sasinfo hba [-v] [HBA_Name]...
sasinfo hba-port [-lvy] [-a HBA_Name] [HBA_port_nam]...
sasinfo expander [-vt] [-p HBA_port_Name] [Expander_SAS_Addr]...
sasinfo target-port [-s | -v] [Target_port_SAS_Addr]...
sasinfo logical-unit | lu [-v] [device_path]...
sasinfo [-V]
sasinfo [-?]
The sasinfo utility is a command line interface that collects administrative information on Serial Attached SCSI-2 (SAS-2) host bus adapter (HBA) that supports the Storage Management HBA API (SM-HBA). The utility reports attributes of HBA ports and of expander devices and SCSI target devices that might be connected to those HBA ports.
sasinfo is implemented as a set of subcommands, described below.
The following subcommands are supported by sasinfo. hba
Lists information for the HBA referenced by the specified HBA_name. If HBA_name is not specified, all HBAs on the host will be listed.
Lists information for the HBA port referenced by the specified HBA_port_Name. If HBA_port_Name is not specified, all HBA ports on the host will be listed. Note that HBA ports can be dynamically configured/unconfigured so that the number of HBA ports on an HBA can change as connections to target devices are established. With no connections to a storage device, no HBA port is configured.
Lists hierarchical view of the expander referenced by the specified Expander_SAS_Addr. If no argument is specified, all expanders that are visible across all HBA ports on the host will be listed.
Lists information for those target ports referenced by Target_port_SAS_Addr address. If no argument is specified, all target ports that are visible on the host will be listed.
Lists the logical unit referenced by the specified device_path. If device_path is not specified, all SAS logical units will be listed, including the SAS Management Protocol (SMP) target port.
The following options are supported. -?, --help
Displays usage information
Retrieve HBA port information from the HBA_Name of an HBA on the host. The -a option can only be used with the hba-port subcommand.
Lists the link error statistics information for the phys on the HBA port referenced by the specified HBA_port_Name or all HBA ports if no HBA port is specified. This option is used only with the hba-port subcommand.
Retrieve remote port information from the HBA_port_SAS_Addr of the local HBA port on the host. The -p option can be used only with the expander subcommand.
Lists SCSI attributes for target ports that are requested for display. This option is only used for the target-port subcommand.
Display details on hardware information, such as SAS address, topology device, and so forth, based on which subcommand is invoked.
Displays the version information.
Lists the phy information on the HBA port specified by HBA_port_Name or all HBA ports if no HBA port is specified. This option is used only with the hba-port subcommand.
Example 1 Listing All HBAs
The following command lists all HBAs on the host.
# sasinfo hba
HBA Name: SUNW-pmcs-0
HBA Name: SUNW-pmcs-1
Example 2 Listing All HBAs with Details
The following command lists all HBAs on the host, along with related details. Note that each HBA has two HBA ports configured, with each HBA port connected to a storage device.
# sasinfo hba -v HBA Name: SUNW-pmcs-0 Manufacturer: sun Model: SAS Gen-2 Firmware Version: 1.1 FCode/BIOS Version: 1.1 Serial Number: 111-11111 Driver Name: smvsl Driver Version: 1.1 Number of HBA Ports: 2 HBA Name: SUNW-pmcs-1 Manufacturer: sun Model: SAS Gen-2 Firmware Version: 1.1 FCode/BIOS Version: 1.1 Serial Number: 111-11111 Driver Name: smvsl Driver Version: 1.1 Number of HBA Ports: 2
Example 3 Listing All HBA Ports
The following command lists all HBA ports on the host.
# sasinfo hba-port HBA Name: SUNW-pmcs-0 HBA Port Name: /dev/cfg/c1 HBA Port Name: /dev/cfg/c2 HBA Name: SUNW-pmcs-1 HBA Port Name: /dev/cfg/c3 HBA Port Name: /dev/cfg/c4
Example 4 Listing all HBA Ports with Details
The following command lists all HBA ports, with accompanying details.
# sasinfo hba-port -v HBA Name: SUNW-pmcs-0 HBA Port Name: /dev/cfg/c1 Type: sas-device State: online Local SAS Address: 5000c50000d756aa Attached Port SAS Address: 50800201a5a502bf Number of Phys: 4 HBA Port Name: /dev/cfg/c25000c50000d756cc Type: sas-device State: online Local SAS Address: 5000c50000d756aa Attached Port SAS Address: 50800201a5a503bf Number of Phys: 4 HBA Name: SUNW-pmcs-1 HBA Port Name: /dev/cfg/c3 Type: sas-device State: online Local SAS Address: 5000c50000d756cc Attached Port SAS Address: 50800201a5a504bf Number of Phys: 4 HBA Port Name: /dev/cfg/c4 Type: sas-device State: online Local SAS Address: 5000c50000d756cc Attached Port SAS Address: 50800201a5a505bf Number of Phys: 4
Example 5 Listing phy Information for All HBA Ports
The following command lists phy information for all HBA ports.
# sasinfo hba-port -y HBA Name: SUNW-pmcs-0 HBA Port Name: /dev/cfg/c1 Phy Information: Identifier: 0 State: enabled HardwareLinkRate(Min/Max): 1.5Gbit/3Gbit ProgrammedLinkRate(Min/Max): 1.5Gbit/3Gbit NegotiatedLinkRate: 3Gbit Identifier: 1 State: enabled HardwareLinkRate(Min/Max): 1.5Gbit/3Gbit ProgrammedLinkRate(Min/Max): 1.5Gbit/3Gbit NegotiatedLinkRate: 3Gbit Identifier: 2 State: enabled HardwareLinkRate(Min/Max): 1.5Gbit/3Gbit ProgrammedLinkRate(Min/Max): 1.5Gbit/3Gbit NegotiatedLinkRate: 3Gbit Identifier: 3 State: enabled HardwareLinkRate(Min/Max): 1.5Gbit/3Gbit ProgrammedLinkRate(Min/Max): 1.5Gbit/3Gbit NegotiatedLinkRate: 3Gbit HBA Port Name: /dev/cfg/c2 Phy Information: Identifier: 4 State: enabled HardwareLinkRate(Min/Max): 1.5Gbit/3Gbit ProgrammedLinkRate(Min/Max): 1.5Gbit/3Gbit NegotiatedLinkRate: 3Gbit Identifier: 5 State: enabled HardwareLinkRate(Min/Max): 1.5Gbit/3Gbit ProgrammedLinkRate(Min/Max): 1.5Gbit/3Gbit NegotiatedLinkRate: 3Gbit Identifier: 6 State: enabled HardwareLinkRate(Min/Max): 1.5Gbit/3Gbit ProgrammedLinkRate(Min/Max): 1.5Gbit/3Gbit NegotiatedLinkRate: 3Gbit Identifier: 7 State: enabled HardwareLinkRate(Min/Max): 1.5Gbit/3Gbit ProgrammedLinkRate(Min/Max): 1.5Gbit/3Gbit NegotiatedLinkRate: 3Gbit HBA Name: SUNW-pmcs-1 HBA Port Name: /dev/cfg/c3 Phy Information: Identifier: 0 State: enabled HardwareLinkRate(Min/Max): 1.5Gbit/3Gbit ProgrammedLinkRate(Min/Max): 1.5Gbit/3Gbit NegotiatedLinkRate: 3Gbit Identifier: 1 State: enabled HardwareLinkRate(Min/Max): 1.5Gbit/3Gbit ProgrammedLinkRate(Min/Max): 1.5Gbit/3Gbit NegotiatedLinkRate: 3Gbit Identifier: 2 State: enabled HardwareLinkRate(Min/Max): 1.5Gbit/3Gbit ProgrammedLinkRate(Min/Max): 1.5Gbit/3Gbit NegotiatedLinkRate: 3Gbit Identifier: 3 State: enabled HardwareLinkRate(Min/Max): 1.5Gbit/3Gbit ProgrammedLinkRate(Min/Max): 1.5Gbit/3Gbit NegotiatedLinkRate: 3Gbit HBA Port Name: /dev/cfg/c4 Phy Information: Identifier: 4 State: enabled HardwareLinkRate(Min/Max): 1.5Gbit/3Gbit ProgrammedLinkRate(Min/Max): 1.5Gbit/3Gbit NegotiatedLinkRate: 3Gbit Identifier: 5 State: enabled HardwareLinkRate(Min/Max): 1.5Gbit/3Gbit ProgrammedLinkRate(Min/Max): 1.5Gbit/3Gbit NegotiatedLinkRate: 3Gbit Identifier: 6 State: enabled HardwareLinkRate(Min/Max): 1.5Gbit/3Gbit ProgrammedLinkRate(Min/Max): 1.5Gbit/3Gbit NegotiatedLinkRate: 3Gbit Identifier: 7 State: enabled HardwareLinkRate(Min/Max): 1.5Gbit/3Gbit ProgrammedLinkRate(Min/Max): 1.5Gbit/3Gbit NegotiatedLinkRate: 3Gbit
Example 6 Listing phy Link Error Statistics for a Specific HBA Port
The following command lists phy link error statistics for a particular port.
# sasinfo hba-port -ly /dev/cfg/c1 HBA Name: SUNW-pmcs-0 HBA Port Name: /dev/cfg/c1 Phy Information: Identifier: 0 State: enabled HardwareLinkRate(Min/Max): 1.5Gbit/3Gbit ProgrammedLinkRate(Min/Max): 1.5Gbit/3Gbit NegotiatedLinkRate: 3Gbit Link Error Statistics: Invalid Dword: 0 Running Disparity Error: 0 Loss of Dword Sync: 0 Reset Problem: 0 Identifier: 1 State: enabled HardwareLinkRate(Min/Max): 1.5Gbit/3Gbit ProgrammedLinkRate(Min/Max): 1.5Gbit/3Gbit NegotiatedLinkRate: 3Gbit Link Error Statistics: Invalid Dword: 0 Running Disparity Error: 0 Loss of Dword Sync: 0 Reset Problem: 0 Identifier: 2 State: enabled HardwareLinkRate(Min/Max): 1.5Gbit/3Gbit ProgrammedLinkRate(Min/Max): 1.5Gbit/3Gbit NegotiatedLinkRate: 3Gbit Link Error Statistics: Invalid Dword: 0 Running Disparity Error: 0 Loss of Dword Sync: 0 Reset Problem: 0 Identifier: 3 State: enabled HardwareLinkRate(Min/Max): 1.5Gbit/3Gbit ProgrammedLinkRate(Min/Max): 1.5Gbit/3Gbit NegotiatedLinkRate: 3Gbit Link Error Statistics: Invalid Dword: 0 Running Disparity Error: 0 Loss of Dword Sync: 0 Reset Problem: 0
Example 7 Listing Expanders Connected to an HBA Port
The following command lists all expanders that are visible through the specified HBA port.
# sasinfo expander -p /dev/cfg/c1 HBA Name: SUNW-pmcs-0 HBA Port Name: /dev/cfg/c1 Expander SAS Address(Tier 1): 50800201a5a502bf Expander SAS Address(Tier 2): 50800201a5a50233 Expander SAS Address(Tier 2); 5000c5000d2da812 Expander SAS Address(Tier 1): 50800201a5a503bf Expander SAS Address(Tier 2): 50800201a5a502d2 Expander SAS Address(Tier 2); 5000c5000d2da823
Example 8 Listing Detailed Information on Expanders
The following command lists detailed information on all expanders that are visible through the specified HBA port.
# sasinfo expander -v -p /dev/cfg/c1 HBA Name: SUNW-pmcs-0 HBA Port Name: /dev/cfg/c1 Expander SAS Address(Tier 1): 50800201a5a502bf OS Device Name: /dev/smp/expd0 State: online Expander SAS Address(Tier 2): 50800201a5a50233 OS Device Name: /dev/smp/expd2 State: online Expander SAS Address(Tier 2); 5000c5000d2da812 OS Device Name: /dev/smp/expd3 State: online Expander SAS Address(Tier 1): 50800201a5a503bf OS Device Name: /dev/smp/expd1 State: online Expander SAS Address(Tier 2): 50800201a5a502d2 OS Device Name: /dev/smp/expd3 State: online Expander SAS Address(Tier 2); 5000c5000d2da823 OS Device Name: /dev/smp/expd4 State: online
Example 9 Listing Target Ports Attached to Expanders
The following command lists all target ports that are attached to expanders connected to a specified HBA port.
# sasinfo expander -t -p /dev/cfg/c1 HBA Name: SUNW-pmcs-0 HBA Port Name: /dev/cfg/c1 Expander SAS Address(Tier 1): 50800201a5a502bf Target Port SAS Address: 50800201a5a504f1 Expander SAS Address(Tier 2): 50800201a5a50233 Target Port SAS Address: 50800201a5a502be Target Port SAS Address: 5000c5000d2da8b2 Expander SAS Address(Tier 2); 5000c5000d2da812 Target Port SAS Address: 50800201a5a502be Target Port SAS Address: 50800201a5a508b2 Expander SAS Address(Tier 1): 50800201a5a503bf Target Port SAS Address: 50800201a5a50421 Expander SAS Address(Tier 2): 50800201a5a502d2 Target Port SAS Address: 50800201a5a503be Target Port SAS Address: 5000c5000d2da7be Expander SAS Address(Tier 2); 5000c5000d2da823 Target Port SAS Address: 50800201a5a503be Target Port SAS Address: 5000c5000d2da7be
Example 10 Listing Target Port Information
The following command lists all target ports discovered on the host.
# sasinfo target-port
Target Port SAS Address: 5000c5000bae4009
Target Port SAS Address: 5000c5000baef4b1
Target Port SAS Address: 5000c5000bae3fe1
Target Port SAS Address: 5000c5000bae49d9
Target Port SAS Address: 5000c5000bae36c5
Example 11 Listing Target Port Information with Topology Details
The following command lists all target ports with the HBA port and expander that they are connected to.
# sasinfo target-port -v Target Port SAS Address: 5000c5000bae4009 Type: SAS Device HBA Port Name: /dev/cfg/c7 Expander Device SAS Address: 500e004aaaaaaa3f HBA Port Name: /dev/cfg/c5 Expander Device SAS Address: 500e004aaaaaaa3f Target Port SAS Address: 5000c5000baef4b1 Type: SAS Device HBA Port Name: /dev/cfg/c7 Expander Device SAS Address: 500e004aaaaaaa3f HBA Port Name: /dev/cfg/c5 Expander Device SAS Address: 500e004aaaaaaa3f Target Port SAS Address: 5000c5000bae3fe1 Type: SAS Device HBA Port Name: /dev/cfg/c7 Expander Device SAS Address: 500e004aaaaaaa3f HBA Port Name: /dev/cfg/c5 Expander Device SAS Address: 500e004aaaaaaa3f Target Port SAS Address: 5000c5000bae49d9 Type: SAS Device HBA Port Name: /dev/cfg/c7 Expander Device SAS Address: 500e004aaaaaaa3f HBA Port Name: /dev/cfg/c5 Expander Device SAS Address: 500e004aaaaaaa3f Target Port SAS Address: 5000c5000bae36c5 Type: SAS Device HBA Port Name: /dev/cfg/c7 Expander Device SAS Address: 500e004aaaaaaa3f HBA Port Name: /dev/cfg/c5 Expander Device SAS Address: 500e004aaaaaaa3f
Example 12 Listing Target Ports with SCSI Information
The following command lists all target port details, including SCSI information for each target port.
# sasinfo target-port -s 5000c5000bae4009 Target Port SAS Address: 5000c5000bae4009 Type: SAS Device HBA Port Name: /dev/cfg/c7 Expander Device SAS Address: 500e004aaaaaaa3f LUN : 0 OS Device Name : /dev/rdsk/c6t5000C5000BAE400Bd0s2 Vendor: Sun Product: J4400 Device Type: Disk HBA Port Name: /dev/cfg/c5 Expander Device SAS Address: 500e004aaaaaaa3f LUN : 0 OS Device Name : /dev/rdsk/c6t5000C5000BAE400Bd0s2 Vendor: Sun Product: J4400 Device Type: Disk
Example 13 Listing the Logical Units
The following command lists the logical units on a host.
# sasinfo logical-unit OS Device Name: /dev/rdsk/c4t50020F2300B4904Ed0s2 OS Device Name: /dev/rdsk/c4t50020F230000B4AFd0s2
Example 14 Listing Additional Information on Logical Units
The following command displays additional logical unit information using the -v option for device /dev/rmt/On.
# sasinfo lu -v OS Device Name: /dev/rdsk/c4t50020F2300B4904Ed0s2 HBA Port Name: /dev/cfg/c1 Target Port SAS Address: 50020f2300b4904e LUN: 0 Vendor: Sun Product: J4400 Device Type: Disk OS Device Name: /dev/rdsk/c4t50020F230000B4AFd0s2 HBA Port Name: /dev/cfg/c1 Target Port SAS Address: 50020f230063100b LUN: 0 Vendor: Sun Product: J4400 Device Type: Disk
See attributes(7) for descriptions of the following attributes:
ATTRIBUTE TYPE ATTRIBUTE VALUE |
Interface Stability Committed |
attributes (7)