xref: /illumos-gate/usr/src/cmd/fm/dicts/STORAGE.po (revision 6e0cbcaa0c6f2bc34634a4cc17b099f9ecef03d1)
1#
2# Copyright (c) 2010, Oracle and/or its affiliates. All rights reserved.
3#
4# CDDL HEADER START
5#
6# The contents of this file are subject to the terms of the
7# Common Development and Distribution License (the "License").
8# You may not use this file except in compliance with the License.
9#
10# You can obtain a copy of the license at usr/src/OPENSOLARIS.LICENSE
11# or http://www.opensolaris.org/os/licensing.
12# See the License for the specific language governing permissions
13# and limitations under the License.
14#
15# When distributing Covered Code, include this CDDL HEADER in each
16# file and include the License file at usr/src/OPENSOLARIS.LICENSE.
17# If applicable, add the following below this CDDL HEADER, with the
18# fields enclosed by brackets "[]" replaced with your own identifying
19# information: Portions Copyright [yyyy] [name of copyright owner]
20#
21# CDDL HEADER END
22#
23# DO NOT EDIT -- this file is generated by the Event Registry.
24#
25#
26# code: STORAGE-8000-1Q
27# keys: fault.config.fan-fail
28#
29msgid "STORAGE-8000-1Q.type"
30msgstr "Fault"
31msgid "STORAGE-8000-1Q.severity"
32msgstr "Critical"
33msgid "STORAGE-8000-1Q.description"
34msgstr "The minimum number of required fan trays (3) were not detected.\n"
35msgid "STORAGE-8000-1Q.response"
36msgstr "The service required LED on the enclosure will be illuminated.\n"
37msgid "STORAGE-8000-1Q.impact"
38msgstr "The SAS fabric is down, and user data storage is unavailable until the configuration problem is resolved.\n"
39msgid "STORAGE-8000-1Q.action"
40msgstr "Check that the minimum required number of components are configured.\n"
41#
42# code: STORAGE-8000-24
43# keys: fault.config.psu-fail
44#
45msgid "STORAGE-8000-24.type"
46msgstr "Fault"
47msgid "STORAGE-8000-24.severity"
48msgstr "Critical"
49msgid "STORAGE-8000-24.description"
50msgstr "The minimum number of required power supplies (3) were not detected.\n"
51msgid "STORAGE-8000-24.response"
52msgstr "The service required LED on the enclosure will be illuminated.\n"
53msgid "STORAGE-8000-24.impact"
54msgstr "The SAS fabric is down, and user data storage is unavailable until the configuration problem is resolved.\n"
55msgid "STORAGE-8000-24.action"
56msgstr "Check that the minimum required number of components are configured.\n"
57#
58# code: STORAGE-8000-3R
59# keys: fault.device.controller.fail
60#
61msgid "STORAGE-8000-3R.type"
62msgstr "Fault"
63msgid "STORAGE-8000-3R.severity"
64msgstr "Major"
65msgid "STORAGE-8000-3R.description"
66msgstr "A Controller failed.\n"
67msgid "STORAGE-8000-3R.response"
68msgstr "The service required LED on the enclosure will be illuminated.\n"
69msgid "STORAGE-8000-3R.impact"
70msgstr "The SAS fabric may be in a degraded state.\n"
71msgid "STORAGE-8000-3R.action"
72msgstr "Refer to the Maintenance page in the Sun ZFS Storage UI to identify the failed component. If a repair is required, the repair instructions are located in the Help section of the Sun ZFS Storage UI.\n"
73#
74# code: STORAGE-8000-42
75# keys: fault.device.ethernet.fail
76#
77msgid "STORAGE-8000-42.type"
78msgstr "Fault"
79msgid "STORAGE-8000-42.severity"
80msgstr "Major"
81msgid "STORAGE-8000-42.description"
82msgstr "An ethernet device failed.\n"
83msgid "STORAGE-8000-42.response"
84msgstr "The service required LED on the enclosure will be illuminated.\n"
85msgid "STORAGE-8000-42.impact"
86msgstr "The SAS fabric may be in a degraded state. User data storage is still available.\n"
87msgid "STORAGE-8000-42.action"
88msgstr "Refer to the Maintenance page in the Sun ZFS Storage UI to identify the failed component. If a repair is required, the repair instructions are located in the Help section of the Sun ZFS Storage UI.\n"
89#
90# code: STORAGE-8000-5X
91# keys: fault.device.fan.fail
92#
93msgid "STORAGE-8000-5X.type"
94msgstr "Fault"
95msgid "STORAGE-8000-5X.severity"
96msgstr "Major"
97msgid "STORAGE-8000-5X.description"
98msgstr "A fan is no longer operating correctly.\n"
99msgid "STORAGE-8000-5X.response"
100msgstr "The service required LED on the enclosure will be illuminated.\n"
101msgid "STORAGE-8000-5X.impact"
102msgstr "The enclosure may be getting inadequate cooling. If the problem persists, components may overheat and the enclosure may shutdown.\n"
103msgid "STORAGE-8000-5X.action"
104msgstr "Refer to the Maintenance page in the Sun ZFS Storage UI to identify the failed component. If a repair is required, the repair instructions are located in the Help section of the Sun ZFS Storage UI.\n"
105#
106# code: STORAGE-8000-6E
107# keys: fault.device.psu.fail
108#
109msgid "STORAGE-8000-6E.type"
110msgstr "Fault"
111msgid "STORAGE-8000-6E.severity"
112msgstr "Major"
113msgid "STORAGE-8000-6E.description"
114msgstr "A power supply is no longer operating correctly.\n"
115msgid "STORAGE-8000-6E.response"
116msgstr "The service required LED on the enclosure will be illuminated.\n"
117msgid "STORAGE-8000-6E.impact"
118msgstr "The enclosure may not be getting adequate power. Subsequent loss of power supplies may cause the enclosure to shutdown.\n"
119msgid "STORAGE-8000-6E.action"
120msgstr "Refer to the Maintenance page in the Sun ZFS Storage UI to identify the failed component. If a repair is required, the repair instructions are located in the Help section of the Sun ZFS Storage UI.\n"
121#
122# code: STORAGE-8000-7J
123# keys: fault.device.sas-expander.fail
124#
125msgid "STORAGE-8000-7J.type"
126msgstr "Fault"
127msgid "STORAGE-8000-7J.severity"
128msgstr "Major"
129msgid "STORAGE-8000-7J.description"
130msgstr "A SAS expander is not functioning properly.\n"
131msgid "STORAGE-8000-7J.response"
132msgstr "The service required LED on the enclosure will be illuminated.\n"
133msgid "STORAGE-8000-7J.impact"
134msgstr "The SAS fabric is in a degraded state. User data storage is still available.\n"
135msgid "STORAGE-8000-7J.action"
136msgstr "Refer to the Maintenance page in the Sun ZFS Storage UI to identify the failed component. If a repair is required, the repair instructions are located in the Help section of the Sun ZFS Storage UI.\n"
137#
138# code: STORAGE-8000-8S
139# keys: fault.device.unusable-chassis-id
140#
141msgid "STORAGE-8000-8S.type"
142msgstr "Fault"
143msgid "STORAGE-8000-8S.severity"
144msgstr "Critical"
145msgid "STORAGE-8000-8S.description"
146msgstr "The chassis ID was determined to be unusable.\n"
147msgid "STORAGE-8000-8S.response"
148msgstr "The service required LED on the enclosure will be illuminated.\n"
149msgid "STORAGE-8000-8S.impact"
150msgstr "The SAS fabric is down, and user data storage is unavailable.\n"
151msgid "STORAGE-8000-8S.action"
152msgstr "Refer to the Maintenance page in the Sun ZFS Storage UI to identify the failed component. If a repair is required, the repair instructions are located in the Help section of the Sun ZFS Storage UI.\n"
153#
154# code: STORAGE-8000-95
155# keys: fault.io.i2c.fail
156#
157msgid "STORAGE-8000-95.type"
158msgstr "Fault"
159msgid "STORAGE-8000-95.severity"
160msgstr "Critical"
161msgid "STORAGE-8000-95.description"
162msgstr "An I2C bus failure has occurred.\n"
163msgid "STORAGE-8000-95.response"
164msgstr "The service required LED on the enclosure will be illuminated.\n"
165msgid "STORAGE-8000-95.impact"
166msgstr "The system is in an unknown state.\n"
167msgid "STORAGE-8000-95.action"
168msgstr "Refer to the Maintenance page in the Sun ZFS Storage UI to identify the failed component. If a repair is required, the repair instructions are located in the Help section of the Sun ZFS Storage UI.\n"
169#
170# code: STORAGE-8000-AP
171# keys: fault.io.i2c.poweron-fail
172#
173msgid "STORAGE-8000-AP.type"
174msgstr "Fault"
175msgid "STORAGE-8000-AP.severity"
176msgstr "Critical"
177msgid "STORAGE-8000-AP.description"
178msgstr "An I2C bus failure has occurred during power-on.\n"
179msgid "STORAGE-8000-AP.response"
180msgstr "The service required LED on the enclosure will be illuminated.\n"
181msgid "STORAGE-8000-AP.impact"
182msgstr "The system is in an unknown state.\n"
183msgid "STORAGE-8000-AP.action"
184msgstr "Refer to the Maintenance page in the Sun ZFS Storage UI to identify the failed component. If a repair is required, the repair instructions are located in the Help section of the Sun ZFS Storage UI.\n"
185#
186# code: STORAGE-8000-CA
187# keys: fault.io.sas.log.non-fatal
188#
189msgid "STORAGE-8000-CA.type"
190msgstr "Fault"
191msgid "STORAGE-8000-CA.severity"
192msgstr "Major"
193msgid "STORAGE-8000-CA.description"
194msgstr "A SAS expander log failure has occurred.\n"
195msgid "STORAGE-8000-CA.response"
196msgstr "The service required LED on the enclosure will be illuminated.\n"
197msgid "STORAGE-8000-CA.impact"
198msgstr "The system is in an unknown state.\n"
199msgid "STORAGE-8000-CA.action"
200msgstr "Refer to the Maintenance page in the Sun ZFS Storage UI to identify the failed component. If a repair is required, the repair instructions are located in the Help section of the Sun ZFS Storage UI.\n"
201#
202# code: STORAGE-8000-DH
203# keys: fault.io.sas.log.fatal
204#
205msgid "STORAGE-8000-DH.type"
206msgstr "Fault"
207msgid "STORAGE-8000-DH.severity"
208msgstr "Critical"
209msgid "STORAGE-8000-DH.description"
210msgstr "A SAS expander log failure has occurred.\n"
211msgid "STORAGE-8000-DH.response"
212msgstr "The service required LED on the enclosure will be illuminated.\n"
213msgid "STORAGE-8000-DH.impact"
214msgstr "The system is in an unknown state.\n"
215msgid "STORAGE-8000-DH.action"
216msgstr "Refer to the Maintenance page in the Sun ZFS Storage UI to identify the failed component. If a repair is required, the repair instructions are located in the Help section of the Sun ZFS Storage UI.\n"
217#
218# code: STORAGE-8000-ED
219# keys: fault.power.fail
220#
221msgid "STORAGE-8000-ED.type"
222msgstr "Fault"
223msgid "STORAGE-8000-ED.severity"
224msgstr "Major"
225msgid "STORAGE-8000-ED.description"
226msgstr "A power failure has occurred.\n"
227msgid "STORAGE-8000-ED.response"
228msgstr "The service required LED on the enclosure will be illuminated.\n"
229msgid "STORAGE-8000-ED.impact"
230msgstr "A device in the enclosure may be getting inadequate power. Subsequent loss of the device may force the enclosure to shutdown.\n"
231msgid "STORAGE-8000-ED.action"
232msgstr "Refer to the Maintenance page in the Sun ZFS Storage UI to identify the failed component. If a repair is required, the repair instructions are located in the Help section of the Sun ZFS Storage UI.\n"
233#
234# code: STORAGE-8000-FY
235# keys: fault.power.ext-fail
236#
237msgid "STORAGE-8000-FY.type"
238msgstr "Fault"
239msgid "STORAGE-8000-FY.severity"
240msgstr "Major"
241msgid "STORAGE-8000-FY.description"
242msgstr "A power failure external to the enclosure has occurred.\n"
243msgid "STORAGE-8000-FY.response"
244msgstr "The service required LED on the enclosure will be illuminated.\n"
245msgid "STORAGE-8000-FY.impact"
246msgstr "The enclosure may not be getting adequate power. Subsequent loss of power supplies may cause the enclosure to shutdown.\n"
247msgid "STORAGE-8000-FY.action"
248msgstr "Check that external AC power is available and that all the power cords are properly plugged into the enclosure power supplies.\n"
249#
250# code: STORAGE-8000-G3
251# keys: fault.sensor.read-fail
252#
253msgid "STORAGE-8000-G3.type"
254msgstr "Fault"
255msgid "STORAGE-8000-G3.severity"
256msgstr "Major"
257msgid "STORAGE-8000-G3.description"
258msgstr "An attempt to read a sensor failed.\n"
259msgid "STORAGE-8000-G3.response"
260msgstr "The service required LED on the enclosure will be illuminated.\n"
261msgid "STORAGE-8000-G3.impact"
262msgstr "The system is in an unknown state.\n"
263msgid "STORAGE-8000-G3.action"
264msgstr "Refer to the Maintenance page in the Sun ZFS Storage UI to identify the failed component. If a repair is required, the repair instructions are located in the Help section of the Sun ZFS Storage UI.\n"
265#
266# code: STORAGE-8000-HR
267# keys: fault.sp.fail
268#
269msgid "STORAGE-8000-HR.type"
270msgstr "Fault"
271msgid "STORAGE-8000-HR.severity"
272msgstr "Critical"
273msgid "STORAGE-8000-HR.description"
274msgstr "A Service Processor failed.\n"
275msgid "STORAGE-8000-HR.response"
276msgstr "The service required LED on the enclosure will be illuminated.\n"
277msgid "STORAGE-8000-HR.impact"
278msgstr "The SAS fabric may be in a degraded state.\n"
279msgid "STORAGE-8000-HR.action"
280msgstr "Refer to the Maintenance page in the Sun ZFS Storage UI to identify the failed component. If a repair is required, the repair instructions are located in the Help section of the Sun ZFS Storage UI.\n"
281#
282# code: STORAGE-8000-J4
283# keys: fault.sp.unavailable
284#
285msgid "STORAGE-8000-J4.type"
286msgstr "Fault"
287msgid "STORAGE-8000-J4.severity"
288msgstr "Major"
289msgid "STORAGE-8000-J4.description"
290msgstr "A Service Processor has detected that its peer is no longer available.\n"
291msgid "STORAGE-8000-J4.response"
292msgstr "The service required LED on the enclosure will be illuminated.\n"
293msgid "STORAGE-8000-J4.impact"
294msgstr "A Root Controller Card failed and redundancy has been lost. The SAS fabric is in a degraded state. User data storage is still available.\n"
295msgid "STORAGE-8000-J4.action"
296msgstr "Refer to the Maintenance page in the Sun ZFS Storage UI to identify the failed component. If a repair is required, the repair instructions are located in the Help section of the Sun ZFS Storage UI.\n"
297#
298# code: STORAGE-8000-KQ
299# keys: fault.sp.svc-fail
300#
301msgid "STORAGE-8000-KQ.type"
302msgstr "Fault"
303msgid "STORAGE-8000-KQ.severity"
304msgstr "Major"
305msgid "STORAGE-8000-KQ.description"
306msgstr "A Service Processor service failure has occurred.\n"
307msgid "STORAGE-8000-KQ.response"
308msgstr "The service required LED on the enclosure will be illuminated.\n"
309msgid "STORAGE-8000-KQ.impact"
310msgstr "The SAS fabric may be in a degraded state. User data storage is still available.\n"
311msgid "STORAGE-8000-KQ.action"
312msgstr "Refer to the Maintenance page in the Sun ZFS Storage UI to identify the failed component. If a repair is required, the repair instructions are located in the Help section of the Sun ZFS Storage UI.\n"
313#
314# code: STORAGE-8000-LC
315# keys: fault.temp.fail
316#
317msgid "STORAGE-8000-LC.type"
318msgstr "Fault"
319msgid "STORAGE-8000-LC.severity"
320msgstr "Major"
321msgid "STORAGE-8000-LC.description"
322msgstr "Ambient temperature is outside of normal operating range.\n"
323msgid "STORAGE-8000-LC.response"
324msgstr "The service required LED on the enclosure will be illuminated.\n"
325msgid "STORAGE-8000-LC.impact"
326msgstr "A device in the enclosure may be overheating. Subsequent loss of the device may force the enclosure to shutdown.\n"
327msgid "STORAGE-8000-LC.action"
328msgstr "Check that the ambient temperature is adequately cool, and none of the enclosure air inlets are blocked.\n"
329