1# 2# Copyright 2008 Sun Microsystems, Inc. All rights reserved. 3# Use is subject to license terms. 4# 5# CDDL HEADER START 6# 7# The contents of this file are subject to the terms of the 8# Common Development and Distribution License (the "License"). 9# You may not use this file except in compliance with the License. 10# 11# You can obtain a copy of the license at usr/src/OPENSOLARIS.LICENSE 12# or http://www.opensolaris.org/os/licensing. 13# See the License for the specific language governing permissions 14# and limitations under the License. 15# 16# When distributing Covered Code, include this CDDL HEADER in each 17# file and include the License file at usr/src/OPENSOLARIS.LICENSE. 18# If applicable, add the following below this CDDL HEADER, with the 19# fields enclosed by brackets "[]" replaced with your own identifying 20# information: Portions Copyright [yyyy] [name of copyright owner] 21# 22# CDDL HEADER END 23# 24# DO NOT EDIT -- this file is generated by the Event Registry. 25# 26# 27# code: INTEL-8000-1J 28# keys: fault.cpu.intel.internal 29# 30msgid "INTEL-8000-1J.type" 31msgstr "Fault" 32msgid "INTEL-8000-1J.severity" 33msgstr "Major" 34msgid "INTEL-8000-1J.description" 35msgstr "An internal error has been encountered on this cpu. Refer to %s for more information." 36msgid "INTEL-8000-1J.response" 37msgstr "The system will attempt to offline this cpu to remove it from service." 38msgid "INTEL-8000-1J.impact" 39msgstr "Performance of this system may be affected." 40msgid "INTEL-8000-1J.action" 41msgstr "Schedule a repair procedure to replace the affected CPU. Use 'fmadm faulty' to identify the module." 42# 43# code: INTEL-8000-22 44# keys: fault.cpu.intel.l0cache 45# 46msgid "INTEL-8000-22.type" 47msgstr "Fault" 48msgid "INTEL-8000-22.severity" 49msgstr "Major" 50msgid "INTEL-8000-22.description" 51msgstr "A level 0 cache on this cpu is faulty. Refer to %s for more information." 52msgid "INTEL-8000-22.response" 53msgstr "The system will attempt to offline this cpu to remove it from service." 54msgid "INTEL-8000-22.impact" 55msgstr "Performance of this system may be affected." 56msgid "INTEL-8000-22.action" 57msgstr "Schedule a repair procedure to replace the affected CPU. Use 'fmadm faulty' to identify the module." 58# 59# code: INTEL-8000-3X 60# keys: fault.cpu.intel.l1cache 61# 62msgid "INTEL-8000-3X.type" 63msgstr "Fault" 64msgid "INTEL-8000-3X.severity" 65msgstr "Major" 66msgid "INTEL-8000-3X.description" 67msgstr "A level 1 cache on this cpu is faulty. Refer to %s for more information." 68msgid "INTEL-8000-3X.response" 69msgstr "The system will attempt to offline this cpu to remove it from service." 70msgid "INTEL-8000-3X.impact" 71msgstr "Performance of this system may be affected." 72msgid "INTEL-8000-3X.action" 73msgstr "Schedule a repair procedure to replace the affected CPU. Use 'fmadm faulty' to identify the module." 74# 75# code: INTEL-8000-44 76# keys: fault.cpu.intel.l2cache 77# 78msgid "INTEL-8000-44.type" 79msgstr "Fault" 80msgid "INTEL-8000-44.severity" 81msgstr "Major" 82msgid "INTEL-8000-44.description" 83msgstr "A level 2 cache on this cpu is faulty. Refer to %s for more information." 84msgid "INTEL-8000-44.response" 85msgstr "The system will attempt to offline this cpu to remove it from service." 86msgid "INTEL-8000-44.impact" 87msgstr "Performance of this system may be affected." 88msgid "INTEL-8000-44.action" 89msgstr "Schedule a repair procedure to replace the affected CPU. Use 'fmadm faulty' to identify the module." 90# 91# code: INTEL-8000-5R 92# keys: fault.cpu.intel.cache 93# 94msgid "INTEL-8000-5R.type" 95msgstr "Fault" 96msgid "INTEL-8000-5R.severity" 97msgstr "Major" 98msgid "INTEL-8000-5R.description" 99msgstr "A cache on this cpu is faulty. Refer to %s for more information." 100msgid "INTEL-8000-5R.response" 101msgstr "The system will attempt to offline this cpu to remove it from service." 102msgid "INTEL-8000-5R.impact" 103msgstr "Performance of this system may be affected." 104msgid "INTEL-8000-5R.action" 105msgstr "Schedule a repair procedure to replace the affected CPU. Use 'fmadm faulty' to identify the module." 106# 107# code: INTEL-8000-6C 108# keys: fault.cpu.intel.l0dtlb 109# 110msgid "INTEL-8000-6C.type" 111msgstr "Fault" 112msgid "INTEL-8000-6C.severity" 113msgstr "Major" 114msgid "INTEL-8000-6C.description" 115msgstr "A level 0 Data TLB on this cpu is faulty. Refer to %s for more information." 116msgid "INTEL-8000-6C.response" 117msgstr "The system will attempt to offline this cpu to remove it from service." 118msgid "INTEL-8000-6C.impact" 119msgstr "Performance of this system may be affected." 120msgid "INTEL-8000-6C.action" 121msgstr "Schedule a repair procedure to replace the affected CPU. Use 'fmadm faulty' to identify the module." 122# 123# code: INTEL-8000-7Q 124# keys: fault.cpu.intel.l1dtlb 125# 126msgid "INTEL-8000-7Q.type" 127msgstr "Fault" 128msgid "INTEL-8000-7Q.severity" 129msgstr "Major" 130msgid "INTEL-8000-7Q.description" 131msgstr "A level 1 Data TLB on this cpu is faulty. Refer to %s for more information." 132msgid "INTEL-8000-7Q.response" 133msgstr "The system will attempt to offline this cpu to remove it from service." 134msgid "INTEL-8000-7Q.impact" 135msgstr "Performance of this system may be affected." 136msgid "INTEL-8000-7Q.action" 137msgstr "Schedule a repair procedure to replace the affected CPU. Use 'fmadm faulty' to identify the module." 138# 139# code: INTEL-8000-8Y 140# keys: fault.cpu.intel.l2dtlb 141# 142msgid "INTEL-8000-8Y.type" 143msgstr "Fault" 144msgid "INTEL-8000-8Y.severity" 145msgstr "Major" 146msgid "INTEL-8000-8Y.description" 147msgstr "A level 2 Data TLB on this cpu is faulty. Refer to %s for more information." 148msgid "INTEL-8000-8Y.response" 149msgstr "The system will attempt to offline this cpu to remove it from service." 150msgid "INTEL-8000-8Y.impact" 151msgstr "Performance of this system may be affected." 152msgid "INTEL-8000-8Y.action" 153msgstr "Schedule a repair procedure to replace the affected CPU. Use 'fmadm faulty' to identify the module." 154# 155# code: INTEL-8000-93 156# keys: fault.cpu.intel.dtlb 157# 158msgid "INTEL-8000-93.type" 159msgstr "Fault" 160msgid "INTEL-8000-93.severity" 161msgstr "Major" 162msgid "INTEL-8000-93.description" 163msgstr "A Data TLB on this cpu is faulty. Refer to %s for more information." 164msgid "INTEL-8000-93.response" 165msgstr "The system will attempt to offline this cpu to remove it from service." 166msgid "INTEL-8000-93.impact" 167msgstr "Performance of this system may be affected." 168msgid "INTEL-8000-93.action" 169msgstr "Schedule a repair procedure to replace the affected CPU. Use 'fmadm faulty' to identify the module." 170# 171# code: INTEL-8000-AH 172# keys: fault.cpu.intel.l0itlb 173# 174msgid "INTEL-8000-AH.type" 175msgstr "Fault" 176msgid "INTEL-8000-AH.severity" 177msgstr "Major" 178msgid "INTEL-8000-AH.description" 179msgstr "A level 0 Instruction TLB on this cpu is faulty. Refer to %s for more information." 180msgid "INTEL-8000-AH.response" 181msgstr "The system will attempt to offline this cpu to remove it from service." 182msgid "INTEL-8000-AH.impact" 183msgstr "Performance of this system may be affected." 184msgid "INTEL-8000-AH.action" 185msgstr "Schedule a repair procedure to replace the affected CPU. Use 'fmadm faulty' to identify the module." 186# 187# code: INTEL-8000-CD 188# keys: fault.cpu.intel.l1itlb 189# 190msgid "INTEL-8000-CD.type" 191msgstr "Fault" 192msgid "INTEL-8000-CD.severity" 193msgstr "Major" 194msgid "INTEL-8000-CD.description" 195msgstr "A level 1 Instruction TLB on this cpu is faulty. Refer to %s for more information." 196msgid "INTEL-8000-CD.response" 197msgstr "The system will attempt to offline this cpu to remove it from service." 198msgid "INTEL-8000-CD.impact" 199msgstr "Performance of this system may be affected." 200msgid "INTEL-8000-CD.action" 201msgstr "Schedule a repair procedure to replace the affected CPU. Use 'fmadm faulty' to identify the module." 202# 203# code: INTEL-8000-DP 204# keys: fault.cpu.intel.l2itlb 205# 206msgid "INTEL-8000-DP.type" 207msgstr "Fault" 208msgid "INTEL-8000-DP.severity" 209msgstr "Major" 210msgid "INTEL-8000-DP.description" 211msgstr "A level 2 Instruction TLB on this cpu is faulty. Refer to %s for more information." 212msgid "INTEL-8000-DP.response" 213msgstr "The system will attempt to offline this cpu to remove it from service." 214msgid "INTEL-8000-DP.impact" 215msgstr "Performance of this system may be affected." 216msgid "INTEL-8000-DP.action" 217msgstr "Schedule a repair procedure to replace the affected CPU. Use 'fmadm faulty' to identify the module." 218# 219# code: INTEL-8000-EA 220# keys: fault.cpu.intel.itlb 221# 222msgid "INTEL-8000-EA.type" 223msgstr "Fault" 224msgid "INTEL-8000-EA.severity" 225msgstr "Major" 226msgid "INTEL-8000-EA.description" 227msgstr "An Instruction TLB on this cpu is faulty. Refer to %s for more information." 228msgid "INTEL-8000-EA.response" 229msgstr "The system will attempt to offline this cpu to remove it from service." 230msgid "INTEL-8000-EA.impact" 231msgstr "Performance of this system may be affected." 232msgid "INTEL-8000-EA.action" 233msgstr "Schedule a repair procedure to replace the affected CPU. Use 'fmadm faulty' to identify the module." 234# 235# code: INTEL-8000-FS 236# keys: fault.cpu.intel.l0tlb 237# 238msgid "INTEL-8000-FS.type" 239msgstr "Fault" 240msgid "INTEL-8000-FS.severity" 241msgstr "Major" 242msgid "INTEL-8000-FS.description" 243msgstr "A level 0 TLB on this cpu is faulty. Refer to %s for more information." 244msgid "INTEL-8000-FS.response" 245msgstr "The system will attempt to offline this cpu to remove it from service." 246msgid "INTEL-8000-FS.impact" 247msgstr "Performance of this system may be affected." 248msgid "INTEL-8000-FS.action" 249msgstr "Schedule a repair procedure to replace the affected CPU. Use 'fmadm faulty' to identify the module." 250# 251# code: INTEL-8000-G5 252# keys: fault.cpu.intel.l1tlb 253# 254msgid "INTEL-8000-G5.type" 255msgstr "Fault" 256msgid "INTEL-8000-G5.severity" 257msgstr "Major" 258msgid "INTEL-8000-G5.description" 259msgstr "A level 1 TLB on this cpu is faulty. Refer to %s for more information." 260msgid "INTEL-8000-G5.response" 261msgstr "The system will attempt to offline this cpu to remove it from service." 262msgid "INTEL-8000-G5.impact" 263msgstr "Performance of this system may be affected." 264msgid "INTEL-8000-G5.action" 265msgstr "Schedule a repair procedure to replace the affected CPU. Use 'fmadm faulty' to identify the module." 266# 267# code: INTEL-8000-HX 268# keys: fault.cpu.intel.l2tlb 269# 270msgid "INTEL-8000-HX.type" 271msgstr "Fault" 272msgid "INTEL-8000-HX.severity" 273msgstr "Major" 274msgid "INTEL-8000-HX.description" 275msgstr "A level 2 TLB on this cpu is faulty. Refer to %s for more information." 276msgid "INTEL-8000-HX.response" 277msgstr "The system will attempt to offline this cpu to remove it from service." 278msgid "INTEL-8000-HX.impact" 279msgstr "Performance of this system may be affected." 280msgid "INTEL-8000-HX.action" 281msgstr "Schedule a repair procedure to replace the affected CPU. Use 'fmadm faulty' to identify the module." 282# 283# code: INTEL-8000-J2 284# keys: fault.cpu.intel.tlb 285# 286msgid "INTEL-8000-J2.type" 287msgstr "Fault" 288msgid "INTEL-8000-J2.severity" 289msgstr "Major" 290msgid "INTEL-8000-J2.description" 291msgstr "A TLB on this cpu is faulty. Refer to %s for more information." 292msgid "INTEL-8000-J2.response" 293msgstr "The system will attempt to offline this cpu to remove it from service." 294msgid "INTEL-8000-J2.impact" 295msgstr "Performance of this system may be affected." 296msgid "INTEL-8000-J2.action" 297msgstr "Schedule a repair procedure to replace the affected CPU. Use 'fmadm faulty' to identify the module." 298# 299# code: INTEL-8000-KJ 300# keys: fault.cpu.intel.l0dcache 301# 302msgid "INTEL-8000-KJ.type" 303msgstr "Fault" 304msgid "INTEL-8000-KJ.severity" 305msgstr "Major" 306msgid "INTEL-8000-KJ.description" 307msgstr "A level 0 Data Cache on this cpu is faulty. Refer to %s for more information." 308msgid "INTEL-8000-KJ.response" 309msgstr "The system will attempt to offline this cpu to remove it from service." 310msgid "INTEL-8000-KJ.impact" 311msgstr "Performance of this system may be affected." 312msgid "INTEL-8000-KJ.action" 313msgstr "Schedule a repair procedure to replace the affected CPU. Use 'fmadm faulty' to identify the module." 314# 315# code: INTEL-8000-LE 316# keys: fault.cpu.intel.l1dcache 317# 318msgid "INTEL-8000-LE.type" 319msgstr "Fault" 320msgid "INTEL-8000-LE.severity" 321msgstr "Major" 322msgid "INTEL-8000-LE.description" 323msgstr "A level 1 Data Cache on this cpu is faulty. Refer to %s for more information." 324msgid "INTEL-8000-LE.response" 325msgstr "The system will attempt to offline this cpu to remove it from service." 326msgid "INTEL-8000-LE.impact" 327msgstr "Performance of this system may be affected." 328msgid "INTEL-8000-LE.action" 329msgstr "Schedule a repair procedure to replace the affected CPU. Use 'fmadm faulty' to identify the module." 330# 331# code: INTEL-8000-MQ 332# keys: fault.cpu.intel.l2dcache 333# 334msgid "INTEL-8000-MQ.type" 335msgstr "Fault" 336msgid "INTEL-8000-MQ.severity" 337msgstr "Major" 338msgid "INTEL-8000-MQ.description" 339msgstr "A level 2 Data Cache on this cpu is faulty. Refer to %s for more information." 340msgid "INTEL-8000-MQ.response" 341msgstr "The system will attempt to offline this cpu to remove it from service." 342msgid "INTEL-8000-MQ.impact" 343msgstr "Performance of this system may be affected." 344msgid "INTEL-8000-MQ.action" 345msgstr "Schedule a repair procedure to replace the affected CPU. Use 'fmadm faulty' to identify the module." 346# 347# code: INTEL-8000-NC 348# keys: fault.cpu.intel.dcache 349# 350msgid "INTEL-8000-NC.type" 351msgstr "Fault" 352msgid "INTEL-8000-NC.severity" 353msgstr "Major" 354msgid "INTEL-8000-NC.description" 355msgstr "A Data Cache on this cpu is faulty. Refer to %s for more information." 356msgid "INTEL-8000-NC.response" 357msgstr "The system will attempt to offline this cpu to remove it from service." 358msgid "INTEL-8000-NC.impact" 359msgstr "Performance of this system may be affected." 360msgid "INTEL-8000-NC.action" 361msgstr "Schedule a repair procedure to replace the affected CPU. Use 'fmadm faulty' to identify the module." 362# 363# code: INTEL-8000-PR 364# keys: fault.cpu.intel.l0icache 365# 366msgid "INTEL-8000-PR.type" 367msgstr "Fault" 368msgid "INTEL-8000-PR.severity" 369msgstr "Major" 370msgid "INTEL-8000-PR.description" 371msgstr "A level 0 Instruction Cache on this cpu is faulty. Refer to %s for more information." 372msgid "INTEL-8000-PR.response" 373msgstr "The system will attempt to offline this cpu to remove it from service." 374msgid "INTEL-8000-PR.impact" 375msgstr "Performance of this system may be affected." 376msgid "INTEL-8000-PR.action" 377msgstr "Schedule a repair procedure to replace the affected CPU. Use 'fmadm faulty' to identify the module." 378# 379# code: INTEL-8000-Q4 380# keys: fault.cpu.intel.l1icache 381# 382msgid "INTEL-8000-Q4.type" 383msgstr "Fault" 384msgid "INTEL-8000-Q4.severity" 385msgstr "Major" 386msgid "INTEL-8000-Q4.description" 387msgstr "A level 1 Instruction Cache on this cpu is faulty. Refer to %s for more information." 388msgid "INTEL-8000-Q4.response" 389msgstr "The system will attempt to offline this cpu to remove it from service." 390msgid "INTEL-8000-Q4.impact" 391msgstr "Performance of this system may be affected." 392msgid "INTEL-8000-Q4.action" 393msgstr "Schedule a repair procedure to replace the affected CPU. Use 'fmadm faulty' to identify the module." 394# 395# code: INTEL-8000-RD 396# keys: fault.cpu.intel.l2icache 397# 398msgid "INTEL-8000-RD.type" 399msgstr "Fault" 400msgid "INTEL-8000-RD.severity" 401msgstr "Major" 402msgid "INTEL-8000-RD.description" 403msgstr "A level 2 Instruction Cache on this cpu is faulty. Refer to %s for more information." 404msgid "INTEL-8000-RD.response" 405msgstr "The system will attempt to offline this cpu to remove it from service." 406msgid "INTEL-8000-RD.impact" 407msgstr "Performance of this system may be affected." 408msgid "INTEL-8000-RD.action" 409msgstr "Schedule a repair procedure to replace the affected CPU. Use 'fmadm faulty' to identify the module." 410# 411# code: INTEL-8000-SH 412# keys: fault.cpu.intel.icache 413# 414msgid "INTEL-8000-SH.type" 415msgstr "Fault" 416msgid "INTEL-8000-SH.severity" 417msgstr "Major" 418msgid "INTEL-8000-SH.description" 419msgstr "An Instruction Cache on this cpu is faulty. Refer to %s for more information." 420msgid "INTEL-8000-SH.response" 421msgstr "The system will attempt to offline this cpu to remove it from service." 422msgid "INTEL-8000-SH.impact" 423msgstr "Performance of this system may be affected." 424msgid "INTEL-8000-SH.action" 425msgstr "Schedule a repair procedure to replace the affected CPU. Use 'fmadm faulty' to identify the module." 426# 427# code: INTEL-8000-T3 428# keys: fault.cpu.intel.bus_interconnect 429# 430msgid "INTEL-8000-T3.type" 431msgstr "Fault" 432msgid "INTEL-8000-T3.severity" 433msgstr "Major" 434msgid "INTEL-8000-T3.description" 435msgstr "Excessive errors from a bus, memory or IO. Refer to %s for more information." 436msgid "INTEL-8000-T3.response" 437msgstr "No automated response action is possible" 438msgid "INTEL-8000-T3.impact" 439msgstr "System may panic or be reset by BIOS" 440msgid "INTEL-8000-T3.action" 441msgstr "Schedule a repair procedure to check seating of memory dimms. Schedule a repair procedure to check seating of io cards" 442# 443# code: INTEL-8000-UY 444# keys: fault.cpu.intel.bus_interconnect_memory 445# 446msgid "INTEL-8000-UY.type" 447msgstr "Fault" 448msgid "INTEL-8000-UY.severity" 449msgstr "Major" 450msgid "INTEL-8000-UY.description" 451msgstr "Excessive errors from memory accesses. Refer to %s for more information." 452msgid "INTEL-8000-UY.response" 453msgstr "No automated response action is possible" 454msgid "INTEL-8000-UY.impact" 455msgstr "System may panic or be reset by BIOS" 456msgid "INTEL-8000-UY.action" 457msgstr "Schedule a repair procedure to reseat or replace memory dimms" 458# 459# code: INTEL-8000-V5 460# keys: fault.cpu.intel.bus_interconnect_io 461# 462msgid "INTEL-8000-V5.type" 463msgstr "Fault" 464msgid "INTEL-8000-V5.severity" 465msgstr "Major" 466msgid "INTEL-8000-V5.description" 467msgstr "Excessive errors from IO accesses. Refer to %s for more information." 468msgid "INTEL-8000-V5.response" 469msgstr "No automated response action is possible" 470msgid "INTEL-8000-V5.impact" 471msgstr "System may panic or be reset by BIOS" 472msgid "INTEL-8000-V5.action" 473msgstr "Schedule a repair procedure to check seating of io cards" 474# 475# code: INTEL-8000-WS 476# keys: fault.cpu.intel.nb.fsb 477# 478msgid "INTEL-8000-WS.type" 479msgstr "Fault" 480msgid "INTEL-8000-WS.severity" 481msgstr "Critical" 482msgid "INTEL-8000-WS.description" 483msgstr "Front Side bus between CPU and northbridge Refer to %s for more information." 484msgid "INTEL-8000-WS.response" 485msgstr "System panic or reset by BIOS" 486msgid "INTEL-8000-WS.impact" 487msgstr "System may panic or be reset by BIOS" 488msgid "INTEL-8000-WS.action" 489msgstr "Schedule a repair procedure to replace the affected CPU. Use 'fmadm faulty' to identify the module." 490# 491# code: INTEL-8000-XA 492# keys: fault.memory.intel.fbd.berr 493# 494msgid "INTEL-8000-XA.type" 495msgstr "Fault" 496msgid "INTEL-8000-XA.severity" 497msgstr "Major" 498msgid "INTEL-8000-XA.description" 499msgstr "A fault occurred on a memory dimm channel Refer to %s for more information." 500msgid "INTEL-8000-XA.response" 501msgstr "System panic or reset by BIOS" 502msgid "INTEL-8000-XA.impact" 503msgstr "System may not boot" 504msgid "INTEL-8000-XA.action" 505msgstr "reseat or replace dimms on channel. Use 'fmadm faulty' to identify the channel." 506# 507# code: INTEL-8000-YP 508# keys: fault.memory.intel.fbd.alert 509# 510msgid "INTEL-8000-YP.type" 511msgstr "Fault" 512msgid "INTEL-8000-YP.severity" 513msgstr "Critical" 514msgid "INTEL-8000-YP.description" 515msgstr "Memory Controller detected a corrupted acknowledgment on a retry of a non-redundant memory write or configuration write Refer to %s for more information." 516msgid "INTEL-8000-YP.response" 517msgstr "System panic or reset by BIOS" 518msgid "INTEL-8000-YP.impact" 519msgstr "System may be unexpectedly reset" 520msgid "INTEL-8000-YP.action" 521msgstr "reseat or replace dimm. Use 'fmadm faulty' to identify the dimm." 522# 523# code: INTEL-8001-0A 524# keys: fault.memory.intel.fbd.crc 525# 526msgid "INTEL-8001-0A.type" 527msgstr "Fault" 528msgid "INTEL-8001-0A.severity" 529msgstr "Critical" 530msgid "INTEL-8001-0A.description" 531msgstr "Memory Controller detected a corrupted CRC error on a non-redundant retry of memory or dimm configuration read. Refer to %s for more information." 532msgid "INTEL-8001-0A.response" 533msgstr "System panic or reset by BIOS" 534msgid "INTEL-8001-0A.impact" 535msgstr "System may not boot" 536msgid "INTEL-8001-0A.action" 537msgstr "reseat or replace dimm. Use 'fmadm faulty' to identify the dimm." 538# 539# code: INTEL-8001-1P 540# keys: fault.memory.intel.fbd.ch 541# 542msgid "INTEL-8001-1P.type" 543msgstr "Fault" 544msgid "INTEL-8001-1P.severity" 545msgstr "Major" 546msgid "INTEL-8001-1P.description" 547msgstr "Memory Controller detected a corrupted CRC error on a non-redundant retry of memory or dimm configuration read Refer to %s for more information." 548msgid "INTEL-8001-1P.response" 549msgstr "Hardware redundancy or correction of memory errors may be lost" 550msgid "INTEL-8001-1P.impact" 551msgstr "There may be a loss of hardware redundancy or performance" 552msgid "INTEL-8001-1P.action" 553msgstr "reseat or replace dimm. Use 'fmadm faulty' to identify the dimm." 554# 555# code: INTEL-8001-25 556# keys: fault.memory.intel.fbd.reset_timeout 557# 558msgid "INTEL-8001-25.type" 559msgstr "Fault" 560msgid "INTEL-8001-25.severity" 561msgstr "Critical" 562msgid "INTEL-8001-25.description" 563msgstr "Memory Controller detected fast reset timeout while trying to recover from read or write Refer to %s for more information." 564msgid "INTEL-8001-25.response" 565msgstr "System panic or reset by BIOS" 566msgid "INTEL-8001-25.impact" 567msgstr "System may not boot" 568msgid "INTEL-8001-25.action" 569msgstr "reseat or replace dimm. Use 'fmadm faulty' to identify the dimms." 570# 571# code: INTEL-8001-3S 572# keys: fault.memory.intel.fbd.otf 573# 574msgid "INTEL-8001-3S.type" 575msgstr "Fault" 576msgid "INTEL-8001-3S.severity" 577msgstr "Major" 578msgid "INTEL-8001-3S.description" 579msgstr "Intelligent throttling is disabled in the memory controller and the thermal sensor detected over temperature Refer to %s for more information." 580msgid "INTEL-8001-3S.response" 581msgstr "System panic or reset by BIOS" 582msgid "INTEL-8001-3S.impact" 583msgstr "System may be unexpectedly reset" 584msgid "INTEL-8001-3S.action" 585msgstr "Enable intelligent throttling in BIOS or supply more cooling" 586# 587# code: INTEL-8001-43 588# keys: fault.cpu.intel.nb.ie 589# 590msgid "INTEL-8001-43.type" 591msgstr "Fault" 592msgid "INTEL-8001-43.severity" 593msgstr "Critical" 594msgid "INTEL-8001-43.description" 595msgstr "Northbridge has detected an internal error Refer to %s for more information." 596msgid "INTEL-8001-43.response" 597msgstr "System panic or reset by BIOS" 598msgid "INTEL-8001-43.impact" 599msgstr "System may be unexpectedly reset" 600msgid "INTEL-8001-43.action" 601msgstr "Replace motherboard" 602# 603# code: INTEL-8001-5Y 604# keys: fault.cpu.intel.nb.dma 605# 606msgid "INTEL-8001-5Y.type" 607msgstr "Fault" 608msgid "INTEL-8001-5Y.severity" 609msgstr "Major" 610msgid "INTEL-8001-5Y.description" 611msgstr "Northbridge dma controller has detected an error Refer to %s for more information." 612msgid "INTEL-8001-5Y.response" 613msgstr "System panic or reset by BIOS" 614msgid "INTEL-8001-5Y.impact" 615msgstr "System may be unexpectedly reset" 616msgid "INTEL-8001-5Y.action" 617msgstr "Replace motherboard" 618# 619# code: INTEL-8001-6D 620# keys: fault.memory.intel.fbd.mem_ds 621# 622msgid "INTEL-8001-6D.type" 623msgstr "Fault" 624msgid "INTEL-8001-6D.severity" 625msgstr "Major" 626msgid "INTEL-8001-6D.description" 627msgstr "The memory controller has deployed the spare dimm rank to replace a rank which has had too many errors Refer to %s for more information." 628msgid "INTEL-8001-6D.response" 629msgstr "There is no spare rank for this memory controller" 630msgid "INTEL-8001-6D.impact" 631msgstr "There is a loss of hardware redundancy" 632msgid "INTEL-8001-6D.action" 633msgstr "Replace faulty dimm. Use 'fmadm faulty' to identify the dimm." 634# 635# code: INTEL-8001-7H 636# keys: fault.memory.intel.page_ce 637# 638msgid "INTEL-8001-7H.type" 639msgstr "Fault" 640msgid "INTEL-8001-7H.severity" 641msgstr "Minor" 642msgid "INTEL-8001-7H.description" 643msgstr "This message indicates that the Solaris Fault Manager has received reports that correctable memory errors attributed to a single page of physical memory have been detected. Ongoing diagnosis applied to the error reports has determined that a page is faulty. No repair action is required or recommended at this time. No data has been lost. If and when the Solaris Fault Manager determines that there is sufficient cause, service action will be recommended at that time. Refer to %s for more information." 644msgid "INTEL-8001-7H.response" 645msgstr "An attempt will be made to remove this memory page from service." 646msgid "INTEL-8001-7H.impact" 647msgstr "The performance of the system may be minimally impacted as a result of removing the memory page from operation." 648msgid "INTEL-8001-7H.action" 649msgstr "No repair action is recommended at this time." 650# 651# code: INTEL-8001-8R 652# keys: fault.memory.intel.page_ue 653# 654msgid "INTEL-8001-8R.type" 655msgstr "Fault" 656msgid "INTEL-8001-8R.severity" 657msgstr "Major" 658msgid "INTEL-8001-8R.description" 659msgstr "A page has been retired for uncorrectable multiple-bit errors. This fault class is an internal implementation peculiarity and can be ignored by system administrators; action is only necessary if it is followed by a related dimm fault diagnosis (as should always be the case for uncorrectable errors). Refer to %s for more information." 660msgid "INTEL-8001-8R.response" 661msgstr "An attempt will be made to remove this memory page from service." 662msgid "INTEL-8001-8R.impact" 663msgstr "The performance of the system may be minimally impacted as a result of removing the memory page from operation." 664msgid "INTEL-8001-8R.action" 665msgstr "No repair action is recommended at this time." 666# 667# code: INTEL-8001-94 668# keys: fault.memory.intel.dimm_ce 669# 670msgid "INTEL-8001-94.type" 671msgstr "Fault" 672msgid "INTEL-8001-94.severity" 673msgstr "Minor" 674msgid "INTEL-8001-94.description" 675msgstr "This message indicates that the Solaris Fault Manager has received reports of single bit correctable errors from a Memory Module at a rate exceeding acceptable levels, and a Memory Module fault has been diagnosed. No data has been lost, and pages of the affected Memory Module are being retired as errors are encountered. The recommended service action for this event is to schedule replacement of the affected Memory Module at the earliest possible convenience. The errors are correctable in nature so they do not present an immediate threat to system availability, however they may be an indication of an impending uncorrectable failure mode. Use 'fmadm faulty' to identify the dimm to replace. Refer to %s for more information." 676msgid "INTEL-8001-94.response" 677msgstr "Pages of memory associated with this memory module are being removed from service as errors are reported." 678msgid "INTEL-8001-94.impact" 679msgstr "Total system memory capacity will be reduced as pages are retired." 680msgid "INTEL-8001-94.action" 681msgstr "Schedule a repair procedure to replace the affected memory module. Use fmadm faulty -u to identify the module." 682# 683# code: INTEL-8001-AQ 684# keys: fault.memory.intel.dimm_ue 685# 686msgid "INTEL-8001-AQ.type" 687msgstr "Fault" 688msgid "INTEL-8001-AQ.severity" 689msgstr "Critical" 690msgid "INTEL-8001-AQ.description" 691msgstr "This message indicates that the Solaris Fault Manager has received reports of Uncorrectable Multiple-Bit memory errors associated with a Memory Module have been detected, and a Memory Module fault has been diagnosed. No data has been lost, and pages of the affected Memory Module are being retired as errors are encountered. The recommended service action for this event is to schedule replacement of the affected Memory Modules at the earliest possible convenience. Refer to %s for more information." 692msgid "INTEL-8001-AQ.response" 693msgstr "Pages of memory associated with this memory module are being removed from service as errors are reported." 694msgid "INTEL-8001-AQ.impact" 695msgstr "Total system memory capacity will be reduced as pages are retired." 696msgid "INTEL-8001-AQ.action" 697msgstr "Schedule a repair procedure to replace the affected memory module. Use fmdump -v -u to identify the module." 698# 699# code: INTEL-8001-CC 700# keys: fault.cpu.intel.nb.otf 701# 702msgid "INTEL-8001-CC.type" 703msgstr "Fault" 704msgid "INTEL-8001-CC.severity" 705msgstr "Major" 706msgid "INTEL-8001-CC.description" 707msgstr "Northbridge detected over temperature Refer to %s for more information." 708msgid "INTEL-8001-CC.response" 709msgstr "System panic or reset by BIOS" 710msgid "INTEL-8001-CC.impact" 711msgstr "System may be unexpectedly reset" 712msgid "INTEL-8001-CC.action" 713msgstr "Supply more cooling" 714# 715# code: INTEL-8001-DJ 716# keys: fault.cpu.intel.quickpath.mem_parity 717# 718msgid "INTEL-8001-DJ.type" 719msgstr "Fault" 720msgid "INTEL-8001-DJ.severity" 721msgstr "Major" 722msgid "INTEL-8001-DJ.description" 723msgstr "Bad parity detected in memory write buffer or byte mask. Refer to %s for more information." 724msgid "INTEL-8001-DJ.response" 725msgstr "System panic or reset by BIOS" 726msgid "INTEL-8001-DJ.impact" 727msgstr "System may panic or be reset by BIOS" 728msgid "INTEL-8001-DJ.action" 729msgstr "Schedule a repair procedure to replace processor. Use 'fmadm faulty' to identify FRU." 730# 731# code: INTEL-8001-EE 732# keys: fault.cpu.intel.quickpath.mem_addr_parity 733# 734msgid "INTEL-8001-EE.type" 735msgstr "Fault" 736msgid "INTEL-8001-EE.severity" 737msgstr "Major" 738msgid "INTEL-8001-EE.description" 739msgstr "Bad parity detected in memory address within controller. Refer to %s for more information." 740msgid "INTEL-8001-EE.response" 741msgstr "System panic or reset by BIOS" 742msgid "INTEL-8001-EE.impact" 743msgstr "System may panic or be reset by BIOS" 744msgid "INTEL-8001-EE.action" 745msgstr "Schedule a repair procedure to replace processor. Use 'fmadm faulty' to identify FRU." 746# 747# code: INTEL-8001-FX 748# keys: fault.cpu.intel.quickpath.mem_bad_addr 749# 750msgid "INTEL-8001-FX.type" 751msgstr "Fault" 752msgid "INTEL-8001-FX.severity" 753msgstr "Major" 754msgid "INTEL-8001-FX.description" 755msgstr "Memory address is outside range mapped to memory dimms. Refer to %s for more information." 756msgid "INTEL-8001-FX.response" 757msgstr "System panic or reset by BIOS" 758msgid "INTEL-8001-FX.impact" 759msgstr "System may panic or be reset by BIOS" 760msgid "INTEL-8001-FX.action" 761msgstr "Schedule a repair procedure to replace processor. Use 'fmadm faulty' to identify FRU." 762# 763# code: INTEL-8001-G2 764# keys: fault.cpu.intel.quickpath.mem_spare 765# 766msgid "INTEL-8001-G2.type" 767msgstr "Fault" 768msgid "INTEL-8001-G2.severity" 769msgstr "Major" 770msgid "INTEL-8001-G2.description" 771msgstr "A fatal error occured while trying to deploy spare memory. Refer to %s for more information." 772msgid "INTEL-8001-G2.response" 773msgstr "System panic or reset by BIOS" 774msgid "INTEL-8001-G2.impact" 775msgstr "System may panic or be reset by BIOS" 776msgid "INTEL-8001-G2.action" 777msgstr "Replace faulty dimm. Use 'fmadm faulty' to identify the dimm." 778# 779# code: INTEL-8001-HS 780# keys: fault.cpu.intel.quickpath.mem_bad_id 781# 782msgid "INTEL-8001-HS.type" 783msgstr "Fault" 784msgid "INTEL-8001-HS.severity" 785msgstr "Major" 786msgid "INTEL-8001-HS.description" 787msgstr "Memory controller received bad transaction tracker ID from interconnect. Refer to %s for more information." 788msgid "INTEL-8001-HS.response" 789msgstr "System panic or reset by BIOS" 790msgid "INTEL-8001-HS.impact" 791msgstr "System may panic or be reset by BIOS" 792msgid "INTEL-8001-HS.action" 793msgstr "Schedule a repair procedure to replace processor. Use 'fmadm faulty' to identify FRU." 794# 795# code: INTEL-8001-J5 796# keys: fault.cpu.intel.quickpath.mem_redundant 797# 798msgid "INTEL-8001-J5.type" 799msgstr "Fault" 800msgid "INTEL-8001-J5.severity" 801msgstr "Minor" 802msgid "INTEL-8001-J5.description" 803msgstr "Memory Mirroring lost due to error. Refer to %s for more information." 804msgid "INTEL-8001-J5.response" 805msgstr "There is no spare copy of memory" 806msgid "INTEL-8001-J5.impact" 807msgstr "There is a loss of hardware redundancy" 808msgid "INTEL-8001-J5.action" 809msgstr "Replace faulty dimm. Use 'fmadm faulty' to identify the dimm." 810# 811# code: INTEL-8001-KP 812# keys: fault.cpu.intel.quickpath.interconnect 813# 814msgid "INTEL-8001-KP.type" 815msgstr "Fault" 816msgid "INTEL-8001-KP.severity" 817msgstr "Major" 818msgid "INTEL-8001-KP.description" 819msgstr "Quickpath Deteced Error. Refer to %s for more information." 820msgid "INTEL-8001-KP.response" 821msgstr "System panic or reset by BIOS" 822msgid "INTEL-8001-KP.impact" 823msgstr "System may panic or be reset by BIOS" 824msgid "INTEL-8001-KP.action" 825msgstr "Schedule a repair procedure to check seating of proccessors" 826