xref: /illumos-gate/usr/src/man/man8/inetadm.8 (revision 088c6f3f90c806c9ed1bdffa1b625233a27eb084)
te
Copyright (c) 2004, Sun Microsystems, Inc. All Rights Reserved
The contents of this file are subject to the terms of the Common Development and Distribution License (the "License"). You may not use this file except in compliance with the License.
You can obtain a copy of the license at usr/src/OPENSOLARIS.LICENSE or http://www.opensolaris.org/os/licensing. See the License for the specific language governing permissions and limitations under the License.
When distributing Covered Code, include this CDDL HEADER in each file and include the License file at usr/src/OPENSOLARIS.LICENSE. If applicable, add the following below this CDDL HEADER, with the fields enclosed by brackets "[]" replaced with your own identifying information: Portions Copyright [yyyy] [name of copyright owner]
INETADM 8 "April 9, 2016"
NAME
inetadm - observe or configure inetd-controlled services
SYNOPSIS

inetadm

inetadm -?

inetadm -p

inetadm -l {FMRI | pattern}

inetadm -e {FMRI | pattern}

inetadm -d {FMRI | pattern}

inetadm -m {FMRI | pattern}... {name=value}...

inetadm -M {name=value}...
DESCRIPTION

The inetadm utility provides the following capabilities for inetd-managed SMF services:

Provides a list of all such services installed.

Lists the services' properties and values.

Allows enabling and disabling of services.

Allows modification of the services'property values, as well as the default values provided by inetd.

See smf(7) for a description of an SMF service.

With no arguments, inetadm lists all services under inetd(8) control, including such attributes as their current run state and whether or not they are enabled.

OPTIONS

For options taking one or more FMRI operands (see smf(7) for a description of an FMRI), if the operand specifies a service (instead of a service instance), and that service has only a single instance, inetadm operates on that instance.

If a service name is supplied and it contains more than one instance or a pattern is supplied and it matches more than one instance, a warning message is displayed and that operand is ignored.

For those options taking name=value parameters, a description of each of the possible names and the allowed values is found in the inetd(8) man page.

The following options are supported: -?

Display a usage message.

-p

Lists all default inet service property values provided by inetd in the form of name=value pairs. If the value is of boolean type, it is listed as TRUE or FALSE.

-l {FMRI | pattern}...

List all properties for the specified service instances as name=value pairs. In addition, if the property value is inherited from the default value provided by inetd, the name=value pair is identified by the token (default). Property inheritance occurs when properties do not have a specified service instance default.

-e {FMRI | pattern}...

Enable the specified service instances.

-d {FMRI | pattern}...

Disable the specified service instances.

-m {FMRI | pattern}...{name=value}...

Change the values of the specified properties of the identified service instances. Properties are specified as whitespace-separated name=value pairs. To remove an instance-specific value and accept the default value for a property, simply specify the property without a value, for example, name= .

-M {name=value}...

Change the values of the specified inetd default properties. Properties are specified as whitespace-separated name=value pairs.

EXAMPLES

Example 1 Displaying Properties for a Service

The following command displays the properties for the spray service.

# inetadm -l network/rpc/spray:default
SCOPE NAME=VALUE
 name="sprayd"
 endpoint_type="tli"
 proto="datagram_v"
 isrpc=TRUE
 rpc_low_version=1
 rpc_high_version=1
 wait=TRUE
 exec="/usr/lib/netsvc/spray/rpc.sprayd"
 user="root"
default bind_addr=""
default bind_fail_max=-1
default bind_fail_interval=-1
default max_con_rate=-1
default max_copies=-1
default con_rate_offline=-1
default failrate_cnt=40
default failrate_interval=60
default inherit_env=TRUE
default tcp_trace=FALSE
default tcp_wrappers=FALSE
default connection_backlog=10

Example 2 Displaying Default Properties

The following command displays default properties.

# inetadm -p
NAME=VALUE
bind_addr=""
bind_fail_max=-1
bind_fail_interval=-1
max_con_rate=-1
max_copies=-1
con_rate_offline=-1
failrate_cnt=40
failrate_interval=60
inherit_env=TRUE
tcp_trace=FALSE
tcp_wrappers=FALSE
default connection_backlog=10

Example 3 Changing Property Values for a Service

The following command changes rpc_high_version to 3 and tcp_trace to TRUE for the spray service.

# inetadm -m network/rpc/spray:default \e
 rpc_high_version=3 tcp_trace=TRUE
# inetadm -l network/rpc/spray:default
SCOPE NAME=VALUE
 name="sprayd"
 endpoint_type="tli"
 proto="datagram_v"
 isrpc=TRUE
 rpc_low_version=1
 rpc_high_version=3
 wait=TRUE
 exec="/usr/lib/netsvc/spray/rpc.sprayd"
 user="root"
default bind_addr=""
default bind_fail_max=-1
default bind_fail_interval=-1
default max_con_rate=-1
default max_copies=-1
default con_rate_offline=-1
default failrate_cnt=40
default failrate_interval=60
default inherit_env=TRUE
 tcp_trace=TRUE
default tcp_wrappers=FALSE
default connection_backlog=10
EXIT STATUS

The following exit values are returned: 0

Operation completed successfully.

1

A fatal error occurred. An accompanying error message will provide further information.

2

Invalid arguments were supplied, such as an ambiguous service FMRI or pattern.

ATTRIBUTES

See attributes(7) for descriptions of the following attributes:

ATTRIBUTE TYPE ATTRIBUTE VALUE
Interface Stability Evolving
SEE ALSO

attributes (7), smf (7), inetd (8), svccfg (8)