1#!/bin/sh 2# 3# CDDL HEADER START 4# 5# The contents of this file are subject to the terms of the 6# Common Development and Distribution License (the "License"). 7# You may not use this file except in compliance with the License. 8# 9# You can obtain a copy of the license at usr/src/OPENSOLARIS.LICENSE 10# or http://www.opensolaris.org/os/licensing. 11# See the License for the specific language governing permissions 12# and limitations under the License. 13# 14# When distributing Covered Code, include this CDDL HEADER in each 15# file and include the License file at usr/src/OPENSOLARIS.LICENSE. 16# If applicable, add the following below this CDDL HEADER, with the 17# fields enclosed by brackets "[]" replaced with your own identifying 18# information: Portions Copyright [yyyy] [name of copyright owner] 19# 20# CDDL HEADER END 21# 22# 23# Copyright 2007 Sun Microsystems, Inc. All rights reserved. 24# Use is subject to license terms. 25 26# 27# ident "%Z%%M% %I% %E% SMI" 28 29. /lib/svc/share/smf_include.sh 30 31METHOD=${1} 32INSTANCE=${2} 33 34DBUS_DESTINATION="org.freedesktop.Hal" 35MESSAGE_PREFIX="org.freedesktop.Hal.Device.NetworkDiscovery" 36OBJECT_PATH="/org/freedesktop/Hal/devices/network_attached" 37SMF_PROPERTY_GROUP="config" 38HAL_PROPERTY_GROUP="network_discovery" 39SVCS=/usr/bin/svcs 40 41usage() { 42 echo "Usage: $0 { start | stop | refresh } { snmp }" 43 exit $SMF_EXIT_ERR_FATAL 44} 45 46execute() { 47 echo "$*" 48 $* 49 50 return $? 51} 52 53start_snmp() { 54 interval=`/bin/svcprop -p config/interval ${SMF_FMRI} 2>/dev/null` 55 community=`/bin/svcprop -p config/community ${SMF_FMRI} 2>/dev/null` 56 network=`/bin/svcprop -p config/network ${SMF_FMRI} 2>/dev/null` 57 MESSAGE="${MESSAGE_PREFIX}.EnablePrinterScanningViaSNMP" 58 MESSAGE="${MESSAGE} int32:${interval:-60}" 59 MESSAGE="${MESSAGE} string:${community:-public}" 60 MESSAGE="${MESSAGE} string:${network:-0.0.0.0}" 61 62 execute /usr/bin/dbus-send --system --print-reply \ 63 --dest=${DBUS_DESTINATION} --type=method_call ${OBJECT_PATH} \ 64 ${MESSAGE} 65 return $? 66} 67 68stop_snmp() { 69 MESSAGE="${MESSAGE_PREFIX}.DisablePrinterScanningViaSNMP" 70 71 execute /usr/bin/dbus-send --system --print-reply \ 72 --dest=${DBUS_DESTINATION} --type=method_call ${OBJECT_PATH} \ 73 ${MESSAGE} 74 return $? 75} 76 77refresh_snmp() { 78 community=`/bin/svcprop -p config/community ${SMF_FMRI} 2>/dev/null` 79 network=`/bin/svcprop -p config/network ${SMF_FMRI} 2>/dev/null` 80 MESSAGE="${MESSAGE_PREFIX}.EnablePrinterScanningViaSNMP" 81 MESSAGE="${MESSAGE} string:${community:-public}" 82 MESSAGE="${MESSAGE} string:${network:-0.0.0.0}" 83 84 execute /usr/bin/dbus-send --system --print-reply \ 85 --dest=${DBUS_DESTINATION} --type=method_call ${OBJECT_PATH} \ 86 ${MESSAGE} 87 return $? 88} 89 90case "${METHOD}" in 91 'start') 92 ;; 93 'stop') 94 count=`$SVCS -o STATE hal 2>>/dev/null | grep -c "^online"` 95 if [ $count -eq 0 ] ; then 96 exit 0 # if HAL isn't running, there is nothing to do 97 fi 98 ;; 99 'refresh') 100 ;; 101 *) 102 usage 103 ;; 104esac 105 106case "${INSTANCE}" in 107 'snmp') 108 ;; 109 *) 110 usage 111 ;; 112esac 113 114${METHOD}_${INSTANCE} 115exit_code=$? 116 117exit $exit_code 118