89msgid "DISK-8000-3E.action" 90msgstr "Ensure that the latest drivers and patches are installed. Schedule a repair procedure to replace the affected\ndevice. Use 'fmadm faulty' to find the affected disk.\n" 91# 92# code: DISK-8000-4Q 93# keys: fault.io.scsi.cmd.disk.dev.rqs.merr 94# 95msgid "DISK-8000-4Q.type" 96msgstr "Fault" 97msgid "DISK-8000-4Q.severity" 98msgstr "Critical" 99msgid "DISK-8000-4Q.description" 100msgstr "The command was terminated with a non-recovered error condition that may have been caused by a flaw in the media or an error in the recorded data. \n Refer to %s for more information." 101msgid "DISK-8000-4Q.response" 102msgstr "The device may be offlined or degraded.\n" 103msgid "DISK-8000-4Q.impact" 104msgstr "It is likely that continued operation will result in data corruption, which may eventually cause the loss of service or the service degradation.\n" 105msgid "DISK-8000-4Q.action" 106msgstr "Schedule a repair procedure to replace the affected device. Use 'fmadm faulty' to find the affected disk.\n" 107