xref: /illumos-gate/usr/src/cmd/fm/dicts/FMD.po (revision a38ddfee9c8c6b6c5a2947ff52fd2338362a4444)
1#
2# Copyright 2008 Sun Microsystems, Inc.  All rights reserved.
3# Use is subject to license terms.
4#
5# CDDL HEADER START
6#
7# The contents of this file are subject to the terms of the
8# Common Development and Distribution License (the "License").
9# You may not use this file except in compliance with the License.
10#
11# You can obtain a copy of the license at usr/src/OPENSOLARIS.LICENSE
12# or http://www.opensolaris.org/os/licensing.
13# See the License for the specific language governing permissions
14# and limitations under the License.
15#
16# When distributing Covered Code, include this CDDL HEADER in each
17# file and include the License file at usr/src/OPENSOLARIS.LICENSE.
18# If applicable, add the following below this CDDL HEADER, with the
19# fields enclosed by brackets "[]" replaced with your own identifying
20# information: Portions Copyright [yyyy] [name of copyright owner]
21#
22# CDDL HEADER END
23#
24#ident	"%Z%%M%	%I%	%E% SMI"
25#
26# DO NOT EDIT -- this file is generated by the Event Registry.
27#
28#
29# General-purpose messages
30#
31msgid "syslog-msgs-message-template"
32msgstr "SUNW-MSG-ID: %s, TYPE: %s, VER: 1, SEVERITY: %s\nEVENT-TIME: %s\nPLATFORM: %s, CSN: %s, HOSTNAME: %s\nSOURCE: %s, REV: %s\nEVENT-ID: %s\nDESC: %s\nAUTO-RESPONSE: %s\nIMPACT: %s\nREC-ACTION: %s\n"
33msgid "syslog-msgs-pointer"
34msgstr "\n...\nSee fmadm faulty -u <EVENT-ID> for full information.\n"
35
36#
37# Fault-related messages
38#
39#
40#
41# code: FMD-8000-0W
42# keys: defect.sunos.fmd.nosub
43#
44msgid "FMD-8000-0W.type"
45msgstr "Defect"
46msgid "FMD-8000-0W.severity"
47msgstr "Minor"
48msgid "FMD-8000-0W.description"
49msgstr "The Solaris Fault Manager received an event from a component to which no automated diagnosis software is currently subscribed.  Refer to %s for more information."
50msgid "FMD-8000-0W.response"
51msgstr "Error reports from the component will be logged for examination by Sun."
52msgid "FMD-8000-0W.impact"
53msgstr "Automated diagnosis and response for these events will not occur."
54msgid "FMD-8000-0W.action"
55msgstr "Run pkgchk -n SUNWfmd to ensure that fault management software is installed properly.  Contact Sun for support."
56#
57# code: FMD-8000-11
58# keys: defect.sunos.fmd.nodiagcode
59#
60msgid "FMD-8000-11.type"
61msgstr "Defect"
62msgid "FMD-8000-11.severity"
63msgstr "Minor"
64msgid "FMD-8000-11.description"
65msgstr "A Solaris Fault Manager component generated a diagnosis for which no message summary exists.  Refer to %s for more information."
66msgid "FMD-8000-11.response"
67msgstr "The diagnosis has been saved in the fault log for examination by Sun."
68msgid "FMD-8000-11.impact"
69msgstr "The fault log will need to be manually examined using fmdump(1M) in order to determine if any human response is required."
70msgid "FMD-8000-11.action"
71msgstr "Use fmdump -v -u <EVENT-ID> to view the diagnosis result.  Run pkgchk -n SUNWfmd to ensure that fault management software is installed properly."
72#
73# code: FMD-8000-2K
74# keys: defect.sunos.fmd.module
75#
76msgid "FMD-8000-2K.type"
77msgstr "Defect"
78msgid "FMD-8000-2K.severity"
79msgstr "Minor"
80msgid "FMD-8000-2K.description"
81msgstr "A Solaris Fault Manager component has experienced an error that required the module to be disabled.  Refer to %s for more information."
82msgid "FMD-8000-2K.response"
83msgstr "The module has been disabled.  Events destined for the module will be saved for manual diagnosis."
84msgid "FMD-8000-2K.impact"
85msgstr "Automated diagnosis and response for subsequent events associated with this module will not occur."
86msgid "FMD-8000-2K.action"
87msgstr "Use fmdump -v -u <EVENT-ID> to locate the module.  Use fmadm reset <module> to reset the module."
88#
89# code: FMD-8000-3F
90# keys: defect.sunos.fmd.config
91#
92msgid "FMD-8000-3F.type"
93msgstr "Defect"
94msgid "FMD-8000-3F.severity"
95msgstr "Minor"
96msgid "FMD-8000-3F.description"
97msgstr "A Solaris Fault Manager component could not load due to an erroroneous configuration file.  Refer to %s for more information."
98msgid "FMD-8000-3F.response"
99msgstr "The module has been disabled.  Events destined for the module will be saved for manual diagnosis."
100msgid "FMD-8000-3F.impact"
101msgstr "Automated diagnosis and response for subsequent events associated with this module will not occur."
102msgid "FMD-8000-3F.action"
103msgstr "Use fmdump -v -u <EVENT-ID> to locate the module.  Use fmadm load <module> to load the module after repairing its configuration."
104#
105# code: FMD-8000-4M
106# keys: list.repaired
107#
108msgid "FMD-8000-4M.type"
109msgstr "Repair"
110msgid "FMD-8000-4M.severity"
111msgstr "Minor"
112msgid "FMD-8000-4M.description"
113msgstr "All faults associated with an event id have been addressed.\n  Refer to %s for more information."
114msgid "FMD-8000-4M.response"
115msgstr "Some system components offlined because of the original fault may have been brought back online.\n"
116msgid "FMD-8000-4M.impact"
117msgstr "Performance degradation of the system due to the original fault may have been recovered.\n"
118msgid "FMD-8000-4M.action"
119msgstr "Use fmdump -v -u <EVENT-ID> to identify the repaired components."
120#
121# code: FMD-8000-58
122# keys: list.updated
123#
124msgid "FMD-8000-58.type"
125msgstr "Update"
126msgid "FMD-8000-58.severity"
127msgstr "Minor"
128msgid "FMD-8000-58.description"
129msgstr "Some faults associated with an event id have been addressed.\n  Refer to %s for more information."
130msgid "FMD-8000-58.response"
131msgstr "Some system components offlined because of the original fault may have been brought back online.\n"
132msgid "FMD-8000-58.impact"
133msgstr "Performance degradation of the system due to the original fault may have been recovered.\n"
134msgid "FMD-8000-58.action"
135msgstr "Use fmadm faulty to identify the repaired components, and any suspects that still need to be repaired.\n"
136#
137# code: FMD-8000-6U
138# keys: list.resolved
139#
140msgid "FMD-8000-6U.type"
141msgstr "Resolved"
142msgid "FMD-8000-6U.severity"
143msgstr "Minor"
144msgid "FMD-8000-6U.description"
145msgstr "All faults associated with an event id have been addressed.\n  Refer to %s for more information."
146msgid "FMD-8000-6U.response"
147msgstr "All system components offlined because of the original fault have been brought back online.\n"
148msgid "FMD-8000-6U.impact"
149msgstr "Performance degradation of the system due to the original fault has been recovered.\n"
150msgid "FMD-8000-6U.action"
151msgstr "Use fmdump -v -u <EVENT-ID> to identify the repaired components.\n"
152