xref: /freebsd/tools/test/stress2/misc/force9.sh (revision cc68614da8232d8baaca0ae0d0dd8f890f06623e)
1#!/bin/sh
2
3#
4# SPDX-License-Identifier: BSD-2-Clause-FreeBSD
5#
6# Copyright (c) 2021 Peter Holm <pho@FreeBSD.org>
7#
8# Redistribution and use in source and binary forms, with or without
9# modification, are permitted provided that the following conditions
10# are met:
11# 1. Redistributions of source code must retain the above copyright
12#    notice, this list of conditions and the following disclaimer.
13# 2. Redistributions in binary form must reproduce the above copyright
14#    notice, this list of conditions and the following disclaimer in the
15#    documentation and/or other materials provided with the distribution.
16#
17# THIS SOFTWARE IS PROVIDED BY THE AUTHOR AND CONTRIBUTORS ``AS IS'' AND
18# ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE
19# IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE
20# ARE DISCLAIMED.  IN NO EVENT SHALL THE AUTHOR OR CONTRIBUTORS BE LIABLE
21# FOR ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL
22# DAMAGES (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS
23# OR SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION)
24# HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT
25# LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY
26# OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF
27# SUCH DAMAGE.
28#
29
30# "mdconfig -o force" test scenario.
31# "panic: ffs_checkblk: cylinder group read failed" seen:
32# https://people.freebsd.org/~pho/stress/log/log0170.txt
33
34# "panic: softdep_update_inodeblock inconsistent ip ..." seen:
35# https://people.freebsd.org/~pho/stress/log/log0184.txt
36
37[ `id -u ` -ne 0 ] && echo "Must be root!" && exit 1
38. ../default.cfg
39
40log=/tmp/force7.sh.log
41mount | grep $mntpoint | grep -q /dev/md && umount -f $mntpoint
42mdconfig -l | grep -q md$mdstart &&  mdconfig -d -u $mdstart
43truncate -s 10g $diskimage
44mdconfig -a -t vnode -f $diskimage -u $mdstart
45flags=$newfs_flags
46echo "newfs $flags md$mdstart"
47newfs $flags md$mdstart > /dev/null 2>&1
48
49export TESTPROGS=`cd ..; find testcases/ -perm -1 -type f | \
50    egrep -Ev "/run/|/badcode/|/pty/|/shm/|/socket/|sysctl|tcp|thr|udp"`
51export runRUNTIME=3m
52export RUNDIR=$mntpoint/stressX
53start=`date +%s`
54while [ $((`date +%s` - start)) -lt $((15 * 60)) ]; do
55	mount /dev/md$mdstart $mntpoint
56	rm -fr $mntpoint/lost+found
57	chmod 777 $mntpoint
58
59	echo "Start tests"
60	su $testuser -c 'cd ..; ./testcases/run/run $TESTPROGS' > \
61	    /dev/null 2>&1 &
62
63	sleep `jot -r 1 60 180`
64	echo "Force destroy MD disk"
65	while mdconfig -l | grep -q md$mdstart; do
66		mdconfig -d -u $mdstart -o force || sleep 1
67	done
68	sleep 1
69	../tools/killall.sh
70	wait
71	n=0
72	while mount | grep $mntpoint | grep -q /dev/md; do
73		umount $mntpoint || sleep 1
74		[ $((n += 1)) -gt 300 ] && { echo FAIL; exit 1; }
75	done
76	mdconfig -a -t vnode -f $diskimage -u $mdstart
77	fsck_ffs -fyR /dev/md$mdstart > $log 2>&1; s=$?
78	[ $s -ne 0 ] && break
79	grep -Eq "IS CLEAN|MARKED CLEAN" $log || { s=100; break; }
80done
81if [ $s -eq 0 ]; then
82	mount /dev/md$mdstart $mntpoint
83	cp -R /usr/include $mntpoint
84	dd if=/dev/zero of=$mntpoint/big bs=1m count=10 status=none
85	find $mntpoint/* -delete
86	umount $mntpoint
87	mdconfig -d -u $mdstart
88	rm -f $diskimage $log
89else
90	cat $log
91fi
92exit $s
93