1# 2# Copyright (c) 2010, Oracle and/or its affiliates. All rights reserved. 3# 4# CDDL HEADER START 5# 6# The contents of this file are subject to the terms of the 7# Common Development and Distribution License (the "License"). 8# You may not use this file except in compliance with the License. 9# 10# You can obtain a copy of the license at usr/src/OPENSOLARIS.LICENSE 11# or http://www.opensolaris.org/os/licensing. 12# See the License for the specific language governing permissions 13# and limitations under the License. 14# 15# When distributing Covered Code, include this CDDL HEADER in each 16# file and include the License file at usr/src/OPENSOLARIS.LICENSE. 17# If applicable, add the following below this CDDL HEADER, with the 18# fields enclosed by brackets "[]" replaced with your own identifying 19# information: Portions Copyright [yyyy] [name of copyright owner] 20# 21# CDDL HEADER END 22# 23 24# DO NOT EDIT -- this file is generated by the Event Registry. 25# 26# 27# code: SUNOS-8000-0G 28# keys: ereport.sunos.unix.fm_panic 29# 30msgid "SUNOS-8000-0G.type" 31msgstr "Error" 32msgid "SUNOS-8000-0G.severity" 33msgstr "Major" 34msgid "SUNOS-8000-0G.description" 35msgstr "Errors have been detected that require a reboot to ensure system integrity. Refer to %s for more information." 36msgid "SUNOS-8000-0G.response" 37msgstr "Solaris will attempt to save and diagnose the error telemetry" 38msgid "SUNOS-8000-0G.impact" 39msgstr "The system will sync files, save a crash dump if needed, and reboot" 40msgid "SUNOS-8000-0G.action" 41msgstr "Save the error summary below in case telemetry cannot be saved" 42# 43# code: SUNOS-8000-1L 44# keys: defect.sunos.eft.undiagnosable_problem 45# 46msgid "SUNOS-8000-1L.type" 47msgstr "Defect" 48msgid "SUNOS-8000-1L.severity" 49msgstr "Minor" 50msgid "SUNOS-8000-1L.description" 51msgstr "The EFT Diagnosis Engine encountered telemetry for which it is unable to produce a diagnosis. Refer to %s for more information." 52msgid "SUNOS-8000-1L.response" 53msgstr "Error reports from the component will be logged for examination by Sun." 54msgid "SUNOS-8000-1L.impact" 55msgstr "Automated diagnosis and response for these events will not occur." 56msgid "SUNOS-8000-1L.action" 57msgstr "Run pkgchk -n SUNWfmd to ensure that fault management software is installed properly. Contact Sun for support." 58# 59# code: SUNOS-8000-20 60# keys: defect.Deprecated defect.io.pci.driver fault.io.pci.bus fault.io.pci.device 61# 62msgid "SUNOS-8000-20.type" 63msgstr "Fault" 64msgid "SUNOS-8000-20.severity" 65msgstr "Critical" 66msgid "SUNOS-8000-20.description" 67msgstr "A problem was detected in the SUNOS subsystem or controlling software. Refer to %s for more information." 68msgid "SUNOS-8000-20.response" 69msgstr "One or more of device instances may be disabled" 70msgid "SUNOS-8000-20.impact" 71msgstr "Loss of services provided by the device instances associated with this fault" 72msgid "SUNOS-8000-20.action" 73msgstr "Ensure latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support." 74# 75# code: SUNOS-8000-3V 76# keys: defect.Deprecated fault.io.pci.bus fault.io.pci.device 77# 78msgid "SUNOS-8000-3V.type" 79msgstr "Fault" 80msgid "SUNOS-8000-3V.severity" 81msgstr "Critical" 82msgid "SUNOS-8000-3V.description" 83msgstr "A problem was detected in the PCI subsystem. Refer to %s for more information." 84msgid "SUNOS-8000-3V.response" 85msgstr "One or more of device instances may be disabled" 86msgid "SUNOS-8000-3V.impact" 87msgstr "Loss of services provided by the device instances associated with this fault" 88msgid "SUNOS-8000-3V.action" 89msgstr "Schedule a repair procedure to replace the affected device. Use fmdump -v -u <EVENT_ID> to identify the device or contact Sun for support." 90# 91# code: SUNOS-8000-46 92# keys: defect.Deprecated defect.io.pci.driver fault.io.pci.device 93# 94msgid "SUNOS-8000-46.type" 95msgstr "Fault" 96msgid "SUNOS-8000-46.severity" 97msgstr "Critical" 98msgid "SUNOS-8000-46.description" 99msgstr "A problem was detected in the PCI subsystem or controlling software. Refer to %s for more information." 100msgid "SUNOS-8000-46.response" 101msgstr "One or more of device instances may be disabled" 102msgid "SUNOS-8000-46.impact" 103msgstr "Loss of services provided by the device instances associated with this fault" 104msgid "SUNOS-8000-46.action" 105msgstr "Ensure latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support." 106# 107# code: SUNOS-8000-5T 108# keys: defect.Deprecated defect.io.pci.driver fault.io.pci.bus 109# 110msgid "SUNOS-8000-5T.type" 111msgstr "Fault" 112msgid "SUNOS-8000-5T.severity" 113msgstr "Critical" 114msgid "SUNOS-8000-5T.description" 115msgstr "A problem was detected in the PCI subsystem or controlling software. Refer to %s for more information." 116msgid "SUNOS-8000-5T.response" 117msgstr "One or more of device instances may be disabled" 118msgid "SUNOS-8000-5T.impact" 119msgstr "Loss of services provided by the device instances associated with this fault" 120msgid "SUNOS-8000-5T.action" 121msgstr "Ensure latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support." 122# 123# code: SUNOS-8000-69 124# keys: defect.Deprecated fault.io.pci.device 125# 126msgid "SUNOS-8000-69.type" 127msgstr "Fault" 128msgid "SUNOS-8000-69.severity" 129msgstr "Critical" 130msgid "SUNOS-8000-69.description" 131msgstr "A problem was detected for a PCI controller Refer to %s for more information." 132msgid "SUNOS-8000-69.response" 133msgstr "One or more of device instances may be disabled" 134msgid "SUNOS-8000-69.impact" 135msgstr "Loss of services provided by the device instances associated with this fault." 136msgid "SUNOS-8000-69.action" 137msgstr "Schedule a repair procedure to replace the affected device. Use fmdump -v -u <EVENT_ID> to identify the device or contact Sun for support." 138# 139# code: SUNOS-8000-7N 140# keys: defect.Deprecated fault.io.pci.bus 141# 142msgid "SUNOS-8000-7N.type" 143msgstr "Fault" 144msgid "SUNOS-8000-7N.severity" 145msgstr "Critical" 146msgid "SUNOS-8000-7N.description" 147msgstr "A problem was detected for a PCI bus Refer to %s for more information." 148msgid "SUNOS-8000-7N.response" 149msgstr "One or more of device instances may be disabled" 150msgid "SUNOS-8000-7N.impact" 151msgstr "Loss of services provided by the device instances associated with this fault." 152msgid "SUNOS-8000-7N.action" 153msgstr "Schedule a repair procedure to replace the affected device. Use fmdump -v -u <EVENT_ID> to identify the device or contact Sun for support." 154# 155# code: SUNOS-8000-8W 156# keys: defect.Deprecated defect.io.pci.driver 157# 158msgid "SUNOS-8000-8W.type" 159msgstr "Fault" 160msgid "SUNOS-8000-8W.severity" 161msgstr "Critical" 162msgid "SUNOS-8000-8W.description" 163msgstr "A problem was detected in the PCI controller software Refer to %s for more information." 164msgid "SUNOS-8000-8W.response" 165msgstr "One or more of device instances may be disabled" 166msgid "SUNOS-8000-8W.impact" 167msgstr "Loss of services provided by the device instances associated with this fault." 168msgid "SUNOS-8000-8W.action" 169msgstr "Ensure latest drivers and patches are installed. Use fmdump -v -u <EVENT_ID> to identify the module/package, or contact Sun for support." 170# 171# code: SUNOS-8000-91 172# keys: defect.sunos.zones.upgrade 173# 174msgid "SUNOS-8000-91.type" 175msgstr "Defect" 176msgid "SUNOS-8000-91.severity" 177msgstr "Minor" 178msgid "SUNOS-8000-91.description" 179msgstr "\n The Solaris system or boot environment that is being upgraded\n has non-global zones installed. The current version of Live\n Upgrade cannot upgrade a boot environment that has non-global\n zones installed.\n Refer to %s for more information." 180msgid "SUNOS-8000-91.response" 181msgstr "The upgrade procedure has been terminated." 182msgid "SUNOS-8000-91.impact" 183msgstr "The Solaris system or boot environment is not upgraded." 184msgid "SUNOS-8000-91.action" 185msgstr "\n Evaluate each of the choices below and select the one that is\n best for your needs. Contact Sun for support.\n " 186# 187# code: SUNOS-8000-AK 188# keys: ereport.sunos.boot.upgrade.menu_lst 189# 190msgid "SUNOS-8000-AK.type" 191msgstr "Error" 192msgid "SUNOS-8000-AK.severity" 193msgstr "Critical" 194msgid "SUNOS-8000-AK.description" 195msgstr "Solaris OS could not automatically adjust\n/boot/grub/menu.lst\nto the new boot architecture\n Refer to %s for more information." 196msgid "SUNOS-8000-AK.response" 197msgstr "No automated response." 198msgid "SUNOS-8000-AK.impact" 199msgstr "Future reboots could fail until this problem is corrected." 200msgid "SUNOS-8000-AK.action" 201msgstr "Examine /boot/grub/menu.lst and revise as\ndescribed in Details." 202# 203# code: SUNOS-8000-CF 204# keys: ereport.sunos.boot.upgrade.menu_lst_bfu 205# 206msgid "SUNOS-8000-CF.type" 207msgstr "Error" 208msgid "SUNOS-8000-CF.severity" 209msgstr "Critical" 210msgid "SUNOS-8000-CF.description" 211msgstr "Solaris OS could not automatically adjust\n/boot/grub/menu.lst\nto the new boot architecture\n Refer to %s for more information." 212msgid "SUNOS-8000-CF.response" 213msgstr "No automated response." 214msgid "SUNOS-8000-CF.impact" 215msgstr "Future reboots could fail until this problem is corrected." 216msgid "SUNOS-8000-CF.action" 217msgstr "Examine /boot/grub/menu.lst and revise as\ndescribed in Details." 218# 219# code: SUNOS-8000-DM 220# keys: defect.sunos.smf.svc.maintenance 221# 222msgid "SUNOS-8000-DM.type" 223msgstr "Defect" 224msgid "SUNOS-8000-DM.severity" 225msgstr "Major" 226msgid "SUNOS-8000-DM.description" 227msgstr "A service failed and could not be restarted. Refer to %s for more information." 228msgid "SUNOS-8000-DM.response" 229msgstr "The service has been placed into the maintenance state." 230msgid "SUNOS-8000-DM.impact" 231msgstr "The service is unavailable." 232msgid "SUNOS-8000-DM.action" 233msgstr "Run 'svcs -x' to determine why the service failed and the location of logfiles, if any." 234# 235# code: SUNOS-8000-E8 236# keys: defect.sunos.eft.undiag.checkpoint 237# 238msgid "SUNOS-8000-E8.type" 239msgstr "Defect" 240msgid "SUNOS-8000-E8.severity" 241msgstr "Minor" 242msgid "SUNOS-8000-E8.description" 243msgstr "The diagnosis engine encountered an error while resuming diagnosis. Refer to %s for more information." 244msgid "SUNOS-8000-E8.response" 245msgstr "Error reports have been logged for examination by Sun." 246msgid "SUNOS-8000-E8.impact" 247msgstr "Automated diagnosis and response for these events will not occur." 248msgid "SUNOS-8000-E8.action" 249msgstr "Remove the diagnosis engine checkpoint file '/var/fm/fmd/ckpt/eft/eft', repair this defect, and restart the fault manager." 250# 251# code: SUNOS-8000-FU 252# keys: defect.sunos.eft.undiag.fme 253# 254msgid "SUNOS-8000-FU.type" 255msgstr "Defect" 256msgid "SUNOS-8000-FU.severity" 257msgstr "Major" 258msgid "SUNOS-8000-FU.description" 259msgstr "The diagnosis engine encountered telemetry for which it was unable to perform a diagnosis. Refer to %s for more information." 260msgid "SUNOS-8000-FU.response" 261msgstr "Error reports have been logged for examination by Sun." 262msgid "SUNOS-8000-FU.impact" 263msgstr "Automated diagnosis and response for these events will not occur." 264msgid "SUNOS-8000-FU.action" 265msgstr "Ensure that the latest Solaris Kernel and Predictive Self-Healing (PSH) patches are installed." 266# 267# code: SUNOS-8000-G7 268# keys: defect.sunos.eft.undiag.limit 269# 270msgid "SUNOS-8000-G7.type" 271msgstr "Defect" 272msgid "SUNOS-8000-G7.severity" 273msgstr "Minor" 274msgid "SUNOS-8000-G7.description" 275msgstr "The diagnosis engine hit a limit restriction and was unable to perform a diagnosis. Refer to %s for more information." 276msgid "SUNOS-8000-G7.response" 277msgstr "Error reports have been logged for examination by Sun." 278msgid "SUNOS-8000-G7.impact" 279msgstr "Automated diagnosis and response for these events will not occur." 280msgid "SUNOS-8000-G7.action" 281msgstr "Check the diagnosis engine configuration file '/usr/lib/fm/fmd/plugins/eft.conf' and ensure that no limit restrictions are set, then repair this defect, and restart the fault manager." 282# 283# code: SUNOS-8000-HV 284# keys: defect.sunos.eft.undiag.unknown 285# 286msgid "SUNOS-8000-HV.type" 287msgstr "Defect" 288msgid "SUNOS-8000-HV.severity" 289msgstr "Minor" 290msgid "SUNOS-8000-HV.description" 291msgstr "The diagnosis engine encountered telemetry for which it was unable to perform a diagnosis. Refer to %s for more information." 292msgid "SUNOS-8000-HV.response" 293msgstr "Error reports have been logged for examination by Sun." 294msgid "SUNOS-8000-HV.impact" 295msgstr "Automated diagnosis and response for these events will not occur." 296msgid "SUNOS-8000-HV.action" 297msgstr "Ensure that the latest Solaris Kernel and Predictive Self-Healing (PSH) patches are installed." 298# 299# code: SUNOS-8000-J0 300# keys: defect.sunos.eft.unexpected_telemetry fault.sunos.eft.unexpected_telemetry 301# 302msgid "SUNOS-8000-J0.type" 303msgstr "Fault" 304msgid "SUNOS-8000-J0.severity" 305msgstr "Major" 306msgid "SUNOS-8000-J0.description" 307msgstr "The diagnosis engine encountered telemetry from the listed devices for which it was unable to perform a diagnosis - %.\n Refer to %s for more information. Refer to %s for more information." 308msgid "SUNOS-8000-J0.response" 309msgstr "Error reports have been logged for examination by Sun.\n" 310msgid "SUNOS-8000-J0.impact" 311msgstr "Automated diagnosis and response for these events will not occur.\n" 312msgid "SUNOS-8000-J0.action" 313msgstr "Ensure that the latest Solaris Kernel and Predictive Self-Healing (PSH) patches are installed.\n" 314# 315# code: SUNOS-8000-KL 316# keys: defect.sunos.kernel.panic 317# 318msgid "SUNOS-8000-KL.type" 319msgstr "Defect" 320msgid "SUNOS-8000-KL.severity" 321msgstr "Major" 322msgid "SUNOS-8000-KL.description" 323msgstr "The system has rebooted after a kernel panic. Refer to %s for more information." 324msgid "SUNOS-8000-KL.response" 325msgstr "The failed system image was dumped to the dump device. If savecore is enabled (see dumpadm(1M)) a copy of the dump will be written to the savecore directory %<fault-list[0].dump-dir>." 326msgid "SUNOS-8000-KL.impact" 327msgstr "There may be some performance impact while the panic is copied to the savecore directory. Disk space usage by panics can be substantial." 328msgid "SUNOS-8000-KL.action" 329msgstr "If savecore is not enabled then please take steps to preserve the crash image.\nUse 'fmdump -Vp -u %<uuid>' to view more panic detail. Please refer to the knowledge article for additional information." 330