xref: /illumos-gate/usr/src/cmd/fm/dicts/NXGE.po (revision 942c5e3c2dd127463517e5cc1694ee94ca45e021)
1#
2# Copyright 2007 Sun Microsystems, Inc.  All rights reserved.
3# Use is subject to license terms.
4#
5# CDDL HEADER START
6#
7# The contents of this file are subject to the terms of the
8# Common Development and Distribution License (the "License").
9# You may not use this file except in compliance with the License.
10#
11# You can obtain a copy of the license at usr/src/OPENSOLARIS.LICENSE
12# or http://www.opensolaris.org/os/licensing.
13# See the License for the specific language governing permissions
14# and limitations under the License.
15#
16# When distributing Covered Code, include this CDDL HEADER in each
17# file and include the License file at usr/src/OPENSOLARIS.LICENSE.
18# If applicable, add the following below this CDDL HEADER, with the
19# fields enclosed by brackets "[]" replaced with your own identifying
20# information: Portions Copyright [yyyy] [name of copyright owner]
21#
22# CDDL HEADER END
23#
24#ident	"%Z%%M%	%I%	%E% SMI"
25#
26# DO NOT EDIT -- this file is generated by the Event Registry.
27#
28#
29# code: NXGE-8000-0U
30# keys: fault.io.n2.niu-xfp
31#
32msgid "NXGE-8000-0U.type"
33msgstr "Fault"
34msgid "NXGE-8000-0U.severity"
35msgstr "Critical"
36msgid "NXGE-8000-0U.description"
37msgstr "The XFP optical transceiver is broken or missing.\n  Refer to %s for more information."
38msgid "NXGE-8000-0U.response"
39msgstr "The device instance will be disabled.\n"
40msgid "NXGE-8000-0U.impact"
41msgstr "Loss of services provided by the device instances\nassociated with this fault.\n"
42msgid "NXGE-8000-0U.action"
43msgstr "Check and make sure that the XFP optical transceiver\nis properly installed. If problem persists, schedule a repair\nprocedure to replace the affected device, which can be determined\nusing fmdump -v -u <EVENT_ID>\n"
44#
45# code: NXGE-8000-17
46# keys: fault.io.n2.niu-xaui
47#
48msgid "NXGE-8000-17.type"
49msgstr "Fault"
50msgid "NXGE-8000-17.severity"
51msgstr "Critical"
52msgid "NXGE-8000-17.description"
53msgstr "A fault in the XAUI component used for 10GbE networking. \n  Refer to %s for more information."
54msgid "NXGE-8000-17.response"
55msgstr "The device instance will be disabled.\n"
56msgid "NXGE-8000-17.impact"
57msgstr "Loss of services provided by the device instances\nassociated with this fault.\n"
58msgid "NXGE-8000-17.action"
59msgstr "Schedule a repair procedure for the affected device, which\ncan be determined using fmdump -v -u <EVENT_ID>\n"