xref: /illumos-gate/usr/src/cmd/fm/eversholt/files/common/storage.esc (revision 8d0c3d29bb99f6521f2dc5058a7e4debebad7899)
1/*
2 * CDDL HEADER START
3 *
4 * The contents of this file are subject to the terms of the
5 * Common Development and Distribution License (the "License").
6 * You may not use this file except in compliance with the License.
7 *
8 * You can obtain a copy of the license at usr/src/OPENSOLARIS.LICENSE
9 * or http://www.opensolaris.org/os/licensing.
10 * See the License for the specific language governing permissions
11 * and limitations under the License.
12 *
13 * When distributing Covered Code, include this CDDL HEADER in each
14 * file and include the License file at usr/src/OPENSOLARIS.LICENSE.
15 * If applicable, add the following below this CDDL HEADER, with the
16 * fields enclosed by brackets "[]" replaced with your own identifying
17 * information: Portions Copyright [yyyy] [name of copyright owner]
18 *
19 * CDDL HEADER END
20 */
21
22/*
23 * Copyright (c) 2010, Oracle and/or its affiliates. All rights reserved.
24 */
25
26#pragma dictionary "STORAGE"
27
28/*
29 * Fault event definitions.
30 */
31
32event fault.config.fan-fail@ses-enclosure;
33event fault.config.psu-fail@ses-enclosure;
34event fault.device.controller.fail@controller;
35event fault.device.ethernet.fail@controller;
36event fault.device.ethernet.fail@sas-expander;
37event fault.device.fan.fail@fan;
38event fault.device.fan.fail@fanmodule;
39event fault.device.psu.fail@psu;
40event fault.device.psu.fail@psu;
41event fault.device.sas-expander.fail@sas-expander;
42event fault.device.unusable-chassis-id@fanboard;
43event fault.io.i2c.fail@controller;
44event fault.io.i2c.fail@fanboard;
45event fault.io.i2c.fail@fanmodule;
46event fault.io.i2c.fail@powerboard;
47event fault.io.i2c.fail@psu;
48event fault.io.i2c.poweron-fail@controller;
49event fault.io.i2c.poweron-fail@fanboard;
50event fault.io.i2c.poweron-fail@fanmodule;
51event fault.io.i2c.poweron-fail@powerboard;
52event fault.io.i2c.poweron-fail@psu;
53event fault.io.sas.log.fatal@sas-expander;
54event fault.io.sas.log.non-fatal@sas-expander;
55event fault.power.ext-fail@ses-enclosure;
56event fault.power.fail@controller;
57event fault.power.fail@controller;
58event fault.power.fail@controller;
59event fault.power.fail@fanmodule;
60event fault.power.fail@fanmodule;
61event fault.power.fail@psu;
62event fault.power.fail@psu;
63event fault.sensor.read-fail@controller;
64event fault.sensor.read-fail@fanmodule;
65event fault.sensor.read-fail@fan;
66event fault.sensor.read-fail@psu;
67event fault.sp.fail@controller;
68event fault.sp.svc-fail@controller;
69event fault.sp.unavailable@controller;
70event fault.temp.fail@controller;
71event fault.temp.fail@fanmodule;
72event fault.temp.fail@psu;
73
74/*
75 * Error event definitions.
76 */
77
78event ereport.chassis.config.missing-fan@ses-enclosure;
79event ereport.chassis.config.missing-psu@ses-enclosure;
80event ereport.chassis.device.ecb.shutoff@controller;
81event ereport.chassis.device.ethernet.link-down@controller;
82event ereport.chassis.device.ethernet.link-down@sas-expander;
83event ereport.chassis.device.psu.dc-fail@psu;
84event ereport.chassis.device.psu.dc-oc@psu;
85event ereport.chassis.device.psu.dc-ov@psu;
86event ereport.chassis.device.psu.dc-uv@psu;
87event ereport.chassis.device.psu.ext-ac-fail@psu;
88event ereport.chassis.device.psu.ot@psu;
89event ereport.chassis.device.sas-expander.fail@sas-expander;
90event ereport.chassis.device.unusable-chassis-id@fanboard;
91event ereport.chassis.io.i2c.fail@controller;
92event ereport.chassis.io.i2c.fail@fanboard;
93event ereport.chassis.io.i2c.fail@fanmodule;
94event ereport.chassis.io.i2c.fail@powerboard;
95event ereport.chassis.io.i2c.fail@psu;
96event ereport.chassis.io.i2c.poweron-fail@controller;
97event ereport.chassis.io.i2c.poweron-fail@fanboard;
98event ereport.chassis.io.i2c.poweron-fail@fanmodule;
99event ereport.chassis.io.i2c.poweron-fail@powerboard;
100event ereport.chassis.io.i2c.poweron-fail@psu;
101event ereport.chassis.post.device.fail@controller;
102event ereport.chassis.post.device.fail@fan;
103event ereport.chassis.post.device.fail@fanmodule;
104event ereport.chassis.post.device.fail@psu;
105event ereport.chassis.post.sp.fail@controller;
106event ereport.chassis.sensor.current.oc@controller;
107event ereport.chassis.sensor.current.oc@fanmodule;
108event ereport.chassis.sensor.current.oc@psu;
109event ereport.chassis.sensor.current.uc@controller;
110event ereport.chassis.sensor.current.uc@fanmodule;
111event ereport.chassis.sensor.current.uc@psu;
112event ereport.chassis.sensor.fanspeed.us@fan;
113event ereport.chassis.sensor.read-fail@controller;
114event ereport.chassis.sensor.read-fail@fanmodule;
115event ereport.chassis.sensor.read-fail@fan;
116event ereport.chassis.sensor.read-fail@psu;
117event ereport.chassis.sensor.temp.ot@controller;
118event ereport.chassis.sensor.temp.ot@fanmodule;
119event ereport.chassis.sensor.temp.ot@psu;
120event ereport.chassis.sensor.temp.ut@controller;
121event ereport.chassis.sensor.temp.ut@fanmodule;
122event ereport.chassis.sensor.temp.ut@psu;
123event ereport.chassis.sensor.voltage.ov@controller;
124event ereport.chassis.sensor.voltage.ov@fanmodule;
125event ereport.chassis.sensor.voltage.ov@psu;
126event ereport.chassis.sensor.voltage.uv@controller;
127event ereport.chassis.sensor.voltage.uv@fanmodule;
128event ereport.chassis.sensor.voltage.uv@psu;
129event ereport.chassis.sp.svc-restart@controller;
130event ereport.chassis.sp.unavailable@controller;
131event ereport.io.sas.log.fatal@sas-expander;
132event ereport.io.sas.log.non-fatal@sas-expander;
133
134/*
135 * Service Processor failure
136 */
137
138prop fault.sp.fail@controller ->
139    ereport.chassis.post.sp.fail@controller;
140
141/*
142 * Controller failure
143 */
144
145prop fault.device.controller.fail@controller ->
146    ereport.chassis.post.device.fail@controller;
147
148/*
149 * Fan module failure
150 */
151
152prop fault.device.fan.fail@fanmodule ->
153    ereport.chassis.post.device.fail@fanmodule;
154
155/*
156 * I2C transaction failure
157 */
158
159prop fault.io.i2c.fail@controller ->
160    ereport.chassis.io.i2c.fail@controller;
161
162prop fault.io.i2c.fail@fanboard ->
163    ereport.chassis.io.i2c.fail@fanboard;
164
165prop fault.io.i2c.fail@fanmodule ->
166    ereport.chassis.io.i2c.fail@fanmodule;
167
168prop fault.io.i2c.fail@powerboard ->
169    ereport.chassis.io.i2c.fail@powerboard;
170
171prop fault.io.i2c.fail@psu ->
172    ereport.chassis.io.i2c.fail@psu;
173
174/*
175 * I2C transaction failure during power-on
176 */
177
178prop fault.io.i2c.poweron-fail@controller ->
179    ereport.chassis.io.i2c.poweron-fail@controller;
180
181prop fault.io.i2c.poweron-fail@fanboard ->
182    ereport.chassis.io.i2c.poweron-fail@fanboard;
183
184prop fault.io.i2c.poweron-fail@fanmodule ->
185    ereport.chassis.io.i2c.poweron-fail@fanmodule;
186
187prop fault.io.i2c.poweron-fail@powerboard ->
188    ereport.chassis.io.i2c.poweron-fail@powerboard;
189
190prop fault.io.i2c.poweron-fail@psu ->
191    ereport.chassis.io.i2c.poweron-fail@psu;
192
193/*
194 * Chassis ID unusable failure
195 */
196
197prop fault.device.unusable-chassis-id@fanboard ->
198    ereport.chassis.device.unusable-chassis-id@fanboard;
199
200/*
201 * Configuration failure
202 */
203
204prop fault.config.psu-fail@ses-enclosure ->
205    ereport.chassis.config.missing-psu@ses-enclosure;
206
207prop fault.config.fan-fail@ses-enclosure ->
208    ereport.chassis.config.missing-fan@ses-enclosure;
209
210/*
211 * Fan failure
212 */
213
214prop fault.device.fan.fail@fan ->
215    ereport.chassis.sensor.fanspeed.us@fan,
216    ereport.chassis.post.device.fail@fan;
217
218/*
219 * Sensor reading failure
220 */
221
222prop fault.sensor.read-fail@controller ->
223    ereport.chassis.sensor.read-fail@controller;
224
225prop fault.sensor.read-fail@fanmodule ->
226    ereport.chassis.sensor.read-fail@fanmodule;
227
228prop fault.sensor.read-fail@fan ->
229    ereport.chassis.sensor.read-fail@fan;
230
231prop fault.sensor.read-fail@psu ->
232    ereport.chassis.sensor.read-fail@psu;
233
234/*
235 * Temperature failure
236 */
237
238prop fault.temp.fail@controller ->
239    ereport.chassis.sensor.temp.ot@controller,
240    ereport.chassis.sensor.temp.ut@controller;
241
242prop fault.temp.fail@fanmodule ->
243    ereport.chassis.sensor.temp.ot@fanmodule,
244    ereport.chassis.sensor.temp.ut@fanmodule;
245
246prop fault.temp.fail@psu ->
247    ereport.chassis.sensor.temp.ot@psu,
248    ereport.chassis.sensor.temp.ut@psu;
249
250/*
251 * Power failure
252 */
253
254prop fault.power.fail@controller ->
255    ereport.chassis.device.ecb.shutoff@controller,
256    ereport.chassis.sensor.current.oc@controller,
257    ereport.chassis.sensor.current.uc@controller,
258    ereport.chassis.sensor.voltage.ov@controller,
259    ereport.chassis.sensor.voltage.uv@controller;
260
261prop fault.power.fail@fanmodule ->
262    ereport.chassis.sensor.current.oc@fanmodule,
263    ereport.chassis.sensor.current.uc@fanmodule,
264    ereport.chassis.sensor.voltage.ov@fanmodule,
265    ereport.chassis.sensor.voltage.uv@fanmodule;
266
267prop fault.power.fail@psu ->
268    ereport.chassis.sensor.current.oc@psu,
269    ereport.chassis.sensor.current.uc@psu,
270    ereport.chassis.sensor.voltage.ov@psu,
271    ereport.chassis.sensor.voltage.uv@psu;
272
273/*
274 * Power supply unit failure
275 */
276
277prop fault.device.psu.fail@psu ->
278    ereport.chassis.device.psu.dc-fail@psu,
279    ereport.chassis.device.psu.dc-ov@psu,
280    ereport.chassis.device.psu.dc-uv@psu,
281    ereport.chassis.device.psu.dc-oc@psu,
282    ereport.chassis.device.psu.ot@psu,
283    ereport.chassis.post.device.fail@psu;
284
285/*
286 * External power failure
287 */
288
289prop fault.power.ext-fail@ses-enclosure ->
290    ereport.chassis.device.psu.ext-ac-fail@psu<>;
291
292/*
293 * SAS Expander failure
294 */
295
296prop fault.device.sas-expander.fail@sas-expander ->
297    ereport.chassis.device.sas-expander.fail@sas-expander;
298
299/*
300 * Ethernet failure
301 */
302
303prop fault.device.ethernet.fail@controller ->
304    ereport.chassis.device.ethernet.link-down@controller;
305
306prop fault.device.ethernet.fail@sas-expander ->
307    ereport.chassis.device.ethernet.link-down@sas-expander;
308
309/*
310 * Service Processor unavailable failure
311 */
312
313prop fault.sp.unavailable@controller ->
314    ereport.chassis.sp.unavailable@controller;
315
316/*
317 * Service Processor service failure
318 */
319
320prop fault.sp.svc-fail@controller ->
321    ereport.chassis.sp.svc-restart@controller;
322
323/*
324 * SAS Expander Log failure
325 */
326
327prop fault.io.sas.log.non-fatal@sas-expander ->
328    ereport.io.sas.log.non-fatal@sas-expander;
329
330prop fault.io.sas.log.fatal@sas-expander ->
331    ereport.io.sas.log.fatal@sas-expander;
332