13c6bf4efSScott Long.\" Copyright (c) 2008, 2009 Yahoo!, Inc. 23c6bf4efSScott Long.\" All rights reserved. 33c6bf4efSScott Long.\" 43c6bf4efSScott Long.\" Redistribution and use in source and binary forms, with or without 53c6bf4efSScott Long.\" modification, are permitted provided that the following conditions 63c6bf4efSScott Long.\" are met: 73c6bf4efSScott Long.\" 1. Redistributions of source code must retain the above copyright 83c6bf4efSScott Long.\" notice, this list of conditions and the following disclaimer. 93c6bf4efSScott Long.\" 2. Redistributions in binary form must reproduce the above copyright 103c6bf4efSScott Long.\" notice, this list of conditions and the following disclaimer in the 113c6bf4efSScott Long.\" documentation and/or other materials provided with the distribution. 123c6bf4efSScott Long.\" 3. The names of the authors may not be used to endorse or promote 133c6bf4efSScott Long.\" products derived from this software without specific prior written 143c6bf4efSScott Long.\" permission. 153c6bf4efSScott Long.\" 163c6bf4efSScott Long.\" THIS SOFTWARE IS PROVIDED BY THE AUTHOR AND CONTRIBUTORS ``AS IS'' AND 173c6bf4efSScott Long.\" ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE 183c6bf4efSScott Long.\" IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE 193c6bf4efSScott Long.\" ARE DISCLAIMED. IN NO EVENT SHALL THE AUTHOR OR CONTRIBUTORS BE LIABLE 203c6bf4efSScott Long.\" FOR ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL 213c6bf4efSScott Long.\" DAMAGES (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS 223c6bf4efSScott Long.\" OR SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION) 233c6bf4efSScott Long.\" HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT 243c6bf4efSScott Long.\" LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY 253c6bf4efSScott Long.\" OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF 263c6bf4efSScott Long.\" SUCH DAMAGE. 273c6bf4efSScott Long.\" 283c6bf4efSScott Long.\" $FreeBSD$ 293c6bf4efSScott Long.\" 30d78c3fa1SScott Long.Dd August 16, 2009 31b1f3db02SScott Long.Dt MFIUTIL 8 323c6bf4efSScott Long.Os 333c6bf4efSScott Long.Sh NAME 343c6bf4efSScott Long.Nm mfiutil 353c6bf4efSScott Long.Nd Utility for managing LSI MegaRAID SAS controllers 363c6bf4efSScott Long.Sh SYNOPSIS 373c6bf4efSScott Long.Nm 383c6bf4efSScott Long.Cm version 393c6bf4efSScott Long.Nm 403c6bf4efSScott Long.Op Fl u Ar unit 413c6bf4efSScott Long.Cm show adapter 423c6bf4efSScott Long.Nm 433c6bf4efSScott Long.Op Fl u Ar unit 443c6bf4efSScott Long.Cm show battery 453c6bf4efSScott Long.Nm 463c6bf4efSScott Long.Op Fl u Ar unit 473c6bf4efSScott Long.Cm show config 483c6bf4efSScott Long.Nm 493c6bf4efSScott Long.Op Fl u Ar unit 503c6bf4efSScott Long.Cm show drives 513c6bf4efSScott Long.Nm 523c6bf4efSScott Long.Op Fl u Ar unit 533c6bf4efSScott Long.Cm show events 543c6bf4efSScott Long.Op Fl c Ar class 553c6bf4efSScott Long.Op Fl l Ar locale 563c6bf4efSScott Long.Op Fl n Ar count 573c6bf4efSScott Long.Op Fl v 583c6bf4efSScott Long.Op Ar start Op Ar stop 593c6bf4efSScott Long.Nm 603c6bf4efSScott Long.Op Fl u Ar unit 613c6bf4efSScott Long.Cm show firmware 623c6bf4efSScott Long.Nm 633c6bf4efSScott Long.Op Fl u Ar unit 643c6bf4efSScott Long.Cm show logstate 653c6bf4efSScott Long.Nm 663c6bf4efSScott Long.Op Fl u Ar unit 673c6bf4efSScott Long.Cm show patrol 683c6bf4efSScott Long.Nm 693c6bf4efSScott Long.Op Fl u Ar unit 703c6bf4efSScott Long.Cm show volumes 713c6bf4efSScott Long.Nm 723c6bf4efSScott Long.Op Fl u Ar unit 733c6bf4efSScott Long.Cm fail Ar drive 743c6bf4efSScott Long.Nm 753c6bf4efSScott Long.Op Fl u Ar unit 763c6bf4efSScott Long.Cm good Ar drive 773c6bf4efSScott Long.Nm 783c6bf4efSScott Long.Op Fl u Ar unit 793c6bf4efSScott Long.Cm rebuild Ar drive 803c6bf4efSScott Long.Nm 813c6bf4efSScott Long.Op Fl u Ar unit 823c6bf4efSScott Long.Cm drive progress Ar drive 833c6bf4efSScott Long.Nm 843c6bf4efSScott Long.Op Fl u Ar unit 853c6bf4efSScott Long.Cm drive clear Ar drive Brq "start | stop" 863c6bf4efSScott Long.Nm 873c6bf4efSScott Long.Op Fl u Ar unit 883c6bf4efSScott Long.Cm start rebuild Ar drive 893c6bf4efSScott Long.Nm 903c6bf4efSScott Long.Op Fl u Ar unit 913c6bf4efSScott Long.Cm abort rebuild Ar drive 923c6bf4efSScott Long.Nm 933c6bf4efSScott Long.Op Fl u Ar unit 943c6bf4efSScott Long.Cm locate Ar drive Brq "on | off" 953c6bf4efSScott Long.Nm 963c6bf4efSScott Long.Op Fl u Ar unit 973c6bf4efSScott Long.Cm cache Ar volume Op Ar setting Op Ar value 983c6bf4efSScott Long.Nm 993c6bf4efSScott Long.Op Fl u Ar unit 1003c6bf4efSScott Long.Cm name Ar volume Ar name 1013c6bf4efSScott Long.Nm 1023c6bf4efSScott Long.Op Fl u Ar unit 1033c6bf4efSScott Long.Cm volume progress Ar volume 1043c6bf4efSScott Long.Nm 1053c6bf4efSScott Long.Op Fl u Ar unit 1063c6bf4efSScott Long.Cm clear 1073c6bf4efSScott Long.Nm 1083c6bf4efSScott Long.Op Fl u Ar unit 1093c6bf4efSScott Long.Cm create Ar type 1103c6bf4efSScott Long.Op Fl v 1113c6bf4efSScott Long.Op Fl s Ar stripe_size 1123c6bf4efSScott Long.Ar drive Ns Op \&, Ns Ar drive Ns Op ",..." 1133c6bf4efSScott Long.Op Ar drive Ns Op \&, Ns Ar drive Ns Op ",..." 1143c6bf4efSScott Long.Nm 1153c6bf4efSScott Long.Op Fl u Ar unit 1163c6bf4efSScott Long.Cm delete Ar volume 1173c6bf4efSScott Long.Nm 1183c6bf4efSScott Long.Op Fl u Ar unit 1193c6bf4efSScott Long.Cm add Ar drive Op Ar volume 1203c6bf4efSScott Long.Nm 1213c6bf4efSScott Long.Op Fl u Ar unit 1223c6bf4efSScott Long.Cm remove Ar drive 1233c6bf4efSScott Long.Nm 1243c6bf4efSScott Long.Op Fl u Ar unit 1253c6bf4efSScott Long.Cm start patrol 1263c6bf4efSScott Long.Nm 1273c6bf4efSScott Long.Op Fl u Ar unit 1283c6bf4efSScott Long.Cm stop patrol 1293c6bf4efSScott Long.Nm 1303c6bf4efSScott Long.Op Fl u Ar unit 1313c6bf4efSScott Long.Cm patrol Ar command Op Ar interval Op Ar start 1323c6bf4efSScott Long.Nm 1333c6bf4efSScott Long.Op Fl u Ar unit 1343c6bf4efSScott Long.Cm flash Ar file 1353c6bf4efSScott Long.Sh DESCRIPTION 1363c6bf4efSScott LongThe 1373c6bf4efSScott Long.Nm 1383c6bf4efSScott Longutility can be used to display or modify various parameters on LSI 1393c6bf4efSScott LongMegaRAID SAS RAID controllers. 1403c6bf4efSScott LongEach invocation of 1413c6bf4efSScott Long.Nm 1423c6bf4efSScott Longconsists of zero or more global options followed by a command. 1433c6bf4efSScott LongCommands may support additional optional or required arguments after the 1443c6bf4efSScott Longcommand. 1453c6bf4efSScott Long.Pp 1463c6bf4efSScott LongCurrently one global option is supported: 1473c6bf4efSScott Long.Bl -tag -width indent 1483c6bf4efSScott Long.It Fl u Ar unit 1493c6bf4efSScott Long.Ar unit 1503c6bf4efSScott Longspecifies the unit of the controller to work with. 1513c6bf4efSScott LongIf no unit is specified, 1523c6bf4efSScott Longthen unit 0 is used. 1533c6bf4efSScott Long.El 1543c6bf4efSScott Long.Pp 1553c6bf4efSScott LongVolumes may be specified in two forms. 1563c6bf4efSScott LongFirst, 1573c6bf4efSScott Longa volume may be identified by its target ID. 1583c6bf4efSScott LongSecond, 1593c6bf4efSScott Longon the volume may be specified by the corresponding 1603c6bf4efSScott Long.Em mfidX 1613c6bf4efSScott Longdevice, 1623c6bf4efSScott Longsuch as 1633c6bf4efSScott Long.Em mfid0 . 1643c6bf4efSScott Long.Pp 1653c6bf4efSScott LongDrives may be specified in two forms. 1663c6bf4efSScott LongFirst, 1673c6bf4efSScott Longa drive may be identified by its device ID. 1683c6bf4efSScott LongThe device ID for configured drives can be found in 1693c6bf4efSScott Long.Cm show config . 1703c6bf4efSScott LongSecond, 1713c6bf4efSScott Longa drive may be identified by its location as 1723c6bf4efSScott Long.Sm off 1733c6bf4efSScott Long.Op E Ar xx Ns \&: 1743c6bf4efSScott Long.Li S Ns Ar yy 1753c6bf4efSScott Long.Sm on 1763c6bf4efSScott Longwhere 1773c6bf4efSScott Long.Ar xx 1783c6bf4efSScott Longis the enclosure 1793c6bf4efSScott Longand 1803c6bf4efSScott Long.Ar yy 1813c6bf4efSScott Longis the slot for each drive as displayed in 1823c6bf4efSScott Long.Cm show drives . 1833c6bf4efSScott Long.Pp 1843c6bf4efSScott LongThe 1853c6bf4efSScott Long.Nm 1863c6bf4efSScott Longutility supports several different groups of commands. 1873c6bf4efSScott LongThe first group of commands provide information about the controller, 1883c6bf4efSScott Longthe volumes it manages, and the drives it controls. 1893c6bf4efSScott LongThe second group of commands are used to manage the physical drives 1903c6bf4efSScott Longattached to the controller. 1913c6bf4efSScott LongThe third group of commands are used to manage the logical volumes 1923c6bf4efSScott Longmanaged by the controller. 1933c6bf4efSScott LongThe fourth group of commands are used to manage the drive configuration for 1943c6bf4efSScott Longthe controller. 1953c6bf4efSScott LongThe fifth group of commands are used to manage controller-wide operations. 1963c6bf4efSScott Long.Pp 1973c6bf4efSScott LongThe informational commands include: 1983c6bf4efSScott Long.Bl -tag -width indent 1993c6bf4efSScott Long.It Cm version 2003c6bf4efSScott LongDisplays the version of 2013c6bf4efSScott Long.Nm . 2023c6bf4efSScott Long.It Cm show adapter 2033c6bf4efSScott LongDisplays information about the RAID controller such as the model number. 2043c6bf4efSScott Long.It Cm show battery 2053c6bf4efSScott LongDisplays information about the battery from the battery backup unit. 2063c6bf4efSScott Long.It Cm show config 2073c6bf4efSScott LongDisplays the volume and drive configuration for the controller. 2083c6bf4efSScott LongEach array is listed along with the physical drives the array is built from. 2093c6bf4efSScott LongEach volume is listed along with the arrays that the volume spans. 2103c6bf4efSScott LongIf any hot spare drives are configured, then they are listed as well. 2113c6bf4efSScott Long.It Cm show drives 2123c6bf4efSScott LongLists all of the physical drives attached to the controller. 2133c6bf4efSScott Long.It Xo Cm show events 2143c6bf4efSScott Long.Op Fl c Ar class 2153c6bf4efSScott Long.Op Fl l Ar locale 2163c6bf4efSScott Long.Op Fl n Ar count 2173c6bf4efSScott Long.Op Fl v 2183c6bf4efSScott Long.Op Ar start Op Ar stop 2193c6bf4efSScott Long.Xc 2203c6bf4efSScott LongDisplay entries from the controller's event log. 2213c6bf4efSScott LongThe controller maintains a circular buffer of events. 2223c6bf4efSScott LongEach event is tagged with a class and locale. 2233c6bf4efSScott Long.Pp 2243c6bf4efSScott LongThe 2253c6bf4efSScott Long.Ar class 2263c6bf4efSScott Longparameter limits the output to entries at the specified class or higher. 2273c6bf4efSScott LongThe default class is 2283c6bf4efSScott Long.Dq warn . 2293c6bf4efSScott LongThe available classes from lowest priority to highest are: 2303c6bf4efSScott Long.Bl -tag -width -indent 2313c6bf4efSScott Long.It Cm debug 2323c6bf4efSScott LongDebug messages. 2333c6bf4efSScott Long.It Cm progress 2343c6bf4efSScott LongPeriodic progress updates for long-running operations such as background 2353c6bf4efSScott Longinitializations, array rebuilds, or patrol reads. 2363c6bf4efSScott Long.It Cm info 2373c6bf4efSScott LongInformational messages such as drive insertions and volume creations. 2383c6bf4efSScott Long.It Cm warn 2393c6bf4efSScott LongIndicates that some component may be close to failing. 2403c6bf4efSScott Long.It Cm crit 2413c6bf4efSScott LongA component has failed, but no data is lost. 2423c6bf4efSScott LongFor example, a volume becoming degraded due to a drive failure. 2433c6bf4efSScott Long.It Cm fatal 2443c6bf4efSScott LongA component has failed resulting in data loss. 2453c6bf4efSScott Long.It Cm dead 2463c6bf4efSScott LongThe controller itself has died. 2473c6bf4efSScott Long.El 2483c6bf4efSScott Long.Pp 2493c6bf4efSScott LongThe 2503c6bf4efSScott Long.Ar locale 2513c6bf4efSScott Longparameter limits the output to entries for the specified part of the controller. 2523c6bf4efSScott LongThe default locale is 2533c6bf4efSScott Long.Dq all . 2543c6bf4efSScott LongThe available locales are 2553c6bf4efSScott Long.Dq volume , 2563c6bf4efSScott Long.Dq drive , 257*f6ac2391SJoel Dahl.Dq enclosure , 2583c6bf4efSScott Long.Dq battery , 2593c6bf4efSScott Long.Dq sas , 2603c6bf4efSScott Long.Dq controller , 2613c6bf4efSScott Long.Dq config , 2623c6bf4efSScott Long.Dq cluster , 2633c6bf4efSScott Longand 2643c6bf4efSScott Long.Dq all . 2653c6bf4efSScott Long.Pp 2663c6bf4efSScott LongThe 2673c6bf4efSScott Long.Ar count 2683c6bf4efSScott Longparameter is a debugging aid that specifies the number of events to fetch from 2693c6bf4efSScott Longthe controller for each low-level request. 2703c6bf4efSScott LongThe default is 15 events. 2713c6bf4efSScott Long.Pp 2723c6bf4efSScott LongBy default, matching event log entries from the previous shutdown up to the 2733c6bf4efSScott Longpresent are displayed. This range can be adjusted via the 2743c6bf4efSScott Long.Ar start 2753c6bf4efSScott Longand 2763c6bf4efSScott Long.Ar stop 2773c6bf4efSScott Longparameters. 2783c6bf4efSScott LongEach of these parameters can either be specified as a log entry number or as 2793c6bf4efSScott Longone of the following aliases: 2803c6bf4efSScott Long.Bl -tag -width -indent 2813c6bf4efSScott Long.It Cm newest 2823c6bf4efSScott LongThe newest entry in the event log. 2833c6bf4efSScott Long.It Cm oldest 2843c6bf4efSScott LongThe oldest entry in the event log. 2853c6bf4efSScott Long.It Cm clear 2863c6bf4efSScott LongThe first entry since the event log was cleared. 2873c6bf4efSScott Long.It Cm shutdown 2883c6bf4efSScott LongThe entry in the event log corresponding to the last time the controller was 2893c6bf4efSScott Longcleanly shut down. 2903c6bf4efSScott Long.It Cm boot 2913c6bf4efSScott LongThe entry in the event log corresponding to the most recent boot. 2923c6bf4efSScott Long.El 2933c6bf4efSScott Long.It Cm show firmware 2943c6bf4efSScott LongLists all of the firmware images present on the controller. 2953c6bf4efSScott Long.It Cm show logstate 2963c6bf4efSScott LongDisplay the various sequence numbers associated with the event log. 2973c6bf4efSScott Long.It Cm show patrol 2983c6bf4efSScott LongDisplay the status of the controller's patrol read operation. 2993c6bf4efSScott Long.It Cm show volumes 3003c6bf4efSScott LongLists all of the logical volumes managed by the controller. 3013c6bf4efSScott Long.El 3023c6bf4efSScott Long.Pp 3033c6bf4efSScott LongThe physical drive management commands include: 3043c6bf4efSScott Long.Bl -tag -width indent 3053c6bf4efSScott Long.It Cm fail Ar drive 3063c6bf4efSScott LongMark 3073c6bf4efSScott Long.Ar drive 3083c6bf4efSScott Longas failed. 3093c6bf4efSScott Long.Ar Drive 3103c6bf4efSScott Longmust be an online drive that is part of an array. 3113c6bf4efSScott Long.It Cm good Ar drive 3123c6bf4efSScott LongMark 3133c6bf4efSScott Long.Ar drive 3143c6bf4efSScott Longas an unconfigured good drive. 3153c6bf4efSScott Long.Ar Drive 3163c6bf4efSScott Longmust not be part of an existing array. 3173c6bf4efSScott Long.It Cm rebuild Ar drive 3183c6bf4efSScott LongMark a failed 3193c6bf4efSScott Long.Ar drive 3203c6bf4efSScott Longthat is still part of an array as a good drive suitable for a rebuild. 3213c6bf4efSScott LongThe firmware should kick off an array rebuild on its own if a failed drive 3223c6bf4efSScott Longis marked as a rebuild drive. 3233c6bf4efSScott Long.It Cm drive progress Ar drive 3243c6bf4efSScott LongReport the current progress and estimated completion time of drive operations 3253c6bf4efSScott Longsuch as rebuilds or patrol reads. 3263c6bf4efSScott Long.It Cm drive clear Ar drive Brq "start | stop" 3273c6bf4efSScott LongStart or stop the writing of all 0x00 characters to a drive. 3283c6bf4efSScott Long.It Cm start rebuild Ar drive 3293c6bf4efSScott LongManually start a rebuild on 3303c6bf4efSScott Long.Ar drive . 3313c6bf4efSScott Long.It Cm abort rebuild Ar drive 3323c6bf4efSScott LongAbort an in-progress rebuild operation on 3333c6bf4efSScott Long.Ar drive . 3343c6bf4efSScott LongIt can be resumed with the 3353c6bf4efSScott Long.Cm start rebuild 3363c6bf4efSScott Longcommand. 3373c6bf4efSScott Long.It Cm locate Ar drive Brq "on | off" 3383c6bf4efSScott LongChange the state of the external LED associated with 3393c6bf4efSScott Long.Ar drive . 3403c6bf4efSScott Long.El 3413c6bf4efSScott Long.Pp 3423c6bf4efSScott LongThe logical volume management commands include: 3433c6bf4efSScott Long.Bl -tag -width indent 3443c6bf4efSScott Long.It Cm cache Ar volume Op Ar setting Op Ar value 3453c6bf4efSScott LongIf no 3463c6bf4efSScott Long.Ar setting 3473c6bf4efSScott Longargument is supplied, then the current cache policy for 3483c6bf4efSScott Long.Ar volume 3493c6bf4efSScott Longis displayed; 3503c6bf4efSScott Longotherwise, 3513c6bf4efSScott Longthe cache policy for 3523c6bf4efSScott Long.Ar volume 3533c6bf4efSScott Longis modified. 3543c6bf4efSScott LongThe optional 3553c6bf4efSScott Long.Ar setting 3563c6bf4efSScott Longargument can be one of the following values: 3573c6bf4efSScott Long.Bl -tag -width indent 3583c6bf4efSScott Long.It Cm enable 3593c6bf4efSScott LongEnable caching for both read and write I/O operations. 3603c6bf4efSScott Long.It Cm disable 3613c6bf4efSScott LongDisable caching for both read and write I/O operations. 3623c6bf4efSScott Long.It Cm reads 3633c6bf4efSScott LongEnable caching only for read I/O operations. 3643c6bf4efSScott Long.It Cm writes 3653c6bf4efSScott LongEnable caching only for write I/O operations. 3663c6bf4efSScott Long.It Cm write-back 3673c6bf4efSScott LongUse write-back policy for cached writes. 3683c6bf4efSScott Long.It Cm write-through 3693c6bf4efSScott LongUse write-through policy for cached writes. 3703c6bf4efSScott Long.It Cm read-ahead Op Ar value 3713c6bf4efSScott LongSet the read ahead policy for cached reads. 3723c6bf4efSScott LongThe 3733c6bf4efSScott Long.Ar value 3743c6bf4efSScott Longargument can be set to either 3753c6bf4efSScott Long.Dq none , 3763c6bf4efSScott Long.Dq adaptive , 3773c6bf4efSScott Longor 3783c6bf4efSScott Long.Dq always . 3793c6bf4efSScott Long.It Cm write-cache Op Ar value 3803c6bf4efSScott LongControl the write caches on the physical drives backing 3813c6bf4efSScott Long.Ar volume . 3823c6bf4efSScott LongThe 3833c6bf4efSScott Long.Ar value 3843c6bf4efSScott Longargument can be set to either 3853c6bf4efSScott Long.Dq disable , 3863c6bf4efSScott Long.Dq enable , 3873c6bf4efSScott Longor 3883c6bf4efSScott Long.Dq default . 3893c6bf4efSScott Long.Pp 3903c6bf4efSScott LongIn general this setting should be left disabled to avoid data loss when the 3913c6bf4efSScott Longphysical drives lose power. 3923c6bf4efSScott LongThe battery backup of the RAID controller does not save data in the write 3933c6bf4efSScott Longcaches of the physical drives. 3943c6bf4efSScott Long.El 3953c6bf4efSScott Long.It Cm name Ar volume Ar name 3963c6bf4efSScott LongSets the name of 3973c6bf4efSScott Long.Ar volume 3983c6bf4efSScott Longto 3993c6bf4efSScott Long.Ar name . 4003c6bf4efSScott Long.It Cm volume progress Ar volume 4013c6bf4efSScott LongReport the current progress and estimated completion time of volume operations 4023c6bf4efSScott Longsuch as consistency checks and initializations. 4033c6bf4efSScott Long.El 4043c6bf4efSScott Long.Pp 4053c6bf4efSScott LongThe configuration commands include: 4063c6bf4efSScott Long.Bl -tag -width indent 4073c6bf4efSScott Long.It Cm clear 4083c6bf4efSScott LongDelete the entire configuration including all volumes, arrays, and spares. 4093c6bf4efSScott Long.It Xo Cm create Ar type 4103c6bf4efSScott Long.Op Fl v 4113c6bf4efSScott Long.Op Fl s Ar stripe_size 4123c6bf4efSScott Long.Ar drive Ns Op \&, Ns Ar drive Ns Op ",..." 4133c6bf4efSScott Long.Op Ar drive Ns Op \&, Ns Ar drive Ns Op ",..." 4143c6bf4efSScott Long.Xc 4153c6bf4efSScott LongCreate a new volume. 4163c6bf4efSScott LongThe 4173c6bf4efSScott Long.Ar type 4183c6bf4efSScott Longspecifies the type of volume to create. 4193c6bf4efSScott LongCurrently supported types include: 4203c6bf4efSScott Long.Bl -tag -width indent 4213c6bf4efSScott Long.It Cm jbod 4223c6bf4efSScott LongCreates a RAID0 volume for each drive specified. 4233c6bf4efSScott LongEach drive must be specified as a separate argument. 4243c6bf4efSScott Long.It Cm raid0 4253c6bf4efSScott LongCreates one RAID0 volume spanning the drives listed in the single drive list. 4263c6bf4efSScott Long.It Cm raid1 4273c6bf4efSScott LongCreates one RAID1 volume spanning the drives listed in the single drive list. 4283c6bf4efSScott Long.It Cm raid5 4293c6bf4efSScott LongCreates one RAID5 volume spanning the drives listed in the single drive list. 4303c6bf4efSScott Long.It Cm raid6 4313c6bf4efSScott LongCreates one RAID6 volume spanning the drives listed in the single drive list. 4323c6bf4efSScott Long.It Cm raid10 4333c6bf4efSScott LongCreates one RAID10 volume spanning multiple RAID1 arrays. 4343c6bf4efSScott LongThe drives for each RAID1 array are specified as a single drive list. 4353c6bf4efSScott Long.It Cm raid50 4363c6bf4efSScott LongCreates one RAID50 volume spanning multiple RAID5 arrays. 4373c6bf4efSScott LongThe drives for each RAID5 array are specified as a single drive list. 4383c6bf4efSScott Long.It Cm raid60 4393c6bf4efSScott LongCreates one RAID60 volume spanning multiple RAID6 arrays. 4403c6bf4efSScott LongThe drives for each RAID6 array are specified as a single drive list. 4413c6bf4efSScott Long.It Cm concat 4423c6bf4efSScott LongCreates a single volume by concatenating all of the drives in the single drive 4433c6bf4efSScott Longlist. 4443c6bf4efSScott Long.El 4453c6bf4efSScott Long.Pp 4463c6bf4efSScott Long.Sy Note: 4473c6bf4efSScott LongNot all volume types are supported by all controllers. 4483c6bf4efSScott Long.Pp 4493c6bf4efSScott LongIf the 4503c6bf4efSScott Long.Fl v 4513c6bf4efSScott Longflag is specified after 4523c6bf4efSScott Long.Ar type , 4533c6bf4efSScott Longthen more verbose output will be enabled. 4543c6bf4efSScott LongCurrently this just provides notification as drives are added to arrays and 4553c6bf4efSScott Longarrays to volumes when building the configuration. 4563c6bf4efSScott Long.Pp 4573c6bf4efSScott LongThe 4583c6bf4efSScott Long.Fl s 4593c6bf4efSScott Long.Ar stripe_size 4603c6bf4efSScott Longparameter allows the stripe size of the array to be set. 4613c6bf4efSScott LongBy default a stripe size of 64K is used. 4623c6bf4efSScott LongValid values are 512 through 1M, though the MFI firmware may reject some 4633c6bf4efSScott Longvalues. 4643c6bf4efSScott Long.It Cm delete Ar volume 4653c6bf4efSScott LongDelete the volume 4663c6bf4efSScott Long.Ar volume . 4673c6bf4efSScott Long.It Cm add Ar drive Op Ar volume 4683c6bf4efSScott LongMark 4693c6bf4efSScott Long.Ar drive 4703c6bf4efSScott Longas a hot spare. 4713c6bf4efSScott Long.Ar Drive 4723c6bf4efSScott Longmust be in the unconfigured good state. 4733c6bf4efSScott LongIf 4743c6bf4efSScott Long.Ar volume 4753c6bf4efSScott Longis specified, 4763c6bf4efSScott Longthen the hot spare will be dedicated to arrays backing that volume. 4773c6bf4efSScott LongOtherwise, 4783c6bf4efSScott Long.Ar drive 4793c6bf4efSScott Longwill be used as a global hot spare backing all arrays for this controller. 4803c6bf4efSScott LongNote that 4813c6bf4efSScott Long.Ar drive 4823c6bf4efSScott Longmust be as large as the smallest drive in all of the arrays it is going to 4833c6bf4efSScott Longback. 4843c6bf4efSScott Long.It Cm remove Ar drive 4853c6bf4efSScott LongRemove the hot spare 4863c6bf4efSScott Long.Ar drive 4873c6bf4efSScott Longfrom service. 4883c6bf4efSScott LongIt will be placed in the unconfigured good state. 4893c6bf4efSScott Long.El 4903c6bf4efSScott Long.Pp 4913c6bf4efSScott LongThe controller management commands include: 4923c6bf4efSScott Long.Bl -tag -width indent 4933c6bf4efSScott Long.It Cm patrol Ar command Op Ar interval Op Ar start 4943c6bf4efSScott LongSet the patrol read operation mode. 4953c6bf4efSScott LongThe 4963c6bf4efSScott Long.Ar command 4973c6bf4efSScott Longargument can be one of the following values: 4983c6bf4efSScott Long.Bl -tag -width indent 4993c6bf4efSScott Long.It Cm disable 5003c6bf4efSScott LongDisable patrol reads. 5013c6bf4efSScott Long.It Cm auto 5023c6bf4efSScott LongEnable periodic patrol reads initiated by the firmware. 5033c6bf4efSScott LongThe optional 5043c6bf4efSScott Long.Ar interval 5053c6bf4efSScott Longargument specifies the interval in seconds between patrol reads. 506d4352d29SJoel DahlIf patrol reads should be run continuously, 5073c6bf4efSScott Longthen 5083c6bf4efSScott Long.Ar interval 5093c6bf4efSScott Longshould consist of the word 5103c6bf4efSScott Long.Dq continuously . 5113c6bf4efSScott LongThe optional 5123c6bf4efSScott Long.Ar start 5133c6bf4efSScott Longargument specifies a non-negative, relative start time for the next patrol read. 5143c6bf4efSScott LongIf an interval or start time is not specified, 5153c6bf4efSScott Longthen the existing setting will be used. 5163c6bf4efSScott Long.It Cm manual 5173c6bf4efSScott LongEnable manual patrol reads that are only initiated by the user. 5183c6bf4efSScott Long.El 5193c6bf4efSScott Long.It Cm start patrol 5203c6bf4efSScott LongStart a patrol read operation. 5213c6bf4efSScott Long.It Cm stop patrol 5223c6bf4efSScott LongStop a currently running patrol read operation. 5233c6bf4efSScott Long.It Cm flash Ar file 5243c6bf4efSScott LongUpdates the flash on the controller with the firmware stored in 5253c6bf4efSScott Long.Ar file . 5263c6bf4efSScott LongA reboot is required for the new firmware to take effect. 5273c6bf4efSScott Long.El 5283c6bf4efSScott Long.Sh EXAMPLES 5293c6bf4efSScott LongConfigure the cache for volume mfid0 to cache only writes: 5303c6bf4efSScott Long.Pp 5313c6bf4efSScott Long.Dl Nm Cm cache mfid0 writes 5323c6bf4efSScott Long.Dl Nm Cm cache mfid0 write-back 5333c6bf4efSScott Long.Pp 5343c6bf4efSScott LongCreate a RAID5 array spanning the first four disks in the second enclosure: 5353c6bf4efSScott Long.Pp 5363c6bf4efSScott Long.Dl Nm Cm create raid5 e1:s0,e1:s1,e1:s2,e1:s4 5373c6bf4efSScott Long.Pp 5383c6bf4efSScott LongConfigure the first three disks on a controller as JBOD: 5393c6bf4efSScott Long.Pp 5403c6bf4efSScott Long.Dl Nm Cm create jbod 0 1 2 5413c6bf4efSScott Long.Pp 5423c6bf4efSScott LongCreate a RAID10 volume that spans two arrays each of which contains two disks 5433c6bf4efSScott Longfrom two different enclosures: 5443c6bf4efSScott Long.Pp 5453c6bf4efSScott Long.Dl Nm Cm create raid10 e1:s0,e1:s1 e2:s0,e2:s1 5463c6bf4efSScott Long.Pp 5473c6bf4efSScott LongAdd drive with the device ID of 4 as a global hot spare: 5483c6bf4efSScott Long.Pp 5493c6bf4efSScott Long.Dl Nm Cm add 4 5503c6bf4efSScott Long.Pp 5513c6bf4efSScott LongAdd the drive in slot 2 in the main chassis as a hot spare for volume mfid0: 5523c6bf4efSScott Long.Pp 5533c6bf4efSScott Long.Dl Nm Cm add s2 mfid0 5543c6bf4efSScott Long.Pp 5553c6bf4efSScott LongConfigure the adapter to run periodic patrol reads once a week with the first 5563c6bf4efSScott Longpatrol read starting in 5 minutes: 5573c6bf4efSScott Long.Pp 5583c6bf4efSScott Long.Dl Nm Cm patrol auto 604800 300 5593c6bf4efSScott Long.Pp 5603c6bf4efSScott Long.Sh SEE ALSO 5613c6bf4efSScott Long.Xr mfi 4 562d78c3fa1SScott Long.Sh HISTORY 563d78c3fa1SScott LongThe 564d78c3fa1SScott Long.Nm 565d78c3fa1SScott Longutility first appeared in 566d78c3fa1SScott Long.Fx 8.0 . 567