xref: /illumos-gate/usr/src/cmd/fm/dicts/SCA500.po (revision dd72704bd9e794056c558153663c739e2012d721)
1#
2# Copyright 2006 Sun Microsystems, Inc.  All rights reserved.
3# Use is subject to license terms.
4#
5# CDDL HEADER START
6#
7# The contents of this file are subject to the terms of the
8# Common Development and Distribution License (the "License").
9# You may not use this file except in compliance with the License.
10#
11# You can obtain a copy of the license at usr/src/OPENSOLARIS.LICENSE
12# or http://www.opensolaris.org/os/licensing.
13# See the License for the specific language governing permissions
14# and limitations under the License.
15#
16# When distributing Covered Code, include this CDDL HEADER in each
17# file and include the License file at usr/src/OPENSOLARIS.LICENSE.
18# If applicable, add the following below this CDDL HEADER, with the
19# fields enclosed by brackets "[]" replaced with your own identifying
20# information: Portions Copyright [yyyy] [name of copyright owner]
21#
22# CDDL HEADER END
23#
24# DO NOT EDIT -- this file is generated by the Event Registry.
25#
26#
27# code: SCA500-8000-0D
28# keys: fault.io.sca500.hw
29#
30msgid "SCA500-8000-0D.type"
31msgstr "Fault"
32msgid "SCA500-8000-0D.severity"
33msgstr "Major"
34msgid "SCA500-8000-0D.description"
35msgstr "The illumos Fault Manager has detected a hardware failure on the Sun Crypto Accelerator 500 card.  Refer to %s for more information."
36msgid "SCA500-8000-0D.response"
37msgstr "The module has been disabled and un-registered as a hardware provider to the illumos Cryptographic Framework."
38msgid "SCA500-8000-0D.impact"
39msgstr "The card will no longer function as a cryptographic accelerator."
40msgid "SCA500-8000-0D.action"
41msgstr "Ensure that the board is securely installed on the system.\n\nUse the cryptoadm(8) command\n\ncryptoadm list -p\n\n\nto check whether 'dca/x' (where x is a number) is listed under 'kernel hardware\nproviders'. If so, run diagnostics on the hardware provider\nfollowing the procedures described in the Sun Crypto Accelerator 500 Board\nUser's Guide.\n\nUse the fmdump(8) command\n\nfmdump -vu event-id\n\n\nto view the results of diagnosis and the specific Field Replaceable\nUnit (FRU) identified for replacement.\n\nThe event-id can be found in the EVENT-ID field of the message.\nFor example:\n\n\nEVENT-ID: 39b30371-f009-c76c-90ee-b245784d2277\n"