xref: /illumos-gate/usr/src/cmd/fm/dicts/PCI.po (revision 20a7641f9918de8574b8b3b47dbe35c4bfc78df1)
1#
2# Copyright 2009 Sun Microsystems, Inc.  All rights reserved.
3# Use is subject to license terms.
4#
5# CDDL HEADER START
6#
7# The contents of this file are subject to the terms of the
8# Common Development and Distribution License (the "License").
9# You may not use this file except in compliance with the License.
10#
11# You can obtain a copy of the license at usr/src/OPENSOLARIS.LICENSE
12# or http://www.opensolaris.org/os/licensing.
13# See the License for the specific language governing permissions
14# and limitations under the License.
15#
16# When distributing Covered Code, include this CDDL HEADER in each
17# file and include the License file at usr/src/OPENSOLARIS.LICENSE.
18# If applicable, add the following below this CDDL HEADER, with the
19# fields enclosed by brackets "[]" replaced with your own identifying
20# information: Portions Copyright [yyyy] [name of copyright owner]
21#
22# CDDL HEADER END
23#
24# DO NOT EDIT -- this file is generated by the Event Registry.
25#
26#
27# code: PCI-8000-0C
28# keys: defect.io.pci.driver
29#
30msgid "PCI-8000-0C.type"
31msgstr "Fault"
32msgid "PCI-8000-0C.severity"
33msgstr "Critical"
34msgid "PCI-8000-0C.description"
35msgstr "A problem was detected in the PCI controller software.  Refer to %s for more information."
36msgid "PCI-8000-0C.response"
37msgstr "One or more of device instances may be disabled."
38msgid "PCI-8000-0C.impact"
39msgstr "Loss of services provided by the device instances associated with this problem."
40msgid "PCI-8000-0C.action"
41msgstr "Ensure latest drivers and patches are installed.  Use fmdump -v -u <EVENT_ID> to identify the module/package, or contact your illumos distribution team for support."
42#
43# code: PCI-8000-1Q
44# keys: fault.io.pci.bus
45#
46msgid "PCI-8000-1Q.type"
47msgstr "Fault"
48msgid "PCI-8000-1Q.severity"
49msgstr "Critical"
50msgid "PCI-8000-1Q.description"
51msgstr "A problem was detected for a PCI bus.  Refer to %s for more information."
52msgid "PCI-8000-1Q.response"
53msgstr "One or more device instances may be disabled."
54msgid "PCI-8000-1Q.impact"
55msgstr "Loss of services provided by the device instances associated with this fault."
56msgid "PCI-8000-1Q.action"
57msgstr "Schedule a repair procedure to replace the affected device.  Use fmdump -v -u <EVENT_ID> to identify the device or contact your illumos distribution team for support."
58#
59# code: PCI-8000-24
60# keys: defect.io.pci.driver fault.io.pci.bus
61#
62msgid "PCI-8000-24.type"
63msgstr "Fault"
64msgid "PCI-8000-24.severity"
65msgstr "Critical"
66msgid "PCI-8000-24.description"
67msgstr "The system has diagnosed a problem, the suspects include one or more \nPCI buses and one or more PCI controller drivers.  Refer to %s for more information."
68msgid "PCI-8000-24.response"
69msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
70msgid "PCI-8000-24.impact"
71msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
72msgid "PCI-8000-24.action"
73msgstr "Use fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s)or driver(s).\n\nCheck for patches to identified device drivers, schedule a repair for \nindicated hardware.\n"
74#
75# code: PCI-8000-3R
76# keys: fault.io.pci.device
77#
78msgid "PCI-8000-3R.type"
79msgstr "Fault"
80msgid "PCI-8000-3R.severity"
81msgstr "Critical"
82msgid "PCI-8000-3R.description"
83msgstr "The system has diagnosed a problem in one or more PCI buses or devices, \nbased on the error telemetry detected by the PCI subsystem.  Refer to %s for more information."
84msgid "PCI-8000-3R.response"
85msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
86msgid "PCI-8000-3R.impact"
87msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
88msgid "PCI-8000-3R.action"
89msgstr "Use fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).\n\nSchedule a repair procedure to replace the affected device."
90#
91# code: PCI-8000-42
92# keys: defect.io.pci.driver fault.io.pci.device
93#
94msgid "PCI-8000-42.type"
95msgstr "Fault"
96msgid "PCI-8000-42.severity"
97msgstr "Critical"
98msgid "PCI-8000-42.description"
99msgstr "The system has diagnosed a problem, the suspects include one or more \nPCI buses and one or more PCI controller drivers.  Refer to %s for more information."
100msgid "PCI-8000-42.response"
101msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
102msgid "PCI-8000-42.impact"
103msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
104msgid "PCI-8000-42.action"
105msgstr "Use fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s)or driver(s).\n\nCheck for patches to identified device drivers, schedule a repair for \nindicated hardware.\n"
106#
107# code: PCI-8000-5X
108# keys: fault.io.pci.bus fault.io.pci.device
109#
110msgid "PCI-8000-5X.type"
111msgstr "Fault"
112msgid "PCI-8000-5X.severity"
113msgstr "Critical"
114msgid "PCI-8000-5X.description"
115msgstr "The system has diagnosed a problem in one or more PCI buses or devices, \nbased on the error telemetry detected by the PCI subsystem.  Refer to %s for more information."
116msgid "PCI-8000-5X.response"
117msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
118msgid "PCI-8000-5X.impact"
119msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
120msgid "PCI-8000-5X.action"
121msgstr "Use fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).\n\nSchedule a repair procedure to replace the affected device."
122#
123# code: PCI-8000-6E
124# keys: defect.io.pci.driver fault.io.pci.bus fault.io.pci.device
125#
126msgid "PCI-8000-6E.type"
127msgstr "Fault"
128msgid "PCI-8000-6E.severity"
129msgstr "Critical"
130msgid "PCI-8000-6E.description"
131msgstr "The system has diagnosed a problem, the suspects include one or more \nPCI buses and one or more PCI controller drivers.  Refer to %s for more information."
132msgid "PCI-8000-6E.response"
133msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
134msgid "PCI-8000-6E.impact"
135msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
136msgid "PCI-8000-6E.action"
137msgstr "Use fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s)or driver(s).\n\nCheck for patches to identified device drivers, schedule a repair for \nindicated hardware.\n"
138#
139# code: PCI-8000-7J
140# keys: fault.io.pci.device-interr
141#
142msgid "PCI-8000-7J.type"
143msgstr "Fault"
144msgid "PCI-8000-7J.severity"
145msgstr "Critical"
146msgid "PCI-8000-7J.description"
147msgstr "An unrecoverable problem was detected for a PCI device.\n  Refer to %s for more information."
148msgid "PCI-8000-7J.response"
149msgstr "One or more device instances may be disabled\n"
150msgid "PCI-8000-7J.impact"
151msgstr "Possible loss of services provided by the device instances associated with this fault\n"
152msgid "PCI-8000-7J.action"
153msgstr "Schedule a repair procedure to replace the affected device.  Use fmadm faulty to identify the device or contact your illumos distribution team for support.\n"
154#
155# code: PCI-8000-8S
156# keys: fault.io.pci.bus-linkerr fault.io.pci.device-interr
157#
158msgid "PCI-8000-8S.type"
159msgstr "Fault"
160msgid "PCI-8000-8S.severity"
161msgstr "Critical"
162msgid "PCI-8000-8S.description"
163msgstr "An unrecoverable problem has been detected on the specified bus or on the specified transmitting device.\n  Refer to %s for more information."
164msgid "PCI-8000-8S.response"
165msgstr "One or more device instances may be disabled\n"
166msgid "PCI-8000-8S.impact"
167msgstr "Possible loss of services provided by the device instances associated with this fault\n"
168msgid "PCI-8000-8S.action"
169msgstr "If a plug-in card is involved check for badly-seated cards or bent pins. Otherwise schedule a repair procedure to replace the affected device.  Use fmadm faulty to identify the device and bus or contact your illumos distribution team for support.\n"
170#
171# code: PCI-8000-95
172# keys: fault.io.pci.device-invreq fault.io.pci.device-noresp
173#
174msgid "PCI-8000-95.type"
175msgstr "Fault"
176msgid "PCI-8000-95.severity"
177msgstr "Major"
178msgid "PCI-8000-95.description"
179msgstr "Either the transmitting device sent an invalid request or the receiving device failed to respond.\n  Refer to %s for more information."
180msgid "PCI-8000-95.response"
181msgstr "One or more device instances may be disabled\n"
182msgid "PCI-8000-95.impact"
183msgstr "Possible loss of services provided by the device instances associated with this fault\n"
184msgid "PCI-8000-95.action"
185msgstr "Ensure that the latest drivers and patches are installed. If a plug-in card is involved check for badly-seated cards or bent pins.  Otherwise schedule a repair procedure to replace the affected device(s).  Use fmadm faulty to identify the devices or contact your illumos distribution team for support.\n"
186#
187# code: PCI-8000-AP
188# keys: fault.io.pci.device-interr fault.io.pci.device-invreq
189#
190msgid "PCI-8000-AP.type"
191msgstr "Fault"
192msgid "PCI-8000-AP.severity"
193msgstr "Major"
194msgid "PCI-8000-AP.description"
195msgstr "Either the transmitting device sent an invalid request or the receiving device is reporting an internal fault.\n  Refer to %s for more information."
196msgid "PCI-8000-AP.response"
197msgstr "One or more device instances may be disabled\n"
198msgid "PCI-8000-AP.impact"
199msgstr "Possible loss of services provided by the device instances associated with this fault\n"
200msgid "PCI-8000-AP.action"
201msgstr "Ensure that the latest drivers and patches are installed.  Otherwise schedule a repair procedure to replace the affected device(s).  Use fmadm faulty to identify the devices or contact your illumos distribution team for support.\n"
202#
203# code: PCI-8000-CA
204# keys: fault.io.pci.device-noresp
205#
206msgid "PCI-8000-CA.type"
207msgstr "Fault"
208msgid "PCI-8000-CA.severity"
209msgstr "Major"
210msgid "PCI-8000-CA.description"
211msgstr "A device is failing to respond\n  Refer to %s for more information."
212msgid "PCI-8000-CA.response"
213msgstr "One or more device instances may be disabled\n"
214msgid "PCI-8000-CA.impact"
215msgstr "Possible loss of services provided by the device instances associated with this fault\n"
216msgid "PCI-8000-CA.action"
217msgstr "Schedule a repair procedure to replace the affected device.  Use fmadm faulty to identify the device or contact your illumos distribution team for support.\n"
218#
219# code: PCI-8000-DH
220# keys: fault.io.pci.bus-linkerr-unaf fault.io.pci.device-interr-unaf
221#
222msgid "PCI-8000-DH.type"
223msgstr "Fault"
224msgid "PCI-8000-DH.severity"
225msgstr "Major"
226msgid "PCI-8000-DH.description"
227msgstr "Too many recovered bus faults have been detected, which indicates a problem with the specified bus or with the specified transmitting device. This may degrade into an unrecoverable fault.\n  Refer to %s for more information."
228msgid "PCI-8000-DH.response"
229msgstr "One or more device instances may be disabled\n"
230msgid "PCI-8000-DH.impact"
231msgstr "Possible loss of services provided by the device instances associated with this fault\n"
232msgid "PCI-8000-DH.action"
233msgstr "If a plug-in card is involved check for badly-seated cards or bent pins. Otherwise schedule a repair procedure to replace the affected device.  Use fmadm faulty to identify the device and bus or contact your illumos distribution team for support.\n"
234#
235# code: PCI-8000-ED
236# keys: fault.io.pci.device-interr-corr
237#
238msgid "PCI-8000-ED.type"
239msgstr "Fault"
240msgid "PCI-8000-ED.severity"
241msgstr "Major"
242msgid "PCI-8000-ED.description"
243msgstr "Too many recovered internal faults have been detected within the specified PCI device. This may degrade into a non-recoverable fault.\n  Refer to %s for more information."
244msgid "PCI-8000-ED.response"
245msgstr "One or more device instances may be disabled\n"
246msgid "PCI-8000-ED.impact"
247msgstr "Possible loss of services provided by the device instances associated with this fault\n"
248msgid "PCI-8000-ED.action"
249msgstr "Schedule a repair procedure to replace the affected device.  Use fmadm faulty to identify the device or contact your illumos distribution team for support.\n"
250#
251# code: PCI-8000-FY
252# keys: fault.io.pci.bus-linkerr-deg fault.io.pci.device-interr-deg
253#
254msgid "PCI-8000-FY.type"
255msgstr "Fault"
256msgid "PCI-8000-FY.severity"
257msgstr "Major"
258msgid "PCI-8000-FY.description"
259msgstr "An unrecoverable problem has been detected on the specified bus or on the specified transmitting device, which has resulted in that device running in a degraded state.\n  Refer to %s for more information."
260msgid "PCI-8000-FY.response"
261msgstr "None\n"
262msgid "PCI-8000-FY.impact"
263msgstr "Degraded services provided by the device instances associated with this fault\n"
264msgid "PCI-8000-FY.action"
265msgstr "If a plug-in card is involved check for badly-seated cards or bent pins. Otherwise schedule a repair procedure to replace the affected device.  Use fmadm faulty to identify the device and bus or contact your illumos distribution team for support.\n"
266#
267# code: PCI-8000-G3
268# keys: fault.io.pci.device-interr-deg
269#
270msgid "PCI-8000-G3.type"
271msgstr "Fault"
272msgid "PCI-8000-G3.severity"
273msgstr "Major"
274msgid "PCI-8000-G3.description"
275msgstr "An unrecoverable problem was detected for a PCI device, which has resulted in that device running in a degraded state.\n  Refer to %s for more information."
276msgid "PCI-8000-G3.response"
277msgstr "None\n"
278msgid "PCI-8000-G3.impact"
279msgstr "Degraded services provided by the device instances associated with this fault\n"
280msgid "PCI-8000-G3.action"
281msgstr "Schedule a repair procedure to replace the affected device.  Use fmadm faulty to identify the device or contact your illumos distribution team for support.\n"
282#
283# code: PCI-8000-HR
284# keys: fault.io.pci.fw_corrupt
285#
286msgid "PCI-8000-HR.type"
287msgstr "Fault"
288msgid "PCI-8000-HR.severity"
289msgstr "Major"
290msgid "PCI-8000-HR.description"
291msgstr "A firmware corruption was detected for a PCI device.\n  Refer to %s for more information."
292msgid "PCI-8000-HR.response"
293msgstr "One or more device instances may be disabled.\n"
294msgid "PCI-8000-HR.impact"
295msgstr "Degraded services provided by the device instances associated with this fault.\n"
296msgid "PCI-8000-HR.action"
297msgstr "Use fmadm faulty to identify the device and then update the firmware to the latest version or schedule a repair procedure to replace the affected device. Contact your illumos distribution team for further information.\n"
298#
299# code: PCI-8000-J4
300# keys: fault.io.pci.fw_mismatch
301#
302msgid "PCI-8000-J4.type"
303msgstr "Fault"
304msgid "PCI-8000-J4.severity"
305msgstr "Major"
306msgid "PCI-8000-J4.description"
307msgstr "A firmware version mismatch was detected for a PCI device.\n  Refer to %s for more information."
308msgid "PCI-8000-J4.response"
309msgstr "One or more device instances may be disabled.\n"
310msgid "PCI-8000-J4.impact"
311msgstr "Degraded services provided by the device instances associated with this fault.\n"
312msgid "PCI-8000-J4.action"
313msgstr "Use fmadm faulty to identify the device and then update the firmware to the latest version. Contact your illumos distribution team for further information.\n"