xref: /freebsd/usr.bin/fetch/fetch.1 (revision d37ea99837e6ad50837fd9fe1771ddf1c3ba6002)
1.\"-
2.\" Copyright (c) 2000 Dag-Erling Co�dan Sm�rgrav
3.\" All rights reserved.
4.\" Portions Copyright (c) 1999 Massachusetts Institute of Technology; used
5.\" by permission.
6.\"
7.\" Redistribution and use in source and binary forms, with or without
8.\" modification, are permitted provided that the following conditions
9.\" are met:
10.\" 1. Redistributions of source code must retain the above copyright
11.\"    notice, this list of conditions and the following disclaimer
12.\"    in this position and unchanged.
13.\" 2. Redistributions in binary form must reproduce the above copyright
14.\"    notice, this list of conditions and the following disclaimer in the
15.\"    documentation and/or other materials provided with the distribution.
16.\" 3. The name of the author may not be used to endorse or promote products
17.\"    derived from this software without specific prior written permission.
18.\"
19.\" THIS SOFTWARE IS PROVIDED BY THE AUTHOR ``AS IS'' AND ANY EXPRESS OR
20.\" IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES
21.\" OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE DISCLAIMED.
22.\" IN NO EVENT SHALL THE AUTHOR BE LIABLE FOR ANY DIRECT, INDIRECT,
23.\" INCIDENTAL, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL DAMAGES (INCLUDING, BUT
24.\" NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES; LOSS OF USE,
25.\" DATA, OR PROFITS; OR BUSINESS INTERRUPTION) HOWEVER CAUSED AND ON ANY
26.\" THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT LIABILITY, OR TORT
27.\" (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY OUT OF THE USE OF
28.\" THIS SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE.
29.\"
30.\" $FreeBSD$
31.\"
32.Dd March 11, 2003
33.Dt FETCH 1
34.Os
35.Sh NAME
36.Nm fetch
37.Nd retrieve a file by Uniform Resource Locator
38.Sh SYNOPSIS
39.Nm
40.Op Fl 146AFMPRUadlmnpqrsv
41.Op Fl B Ar bytes
42.Op Fl S Ar bytes
43.Op Fl T Ar seconds
44.Op Fl N Ar file
45.Op Fl o Ar file
46.Op Fl w Ar seconds
47.Op Fl h Ar host
48.Op Fl c Ar dir
49.Op Fl f Ar file
50.Op Ar URL ...
51.Sh DESCRIPTION
52The
53.Nm
54utility provides a command-line interface to the
55.Xr fetch 3
56library.
57Its purpose is to retrieve the file(s) pointed to by the URL(s) on the
58command line.
59.Pp
60The following options are available:
61.Bl -tag -width Fl
62.It Fl \&1
63Stop and return exit code 0 at the first successfully retrieved file.
64.It Fl 4
65Forces
66.Nm
67to use IPv4 addresses only.
68.It Fl 6
69Forces
70.Nm
71to use IPv6 addresses only.
72.It Fl A
73Do not automatically follow ``temporary'' (302) redirects.
74Some broken Web sites will return a redirect instead of a not-found
75error when the requested object does not exist.
76.It Fl a
77Automatically retry the transfer upon soft failures.
78.It Fl B Ar bytes
79Specify the read buffer size in bytes.
80The default is 4096 bytes.
81Attempts to set a buffer size lower than this will be silently
82ignored.
83The number of reads actually performed is reported at verbosity level
84two or higher (see the
85.Fl v
86flag).
87.It Fl c Ar dir
88The file to retrieve is in directory
89.Ar dir
90on the remote host.
91This option is deprecated and is provided for backward compatibility
92only.
93.It Fl d
94Use a direct connection even if a proxy is configured.
95.It Fl F
96In combination with the
97.Fl r
98flag, forces a restart even if the local and remote files have
99different modification times.
100Implies
101.Fl R .
102.It Fl f Ar file
103The file to retrieve is named
104.Ar file
105on the remote host.
106This option is deprecated and is provided for backward compatibility
107only.
108.It Fl h Ar host
109The file to retrieve is located on the host
110.Ar host .
111This option is deprecated and is provided for backward compatibility
112only.
113.It Fl l
114If the target is a file-scheme URL, make a symbolic link to the target
115rather than trying to copy it.
116.It Fl M
117.It Fl m
118Mirror mode: if the file already exists locally and has the same size
119and modification time as the remote file, it will not be fetched.
120Note that the
121.Fl m
122and
123.Fl r
124flags are mutually exclusive.
125.It Fl N Ar file
126Use
127.Ar file
128instead of
129.Pa ~/.netrc
130to look up login names and passwords for FTP sites.
131See
132.Xr ftp 1
133for a description of the file format.
134This feature is experimental.
135.It Fl n
136Don't preserve the modification time of the transferred file.
137.It Fl o Ar file
138Set the output file name to
139.Ar file .
140By default, a ``pathname'' is extracted from the specified URI, and
141its basename is used as the name of the output file.
142A
143.Ar file
144argument of
145.Sq Li \&-
146indicates that results are to be directed to the standard output.
147.It Fl P
148.It Fl p
149Use passive FTP.
150This is useful if you are behind a firewall which blocks incoming
151connections.
152Try this flag if
153.Nm
154seems to hang when retrieving FTP URLs.
155.It Fl q
156Quiet mode.
157.It Fl R
158The output files are precious, and should not be deleted under any
159circumstances, even if the transfer failed or was incomplete.
160.It Fl r
161Restart a previously interrupted transfer.
162Note that the
163.Fl m
164and
165.Fl r
166flags are mutually exclusive.
167.It Fl S Ar bytes
168Require the file size reported by the server to match the specified
169value.
170If it does not, a message is printed and the file is not fetched.
171If the server does not support reporting file sizes, this option is
172ignored and the file is fetched unconditionally.
173.It Fl s
174Print the size in bytes of each requested file, without fetching it.
175.It Fl T Ar seconds
176Set timeout value to
177.Ar seconds .
178Overrides the environment variables
179.Ev FTP_TIMEOUT
180for FTP transfers or
181.Ev HTTP_TIMEOUT
182for HTTP transfers if set.
183.It Fl U
184When using passive FTP, allocate the port for the data connection from
185the low (default) port range.
186See
187.Xr ip 4
188for details on how to specify which port range this corresponds to.
189.It Fl v
190Increase verbosity level.
191.It Fl w Ar seconds
192When the
193.Fl a
194flag is specified, wait this many seconds between successive retries.
195.El
196.Pp
197If
198.Nm
199receives a
200.Dv SIGINFO
201signal (see the
202.Cm status
203argument for
204.Xr stty 1 ) ,
205the current transfer rate statistics will be written to the
206standard error output, in the same format as the standard completion
207message.
208.Sh DIAGNOSTICS
209The
210.Nm
211command returns zero on success, or one on failure.
212If multiple URLs are listed on the command line,
213.Nm
214will attempt to retrieve them each of them in turn, and return zero
215only if they were all successfully retrieved.
216.Sh ENVIRONMENT
217.Bl -tag -width HTTP_TIMEOUT
218.It Ev FTP_TIMEOUT
219maximum time, in seconds, to wait before aborting an FTP connection.
220.It Ev HTTP_TIMEOUT
221maximum time, in seconds, to wait before aborting an HTTP connection.
222.El
223.Pp
224All environment variables mentioned in the documentation for the
225.Xr fetch 3
226library are supported.
227A number of these are quite important to the proper operation of
228.Nm ;
229you are strongly encouraged to read
230.Xr fetch 3
231as well.
232.Sh SEE ALSO
233.Xr fetch 3
234.Sh HISTORY
235The
236.Nm
237command appeared in
238.Fx 2.1.5 .
239This implementation first appeared in
240.Fx 4.1 .
241.Sh AUTHORS
242.An -nosplit
243The original implementation of
244.Nm
245was done by
246.An Jean-Marc Zucconi Aq jmz@FreeBSD.org .
247It was extensively re-worked for
248.Fx 2.2
249by
250.An Garrett Wollman Aq wollman@FreeBSD.org ,
251and later completely rewritten to use the
252.Xr fetch 3
253library by
254.An Dag-Erling Sm\(/orgrav Aq des@FreeBSD.org .
255.Sh NOTES
256The
257.Fl b
258and
259.Fl t
260options are no longer supported and will generate warnings.
261They were workarounds for bugs in other OSes which this implementation
262does not trigger.
263.Pp
264One cannot both use the
265.Fl h ,
266.Fl c
267and
268.Fl f
269options and specify URLs on the command line.
270