1# 2# Copyright 2008 Sun Microsystems, Inc. All rights reserved. 3# Use is subject to license terms. 4# Copyright 2016 Nexenta Systems, Inc. All rights reserved. 5# 6# CDDL HEADER START 7# 8# The contents of this file are subject to the terms of the 9# Common Development and Distribution License (the "License"). 10# You may not use this file except in compliance with the License. 11# 12# You can obtain a copy of the license at usr/src/OPENSOLARIS.LICENSE 13# or http://www.opensolaris.org/os/licensing. 14# See the License for the specific language governing permissions 15# and limitations under the License. 16# 17# When distributing Covered Code, include this CDDL HEADER in each 18# file and include the License file at usr/src/OPENSOLARIS.LICENSE. 19# If applicable, add the following below this CDDL HEADER, with the 20# fields enclosed by brackets "[]" replaced with your own identifying 21# information: Portions Copyright [yyyy] [name of copyright owner] 22# 23# CDDL HEADER END 24# 25# 26# DO NOT EDIT -- this file is generated by the Event Registry. 27# 28# 29# code: DISK-8000-0X 30# keys: fault.io.disk.predictive-failure 31# 32msgid "DISK-8000-0X.type" 33msgstr "Fault" 34msgid "DISK-8000-0X.severity" 35msgstr "Major" 36msgid "DISK-8000-0X.description" 37msgstr "SMART health-monitoring firmware reported that a disk\nfailure is imminent.\n Refer to %s for more information." 38msgid "DISK-8000-0X.response" 39msgstr "None.\n" 40msgid "DISK-8000-0X.impact" 41msgstr "It is likely that the continued operation of\nthis disk will result in data loss.\n" 42msgid "DISK-8000-0X.action" 43msgstr "Schedule a repair procedure to replace the affected disk.\nUse fmdump -v -u <EVENT_ID> to identify the disk.\n" 44# 45# code: DISK-8000-12 46# keys: fault.io.disk.over-temperature 47# 48msgid "DISK-8000-12.type" 49msgstr "Fault" 50msgid "DISK-8000-12.severity" 51msgstr "Major" 52msgid "DISK-8000-12.description" 53msgstr "A disk's temperature exceeded the limits established by\nits manufacturer.\n Refer to %s for more information." 54msgid "DISK-8000-12.response" 55msgstr "None.\n" 56msgid "DISK-8000-12.impact" 57msgstr "Performance degradation is likely and continued disk operation\nbeyond the temperature threshold can result in disk\ndamage and potential data loss.\n" 58msgid "DISK-8000-12.action" 59msgstr "Ensure that the system is properly cooled, that all fans are\nfunctional, and that there are no obstructions of airflow to the affected\ndisk.\n" 60# 61# code: DISK-8000-2J 62# keys: fault.io.disk.self-test-failure 63# 64msgid "DISK-8000-2J.type" 65msgstr "Fault" 66msgid "DISK-8000-2J.severity" 67msgstr "Critical" 68msgid "DISK-8000-2J.description" 69msgstr "One or more disk self tests failed.\n Refer to %s for more information." 70msgid "DISK-8000-2J.response" 71msgstr "None.\n" 72msgid "DISK-8000-2J.impact" 73msgstr "The disk has failed.\n" 74msgid "DISK-8000-2J.action" 75msgstr "Schedule a repair procedure to replace the affected disk.\nUse fmdump -v -u <EVENT_ID> to identify the disk.\n" 76# 77# code: DISK-8000-3E 78# keys: fault.io.scsi.cmd.disk.dev.rqs.derr 79# 80msgid "DISK-8000-3E.type" 81msgstr "Fault" 82msgid "DISK-8000-3E.severity" 83msgstr "Critical" 84msgid "DISK-8000-3E.description" 85msgstr "A non-recoverable hardware failure was detected by the device while performing a command.\n Refer to %s for more information." 86msgid "DISK-8000-3E.response" 87msgstr "The device may be offlined or degraded.\n" 88msgid "DISK-8000-3E.impact" 89msgstr "The device has failed. The service may have been lost or degraded.\n" 90msgid "DISK-8000-3E.action" 91msgstr "Ensure that the latest drivers and patches are installed. Schedule a repair procedure to replace the affected\ndevice. Use 'fmadm faulty' to find the affected disk.\n" 92# 93# code: DISK-8000-4Q 94# keys: fault.io.scsi.cmd.disk.dev.rqs.merr 95# 96msgid "DISK-8000-4Q.type" 97msgstr "Fault" 98msgid "DISK-8000-4Q.severity" 99msgstr "Critical" 100msgid "DISK-8000-4Q.description" 101msgstr "The command was terminated with a non-recovered error condition that may have been caused by a flaw in the media or an error in the recorded data. \n Refer to %s for more information." 102msgid "DISK-8000-4Q.response" 103msgstr "The device may be offlined or degraded.\n" 104msgid "DISK-8000-4Q.impact" 105msgstr "It is likely that continued operation will result in data corruption, which may eventually cause the loss of service or the service degradation.\n" 106msgid "DISK-8000-4Q.action" 107msgstr "Schedule a repair procedure to replace the affected device. Use 'fmadm faulty' to find the affected disk.\n" 108# 109# code: DISK-8000-8D 110# keys: fault.io.disk.ssm-wearout 111# 112msgid "DISK-8000-8D.type" 113msgstr "Fault" 114msgid "DISK-8000-8D.severity" 115msgstr "Major" 116msgid "DISK-8000-8D.description" 117msgstr "A solid state media device is nearing end of life as projected by the manufacturer." 118msgid "DISK-8000-8D.response" 119msgstr "None." 120msgid "DISK-8000-8D.impact" 121msgstr "Performance degradation is likely and continued operation of this device will cause drive failure and potential data loss." 122msgid "DISK-8000-8D.action" 123msgstr "Schedule a repair procedure to replace the affected drive.\nUse fmdump -V -u <EVENT_ID> to identify the drive." 124